• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 28
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 28
  • 28
  • 16
  • 13
  • 7
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Artroplastia total híbrida nacional em cães Portadores de displasia coxofemoral

Rossetto, Victor José Vieira [UNESP] 16 March 2015 (has links) (PDF)
Made available in DSpace on 2016-06-07T17:12:13Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-03-16. Added 1 bitstream(s) on 2016-06-07T17:16:48Z : No. of bitstreams: 1 000859208_20170316.pdf: 96768 bytes, checksum: 4cbdf569b6df05c1b8d5b67b81321f18 (MD5) Bitstreams deleted on 2017-03-17T12:38:07Z: 000859208_20170316.pdf,. Added 1 bitstream(s) on 2017-03-17T12:39:08Z : No. of bitstreams: 1 000859208.pdf: 738633 bytes, checksum: c7ad09705495ab495cb631dcdc05db78 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / A artroplastia total coxofemoral de uma maneira geral é a técnica cirúrgica mais indicada para o tratamento da displasia coxofemoral grave em humanos e cães, e consiste na substituição das extremidades ósseas que compõem a articulação por componentes protéticos. O objetivo do presente trabalho foi avaliar a artroplastia total modular híbrida, desenvolvida no Brasil, como opção de tratamento para casos de displasia coxofemoral moderada ou grave até 180 dias de pós-operatório, bem como a frequência das suas potenciais complicações. Para isso, foram utilizados 10 animais da espécie canina, de raças variadas, esqueleticamente maduros, machos e fêmeas, portadores de displasia coxofemoral moderada ou grave, e submetidos ao procedimento de artroplastia total utilizando-se componente femoral cimentado de cabeça intercambiável e componente acetabular não cimentado. Os cães foram avaliados por meio de exames ortopédico e radiográfico no período pósoperatório imediato, e aos 30, 60, 120 e 180 dias após a cirurgia; e exame tomográfico no período pós-operatório imediato, e aos 120 e 180 dias de pós-operatório. Com relação à avaliação da função locomotora e intensidade de dor, o procedimento cirúrgico conferiu melhora em, respectivamente, 60% e 90% dos animais avaliados. Dentre os animais selecionados, seis (60%) apresentaram complicações pós-operatórias. As principais complicações verificadas incluíram infecção, soltura asséptica do componente acetabular, luxação do componente femoral em relação ao acetabular e fratura femoral periprostética. A seleção dos proprietários e animais deve ser rigorosa na tentativa de reduzir sobremaneira as complicações verificadas / Total hip arthroplasty is generally the most commonly performed surgical technique for severe hip dysplasia treatment in humans and dogs, and consists of the replacement of the hip joint by prosthetic components. The aim of this study was to evaluate the hybrid total arthroplasty, developed in Brazil, as a treatment option for dogs with moderate or severe hip dysplasia up to 180 days after surgery by clinical, radiographical and tomographical evaluations, and the frequency of the potential complications. For this, we utilized 10 dogs of variable breeds, skeletally mature, male and female, with moderate or severe hip dysplasia and submitted to total hip arthroplasty using cemented femoral component of exchangeable head and cementless acetabular component. The dogs were evaluated by orthopaedic and radiographical examinations at imediate postoperative period, and at 30, 60, 120 and 180 days after surgery; and by CT scan at imediate postoperative period, and at 120 and 180 days after surgery. Surgery conferred improvement of the locomotor function and intensity of pain in, respectively, 60% and 90% of the evaluated animals. Among the selected animals, six (60%) had postoperative complications. Major complications included infection, aseptic loosening of the femoral component, femoral component dislocation and femoral periprosthetic fracture. The selection of owners and animals must be rigorous in trying to greatly reduce the complications observed
2

Artroplastia total híbrida nacional em cães Portadores de displasia coxofemoral /

