• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1509
  • 69
  • 69
  • 69
  • 69
  • 49
  • 17
  • 11
  • 11
  • 10
  • 7
  • 5
  • 3
  • 2
  • 2
  • Tagged with
  • 1536
  • 774
  • 497
  • 457
  • 365
  • 347
  • 292
  • 240
  • 219
  • 198
  • 187
  • 185
  • 175
  • 168
  • 141
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
191

Efeito do envelhecimento In Vitro na transformação de fase cristalina da Y-TZP : análise topográfica, mecânica e cristalográfica /

Arata, Anelyse. January 2012 (has links)
Orientador: Rubens Nisie Tango / Coorientador: Guilherme de Siqueira Ferreira Anzaloni Saavedra / Banca: Rubens Nisie Tango / Banca: João Paulo Barros Machado / Banca: Tarcísio José de Arruda Paes Junior / Resumo: A literatura mostra escassez de informações sobre o envelhecimento de cerâmicas Y-TZP de uso odontológico. O objetivo deste estudo foi o de avaliar o efeito do envelhecimento in vitro inicial em autoclave e avaliar a curva cinética de transformação de fase através do envelhecimento em reator hidrotérmico pressurizado em zircônia odontológica (Y-TZP). Especificamente: a - identificar o início da degradação, b - avaliar a resistência mecânica após envelhecimento inicial em autoclave, ccomparar diferentes métodos de leitura quanto à transformação de fase e análise topográfica, d - determinar a cinética de cristalização isotérmica por meio do envelhecimento em reator, e -comparar os métodos de quantificação a partir da equação de Garvie e Nicholson e o método de Rietveld. Discos de zircônia (12mm Ø x 1,2mm em espessura) foram divididos em grupos: A) envelhecido em autoclave (n=10); B) envelhecido em reator (n=4). O grupo A foi submetido ao envelhecimento em autoclave (134 oC, 2 bar), em tempos de 6, 15, 30, 42, 60, 90, 144, 198, 240, 300 e 360 minutos. O grupo B foi submetido ao envelhecimento em reator (130 oC, 2 bar), em tempos de 6, 8, 10, 12, 14, 20, 30, 40, 48, 60, 84, 108 e 138 horas. A caracterização superficial e cristalográfica foi realizada antes e depois em microscopia de força atômica (MFA), Perfilometria óptica, Difração de Raios-X e, também foram realizadas análises em microscopia eletrônica de varredura (MEV) e Raman. O grupo envelhecido em autoclave foi submetido ao teste de flexão biaxial. Os valores de Ra (nm) obtidos em Perfilometria Óptica, os valores de resistência (MPa) e os valores de transformação de fase cristalina t-m (%) foram submetidos à análise de variância de 1 fator e ao teste de Tukey... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The literature shows a lack of information about Y-TZP aging of dental ceramics. The aim of this study was to evaluate the initial in vitro aging effect and evaluate the kinetic curve of phase transformation through the pressurized hydrothermal reactor of dental zirconium. Specifically: a- the identification of the beginning of degradation; b- evaluation of the mechanical resistance after steam aging; c- compare different methods of phase transformation and topographic analysis, d- determine the kinetic of crystallization through the reactor; e- compare the phase quantification methods between the Garvie and Nicholson equation and Rietveld Method. Discs of zirconium (12mm Ø x 1,2mm thickness) were divided in groups: A) steam aged (n=10); B) Hydrothermal reactor aged (n=4). The group A was submitted to water steam aging (134 oC, 2 bar) for 6, 15, 30, 42, 60, 90, 144, 198, 240, 300 and 360 minutes. The group B was submitted to reactor aging (130 oC, 2 bars), for 6; 8; 10; 12; 14; 20; 30; 40; 48; 60; 84; 104 and 138 hours. The surface and crystallographic characterization before and after aging were made using atomic force microscopy (AFM), Optical Profilometry, X-ray diffraction (DRX), scanning electron microscopy (SEM) and Raman spectroscopy. The steam aged group was submitted to biaxial flexure test. The values of Ra (nm) obtained by optical profilometry and the crystalline phase transformation values t-m (%) were submitted to One Way ANOVA and Tukey test(α=0,05). A gradual increase was observed at the monoclinic phase concentration as the time increased and in the same way the roughness values increased. The resistance values demonstrated a tendency to decrease with the increase of aging time. The group aged by the reactor presented the increase of monoclinical phase reaching 60% of saturation through... (Complete abstract click electronic access below) / Mestre
192

Simulação numérica através do método dos elementos finitos e comparação experimental para obtenção de tensões e deformações específicas em fêmur com prótese total de quadril /

