Spelling suggestions: "subject:"próteses dentária"" "subject:"próteses dentários""
1 |
Análise bioquímica das alterações salivares relacionadas à adaptação funcional de pacientes usuários de próteses totaisBreseghelo, Maria de Lourdes 18 December 2014 (has links)
Submitted by Cláudia Bueno (claudiamoura18@gmail.com) on 2016-02-01T16:49:21Z
No. of bitstreams: 2
Tese - Maria de Lourdes Breseghelo - 2014.pdf: 1257515 bytes, checksum: 30aeeb0256b3eb5c586b4380a75aaf0c (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2016-02-02T06:56:44Z (GMT) No. of bitstreams: 2
Tese - Maria de Lourdes Breseghelo - 2014.pdf: 1257515 bytes, checksum: 30aeeb0256b3eb5c586b4380a75aaf0c (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2016-02-02T06:56:44Z (GMT). No. of bitstreams: 2
Tese - Maria de Lourdes Breseghelo - 2014.pdf: 1257515 bytes, checksum: 30aeeb0256b3eb5c586b4380a75aaf0c (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5)
Previous issue date: 2014-12-18 / Complete dentures represent the main treatment for total edentulism in the overall population. However this type of treatment can lead to the onset of physiological and functional alterations during the adaptative period after the installation of the denture. The objective of this work was to evaluate modifications in biochemical parameters (nitric oxide and cortisol levels) in complete denture user's saliva and verify its association with clinical parameters like levels of functional adaptation, trauma, salivary flux, and viscosity. Nineteen totally toothless patients in need of installation or substitution of dentures were selected and evaluated during the installation, adaptation and in the post-adaptation period. The protocol for making the complete dentures followed clinical and laboratory procedures. The nitric oxide concentration dosage was performed via the Griess reaction, where the measurement taken is the nitrite concentration, since nitric oxide is very unstable and rapidly transforms into nitrite. The points for construction of the calibration curve were made in triplicate using the nitrite concentration, which varied from 5 to 150 μM, wherein for each analyzed plate a new curve was built. The salivary cortisol concentration was performed using Salimetrics No. 1-3002 (single) enzymatic kit. A descriptive statistical analysis was done for representation of summary measures of the variables measured. Non-parametric tests (Friedman, Wilcoxon, Mann-Whitney and Kruskal-Wallis tests) were used for group comparison. Salivary nitric oxide levels were quantified for each evaluation period and correlated between themselves, showing statistically significant differences among them. The adaptative periods showed a decrease in nitric oxide levels between installation and post-installation. There were no significant differences in correlations between salivary nitric oxide concentrations and levels of functional adaptation, trauma, salivary flux and viscosity. The salivary cortisol levels were evaluated at two periods, in the post-adaptative and after some months of denture use, showing great variation at the first period and stabilization at the second. There was no significant difference when correlated to the levels of functional adaptation and trauma. It was concluded that the prosthetic treatment caused alterations in salivary nitric oxide and cortisol levels during adaptation to dentures however these levels came back to normal after that period. / Próteses totais convencionais representam o principal tratamento para o edentulismo total na população em geral. Entretanto este tratamento pode levar ao aparecimento de alterações fisiológicas e funcionais transitórias durante o período adaptativo após a instalação das próteses. O objetivo deste trabalho foi avaliar modificações em parâmetros bioquímicos (níveis de óxido nítrico e cortisol) na saliva de usuários de próteses e verificar sua associação com parâmetros clínicos como os níveis de adaptação funcional, traumatismos, fluxo salivar e viscosidade. Foram selecionados 19 pacientes desdentados totais com necessidade de instalação ou substituição de próteses os quais foram avaliados na instalação, durante a adaptação e no período pós-adaptativo. O protocolo para confecção de próteses totais seguiu os procedimentos clínicos e laboratoriais. A dosagem da concentração de óxido nítrico foi feita por meio da reação de Griess onde a medida realizada é a concentração de nitrito uma vez que o óxido nítrico é muito instável e logo se transforma em nitrito. Os pontos para a construção da curva de calibração foram feitos em triplicata utilizando-se