Rossetto, Victor José Vieira. January 2015 (has links)
Orientador: Claúdia Valéria Seullner Brandão / Banca: Gilberto José Cação Pereira / Banca: Bruno Watanabe Minto / Banca: Luiz Carlos Vulcano / Banca: Priscilla Macedo de Souza / Resumo: A artroplastia total coxofemoral de uma maneira geral é a técnica cirúrgica mais indicada para o tratamento da displasia coxofemoral grave em humanos e cães, e consiste na substituição das extremidades ósseas que compõem a articulação por componentes protéticos. O objetivo do presente trabalho foi avaliar a artroplastia total modular híbrida, desenvolvida no Brasil, como opção de tratamento para casos de displasia coxofemoral moderada ou grave até 180 dias de pós-operatório, bem como a frequência das suas potenciais complicações. Para isso, foram utilizados 10 animais da espécie canina, de raças variadas, esqueleticamente maduros, machos e fêmeas, portadores de displasia coxofemoral moderada ou grave, e submetidos ao procedimento de artroplastia total utilizando-se componente femoral cimentado de cabeça intercambiável e componente acetabular não cimentado. Os cães foram avaliados por meio de exames ortopédico e radiográfico no período pósoperatório imediato, e aos 30, 60, 120 e 180 dias após a cirurgia; e exame tomográfico no período pós-operatório imediato, e aos 120 e 180 dias de pós-operatório. Com relação à avaliação da função locomotora e intensidade de dor, o procedimento cirúrgico conferiu melhora em, respectivamente, 60% e 90% dos animais avaliados. Dentre os animais selecionados, seis (60%) apresentaram complicações pós-operatórias. As principais complicações verificadas incluíram infecção, soltura asséptica do componente acetabular, luxação do componente femoral em relação ao acetabular e fratura femoral periprostética. A seleção dos proprietários e animais deve ser rigorosa na tentativa de reduzir sobremaneira as complicações verificadas / Abstract: Total hip arthroplasty is generally the most commonly performed surgical technique for severe hip dysplasia treatment in humans and dogs, and consists of the replacement of the hip joint by prosthetic components. The aim of this study was to evaluate the hybrid total arthroplasty, developed in Brazil, as a treatment option for dogs with moderate or severe hip dysplasia up to 180 days after surgery by clinical, radiographical and tomographical evaluations, and the frequency of the potential complications. For this, we utilized 10 dogs of variable breeds, skeletally mature, male and female, with moderate or severe hip dysplasia and submitted to total hip arthroplasty using cemented femoral component of exchangeable head and cementless acetabular component. The dogs were evaluated by orthopaedic and radiographical examinations at imediate postoperative period, and at 30, 60, 120 and 180 days after surgery; and by CT scan at imediate postoperative period, and at 120 and 180 days after surgery. Surgery conferred improvement of the locomotor function and intensity of pain in, respectively, 60% and 90% of the evaluated animals. Among the selected animals, six (60%) had postoperative complications. Major complications included infection, aseptic loosening of the femoral component, femoral component dislocation and femoral periprosthetic fracture. The selection of owners and animals must be rigorous in trying to greatly reduce the complications observed / Doutor
3

Âncora de titânio na sutura iliofemoral para tratamento de luxação coxofemoral traumática em cães : descrição da técnica e estudo de 12 casos /

Rocha, Artur Gouveia. January 2017 (has links)
Orientador: João Guilherme Padilha Filho / Banca: Gustavo Garkalns de Souza Oliveira / Banca: Elói dos Santos Portugal / Banca: Paola Castro Moraes / Banca: Márcia Rita Fernandes Machado / Resumo: As técnicas cirúrgicas extra-articulares para estabilização do qua-dril luxado têm sido mais estudadas, tendo em vista a manutenção da integridade da cartilagem articular e a redução da progressão da doença articular degenerativa. Den-tre estas técnicas, a sutura de fixação iliofemoral, tem se mostrado efetiva, com boa recuperação dos pacientes. O propósito deste trabalho foi avaliar a âncora de titânio como método de fixação do fio se sutura ao ílio, substituindo, assim, na técnica de fixação iliofemoral, a trabalhosa manobra de passagem do material de sutura através de um túnel no corpo ilíaco. Esta técnica foi realizada em 12 cães, de raças variadas, atendidos no Hospital Veterinário da UNESP - Jaboticabal. Os pacientes, em sua to-talidade, vítimas de atropelamento, se apresentaram com diferentes graus de claudi-cação e dor no quadril. Em alguns casos, ocorreram reluxações após tentativas de redução fechada e esses pacientes foram submetidos redução e fixação cirúrgica da luxação por meio da sutura iliofemoral modificada. Os pacientes foram acompanhados clínica e radiograficamente por períodos variados entre 30 a 90 dias de pós-operatório. Observou-se apoio com carga no membro em média de três dias após os procedi-mentos e aos 10 dias a maioria dos pacientes não claudicava. Não foram visibilizadas, no exame radiográfico osteólise perimplante. A sutura ílio femoral, modificada pela utilização de uma âncora fixada ao ílio, mostrou-se eficiente no tratamento da luxação coxofe... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Extra-articular surgical techniques for stabilization of dislocated hip have been most studied, with a view to maintaining the integrity of articular cartilage and reducing the progression of degenerative joint disease. Among these techniques, the suture fixation iliofemoral, has proven effective, with good recovery of patients. The purpose of this study was to evaluate the anchor titanium as the wire clamping method suture the ileum, thus replacing, in the iliofemoral fixation technique, the laborious ma-neuvering passage of suture material through a tunnel in iliac body. This technique was performed in 10 dogs of various races attended at UNESP Veterinary Hospital - Jaboticabal. The patients, in its entirety, victims of trampling presented with varying degrees of lameness and pain in the hip. In some cases, attempts occurred after reluxações closed reduction and forami these patients undergoing surgical fixation and reduction of the dislocation by modified iliofemoral suture. The patients were followed clinically and radiographically for varying periods between 30 to 90 days postopera-tively. He observed the load support member on average 3 days after the procedure and 10 days most patients do not limping. There were visualized on radiographic ex-amination, perimplante osteolysis, or the appearance of osteophytes or joint sclerosis. The ilium femoral suture, modified by the use of an anchor attached to the ilium, was efficient in the treatment of hip dislocation, not being observed dislocation recurrence. Additionally, the use of titanium anchor greatly facilitating the fixing of the wire ilium, significantly reducing surgical time. / Doutor
4

