• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 9
  • 1
  • 1
  • Tagged with
  • 11
  • 11
  • 10
  • 9
  • 9
  • 8
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Three-dimensional photoelastic stress analysis of a free-end partial denture with a bottomed-out and non-bottomed-out parallel precision attachment

Arfaei, A. Hamid. January 1976 (has links)
Thesis (M.S.)--University of Michigan, Ann Arbor, 1976. / Typescript (photocopy). eContent provider-neutral record in process. Description based on print version record. Includes bibliographical references (leaves 128-134).
2

Comparison of relative deflection in a fixed partial prosthesis with a soldered joint and an semi-fixed partial prosthesis with a precision attachment under simulated occlusal forces

Burns, J. William January 1973 (has links)
Thesis (M.Sc.D.)--Boston University School of Graduate Dentistry, 1973. Prosthodontics. / Bibliography included. / Precision and semi-precision attachments have been utilized in fixed partial prostheses for many years. A review of the dental literature reveals a lack of clinical and laboratory information and their use in specific situations therefore must have been empiricly established . The purpose of this research was to contribute to the establishment of either a sound rationale for the use of precision attachments or, conversely, to an indictment of them based on factual testing under simulated clinical conditions. [TRUNCATED]
3

Comparação da contaminação microbiana de dois sistemas de encaixe para sobredentaduras mandibulares retidas por implantes. Estudo clínico randomizado / Microbial contamination comparison of two attachment systems for implant retained mandibular overdentures - randomized clinical trial

Pinheiro, Marília Lamenha Lins 30 May 2018 (has links)
A colonização e proliferação de micro-organismos periodontopatogênicos na gengiva marginal aos implantes dentários, assim como ao redor de seus componentes protéticos, pode representar riscos à saúde dos tecidos peri-implantares, à semelhança do que ocorre com os tecidos periodontais. O objetivo deste estudo foi identificar e quantificar 32 espécies microbianas de biofilmes coletados das superfícies de dois sistemas de encaixe para sobredentaduras retidas por implantes: um esférico (Retentive Anchor, Institut Straumann AG, Suíça - RA) e um cilíndrico (Locator, Zest Anchors Inc., CA-USA - Loc), das próteses, implantes e sulcos peri-implantares, ao longo do tempo. Os biofilmes analisados foram coletados em um estudo randomizado envolvendo 24 pacientes portadores de prótese total superior e sobredentadura inferior retida por dois implantes com sistemas de encaixe esférico RA (n= 12) ou cilíndrico Loc (n= 12). Amostras de biofilme foram coletadas de sete sítios para cada implante, nos períodos: após a instalação de novos encaixes (baseline), assim como aos 3 e 12 meses subsequentes. A identificação e quantificação das espécies microbianas foram realizadas por meio da técnica de hibridização DNA-DNA Checkerboard. Os resultados foram submetidos à análise não paramétrica de modelo misto ANOVAF, e matriz de covariância não estruturada para cada tratamento, com nível de significância de 0.05, posteriormente ajustado por Benjamini-Hochberg false discovery rate (FDR). Considerando-se todos os sítios e períodos investigados em conjunto e as 32 espécies bacterianas investigadas, apenas a S. constellatus foi encontrada em maior abundância nos biofilmes associados ao sistema RA. A análise sítio-específica revelou maior prevalência das espécies S. constellatus e P. micra na rosca do componente macho do encaixe esférico RA e da espécie S. sanguinis na superfície externa do componente macho do encaixe cilíndrico Loc. De modo geral, pôde-se concluir que os sistemas de encaixe para retenção de sobredentaduras RA e Loc são colonizados por microbiotas com perfis semelhantes, embora esses sistemas exerçam influência seletiva sobre o padrão de colonização das espécies bacterianas S. constelatus, P. micra e S. sanguinis / The colonization and proliferation of periodontopathogenic microorganisms in the dental implants marginal gingiva, as well as around their prosthetic components, may represent risks to the health of the peri-implant tissues, similar to what occurs with the periodontal tissues. The objective of this study was to identify and quantify 32 microbial species of biofilms collected from the surfaces of two attachment systems for implant retained mandibular overdentures: one spherical (Retentive Anchor, Institut Straumann AG, Switzerland - RA) and one cylindrical (Locator, Zest Anchors Inc., CA-USA - Loc), of prostheses, implants and peri-implant sulcus, over time. The biofilms analyzed were collected in a randomized study involving 24 patients with superior complete dentures and inferior overdenture retained by two implants with spherical attachment RA (n = 12) or cylindrical Loc (n = 12) systems. Biofilm samples were collected from seven sites of each implant, at the periods: after new attachments installation (baseline), as well at the next 3 and 12 months. The microbial species identification and quantification were carried out using DNA-DNA Checkerboard hybridization technique. The results were submitted to the mixed model non-parametric analysis \"ANOVAF\" and non-structured covariance matrix for each treatment, with 0.05 significance level, later adjusted by \"Benjamini-Hochberg\" false discovery rate (FDR). Considering all the sites and periods investigated together and the 32 bacterial species investigated, only S. constellatus was found in greater abundance in the biofilms associated to the RA system. The site-specific analysis revealed a higher prevalence of S. constellatus and P. micra species on the male component of the RA spherical attachment and of S. sanguinis species on the outer surface of the male component of the cylindrical Loc attachment. In general, it can be concluded that the overdenture attachment systems RA and Loc are colonized by microbiotas with similar profiles, although these systems exert a selective influence on the colonization pattern of S. constelatus, P. micra and S. sanguinis bacterial species
4