concentrações de nitrito que variaram de 5 a 150 μM sendo que para cada placa analisada uma nova curva foi construída. A dosagem da concentração de cortisol salivar foi feita utilizando-se o kit enzimático No. 1-3002 (single) Salimetrics. Foi realizada análise estatística descritiva para representação das medidas de resumos das variáveis mensuradas. Testes não paramétricos (Testes de Friedman, Wilcoxon, Mann-Whitney e Kruskal-Wallis) foram utilizados para comparação entre grupos. Os níveis de óxido nítrico salivar foram quantificados para cada um dos períodos de avaliação e correlacionados entre si, mostrando diferenças estatisticamente significativas entre eles. Os períodos adaptativos mostraram uma queda nos níveis de óxido nítrico em relação à instalação e à pós-instalação. Não houve diferenças significativas nas correlações entre as concentrações de óxido nítrico salivar e os níveis de adaptação funcional, traumatismo, fluxo salivar e viscosidade. Os níveis de cortisol salivar foram avaliados em dois períodos, no pós-adaptativo e depois de alguns meses de uso da prótese, mostrando grande variação no primeiro e estabilização no segundo. Não houve diferença significativa quando correlacionado com níveis de adaptação funcional e traumatismos. Concluiu-se que o tratamento protético provocou alterações nos níveis de óxido nítrico e cortisol salivares durante a adaptação às próteses porem estes níveis voltaram aos normais após este período.
|
2 |
Desenvolvimento de ligas à base de Ni-Cr para prótese dentária / Development of the Ni-Cr Base Alloys for Dental ProsthesesLuciano Braga Alkmin 19 May 2011 (has links)
O presente trabalho visou desenvolver ligas à base de Níquel-Cromo para prótese dentária, que confiram as melhores características metalúrgicas e químicas para posterior produção e aplicação. Para isto foram adquiridas amostras de ligas comerciais de 8 fabricantes. Os materiais foram caracterizados em termos de composição química, propriedades mecânicas, caracterização microestrutural, temperatura de fusão, coeficiente de expansão térmica, corrosão e biocompatibilidade. Para isto, utilizou-se as fluorescência de raios X (XRF-WDS), ICP-OES, ensaios de tração, ensaios de dureza, ensaios de corrosão, avaliação de citotoxicidade, microscopia eletrônica de varredura (MEV), microanálise eletrônica (EDS), difratometria de Raios X (DRX), análise térmica diferencial (DTA), dilatometria e avaliação de fluidez. A maioria dos resultados composicionais não condiz com as composições fornecidas pelos fabricantes. Os resultados mostraram claramente a presença de um eutético típico formado pelas fases Niss e NiBe nas ligas contendo Be, que pode ser considerado uma \"impressão digital\" da presença deste elemento nestas ligas. É possível verificar a formação de intermetálicos na região interdendritica para as ligas isentas de Be, sendo identificado um siliceto (Nb6Ni16Si7) em uma das ligas, que possui temperatura de inicio de fusão inferior ao eutético Niss e NiBe das ligas com Be. De uma forma geral, os resultados dos ensaios de dureza mostraram valores superiores de dureza para as ligas com Be. Foi escolhida uma das ligas comerciais para a reprodução em escala laboratorial (LAB) e industrial (IND). Estas ligas produzidas apresentaram as mesmas características microestruturais, químicas e físicas da liga comercial. Nos ensaios de fluidez, a liga LAB apresentou o mesmo comportamento da liga comercial. A liga IND apresentou limite de escoamento e módulo de elasticidade de ?e0,02%= 810MPa e E= 200 GPa, respectivamente. Os ensaios de corrosão mostraram comportamento passivo tanto para a liga comercial quanto para a liga IND em saliva artificial e enxaguante bucal. O ensaio de citotoxicidade da liga IND indicou comportamento não citotóxico em controle negativo (Chapa de Ti). Os resultados obtidos com a liga IND indicam a possibilidade de fabricação desta liga Ni-Cr para próteses dentárias em escala industrial. / This study aimed to develop nickel-chromium base alloys for dental prostheses with the best characteristics for subsequent production and application. Samples were acquired from eight manufacturers of commercial alloys. The materials were characterized in terms of chemical composition, mechanical properties, microstructure, melting temperature, coefficient of thermal expansion, corrosion and biocompatibility. For this, we have used X-ray fluorescence (XRF-WDS), ICP-OES, tensile tests, hardness testing, corrosion testing, evaluation of cytotoxicity, scanning electron microscopy (SEM), electron probe microanalysis (EDS) , X-ray diffraction (XRD), differential thermal analysis (DTA), dilatometry and evaluation of fluidity. Most of the chemical compositional determined in this study were not consistent with the compositions provided by the manufacturers. The results clearly showed the presence of a typical eutectic microstructure formed by Niss and NiBe in alloys containing Be, which can be considered a \"fingerprint\" of the presence of this element in these alloys. It was possible to verify the formation of intermetallics in the interdendritic region of the Be-free alloys. In one of the alloys this intermetallic was identified as (Nb6Ni16Si7), this alloy presenting a initial melting temperature below the eutectic melting of the Niss+NiB eutectic. Overall, the results of hardness tests showed superior hardness for alloys with Be. One of the commercial alloys was chosen for reproduction in laboratory (LAB) and industrial (IND) scales. The alloys produced showed the same microstructural characteristics, chemical and physical characteristics of the commercial alloy. In the fluidity tests, the LAB alloy showed the same behavior of the commercial alloy. The IND alloy presented yield strength and modulus of elasticity ?e0, 02% = 810MPa, E = 200 MPa, respectively. The corrosion tests showed passive behavior for both commercial and IND alloy in artificial saliva and mouthwash solutions. The cytotoxicity assay indicated that the IND alloy is not cytotoxic in the negative control (Ti plate). The results obtained with the IND alloy indicate the possibility of fabrication this alloy for dental prosthesis on an industrial scale.
|
3 |
Desenvolvimento de ligas à base de Ni-Cr para prótese dentária / Development of the Ni-Cr Base Alloys for Dental ProsthesesAlkmin, Luciano Braga 19 May 2011 (has links)
O presente trabalho visou desenvolver ligas à base de Níquel-Cromo para prótese dentária, que confiram as melhores características metalúrgicas e químicas para posterior produção e aplicação. Para isto foram adquiridas amostras de ligas comerciais de 8 fabricantes. Os materiais foram caracterizados em termos de composição química, propriedades mecânicas, caracterização microestrutural, temperatura de fusão, coeficiente de expansão térmica, corrosão e biocompatibilidade. Para isto, utilizou-se as fluorescência de raios X (XRF-WDS), ICP-OES, ensaios de tração, ensaios de dureza, ensaios de corrosão, avaliação de citotoxicidade, microscopia eletrônica de varredura (MEV), microanálise eletrônica (EDS), difratometria de Raios X (DRX), análise térmica diferencial (DTA), dilatometria e avaliação de fluidez. A maioria dos resultados composicionais não condiz com as composições fornecidas pelos fabricantes. Os resultados mostraram claramente a presença de um eutético típico formado pelas fases Niss e NiBe nas ligas contendo Be, que pode ser considerado uma \"impressão digital\" da presença deste elemento nestas ligas. É possível verificar a formação de intermetálicos na região interdendritica para as ligas isentas de Be, sendo identificado um siliceto (Nb6Ni16Si7) em uma das ligas, que possui temperatura de inicio de fusão inferior ao eutético Niss e NiBe das ligas com Be. De uma forma geral, os resultados dos ensaios de dureza mostraram valores superiores de dureza para as ligas com Be. Foi escolhida uma das ligas comerciais para a reprodução em escala laboratorial (LAB) e industrial (IND). Estas ligas produzidas apresentaram as mesmas características microestruturais, químicas e físicas da liga comercial. Nos ensaios de fluidez, a liga LAB apresentou o mesmo comportamento da liga comercial. A liga IND apresentou limite de escoamento e módulo de elasticidade de ?e0,02%= 810MPa e E= 200 GPa, respectivamente. Os ensaios de corrosão mostraram comportamento passivo tanto para a liga comercial quanto para a liga IND em saliva artificial e enxaguante bucal. O ensaio de citotoxicidade da liga IND indicou comportamento não citotóxico em controle negativo (Chapa de Ti). Os resultados obtidos com a liga IND indicam a possibilidade de fabricação desta liga Ni-Cr para próteses dentárias em escala industrial. / This study aimed to develop nickel-chromium base alloys for dental prostheses with the best characteristics for subsequent production and application. Samples were acquired from eight manufacturers of commercial alloys. The materials were characterized in terms of chemical composition, mechanical properties, microstructure, melting temperature, coefficient of thermal expansion, corrosion and biocompatibility. For this, we have used X-ray fluorescence (XRF-WDS), ICP-OES, tensile tests, hardness testing, corrosion