Desenvolvimento de um equipamento para análise de desgastes em prótese de articulação total de quadril / Development of an equipament for analysis of wear of the componentes of total hip prosthesis

Haddad, Michel [UNESP] 07 January 2015 (has links) (PDF)
Made available in DSpace on 2015-04-09T12:28:10Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-01-07Bitstream added on 2015-04-09T12:48:06Z : No. of bitstreams: 1 000817132.pdf: 851137 bytes, checksum: e912d75616dc0496ca2afdbf7e4e1583 (MD5) / O incremento da renda brasileira aliado ao aumento da expectativa de vida, juntamente com outros fatores, propiciaram condições para a elevação da demanda por cirurgias de prótese de articulação total de quadril. A ausência de uma norma reguladora para a durabilidade mínima destas próteses fez surgir no mercado uma grande variedade de produtos que não atendem requisitos mínimos de uso, causando elevado número de cirurgias mal sucedidas e trazendo transtornos aos pacientes. Os ensaios para verificação da durabilidade das próteses realizados no território nacional utilizam, em sua maioria, equipamentos importados, com alto grau de sofisticação, tornando-os de custo elevado. Sendo o Sistema Único de Saúde (SUS) o maior adquirente destas próteses, torna-se inviável manter uma rotina de ensaios com a finalidade de avaliar a qualidade do produto a ser adquirido e oferecido aos pacientes. O projeto e montagem de um equipamento viável nas etapas de fabricação, operação e manutenção visa atender esta demanda com maior abrangência, proporcionando ensaios acessíveis. O atendimento das normas específicas, com alguns ajustes, viabilizou a operação do equipamento e as análises de exemplares de próteses, o que comprovou a viabilidade do projeto e o seu grau de atendimento a necessidade da realidade brasileira. Foi realizado um teste realizado com um conjunto protético por um período de 12 dias, totalizando 1 milhão de ciclos. Ao final obteve-se o desgaste da massa do componente acetabular em polímero, e calculou-se o fator de desgaste (K). O simulador apresentou funcionamento adequado, produziu o perfil da carga prescrita pela Norma Técnica e o fator de desgaste obtido foi considerado adequado / The increase of Brazilian income coupled with the increase in life expectancy, along with other factors, led to the conditions for the rise of demand for surgeries of total hip joint prosthesis. The absence of a regulatory standard for the minimum durability of these prostheses did arise on the market a great variety of products that do not meet minimum requirements of use, causing large numbers of unsuccessful surgeries and bringing patients disorders. The tests for verification of the durability of prosthetics carried out in national territory using, for the most part, imported equipment, with a high degree of sophistication, making them high cost. Being the Sistema Único de Saúde (SUS) the largest purchaser of these prostheses, it becomes impossible to maintain a routine tests in order to evaluate the quality of the product to be purchased and offered to patients. The design and assembly of a viable equipment in stages of manufacturing, operation and maintenance aims to meet this demand with greater scope, providing affordable tests. Meet the specific standards, with some adjustments, made the operation of the equipment and the analysis of specimens of prostheses, which proved the feasibility of the project and its degree of care the need of Brazilian reality. It was conducted a test performed with a prosthetic assembly for a period of 12 days, totalizingng 1 million cycles. At the end, it was obtained the mass wear of the acetabular component in polymer, and it has been calculated the wear factor (K). The simulator showed proper functioning, produced the prescribed load profile by Technic Norm and the wear factor obtained was considered appropriate
5

Desenvolvimento de um equipamento para análise de desgastes em prótese de articulação total de quadril /