Queiroz, Liana Paula. January 2014 (has links)
Orientador: Mauro Pedro Peres / Coorientador: Marcelino Pereira do Nascimento / Banca: Marcelo Sampaio Martins / Banca: Renata Aparecida Ribeiro Custódio / Resumo: As tensões atuantes no fêmur com prótese total de quadril devem ser compreendidas para a melhoria nos processos de fabricação, cirúrgicos e reabilitação de um paciente implantado refletindo em sua qualidade de vida após a cirurgia. Essa pesquisa tem por finalidade a modelagem e a simulação numérica das tensões e deformações específicas atuantes num conjunto fêmur-prótese a fim de avaliar o comportamento estrutural do fêmur e verificar as maiores tensões em sua diáfise medial após uma Artroplastia Total de Quadril (ATQ), através do Método dos Elementos Finitos (MEF) e a comparação dos dados obtidos na simulação com dados obtidos experimentalmente. A simulação foi realizada pelo software ANSYS® de acordo com as normas da ABNT para ensaios em próteses de quadril. Um conjunto osso-prótese foi submetido a um carregamento de até 1000 N na direção perpendicular ao eixo horizontal, na linha de inserção da prótese. Foram realizadas simulações considerando o conjunto com propriedades biológicas e ortotrópicas, sintéticas e isotrópicas, uma simulação considerando um fêmur intacto e isotrópico para comparação e um ensaio laboratorial em um conjunto formado por um fêmur sintético e uma prótese de liga de titânio, nas mesmas condições das simulações computacionais com o objetivo de comparar as deformações. Concluiu-se que a partir das condições impostas neste trabalho, as tensões em um conjunto osso-prótese são muito próximas das tensões em um fêmur intacto, possuindo as mesmas tendências no que se diz respeito às fraturas por carregamento / Abstract: The stresses acting on the femur with total hip replacement should be understood to improvement in manufacturing, surgical and rehabilitation of a patient implanted processes reflecting on their quality of life after surgery. The research aims to model simulate computationally the forces acting on a femoral prosthesis set, to evaluate the structural behavior of the femur and checker the biggest stresses in your diaphysis after Total Hip Arthroplasty using the Finite Element Method (FEM). ANSYS software was used for the simulation. The conditions imposed in accordance with ABNT for hip prostheses trials were used in the process. A bone-prosthesis set was subjected to a load up to 1000 N in the perpendicular direction to the horizontal axis on the line of insertion of the prosthesis. Simulations were performed considering the set biological, orthotropic, synthetic and isotropic properties. Three computational simulations under the same conditions were performed in order to compare the deformations. A simulation considering an intact isotropic femur with the and a laboratory test of a set consisting of a synthetic femur and a titanium alloy femoral prosthesis. Based on the conditions imposed in this study we conclude that the stresses in a bone prosthesis set are very similar to a tension in an intact femur, having the same trends with respect to the loading fractures / Mestre
193

Artroplastia total híbrida nacional em cães Portadores de displasia coxofemoral /

Rossetto, Victor José Vieira. January 2015 (has links)
Orientador: Claúdia Valéria Seullner Brandão / Banca: Gilberto José Cação Pereira / Banca: Bruno Watanabe Minto / Banca: Luiz Carlos Vulcano / Banca: Priscilla Macedo de Souza / Resumo: A artroplastia total coxofemoral de uma maneira geral é a técnica cirúrgica mais indicada para o tratamento da displasia coxofemoral grave em humanos e cães, e consiste na substituição das extremidades ósseas que compõem a articulação por componentes protéticos. O objetivo do presente trabalho foi avaliar a artroplastia total modular híbrida, desenvolvida no Brasil, como opção de tratamento para casos de displasia coxofemoral moderada ou grave até 180 dias de pós-operatório, bem como a frequência das suas potenciais complicações. Para isso, foram utilizados 10 animais da espécie canina, de raças variadas, esqueleticamente maduros, machos e fêmeas, portadores de displasia coxofemoral moderada ou grave, e submetidos ao procedimento de artroplastia total utilizando-se componente femoral cimentado de cabeça intercambiável e componente acetabular não cimentado. Os cães foram avaliados por meio de exames ortopédico e radiográfico no período pósoperatório imediato, e aos 30, 60, 120 e 180 dias após a cirurgia; e exame tomográfico no período pós-operatório imediato, e aos 120 e 180 dias de pós-operatório. Com relação à avaliação da função locomotora e intensidade de dor, o procedimento cirúrgico conferiu melhora em, respectivamente, 60% e 90% dos animais avaliados. Dentre os animais selecionados, seis (60%) apresentaram complicações pós-operatórias. As principais complicações verificadas incluíram infecção, soltura asséptica do componente acetabular, luxação do componente femoral em relação ao acetabular e fratura femoral periprostética. A seleção dos proprietários e animais deve ser rigorosa na tentativa de reduzir sobremaneira as complicações verificadas / Abstract: Total hip arthroplasty is generally the most commonly performed surgical technique for severe hip dysplasia treatment in humans and dogs, and consists of the replacement of the hip joint by prosthetic components. The aim of this study was to evaluate the hybrid total arthroplasty, developed in Brazil, as a treatment option for dogs with moderate or severe hip dysplasia up to 180 days after surgery by clinical, radiographical and tomographical evaluations, and the frequency of the potential complications. For this, we utilized 10 dogs of variable breeds, skeletally mature, male and female, with moderate or severe hip dysplasia and submitted to total hip arthroplasty using cemented femoral component of exchangeable head and cementless acetabular component. The dogs were evaluated by orthopaedic and radiographical examinations at imediate postoperative period, and at 30, 60, 120 and 180 days after surgery; and by CT scan at imediate postoperative period, and at 120 and 180 days after surgery. Surgery conferred improvement of the locomotor function and intensity of pain in, respectively, 60% and 90% of the evaluated animals. Among the selected animals, six (60%) had postoperative complications. Major complications included infection, aseptic loosening of the femoral component, femoral component dislocation and femoral periprosthetic fracture. The selection of owners and animals must be rigorous in trying to greatly reduce the complications observed / Doutor
194

