Spelling suggestions: "subject:"prótese dentária"" "subject:"próteses dentária""
1 |
Protese com encaixe de semi-precisãoMeneghel, Ataualpa Francisco Pacheco 03 August 2018 (has links)
Orientador: Krunislave Antonio Nobilo / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-03T10:26:37Z (GMT). No. of bitstreams: 1
Meneghel_AtaualpaFranciscoPacheco_D.pdf: 1909368 bytes, checksum: ef9926c97acbeb1e5cb8439d56adf20d (MD5)
Previous issue date: 1971 / Resumo: Não informado / Abstract: Not informed / Doutorado / Protese Dental / Doutor em Ciências
|
2 |
Comparação entre dois metodos para o registro dos contatos oclusaisCabral, Claudio Wilson Lima Ferro 03 August 2018 (has links)
Orientador : Frederico Andrade e Silva / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-03T14:40:21Z (GMT). No. of bitstreams: 1
Cabral_ClaudioWilsonLimaFerro_M.pdf: 3085734 bytes, checksum: ad46f1bae9a606eea7f81afa3cdd1248 (MD5)
Previous issue date: 2003 / Mestrado
|
3 |
Reprodução dos dentes remanescentes nas proteses imediatas : (uma tecnica para contribuição ao seu estudo)Mazzonetto, Sergio Francisco, 1936- 20 July 2018 (has links)
Orientador: Krunislave Antonio Nobilo / Tese (doutorado) - Universidade de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-20T13:35:34Z (GMT). No. of bitstreams: 1
Mazzonetto_SergioFrancisco_D.pdf: 1140028 bytes, checksum: a9fde08ed472d8db9b6aead3f38b900d (MD5)
Previous issue date: 1967 / Resumo: Não informado / Abstract: Not informed. / Doutorado / Protese Dental / Doutor em Ciências
|
4 |
Dentaduras completas : alterações dimensionais de algumas medidas horizontais e verticaisPacheco, Fernando Antonio de Azevedo, 1936- 20 July 2018 (has links)
Orientador: Krunislave Antonio Nobilo / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-20T17:11:37Z (GMT). No. of bitstreams: 1
Pacheco_FernandoAntoniodeAzevedo_D.pdf: 1244971 bytes, checksum: 3cb6ab8c68ceb8d092f75b76ed0d4078 (MD5)
Previous issue date: 1968 / Resumo: Não informado / Abstract: Not informed. / Doutorado / Protese Dental / Doutor em Clínica Odontológica
|
5 |
Estomatite protética em pacientes com Diabetes mellitus: prevalência de Candida spp. e eficiência dos tratamentos com nistatina e desinfecção de próteses por micro-ondasSanitá, Paula Volpato [UNESP] 26 May 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:02Z (GMT). No. of bitstreams: 0
Previous issue date: 2011-05-26Bitstream added on 2014-06-13T19:44:49Z : No. of bitstreams: 1
sanita_pv_dr_arafo.pdf: 1953204 bytes, checksum: a2f3ce08a1a45c4435513d02ab367cba (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Este estudo in vivo teve como objetivos avaliar: 1. a prevalência das diferentes espécies de Candida em pacientes diabéticos portadores de estomatite protética e compará-la àquela de pacientes não diabéticos com/sem estomatite protética; 2. a eficiência de dois tratamentos para estomatite protética em pacientes diabéticos: terapia antifúngica com nistatina e desinfecção de próteses totais por micro-ondas. Para isso, 210 pacientes usuários de prótese totais foram selecionados e distribuídos em três grupos de estudo. O grupo controle - GC foi formado por 90 pacientes não diabéticos e com mucosa oral saudável; os grupos experimentais foram formados por portadores de estomatite protética, sendo 80 pacientes não diabéticos - EPND e 40 diabéticos do tipo 2 controlados - EPD. Uma avaliação intra-oral dos pacientes dos grupos experimentais foi realizada e a aparência clínica da mucosa inflamada foi classificada de acordo com os critérios de Newton em graus I, II ou III. Coletas microbiológicas das próteses totais foram realizadas com swab estéril e plaqueadas em meio CHROMagar Candida. Em seguida, os procedimentos de identificação foram realizados: análise de microcultivo, teste de triagem fenotípica em caldo hipertônico e testes bioquímicos (ID-32C). Os resultados obtidos foram analisados por Intervalo de Confiança de Bonferroni e testes Exato de Fisher e Qui Quadrado (α=0,05). Os 40 pacientes diabéticos foram, então, submetidos ao tratamento