41

Influencia do tipo de preparo na retenção de coroas totais e restaurações metalicas fundidas, fixadas com cimentos de ionomero de vidro convencional e modificado por resina

Martins, Fabio 17 August 1998 (has links)
Orientador: Simonides Consani / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-23T23:10:32Z (GMT). No. of bitstreams: 1 Martins_Fabio_D.pdf: 4457611 bytes, checksum: 86f57f3d95c884d43b768399a95e8c73 (MD5) Previous issue date: 1998 / Resumo: Oobjetivo deste estudo foi verificar a resistência à tração de coroas totais e restaurações de classe II MOD, cimentadas em preparos efetuados em 64 dentes molares humanos hígidos, recém-extraídos, e armazenados em soro fisiológico por 3 meses, utilizando cimento de ionômero de vidro convencional Shofu Glaslonomer e modificado por resina Vitremer 3M. Após a profilaxia, as raízes de cada dente foram incluídas em resina acrílica. A coroa foi preparada inicialmente em tomo mecânico e a fmalização do preparo foi feita com ponta diamantada em alta rotação refrigerada à água, até a obtenção de um preparo cônico para coroa total ou um preparo estilizado tipo classe II, para restaurações MOD. Em seguida, as restaurações metálicas foram obtidas com liga à base de Ni-Cr através da técnica de fundição pelo método da cera perdida. Os corpos-de-prova foram divididos em oito grupos de 8 unidades ada, sendo quatro grupos para os preparos de coroa total e quatro para os preparos de restaurações de classe II MOD, ficando metade dos grupos cimentados com cada tipo de cimento ionomérico, com e sem ciclagem térmica. A cimentação foi realizada sob carga estática compressiva de 5 kgf durante 10 minutos e os ensaios de tração numa máquina de ensaio universal Otto Wolpert-Werke (Alemanha), nuína velocidade de 6 mm/min., após 24 horas de armazenagem. Os resultados foram submetidos à análise de variância e teste de Tukey a 5% de probabilidade. Os autores concluíram que o cimento de ionômero de vidro modificado por resina Vitremer-3M obteve os maiores valores de resistência à tração em relação ao cimento de ionômero de vidro convencional Shofu Glaslonomer, em todas as situações estudadas, exceto quando as restaurações MOD sofreram tratamento térmico / Abstract: The object of this study was to verify the resistance to tension strength of total and inlays MOD metalic crowns, cemented to human teeth with glass ionomer Iutins cement Shofu GIaslonomer and resin-modified glass ionomer Iuting cement Vitremer-3M. Sixty-four sound, recently-extracted human molars were used. The dental crown of each tooth was machined initially in a mechanicalIathe until the form adequate for the preparation for a total and inlays MOD crown was obtained, Iather, "the handpiece was used to frnishthe preparation. The total and inlays MOD crowns were obtained by the 10st-waX dental casting method, using a Ni-Cr based alIoy. The prepared teeth, with their respective cast croWllS, were separed into eight groups of 8 teeth each, cemented with the two cements, with and without termical cycle. Analysis of the variations recorded, in reference to the Tukey test, showed that the average - values obtained for the eight groups did show a statistically significant diferences in the comparison of the two rpaterials, and with the two preparation, with and without tennical cyc1e. Analysing the resuIts the autours conc1uded that the resin-modified glass ionomer Iuting cement Vitremer-3M have the most resistence of tension strength in alI cases, except with inlay MOD metalic Ni-Cr crowns with termica) cycle / Doutorado / Materiais Dentarios / Doutor em Ciências
42

