• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 18
  • Tagged with
  • 18
  • 18
  • 9
  • 9
  • 8
  • 7
  • 7
  • 7
  • 5
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Cultivo e composição química de Ora-pro-nóbis (Pereskia aculeata Mill.) sob déficit hídrico intermitente no solo

Queiroz, Carla Regina Amorim dos Anjos [UNESP] 29 August 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:01Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-08-29Bitstream added on 2014-06-13T20:01:25Z : No. of bitstreams: 1 queiroz_craa_dr_jabo.pdf: 1870663 bytes, checksum: 973278d0b0c76ef64d0f253e74e77f94 (MD5) / Plantas de Ora-pro-nóbis (OPN) foram submetidas, a partir de -5 kPa, à variação intermitente do potencial mátrico no substrato (PM) para até -10, -30, -50 ou -70 kPa (tratamentos). Com base no PM medido com tensiômetro de cápsula porosa e na curva de retenção de água do substrato foram aplicados os volumes de água por tratamento, em cada irrigação. Aos 140 dias após o transplantio a redução do PM provocou nas plantas estresse por déficit hídrico no solo em função da redução significativa do acúmulo de massa seca, mas o estresse foi de baixo a moderado uma vez que não ocorreu redução na área foliar e nem abscisão de folhas. Houve mudança na alocação de massa entre as partes, com maior redução em raízes, seguida de caules e folhas, além de redução na eficiência fotossintética, em função do decréscimo na área foliar específica e na razão de área foliar. Com menor PM a eficiência no uso da água foi maior, indicando bom potencial produtivo mesmo nessa condição; além de maior quantidade de células epidérmicas adaxiais, cujo tamanho foi reduzido. Os teores de macronutrientes em folhas seguiram a ordem Ca>N>K>Mg>P>S. Na planta toda, o teor de fósforo foi menor que os teores de N, K, Ca e Mg e maior que o S. Nas folhas de OPN a redução no PM de -10 kPa até -70 kPa, provocou redução no valor energético, extrato seco, fibra bruta e lipídeos, e aumento no teor de proteínas e carboidratos. Nos caules, resposta similar foi observada para o valor energético, extrato seco, proteínas e cinzas. Entretanto, para carboidratos e lipídeos, observou-se, respectivamente, redução e aumento dos teores em função da queda do PM. Os teores de lipídeos, cinzas e proteínas são maiores em folhas / Ora-pro-nóbis plants (OPN) were submitted from -5 kPa to -10, -30, -50 or -70 kPa (treatments) of intermittent variation of the matric potential (PM) in the substrate. According to the measured PM with porous cup tensiometer and the water retention curve of substrate, were applied at each irrigation time the volume of water required for each treatment. Up to 140 days after transplanting the PM decrease caused stress on plants by soil water deficit as evidenced by significant reduction in dry mass accumulation, but the stress was low to moderate since there was no significant reduction in leaf area and nor abscission of leaves. There was change in allocation mass between its parts, greater reduction in roots followed by stems and leaves, and photosynthetic efficiency reduction, due to decrease in specific leaf area and leaf area ratio. Under lower PM, the water use efficiency was greater, indicating good productive potential even in this condition, besides a greater number of adaxial epidermal cells, whose size were reduced. In leaves, macronutrient contents followed the order Ca>N>K>Mg>P>S. In whole plant, the phosphorus content was lower than the levels of N, K, Ca and Mg and higher than S. In OPN leaves, PM decrease from -10 kPa to -70 kPa caused a reduction in the energy value, dry extract, crude fiber and lipids, and increased protein and carbohydrates. In stems, similar response was observed for energy value, dry matter, protein and ash. However, for carbohydrates and lipids was observed, respectively, decreased and increased levels due to PM decrease. The stem/leaf reasons revealed that lipids, ash and protein levels are higher in leaves
2

Avaliação funcional de instrumentos de medição do potencial matricial da água do solo seco / Functional evaluation of instruments for measuring the water status of dry soil