Efeito de diferentes tratamentos térmicos sobre a resistência à abrasão por escovação de resinas utilizadas para reembasamento de próteses removíveis /

Mendonça, Márcio José. January 2003 (has links)
Orientador: Ana Lucia Machado / Banca: Ligia Antunes Pereira Pinelli / Banca: Alma Blásida Concepción Elizaur Benitez Catirse / Resumo: Este estudo avaliou o efeito de 2 tratamentos térmicos na abrasão por escovação das resinas para reembasamento Duraliner II (D) , Kooliner (K) e Tokuso Rebase (T) e da resina termopolimerizável para base de prótese Lucitone 550 (L). As amostras foram confeccionadas utilizando-se uma matriz de aço (40x10x2mm). Após a polimerização, 36 amostras de cada resina foram submetidas a um dos tratamentos térmicos: irradiação por microondas (D -650W/4min; K - 550W/5min, T - 550w/ 4 min. e L - 500W/3min) e imersão em água a 55°C por 10 minutos para as resinas D, K e T e imersão em água a 55°C por 60 minutos para a resina L. As amostras restantes (n=18) foram utilizadas como controle. As amostras foram pesadas, sucessivamente, até obtenção de massa constante. A seguir, foram posicionadas em uma máquina de escovação, imersas em solução de 1:1 dentifrício/água deionizada, e os ensaios foram realizados aplicando-se 200 g sobre cada escova. Após 20.000 ciclos, as amostras foram novamente recondicionadas até massa constante e a abrasão foi calculada (mg). A rugosidade superficial (Ra) também foi avaliada, por meio de rugosímetro, antes e após os ensaios. Os valores obtidos foram analisados por meio de análise de variância, seguida pelo teste de Tukey, e por meio do teste não paramétrico de Kruskal-Wallis, em nível de significância de 5%. Os resultados de perda de massa indicaram que a resistência à abrasão dos materiais D, K e L não foi influenciada, significativamente (p>0,05), pelos tratamentos (GII - K - 1,5 mg; D - 1,1?mg; L - 1,6?mg; GIII - K - 1,4?mg; D - 1,7?mg; L - 2,1mg), quando comparados com o grupo controle (GI - K - 2,1 mg; D - 1,2 mg; L - 2,7?mg). Entretanto, a imersão em água aquecida (GII - 1,9 mg) e a irradiação com microondas (GIII - 1,8 mg) afetaram negativamente (p<0,05) a resistência à abrasão do material T (GI - controle - 5 mg)...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study evaluated the effect of two heat-treatments on the toothbrushing abrasion of the hard chair-side reline resins Duraliner II (D) and Kooliner (K), Tokuso Rebase (T) and the heat-polymerized denture base resin Lucitone 550 (L). Specimens were made by using a stainless steel mold (40x10x2mm). After processing, 36 specimens of each material were submitted to one of the following heat-treatments: microwave irradiation (D-650W/4min; K-550W/5min, T - 550w/4 min. e L 500W/3min) and immersion in water at 55o C for 10 min for D, K and T and immersion in water at 55o C for 60 min for L. The remaining specimens (n=18) served as control. The specimens were then submitted to successive weighings until constant mass. Tests were performed in a toothbrush abrasion machine using 20.000 strokes of brushing at a weight of 200 g. During the tests the specimens remained immersed in a slurry (1:1 dentifrice/deionised water). After testing, specimens were again reconditioned to constant weight and the mass loss was calculated (mg). Surface roughness (Ra) of the specimens was also evaluated with a profilometer, before and after being submitted to the tests. The results were analyzed by one-way analysis of variance (ANOVA) followed by Tukey's test, and Kruskal-Wallis non-parametric test. The analyses were conducted at 95% confidence level. The mass loss data indicated that the wear of material K, D and L was not significantly (p>0,05) affected by the heat-treatments (GII - K - 15 mg; D - 11 mg; L - 16 mg; GIII - K - 14 mg; D - 17 mg; L - 21 mg), compared with the control group (GI - K - 21 mg; D - 12 mg; L - 27 mg). However, immersion in hot water (GII - 19 mg) and microwave irradiation (GIII - 18 mg) resulted in higher weight loss (p<0 0,05) for material T compared with control group (GI - 5 mg). The material L ...(Complete abstract, click electronic access below) / Mestre
195