Estabilidade mecanica de retentores do tipo coroa total

Silva, Wilkens Aurelio Buarque e, 1967- 04 July 1995 (has links)
Orientador: Frederico Andrade e Silva / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-20T11:45:48Z (GMT). No. of bitstreams: 1 Silva_WilkensAurelioBuarquee_M.pdf: 2887452 bytes, checksum: 0b71ed157e45bf5685d0b21d1ab7f5f1 (MD5) Previous issue date: 1995 / Resumo: O objetivo deste trabalho, foi avaliar a forma de resitência, em preparos para coroas totais, com preservação dos ângulos axo-proximais, variando-se a convergência entre as paredes axiais, com e sem canaletas proximais e, sem a interposição de um meio cimentante. Foram confeccionados oitenta (80) preparos do tipo coroa total com ângulos axo-proximais em dentes naturais. Quarenta (40) com cana retas e quarenta (40) sem canaletas. Os preparos com ombro maior que 90° foram executados com as seguintes convergências: 6°, 8°, 12° e 16° em cada uma das paredes axiais com e sem canaletas axiais proximais, de 0,7mm de profundidade e 4mm de altura. A altura cérvico-oclusal dos preparos foi de 5mm e as dimensões mésio-distais e vestíbulo-linguais em 10mm e 7mm, respectivamente. Para a avaliação de resistência ao deslocamento, os corpos de prova adaptados em seus respectivos preparos, foram submetidos à cargas verticais de intensidade 3kg, 5kg, 10kg e 15kg em uma máquina de teste universal, com velocidade constante em 0,5mm/min., aplicadas nas vertentes internas das cúspides f!1ésio-linguais e médio-vestibulares. O registro dos resultados consistiu em visualizar a ocorrência ou não de deslocamento dos corpos de prova. Os resultados obtidos revelaram que: a) o aumento do ângulo de convergência entre as paredes axiais promove uma diminuição da estabilidade mecânica das coroas; b) com 6° e 8° de convergência em cada uma das paredes axiais ocorreu uma estabilidade mecânica ótima nas preparações sem canaletas; c) em 12° e 16° de convergência foi observada falta de estabilidade mecânica nas preparações sem canaletas; d) a utilização de canaletas axiais proximais constitui-se num efetivo meio para otimizar a estabilidade mecânica / Abstract: The objective of this work, was to evaluate the influence of the convergece angle between the axial walls of full crown preparations and the presence of proximal axial grooves, on the resistence form of full crows, without interlocking a cement medium. Eighty full crown preparations was màde with axo-proximal angles in natural teeth. Fourty with proximal axial grooves and fourty without proximal axial grooves. The preparations with showder larger 90° , was made with the following convergeces: 6°,8°, 12° and 16° in each of the axial walls, with and without proximal axial wals, of 0,7mm deep and 4mm high. The cervico-occlusal heigth of the preparations was 0,5mm and the mesio-distal and bucco-ligual diameters, 10mm and 7mm respectively. To evaluate the resistence form, the patterns adjusted in yours respective preparations, was submited to vertical forces of intensity 3kg, 5kg, 10kg and 15kg in a universal test machine, with speed in 0,5mm/min., applied in the internal vertent of the mesio-lingual and medio-buccal cuspals. The record of the results was to observe the occcurs of dislocation of the paterns. The obtained results shows that: a) the increase of the convergence angle promoves the decrease of the mechanical stabilty of the crowns; b) In 6° and 8° occured a optimal mechanical stability in the preparations without grooves; c) In 12° and 16° was observed the absence of stability in preparations with out grooves; d) The utilization of the proximal axial grooves is a effective option to optimize the mechanical stability, in preparations where the convergence angle is excessive / Mestrado / Protese Dental / Mestre em Clínica Odontológica
43

Resistencia flexural de ligas do sistema Co-Cr antes e apos a refusão submetidas ou não a soldagem

