• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1509
  • 69
  • 69
  • 69
  • 69
  • 49
  • 17
  • 11
  • 11
  • 10
  • 7
  • 5
  • 3
  • 2
  • 2
  • Tagged with
  • 1536
  • 774
  • 497
  • 457
  • 365
  • 347
  • 292
  • 240
  • 219
  • 198
  • 187
  • 185
  • 175
  • 168
  • 141
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
181

Avaliação da força mastigatória e da atividade eletromiográfica dos músculos masseter e temporal em função de diferentes tratamentos reabilitadores

Gomes, Isabela Silva [UNESP] 13 July 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-07-13Bitstream added on 2014-06-13T20:31:06Z : No. of bitstreams: 1 gomes_is_me_sjc.pdf: 801296 bytes, checksum: 2526ffb1511ce379c2b5d5a4874f5b70 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A função mastigatória é um dos mais complexos mecanismos neuropsicológicos no desempenho motor humano, dependendo de vários fatores como força de mordida, coordenação dos músculos, morfologia e número de dentes em oclusão. O objetivo desse trabalho é quantificar a força mastigatória máxima e analisar eletromiograficamente os músculos elevadores mandibulares de pacientes dentados totais (n=52) e reabilitados com prótese total (PT) (n=28) e prótese parcial removível (PPR) (n=27), a fim de verificar a influência de diferentes tratamentos reabilitadores na força mastigatória e atividade dos músculos masseter e temporal. A coleta dos dados de força de mordida (FM) e atividade eletromiográfica (EMG) foi realizada em triplicata em repouso e em contração isométrica através de um transdutor de força de mordida (desenvolvido pelos autores) e um eletromiógrafo EMG-800c de oito canais (EMG System do Brasil Ltda). Outras variáveis como gênero, idade, peso, estresse, prática de atividade física, lado preferencial da mastigação, formato facial e consistência da alimentação também foram levantadas e comparadas às variáveis FM e EMG em função dos grupos experimentais. Os valores de força de mordida (em Kgf) e os sinais eletromiográficos (em voltagem RMS) dos músculos masseter e temporal direito e esquerdo foram submetidos à estatística descritiva e comparados em função dos grupos experimentais por meio do teste estatístico de Análise de Variância 1 fator (ANOVA) e ao teste Tukey com nível de significância de 5%. Com relação à FM, o grupo controle (51,49 ± 16,24)A apresentou média estatisticamente superior (p=0,00<0,05) ao grupo PPR(28,45 ± 15,43)B e PT (13,11 ± 7,69)C . Com relação à EMG, em repouso... / The chewing is one of the most complex neuropsychological mechanisms in human motor performance, depending on various factors such as bite force, muscle coordination, morphology and number of teeth in occlusion. The aim of this study is to quantify the maximum bite force and analysis electromyographic of the jaw elevators muscles of dentate patients (n = 52) and rehabilitated with complete denture (CD) (n = 28) and removable partial dentures (RPD) (n = 27) in order to check the influence of different rehabilitation treatments in bite force and activity of the masseter and temporal. Data collection of bite force (BF) and electromyographic activity (EMG) was performed in triplicate at rest and during isometric contraction with a bite force transducer (developed by the authors) and an electromyograph EMG-800c eight-channel (EMG System do Brazil Ltda.) Other variations such as gender, age, weight, stress, physical activity, preferred side of chewing, facial shape and consistency of supply were also raised compared to variables BF and EMG as a function of the experimental groups. The values of bite force (kgf) and the electromyographic signals (RMS voltage) of the masseter and temporal right and left were subjected to descriptive statistics and compared on the basis of the experimental groups using the statistical test of a factor analysis of variance (ANOVA) and Tukey's test at a significance level of 5%. With respect to BF, the control group (51.49 ± 16.24) had statistically significant higher (p = 0.00 <0.05)A than PPR group (28.45 ± 15.43)B and PT (13 , 11 ± 7.69)C. Regarding the EMG at rest showed no statistical difference between any of the muscles (p> 0.05). In isometric contraction, however, the control group... (Complete abstract click electronic access below)
182