Haddad, Michel. January 2015 (has links)
Orientador: Mauro Pedro Peres / Coorientador: Marcelino Pereira do Nascimento / Banca: José Geraldo Trani Brandão / Banca: Marcelos Sampaio Martins / Banca: Renata Aparecida Ribeiro Custódio / Banca: Henrique Martins Rocha / Resumo: O incremento da renda brasileira aliado ao aumento da expectativa de vida, juntamente com outros fatores, propiciaram condições para a elevação da demanda por cirurgias de prótese de articulação total de quadril. A ausência de uma norma reguladora para a durabilidade mínima destas próteses fez surgir no mercado uma grande variedade de produtos que não atendem requisitos mínimos de uso, causando elevado número de cirurgias mal sucedidas e trazendo transtornos aos pacientes. Os ensaios para verificação da durabilidade das próteses realizados no território nacional utilizam, em sua maioria, equipamentos importados, com alto grau de sofisticação, tornando-os de custo elevado. Sendo o Sistema Único de Saúde (SUS) o maior adquirente destas próteses, torna-se inviável manter uma rotina de ensaios com a finalidade de avaliar a qualidade do produto a ser adquirido e oferecido aos pacientes. O projeto e montagem de um equipamento viável nas etapas de fabricação, operação e manutenção visa atender esta demanda com maior abrangência, proporcionando ensaios acessíveis. O atendimento das normas específicas, com alguns ajustes, viabilizou a operação do equipamento e as análises de exemplares de próteses, o que comprovou a viabilidade do projeto e o seu grau de atendimento a necessidade da realidade brasileira. Foi realizado um teste realizado com um conjunto protético por um período de 12 dias, totalizando 1 milhão de ciclos. Ao final obteve-se o desgaste da massa do componente acetabular em polímero, e calculou-se o fator de desgaste (K). O simulador apresentou funcionamento adequado, produziu o perfil da carga prescrita pela Norma Técnica e o fator de desgaste obtido foi considerado adequado / Abstract: The increase of Brazilian income coupled with the increase in life expectancy, along with other factors, led to the conditions for the rise of demand for surgeries of total hip joint prosthesis. The absence of a regulatory standard for the minimum durability of these prostheses did arise on the market a great variety of products that do not meet minimum requirements of use, causing large numbers of unsuccessful surgeries and bringing patients disorders. The tests for verification of the durability of prosthetics carried out in national territory using, for the most part, imported equipment, with a high degree of sophistication, making them high cost. Being the Sistema Único de Saúde (SUS) the largest purchaser of these prostheses, it becomes impossible to maintain a routine tests in order to evaluate the quality of the product to be purchased and offered to patients. The design and assembly of a viable equipment in stages of manufacturing, operation and maintenance aims to meet this demand with greater scope, providing affordable tests. Meet the specific standards, with some adjustments, made the operation of the equipment and the analysis of specimens of prostheses, which proved the feasibility of the project and its degree of care the need of Brazilian reality. It was conducted a test performed with a prosthetic assembly for a period of 12 days, totalizingng 1 million cycles. At the end, it was obtained the mass wear of the acetabular component in polymer, and it has been calculated the wear factor (K). The simulator showed proper functioning, produced the prescribed load profile by Technic Norm and the wear factor obtained was considered appropriate / Doutor
6

Avaliação morfofuncional e ultraestrutural do desenvolvimento da articulação do quadril em fetos humanos / Morphofunctional and ultrastructural evaluation of hip joint development in human fetuses

Simões, Mariane Cristina Donato 13 September 2018 (has links)
O desenvolvimento da articulação do quadril tem sido de intenso interesse devido à escassa informação acerca dos aspectos morfológicos e ultraestruturais em fetos humanos de diferentes faixas etárias. Pretende-se avaliar os aspectos morfofuncionais e ultraestruturais do desenvolvimento da cartilagem articular da epífise da cabeça do fêmur. Foram utilizados 20 fetos humanos de idades compreendidas entre 16 a 31 semanas de vida intra uterina (VIU), fixados em solução de formol a 10% e conservados em glicerina. Os fetos foram divididos em 4 grupos (n=5): grupo 1 (G1): 16-19 semanas VIU; grupo 2 (G2): 20-23 semanas VIU; grupo 3 (G3): 24-27 semanas VIU e grupo 4 (G4): 28-31 semanas VIU. Os espécimes foram divididos em uma metade anterior e outra, posterior através de um corte frontal em sua parte média. Os antímeros direitos foram processados através da microscopia de luz para análise quantitativa a fim de determinar a área, a densidade dos condrócitos e de matriz extracelular (MEC), e o volume e para análise qualitativa a fim de determinar a distribuição e organização das fibras colágenas na MEC através da coloração da Safranina-O e do Picro-sirius. Os antímeros esquerdos foram submetidos à microscopia eletrônica de varredura. Foram encontradas diferenças significantes entre os grupos com o aumento da área e do volume de condrócitos com a avanço das idades de forma gradativa. Quanto maior a faixa etária, menor o número de condrócitos, e maior a densidade percentual de matriz extracelular. Através da microscopia eletrônica de varredura (MEV), na superfície da epífise, a organização e orientação das fibras de colágeno mudaram nos diferentes grupos, de uma orientação irregular no grupo de fetos mais jovens, para uma organização pantográfica no grupo de fetos mais desenvolvidos. Conhecer a organização e o desenvolvimento normal cartilagíneo da cabeça do fêmur contribui com conhecimentos morfológicos para entender melhor a maturação do colágeno nos locais de reparo dos tecidos e embasar aspectos relacionados a doenças e malformações da articulação. / The development of the hip joint has been of intense interest due to the scarce information about the morphological and ultrastructural aspects in human fetuses of different age groups. It is intended to evaluate the morphofunctional and ultrastructural aspects of the development of the articular cartilage of the epiphysis of the femoral head. Twenty human fetuses aged between 16 and 31 weeks of intrauterine life (IUL), fixed in 10% formalin solution and preserved in glycerin, were used. Fetuses were divided into 4 groups (n = 5): group 1 (G1): 16-19 weeks VIU; group 2 (G2): 20-23 weeks VIU; group 3 (G3): 24-27 weeks VIU and group 4 (G4): 28-31 weeks VIU. The specimens were divided into an anterior half and a posterior one through a frontal cut in the middle part. The right antimers were processed by light microscopy for quantitative analysis to determine the area, chondrocyte density and extracellular matrix (ECM), and volume and for qualitative analysis in order to determine the distribution and organization of collagen fibers in MEC through the staining of Safranin-O and Picrosirius. The left antimers were submitted to scanning electron microscopy. Significant differences were found between groups with increasing area and volume of chondrocytes with advancing age gradually. The higher the age group, the lower the number of chondrocytes, and the higher the percentage density of extracellular matrix. Through scanning electron microscopy (SEM), on the surface of the epiphysis, the organization and orientation of the collagen fibers changed in the different groups, from an irregular orientation in the group of younger fetuses, to a pantographic organization in the group of more developed fetuses. Knowing the normal organization and development of the cartilaginous head of the femur contributes with morphological knowledge to better understand the maturation of collagen in the tissue repair sites and to support aspects related to diseases and malformations of the joint.
7