Henriques, Guilherme Elias Pessanha, 1968- 18 July 2018 (has links)
Orientador: Simonides Consani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-18T10:00:07Z (GMT). No. of bitstreams: 1 Henriques_GuilhermeEliasPessanha_M.pdf: 3082477 bytes, checksum: 9387401241e8fa339536480dc617cfc9 (MD5) Previous issue date: 1993 / Resumo: O objetivo deste trabalho foi avaliar a resistência flexural das ligas do sistema Co-Cr Dentorium, Duracrom e Steeldent, disponíveis comercialmente, submetendo-as ou não à soldagem, utilizando amostras confeccionadas com liga nova exclusivamente ou mistura de proporções iguais de ligas nova e previamente fundida. Foram confeccionadas vinte amostras com formato em halteres, para cada uma das ligas avaliadas, divididas em quatro grupos, seguindo o critério a seguir: liga nova sem solda; liga nova/refundida sem solda; liga nova com solda; e, liga nova/refundida com solda. As amostras foram fundidas mediante a utilização de fonte elétrica de arco voltaico de carbono e para o procedimento de soldagem, foi utilizada liga para solda de alta temperatura à base de Co-Cr, fundida sob chama redutora de maçarico de oxiacetileno, estando as partes a serem unidas, distantes 0,4 mm entre si. Para a avaliação da resistência flexural, as amostras foram submetidas à carga perpendicular de compressão fornecida por máquina de teste universal, com velocidade de 200 Kgf /min. Posteriormente, a superfície de fratura das amostras, foi analisada sob microscopia eletrônica de varredura. Com base nos resultados obtidos, verificamos que: a) as ligas Dentorium e Steeldent, tanto na condição de nova, quanto na condição de misturadas, não mostraram diferenças estatisticamente significativas em termos de resistência flexural; b) a liga Duracrom registrou redução nos valores de resistência flexural quando misturada com ligas nova e refundida; c) para as três ligas avaliadas, tanto na condição de nova como na condição de misturadas, houve redução nos valores de resistência flexural para aproximadamente 1/4 daqueles obtidos com as amostras livres de solda / Abstract: The purpose of this investigation was to determine the flexural strength of Dentorium, Duracrom and Steeldent, commercially available Co-Cr based alloys, subdued or not to soldering procedure, using only new alloy or a mixture of new and previously casted alloy. Twenty dumb-shaped specimens were manufactured for each one of the alloys, divided into four groups as the following rule: new alloy without soldering procedure; new alloy/casted alloy combination without soldering procedure; new alloy with soldering procedure; and, new alloy/casted alloy combination with soldering procedure. The specimens were cast with carbon voltaic arc as the electric heat source and for the soldering procedure, it was used high-temperature Co-Cr solder alloy, melted with the reducing flame of a oxyacetilene torch as the heat source, while the gap distance was maintained at 0.4 mm. To evaluate the flexural strength, the specimens were submited to perpendicular compression stress provided by the universal testing machine, with a c:ross-head speed of 200 Kgf/min. After that, the fracture surfaces were observed under scanhing electron microscopy. Related to the results, it was verified that: a) Dentorium and Steeldent alloys, neither as one-half new nor as a half-new/once-used combination, showed no statistically significant differences; b) Duracrom alloy showed reduced flexural strength values when conducted in the as mixed condition; c:) either as new or as mixed, the soldered three alloys displayed reduction of about 1/4 in the flexural strength values, when compared with those obtained with the non soldered ones / Mestrado / Materiais Dentarios / Mestre em Ciências
44

Efetividade da irradiação por microondas na esterilização de materiais reembasadores rígidos

Neppelenbroek, Karin Hermana [UNESP] 20 February 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:29:12Z (GMT). No. of bitstreams: 0 Previous issue date: 2003-02-20Bitstream added on 2014-06-13T19:59:00Z : No. of bitstreams: 1 neppelenbroek_kh_me_arafo.pdf: 1207398 bytes, checksum: f62bbd2bc989a956c67818a3fd010f68 (MD5) / Este estudo teve por objetivo avaliar a efetividade da irradiação por microondas na esterilização de resinas rígidas para reembsasmento imediato. Corpos-de-prova (10 x 10 x 1 mm) de três resinas reembasadoras rígidas (Kooliner, Tokuso Rebase and Ufi Gel hard) foram confeccionados e esterilizados por meio de óxido de etileno. Os corpos-de-prova foram então individualmente inoculados (107 cfu/mL) com meio de cultura de Tryptic Soy Broth (TSB) contendo um dos seguintes microorganismos: C.albicans, S. aureus, B. subtilis and P. aeruginosa. Após 48 h de incubação a 37oC, os corpos-de-porva foram agitados por 1 min e deixados em repouso por 9 min, seguido de nova agitação para suspender qualquer microrganismo aderente. Após a inoculação, 40 corpos-de-prova de cada material foram imersos em 200 mL de água e irradiados a 650W por 6 min. Quarenta corpos-de-prova não irradiados foram utilizados como controle positivo. A seguir, 25 uL da suspensão resultante das diluições seriadas de 10-3 a 10-6, foram semeados em placas de Petri contendo os meios de cultura seletivo para cada microrganismo. Todas as placas foram incubadas a 37oC por 48 h. Após a incubação, as colônias foram quantificadas em ufc/mL. Os corpos-de-prova irradiados foram imersos em meio de cultura e incubados a 37oC por 7 dias. Vinte corpos-de-prova foram preparados para microscopia eletrônica de varrredura (MEV). Todos os corpos-de-prova demonstraram efetiva esterilização após a irradiação em microondas. A análise em MEV indicou alteração na morfologia celular dos microrganismos após irradiação em microondas. Os corpos-de-prova irradiados e incubados por 7 dias não demonstram crescimento microbiológico visível no meio de cultura. A esterilização por microondas por 6 min a 650 W provou ser um método efetivo para a esterilização de resinas reembasadoras rígidas. / he aim of this study was to evaluate the effectiveness of microwave irradiation sterilization on hard chairside reline resins. Specimens (10x10x1mm) of three hard chairside reline resins (Kooliner, Tokuso Rebase and Ufigel hard) were fabricated and submitted to ethylene oxide sterilization. The specimens were then individually inoculated (107 cfu/mL) with Tryptic Soy Broth media containing one of the tested microorganisms (C.albicans, S. aureus, B. subtilis and P. aeruginosa). After 48 hours at 37 oC, the samples were vortexed for 1 minute and allowed to stand for 9 minutes followed by a short vortex to resuspend any organisms present. After inoculation, forty specimens of each material were immersed in 200 millilitres of water and submitted to microwave irradiation at 650 Watts for 6 minutes. Forty non-irradiated specimens were used as positive controls. Replicate specimens (25 microlitres) of suspension were plated at dilutions of 10-3 to 10-6 on plates of selective media appropriate for each organism. All plates were incubated at 37 oC for 48 hours. After incubation, colonies were counted (cfu/mL) and the data were statistically analyzed by the Kruskal-Wallis's test. Twelve specimens of each material were prepared for Scanning Electronic Microscopy (SEM). All immersed specimens showed consistent sterilization of all the individual organisms after microwave irradiation. SEM examination indicated an alteration in cell morphology after microwave irradiation. Microwave sterilization for 6 minutes at 650 Watts proved to be an effective method for the sterilization of hard chairside reline resins.
45