Discrepâncias de assentamento ocorrido em coroas totais metálicas, com e sem alívio interno, variando-se os términos cervicais e os agentes cimentantes /

Figueiredo, Aldari Raimundo January 1997 (has links)
Orientador: Marco Antonio Bottino / Banca: Pedro Tortamano Neto / Banca: Orlando Magalhães Filho / Banca: José Eduardo Junho de Araujo / Banca: Ruy Fonseca Brunetti / Resumo: Foi feita uma análise das discrepâncias de assentamento ocorridas na cimentação de coroas totais metálicas aliviadas ou não, internamente, sobre preparos com término cervical em chanfro; linha zero ou lâmina de faca; plano inclinado em 135°; ombro reto ou degrau em 90° e ombro reto ou degrau em 90°, associado a um bisel em 45°. Empregaram-se quatro tipos de cimentos, sendo três classificados como temporários à base de óxido de zinco e eugenol (Temp Bond e Provy) e outro sem eugenol (Temp Bond NE); e um quarto indicado para cimentações definitivas, cimento de Fosfato de Zinco. Idealizou-se modelos-padrão usinados em aço inoxidável, com características de um preparo para coroa total metálica em um primeiro molar inferior variando-se os términos cervicais conforme estabelecido. Foram obtidas cápsulas metálicas usinadas em aço inoxidável e perfeitamente adaptadas aos modelos-padrão com os términos cervicais correspondentes, nas condições de estarem aliviadas internamente ou não. Empregou-se uma técnica de cimentação padronizada para assentamento destas cápsulas metálicas nos modelos-padrão respectivos. Através de metodologia original promoveu-se a mensuração da discrepância de assentamento nos corpos-de-prova, com o aparelho Metroscópio Horizontal. Concluiu-se que: a) o alívio executado nas superfícies internas das coroas diminui de forma estatisticamente significante a discrepância marginal após a cimentação, independentemente do tipo de cimento empregado e da forma do término cervical adotada; b) o término cervical do preparo no modelo-padrão tipo Lâmina de Faca foi o que apresentou menor discrepância, independente do cimento empregado, seguido pelo Plano Inclinado, Chanfro, Ombro Biselado e Ombro Reto; c) os términos cervicais em Chanfro, Plano Inclinado e Lâmina de Faca, quando analisadas as amostras dos corpos-de-prova com alívio, .... / Abstract: Seating discrepancies during cementation of complete metal crowns internally relieved or not with various finishing lines and cementing agents. This study evaluated the discrepancies during cementation of complete metal crowns either relieved or not on preparation with various margin designs: chamfer, knife edge, 135 degree shoulder, 90 degree shoulder, 90 degree shoulder with 45 degree bevel. Four types of cements, three temporary and one definitive were used: 1- zinc oxide and eugenol temporary cement (Temp Bond); 2- zinc oxide and eugenol temporary cement (Provy); 3- no eugenol temporary cement (Temp Bond NE) and 4- zinc phosphate cement (S.S.White). Machined stainless dies were fabricated to resemble complete crown preparations for a lower first molar with various finishing lines. Machined stainless steel copings, either internally relieved or not were also fabricated to fit the metal dies. A controlled technique was developed to assess seating discrepancies under the horizontal metroscope. Results showed: a) the internally relieved crowns showed after cementation statistically significant reduction of marginal discrepancies regardless of cement type or margin desing; b) knife edge finishing lines showed least dicrepancies regardless of cement type followed by the 135 degree shoulder, chamfer, bevelled 90 degree shoulder and 90 degree shoulder; c) internally relieved copings with chamfer, 135 degree shoulder and knife edge finishing lines showed no statiscally significant marginal discrepancies. This indicates that any of them yields favorable results; d) regarding cements, the least marginal discrepancies were found with Temp Bond NE followed by Temp Bond, Provy and finally by the Zinc Phosphate Cement (S.S.White) / Doutor
196