Artroplastia total híbrida nacional em cães Portadores de displasia coxofemoral

Rossetto, Victor José Vieira [UNESP] 16 March 2015 (has links) (PDF)
Made available in DSpace on 2016-06-07T17:12:13Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-03-16. Added 1 bitstream(s) on 2016-06-07T17:16:48Z : No. of bitstreams: 1 000859208_20170316.pdf: 96768 bytes, checksum: 4cbdf569b6df05c1b8d5b67b81321f18 (MD5) Bitstreams deleted on 2017-03-17T12:38:07Z: 000859208_20170316.pdf,. Added 1 bitstream(s) on 2017-03-17T12:39:08Z : No. of bitstreams: 1 000859208.pdf: 738633 bytes, checksum: c7ad09705495ab495cb631dcdc05db78 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / A artroplastia total coxofemoral de uma maneira geral é a técnica cirúrgica mais indicada para o tratamento da displasia coxofemoral grave em humanos e cães, e consiste na substituição das extremidades ósseas que compõem a articulação por componentes protéticos. O objetivo do presente trabalho foi avaliar a artroplastia total modular híbrida, desenvolvida no Brasil, como opção de tratamento para casos de displasia coxofemoral moderada ou grave até 180 dias de pós-operatório, bem como a frequência das suas potenciais complicações. Para isso, foram utilizados 10 animais da espécie canina, de raças variadas, esqueleticamente maduros, machos e fêmeas, portadores de displasia coxofemoral moderada ou grave, e submetidos ao procedimento de artroplastia total utilizando-se componente femoral cimentado de cabeça intercambiável e componente acetabular não cimentado. Os cães foram avaliados por meio de exames ortopédico e radiográfico no período pósoperatório imediato, e aos 30, 60, 120 e 180 dias após a cirurgia; e exame tomográfico no período pós-operatório imediato, e aos 120 e 180 dias de pós-operatório. Com relação à avaliação da função locomotora e intensidade de dor, o procedimento cirúrgico conferiu melhora em, respectivamente, 60% e 90% dos animais avaliados. Dentre os animais selecionados, seis (60%) apresentaram complicações pós-operatórias. As principais complicações verificadas incluíram infecção, soltura asséptica do componente acetabular, luxação do componente femoral em relação ao acetabular e fratura femoral periprostética. A seleção dos proprietários e animais deve ser rigorosa na tentativa de reduzir sobremaneira as complicações verificadas / Total hip arthroplasty is generally the most commonly performed surgical technique for severe hip dysplasia treatment in humans and dogs, and consists of the replacement of the hip joint by prosthetic components. The aim of this study was to evaluate the hybrid total arthroplasty, developed in Brazil, as a treatment option for dogs with moderate or severe hip dysplasia up to 180 days after surgery by clinical, radiographical and tomographical evaluations, and the frequency of the potential complications. For this, we utilized 10 dogs of variable breeds, skeletally mature, male and female, with moderate or severe hip dysplasia and submitted to total hip arthroplasty using cemented femoral component of exchangeable head and cementless acetabular component. The dogs were evaluated by orthopaedic and radiographical examinations at imediate postoperative period, and at 30, 60, 120 and 180 days after surgery; and by CT scan at imediate postoperative period, and at 120 and 180 days after surgery. Surgery conferred improvement of the locomotor function and intensity of pain in, respectively, 60% and 90% of the evaluated animals. Among the selected animals, six (60%) had postoperative complications. Major complications included infection, aseptic loosening of the femoral component, femoral component dislocation and femoral periprosthetic fracture. The selection of owners and animals must be rigorous in trying to greatly reduce the complications observed
183

Retorque de parafusos de pilares protéticos com recobrimento de carbono tipo diamante: uma análise da manutenção do torque após fadiga mecânica

Canavezi, Rafaela Cristiane [UNESP] 10 December 2015 (has links) (PDF)
Made available in DSpace on 2016-06-07T17:12:32Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-12-10. Added 1 bitstream(s) on 2016-06-07T17:17:17Z : No. of bitstreams: 1 000865436.pdf: 1601189 bytes, checksum: c34e3709b85d75f0d4c7ed707ac9c2a8 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Esta pesquisa se propôs verificar a manutenção do torque, após fadiga mecânica, de parafusos de pilares protéticos com recobrimento de carbono tipo diamante (DLC) e com dopagem de diamantes (CD-DLC) submetidos ao retorque, em conexões hexagonais externa (HE) e interna (HI). Implantes HE e HI e diferentes tratamentos do parafuso protético foram alocados em grupos experimentais (n = 5): sem tratamento e não submetidos a fadiga (HE-CON) (HI-CON); sem tratamento fadigados (HECONF) (HI-CONF); com DLC fadigado (HE-DLCF) (HI-DLCF) e com CDDLC fadigados (HE-CD-DLCF) (HI-CD-DLCF). Os recobrimentos de DLC e CD-DLC foram depositados a plasma pelo método PECVD. As amostras (implante + parafusos + coroa metálica), que já haviam sido expostas a 1 milhão de ciclos de fadiga, foram retorqueadas com torquímetro digital, com o torque recomendado pelo fabricante 30 N (HE) e 20 N (HI), e submetidos novamente a 1 milhão de ciclos mecânicos. Ao término da fadiga, os parafusos foram destorqueados para verificar a manutenção do torque. Parafusos de cada grupo experimental foram selecionados para observação em MEV. A análise estatística foi realizada pelo teste Anova 2- Fatores (α = 0,05). Não houve interação entre os fatores em estudo (p = 0,765); o tratamento dos parafusos (p = 0,638) e o tipo de conexão (p = 0,615) não apresentaram diferença estatística. Alterações como danos nas roscas do parafuso e remoção do filme foram observados entre os grupos experimentais. Os grupos com revestimento apresentaram pouco ou nenhum dano nas roscas dos parafusos. O revestimento de DLC e CDDLC parece não ter interferido na adaptação do parafuso ao implante. Parafusos protéticos recobertos com DLC e CD-DLC, após o retorque, não elevaram a manutenção do torque / The study analyzed the torque maintain of the screw abutments, with coating of diamond-like carbon (DLC) and doping of diamond (CD-DLC), submitted the retorque in external hexagonal (EH) and internal (IH) connections; after mechanical fatigue. HE and HI implants and different treatments of the abutments screws were divided into experimental groups (n = 5): untreated and not subjected to fatigue (EH-CON) (IHICON); fatigued untreatment (EH-CONF) (IH-CONF); fatigued with DLC (EH- DLCF) (IH-DLCF) and fatigued with CD-DLC (EH-CD-DLCF) (IH-CD-DLCF). The DLC and CD-DLC coating was deposited by plasma, PECVD method. Samples (Implant + abutment screew + metal crown), which had been exposed to 1 million fatigue cycles were retorquiadas, digital torque wrench, to the torque recommended by the manufacturer 30 N (HE) and 20 N (HI), and submitted again to 1 million cycles mechanics. At the end of fatigue, the screws were destorquiados to check the maintenance of torque. Screws from each experimental group were selected for observation by SEM. Statistical analysis was performed by ANOVA 2 Factors test (α = 0.05). There was no interaction among the factors studied (p = 0.765); the treatment of screws (p = 0.638) and the connection type (p = 0.615) showed no statistical difference. The microscopy images showed damage the threads and covering the presence of HI connections. Changes such as damage on the screws threads and film removal were observed among the experimental groups. The coating groups showed little or no damage on the screws threads. The DLC and CD-DLC coating did not interfere in the screw adaptation on the implant. Abutments screew coating with DLC and CD-DLC, after retorque, no raised torque maintenance
184

