• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 16
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 16
  • 16
  • 16
  • 8
  • 8
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Acurácia e precisão na formulação não linear de ração para frangos de corte: avanço e otimização de resultados

Gonçalves, Camila Angelica [UNESP] 08 February 2013 (has links) (PDF)
Made available in DSpace on 2015-04-09T12:28:19Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-02-08Bitstream added on 2015-04-09T12:47:41Z : No. of bitstreams: 1 000814534.pdf: 1033654 bytes, checksum: 6e36782a784b174f00b2f53aa141d451 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (Capes) / The poultry industry has sought to optimize animal production. For this reason, the mathematical modeling is an essential tool to achieve greater control and production planning, appropriate to the different feeding conditions, market and economic interests. This study aimed to obtain mathematical models capable of predicting the responses of broiler performance due to changes in levels of energy density, according to the phase and sex, as base to a system of nonlinear feed formulation. Therefore, two experiments were conducted simultaneously, for 240 broiler females and 240 males. The birds were distributed in a completely randomized design with six energy levels (2,800; 2,900; 3,000; 3,100; 3,200 and 3,300 kcal ME/kg, maintaining the relationship between energy and other nutrients) and four replicates of ten birds, allocated to floor pens. Data on body weight, feed intake, energy consumption, feed conversion, carcass weight and abdominal fat were analyzed by response surface methodology. Feed intake and body weight were used to determine rates of gain that maximize economic return, according to the energy density, the market prices of ingredients and kilogram of broilers. It was concluded that the concept of nonlinear formulation seems more appropriate to meet the concept of precision nutrition for broilers, since the requirements of all nutrients are automatically adjusted by the mathematical model related to energy content estimated, according to the nutritional recommendations for different ages and stages of broilers, according to the program PPFR / FAPESP: 2009/09500-0
12

Acurácia e precisão na formulação não linear de ração para frangos de corte: avanço e otimização de resultados /

Gonçalves, Camila Angelica. January 2013 (has links)
Resumo:A avicultura de corte tem buscado a otimização da produção animal. Por esta razão, a modelagem matemática representa uma ferramenta imprescindível para se obter um maior controle e planejamento produtivo, adequado às diferentes condições de alimentação, do mercado e interesses econômicos. Assim, este trabalho teve a finalidade de obter modelos matemáticos, capazes de estimar as repostas do desempenho de frangos de corte em razão das mudanças da densidade energética da dieta, segundo a fase de criação e o sexo, como base de um sistema de formulação de rações não linear. Para tanto, foram conduzidos simultaneamente dois experimentos, para 240 frangos de corte fêmeas e 240 machos. As aves foram distribuídas em delineamento inteiramente casualizado com seis níveis de energia metabolizável (2.800; 2.900; 3.000; 3.100; 3.200 e 3.300 kcal/kg, mantendo-se a relação entre os demais nutrientes) e quatro repetições de dez aves, sendo alojadas em piso. Os dados de peso corporal, consumo de ração, consumo de energia, conversão alimentar, peso da carcaça e da gordura cavitária foram analisados segundo a metodologia de superfície de resposta. O consumo de ração e o peso corporal foram utilizados para se determinar as taxas de ganho que maximizam o retorno econômico, de acordo com a densidade energética, os preços de mercado dos ingredientes e do kg do frango. Concluiu-se que o princípio de formulação não linear mostra-se mais apropriado para atender ao conceito da nutrição de precisão para frangos de corte, uma vez que, as exigências de todos os nutrientes são automaticamente ajustadas pelo modelo matemático, relacionados ao teor energético estimado, conforme as recomendações nutricionais distintas para fases e idades de frangos de corte, segundo o programa PPFR / Abstract:The poultry industry has sought to optimize animal production. For this reason, the mathematical modeling is an essential tool to achieve greater control and production planning, appropriate to the different feeding conditions, market and economic interests. This study aimed to obtain mathematical models capable of predicting the responses of broiler performance due to changes in levels of energy density, according to the phase and sex, as base to a system of nonlinear feed formulation. Therefore, two experiments were conducted simultaneously, for 240 broiler females and 240 males. The birds were distributed in a completely randomized design with six energy levels (2,800; 2,900; 3,000; 3,100; 3,200 and 3,300 kcal ME/kg, maintaining the relationship between energy and other nutrients) and four replicates of ten birds, allocated to floor pens. Data on body weight, feed intake, energy consumption, feed conversion, carcass weight and abdominal fat were analyzed by response surface methodology. Feed intake and body weight were used to determine rates of gain that maximize economic return, according to the energy density, the market prices of ingredients and kilogram of broilers. It was concluded that the concept of nonlinear formulation seems more appropriate to meet the concept of precision nutrition for broilers, since the requirements of all nutrients are automatically adjusted by the mathematical model related to energy content estimated, according to the nutritional recommendations for different ages and stages of broilers, according to the program PPFR / Orientador: Manoel Garcia Neto / Banca: Marcos Franke Pinto / Banca: Douglas Emygdio de Faria / Mestre
13