Estudo clínico comparativo da manutenção do aprofundamento de sulco nas vestibuloplastias mandibulares, através das técnicas de tuneilização submucosa e epitelização secundária /

Marques, Eduvaldo Silvino de Brito. January 1993 (has links)
Orientador: Antenor Araújo / Banca: Mario Francisco Real Gabrielli / Banca: Franklin Edgard de Moura Campos / Resumo: Inúmeras tem sido as tentativas dos mais variados cirurgiões bucais, em realizar técnicas cirúrgicas com o intuito de melhorar os rebordos alveolares para a colocacão de próteses totais. Basicamente as técnicas empregadas para esta finalidade estão divididas em quatro grupos, que são: tuneilização submucosa; epitelização secundária; enxerto de tecidos moles e transposição de retalhos. Os pacientes foram selecionados na clínica de Cirurgia e Traumatologia Buco-Maxilo-Facial, da Faculdade de Odontologia de São José dos Campos em número de vinte, dentre aqueles que necessitavam de próteses totais e que tinham dificuldades na utilização das mesmas no que se refere a estabilidade e retenção. Foram dividas em dois grupos, e submetidos respectivamente as técnicas cirúrgicas de tuneilização submucosa com uso de goteiras, e epitelização secundária através da técnica de Clark, e, avaliados no que concerne a estabilidade após doze meses. Os resultados foram obtidos através de exames clínicos e radiográficos antes e após a realização das cirurgias, sendo que de um modo geral, são próximos aos relatados na literatura, atingindo-se critérios satisfatórios de funcionabilidade / Abstract: For some time, oral surgeons have tried several surgical procedures to improve the alveolar ridge for prosthetic appliance construction. The techniques used for this purpose are divided into four groups: submucosal vestibuloplasty; secondary epithelization; soft tissue grafting and transpositional flaps. Twenty patients who had problems to wear dentures due to unsatisfactory retention and stability were selected at the Oral and MaxilloFacial Surgery and Traumatology Clinic of Dental School of São José dos Campos. They were divided in two groups and operated by submucosal vestibuloplasty using stents and secondary epithelization vestibuloplasty by Clark's technique and were evaluated twelve months after operations in relationship of the sulcus depth. The results were obtained by clinical and radiological examination before and after surgery, and they are similar to those found in the literature reaching satisfactory functional judgement / Mestre
197

Citotoxidade de cimentos resinosos sobre célular obtidas da polpa de dentes humanos (HDPCs) e odontoblastóides (MDPC-23) /