Avaliação da capacidade retentiva de sistema de encaixe o\'ring submetido a soluções de higienização diárias e à ciclagem mecânica / Evaluation of retention force of o\'ring overdenture system subjected to daily hygiene solutions and fatigue

Crizóstomo, Luciana Costa 10 December 2013 (has links)
A imersão de overdentures em soluções de higienização diárias associadas a constantes inserções e remoções podem comprometer seus componentes. Em função disso, o objetivo deste estudo foi avaliar a capacidade retentiva de o′rings (Conexão Sistemas de Prótese, Ltda) quando submetidos a imersões em soluções e ciclagem mecânica. Foram avaliadas as soluções: Cepacol (C), Cepacol Flúor (CF), Listerine (L), Hipoclorito de sódio 0,05% (HS) e água deionizada (AD), como controle positivo e a não imersão (SI), como controle negativo. Foi obtida uma base de nylon 6.6 contendo dois pilares o′ring, com plataforma protética (HI) de implantes e contra-bases com as cápsulas metálicas e anéis de nitrilo, que foram divididas em grupos (n = 6). Foram simulados 180 dias de imersão overnight e realizados 720 ciclos de inserção e remoção, com ensaios de fadiga. O valor da resistência à tração foi registrado a cada 30 dias e 120 ciclos, utilizando-se máquina de ensaios mecânicos, totalizando 7 leituras (T0, T1, T2, T3, T4, T5, T6). Os dados da capacidade retentiva (N) foram analisados estatisticamente pelos testes ANOVA e Bonferroni (α=0,05). Os resultados demonstraram diferenças significativas para o tempo (p= 0,0000) e para as soluções (p= 0,0000) e para a interação tempo X solução (p=0,0192). A capacidade retentiva no T0 (8,41 N) foi maior que no T1 (6,94 N), T2 (6,87 N), T3 (6,66 N), T4 (7,02 N), T5 (5,84 N) e T6 (5,02). Em relação às soluções, o HS propiciou obtenção de maior capacidade retentiva (8,37 N) que os demais grupos: AD (6,68 N), L (6,52 N), SI (6,43 N), CF (6,28 N) e C (5,77 N). Quanto às interações, a capacidade retentiva inicial de todos os grupos, com exceção do HS, foi maior que a final, entretanto é prematuro recomendá-lo para uso como higienizador. Desta forma, conclui-se que o Listerine, Cepacol e Cepacol Flúor apresentaram comportamentos semelhantes aos grupos controles, sendo, portanto, bem indicados como soluções para imersão de overdentures. / Denture cleansers associated with constant insertion and removal of overdentures may have deleterious effects on its components. Therefore, the aim of this study was to evaluate the effect of these solutions and fatigue strength on the retention loss of overdentures o´rings (Conexão Sistemas de Prótese, Ltda). Effect of 5 solutions were studied: Cepacol (C), Cepacol Flúor (CF), Listerine (L), 0,05% sodium hypochlorite (SH) and deionized water (DA, positive control) and without immersion (WI, negative control). Nylon 6.6 matrices containing 2 implants and abutments and acrylic specimens with the metal caps were obtained and divided in 6 groups (n=6). One hundred eighty days overnight soaks were simulated and 720 pulls were performed in fatigues test. The dislodging force was evaluated at baseline (T0) and after every 30 immersions and 120 pulls, using testing machine. There were performed 7 tests (T0, T1, T2, T3, T4, T5 e T6). The data were statistically analyzed by ANOVA and Bonferroni tests (α=0.05). The results were differents with time (p= 0.0000), solutions (p= 0.0000) and also interaction (p=0.0192). The retention T0 (8.41 N) was higher than T1 (6.94 N), T2 (6.87 N), T3 (6.66 N), T4 (7.02 N), T5 (5.84 N) and T6 (5.02). For solutions, the HS showed a higher mean (8.37 N), followed by AD (6.68 N), L (6.52 N), SI (6.43 N), CF (6.28 N), and C (5.77 N). Regarding interactions, the initial retention groups were higher than the final, with the exception of HS, however it is premature to recommend it for use as a cleanser. Thus, it can be concluded that Listerine, Cepacol, Cepacol Fluor behaved similarly to the control groups, and therefore well indicated as solutions for overdenture immersions.
5