da estomatite protética. Para isso, foram aleatoriamente distribuídos em 2 grupos (n=20): grupo NIS – tratamento com antifúngico tópico nistatina (suspensão oral - 100.000UI/mL), 4 vezes ao dia, por 14 dias; grupo MIC – tratamento por meio da irradiação das totais por micro-ondas (650W / 3 minutos), 3 vezes por semana, por 14 dias. Dois parâmetros... / The aim of this in vivo study was to evaluate: 1. the prevalence of Candida spp. in well-controlled type 2 diabetic patients and compare it to that found in non-diabetics with/without denture stomatitis; 2. the efficacy of two treatments of denture stomatitis in diabetic patients: topical nystatin and denture microwave disinfection. Two hundred and ten denture wearer patients were divided into three groups of study. The control group - CG was formed by 90 individuals without diabetes or denture stomatitis and the experimental groups were formed by patients with denture stomatitis, being 80 non-diabetics - DSND and 40 well-controlled type 2 diabetics - DSD. Mucosal characteristics of denture stomatitis patients were classified in types I, II, and III, according to Newton’s criteria. Mycological samples were taken from the dentures and cultured in CHROMagar′s plates. Candida spp. were identified by micro-cultivation, hypertonic Sabouraud broth, and bioMérieux ID32C assays. Results were analyzed by means of Bonferroni corrected confidence interval, Fisher’s exact test, and Chi-square analysis of several proportions (α=0.05). The 40 diabetic patients were divided into two groups (n=20) and submitted to two treatments for denture stomatitis: NYS group – patients were treated with topical nystatin, 4 times a day, for 14 days; MW group – patients had their dentures microwaved (650W / 3 minutes), 3 times per week, for 14 days. Mycological samples were taken from the palates and the tissue surface of the dentures for quantification and identification of Candida spp. and standardized photographs of the palates were taken for the clinical analysis. Microbiological and clinical evaluations were repeated at baseline... (Complete abstract click electronic access below)
|
6 |
Programação de articuladores em protese total : comparação entre metodosCardoso, Luiz Antonio Morais, 1963- 08 January 1998 (has links)
Orientador: Jose Roberto Lovadino / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-23T03:09:08Z (GMT). No. of bitstreams: 1
Cardoso_LuizAntonioMorais_D.pdf: 1865461 bytes, checksum: eae73caa17a06a50397f7619a4458242 (MD5)
Previous issue date: 1997 / Resumo: Neste estudo foram considerados dois valores de grande interesse protético: inclinação da trajetória condílica ântero-posterior (guia condilar) e ângulo de Bennett. Essas duas grandezas serviram para referência de comparação entre dois métodos de programação de articuladores empregados na confecção de próteses totais. O primeiro método foi o chamado desgaste de Paterson que utiliza arcos de orientação com mistura abrasiva, que atritados pelo próprio paciente, conforma individualmente cada conjunto, que por sua vez, serve para programar o articulador. O segundo método, chamado técnica de Nóbilo, emprega o registro intra oral modificado, permitindo que as posições de interesse para a programação do articulador sejam definidas e tranferidas com o auxílio de moldagens vestibulares das posturas. Os métodos foram aplicados em 27 pacientes desdentados totais. Para a inclinação da guia condilar, o método de Paterson obeve média de 26,10 graus e o de Nóbilo 30,87 graus. Para o ângulo de Bennnett, o método de Paterson conseguiu 13,14 graus e o de Nóbilo 16,34 graus. Para ambos os valores protéticos a análise de variância considerou haver diferença entre os resultados obtidos pelos métodos. No entanto, em relação ao lado das articulações, nenhum método detectou diferença / Abstract: In this study were considerate two values with big prosthetic interest: anterior-posterior trajectory inclination of condyle and Bennett angle. These two greatness were useful for reference to compare two