Pontes, Elaine Cristina Voltolini. January 2014 (has links)
Orientador: Carlos Alberto de Souza Costa / Banca: Gelson Luis Adabo / Banca: Adriano Lima / Resumo: O objetivo deste estudo foi avaliar a citotoxicidade de cimentos resinosos quando aplicados sobre cultura de células odontoblastóides (MDPC-23) e pulpares humanas (HDPC). Os seguintes grupos foram formados: G1 - controle (sem tratamento); G2 - Rely X Luting 2; G3 - Rely X U200; G4 - Rely X ARC. Corpos de prova padronizados, preparados com os cimentos, foram imersos em 1 mL de meio de cultura (DMEM) por 24hs para obtenção dos extratos (DMEM + componentes liberados dos cimentos). Após aplicar os extratos sobre as células por 24hs, a viabilidade (MTT assay) e tipo de morte celular (Anexina/PI), bem como a morfologia das células (MEV) foram avaliados. Os dados obtidos foram submetidos à análise estatística de Kruskal-Wallis complementada por Mann-Whitney (α=5%). A análise química dos extratos foi realizada por cromatografia liquida de alta performance (HPLC). Nos grupos G2, G3 e G4, observou-se redução de 95,8%, 31,5% e 22,7% na viabilidade das células MDPC-23, respectivamente. Redução de 89,4% para G2 e aumento em 11,3% e 29% para G3 e G4, respectivamente, foram observados para as HDPCs. Para as células MDPC-23, redução significativa de viabilidade ocorreu em G2 e G3 quando comparado à G1; todavia, para as HDPCs esta redução foi observada apenas em G2 (p<0,05). Para ambas as culturas usadas no estudo, ocorreu 100% de morte celular por necrose apenas em G2, onde o pH do extrato era ácido. Em G3, onde uma pequena quantidade de TEGDMA foi detectado no extrato, houve reduzida morte celular por necrose e discreta alteração morfológica nas células. Todavia, nenhum dano celular ocorreu em G4. De maneira geral, a células MDPC-23 são mais sensíveis do que as HDPCs. Concluiu-se que apenas o cimento Rely X Luting 2 causou intenso efeito citotóxico para ambas culturas de células pulpares usadas neste estudo. Rely X U200 apresentou discreta citotoxicidade, enquanto o cimento Rely X ARC não foi tóxico para as células pulpares... / Abstract: The aim of this study was to evaluate the cytotoxicity of luting cements on cultured MDPC-23 odontoblast-like cells and human dental pulp cells (HDPCs). The following groups were formed: G1 - control (no treatment), G2 - Rely X Luting 2, G3 - Rely X U200; G4 - Rely X ARC. Standard round specimens prepared with resin cements were immersed in 1 ml of culture medium (DMEM) for 24 hours to obtain the extract (DMEM + components released from the cement). After applying the extracts to the cells for 24 hours, the viability (MTT assay) and type of cell death (Annexin/PI) as well as cell morphology (SEM) were evaluated. The data obtained was submitted to Kruskal-Wallis statistical analysis complemented by Mann-Whitney test (α=5%). The chemical analysis of the extracts was performed by high performance liquid chromatography (HPLC). In G2, G3 and G4, there was a reduction of 95.8 %, 31.5 % and 22.7 % in the MDPC-23 cells viability, respectively. A reduction of 89.4 % for G2, as well as an increase of 11.3 % and 29% for G3 and G4 was observed for the HDPCs, respectively. Significant reduction of MDPC-23 viability occurred for G2 and G3 compared to G1. However, for HDPCs this reduction was only observed in G2 (p<0.05). For both cell cultures used in this study, there was 10 % of cell death by necrosis only in G2, in which the pH of the extract was acid. In G3, where a small amount of TEGDMA was detected in the extracts, there was reduced cell death by necrosis and a discrete morphological alteration in cells. No cellular damage occurred in G4. In general, the MDPC-23 cells are more sensitive than HDPCs against the toxicity of resin cement components. It was found that only the Rely X Luting cement caused intense cytotoxic effect for both pulp cell cultures used in this study. Rely X U200 showed mild cytotoxicity, whereas the cement Rely X ARC was not toxic to the pulp cells. / Mestre
198

Efeito in vivo da deposição de filmes de DLC com e sem nanopartículas de prata sobre liga de titânio para utilização em próteses articulares /

El Abras Ankha, Milagros del Valle. January 2015 (has links)
Orientador: Yasmin Rodarte Carvalho / Co-orientador: Polyana Alves Radi Gonçalves / Banca: Luana Marotta Reis de Vasconcellos / Banca: José Renato Cavalcanti de Queiroz / Resumo: Materiais de revestimento duros para melhorar as propriedades biotribológicas das próteses articulares, estão sendo foco de pesquisa há algum tempo. Vários tipos de filmes de carbono têm sido descritos relatando falhas e sucessos e também sugerindo a necessidade de mais pesquisas. Frente a isso, este trabalho teve o objetivo de avaliar as características estruturais e de neoformação óssea de filmes de carbono tipo diamante com e sem nano-partículas de prata (DLC e DLC-Ag, respectivamente), aplicados por plasma (PECVD) em liga de titânio (Ti-6Al-4V). Sessenta amostras de Ti-6Al-4V, foram dividas em três grupos nos quais: 20 eram recobertas com filme de DLC, 20 com DLC-Ag e 20 sem recobrimento. Após a caracterização estrutural, as amostras foram fixadas bilateralmente no ângulo da mandíbula de 30 coelhos da raça Nova Zelândia. Após os períodos de 15 e 90 dias os animais foram eutanasiados e cinco amostras por grupo foram escolhidas aleatoriamente para a caracterização pósoperatória e cinco para análise qualitativa e quantitativa da neoformação óssea. Os dados foram tratados estatisticamente, por análise descritiva e inferencial, mediante o teste paramétrico ANOVA dois fatores de medidas repetidas e quando foi necessário o teste de comparação múltipla de Tukey (p<0,05%). Verificou-se que os filmes de DLC e DLC-Ag apresentaram alta resistência elétrica e não sofreram grandes modificações em seu espectro Raman, após os períodos de 15 e 90 dias. Na análise histológica após o período de 15 dias, observou-se trabéculas ósseas imaturas proliferando do osso preexistente em direção à amostra e, por vezes, recobrindo parcialmente a superfície da mesma. No período de 90 dias foi difícil delimitar a área de osso neoformado do preexistente, apresentando-se com as características de osso maduro e organizado, abrangendo a interface quase na sua totalidade, na maioria doos casos. Isto foi observado nos três.. / Abstract: Hard coating materials to improve the biotribologic properties of joint prostheses have been the focus of research for some time. Various types of carbon films have been described, reporting failures and successes and also suggesting the need for more research. Because of that, the aim of this work was to evaluate the structural characteristics and biocompatibility of diamond-like carbon films with and without nano-particles of silver (DLC and DLC-Ag, respectively), applied by plasma (PECVD) on a titanium alloy (Ti-6Al-4V). Sixty samples of Ti-6Al-4V, were divided into three groups in which 20 were coated with DLC film, 20 with DLC-Ag and 20 without coating. After the structural characterization, samples were fixed bilaterally in the mandible angle of 20 rabbits of New Zealand race. After periods of 15 and 90 days the animals were euthanized and five samples per group were randomly assigned to postoperative characterization and five for qualitative and quantitative analysis of new bone formation. The data were treated statistically, using descriptive and inferential analysis, by ANOVA parametric test two factors for repeated measures and when necessary, the multiple comparison test of Tukey (p<0.05%). It has been found that the DLC and DLC-Ag films showed high electrical resistance and did not suffer significant changes in its Raman spectrum after periods of 15 and 90 days. Histological examination after 15 days showed proliferating immature bone trabeculae, from the preexisting bone in the direction of the sample and .and sometimes partially covering its surface. At 90 days it was difficult delineate the newly formed bone area of the preexisting. Mature and organized bone was seen within the interface, comprising almost its entirety, in most cases. This was observed in all groups, confirming the results obtained in the histomorphometric analysis, there was no statistically significant ... / Mestre
199