Estudo eletromiográfico dos músculos adutor longo e vasto medial (fibras oblíquas), durante exercícios de agachamento com e sem a adução do quadril / Electromyographic study of the adductor longus and vastus medialis muscles (oblique fibers), during squatting exercises with and without hip adduction

Passos, Fabio de Faro 29 September 2006 (has links)
INTRODUÇÃO: os músculos adutor longo (ADL) e vasto medial (VM), incluindo suas fibras oblíquas (VMO), possuem relações anatômicas e funcionais. O músculo VMO é estabilizador da patela, portanto inúmeros trabalhos EMG procuram determinar exercícios que aumentem a atividade deste músculo. Este estudo teve como objetivo relacionar a atividade do músculo VMO com a adução do quadril e com a contração do músculo ADL em exercícios de agachamento com e sem apoio dorsal para ambos os sexos. CASUÍSTICA E MÉTODOS: participaram trinta indivíduos saudáveis e sedentários de ambos os sexos, com idade média 19 ± 1,4 anos, estatura média 162,2 ± 6,8 cm, massa corporal média de 64,8 ± 11,4 kg e IMC de 19,26 ± 0,84. Realizaram exercícios de agachamento na parede (AP), de agachamento na parede com adução do quadril (APA), de agachamento livre (AL) e de agachamento livre com adução do quadril (ALA). Para cada exercício foram realizados três agachamentos no arco de 0o - 60º - 0o de flexão do joelho. Os sinais EMG foram retificados e quantificados pelo uso do RMS, foram então normalizados a partir de CIVM. Foram realizados testes estatísticos e o nível de significância adotado foi a < 0,05. RESULTADOS: os exercícios APA e ALA mostraram aumento significativo de atividade elétrica do músculo VMO; o músculo ADL foi significativamente mais ativo no exercício APA e ALA; não se observaram diferenças significativas entre os músculos durante as repetições dos exercícios; o músculo ADL foi significativamente mais ativo durante o exercício APA em comparação com o exercício ALA; o músculo VMO foi significativamente mais ativo no exercício AP em comparação com o AL; o músculo ADL foi significativamente mais ativo para os indivíduos do sexo feminino; o músculo VMO foi significativamente mais ativo para os indivíduos do sexo feminino somente no exercício APA; para todos os exercícios o músculo VMO foi significativamente mais ativo que o músculo ADL. CONCLUSÕES: a contração do músculo ADL durante a adução do quadril elevou a atividade do músculo VMO, sendo este aumento maior nos exercícios de agachamento com apoio dorsal e para os indivíduos do sexo feminino. / SUMMARY: Adductor longus (ADL) and vastus medialis (VM) muscles, including their oblique fibers (VMO), have anatomic relations. VMO muscle is a patella stabilizer, thus a number of EMG studies have been written in order to determine exercises that increase this muscle activity. The present study aimed at relating VMO muscle activity to hip adduction and ADL muscle contraction at squatting exercises with and without back support for both sexes. CASUISTICS AND METHODS: thirty healthy and sedentary individuals of both sexes took part in the study, being average age 19 ± 1,4 years old, average height 162,2 ± 6,8 cm, average body weight 64,8 ± 11,4 kg and average IMC 19,26 ± 0,84. They did squatting exercises on the wall (WS), squatting exercises on the wall with hip adduction (WSA), free squatting exercises (FS) and free squatting exercises with hip adduction (FSA). In each exercise, three complete 0o - 60o - 0o knee flexion squatting exercises were realized. EMG signals were rectified and quantified by using RMS and then normalized from MIVC. Statistical tests were made and the significance level adopted was a < 0,05. RESULTS: WSA and FSA exercises showed significant increase in the electrical activity of the VMO muscle; ADL muscle was significantly more active in WSA and FSA exercises; significant differences between the muscles were not observed during exercise repetitions; ADL muscle was significantly more active during WSA exercise in comparison to FSA exercise; VMO muscle was significantly more active in WS exercise in comparison to the FS one; ADL muscle was significantly more active for female individuals; VMO muscle was significantly more active for female individuals only in WSA exercise; in all the exercises, VMO muscle was significantly more active than ADL muscle. CONCLUSIONS: the ADL muscle contraction during hip adduction increased the VMO muscle activity; being this increase greater for squatting exercises with back support and for female individuals.
8