Análise comparativa das tensões e deformações entre próteses implantossuportadas de três elementos com dois ou três pilares / Stress and strain distribution around dental prostheses supported by two or tree implants

Nishioka, Gabriela Nogueira de Melo [UNESP] 30 November 2016 (has links)
Submitted by GABRIELA NOGUEIRA DE MELO NISHIOKA null (gabriela.nogueira.nishioka@gmail.com) on 2017-01-19T13:54:56Z No. of bitstreams: 1 Gabriela Nishioka.pdf: 2137589 bytes, checksum: 86ee2622125d947111a3e7089e8be313 (MD5) / Approved for entry into archive by Juliano Benedito Ferreira (julianoferreira@reitoria.unesp.br) on 2017-01-24T16:20:28Z (GMT) No. of bitstreams: 1 nishioka_gnm_me_sjc.pdf: 2137589 bytes, checksum: 86ee2622125d947111a3e7089e8be313 (MD5) / Made available in DSpace on 2017-01-24T16:20:28Z (GMT). No. of bitstreams: 1 nishioka_gnm_me_sjc.pdf: 2137589 bytes, checksum: 86ee2622125d947111a3e7089e8be313 (MD5) Previous issue date: 2016-11-30 / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / O objetivo deste estudo foi avaliar as tensões e deformações in vitro, por meio da fotoelasticidade e da extensometria, em próteses parciais fixas implantossuportadas de três elementos variando o número de pilares: dois e três. O primeiro bloco de poliuretano (modelo mestre 1) recebeu três implantes e o segundo (modelo mestre 2) recebeu dois implantes, todos de hexágono externo. Em seguida, os modelos mestre foram duplicados em resina fotoelástica. Pilares protéticos microunit foram conectados aos implantes com torque de 20 Ncm. Sobre os pilares protéticos dos modelos mestre foram parafusados cilindros plásticos, que receberam estruturas em padrões de resinas, os quais foram fundidos em liga de Ni-Cr (n=10). Quatro extensômetros foram colados na superfície de cada bloco de poliuretano, tangenciando os implantes. Nos modelos mestre e nos modelos fotoelásticos, cada estrutura metálica foi parafusada sobre os pilares protéticos com torque de 10 Ncm. Os dados obtidos na extensometria foram submetidos aos testes estatísticos RM ANOVA e Tukey (5%). As franjas isocromáticas obtidas nos modelos fotoelásticos após cada condição de carga foram registradas com uma câmera digital, visualizadas em um programa de computador e comparadas qualitativamente. Resultados: Houve uma diferença estatística significante entre a quantidade de suporte de uma prótese fixa (p=0,001). Os resultados revelaram que três implantes apresentaram uma melhor distribuição das cargas em qualquer ponto analisado e que a região de pôntico da prótese é o local que apresenta maior diferença na quantidade de deformação (2326,95με para 2 implantes e 1006,57με para 3 implantes). Nas imagens fotoelásticas foi possível visualizar uma melhor distribuição das tensões no bloco com 3 implantes. Conclusão: Ambos os métodos apresentaram resultados similares. Esse estudo sugere que uma prótese fixa pode ser suportada por 2 ou 3 implantes. / The present study used photoelastic and strain gauge analysis to compare stress and microstrain to perform an in vitro evaluation of the effect of the numbers of support in a implant-supported fixed partial prostheses with tree elements. The first polyurethane block (master model 1) will contain three implants and the second block (model 2) two of them, all implants have a external hexagon. Then, the master models were duplicated in photoelastic resin. Microunit abutments were connected to the implants and received a 20 Ncm torque. Over the master model plastic prosthetic cylinders were screwed the abutments that received standard patterns cast in Ni-Cr alloy (n=10). Four strain gauges (SG) were bonded in the surface of the block, tangentially to the lateral implants. On the master model and photoelastic model, each metallic structure were screwed onto the abutments with a 10 Ncm torque. The data obtained from the strain gauge were analyzed statistically by RM ANOVA and Tukey's test, with a 5% conventional level of significance. The isochromatic fringes obtained in the photoelastic models after each load condition were recorded with a digital camera, visualized with software to facilitate qualitative analysis. Results: There was statistically significant differences in support of FPD( p=0,001).The results demonstrated that 3 implants has higher stress distribution and in the pontic of FPD we found higher stress (2326,95με in 2 implants and 1006,57με in 3 implants).In photoelastic images, 3 implants presented better stress distribution than 2 implants. Conclusions: Both methods found similar results. This study suggests that FPD can be supported by two or three implants.
185