Rodrigues, Thaís Tokashiki Tavares 31 July 2017 (has links)
Estudos sobre a dinâmica da água no solo não-saturado passam pela medição, estimativa e/ou previsão do potencial matricial ou do teor de água. Diante disso, o objetivo da presente proposta foi realizar testes e avaliações de três instrumentos com características distintas, capazes de medir o potencial matricial da água no solo seco, sendo eles: um medidor baseado no ponto de orvalho (WP4), um instrumento baseado na pressão (tensiômetro de polímero-PoT) e um instrumento baseado na capacitância elétrica (FDR EC-5). A análise foi realizada em três partes: 1. Avaliação do WP4 com amostras com potencial equilibrado na câmara de Richards ou secas ao ar; 2. Avaliação dos PoT e 3. Experimento comparativo entre instrumentos em colunas de solo. Nesses experimentos foram utilizados materiais de solos com texturas diferentes (um de textura argilosa, um de textura média e um de textura arenosa). Os experimentos foram conduzidos no Laboratório de Física de Solo do CENA/USP em Piracicaba-SP. Os resultados mostram que o FDR EC-5 apresentou bons resultados em relação ao método que foi definido como padrão (método gravimétrico), por mais que possua erros associados à curva de retenção. O WP4, que possui uma ampla faixa de leitura de 0 a -30000 m, não se apresentou muito preciso para solos úmidos (h > -70 m) devido ao seu procedimento de leitura. Para solos muito secos, no entanto, ele se apresenta como uma boa opção. O tensiômetro de polímero mede a pressão diretamente na faixa entre 0 a -150 m. Esse instrumento requer cuidados com o coeficiente de calibração, a verificação do limite individual de funcionamento e o contato entre a cápsula porosa do tensiômetro e o solo / Studies about unsaturated soil water dynamics involve the measurement or prediction of matric potential and/or soil water content. In this study, the objective was to test and evaluate three measurement devices able to measure matric potential in dry soil: a dew point based instrument (WP4), a pressure based instrument (polymer tensiometer - PoT) and an electromagnetic capacitance based instrument (FDR EC-5). The analysis was performed in three steps: 1. Evaluation of WP4 using soil samples in equilibrium with a pressure chamber or with surrounding air; 2. Evaluation of PoT and 3. Experiments to compare devices in soil columns. In these experiments three soil textures were used (clay texture, silt texture and sand texture). The experiments were conducted in the soil physics lab at CENA/Universidade de São Paulo, Piracicaba, Brazil. Results show that the FDR EC-5 performed well when compared to the (standard) gravimetric method, even though it includes errors associated with the retention curve. The WP4 device has a wide reading range of 0 to -30000 m, but is not accurate for saturated or moist soils (h > -70 m) due to its working principle. For very dry soils, however, it is a good option. The polymer tensiometers measure pressure directly and perform in a range between 0 to -150 m. This equipment showed to require special care regarding its calibration coefficient, verification of individual reading limit and the porous cap-soil contact
3

Avaliação de metodologias para obtenção dos parâmetros do modelo de Green-Ampt modificado por Mein e Larson / Methodologies evaluation for the obtention of parameters of the Green-Ampt model modified by Mein and Larson

Mello, Luis Tomás Azevedo de 11 August 2003 (has links)
Submitted by Marco Antônio de Ramos Chagas (mchagas@ufv.br) on 2017-02-16T17:47:33Z No. of bitstreams: 1 texto completo.pdf: 1472672 bytes, checksum: 051ad4e1d252fa2dd5d9dbd7c12c5d0e (MD5) / Made available in DSpace on 2017-02-16T17:47:33Z (GMT). No. of bitstreams: 1 texto completo.pdf: 1472672 bytes, checksum: 051ad4e1d252fa2dd5d9dbd7c12c5d0e (MD5) Previous issue date: 2003-08-11 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / Os modelos de infiltração embasados em princípios físicos são uma importante ferramenta a ser utilizada na modelagem hidrológica. O modelo de Green-Ampt é uma dessas ferramentas que vem sendo usada em diversas áreas relacionadas ao assunto. Entretanto, a adequação de seus parâmetros a solos brasileiros ainda precisa ser melhor estudada. Este trabalho teve por objetivo avaliar diferentes proposições de determinação dos parâmetros (umidade de saturação, θ s ; condutividade hidráulica, K e potencial matricial na frente de umedecimento, ψ f ) do modelo de Green-Ampt modificado por Mein e Larson (GAML) e sua aplicabilidade a diferentes condições de perfis homogêneo e heterogêneo de solo. O experimento foi conduzido em oito colunas de solo montadas com combinações distintas de horizontes (A, B e C) e massa específica (1,03 g/cm 3 e 1,23 g/cm 3 ), sendo seis colunas com perfil homogêneo e duas com perfil estratificado, sob condições de precipitação constante. Determinaram as características físico-hídricas dos solos das colunas necessárias à aplicação do modelo de GAML e, por meio da técnica chamada de “Time Domain Reflectometry” (TDR), foi possível determinar o avanço da frente de umedecimento a partir da qual foram determinadas a infiltração acumulada (Ia) e a taxa de infiltração (Ti). Os valores da umidade na zona de transmissão (θ w ), determinada ao final dos testes de infiltração, variaram de 0,76 a 0,94 da porosidade, dependendo da textura e da massa específica em questão. Esses valores foram usados como um dos parâmetros de entrada no modelo GAML. Curvas de avanço da frente de umedecimento, de infiltração acumulada e de taxa de infiltração foram simuladas usando o modelo GAML com 36 combinações de proposições para correção de Kw e ψ f . Os resultados simulados e experimentais foram comparados, usando-se coeficientes estatísticos e análise gráfica. Também foram comparados os tempos correspondentes ao início do escoamento superficial determinados experimentalmente e simulados. Não foi encontrada uma única combinação de proposições que melhor representasse todos os casos. No entanto, o uso da condutividade hidráulica (K w ) sendo igual a taxa de infiltração básica (Tib) e o do potencial matricial (ψ f ) calculado em função da textura e da porosidade do solo, fez com que o modelo GAML simulasse bem o processo de infiltração em solos com perfil de massa específica homogênea. Outra combinação que merece destaque é o uso de K w igual à condutividade hidráulica do solo saturado (K 0 ), determinada pelo método do permeâmetro de carga constante, associado ao potencial matricial (ψ f ) correspondente à umidade na zona de transmissão, que representou muito bem as curvas de infiltração obtidas nas colunas com perfil homogêneo dos horizontes A e B, para as duas condições de compactação. De modo geral, quando os parâmetros de entrada do modelo de GAML são bem determinados, o mesmo pode ser usado para a estimativa do processo de infiltração, em solos homogêneos. Em solos heterogêneos, o modelo foi sensível às variações físico-hídricas do perfil do solo, mas não foi preciso em estimar o tempo de ocorrência das mudanças na taxa de infiltração devido à estratificação do solo. / The infiltration models based on physical principles are important tools to be used on the hydrological modeling. The Green-Ampt model is one of these tools that has been being used in different areas related to the subject. However, the adequacy of its parameters to Brazilian soils still needs to be better studied. This work’s objective is to evaluate the different propositions of parameters determination (saturation humidity, q s ; hydraulic conductivity, K and matrix potential before humidification, y f ) of the Green-Ampt model modified by Mein and Larson (GAML) and its applicability to different conditions of homogeneous and heterogeneous soil profiles. The experiment was carried out in eight columns of soil mounted with different horizons combinations (A, B and C) and specific mass (1.03 g/cm 3 and 1.23 g/cm 3 ), being six of the columns with homogeneous profile and two of them with stratified profile, under constant precipitation conditions. The physical-hydric characteristics of the columns soils needed to the GAML model application were determined, and through the technique called “Time Domain Reflectometry” (TDR), it was possible to determine the advancement of the humidification front from which the accumulated infiltration (Ia) and the infiltration rate (Ti) were determined. The humidity value on the transmission zone (θ w ), determined at the end of the infiltration tests, varied from 0.76 to 0.94 of porosity, depending on the texture and on the specific mass in question. These values were used as one of the entrance parameters into the GAML model. Advancement curves of the humidification front, of the accumulated infiltration, and of the infiltration rate were simulated using the GAML model with 36 propositions combinations for the correction of Kw and ψ f . The simulated and experimental results were compared using statistic coefficients and graphic analyses. The times correspondent to the beginning of the superficial drainage experimentally determined and simulated were also compared. A sole combination of proposition that better represented all the cases was not found. However, the use of hydraulic conductivity (K w ) as being equals to the basic infiltration rate (Tib) and to the matrix potential (ψ f ) calculated in relation to the texture and porosity of the soil, made the GAML model simulate well the infiltration process on soils with profile of homogeneous specific mass. Another combination that deserves to be highlighted is the use of Kw equals to the hydraulic conductivity of the saturated soil (K 0 ), determined by the constant charge permeameter method, associated to the matrix potential (ψ f ) correspondent to the transmission zone humidity, that represented very well the infiltration curves obtained on the columns with homogeneous profile of the A and B horizons, for both compactness conditions. In general, when the entrance parameters of the GAML model are well determined, it can be used for the estimate of the infiltration process in homogenous soils. In heterogeneous soils the model was sensitive to the physical-hydric variations of the soil profile, but it was not necessary to estimate the occurrence time of changes on the infiltration rate due to the soil stratification. / Dissertação imortada do Alexandria
4