Incorporação do metacrilato 2-tert-butilaminoetil a uma resina acrílica para a base protética: caracterização química e efeito sobre a resistência flexural /

Rodriguez, Larissa Santana. January 2011 (has links)
Orientador: Marco Antonio Compagnoni / Banca: Raphael Freitas de Souza / Banca: Ana Carolina Pero Vizoto / Resumo: A fim de prevenir infecções bucais e consequentemente melhorar a qualidade de vida dos usuários de prótese, diversas tentativas de incorporar agentes antimicrobianos a resinas acrílicas tem sido relatadas na literatura. A incorporação do metacrilato 2-tert-butilaminoetil (TBAEMA) a uma resina acrílica para base protética seria uma alternativa plausível no intuito de se reduzir ou eliminar a colonização dessa superfície por microrganismos patogênicos, pois esta substância apresenta grupos amina em sua composição, o que poderia indicar uma possível atividade antimicrobiana da base protética. Objetivo: O objetivo deste trabalho foi investigar a interação química entre o TBAEMA e a resina acrílica bem como a presença de grupos amina na superfície da resina, e ainda avaliar a temperatura de transição vítrea e a resistência à flexão da resina após a incorporação de TBAEMA. Material e método: Os espécimes foram divididos em cinco grupos de acordo com as concentrações de TBAEMA incorporadas à resina Onda-Cryl: 0%, 1%, 2%, 3% e 4%. A superfície dos espécimes foi avaliada por meio de Espalhamento Superficial de Elétrons com Análise Química (XPS-ESCA) para detectar a presença de grupos amina, representado por índices de nitrogênio. As análises de Espectroscopia de Infravermelho por Transformada de Fourier (FTIR) e Calorimetria Diferencial de Varredura (DSC) foram utilizadas para avaliar o processo de polimerização da resina 17 acrílica na presença do TBAEMA e a influência da incorporação do TBAEMA na temperatura de transição vítrea (Tg) da resina, respectivamente. A resistência à flexão dos espécimes também foi avaliada e os resultados foram analisados por meio de análise de variância a um fator (ANOVA) seguido pelo teste de Tukey ( <0.05). Resultados: Foram observados diferentes índices de nitrogênio: 0,36%, 0,54%, 0,35% e 0,20% para... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: With a purpose of to prevent oral infections and therefore improve the quality of life of dentures wearers, several attempts to incorporate antimicrobial agents into acrylic resins have been reported in the literature. The incorporation of 2-tert-butylaminoethyl methacrylate (TBAEMA) into denture base acrylic resin would be a plausible alternative in order to reduce or eliminate colonization of that surface by pathogenic microorganisms, on this account this substance has amine groups in their composition, which could indicate a possible antimicrobial activity of the denture base. Purpose: The purpose of this study was to investigate the chemical interaction between the TBAEMA and acrylic resin and the presence of amine groups in the resin surface, and assess the glass transition temperature and flexural strength of the resin after the incorporation TBAEMA. Material and Method: The specimens were divided in five groups according to the concentration of TBAEMA incorporated to Onda-Cryl: 0%, 1%, 2%, 3% and 4%. Specimens surfaces were evaluated by Electron Spectroscopy for Chemical Analysis (ESCA) to detect the presence of amino groups, represented by nitrogen ratios. Fourier Transform Infrared Spectroscopy (FTIR) and Differential Scanning Calorimetry (DSC) analysis were used to evaluate the polymerization process of acrylic resin in the presence of TBAEMA and the influence of the incorporation of TBAEMA on the glass transition temperature (Tg) of acrylic resin, respectively. Flexural strength of the... (Complete abstract click electronic access below) / Mestre
200