Avaliação das microdeformações ao redor de implantes, na utilização de pilares protéticos retos e angulados 17° e 30°, sob a influência de aplicação de cargas / Evaluation micro strain around implants in the use of straight and angled abutments 17° and 30°, under the influence of loads

Rodrigues, Vinícius Anéas [UNESP] 02 August 2017 (has links)
Submitted by vinicius anéas rodrigues null (vinicius.rodrigues@fosjc.unesp.br) on 2017-08-18T17:41:55Z No. of bitstreams: 1 tese Vinícius Anéas. Versão final.pdf: 3740548 bytes, checksum: b105ec4a9bf6381e20370d163a9e7d0c (MD5) / Approved for entry into archive by Luiz Galeffi (luizgaleffi@gmail.com) on 2017-08-23T19:31:12Z (GMT) No. of bitstreams: 1 rodrigues_va_dr_sjc.pdf: 3740548 bytes, checksum: b105ec4a9bf6381e20370d163a9e7d0c (MD5) / Made available in DSpace on 2017-08-23T19:31:12Z (GMT). No. of bitstreams: 1 rodrigues_va_dr_sjc.pdf: 3740548 bytes, checksum: b105ec4a9bf6381e20370d163a9e7d0c (MD5) Previous issue date: 2017-08-02 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo in vitro foi analisar a distribuição das microdeformações geradas ao redor de implantes de hexágono externo, sob a influência da utilização de intermediários do tipo mini pilares cônicos retos e angulados 17° e 30°, sob cargas axiais e não axiais, por meio da análise de elementos finitos e extensometria. Os modelos tridimensionais foram criados simulando três blocos de poliuretano, os quais receberam três implantes cada, um grupo perpendicular e outros dois com fixações inclinadas em 17° e 30°. Para o estudo também foram modelados os intermediários do tipo mini pilar cônico reto e angulados e uma supraestrutura metálica padronizada para ambos os grupos, os materiais foram considerados homogêneos, isotrópicos e lineares. Após a confecção, as geometrias foram exportadas em malhas para o software de análises (ANSYS 15.0, ANSYS Inc., Houston, USA), um carregamento axial de 30 kgf foi aplicado e os valores de tensão e as microdeformações foram analisados. Para análise in vitro, foram confeccionados blocos idênticos aos desenhados anteriormente. Foram colados sete extensômetros na superfície dos blocos, quatro tangenciando cada um dos implantes e três na transversal dos implantes. Coifas plásticas foram adaptadas a um enceramento padronizado e depois fundidas. A supraestrutura metálica foi parafusada com torque de 10 N.cm. Para aplicação de cargas foi utilizado um dispositivo de aplicação de cargas (DAC) com uma carga de 30 kgf. durante 10 segundos. Os dados obtidos foram submetidos aos testes ANOVA e Tukey (p< 0,05). Observou-se diferença estatística para os fatores “Angulação do implante” (P=0,000) e o fator “Ponto de aplicação de carga” (P=0,000). Os dados obtidos pela análise de elementos finitos foram apresentados como: resultados qualitativos de tensão que foram analisados seguindo o esquema de cores da escala e resultados de valores de deformação, apresentados em gráficos, onde se observou maior concentração de tensão nos implantes inclinados em 30° localizados nos pontos não axiais 3 e 5 mm, o mesmo ocorreu com os valores de deformação encontrados na superfície ao redor dos implantes. O estudo concluiu que os implantes inclinados apresentaram maiores valores de microdeformações ao redor dos implantes, sendo as aplicações de cargas não axiais nos pontos 3 e 5 mm responsáveis por produzirem aumento na magnitude. Apenas o grupo reto 0° apresentou resultados dentro do limite fisiológico em todas as configurações de aplicação de carga. / The objective of this in vitro study was to analyze microstrains distribuition generated around external hexagon implants, under the influence of intermediary prosthetic componentes as straight, 17° and 30° angled miniconical abutments, under axial and non-axial loads, by finite elements and strain-gauge analysis. The three-dimensional models were created simulating three polyurethane blocks, being installed three implants each, one perpendicular group and another two with inclined fixations at 17° and 30°. For the study were also created straight and angled miniconical abutments and a standardized metallic superstructure for both groups. The materials were considered symmetrical, isotropic and solid. After the preparation, the geometries were exported in mesh to the analysis software (ANSYS 15.0, ANSYS Inc., Houston, USA). An axial load of 30 kgf was applied and the values of main maximum stress and microstrains were analyzed. For in vitro analysis, blocks identical to those created previously were made, seven strain-gauges were placed on the surface of the block, four tangential to each of the implants and three transverse to the implants. Plastic copings were adapted to a wax pattern and then cast. The metallic superstructure was screwed with a torque of 10 N.cm. For load application, a load application device (DAC) with a load of 30 kgf was used, for 10 seconds. Data were submitted to ANOVA and Tukey tests (p <0.05). Statistical difference was observed for "Implant angulation" factors (P = 0.000) and "Load application point" factor (P = 0.000). The data obtained by the finite element analysis were presented as: qualitative results of stress that were analyzed following the color scheme of the scale and results of deformation values, presented in graphs, where it observed a higher concentration of tension in the inclined implants in 30° at the non-axial points 3 and 5 mm, the same occurred with the deformation values found on the surface around the implants. The study can conclude that the inclined implants had higher values of microdeformations around the implants, and the applications of non-axial loads at points 3 and 5 mm are responsible for producing an increase in magnitude. Only the 0° straight group presented results within the physiological limit in all load application configurations.
186