Cultivo e composição química de Ora-pro-nóbis (Pereskia aculeata Mill.) sob déficit hídrico intermitente no solo /

Queiroz, Carla Regina Amorim dos Anjos. January 2012 (has links)
Orientador: Luiz Carlos Pavani / Coorientador: Sérgio Antônio Lemos de Morais / Banca: Arthur Bernardes Cecílio Filho / Banca: Manoel Evaristo Ferreira / Banca: Deborah Santesso Bonnas / Banca: Othon Carlos da Cruz / Resumo: Plantas de Ora-pro-nóbis (OPN) foram submetidas, a partir de -5 kPa, à variação intermitente do potencial mátrico no substrato (PM) para até -10, -30, -50 ou -70 kPa (tratamentos). Com base no PM medido com tensiômetro de cápsula porosa e na curva de retenção de água do substrato foram aplicados os volumes de água por tratamento, em cada irrigação. Aos 140 dias após o transplantio a redução do PM provocou nas plantas estresse por déficit hídrico no solo em função da redução significativa do acúmulo de massa seca, mas o estresse foi de baixo a moderado uma vez que não ocorreu redução na área foliar e nem abscisão de folhas. Houve mudança na alocação de massa entre as partes, com maior redução em raízes, seguida de caules e folhas, além de redução na eficiência fotossintética, em função do decréscimo na área foliar específica e na razão de área foliar. Com menor PM a eficiência no uso da água foi maior, indicando bom potencial produtivo mesmo nessa condição; além de maior quantidade de células epidérmicas adaxiais, cujo tamanho foi reduzido. Os teores de macronutrientes em folhas seguiram a ordem Ca>N>K>Mg>P>S. Na planta toda, o teor de fósforo foi menor que os teores de N, K, Ca e Mg e maior que o S. Nas folhas de OPN a redução no PM de -10 kPa até -70 kPa, provocou redução no valor energético, extrato seco, fibra bruta e lipídeos, e aumento no teor de proteínas e carboidratos. Nos caules, resposta similar foi observada para o valor energético, extrato seco, proteínas e cinzas. Entretanto, para carboidratos e lipídeos, observou-se, respectivamente, redução e aumento dos teores em função da queda do PM. Os teores de lipídeos, cinzas e proteínas são maiores em folhas / Abstract: Ora-pro-nóbis plants (OPN) were submitted from -5 kPa to -10, -30, -50 or -70 kPa (treatments) of intermittent variation of the matric potential (PM) in the substrate. According to the measured PM with porous cup tensiometer and the water retention curve of substrate, were applied at each irrigation time the volume of water required for each treatment. Up to 140 days after transplanting the PM decrease caused stress on plants by soil water deficit as evidenced by significant reduction in dry mass accumulation, but the stress was low to moderate since there was no significant reduction in leaf area and nor abscission of leaves. There was change in allocation mass between its parts, greater reduction in roots followed by stems and leaves, and photosynthetic efficiency reduction, due to decrease in specific leaf area and leaf area ratio. Under lower PM, the water use efficiency was greater, indicating good productive potential even in this condition, besides a greater number of adaxial epidermal cells, whose size were reduced. In leaves, macronutrient contents followed the order Ca>N>K>Mg>P>S. In whole plant, the phosphorus content was lower than the levels of N, K, Ca and Mg and higher than S. In OPN leaves, PM decrease from -10 kPa to -70 kPa caused a reduction in the energy value, dry extract, crude fiber and lipids, and increased protein and carbohydrates. In stems, similar response was observed for energy value, dry matter, protein and ash. However, for carbohydrates and lipids was observed, respectively, decreased and increased levels due to PM decrease. The stem/leaf reasons revealed that lipids, ash and protein levels are higher in leaves / Doutor
5