testing, evaluation of cytotoxicity, scanning electron microscopy (SEM), electron probe microanalysis (EDS) , X-ray diffraction (XRD), differential thermal analysis (DTA), dilatometry and evaluation of fluidity. Most of the chemical compositional determined in this study were not consistent with the compositions provided by the manufacturers. The results clearly showed the presence of a typical eutectic microstructure formed by Niss and NiBe in alloys containing Be, which can be considered a \"fingerprint\" of the presence of this element in these alloys. It was possible to verify the formation of intermetallics in the interdendritic region of the Be-free alloys. In one of the alloys this intermetallic was identified as (Nb6Ni16Si7), this alloy presenting a initial melting temperature below the eutectic melting of the Niss+NiB eutectic. Overall, the results of hardness tests showed superior hardness for alloys with Be. One of the commercial alloys was chosen for reproduction in laboratory (LAB) and industrial (IND) scales. The alloys produced showed the same microstructural characteristics, chemical and physical characteristics of the commercial alloy. In the fluidity tests, the LAB alloy showed the same behavior of the commercial alloy. The IND alloy presented yield strength and modulus of elasticity ?e0, 02% = 810MPa, E = 200 MPa, respectively. The corrosion tests showed passive behavior for both commercial and IND alloy in artificial saliva and mouthwash solutions. The cytotoxicity assay indicated that the IND alloy is not cytotoxic in the negative control (Ti plate). The results obtained with the IND alloy indicate the possibility of fabrication this alloy for dental prosthesis on an industrial scale.
|
4 |
Influência do orifício de acesso ao parafuso do intermediário do implante na resistência de infraestruturas de zircônia estabilizadas por ítrio e dissilicato de lítio / Influence the access hole to screw the implant in the intermediate resitance of infrastructure zirconia stabilized by yttrium and lithium disilicateWilliam Bogard de Souza e Silva 01 June 2014 (has links)
Hipótese do trabalho: Avaliar a presença de um orifício de acesso ao parafuso do intermediário do implante em infra-estruturas cimentadas sobre o pilar de titânio. Objetivo: O presente estudo visou comparar resistência a compressão de infra-estruturas em zircônia estabilizada por ítrio e em dissilicato de lítio cimentadas sobre pilar em titânio, com e sem acesso ao parafuso. Método: Foram confeccionados quarenta corpos-de-prova compostos por análogos de implantes hexágono externo de plataforma 4,1mm, intermediários de titânio pré-fabricado para próteses cimentadas e infra-estruturas para coroas totais. Os corpos-de-prova foram divididos em quatro grupos experimentais, sendo vinte, em cerâmica de zircônia estabilizada por ítrio(G1 e G2) e vinte em cerâmica de dissilicato de lítio(G3 e G4), todas confeccionadas com a mesma anatomia, ambas para próteses cimentadas sobre implante. Das vinte infra-estruturas de cada tipo de cerâmica, dez foram infra-estruturas convencionais para coroas cimentadas, constituindo o grupo controle e dez apresentavam um orifício de acesso ao parafuso, transpassando a cerâmica, constituindo o grupo experimental. As cimentações foram efetuadas com agente de fixação RelyX U200, de acordo com as especificações do fabricante, e o grupo experimental (com acesso ao parafuso) teve o orifício de acesso ao canal restaurado com resina composta foto ativada Z350 Filtek Supreme XT. Os corpos-de-prova foram submetidos a teste de compressão com velocidade de 0,5mm/minuto em máquina de ensaio universal. Resultados: Não foram encontradas diferenças estatísticas significativas entre infra-estruturas de cerâmicas convencionais e as infra-estruturas confeccionadas com orifício de acesso oclusal(G2 1.675 N/cm., G3 1.931 N/cm e G4 1.447 N/cm), exceto as infra-estruturas convencionais de zircônia estabilizada por ítrio que se apresentou superior aos demais(G1 3.372 N/cm). Com base nos resultados todas as modalidades de infra-estruturas testadas são viáveis para o uso clínico. / Hypothesis of work: To evaluate the presence of an access hole to screw the intermediate cemented implant in infrastructure over the titanium abutment. Objective: This study aimed to compare the compressive strength of infrastructure in yttrium stabilized zirconia and lithium disilicate cemented to abutment in titanium, with and without access to the screw. Method: Forty bodies-specimens consisting of similar external hex implants platform 4.1mm, intermediate titanium prefabricated for cemented prostheses