Efetividade da irradiação por microondas na esterilização de materiais reembasadores rígidos /

Neppelenbroek, Karin Hermana. January 2003 (has links)
Resumo: Este estudo teve por objetivo avaliar a efetividade da irradiação por microondas na esterilização de resinas rígidas para reembsasmento imediato. Corpos-de-prova (10 x 10 x 1 mm) de três resinas reembasadoras rígidas (Kooliner, Tokuso Rebase and Ufi Gel hard) foram confeccionados e esterilizados por meio de óxido de etileno. Os corpos-de-prova foram então individualmente inoculados (107 cfu/mL) com meio de cultura de Tryptic Soy Broth (TSB) contendo um dos seguintes microorganismos: C.albicans, S. aureus, B. subtilis and P. aeruginosa. Após 48 h de incubação a 37oC, os corpos-de-porva foram agitados por 1 min e deixados em repouso por 9 min, seguido de nova agitação para suspender qualquer microrganismo aderente. Após a inoculação, 40 corpos-de-prova de cada material foram imersos em 200 mL de água e irradiados a 650W por 6 min. Quarenta corpos-de-prova não irradiados foram utilizados como controle positivo. A seguir, 25 uL da suspensão resultante das diluições seriadas de 10-3 a 10-6, foram semeados em placas de Petri contendo os meios de cultura seletivo para cada microrganismo. Todas as placas foram incubadas a 37oC por 48 h. Após a incubação, as colônias foram quantificadas em ufc/mL. Os corpos-de-prova irradiados foram imersos em meio de cultura e incubados a 37oC por 7 dias. Vinte corpos-de-prova foram preparados para microscopia eletrônica de varrredura (MEV). Todos os corpos-de-prova demonstraram efetiva esterilização após a irradiação em microondas. A análise em MEV indicou alteração na morfologia celular dos microrganismos após irradiação em microondas. Os corpos-de-prova irradiados e incubados por 7 dias não demonstram crescimento microbiológico visível no meio de cultura. A esterilização por microondas por 6 min a 650 W provou ser um método efetivo para a esterilização de resinas reembasadoras rígidas. / Abstract: he aim of this study was to evaluate the effectiveness of microwave irradiation sterilization on hard chairside reline resins. Specimens (10x10x1mm) of three hard chairside reline resins (Kooliner, Tokuso Rebase and Ufigel hard) were fabricated and submitted to ethylene oxide sterilization. The specimens were then individually inoculated (107 cfu/mL) with Tryptic Soy Broth media containing one of the tested microorganisms (C.albicans, S. aureus, B. subtilis and P. aeruginosa). After 48 hours at 37 oC, the samples were vortexed for 1 minute and allowed to stand for 9 minutes followed by a short vortex to resuspend any organisms present. After inoculation, forty specimens of each material were immersed in 200 millilitres of water and submitted to microwave irradiation at 650 Watts for 6 minutes. Forty non-irradiated specimens were used as positive controls. Replicate specimens (25 microlitres) of suspension were plated at dilutions of 10-3 to 10-6 on plates of selective media appropriate for each organism. All plates were incubated at 37 oC for 48 hours. After incubation, colonies were counted (cfu/mL) and the data were statistically analyzed by the Kruskal-Wallis's test. Twelve specimens of each material were prepared for Scanning Electronic Microscopy (SEM). All immersed specimens showed consistent sterilization of all the individual organisms after microwave irradiation. SEM examination indicated an alteration in cell morphology after microwave irradiation. Microwave sterilization for 6 minutes at 650 Watts proved to be an effective method for the sterilization of hard chairside reline resins. / Orientador: Ana Cláudia Pavarina / Coorientador: Denise Madalena Palomari Spolidorio / Banca: Carlos Eduardo Vergani / Banca: Maria da Glória Chiarello de Mattos / Mestre
46