Avaliação funcional de instrumentos de medição do potencial matricial da água do solo seco / Functional evaluation of instruments for measuring the water status of dry soil

Thaís Tokashiki Tavares Rodrigues 31 July 2017 (has links)
Estudos sobre a dinâmica da água no solo não-saturado passam pela medição, estimativa e/ou previsão do potencial matricial ou do teor de água. Diante disso, o objetivo da presente proposta foi realizar testes e avaliações de três instrumentos com características distintas, capazes de medir o potencial matricial da água no solo seco, sendo eles: um medidor baseado no ponto de orvalho (WP4), um instrumento baseado na pressão (tensiômetro de polímero-PoT) e um instrumento baseado na capacitância elétrica (FDR EC-5). A análise foi realizada em três partes: 1. Avaliação do WP4 com amostras com potencial equilibrado na câmara de Richards ou secas ao ar; 2. Avaliação dos PoT e 3. Experimento comparativo entre instrumentos em colunas de solo. Nesses experimentos foram utilizados materiais de solos com texturas diferentes (um de textura argilosa, um de textura média e um de textura arenosa). Os experimentos foram conduzidos no Laboratório de Física de Solo do CENA/USP em Piracicaba-SP. Os resultados mostram que o FDR EC-5 apresentou bons resultados em relação ao método que foi definido como padrão (método gravimétrico), por mais que possua erros associados à curva de retenção. O WP4, que possui uma ampla faixa de leitura de 0 a -30000 m, não se apresentou muito preciso para solos úmidos (h > -70 m) devido ao seu procedimento de leitura. Para solos muito secos, no entanto, ele se apresenta como uma boa opção. O tensiômetro de polímero mede a pressão diretamente na faixa entre 0 a -150 m. Esse instrumento requer cuidados com o coeficiente de calibração, a verificação do limite individual de funcionamento e o contato entre a cápsula porosa do tensiômetro e o solo / Studies about unsaturated soil water dynamics involve the measurement or prediction of matric potential and/or soil water content. In this study, the objective was to test and evaluate three measurement devices able to measure matric potential in dry soil: a dew point based instrument (WP4), a pressure based instrument (polymer tensiometer - PoT) and an electromagnetic capacitance based instrument (FDR EC-5). The analysis was performed in three steps: 1. Evaluation of WP4 using soil samples in equilibrium with a pressure chamber or with surrounding air; 2. Evaluation of PoT and 3. Experiments to compare devices in soil columns. In these experiments three soil textures were used (clay texture, silt texture and sand texture). The experiments were conducted in the soil physics lab at CENA/Universidade de São Paulo, Piracicaba, Brazil. Results show that the FDR EC-5 performed well when compared to the (standard) gravimetric method, even though it includes errors associated with the retention curve. The WP4 device has a wide reading range of 0 to -30000 m, but is not accurate for saturated or moist soils (h > -70 m) due to its working principle. For very dry soils, however, it is a good option. The polymer tensiometers measure pressure directly and perform in a range between 0 to -150 m. This equipment showed to require special care regarding its calibration coefficient, verification of individual reading limit and the porous cap-soil contact
6

Estudo da curva de retenção e condutividade hidráulica estimadas pela equação de van Genuchten (1980) para diferentes tipos de solo