Efeito da fotopolimerização complementar em resinas para impressoras por estereolitografia em suas propriedades mecânicas e diferentes designs de impressão na precisão de modelos odontológicos /

Almeida, Layene Figueiredo. January 2020 (has links)
Orientador: Lidia Parsekian Martins / Resumo: OBJETIVO: Identificar e quantificar diferenças nas propriedades mecânicas de quatro resinas para impressão por estereolitografia em função do tempo de exposição à luz ultravioleta pós impressão e quantificar diferenças dimensionais em modelos odontológicos produzidos por estereolitografia em relação à inserção de barra estabilizadora transversal na região posterior, à orientação de impressão, vertical ou horizontal, tipo de modelo, oco ou maciço, e pós cura com luz ultravioleta ou não, por meio de medições lineares. MÉTODOS: 140 espécimes foram impressos em impressoras 3D do tipo SLA (estereolitografia a laser) e DLP (estereolitografia por processamento digital de luz) para cada teste mecânico realizado e foram divididos em 28 grupos, de acordo com a resina (4 tipos: Blue, Gray, Surgical Guide, Standard) e o tempo de pós cura com luz ultravioleta (7 tempos: 0, 5, 10, 15, 30, 60 e 120 minutos). Foram realizados os testes de microdureza Vickers, tração diametral e flexão três pontos. Os dados obtidos foram submetidos a uma ANOVA de dois níveis e ao pós teste de Tukey. Para a avaliação das alterações dimensionais de modelos odontológicos foram realizados dois experimentos distintos. No primeiro, 56 modelos odontológicos do arco maxilar em formato de ferradura foram impressos na impressora MoonRay S100 (SprintRay) com a resina Gray (SprintRay), variando a orientação de impressão, a presença de barra e o processo de pós cura. Depois de impressos foram escaneados em escâner de mesa... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: OBJECTIVE: To identify and quantify differences in the mechanical properties of four resins for stereolithography printing varying time of exposure to ultraviolet light and to quantify dimensional differences in dental models produced by stereolithography regarding the insertion of a transverse stabilizer bar in the posterior region, the printing orientation, vertical or horizontal, model type, hollow or solid, and post-cure with ultraviolet light or not, by means of linear measurements. METHODS: 140 specimens were printed by SLA (laser stereolithography) and DLP (digital light processing stereolithography) printers for each mechanical test performed and were divided into 28 groups, according to the resin (4 types: Blue, Gray, Surgical Guide, Standard) and the post-cure time with ultraviolet light (7 times: 0, 5, 10, 15, 30, 60 and 120 minutes). Vickers microhardness tests, diametrical traction and three point flexion were performed. The data obtained were submitted to a two-way ANOVA and the Tukey post-test. To evaluate the dimensional changes of dental models, two different experiments were carried out. In the first, 56 horseshoe-shaped dental models of a maxillary arch were printed on the MoonRay S100 (SprintRay) with Gray resin (SprintRay), varying the printing orientation, the presence of a bar and the post-curing process. After printing, they were scanned on a R700 table scanner (3Shape) and then measurements between canines, first and second premolars and molars and ar... (Complete abstract click electronic access below) / Doutor
14

Análise comparativa da acurácia de modelos impressos, obtidos a partir de escaneamento intra-oral / Comparative analysis of the accuracy of printed casts, obtained from intraoral scanning