and infrastructures for crowns were fabricated. The bodies-specimens were divided into four experimental groups, twenty, ceramic yttrium stabilized zirconia (G1 and G2) and twenty in ceramic lithium disilicate (G3 and G4), all made with the same anatomy, both for cemented prostheses on implants. Infrastructure of twenty of each type of tile ten were conventional infrastructure for cemented crowns, constituting the control group and ten had an access hole to the screw, trespassing ceramics, constituting the experimental group. The cementation were performed with RelyX U200 fixing agent, according to the manufacturers specifications, and the experimental group (with access to the screw) had the access hole channel restored with composite resin Z350 photo activated Filtek Supreme XT. The bodies-specimens were subjected to compression test speed of 0.5 mm / min in a universal testing machine. Results: No statistically significant differences between conventional ceramic infrastructure and infrastructure made with port access were found occlusal (G2 1675 N / cm, G3 1931 N / cm and G4 1447 N / cm.) Except conventional infrastructure stabilized zirconia yttrium who introduced himself superior to the others (G1 3300 N / cm). Based on the results of all modalities tested infrastructure are feasible for clinical use.
|
5 |
A média complexidade no quadro da Política Nacional de Saúde Bucal: uma abordagem do seu processo de desenvolvimento em uma perspectiva regional / The medium complexity in the National Oral Health Policy: an approach to the development process under a regional perspectiveRenata Ferraiolo Peixoto Fortuna 26 April 2011 (has links)
Esta tese tem por objeto o processo de regionalização das ações de média complexidade e da oferta de próteses dentárias no âmbito da Política Nacional de Saúde Bucal (PNSB). Foram realizadas duas pesquisas fundamentais para o entendimento desse processo: a primeira esteve voltada para o levantamento da descrição da oferta de ações especializadas e de próteses dentárias nos Planos Diretores de Regionalização (PDR) nas 27 unidades federadas do país. A segunda pesquisa verificou a cobertura por Equipes de Saúde Bucal (ESBs) na Estratégia de Saúde da Família (ESF) e a distribuição dos 844 Centros de Especialidades Odontológicas (CEOs) e dos 526 Laboratórios Regionais de Próteses Dentárias (LRPDs) implantados até setembro de 2010 nas regiões de saúde do Brasil dos 27 estados da federação. Essas pesquisas permitiram concluir que: os PDRs, na grande maioria dos estados brasileiros, não contribuíram para a organização regionalizada da distribuição de CEOs e LRPDs no Brasil. A cobertura por Equipes de Saúde Bucal é heterogênea, com predominância da Região Nordeste e dos municípios de pequeno porte, em detrimento das capitais e dos estados das regiões Sul e Sudeste. No tocante à distribuição das unidades CEO e LRPD pelas regiões de saúde, a pesquisa mostrou que os critérios normativos para a seleção dos municípios a sediarem essas unidades vêm sendo cumpridos de forma precária na maior parte do país. Além disso, a distribuição dessas unidades não apresenta coerência com os princípios da regionalização prevista pelo Pacto de Gestão do SUS. / This thesis analyzes the process of regionalization of medium complexity actions and the supply of dental prostheses in the National Oral Health Policy (PNSB). Two main surveys were made for the understanding of this process: the first was aimed at describing the offer of specialized actions and dental prostheses according to the Regionalization Master Plans (PDR) in 27 federal units of the country. The second study examined the coverage by Oral Health Teams (ESBs) in the Family Health Strategy (ESF) and the distribution of 844 Specialized Dental Centers (CEOs) of 526 Regional Laboratories of Dental Prostheses (LRPDs) deployed by September 2010 in the Brazilian health regions in 27 states. These surveys showed that: the PDRs, in the vast majority of Brazilian states, have not contributed to the organization of regionalized distribution of CEOs and LRPDs in Brazil. Coverage by ESBs is heterogeneous, mostly in the Northeastern Region and in small towns, at the expense of the capital and the Southern and Southeastern states. Regarding the distribution of CEO and LRPD units by health regions, the survey showed that the normative criteria for the selection of municipalities to settle these units have been precariously completed in most of the country. Moreover, the distribution of those units is not consistent with the regionalization principles provided by the SUS Management Pact.