Gonçalves, Fernanda Vescovi 25 October 2012 (has links)
Made available in DSpace on 2016-12-23T14:05:56Z (GMT). No. of bitstreams: 1 Fernanda Vescovi Goncalves 1.pdf: 4104793 bytes, checksum: 7c22c0d324845c2dc40c6e98de51cd73 (MD5) Previous issue date: 2012-10-25 / The van Genuchten (1980) equation has been widely used in the literature to represent analytically the soil water retention curve, and there are several published database tables which allow estimate the van Genuchten (1980) parameters (VG parameters) for different soils and regions. The equation enables one to derive closed-form analytical expressions for the unsaturated hydraulic conductivity function using Burdine (1953) and Mualem (1976) models. The objective of this dissertation is to study published database tables of the retention and hydraulic conductivity functions for different soils (Wosten et al.; 1999; Schaap et al., 2001; Hodnett and Tomasella, 2002; and Gerscovich and Sayão, 2002), and quantify the variation of VG parameters with the grain size distribution of these soils. The different experimental methods, the large variability of soils, and the lack of complete information of the soil properties of the investigated data, and the lack of physical meaning of VGparameters did not allow to define functions to quantify the variation of VGparameters with the grain size distribution for the investigated soils. The results suggest that there is no dependency between the VG parameters and the fine content of the investigated silty sand soils when the percentage of fines is such that it fills all large grains voids. In this case, the limited classification based only on soil texture can not be used to estimate the VG parameters. The variation of saturated hydraulic conductivity with fines content provides a useful means of assessing the existence of the dependency between the VG parameters and the soil texture. For the silty sandy soils evaluated in this study, when the fines content is higher that 30% there is no dependency between the VG parameters and the fines content. It is also observed that the soils that do not exhibit a significant difference in their saturated hydraulic conductivity values may exhibit large variations in their unsaturated hydraulic conductivity values depending on their fines content. For high suction values, the relative permeability of the soil specimens with 10% of fines content can be up to 1016 times lower than that of the soil specimens with 90% of fines content / Uma das equações mais utilizadas na literatura para representar analiticamente a curva de retenção de água no solo foi proposta por van Genuchten (1980) e, existem vários bancos de dados publicados com valores dos quatro parâmetros independentes de ajuste da equação para diferentes tipos de solos e regiões. A equação de van Genuchten (1980) possibilita a determinação de uma expressão analítica para a função de condutividade hidráulica de solos não saturados a partir dos modelos propostos por Burdine (1953) ou Mualem (1976). O objetivo deste trabalho é estudar curvas de retenção e condutividades hidráulicas publicadas na literatura para diferentes tipos de solos (Wosten et al.; 1999; Schaap et al., 2001; Hodnett e Tomasella, 2002; e Gerscovich e Sayão, 2002) e quantificar a variação dos parâmetros de van Genuchten (1980) com a distribuição granulométrica desses solos. Os diferentes métodos experimentais utilizados para determinar esses dados, a grande variabilidade de solos e regiões diferentes dos dados, a falta de informação completa das propriedades geotécnicas dos solos e a falta de significado físico dos parâmetros de van Genuchten (1980) não possibilitaram definir uma função que quantifique a variação dos parâmetros de de van Genuchten (1980) com a distribuição granulométrica para os solos analisados neste trabalho. As análises realizadas sugerem que não existe dependência entre o teor de finos/textura de solos granulares com finos e os parâmetros da equação de van Genuchten (1980) quando o percentual de finos é tal que preenche todos os vazios das partículas mais grossas. Neste caso a classificação exclusivamente por textura não pode ser usada para estimar os parâmetros de van Genuchen (1980). A variação da permeabilidade saturada com o teor de finos pode ser uma forma de indicar o valor do percentual de finos que isto acontece. Para os solos arenosos siltosos analisados este percentual de finos é aproximadamente 30%. Verifica-se que os solos que não apresentam uma diferença significativa na permeabilidade (condutividade hidráulica saturada) podem apresentar grandes variações nos valores da condutividade hidráulica não saturada dependendo do teor de finos desses solos, tal que para altos valores de sucções a permeabilidade relativa das amostras com até 10% de finos pode ser até 1016 vezes menor que a das amostras com percentual de finos superior a 90%
7

Manejo da irrigação na cultura do crisântemo (Dendranthema grandiflorum Ramat Kitamura) de corte cultivado em ambiente protegido /