methods of articulators programation employed in dentures construclion. The first method was called Paterson abrasion that wich utilize orientation arcs with abrasive misture, frictioned for the own patient conform individualy each conjunct; that which in this way serve to articulator shedule. The second method, called Nobilo's technique used the intra-oral register modifyed, allowing to be defined to the articulator sheduling to be able to be defined and transfered with the vestibular posture impression. The methods were apliyed in 27 patients. To the inclination of condylar guide, the Paterson method got 26.10 grades and Nobilo's one got 30.87 grades. To the Bennett angle, Paterson method got 13.14 grades and Nobilo's one got 16.34 grades. To both prosthetic values, the variance analysis considered to the difference between the results got for the two methods. Never the lless in articulations side relation, no one method detected differences / Doutorado / Protese / Doutor em Clínica Odontológica
|
7 |
Efeito de um limpador de protese na concentração de compostos sulfurados volateis e na microbiota bucal de pacientes idosos institucionalizados portadores de proteses totaisOliveira, Viviane Maia Barreto de 11 November 2003 (has links)
Orientadores: Altair A. Del Bel Cury, Pedro Luiz Rosalen / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-03T18:53:40Z (GMT). No. of bitstreams: 1
Oliveira_VivianeMaiaBarretode_D.pdf: 3110818 bytes, checksum: 40e9aa33bfe2bfa6fd45609e4b286025 (MD5)
Previous issue date: 2003 / Resumo: O objetivo deste estudo foi verificar a eficácia do limpador de prótese Polident 5 minutes@ (Block and Drug Corp.) quanto à redução da concentração de Compostos Sulfurados Voláteis (CSV), por meio do Halimeter@ (Interscan Corp.) e a ação bactericida pela cultura microbiana em ágar sangue e MacConkey, além de avaliar a correlação entre a habilidade em higienizar as próteses (HA) e o índice de biofilme (IB) sobre as mesmas. Foram selecionados 19 voluntários, com idades entre de 62 a 86 anos, portadores de pelo menos prótese total superior. As análises foram realizadas em duas fases (F). FI: avaliação m e verificação HA, determinação da concentração de CSV e coleta do biofilme das próteses antigas, nos tempos To (sem uso do limpador), TI, T2eT3 (uso contínuo do limpador por 7, 14 e 28 dias); FII: novas próteses foram instaladas, a concentração de CSV foi determinada e o biofilme foi coletado após 30, 60 e 90 dias de uso contínuo do limpador (Tu, T2.2, T3.3). Os resultados para a concentração de CSV apresentaram diferença estatística entre os períodos Toe TI, e Tu e T 2.2, verificada pelo 64, 67A; T3.3: 53,67B. Na avaliação de microrganismos crescidos em aerobiose os resultados não mostraram diferença estatística significativa na FI e na F 11 houve diferença estatística entre todos os tempos, verificada pelo Teste T pareado (p<0,05): To: 3,34a; TI: 2,22a; T2: 2,92a; T3: 4,24a; Tu: O, 14c; T2.2: 1,12B; T33: 2,74B. Concluiu-se que houve uma correlação positiva entre a HA e m, que o limpador não foi eficaz na remoção do biofilme aderido à prótese antiga e não impediu a formação de biofilme nas novas próteses, assim como não reduziu os níveis de CSV dos pacientes / Abstract: The purpose of this study was to determine the effectiveness of the Polident 5 minutes@ (Block and Drug Corp.) denture cleanser in reducing V olatile Sulphur Compounds (VSC) concentration, estimated by Halimeter@ (Interscan Corp.) and the bactericide action by Blood Ágar and MacConkey culture, besides evaluating the correlation among the denture cleaning dexterity (DC) and the biofilm index (BI). 