Incorporação do metacrilato 2-tert-butilaminoetil a uma resina acrílica para a base protética: caracterização química e efeito sobre a resistência flexural

Rodriguez, Larissa Santana [UNESP] 05 April 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:29:12Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-04-05Bitstream added on 2014-06-13T19:17:33Z : No. of bitstreams: 1 rodriguez_ls_me_arafo.pdf: 1313049 bytes, checksum: 4063f1e0e598d952104412578f2d3739 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / A fim de prevenir infecções bucais e consequentemente melhorar a qualidade de vida dos usuários de prótese, diversas tentativas de incorporar agentes antimicrobianos a resinas acrílicas tem sido relatadas na literatura. A incorporação do metacrilato 2-tert-butilaminoetil (TBAEMA) a uma resina acrílica para base protética seria uma alternativa plausível no intuito de se reduzir ou eliminar a colonização dessa superfície por microrganismos patogênicos, pois esta substância apresenta grupos amina em sua composição, o que poderia indicar uma possível atividade antimicrobiana da base protética. Objetivo: O objetivo deste trabalho foi investigar a interação química entre o TBAEMA e a resina acrílica bem como a presença de grupos amina na superfície da resina, e ainda avaliar a temperatura de transição vítrea e a resistência à flexão da resina após a incorporação de TBAEMA. Material e método: Os espécimes foram divididos em cinco grupos de acordo com as concentrações de TBAEMA incorporadas à resina Onda-Cryl: 0%, 1%, 2%, 3% e 4%. A superfície dos espécimes foi avaliada por meio de Espalhamento Superficial de Elétrons com Análise Química (XPS-ESCA) para detectar a presença de grupos amina, representado por índices de nitrogênio. As análises de Espectroscopia de Infravermelho por Transformada de Fourier (FTIR) e Calorimetria Diferencial de Varredura (DSC) foram utilizadas para avaliar o processo de polimerização da resina 17 acrílica na presença do TBAEMA e a influência da incorporação do TBAEMA na temperatura de transição vítrea (Tg) da resina, respectivamente. A resistência à flexão dos espécimes também foi avaliada e os resultados foram analisados por meio de análise de variância a um fator (ANOVA) seguido pelo teste de Tukey ( <0.05). Resultados: Foram observados diferentes índices de nitrogênio: 0,36%, 0,54%, 0,35% e 0,20% para... / With a purpose of to prevent oral infections and therefore improve the quality of life of dentures wearers, several attempts to incorporate antimicrobial agents into acrylic resins have been reported in the literature. The incorporation of 2-tert-butylaminoethyl methacrylate (TBAEMA) into denture base acrylic resin would be a plausible alternative in order to reduce or eliminate colonization of that surface by pathogenic microorganisms, on this account this substance has amine groups in their composition, which could indicate a possible antimicrobial activity of the denture base. Purpose: The purpose of this study was to investigate the chemical interaction between the TBAEMA and acrylic resin and the presence of amine groups in the resin surface, and assess the glass transition temperature and flexural strength of the resin after the incorporation TBAEMA. Material and Method: The specimens were divided in five groups according to the concentration of TBAEMA incorporated to Onda-Cryl: 0%, 1%, 2%, 3% and 4%. Specimens surfaces were evaluated by Electron Spectroscopy for Chemical Analysis (ESCA) to detect the presence of amino groups, represented by nitrogen ratios. Fourier Transform Infrared Spectroscopy (FTIR) and Differential Scanning Calorimetry (DSC) analysis were used to evaluate the polymerization process of acrylic resin in the presence of TBAEMA and the influence of the incorporation of TBAEMA on the glass transition temperature (Tg) of acrylic resin, respectively. Flexural strength of the... (Complete abstract click electronic access below)
187

Avaliação do comportamento de parafusos de retenção de próteses implanto suportadas: plataforma hexágono externo