Avaliação da posição condilar em pacientes desdentados totais portadores de dentaduras duplas, através de planigrafias da ATM

Porto, Vinícius Carvalho 25 April 2000 (has links)
A posição condilar tem sido questionada como importante fator na detecção de sinais e sintomas de DTM,s. Por muito tempo, determinou-se que a concentricidade condilar refletiria uma posição ótima para o paciente. No entanto, outros trabalhos mostraram que era possível a visualização da descentralização dos côndilos, mesmo em pacientes assintomáticos. Dessa forma, avaliou-se neste trabalho a posição condilar antes e após instalação de PT,s novas, por meio de planigrafias laterais da ATM. O critério de seleção dos pacientes foi aleatório e, mediante a amostra escolhida, foi preenchido um questionário clínico-anamnésico, seguido de tomadas radiográficas com o par de dentaduras antigas e novas em 12 pacientes. Um único examinador conduziu o preenchimento das fichas e análise das radiografias no programa de imagens Corel Draw 8. De acordo com a metodologia aplicada e análise estatística dos resultados, verificou-se que a posição condilar em desdentados totais na primeira tomada radiográfica situou-se mais para anterior em 100% dos casos. Já o deslocamento condilar após instalação das novas próteses resultou em uma tendência de deslocamento para posterior em 75% dos indivíduos, para anterior em 16,7% e em 8,3% não houve variação da posição condilar. Dos 18 côndilos (75% casos) com deslocamento para posterior, apenas 1 côndilo assumiu uma posição levemente posterior, tendo os demais se localizado concentricamente ou para anterior. Não houve qualquer correlação estatisticamente significativa entre variações das posições condilares e dimensões verticais de oclusão. Provavelmente, os deslocamentos condilares encontrados sejam justificados pelas manipulações com forças variadas, aplicada pelos profissionais, para a posição de trabalho (RC). Baseado na literatura, a tendência de localização para posterior possivelmente não irá causar danos aos pacientes, tendo em vista se tratarem de indivíduos assintomáticos. / Condyle position have been questioned as a relevant factor in detection of signs and symptoms of TMD. For a long time, it was determined that condylar concentricity would reflect an ideal position for the pacient. However, others studies demonstrated that it was possible to visualize that condyles were not always concentic in assintomatic pacient. This study evaluated the condylar position before and after instalation of new complete dentures using plain tomography of TMJ,s. Twelve completely edentulous patients were selected randomly to have new complete dentures. A questionare was filled out and plain tomograms were taken with old and new complete dentures inserted. Only one examiner evaluated the questionare and tomograms using Corel Draw 8 image software. According to the metodology and statical analysis, it was noted that condyle position in completely edentulous patients in the first tomogram was anterior in 100% of patients. After insertion of new dentures, the condyles had a tedency to be posteriorly positioned relative to the initial tomogram in 75% of the, 16,7% of the condyles deslocated anteriorly, and in 8,3% did not change position. Of the 18 condyles (75% of total) with posterior displacement, only one condyle assumed a true, although slight, posterior position, with the others located in a concentric or anterior position. There was no any statical correlation between variation of condylar position and vertical dimension of occlusion. Probably, the condylar displacement occurred due to variations in the manipulation technique applied by the professionals for centric relation registration. Base on the literature, the tendency to posterior location of condyles of completely edentulous patients after new complete dentures insertion will not cause any damage in assintomatic patients.
47

Avaliação da resistência ao cisalhamento de três sistemas de núcleos intra-radiculares