19 volunteers were selected with age range 62 to 86 years, wearing at least the upper denture. The analysis was conducted in two phases (P): PI: BI evaluation, volunteers DC, determination of VSC concentration and the biofilm was collected ITom the old denture before the use of the treatment protocol (To), and after 7, 14 and 28 days of continuous cleanser use (TI, T2 and T3); Pu: new denture was installed, VSC concentration was determinated and biofilm was collected at 30, 60 and 90 days with daily use ofthe denture cleanser (Tu, T2.2, T3.3). The VSC concentration results showed statistical difference between To and results did not show statistical difference at Phase I and, at Phase 11, there was statistical difference between alI the times, by paired-T test (p<0.05): To: 3,343; TI: 2,223; T2: 2,923; denture cleanser was not efficient to remove the old denture biofilm, did not prevent the new denture biofilm and did not reduce patients VCS levels / Doutorado / Protese Dental / Doutor em Clínica Odontológica
|
8 |
Dimensão vertical de oclusão em desdentados totais obtida pelos métodos de Tamaki de Beresin & Schiesser: estudo comparativo.De Jesus Tavarez, Rudys Rodolfo 08 August 1997 (has links)
A dimensão vertical de oclusão obtida pelos métodos de Tamaki e de Beresin & Schiesser; e a altura das próteses que os pacientes utilizavam, foram determinadas em uma amostra de 30 pacientes desdentados totais superior e inferior, com idade entre 38 e 77 anos; apresentando prótesis totais duplas totais em uso por um período mínimo de cinco anos, rebordos alveolares clinicamente favoráveis, ausência de sintomas de desordens temporomandibulares, com movimentos mandibulares normais. Os valores obtidos em cada um dos métodos testados foram comparados e relacionados com as alturas encontradas nas próteses que os pacientes utilizavam. Os resultados obtidos permitiram concluir que: 1) houve diferença estatisticamente significante em nível de 0,01 %, quando se compararam os valores obtidos pelos dois métodos; 2) quando comparados os métodos de Tamaki e Beresin & Schiesser em relação as alturas das próteses utilizadas, pode-se observar uma diferença média positiva de 3,02mm e 4,40mm respectivamente. / The vertical dimension of oclussion obtained by Tamakis and Beresin & Schiessers methods and the height of the complete dentures used by the patiens were obtained in a 30 edentulous persons sample with ages ranging from 38 to 77 years old, that had been wearing superior and inferior complete dentures for at least 5 years, in hose residual ridges were clinically favorable, and showing normal mandibular movements and absence of temporomandibular disordens. The purpose of this study was comparing the values obteined in each of the tested methods and correlating them with the heights taken of the dentures usedby the patients. As so checking the correspondence grade existing in each one. The results showed that: 1) There was statistically significant difference when comparing the values obteined in the two methods; being that there was a great correlation between these values to the leve of 0,01 %; 2) When comparing Tamakis and Beresin & Schiessers methods in relation to the heights of dentures used, a positiver medium difference could be observed, of 3.02mm and 4.40mm respectively.
|
9 |
Análise qualitativa dos fatores funcionais e psicossociais relacionados ao uso de próteses totais fabricadas pelas técnicas covencional e CD4Dalberto, Charlene da Silveira January 2015 (has links)
A implantação dos Laboratórios Regionais de Prótese Dentária (LRPD), através do Programa Brasil Sorridente, foi um importante passo para a abordagem da necessidade crescente de reabilitação protética da população idosa brasileira. Apesar dos incentivos à expansão dos LRPDs, há uma grande parcela da população edêntula com demanda reprimida de próteses totais. Assim, a aplicação de uma técnica abreviada para a fabricação de próteses totais em quatro sessões clínicas (CD4) pode otimizar o processo de reabilitação oral nos serviços de saúde. O objetivo desse estudo foi explorar e compreender as percepções dos aspectos funcionais e psicossociais relacionados ao uso de próteses totais fabricadas pelas técnicas convencional e CD4, por meio de uma abordagem qualitativa. Para isso, foram selecionados 20 participantes entre os pacientes que procuraram atendimento para reabilitação com prótese total dupla na Faculdade de Odontologia