Wingert, Augusto January 2015 (has links)
Made available in DSpace on 2015-06-18T02:05:59Z (GMT). No. of bitstreams: 1 000470532-Texto+Completo-0.pdf: 1614440 bytes, checksum: e43e90ac45fd2b22f0d595dd9c475e47 (MD5) Previous issue date: 2015 / This study aimed to evaluate "in vitro" possible changes on prosthetic retaining screws on implants with platform external hexagon, this because the loosening this component is very common in clinical dentistry practice. Were assessed screws of UCLA's pillars of titanium Neodent® brand and 3i BIOMET® and of titanium with surface treated with tungsten carbide Neodent® brand. Two techniques of utilization of the screws were compared, the technique I, recommended by the manufacturer with only the definitive torque, and the technique II, utilized in broad scale in Brazil where multiple torques are applied in the same screw simulating the clinical steps, up to definitive installation. The initial weight of all the screws (T0) was registered, in the screws of technique I, it was given definitive torque (32N. cm to Neodent® and 20N. cm to 3i BIOMET®) submitted to mechanical cycling and the final weight (TF) registered. In the screws of technique II have been applied opening and closing cycles, and their weights registered (T1, T2 and T3) before applying the definitive torque and mechanical cycling after the final weight has been registered (TF).The morphologies and the surface compositions of the screws were evaluated using SEM and EDS at each time. The results showed significant weight loss in the three screws groups, of technique I (p = 0. 005 for uncoated Neodent®, p = 0. 007 for coated Neodent® and p = 0. 001 to 3i BIOMET®) and on two the steps of the three groups of technique II (p <0. 001 for all groups), and comparing the final weight of the screws of the two techniques, the screws of the technique I, showed significantly higher values than the screws, of the technique II (p = 0. 007 for uncoated Neodent®, p = 0. 009 for coated Neodent® and p = 0. 001 to 3i BIOMET®), as well as SEM showed less permanent deformation for the technique I. EDS showed no major changes in the surface compositions. Therefore, the use of the definitive screw only at time of final torque can minimize problems regarding to the loosening the retaining screws of implant supported prostheses. / O presente estudo teve como objetivo avaliar “in vitro” possíveis alterações em parafusos de retenção de próteses sobre implantes com plataforma hexágono externo, isto porque o afrouxamento deste componente é muito frequente na prática clínica odontológica. Foram avaliados parafusos de pilares UCLA de titânio da marca Neodent® e 3i BIOMET® e de titânio com superfície tratada com carboneto de tungstênio da marca Neodent®. Duas técnicas de utilização dos parafusos foram comparadas, a técnica I, recomendada pelo fabricante com apenas o torque definitivo, e a técnica II, utilizada em grande escala no Brasil onde são aplicados múltiplos torques no mesmo parafuso, simulando as etapas clínicas até a instalação definitiva. Foi registrado o peso inicial de todos os parafusos (T0), nos parafusos da técnica I foi dado torque definitivo (32N. cm para Neodent® e 20N. cm para 3i BIOMET®), submetidos a ciclagem mecânica e registrado o peso final (TF).Nos parafusos da técnica II foram aplicados ciclos de abertura e fechamento e seus pesos registrados (T1, T2 e T3) antes da aplicação do torque definitivo e ciclagem mecânica, após o peso final foi registrado (TF). As morfologias e as composições de superfície dos parafusos foram avaliadas através de MEV e EDS em cada tempo. Os resultados evidenciaram perda significativa de peso nos três grupos de parafusos da técnica I (p=0,005 para Neodent® sem revestimento, p=0,007 para Neodent® com revestimento e p=0,001 para 3i BIOMET®) e em duas das etapas dos três grupos da técnica II (p<0,001 para todos os grupos), sendo que comparando o peso final dos parafusos das duas técnicas, os parafusos da técnica I apresentaram valores significativamente maiores que os parafusos da técnica II (p=0,007 para Neodent® sem revestimento, p=0,009 para Neodent® com revestimento e p=0,001 para 3i BIOMET®), assim como a MEV evidenciou menor deformação permanente para a técnica I. EDS não apresentou grandes alterações nas composições de superfície. Portanto, a utilização do parafuso definitivo apenas no momento do torque final pode minimizar problemas com relação ao afrouxamento de parafusos de retenção de próteses implanto suportadas.
188

Avaliação do comportamento de parafusos de retenção de próteses implanto suportadas: conexão hexágono interno