Xible, Anuar Antônio 26 April 2000 (has links)
Foram comparadas as resistências adesivas ao cisalhamento presente entres os componentes de três diferentes sistemas de núcleos intra-radiculares. Foram utilizados pinos de cerâmica à base de dióxido de zircônia ( Cosmopost ), e pinos de titânio ( Tenax ). Os preenchimentos testados foram a resina composta fotopolimerizável ( Tetric Ceram ) e porcelana vítrea fundível ( IPS Empress Post ). Foram confeccionados 30 espécimes divididos em 03 grupos: 10 espécimes de pinos de cerâmica à base de zircônia, aos quais foi fundida porcelana vítrea; 10 espécimes de pinos de cerâmica à base de zircônia e resina composta fotopolimerizável; e 10 espécimes de pinos de titânio e resina composta fotopolimerizável, todos, de acordo com o fabricante. Os espécimes do grupo 1 necessitaram ser ajustados, por desgaste, à base de prova. Todos foram submetidos a uma força de cisalhamento em uma máquina de ensaios universal Kratos, até fratura. A análise estatística, assim como observações macroscópicas permitiu-nos concluir que: 1- A resistência encontrada entre os componentes dos corpos de prova do grupo Pino de Zircônia X Cerâmica IPS Empress Post apresentou resultados estatisticamente não significantes em relação ao grupo em que foi usado Pinos de Titânio X Resina composta. 2- Os resultados dos sistemas do grupo 1 - Pino de Zircônia X Cerâmica IPS Empress Post - e 3 - Pinos de Titânio X Resina Composta demonstraram diferença estatisticamente significante em relação ao grupo 2, em que foi empregado o sistema dos Pinos de Zircônia X Resina Composta. / The purpose of the present study was to evaluate shear bond strength in three different posts and core systems. Thirty standardized cylindrical cores with 4mm height and 6mm diameter were prepared surrounding the posts in a special prefabricated device. They were divided in three groups. Group 1 was composed of 10 zirconia posts ( Cosmopost – Ivoclar ), which were placed in a special device. Cylinders were waxed surrounding them. The patterns were then invested and glass-ceramic ( Empress Cosmo – Ivoclar ) was heat-pressed in a EP500 furnace ( Ivoclar ). Group 2 consisting of 10 zirconia posts ( Cosmopost – Ivoclar ) adapted in the device and composite ( Tetric Ceram – Ivoclar ) was inserted and then light activated. Group 3 consisting of titanium posts ( Tenax – Whaledent ) was adapted in the same device as group 1 and 2. The same composite was inserted and also light activated. Specimens were tested for shear bond strength in a Kratos universal test machine. Results showed no statistical differences between groups 1 and 3 but significant difference between group 2 and the others. According to above results, it was concluded that systems used in groups 1 and 3 are the most reliable in clinical applications.
48

Estudo das microdeformações geradas ao redor de implantes de hexágono interno com roscas convencionais e implantes com platôs, sob a aplicação de carga vertical

Santos, Vivian Mayumi Miyazaki [UNESP] 24 July 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:57Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-07-24Bitstream added on 2014-06-13T20:58:50Z : No. of bitstreams: 1 000758021.pdf: 2255697 bytes, checksum: 6788d35fffb3b6caf3a72279e1182869 (MD5) / O objetivo deste estudo foi avaliar a micro deformação ao redor de implantes hexágono interno e implantes com roscas platô sob carregamento vertical. Foram confeccionados 10 blocos de poliuretano com 190X30X12 mm. Na face de menor largura e maior comprimento de cada bloco foi inserido um implante de cada sistema (implante hexágono interno de 4 mm X 8,5 mm e implante platô de 4,5 mm X 8 mm) que depois receberam um pilar com 10 mm de altura. O pilar do implante hexágono interno recebeu torque de 20 N com auxilio de torquímetro manual, enquanto o pilar do implante platô foi inserido no implante com o auxilio de martelete. Quatro extensômetros foram colados ao redor dos implantes. Também foram colados extensômetros na lateral do bloco na região do terço médio e apical dos implantes. Os implantes foram submetidos a uma carga vertical estática de 30 Kg. Os dados foram submetidos a análise estatística ANOVA e Tukey (5%). Foi verificado que houve diferença estatística significante para a região cervical (horizontal) dos implantes em relação à região média e apical (vertical), sendo o P=0.0259. Com o teste Tukey, foi verificado que a região horizontal dos implantes platôs apresentaram uma maior micro deformação em relação a região vertical e da região horizontal e vertical dos implantes hexágono interno. Pode-se concluir que o implante platô demonstrou maior micro deformação do que o implante hexágono interno, a região cervical obteve uma maior concentração de tensões em relação à região do terço médio e apical e que o tipo de conexão pilar/implante interfere na micro deformação distribuída ao redor do implante / The aim of the study was to evaluate the micro strain around internal hexagon implant and plateau screws implant under vertical load. 10 polyurethane blocks were produce with 190X30X12 mm. On the narrower face of each block was inserted in each system implant (internal hexagon implant 4 mm X 8,5 mm and plateau implant 4,5 mm X 8 mm) which then received one abutment with 10 mm high. The internal hexagon abutment received torque of 20 N with aid manual torquemeter and plateau abutment was inserted with surgical mallet. Four strain gauge were bonded around of the implants. Also the strain gauges were bonded in the lateral block in the middle and apical region implants. The implants were subjected to a static vertical load of 30 kg. The data were submitted to ANOVA and Tukey (5%). It was found that there was statistically significant difference for the cervical region (horizontal) of the implants to the middle and apical region (vertical), with P = 0.0259. In the Tukey test, it was found that the horizontal region of the plateau implants was higher micro strain than vertical region of the plateau implants and horizontal and vertical region of the internal hexagon implants. It concluded that the implant had a higher plateau micro strain of the implant internal hexagon, the cervical region showed a higher stress concentration towards the region of the middle and apical, and the connection type abutment/implant interferes with micro strain distributed around the implant
49