da Universidade Federal do Rio Grande do Sul, Porto Alegre, RS, Brasil. Os participantes foram randomizados em dois grupos e reabilitados com próteses totais convencionais (C), de seis sessões clínicas, e CD4, de quatro sessões clínicas. Após 6 meses da instalação e uso das novas próteses, foram realizadas entrevistas individuais abertas baseadas em um roteiro semiestruturado. As entrevistas foram registradas em gravações de áudio no formato mp3 e os participantes foram identificados por códigos (P1 ao P20) para o cegamento dos avaliadores. Os áudios das entrevistas foram transcritos e importados para um software de análise qualitativa (NVivo). As transcrições foram analisadas com base nos procedimentos e critérios inspirados na Teoria Fundamentada em Dados, de acordo com Strauss e Corbin. O processo de análise iniciou pela definição de conceitos e formação de categorias, seguido do agrupamento em domínios, e determinação das interações e dimensões. Os resultados foram refinados para a identificação de uma categoria central que integrou as demais categorias. Dez categorias foram identificadas e agrupadas em dois domínios: Funcional (Mastigação, Desconforto e dor, Estabilidade e retenção das próteses, Fonética) e Psicossocial (Resiliência, Estratégias de enfrentamento (coping), Emoções, Autoimagem e Interação social). E, em um nível maior de abstração, a Satisfação com as próteses emergiu como fenômeno central do uso das próteses de ambas técnicas. De acordo com os resultados, os fatores psicológicos influenciaram a Satisfação com o uso de próteses totais, através da interação entre os domínios Funcional e Psicossocial mediada pela Resiliência e as Estratégias de enfrentamento. Essa interação pode ter impacto sobre a capacidade positiva de adaptação do paciente ao uso de novas próteses, independentemente da técnica de fabricação. As percepções sobre os aspectos funcionais e psicossociais dos pacientes reabilitados a partir da técnica CD4 foram similares às dos que usaram próteses convencionais após 6 meses de uso das próteses, sem desvantagens quanto à satisfação final com o tratamento reabilitador. Portanto, as próteses totais convencionais e CD4 não apresentaram diferenças funcionais e psicossociais sob a percepção dos participantes.
|
10 |
Avaliação de fendas interfaciais de facetas cerâmicas minimamente invasivasSiedschlag, Gustavo January 2016 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2016 / Made available in DSpace on 2016-09-20T04:43:14Z (GMT). No. of bitstreams: 1
340519.pdf: 20067846 bytes, checksum: 217bd22919cc06cb7bc6895571a11ab0 (MD5)
Previous issue date: 2016 / O objetivo deste estudo foi avaliar a influência do desenho do preparo de restaurações cerâmicas do tipo faceta na integridade marginal imediata e após 5 anos de envelhecimento simulado, em diferentes regiões do dente. Material e métodos. Foram selecionados 30 dentes pré-molares superiores humanos hígidos e divididos aleatoriamente em 3 grupos (n=10), de acordo com o desenho do preparo da restauração cerâmica: G1: faceta total com preparo (Convencional); G2: faceta total sem preparo (Lente de Contato); G3: faceta parcial sem preparo (Fragmento). Os preparos do G1 foram controlados por meio de guias de silicone (vertical e horizontal, 0,5 mm redução axial vestibular). Os dentes foram incluídos em resina de poliestireno com simulação do ligamento periodontal. Trinta restaurações cerâmicas de dissilicato de lítio foram produzidas utilizando tecnologia CAD/CAM com espessura padronizada 0,5 mm e espaço interno 100 µm. As restaurações cerâmicas foram cimentadas adesivamente e envelhecidas com ciclagem termo-mecânica (CTM) (1.200,000 ciclos mastigatórios; 50 N; 2 Hz; e 6.000 ciclos térmicos 5o / 55o C, 2 min cada ciclo) para simular 5 anos de serviço clínico. Os espécimes foram escaneados por microtomografia computadorizada por raios-X (Micro-CT) para análise 3D da adaptação marginal (µm) em três regiões (cervical, proximal, oclusal) antes e após a CTM. Os dados foram analisados estatisticamente