|
6 |
A média complexidade no quadro da Política Nacional de Saúde Bucal: uma abordagem do seu processo de desenvolvimento em uma perspectiva regional / The medium complexity in the National Oral Health Policy: an approach to the development process under a regional perspectiveRenata Ferraiolo Peixoto Fortuna 26 April 2011 (has links)
Esta tese tem por objeto o processo de regionalização das ações de média complexidade e da oferta de próteses dentárias no âmbito da Política Nacional de Saúde Bucal (PNSB). Foram realizadas duas pesquisas fundamentais para o entendimento desse processo: a primeira esteve voltada para o levantamento da descrição da oferta de ações especializadas e de próteses dentárias nos Planos Diretores de Regionalização (PDR) nas 27 unidades federadas do país. A segunda pesquisa verificou a cobertura por Equipes de Saúde Bucal (ESBs) na Estratégia de Saúde da Família (ESF) e a distribuição dos 844 Centros de Especialidades Odontológicas (CEOs) e dos 526 Laboratórios Regionais de Próteses Dentárias (LRPDs) implantados até setembro de 2010 nas regiões de saúde do Brasil dos 27 estados da federação. Essas pesquisas permitiram concluir que: os PDRs, na grande maioria dos estados brasileiros, não contribuíram para a organização regionalizada da distribuição de CEOs e LRPDs no Brasil. A cobertura por Equipes de Saúde Bucal é heterogênea, com predominância da Região Nordeste e dos municípios de pequeno porte, em detrimento das capitais e dos estados das regiões Sul e Sudeste. No tocante à distribuição das unidades CEO e LRPD pelas regiões de saúde, a pesquisa mostrou que os critérios normativos para a seleção dos municípios a sediarem essas unidades vêm sendo cumpridos de forma precária na maior parte do país. Além disso, a distribuição dessas unidades não apresenta coerência com os princípios da regionalização prevista pelo Pacto de Gestão do SUS. / This thesis analyzes the process of regionalization of medium complexity actions and the supply of dental prostheses in the National Oral Health Policy (PNSB). Two main surveys were made for the understanding of this process: the first was aimed at describing the offer of specialized actions and dental prostheses according to the Regionalization Master Plans (PDR) in 27 federal units of the country. The second study examined the coverage by Oral Health Teams (ESBs) in the Family Health Strategy (ESF) and the distribution of 844 Specialized Dental Centers (CEOs) of 526 Regional Laboratories of Dental Prostheses (LRPDs) deployed by September 2010 in the Brazilian health regions in 27 states. These surveys showed that: the PDRs, in the vast majority of Brazilian states, have not contributed to the organization of regionalized distribution of CEOs and LRPDs in Brazil. Coverage by ESBs is heterogeneous, mostly in the Northeastern Region and in small towns, at the expense of the capital and the Southern and Southeastern states. Regarding the distribution of CEO and LRPD units by health regions, the survey showed that the normative criteria for the selection of municipalities to settle these units have been precariously completed in most of the country. Moreover, the distribution of those units is not consistent with the regionalization principles provided by the SUS Management Pact.
|
Page generated in 0.0797 seconds