Avaliação da força de retenção de encaixes o\'ring submetidos a soluções de higienização diárias / Evaluation of retention force of o\'ring attachments subjected to daily hygiene solutions

Felipucci, Daniela Nair Borges 10 September 2013 (has links)
Soluções auxiliares para higienização de próteses têm sido indicadas como método efetivo no controle de biofilme. Desta forma, este estudo teve por objetivo avaliar se as soluções (Cepacol/C, Cepacol Flúor/CF, Listerine/L, hipoclorito de sódio 0,05%/HS e água deionizada/AD, como controle) potencializam a perda de retenção do o\'ring (Conexão Sistemas de Prótese Ltda). Foi obtida uma base de teflon com dois análogos e pilares o\'ring e contra-bases, compostas pelas cápsulas metálicas e anéis, foram confeccionadas e divididas em grupos (n=6). Foram simulados 90 dias de imersão overnight, sendo obtido o valor da resistência à tração a cada 30 dias, utilizando a máquina de ensaios mecânicos (Material Testing System MTS 810), totalizando 4 leituras (T0, T1, T2 e T3). Foi realizada análise qualitativa por meio de microscopia eletrônica de varredura em um espécime de cada grupo. Os dados da força de retenção (N) foram analisados estatisticamente pelos testes ANOVA e Bonferroni (α=0,05). Os resultados demonstraram que a retenção diminuiu significativamente com o tempo (P=0,0001) e com o uso das soluções (P=0,0000) e houve interação entre os fatores de variação (P=0,0245). A retenção no T0 (11,25) foi maior que no T1 (9,63), T2 (8,76) e T3 (8,40). No T1 foi maior que nos demais tempos e entre T2 e T3 não houve diferença significante. Entre as soluções avaliadas, o HS causou a maior redução da força de retenção (7,00). Os enxaguatórios C e L propiciaram médias similares (10,41 e 10,09, respectivamente) à AD (10,91). O CF propiciou resistência similar (9,14) aos enxaguatórios C e L. No C e no HS a retenção diminuiu significativamente a partir de 30 dias. No L e no CF, a diminuição da retenção ocorreu após 60 dias. Na AD, a retenção se manteve pelo período de 90 dias. Após 90 dias, o C propiciou retenção similar à água deionizada. As eletromicrografias apontaram alteração dos anéis: no do grupo do HS, houve presença de solução de continuidade do material e no do CF, formação de uma película com precipitados cristalinos. Conclui-se que após 3 meses de imersão, os valores obtidos em todas as soluções se apresentaram acima do mínimo indicado para a retenção (5 N), entretanto as soluções de hipoclorito de sódio 0,05% e Cepacol Flúor devem ser evitadas devido aos efeitos deletérios causados no material. / Denture cleansers have been widely indicated as an effective auxiliary method to biofilm control. The aim of this study was to evaluate the effect of these solutions Cepacol/C, Cepacol Fluor/CF, Listerine/L, 0,05% sodium hypochlorite/SH and deionized water /DA - control) on the retention loss of overdentures nytril o\'rings (Conexão Sistemas de Prótese Ltda). Teflon dies containing 2 implants and abutments and acrylic specimens with the metal caps were obtained and divided into the groups (n = 6). Ninety overnight soaks were performed simulating 3 months of care. At each 30 immersions, the peak load of tensile strength was registered (Material Testing System MTS 810), and 4 tests wereperformed (T0, T1, T2 e T3). Qualitative method by scanning electronic microscopy (SEM) was used for complementary analyzes. The data were statistically analyzed by the ANOVA and Bonferroni tests (α=0.05). The results showed that the retention decreased with time (P = 0.0001) and with the use of solutions (P = 0.0000) and there was interaction between variation factors (P = 0.0245). Retention in T0 (11.25) was higher than in T1 (9.63), T2 (8.76) and T3 (8.40). In T1, the retention was higher than in other times and between T2 and T3 no significant difference. Among the solutions evaluated, the HS caused the greatest reduction in retention force (7.00). The C and L rinses propitiated similar averages (10.41 and 10.09, respectively) to AD (10.91). The CF provided similar resistance (9.14) to C and L rinses In C and HS, the retention decreased significantly from 30 days. In CF and L, the retention decrease occurred after 60 days. In AD, the retention was maintained for 90 days. After 90 days, C promoted retention similar to deionized water. The electron micrographs showed alteration of the rings: in HS group, there was presence of a discontinuity of the material and in CF, there was a film forming with crystalline precipitates. It can be concluded that after 3 months of immersion, the values of all the solutions were above the minimum suitable for retaining (5 N), however, solutions of sodium hypochlorite 0.05% and Cepacol Fluor should be avoided due to deleterious effects on the material.
6