Igai, Fernando 28 November 2018 (has links)
A confecção de trabalhos protéticos em um fluxo digital é possível a partir do escaneamento intra-oral e confecção da Prótese via CAD/CAM. A tecnologia atual de impressão 3D permite a obtenção de um modelo impresso, para a realização de determinados procedimentos. Entretanto, é necessário analisar e comparar estes modelos com os modelos de gesso, uma vez que existe uma diferença significativa na forma de obtenção, assim como, nos custos de cada tipo de modelo. O presente estudo teve como objetivo realizar uma análise da acurácia entre modelos impressos, obtidos por meio de escaneamento intra-oral e impressão 3D, e modelos de gesso obtidos pelo método de moldagem convencional. Foi utilizado um manequim odontológico como modelo mestre e foram confeccionados dez modelos de gesso (n= 10), pela técnica de moldagem da dupla impressão com silicone de adição. Foram utilizados dois tipos de escâneres intra-orais e dois tipos de impressoras 3D, que formaram quatro grupos experimentais com dez modelos por grupo (n= 10). Os modelos físicos de gesso e impressos foram comparados com o modelo mestre por meio de análises de medições lineares em seis sítios de medições, com o uso de uma máquina de medição por imagem (Quick Scope, Mitutoyo®). A análise dos modelos impressos incluiu as possíveis interações entre os fatores principais tipo de impressora, tipo de escâner e sítios de medições. Os resultados mostraram que em relação ao modelo mestre, no geral, as discrepâncias dos modelos de gesso foram menores que as discrepâncias dos modelos impressos. A análise das interações dos fatores principais indicou que o tipo de impressora exerceu a maior influência na acurácia dos modelos impressos, seguido do fator sítio de medição e tipo de escâner. Pôde-se concluir que os modelos de gesso apresentaram uma acurácia superior quando comparados com os modelos impressos. O acabamento superficial dos modelos impressos exerceu influência na sua acurácia. / The preparation of prosthetic restoration in a digital flow is possible using intraoral scanning and confection of the prosthesis via CAD/CAM. The current 3D printing technology allows the making of a printed cast, for performing certain laboratory procedures. However, it is necessary to analyze and compare these casts with the gypsum casts, since there is a significant difference in the form of obtaining, as well as, in the costs of each type of cast. The objective of the present study was to perform a comparative study of the accuracy of printed casts, obtained through intraoral scanning and 3D printing, and gypsum casts, obtained through the conventional impression. A dental mannequin was used as the master model and ten gypsum casts (n=10) were obtained, using double impression technique with polyvinyl siloxane. Two types of intraoral scanners and two types of 3D printers were used, which formed four experimental groups with ten models per group (n=10). The real gypsum and printed casts were compared to the master model by linear measurements in six sites, using an image-measuring machine (Quick Scope, Mitutoyo®). The analysis of the printed models included possible interactions between the factors type of printer, type of scanner and measurement sites. The results showed that, in relation to the master model, in general, the discrepancies of the gypsum casts were smaller than the discrepancies of the printed casts. The interactions of the factors analysis indicated that the type of printer exerted the greatest influence on the accuracy of the printed casts, followed by the site measurement and type of scanner. It was conclude that the gypsum casts presented superior accuracy when compared to the printed casts. The surface finish of the printed casts exerted influence in its accuracy.
15

Avaliação da alteração dimensional de quatro siliconas por condensação através da medição tridimensional por coordenadas / Evaluation of dimensional change of four condensation silicones by three dimensional coordinate measuring