Avaliação in vitro da influência de cargas axiais em próteses parciais fixas implanto-suportadas, por meio da extensometria

Vasconcellos, Luis Gustavo Oliveira de [UNESP] 26 June 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-06-26Bitstream added on 2014-06-13T18:35:16Z : No. of bitstreams: 1 vasconcellos_lgo_me_sjc.pdf: 497389 bytes, checksum: d4adcb9c1b4650eff9f123f6b41bceab (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi avaliar in vitro, por meio da extensometria, a influência da aplicação de cargas axiais em próteses parciais fixas de 3 elementos, suportadas por implantes de conexão hexágono interno (HI), variando o tipo de cilindro e o ponto de aplicação de carga. Inicialmente foram inseridos, em disposição linear, três implantes de HI em um bloco de poliuretano. Em seguida, pilares protéticos microunit foram conectados aos implantes com torque de 20Ncm, e sobre estes foram parafusados cilindros usinados de Co-Cr e cilindros plásticos, as quais receberam enceramentos padronizados que foram posteriormente fundidos em liga de Co-Cr (n=5). Quatro extensômetros (SG) foram colados na superfície do bloco, tangenciando os implantes visando mensurar a microdeformação peri-implantar no momento da aplicação das cargas. Cada estrutura metálica foi parafusada sobre os pilares protéticos com torque de 10Ncm e a seguir foi realizada a aplicação de carga axial de 30kg em 5 pontos pré-determinados. Os dados obtidos na extensometria foram submetidos aos testes estatísticos ANOVA e Tukey (α=5%). Os resultados mostraram diferença estatisticamente significante para o ponto de aplicação de carga (p=0,0001), sendo que o ponto B gerou a menor microdeformação (239,49με) e o ponto D a maior microdeformação (442,77με). Com relação ao tipo de cilindro, não foi observada diferença estatisticamente significante (p=0,748). Concluiu-se que o tipo de cilindro não interferiu na magnitude da microdeformação peri-implantar durante a aplicação de cargas axiais e que a localização da aplicação de carga axial influenciou a magnitude desta microdeformação. / The aim of this study was to evaluate in vitro, by means of strain gauge analysis, the influence of aplication of axial loading in three-units fixed partial prostheses, supported by implants with internal hexagon connection (IH), varying the type of cylinders, and the point of load application. Three fixtures IH were inserted in linear arrangement, into a polyurethane block. Microunit abutments were connected to implants with torque of 20Ncm. The framework were fabricated as a one piece casting using plastic burn out components and Co-Cr prefabricated cylinders components (n=5). Four strain gauge were bonded around the microunit abutments on block surface to measure the peri-implant microstrain at the time of application of loads. Each framework was tight on the abutments with torque of 10Ncm and then was made the application of axial load of 30kg in 5 points pre-determined. The data obtained in the strain gauge analysis were submitted to the statistical tests ANOVA and Tukey (α=5%). The results showed a statistically significant difference to the point of application of load (p = 0.0001), whereas the point B has generated the lowest microstrain (239.49 με) and the point D has provided the highest microstrain (442.77 με). Regarding the type of cylinder, statistically significant difference was not observed (p = 0.748). It was concluded that the type of cylinder did not interfere on the magnitude of peri implant microstrain during the application of axial loads and that the location of the application of axial load influenced the magnitude of this microstrain.
50