Farias, Maryzélia Furtado de, 1973- January 2006 (has links)
Orientador: João Carlos Cury Saad / Banca: Roberto Lyra Villas Boas / Banca: Tarlei Arriel Botrel / Banca: Sergio Nascimento Duarte / Banca: Denise Laschi / Resumo: A irrigação é prática fundamental para o cultivo de crisântemo, porém seu manejo adequado tem sido negligenciado pelos produtores, resultando em prejuízos no crescimento vegetal e conseqüentes decréscimos na produtividade e na qualidade do produto final. A resposta das plantas à tensão de água no solo tem sido estudada como forma de controle da irrigação, já que irrigações deficitárias refletem diretamente na redução da produtividade, enquanto irrigações excessivas prejudicam a qualidade das flores. Buscando melhor representatividade dos dados obtidos, desenvolveu-se esta pesquisa na propriedade Steltenpool, no Distrito de Holambra II, município de Paranapanema-SP, em cultivos rotineiramente desenvolvidos pelo produtor. O objetivo principal deste experimento foi identificar a tensão de água no solo que pudesse resultar na melhor qualidade comercial do crisântemo de corte, cultivar Dark Orange Reagan. O delineamento experimental adotado foi inteiramente casualizado com 3 repetições, dividido em 30 parcelas, cada uma controlada por registro, com 4 fitas gotejadoras. Os tratamentos foram definidos por dez níveis de tensão de água no solo: 5, 10, 15, 20, 25, 30, 35, 40, 45 e 50 kPa. Foram realizadas avaliações da área foliar, matéria seca, diâmetro e altura das plantas, em intervalos de 14 dias, utilizando-se 3 plantas por parcela, escolhidas ao acaso, a partir dos quais se realizou análise de crescimento. Os resultados demonstram não haver diferença significativa entre os tratamentos para a maioria dos parâmetros avaliados. Os tratamentos irrigados com as tensões 20 e 50 kPa resultaram na maior produção de matéria seca e no maior número de pacotes A1, ou seja, com 2 o melhor padrão de qualidade. A maior durabilidade pós-colheita foi obtida com o emprego da giberelina (GA3) nas tensões de 30 e 50 kPa. / Abstract: Irrigation is an important practice for chrysantemum growing, but most of growers didnþt adopt any kind of water scheduling and it results in yield reduction and quality lost of the final product. Soil water tension has been used with success as a criterion of irrigation scheduling. It avoids the excessive application that frequently results in lost of quality. Looking for the best representation of the obtained data, this research was developed in the denominated property Steltenpool, in the municipal district of Holambra II, area of Paranapanema-SP, in cultivations developed by the producer. The aim of this research was identify the soil water tension that results in the best quality of the cut chrysanthemum, Dark Orange Reagan cultivar. Experimental design was totally randomized with 3 repetitions, subdivided in 30 parcels, each one controlled by a register, with drip tape lines. Treatments were defined for 10 soil water tension levels: 5, 10, 15, 20, 25, 30, 35, 40, 45 e 50 kPa. Evaluations of leaves area, dried weight, diameter and plants high were done each 14 days period, using 3 plants per parcel that were used in growing analysis. Results showed that there is no difference among treatments for most of the evaluated variables. Plants irrigated with soil water tensions of 20 and 50 kPa showed the biggest dried weight and in highest number of A1 pack that means the highest quality. The longest durability was obtained with gibberellin (GA3) associated with soil water tensions of 30 and 50 kPa. / Doutor
8

Aplicação da equação de Green-Ampt na modelagem da infiltração de água em Latossolo Vermelho-Amarelo estratificado / Application of the Green-Ampt equation in the simulation of water infiltration into stratified Red-Yellow Latosol