Cinemática de cães da raça pastor alemão hígidos em displasia coxofemoral /

Miqueleto, Nélida Simone Martinez Landeira. January 2012 (has links)
Orientador: Sheila Canevese Rahal / Coorientador: Alexander Oliveira El-Warrak / Banca: Alfredo Feio da Maia Lima / Banca: Bruno Watanabe Minto / Resumo: O trabalho teve por objetivos avaliar padrões cinemáticos dos membros torácicos e pélvicos em cães hígidos da raça Pastor Alemão, ao trote em esteira, e compará-los com cães displásicos da mesma raça sem sinais clínicos de claudicação, para determinar a viabilidade do método como contribuinte diagnóstico. Foi utilizado um total de 20 cães, divididos em dois grupos equitativos, a saber: Grupo 1 - cães hígidos, seis machos e quatro fêmeas, com peso médio de 27,3 a 46 kg (média = 35,76 kg, DP= 5,87) e idade entre 2 e 7 anos (média de 3,55 anos); Grupo 2 - cães com displasia coxofemoral, cinco machos e cinco fêmeas, com peso entre 29 e 41,6 (média = 35,33 kg; DP= 4,36) e idade variando de 1 a 5 anos (média de 3,35 anos). Os dados cinemáticos foram coletados com o emprego de três câmeras e analisados por um programa de análise de movimento. Foram registrados os valores angulares e a velocidade angular das articulações do ombro, cotovelo, do carpo, coxofemoral, joelho e do tarso. Em ambos os Grupos não foram observadas diferenças na média entre os membros pélvicos ou entre os membros torácicos em todas as variáveis analisadas. Não ocorreu diferença de valores angulares entre os Grupos. Para a velocidade angular foram observadas diferenças na velocidade angular máxima da articulação coxofemoral (displásico>hígido) e do carpo (hígido>displásico). Foi possível concluir que cães displásicos sem sinais clínicos de claudicação podem apresentar ao trote alterações cinemáticas tanto nos membros pélvicos como torácicos / Abstract: The aim of this study was to establish kinematic patterns in clinically normal German shepherd dogs and to compare with dogs of the same breed with hip dysplasia with no clinical signs of lameness to determine the importance as auxiliary diagnosis method. Twenty intact German shepherd trotting on a treadmill at a constant speed were used. Ten clinically healthy dogs, 6 males and 4 females, weighing 27.3-46 kg (mean 35.76 kg ± 5.87 SD), and aged from 2 to 7 years (mean 3.55 years) (G1), and 10 dogs with hip dysplasia, weighing 29-41.6 kg (mean 35.33 kg ± 4.36 SD), and aged from 1 to 5 years (mean 3.35 years) (G2). Kinematic data were collected by use of a 3-camera system. Data were analyzed by use of a motion-analysis program. Flexion and extension joint angles, angular velocity and angular acceleration were determined for the shoulder, elbow, carpal, hip, stifle, and tarsal joints. Within each group, the differences between the right and left limbs in all kinematic variables were not significant. No differences were observed in joint angles (maximum, minimum, displacement) between Groups. Significant differences were observed in the maximum angular velocity of the hip joint (dysplastic>healthy) and carpal joint (healthy>dysplastic). In conclusion, dysplastic dogs with no signs of lameness trotting on a treadmill may present joint kinematic alterations in the hind limbs as well as forelimbs / Mestre
9

Avaliação de modelo tridimensional não invasivo da articulação coxofemoral em ovinos hígidos