Monteiro, Jaiane Bandoli 30 April 2015 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2015-12-03T16:47:38Z No. of bitstreams: 1 jaianebandolimonteiro.pdf: 2039791 bytes, checksum: c3f28c1a95fdef73d0cc0190a9dfa169 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2015-12-03T21:29:38Z (GMT) No. of bitstreams: 1 jaianebandolimonteiro.pdf: 2039791 bytes, checksum: c3f28c1a95fdef73d0cc0190a9dfa169 (MD5) / Made available in DSpace on 2015-12-03T21:29:38Z (GMT). No. of bitstreams: 1 jaianebandolimonteiro.pdf: 2039791 bytes, checksum: c3f28c1a95fdef73d0cc0190a9dfa169 (MD5) Previous issue date: 2015-04-30 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O objetivo foi avaliar a alteração dimensional dos moldes de silicona por condensação imediatamente, 30min, 1h e 7 dias após a moldagem, com o auxílio da máquina de medição tridimensional por coordenadas. Os grupos foram divididos em: G1: Speedex Putty/Speedex Light Body (Coltene/Vigodent AS Indústria e Comércio), G2: Optosil P Plus/Xantopren L Blue (Heraeus Kulzer GmbH), G3: Zetaplus Putty/Oranwash L (Zhermack SpA) e G4: Precise SX (Dentsply Indústria e Comércio Ltda). Para a obtenção das 80 medições dos 4 materiais (n=20), foi usado um dispositivo composto por uma moldeira perfurada e uma outra parte com 3 edentações pré-estabelecidas. Para a avaliação dimensional, a máquina Crysta-Plus M 574 (Mitutoyo) realizou cada medida 3 vezes nos tempos estabelecidos e obteve-se a média aritmética. A média final das 4 distâncias I, II, III e IV do dispositivo edentado foi novamente aplicada. A análise estatística foi realizada com o teste de Kolmogorov-Smirnov que rejeitou a hipótese nula de distribuição assimétrica. Posteriormente, foi feita a ANOVA para comparar os 4 materiais simultaneamente e o teste paramétrico t de Student para comparar os materiais 2 a 2. O nível de significância global foi de p≤0,05. A maior contração linear foi observada na Speedex, mas não foi significante (p=0,08). A Zetaplus Putty/Oranwash L parece ser a mais estável (p=0,99), mas não foi significante. Não houve diferença estatisticamente significante entre nenhuma silicona por condensação quando comparadas simultaneamente nos 4 tempos ou quando comparadas 2 a 2, à exceção, Precise SX e a Speedex (p=0,05) no tempo T3. Todas as siliconas por condensação testadas apresentam alteração dimensional clinicamente aceitável e podem ser vazadas imediatamente, 30min, 1h e 7 dias após a moldagem. / The purpose was to evaluate the dimensional changes of condensation silicone impressions by immediately, 30min, 1h and 7 days after impression, with the help of threedimensional measuring coordinate machine. The groups were divided in: G1: Speedex Putty/Speedex Light Body (Coltène/Vigodent S/A Ind and Com), G2: Optosil P Plus/Xantopren L Blue (Heraeus Kulzer GmbH), G3: Zetaplus Putty/Oranwash L (Zhermack SpA) and G4: Precise SX (Dentsply Ind and Com Ltda). To obtain 80 measurements of 4 material (n=20) was used a device consisting of a perforated tray and one another part with 3 pre-established indentations. For dimensional evaluation, the Crysta-Plus M574 machine (Mitutoyo) held each measurement 3 times at the established times and obtained the arithmetic mean. The final average of the 4 distances of I, II, III and IV the edentulous device was again applied. Statistical analysis was performed using the Kolmogorov-Smirnov test to reject the null hypothesis of asymmetric distribution. Subsequently, ANOVA was performed to compare the four materials simultaneously and Student's t parametric test to compare the 2 by 2 materials. The overall significance level of p≤0,05. The higher linear contraction was observed in Speedex, but was not significant (p=0,08). The Zetaplus Putty/Oranwash L seems to be more stable (p=0,99) but was not significant. There was no significant difference between any silicone condensation compared simultaneously in 4 times or compared 2 by 2, except, Precise SX and Speedex (p=0,05) in T3 time. All tested condensation silicones exhibit clinically acceptable dimensional change and can be leaked immediately, 30min, 1h and 7 days after impression.
16

Avaliação volumétrica da face: validação do sistema de captação de imagem facial tridimensional pela tecnologia de luz estruturada, estudo em cadáver / Volumetric evaluation of the face: validation of the three-dimensional facial image capture system by structured light technology, cadaver study