Avaliação da força mastigatória e da atividade eletromiográfica dos músculos masseter e temporal em função de diferentes tratamentos reabilitadores /

Gomes, Isabela Silva. January 2011 (has links)
Resumo: A função mastigatória é um dos mais complexos mecanismos neuropsicológicos no desempenho motor humano, dependendo de vários fatores como força de mordida, coordenação dos músculos, morfologia e número de dentes em oclusão. O objetivo desse trabalho é quantificar a força mastigatória máxima e analisar eletromiograficamente os músculos elevadores mandibulares de pacientes dentados totais (n=52) e reabilitados com prótese total (PT) (n=28) e prótese parcial removível (PPR) (n=27), a fim de verificar a influência de diferentes tratamentos reabilitadores na força mastigatória e atividade dos músculos masseter e temporal. A coleta dos dados de força de mordida (FM) e atividade eletromiográfica (EMG) foi realizada em triplicata em repouso e em contração isométrica através de um transdutor de força de mordida (desenvolvido pelos autores) e um eletromiógrafo EMG-800c de oito canais (EMG System do Brasil Ltda). Outras variáveis como gênero, idade, peso, estresse, prática de atividade física, lado preferencial da mastigação, formato facial e consistência da alimentação também foram levantadas e comparadas às variáveis FM e EMG em função dos grupos experimentais. Os valores de força de mordida (em Kgf) e os sinais eletromiográficos (em voltagem RMS) dos músculos masseter e temporal direito e esquerdo foram submetidos à estatística descritiva e comparados em função dos grupos experimentais por meio do teste estatístico de Análise de Variância 1 fator (ANOVA) e ao teste Tukey com nível de significância de 5%. Com relação à FM, o grupo controle (51,49 ± 16,24)A apresentou média estatisticamente superior (p=0,00<0,05) ao grupo PPR(28,45 ± 15,43)B e PT (13,11 ± 7,69)C . Com relação à EMG, em repouso... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The chewing is one of the most complex neuropsychological mechanisms in human motor performance, depending on various factors such as bite force, muscle coordination, morphology and number of teeth in occlusion. The aim of this study is to quantify the maximum bite force and analysis electromyographic of the jaw elevators muscles of dentate patients (n = 52) and rehabilitated with complete denture (CD) (n = 28) and removable partial dentures (RPD) (n = 27) in order to check the influence of different rehabilitation treatments in bite force and activity of the masseter and temporal. Data collection of bite force (BF) and electromyographic activity (EMG) was performed in triplicate at rest and during isometric contraction with a bite force transducer (developed by the authors) and an electromyograph EMG-800c eight-channel (EMG System do Brazil Ltda.) Other variations such as gender, age, weight, stress, physical activity, preferred side of chewing, facial shape and consistency of supply were also raised compared to variables BF and EMG as a function of the experimental groups. The values of bite force (kgf) and the electromyographic signals (RMS voltage) of the masseter and temporal right and left were subjected to descriptive statistics and compared on the basis of the experimental groups using the statistical test of a factor analysis of variance (ANOVA) and Tukey's test at a significance level of 5%. With respect to BF, the control group (51.49 ± 16.24) had statistically significant higher (p = 0.00 <0.05)A than PPR group (28.45 ± 15.43)B and PT (13 , 11 ± 7.69)C. Regarding the EMG at rest showed no statistical difference between any of the muscles (p> 0.05). In isometric contraction, however, the control group... (Complete abstract click electronic access below) / Orientador: Clovis Pagani / Coorientador: José Benedito Oliveira Amorim / Banca: Eduardo Galera da Silva / Banca: Rubens Côrte Real de Carvalho / Mestre

Page generated in 0.0346 seconds