Agostinho, Felipe Stefan. January 2015 (has links)
Orientador: Sheila Canevese Rahal / Banca: Carlos Roberto Teixeira / Banca: Lidia Mitsuko Matsubara / Banca: Joel Mesa Hormaza / Banca: André Luis Selmi / Resumo: O trabalho teve por objetivos propor e avaliar modelo cinemático tridimensional não invasivo da articulação coxofemoral de ovinos, usando sistema de coordenada articular, bem compará-lo e correlacioná-lo a dois modelos sagitais. Para tanto, foram utilizados oito ovinos hígidos de porte semelhante, não castrados, fêmeas, com idade entre 2 e 4 anos. Para o cálculo dos ângulos foram aplicados três modelos matemáticos, um sistema de coordenada articular (SCA) e dois modelos sagitais, sendo um linear (MSL) e um segmentar (MSS). Os modelos SCA, MSL e MSS permitiram a captura dos ângulos de flexão/extensão e abdução/adução. Adicionalmente o modelo SCA permitiu a captura dos ângulos de rotação interna/externa. Os ângulos máximos, mínimos e deslocamentos angulares para cada uma das variáveis foram avaliados. Na comparação entre SCA e MSL não foram observadas diferenças significativas para flexão/extensão e abdução/adução. Já nas comparações de MSL/MSS e SCA/MSS, excetuando-se o deslocamento angular em flexão/extensão entre SCA/MSS, foram observadas diferenças significativas para flexão/extensão e abdução/adução, nas demais variáveis. Os valores dos ângulos de rotação interna/externa apresentaram alta variabilidade. Não houve correlação significativa no deslocamento angular de abdução/adução entre MSL e MSS, porém todas as demais correlações entre modelos foram significativas. Foi possível concluir que os ângulos de flexão/extensão e abdução/adução adquiridos com o sistema de coordenada articular foram similares com o modelo sagital linear, mas não com o modelo sagital segmentar. Os dados de rotação interna/externa determinados pelo sistema de coordenada articular podem não ser aplicáveis / Abstract: The aim of this study was to develop and evaluate a noninvasive three-dimensional model of the hip joint in sound sheep using a joint coordinate system, and to compare and correlate it with two sagittal models. Eight sound sheep of similar size, intact, female, aged from 2 to 4 years were used. Three models were used to angle calculations including joint coordinate system (SCA), and sagittal linear (MSL) and sagittal segmental model (MSS). The SCA, MSL and MSS models were able to capture flexion/extension and abduction/adduction angles whereas SCA model also was able to capture internal/external rotation angle. Maximum angle, minimum angle and angular displacement were calculated for all variables. Comparing SCA to MSL, significant differences were not observed. Differences were observed in all comparisons between SCA/MSS and MSL/MSS, except for flexion/extension displacement between SCA/MSS that was similar. The values of internal/external rotation angles showed high variability. The correlations were significant for both flexion/extension and abduction/adduction angles in the three models, except for abduction/adduction displacement between MSL/MSS. In conclusion, the flexion/extension and abduction/adduction angles obtained with joint coordinate system were similar to sagittal linear, but not with sagittal segmental model. The internal/external rotation angle data obtained by joint coordinate system may not be useful / Doutor
10

Avaliação da fadiga no ciclismo por meio da análise dos momentos articulares resultantes / Fatigue evaluation by means of the analisys of resultant joint moments