Análise da contaminação microbiana de dispositivos acrílicos confeccionados em laboratórios de prótese dentária / Analysis of microbial contamination of device acrylic manufactured in dental laboratories

Temóteo, Guilherme de Alencar January 2014 (has links)
TEMÓTEO, Guilherme de Alencar. Análise da contaminação microbiana de dispositivos acrílicos confeccionados em laboratórios de próteses dentárias. 2014. 53 f. Dissertação (Mestrado em Odontologia) - Universidade Federal do Ceará. Faculdade de Farmácia, Odontologia e Enfermagem, Fortaleza, 2014. / Submitted by denise santos (denise.santos@ufc.br) on 2014-07-21T11:40:44Z No. of bitstreams: 1 2014_dis_gatemoteo.pdf: 741240 bytes, checksum: 21d11cc77cd7f873fb211cafff0f6596 (MD5) / Approved for entry into archive by denise santos(denise.santos@ufc.br) on 2014-07-21T11:50:50Z (GMT) No. of bitstreams: 1 2014_dis_gatemoteo.pdf: 741240 bytes, checksum: 21d11cc77cd7f873fb211cafff0f6596 (MD5) / Made available in DSpace on 2014-07-21T11:50:50Z (GMT). No. of bitstreams: 1 2014_dis_gatemoteo.pdf: 741240 bytes, checksum: 21d11cc77cd7f873fb211cafff0f6596 (MD5) Previous issue date: 2014 / The possible presence of potentially pathogenic microorganisms in denture newly arrived from prosthetic laboratories should be considered. This study evaluated the level of bacterial and fungal contamination of specimens of acrylic resin made in 14 dental laboratories registered with the Regional Council of Dentistry of Ceará, Fortaleza. Each laboratory was asked to fabricate 10 specimens of acrylic resin, from standard models of sterile silicone addition, unaware of the research objectives. Specimens received from laboratories were placed in individual tubes containing BHI broth, incubated at 37°C for 48 hours and then removed, washed and placed in sterile saline and stirred for microbial detachment. The suspension obtained was diluted (1:100, 1:1000) and plated on blood agar plates, and Sabouraud Dextrose Agar and Agar HiCrome ICU by incubation for 48 hours at 37°C. The number of colony forming units (CFU) bacterial and fungal viable was obtained, besides the identification and quantification of some species of bacteria, comparing the laboratory by means of the Kruskal-Wallis and Dunn (α = 0.05) tests. There was contamination originating from all laboratories analyzed, with a mean CFU counts of 101438 bacteria and 71047 fungi. Pseudomonas spp was the most prevalent microorganism identified (p < 0.05). It was concluded that there is a risk of contamination with potentially pathogenic bacteria and fungi in prosthetic devices newly arrived from dental laboratories. / A possível presença de microorganismos potencialmente patogênicos em próteses dentárias recém-chegadas dos laboratórios protéticos deve ser considerada. Este estudo avaliou o nível de contaminação bacteriana e fúngica de espécimes de resina acrílica confeccionados em 14 laboratórios de prótese dentária, inscritos no Conselho Regional de Odontologia do Ceará, na cidade de Fortaleza. Cada laboratório foi solicitado a confeccionar 10 espécimes de resina acrílica, a partir de modelos padronizados de silicona de adição estéreis, desconhecendo os objetivos da pesquisa. Os espécimes recebidos dos laboratórios foram colocados em tubos individuais contendo BHI caldo e incubados a 37°C por 48 horas e, em seguida, removidos, lavados, colocados em solução salina estéril e agitados para desprendimento microbiano. A suspensão obtida foi diluída em 1:100, 1:1000 e semeada em placas com Ágar Sangue, Sabouraud Dextrose Ágar e HICrome UTI Ágar®, para incubação por 48 horas a 37°C. Foi obtido o número de unidades formadoras de colônias (UFC) bacterianas e fúngicas viáveis, além da identificação e quantificação de algumas espécies de bactérias, comparando-se os laboratórios por meio dos testes de Kruskall-Wallis e Dunn (α=0.05). Houve contaminação advinda de todos os laboratórios analizados, com uma contagem de UFC média de 101438 de bactérias e 71047 de fungos. Pseudomonas spp foi o microorganismo a mais prevalente identificado (p<0,05). Foi concluido que existe risco de contaminação por bactérias potencialmente patogênicas e fungos em dispositivos protéticos recém chegados dos laboratórios.