pelo ANOVA de 2 fatores, seguido pelo teste de Tukey (?? = 5%). Resultados. Os resultados de adaptação marginal (µm) e desvio padrão antes a CTM para as regiões cervical, oclusal e proximal, respectivamente foram: G1 (51,5 ± 9,4; 51,5 ± 21,8; 59,7 ± 12,9), G2 (45,3 ± 9,7; 65,1 ± 11,8; 52,0 ± 7,0), G3 (55,0 ± 9,5; 84,8 ± 52,1; 48,0 ± 3,7). Após a CTM: G1 20 (105,0 ± 28,2; 120,6 ± 34,0; 65,0 ± 10,8), G2 (103,5 ± 22,7; 127,3 ± 45,4; 61,9 ± 7,6), G3 (101,9 ± 6,5; 167,5 ± 37,6; 58,5 ± 4,4). Houve maior aumento da fenda marginal para o grupo G3 na região oclusal após a CTM, acima do limite aceitável clinicamente (120 µm). A fenda marginal na região proximal foi estatisticamente menor para todos os grupos após a CTM. Conclusões. O desenho do preparo para facetas cerâmicas influenciou significativamente na formação de fendas marginais após 5 anos de envelhecimento simulado. As facetas convencionais e lentes de contato apresentaram significativamente menor aumento das fendas marginais quando comparadas aos fragmentos na região oclusal, que obtiveram resultados acima do limite aceitável clinicamente. A região proximal foi a região mais estável. <br> / Abstract : The purpose of this study was to evaluate the influence of the preparation design for ceramic veneers on the immediate marginal integrity and after 5 years of simulated aging, in different regions of the tooth. Material and methods. Thirty freshly sound human superior premolars were selected and randomly divided into 3 groups (n = 10), according to the preparation design of the ceramic veneer restoration: G1/Conventional: total veneer with preparation; G2/Contact Lens: total veneer without preparation; G3/Fragment: partial veneer without preparation. The preparations for the group Conventional were controlled by means of silicone guides (vertical and horizontal, 0.5 mm buccal axial reduction). The teeth were embedded in polystyrene resin with periodontal ligament simulation. Thirty lithium disilicate ceramic restorations were produced using CAD/CAM technology with standard thickness (0.5 mm) and internal space (100 µm). Ceramic restorations were adhesively cemented and the specimens were aged with a proven thermomechanical cycling protocol (TMC) (1200000 chewing cycles, 50 N, 2 Hz, and 6000 thermal cycles, 5/55 ° C, 2 min per cycle) to simulate five years of clinical service. All specimens were scanned by micro-computed tomography (micro-CT) for 3D analysis of the marginal adaptation (µm) in three areas (cervical, proximal, occlusal) before and after the TMC. The means were calculated and data were statistically analyzed by ANOVA two factors, followed by Tukey test (a = 5%). Results. The results of marginal fit (µm) and standard deviation before TMC for cervical, 22 occlusal and proximal regions respectively were: Conventional (51.5 ± 9.4, 51.5 ± 21.8, 59.7 ± 12.9) Contact Lens (45.3 ± 9.7, 65.1 ± 11.8, 52.0 ± 7.0), Fragment (55.0 ± 9.5, 84.8 ± 52.1; 48.0 ± 3.7). After the TMC: Conventional (105.0 ± 28.2, 120.6 ± 34.0, 65.0 ± 10.8) Contact Lens (103.5 ± 22.7, 127.3 ± 45 4; 61.9 ± 7.6), Fragment (101.9 ± 6.5, 167.5 ± 37.6, 58.5 ± 4.4). The variation before and after the TMC: Conventional (53.5 ± 29.2, 69.1 ± 53.6, 5.3 ± 5.0), Contact Lens (58.2 ± 28.2; 62 2 ± 43.4, 9.9 ± 3.7), Fragment (46.9 ± 3.0, 82.7 ± 45.8, 10.5 ± 2.5). There was a significantly greater increase in marginal gap for the group Fragment in the occlusal region after the TMC, above the clinically acceptable limit of 120 µm (p < 0.05). The marginal gap in the proximal region was significantly lower for all groups after the TMC (p < 0.05). Conclusions. The preparation design for ceramic veneers significantly influenced the marginal gaps formation after 5 years of simulated aging. Conventional and contact lens veneers presented a significantly lower increase in marginal gaps compared to fragments in the occlusal region, which revealed results above the clinically acceptable limit. The proximal region was the most stable region.
|
Page generated in 0.067 seconds