Souza, Elbio Costa January 2015 (has links)
Made available in DSpace on 2015-07-31T02:03:30Z (GMT). No. of bitstreams: 1 000472789-Texto+Completo-0.pdf: 2619919 bytes, checksum: ed658917522947aaf046eb032864fcc4 (MD5) Previous issue date: 2015 / This study aimed to evaluate "in vitro" possible changes on prosthetic retaining screws on implants with platform external hexagon, this because the loosening this component is very common in clinical dentistry practice. Were assessed screws of UCLA's pillars of titanium Neodent® brand and 3i BIOMET® and of titanium with surface treated with tungsten carbide Neodent® brand. Two techniques of utilization of the screws were compared, the technique I, recommended by the manufacturer with only the definitive torque, and the technique II, utilized in broad scale in Brazil where multiple torques are applied in the same screw simulating the clinical steps, up to definitive installation. The initial weight of all the screws (T0) was registered, in the screws of technique I, it was given definitive torque (32N. cm to Neodent® and 20N. cm to 3i BIOMET®) submitted to mechanical cycling and the final weight (TF) registered. In the screws of technique II have been applied opening and closing cycles, and their weights registered (T1, T2 and T3) before applying the definitive torque and mechanical cycling after the final weight has been registered (TF). The morphologies and the surface compositions of the screws were evaluated using SEM and EDS at each time. The results showed significant weight loss in the three screws groups, of technique I (p< 0. 005 for uncoated Neodent®, p = 0. 001 for coated Neodent® and p < 0. 001 to 3i BIOMET®) and on one step of the uncoated Neodent® group and two steps of the other two groups of technique II (p <0. 001 for all groups), and comparing the final weight of the screws of the two techniques, only the uncoated Neodent® screws of the technique I, showed significantly higher values than the screws, of the technique II (p = 0. 021 for uncoated Neodent®, p = 0. 089 for coated Neodent® and p = 0. 095 to 3i BIOMET®), as well as SEM showed less permanent deformation for the technique I of these screws. EDS showed no major changes in the surface compositions. Therefore, the use of the definitive screw only at time of final torque would not necessarily minimize problems regarding to the loosening the retaining screws of implant supported prostheses. / O presente estudo teve como objetivo avaliar “in vitro” possíveis alterações em parafusos de retenção de próteses sobre implantes com plataforma hexágono interno, pois o afrouxamento deste componente é muito frequente na prática clínica odontológica. Foram avaliados parafusos de pilares UCLA de titânio da marca Neodent® e 3i BIOMET® e de titânio com superfície tratada com carboneto de tungstênio da marca Neodent®. Duas técnicas de utilização dos parafusos foram comparadas, a técnica I, recomendada pelo fabricante com apenas o torque definitivo, e a técnica II, procedimento que é comumente realizado pelos profissionais no Brasil, onde são aplicados múltiplos torques no mesmo parafuso, simulando as etapas clínicas até a instalação definitiva. Foi registrado o peso inicial de todos os parafusos (T0), nos parafusos da técnica I foi dado torque definitivo (32N. cm para Neodent® e 20N. cm para 3i BIOMET®), submetidos a ciclagem mecânica e registrado o peso final (TF). Nos parafusos da técnica II foram aplicados ciclos de abertura e fechamento e seus pesos registrados (T1, T2 e T3) antes da aplicação do torque definitivo e ciclagem mecânica, após o peso final foi registrado (TF). As morfologias e as composições de superfície dos parafusos foram avaliadas através de MEV e EDS em cada tempo. Os resultados evidenciaram perda significativa de peso nos três grupos de parafusos da técnica I (p<0,001 para Neodent® sem revestimento, p=0,001 para Neodent® com revestimento e p<0,001 para 3i BIOMET®), e em uma das etapas do grupo Neodent sem cobertura e duas etapas dos outros dois grupos da técnica II (p<0,001 para todos os grupos), sendo que comparando o peso final dos parafusos das duas técnicas, apenas os parafusos Neodent® sem revestimento da técnica I apresentaram valores significativamente maiores que os parafusos da técnica II, (p=0,021 para Neodent® sem revestimento, p=0,089 para Neodent® com revestimento e p=0,095 para 3i BIOMET®), do mesmo modo a MEV evidenciou menor deformação permanente para a técnica I desses parafusos. EDS não apresentou grandes alterações nas composições de superfície. Portanto, a utilização do parafuso definitivo apenas no momento do torque final não minimizará necessariamente problemas com relação ao afrouxamento de parafusos de retenção de próteses implanto suportadas.
189

Influência da normalização dos níveis de cinza em tomografias computadorizadas Cone Beam e multislice na avaliação da qualidade óssea