Dornelles, Rodrigo de Faria Valle 30 January 2019 (has links)
A avaliação volumétrica da face é uma medida dimensional importante na avaliação pré-operatória, no planejamento e acompanhamento pós-operatório. Os sistemas de imagem tridimensional (3D) têm sido considerados uma ótima alternativa na mensuração linear, angular e volumétrica da face em comparação com as imagens bidimensionais (2D). Especificamente na área de atuação da Cirurgia Crânio-Maxilo-Facial, o uso da imagem em 3D na avaliação das malformações congênitas, sequelas de traumas, sequelas tumorais, planejamento de cirurgias ortognáticas, simulação de mudanças volumétricas, assimetrias faciais e outros, pode tornar o tratamento mais objetivo, rápido e potencializar os resultados. O objetivo deste projeto foi a avaliação da acurácia do cálculo volumétrico das partes moles da face a partir de malhas 3D de superfície, estudo em cadáver. Foram avaliados 09 cadáveres oriundos do Sistema de Verificação de Óbito da Capital - Universidade de São Paulo (SVO-USP). Foi incluído um expansor tecidual na região do terço médio de cada hemiface, que foi expandido progressivamente e, por meio de captação seriada de imagens tridimensionais da face com escâner de luz estruturada, foram obtidas malhas de superfície 3D a cada momento de expansão. As malhas 3D foram avaliadas quanto a variação volumétrica da região de inclusão do expansor com o uso de um software livre. O cálculo amostral supôs que as correlações encontradas apresentariam valores acima de 0,80. Para testes com poder de 80% e nível de significância de 5% seriam necessários, então, 18 hemifaces no estudo. Uma forte correlação foi observada entre todas as medições. Os gráficos de correlação linear evidenciaram um aumento linear positivo uniforme para os diferentes volumes virtuais avaliados em todas as 18 hemifaces estudadas. Todas as hemifaces não expandidas tiveram um delta significativamente menor em seções externas do cubo virtual medidas em comparação com seções externas do cubo virtual dos lados da face com expansor (P = 0,008). O grau excelente de correlação entre o volume expandido e o volume aferido virtualmente, evidenciou que obtenção de 144 malhas 3D (9 faces, 18 hemifaces, cada uma utilizada 2 vezes, uma com expansor e outra sem, totalizando 36 hemifaces estudadas com 4 malhas 3D para cada) foi uma amostra adequada para o estudo. O protocolo apresentado para o cálculo volumétrico da face com o processamento de imagem 3D assistido por computador e com a utilização de software livre em um estudo em cadáver, demonstrou versatilidade e acessibilidade, tendo sido comprovada a sua acurácia / The face volumetric evaluation is an important dimensional measure in the preoperative evaluation in planning and postoperative follow-up. 3D imaging systems have been considered a good alternative in linear and angular measurement of face compared to 2D images. Specifically, in Cranio-Maxillofacial Surgery area, the 3D imaging use in the evaluation of congenital malformations, trauma sequelae, tumor sequelae, orthognathic surgery planning, volumetric changes simulation, facial imbalances and others could turn the treatment more objective, faster and potentiate the results. This project objective was calculation volumetric accuracy evaluation of the soft face parts from 3D surface meshes cadaver study. We evaluated 9 cadavers from the Sistema de Verificação de Óbito da Capital - Universidade de São Paulo (SVO-USP). A tissue expander was included in each middle third hemiface region which was progressively expanded and by means of serial three-dimensional face images acquisition with light scanners surface 3D meshes structured were obtained at expansion each moment. The 3D meshes were evaluated for the expander inclusion region volumetric variation with free software use. The sample calculation assumed that the correlations found would have values above 0.80. Eighteen hemifaces would be necessary in the study for tests with a power of 80% and a level of significance of 5%. A strong correlation was observed between all measurements. The linear correlation graphs showed a positive consistent linear increase for different virtual volumes evaluated in all 18 hemifaces studied. All unexpanded hemifaces had a significantly lower delta in outer virtual cube measured sections compared to virtual cube on face sides with expander (P = 0.008) external sections. The excellent degree of correlation between the expanded volume and the virtually verified volume showed that obtaining 144 3D meshes (9 faces, 18 hemifaces, each one used 2 times, one with expander and one without, totaling 36 hemifaces studied with 4 3D meshes for each) was an adequate sample for the study. The protocol presented for face volumetric calculation with computer assisted 3D image processing and the free software use in a cadaver study demonstrated versatility and accessibility and its accuracy was proven

Page generated in 0.1492 seconds