Cecílio, Roberto Avelino 15 March 2002 (has links)
Submitted by Marco Antônio de Ramos Chagas (mchagas@ufv.br) on 2017-02-07T17:58:29Z No. of bitstreams: 1 texto completo.pdf: 1923087 bytes, checksum: e5b814c431e57c85ed8aea99289998c6 (MD5) / Made available in DSpace on 2017-02-07T17:58:29Z (GMT). No. of bitstreams: 1 texto completo.pdf: 1923087 bytes, checksum: e5b814c431e57c85ed8aea99289998c6 (MD5) Previous issue date: 2002-03-15 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / A infiltração de água no solo é um dos principais fenômenos componentes do ciclo hidrológico, pois é um dos fatores que determinam a disponibilização de água para as culturas, a recarga dos aqüíferos subterrâneos, a ocorrência e magnitude do escoamento superficial e o manejo do solo e da água. O modelo de Green-Ampt é um dos mais utilizados na previsão da infiltração por se basear em aspectos físicos do processo, entretanto diversos autores alertam para a necessidade de adequação dos parâmetros de entrada deste modelo para as condições de campo. Como este modelo foi desenvolvido para solos homogêneos faz-se necessário a realização de estudos deste em solos estratificados, principalmente para solos típicos de regiões de clima tropical. Neste trabalho, procurou-se avaliar o modelo de Green-Ampt, assim como as diversas proposições de correção dos seus parâmetros de entrada (umidade de saturação, θ s ; condutividade hidráulica do solo saturado, K 0 ; e, potencial matricial na frente de umedecimento, ψ), aplicado a um típico solo brasileiro sob condições de estratificação de sua textura, o Latossolo Vermelho-Amarelo. Foram conduzidos dois experimentos, um utilizando colunas e outro uma caixa de solo, dentro dos quais compactou-se material de solo pertencente a cada um dos três horizontes do Latossolo Vermelho- Amarelo (A, B e C). Determinou-se a infiltração acumulada (I), taxa de infiltração (Ti), bem como as características físicas do perfil necessárias para a aplicação do modelo de Green-Ampt. Verificou-se que o valor de umidade de saturação de campo (θ w ) que melhor simulou os valores medidos de infiltração quando não se considera θ w variável com a textura do solo variou entre 0,81 θ s (caixa de solo) e 0,86 θ s (colunas de solos). Quando se considera, para a caixa de solo, θ w variável com a textura, os melhores valores foram de 0,79 θ s para o material de solo de textura argilosa (horizontes A e B) e 0,86 θ s para o material de solo de textura franca (horizonte C). Utilizando-se estes valores nas simulações de Ti, I e profundidade da frente de umedecimento, percebeu-se que a textura do solo exerce grande influência no valor de θ w , pois todas as simulações foram melhores quando se considerou a variação deste parâmetro de acordo com a granulometria do material de solo. Utilizando-se, nas simulações, combinações entre seis metodologias para o cálculo de ψ e três para a determinação da condutividade hidráulica, percebeu-se que três diferentes combinações simularam bem a infiltração ocorrida nas colunas (condição de baixa umidade inicial) e que quatro diferentes combinações simularam bem o processo de infiltração ocorrido na caixa de solo (condição de alta umidade inicial). Para a condição de baixa umidade inicial (colunas de solo), as proposições que melhor simularam a infiltração foram: K w igual a 0,5 K 0 associada a ψ igual a ψ (θ i ); K w igual a K 0 associada a ψ igual à média entre ψ (θ w ) e ψ (θ i ) e; K w igual à taxa de infiltração estável (T ie ) associada a ψ calculado com base na textura e porosidade do solo. Já para a condição de alta umidade inicial (caixa de solo), estas proposições foram: condutividade hidráulica (K w ) igual a 0,5 K 0 associada ao potencial matricial na frente de umedecimento (ψ) igual a ψ (θ i ); K w igual à T ie associada a ψ igual à média entre ψ (θ w ) e ψ (θ i ); K w igual a K 0 associada a ψ calculado com base na textura e porosidade do solo e; K w igual à T ie associada a ψ calculado com base na textura e porosidade do solo. Duas das combinações foram exatamente as mesmas tanto para a condição de alta, quanto de baixa umidade inicial. O modelo de Green-Ampt simulou melhor o processo de infiltração da água no Latossolo Vermelho- Amarelo estratificado quando este apresentou menor variação na condutividade hidráulica ao longo do perfil. / Soil water infiltration is one of the most important components of the hydrological cycle because it is one of the factors that determines the water that will be avaible for the cultures, the recharge of the underground aquifers, the occurrence and magnitude of the surface runoff and the handling of soil and water. The Green-Ampt model is one of the most used in the prediction of infiltration because it’s based in the physical aspects of the process, however several authors alerts for the need of some adaptation in the model’s input parameters for field conditions. As the Green and Ampt model was developed for homogeneous soils it’s necessary the accomplishment of studies in stratified soils, mainly for typical soils of tropical climate areas. In this work, it was tried to evaluate the Green-Ampt model, as well as several propositions of correction of its entrance parameters (saturation moisture, θ s ; saturated hydraulic conductivity, K 0 ; and, matric potential in the wetting front, ψ), applied to a typical Brazilian soil under stratified conditions, the Red-Yellow Latosol. Two experiments were led, one using soil columns and other using a soil box, were soil material belonging to each one of the three horizons (A, B and C) of the studied soil was compacted. The accumulated infiltration (I) was determined, as well as the infiltration rate (Ti) and the physical characteristics of the profile that were needed for the application of the Green-Ampt model. It was verified that the value of field saturation moisture (θ w ) that best fitted experimental data when it’s not considered θ w variable with the texture of the soil varied among 0,81 θ s (soil box) and 0,86 θ s (soil columns). For the soil box, when was considered that θ w was variable with the texture, the best values were 0,79 θ s for the material of soil of clay texture (horizons A and B) and 0,86 θ s for the material of soil of sandy loam texture (horizon C). Using these values in the Ti, I and wetting front depth simulations, it was noticed that the soil texture exercises great influence in the value of θ w , because all the simulations were better when it was considered the variation of this parameter in agreement with the soil material texture. Using, in the simulations, combinations among six methodologies for the ψ calculation and three for the hydraulic conductivity determination, it was noticed that three different combinations simulated well the infiltration that happened in the columns (condition of low initial moisture) and that four different combinations simulated well the infiltration process that happened in the soil box (condition of high initial moisture). For the condition of low initial moisture (soil columns), the propositions that best simulated the infiltration process were: hydraulic conductivity (K w ) equals to 0,5 K 0 associated with ψ equals to ψ (θ i ); K w equals to K 0 associated to ψ equals to the average among ψ (θ w ) and ψ (θ i ) and; K w equals to the stable infiltration rate (T ie ) associated to ψ calculated with base in soil texture and soil porosity. For the high initial moisture condition (soil box), these propositions were: hydraulic conductivity (K w ) equals to 0,5 K 0 associated with ψ equals to ψ (θ i ); K w equals to T ie associated to ψ equal to the average among ψ (θ w ) and ψ (θ i ); K w equals to K 0 associated to ψ calculated with base in soil texture and soil porosity and; K w equals to T ie associated to ψ equal to calculated with base in soil texture and soil porosity. Two of the combinations were exactly the same for both of the experiments. The Green-Ampt model simulated better the water infiltration process when the soil profile presented lower variation in the hydraulic conductivity. / Dissertação importada do Alexandria
9

Manejo da irrigação na cultura do crisântemo (Dendranthema grandiflorum Ramat Kitamura) de corte cultivado em ambiente protegido