Bini, Rodrigo Rico January 2008 (has links)
O processo de instalação da fadiga implica na mudança do padrão coordenativo durante a pedalada. Desta forma a análise da contribuição de cada articulação do membro inferior para o somatório absoluto dos momentos articulares se faz necessária para o melhor entendimento dos mecanismos relacionados aos efeitos do processo de instalação da fadiga sobre o padrão coordenativo no ciclismo. O objetivo deste estudo foi comparar a contribuição das articulações do quadril, joelho e tornozelo para o somatório absoluto dos momentos articulares resultantes, assim como a força resultante e a cinemática destas articulações, ao longo do tempo, nos modelos experimentais de carga constante e de carga incremental até a exaustão. Foram avaliados onze ciclistas de estrada da categoria elite, que participam de competições regionais (Texas) e nacionais (Estados Unidos) do sexo masculino (idade 31 ± 7 anos; consumo máximo de oxigênio 62,84 ± 4,86 ml.kg-1.min-1; potência máxima 407 ± 37 W). Onze ciclistas foram avaliados no primeiro dia de avaliação, este constituindo um teste de ciclismo máximo com incrementos de carga a cada dois minutos (75, 90 e 100% da PO máxima estimada, respectivamente). No segundo dia de avaliação, dez ciclistas foram avaliados em um protocolo de ciclismo com carga entre 90 e 100% da PO máxima, definida no primeiro dia. Em ambos os testes foram mensurados o consumo de oxigênio (VO2), a força aplicada no pedal direito e a cinemática do membro inferior direito dos ciclistas. Se utilizou um modelo bidimensional dos segmentos da coxa, perna e pé, a fim de calcular as forças e momentos resultantes nas articulações do quadril, joelho e tornozelo, por meio da técnica da dinâmica inversa. Foram analisados o somatório absoluto dos momentos articulares resultantes (SMA), o percentual de contribuição de cada articulação para o SMA, a força resultante e a cinemática das articulações do quadril, joelho e tornozelo nos três estágios do teste incremental (75, 90 e 100% da PO máxima) e em quatro instantes do teste de carga constante (10, 40, 70 e 90% do tempo total do teste). No primeiro dia de avaliação (estudo 1) foi observada redução significativa da cadência de pedalada no estágio com carga a 100% da POMáx, comparado aos estágios 75% e 90% da POMáx. Observou-se ainda aumento significativo da contribuição do joelho para o SMA, no estágio a 100% da POMáx, comparado aos estágios 75% e 90% da POMáx, devido ao aumento significativo do momento resultante na articulação do joelho, no estágio a 100% da POMáx, em relação aos estágios com carga a 75 e 90% da POMáx. A força resultante nas três articulações analisadas apresentou aumento significativo ao longo do teste de carga incremental. Para as variáveis cinemáticas, foi observada redução significativa no valor médio do ângulo do tornozelo, assim como aumento significativo na sua amplitude de movimento no estágio 100% da POMáx. Para a articulação do quadril, foi observado aumento no valor médio do ângulo articular, assim como redução na sua amplitude de movimento no estágio com carga a 100% da POMáx. No segundo dia de avaliação (estudo 2) foi observada redução significativa da cadência de pedalada nos instantes 70 e 90% do tempo total de teste, comparados aos instantes 10 e 40% do tempo total. Esta foi acompanhada por redução da contribuição da articulação do tornozelo para o SMA, no instante 90% do tempo total comparado aos instantes 40 e 70% do tempo total do teste, devido ao aumento significativo do momento resultante na articulação do joelho no instante 90% comparado aos instantes 40 e 70% do tempo total e do quadril no instante 90% comparado aos instantes 10, 40 e 70% do tempo total. Se observou aumento na força resultante nas três articulações analisadas, assim como alterações na cinemática das mesmas ao longo do teste (redução do ângulo médio da articulação do tornozelo, com aumento da amplitude de movimento, aumento significativo do ângulo médio das articulações do joelho e do quadril). Os resultados observados indicaram alterações no padrão coordenativo dos ciclistas devido ao processo de instalação da fadiga, estes ocorrendo de forma distinta nos dois protocolos avaliados. As estratégias de controle das articulações durante a pedalada, parecem não ser características inerentes do gesto motor, sendo estas adaptáveis às demandas aumentadas nas articulações devido às alterações na cadência de pedalada e no processo de instalação da fadiga. / Fatigue process has been proposed to change the coordinative pattern; therefore, the analysis of the contribution of each joint to the average absolute joint moment should improve the understanding of the fatigue effects on the coordinative pattern during cycling. The aim of the present study was to compare the contribution of each joint to the average absolute joint moment, as the resultant force and kinematics of the hip, knee, and ankle joints, in an incremental and in a constant workload cycling test to exhaustion. Eleven male road cyclists competing at regional (Texas) and national (United States) levels (age: 31 ± 7 years; maximal oxygen uptake 62.84 ± 4.86 ml.kg-1.min-1; maximal power output 407 ± 37 W) volunteered to participate in the study. Eleven cyclists were submitted to an incremental maximal cycling test with two minutos of workload increment (75, 90 e 100% of POMax, respectively). On the second day, ten cyclists were evaluated in a constant cycling test, in which the workload was set between 90 and 100% of POMax, as defined on the first evaluation day. During both days the oxygen uptake (VO2), right pedal forces and lower limb kinematics were acquired. A bidimensional model of the thigh, leg and foot segments allowed to calculate the resultant forces and moments at the hip, knee and ankle joints by means of inverse dynamics. The average absolute joint moment (SMA), the contribution of each joint to the SMA, the resultant force and kinematics of the hip, knee and ankle joints were analyzed on three stages of incremental cycling test (75, 90 e 100% of POMax), and on four instants of constant workload cycling test (10, 40, 70 and 90% of total time). On the first evaluation day (study 1), a significant decrease of pedaling cadence was observed at the 100% of POMax stage, compared with 75% and 90% of POMax stages. There was also a significant increase of knee joint contribution to the SMA at 100% of POMax stage, compared with 75% and 90% of POMax stages, due to a significant increase of knee joint absolute moment at 100% of POMax stage, compared with 75% and 90% of POMax stages. The resultant joint force on the three joints have significantly increased, while joint kinematics has changed with the increase of workload (reduced mean ankle angle, with increased ankle range of motion) For hip joint, there was a significant increase of mean angle, with reduced range of motion at 100% of POMax. On the second evaluation day (study 2) a significant reduction of pedaling cadence was observed at the 70% and 90% of total time, compared with 10% and 40% of total time. This result was followed by a significant reduction of the ankle joint contribution to the SMA at the 90% of total time, compared with 40% and 70% of total time, due to a significant increase of knee resultant joint moment on the 90% of total time, compared with 40% and 70% of total time, and for the hip resultant joint moment at the 90% of total time, compared with 10, 40, and 70% of total time. There was also a significant increase of the resultant joint force and a change on kinematics of the three joints throught the test (reduced mean ankle angle, with increased range of motion, and a significant increase of the mean value of knee and hip angles). The results indicated that the coordinative pattern changed with fatigue, with discrete effects in each cycling test. The strategies of joint control during cycling should not be an innate robust motor behavior, but these strategies should be adaptable to higher demands on the joints, as significant changes on pedaling cadence and fatigue.

Page generated in 0.0745 seconds