Schneider, Danilo Renato January 2014 (has links)
Made available in DSpace on 2015-09-05T02:05:04Z (GMT). No. of bitstreams: 1 000474617-Texto+Completo-0.pdf: 1140625 bytes, checksum: 1e763d7b5cf7e0a7ceeb1f2842c8c315 (MD5) Previous issue date: 2014 / This paper aims to investigate the influence of normalization in cone beam computed tomography (CBCT) and multislice computed tomography (MSCT) grey level to assess bone quality of recipient sites for dental implants. DICOM (Digital Imaging and Communications in Medicine) images from 37 bone sites (18 patients) were analyzed. CBCT was performed with 5 different CBCT devices and MSCT in a single multislice CT scanner. Measurements of mean grey level were performed in two regions of interest; ROI1 - alveolar bone (cortical and trabecular) and ROI2 - cancellous bone separately with 3 tested forms: no normalization (RAW), normalization of the whole image (ALL) and normalization of the region of interest only (ROI). Descriptive analysis with coefficient of variation (CV) and one-way ANOVA followed by Tukey was performed. For MSCT, ROI1 mean grey level slightly increased from 121. 9+-17. 13 (RAW) to 125. 0+-15. 74 (ALL) (p>0. 05) and reduced to 104. 8+-15. 20 (ROI) (p<0. 0001). CV varied from 14. 05%, to 12. 59% and 14. 50%, respectively. ROI2 increased from 95. 11+-13. 96 (RAW) to 99. 40+-13. 62 (ALL) and 102. 5+-17. 86 (ROI) (p=0. 0678). CV was 14. 67% to 13. 71% and 17. 43%, respectively. In CBCT group, ROI1 meaningfully raise from 91. 73+-32. 17 (RAW) to 135. 2+-36. 06 (ALL) and 118. 7+-18. 65 (ROI) (p<0. 0001), with CV decreasing from 35. 06% to 26. 68% and 15. 71%, respectively. ROI2 was 81. 23+-34. 36, 115. 3+-28. 53 and 109. 4+-17. 47, respectively (p=0. 0002), with a CV reducing from 42. 30% (RAW) to 24. 74% (ALL) and 15. 97% (ROI). Therefore, the use of intensity normalization of CBCT and MSCT examinations was demonstrated on reducing discrepancies between different scanners and inter-exams variability in bone quality assessment for dental implants. / Este trabalho objetiva investigar a influência da normalização dos níveis de cinza em tomografias cone beam (CBCT) e multislice (MSCT). Imagens DICOM (Digital Imaging and Communications in Medicine) de 37 sítios ósseos (18 pacientes) foram analisadas. As tomografias CBCT foram realizadas em 5 diferentes aparelhos e as tomografias MSCT foram obtidas em um único tomógrafo. As medições dos níveis de cinza foram feitas em duas regiões de interesse; ROI1 - osso alveolar (cortical e medular) e ROI2 - osso medular separadamente, de 3 formas distintas: sem normalização (RAW), normalização de toda a imagem (ALL) e normalização da região de interesse apenas (ROI). Análise descritiva com coeficiente de variação (CV) e teste ANOVA seguido de Tukey foi realizado. Para as MSCT, a média dos níveis de cinza da ROI1 aumentaram levemente de 121,9+-17,13 (RAW) para 125,0+-15,74 (ALL) (p>0,05) e reduziram para 104,8+-15,20 (ROI) (p<0,0001). O CV variou de 14,05%, para 12,59% and 14,50%, respectivamente. Na ROI2 a média aumentou de 95,11+-13,96 (RAW) para 99,40+-13,62 (ALL) e 102,5+-17,86 (ROI) (p=0,0678). O CV foi de 14,67% para 13,71% e 17,43%, respectivamente. No grupo CBCT, a média de ROI1 aumentou significativamente de 91,73+-32,17 (RAW) para 135,2+-36,06 (ALL) e 118,7+-18,65 (ROI) (p<0,0001), com o CV diminuindo de 35,06% para 26,68% e 15,71%, respectivamente. A média da ROI2 foi 81,23+-34,36, 115,3+-28,53 and 109,4+-17,47, respectivamente (p=0,0002), com um CV reduzindo de 42,30% (RAW) para 24,74% (ALL) e 15,97% (ROI). Desta forma, foi demonstrada a redução das discrepâncias entre diferentes aparelhos e da variabilidade entre exames com a utilização da normalização de intensidade de exames CBCT e MSCT na avaliação da qualidade óssea para implantes dentais.
190

Construção de um biomodelo com interposição de placa oclusal para análise de tensões nos discos articulares da ATM pelo método dos elementos finitos

Silva, Carlos Augusto Gomes da January 2016 (has links)
Made available in DSpace on 2016-05-07T12:04:33Z (GMT). No. of bitstreams: 1 000478489-Texto+Parcial-0.pdf: 134804 bytes, checksum: 6d941459abeadf56a9fb5b1afbfe9927 (MD5) Previous issue date: 2016 / The aim of this study was to investigate the possibility of creating a three-dimensional model of the masticatory system of a patient for analysis in MEF. Also, to configure the parameters for the attainment of a clenching test with variations in intensities bite force with the interposition of two occlusal splints of different materials. Using the computed tomography (CT) and magnetic resonance imaging (MRI) of a patient, were built, through the process of reverse engineering, seven pieces to compose a biomodel. Four software was used throughout the process to achieve the desired result. Also, from this model was created finite element mesh of components and defined the boundary conditions. An occlusal splint was created and its physical and mechanical properties were switched to simulate the behavior of two different plates: a rigid and resilient. The model received force vectors that simulate the action of four pairs of muscles: temporal, masseter, medial pterygoid and lateral; and was assigned to these three distinct forces for each test: 25oN, 50oN and 75oN. According to what was found in this study it can be concluded that the construction of a biomodel from CT and MR images are completely feasible. In addition, the methodology used to obtain the models and the settings configured for the tests in MEF resulted in a good approach to clinical reality along the lines of current research. / O objetivo do presente estudo foi verificar a possibilidade da criação de um modelo tridimensional do sistema mastigatório de um paciente para análise em MEF. E também, configurar os parâmetros para a realização de um teste de apertamento dentário com variações nas intensidades de força de mordida com a interposição de duas placas oclusais de diferentes materiais. A partir dos exames de tomografia computadorizada (TC) e ressonância magnética (RM) de um paciente foram construídos, por meio de engenharia reversa, sete peças para compor um biomodelo. Quatro softwares foram usados em todo o processo até atingir o resultado desejado. Ainda, a partir deste modelo foi criada a malha de elementos finitos dos componentes e definidas as condições de contorno. Uma placa oclusal foi criada e suas propriedades físicas e mecânicas foram alternadas para simular o comportamento de duas placas distintas: uma rígida e uma resiliente. O modelo recebeu vetores de força que simularam a ação de quatro pares de músculos: temporal, masséter, pterigoideo medial e lateral; e foi atribuído a estes, três forças distintas para cada teste: 25ON, 50oN e 75oN. De acordo com o que foi apurado neste estudo é possível concluir que a construção de um biomodelo a partir de imagens de TC e RM e plenamente viável. Além disso, a metodologia adotada para obtenção dos modelos e as configurações definidas para os testes em MEF resultaram em uma boa aproximação a realidade clinica seguindo a linha das pesquisas vigentes.

Page generated in 0.0366 seconds