Farias, Maryzélia Furtado de [UNESP] 06 February 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:43Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-02-06Bitstream added on 2014-06-13T20:43:46Z : No. of bitstreams: 1 farias_mf_dr_botfca.pdf: 610419 bytes, checksum: 276016d016772019969a7ff54d9cfcd3 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Universidade Estadual Paulista (UNESP) / A irrigação é prática fundamental para o cultivo de crisântemo, porém seu manejo adequado tem sido negligenciado pelos produtores, resultando em prejuízos no crescimento vegetal e conseqüentes decréscimos na produtividade e na qualidade do produto final. A resposta das plantas à tensão de água no solo tem sido estudada como forma de controle da irrigação, já que irrigações deficitárias refletem diretamente na redução da produtividade, enquanto irrigações excessivas prejudicam a qualidade das flores. Buscando melhor representatividade dos dados obtidos, desenvolveu-se esta pesquisa na propriedade Steltenpool, no Distrito de Holambra II, município de Paranapanema-SP, em cultivos rotineiramente desenvolvidos pelo produtor. O objetivo principal deste experimento foi identificar a tensão de água no solo que pudesse resultar na melhor qualidade comercial do crisântemo de corte, cultivar Dark Orange Reagan. O delineamento experimental adotado foi inteiramente casualizado com 3 repetições, dividido em 30 parcelas, cada uma controlada por registro, com 4 fitas gotejadoras. Os tratamentos foram definidos por dez níveis de tensão de água no solo: 5, 10, 15, 20, 25, 30, 35, 40, 45 e 50 kPa. Foram realizadas avaliações da área foliar, matéria seca, diâmetro e altura das plantas, em intervalos de 14 dias, utilizando-se 3 plantas por parcela, escolhidas ao acaso, a partir dos quais se realizou análise de crescimento. Os resultados demonstram não haver diferença significativa entre os tratamentos para a maioria dos parâmetros avaliados. Os tratamentos irrigados com as tensões 20 e 50 kPa resultaram na maior produção de matéria seca e no maior número de pacotes A1, ou seja, com 2 o melhor padrão de qualidade. A maior durabilidade pós-colheita foi obtida com o emprego da giberelina (GA3) nas tensões de 30 e 50 kPa. / Irrigation is an important practice for chrysantemum growing, but most of growers didnþt adopt any kind of water scheduling and it results in yield reduction and quality lost of the final product. Soil water tension has been used with success as a criterion of irrigation scheduling. It avoids the excessive application that frequently results in lost of quality. Looking for the best representation of the obtained data, this research was developed in the denominated property Steltenpool, in the municipal district of Holambra II, area of Paranapanema-SP, in cultivations developed by the producer. The aim of this research was identify the soil water tension that results in the best quality of the cut chrysanthemum, Dark Orange Reagan cultivar. Experimental design was totally randomized with 3 repetitions, subdivided in 30 parcels, each one controlled by a register, with drip tape lines. Treatments were defined for 10 soil water tension levels: 5, 10, 15, 20, 25, 30, 35, 40, 45 e 50 kPa. Evaluations of leaves area, dried weight, diameter and plants high were done each 14 days period, using 3 plants per parcel that were used in growing analysis. Results showed that there is no difference among treatments for most of the evaluated variables. Plants irrigated with soil water tensions of 20 and 50 kPa showed the biggest dried weight and in highest number of A1 pack that means the highest quality. The longest durability was obtained with gibberellin (GA3) associated with soil water tensions of 30 and 50 kPa.
10

Avaliação experimental de um modelo numerico para o processo de redistribuição da agua no solo

Poliseli, Paulo Cesar 21 August 2012 (has links)
Resumo: Para simular o processo transiente da redistnouição da água no solo, para a direção vertical, PREVEDELLO (1996) desenvolveu um modelo numérico em linguagem BASIC de programação (Beginner's All-purpose Symbolic Instructional Code). O desenvolvimento do modelo baseou-se na linearização da equação de RlCHARDS (1931), à qual governa o movimento da água no solo, através da utilização de uma simplificação da relação entre a condutividade hidráulica e a tensão da água (K ('I'm )), sugerida por van GENUCHTEN (1980), e aliando a utilização da técnica iterativa de Newton-Raphson para solução de equações não-lineares. Para testar o desempenho do modelo em predizer a variação em umidade "() ) e tensão da água ('I'm ) no tempo e no espaço, foram escolhidos dados da literatura de dois materiais porosos com diferentes propriedades hidráulicas. Dessa forma, foram escolhidos uma areia marinha estudada por CHO et alo (1977) e um latossolo vermelho amarelo textura média, estudado por LIBARDI (1978). Os resultados encontrados permitiram as seguintes conclusões: (i) em ambos os materiais porosos estudados o desempenho do modelo foi altamente satisfatório, onde os perfis de umidade e de tensão da água transladaram-se satisfatóriamente no tempo; (ii) o modelo também foi capaz de prever muito bem o comportamento da densidade de fluxo em função do tempo; (iü) os maiores desvios do modelo em relação aos de campo foram encontrados nos tempos iniciais. do processo de redistribuição da água, devido à limitação da teoria pela simplificação realizada na equação de van GENUCHTEN (1980) por PREVEDELLO (1996), muito embora esses desvios representem apenas 0,2 % do tempo total estudado no experimento em duna de areia, e 2,5 % para o latossolo; (iv) o desempenho do modelo foi ligeiramente superior para a areia marinha em relação ao latossolo, devido, provavelmente, à maior homogeneidade nas propriedades hidráulicas da areia.

Page generated in 0.3207 seconds