Avaliação da capacidade retentiva de sistema de encaixe o\'ring submetido a soluções de higienização diárias e à ciclagem mecânica / Evaluation of retention force of o\'ring overdenture system subjected to daily hygiene solutions and fatigue

Luciana Costa Crizóstomo 10 December 2013 (has links)
A imersão de overdentures em soluções de higienização diárias associadas a constantes inserções e remoções podem comprometer seus componentes. Em função disso, o objetivo deste estudo foi avaliar a capacidade retentiva de o′rings (Conexão Sistemas de Prótese, Ltda) quando submetidos a imersões em soluções e ciclagem mecânica. Foram avaliadas as soluções: Cepacol (C), Cepacol Flúor (CF), Listerine (L), Hipoclorito de sódio 0,05% (HS) e água deionizada (AD), como controle positivo e a não imersão (SI), como controle negativo. Foi obtida uma base de nylon 6.6 contendo dois pilares o′ring, com plataforma protética (HI) de implantes e contra-bases com as cápsulas metálicas e anéis de nitrilo, que foram divididas em grupos (n = 6). Foram simulados 180 dias de imersão overnight e realizados 720 ciclos de inserção e remoção, com ensaios de fadiga. O valor da resistência à tração foi registrado a cada 30 dias e 120 ciclos, utilizando-se máquina de ensaios mecânicos, totalizando 7 leituras (T0, T1, T2, T3, T4, T5, T6). Os dados da capacidade retentiva (N) foram analisados estatisticamente pelos testes ANOVA e Bonferroni (α=0,05). Os resultados demonstraram diferenças significativas para o tempo (p= 0,0000) e para as soluções (p= 0,0000) e para a interação tempo X solução (p=0,0192). A capacidade retentiva no T0 (8,41 N) foi maior que no T1 (6,94 N), T2 (6,87 N), T3 (6,66 N), T4 (7,02 N), T5 (5,84 N) e T6 (5,02). Em relação às soluções, o HS propiciou obtenção de maior capacidade retentiva (8,37 N) que os demais grupos: AD (6,68 N), L (6,52 N), SI (6,43 N), CF (6,28 N) e C (5,77 N). Quanto às interações, a capacidade retentiva inicial de todos os grupos, com exceção do HS, foi maior que a final, entretanto é prematuro recomendá-lo para uso como higienizador. Desta forma, conclui-se que o Listerine, Cepacol e Cepacol Flúor apresentaram comportamentos semelhantes aos grupos controles, sendo, portanto, bem indicados como soluções para imersão de overdentures. / Denture cleansers associated with constant insertion and removal of overdentures may have deleterious effects on its components. Therefore, the aim of this study was to evaluate the effect of these solutions and fatigue strength on the retention loss of overdentures o´rings (Conexão Sistemas de Prótese, Ltda). Effect of 5 solutions were studied: Cepacol (C), Cepacol Flúor (CF), Listerine (L), 0,05% sodium hypochlorite (SH) and deionized water (DA, positive control) and without immersion (WI, negative control). Nylon 6.6 matrices containing 2 implants and abutments and acrylic specimens with the metal caps were obtained and divided in 6 groups (n=6). One hundred eighty days overnight soaks were simulated and 720 pulls were performed in fatigues test. The dislodging force was evaluated at baseline (T0) and after every 30 immersions and 120 pulls, using testing machine. There were performed 7 tests (T0, T1, T2, T3, T4, T5 e T6). The data were statistically analyzed by ANOVA and Bonferroni tests (α=0.05). The results were differents with time (p= 0.0000), solutions (p= 0.0000) and also interaction (p=0.0192). The retention T0 (8.41 N) was higher than T1 (6.94 N), T2 (6.87 N), T3 (6.66 N), T4 (7.02 N), T5 (5.84 N) and T6 (5.02). For solutions, the HS showed a higher mean (8.37 N), followed by AD (6.68 N), L (6.52 N), SI (6.43 N), CF (6.28 N), and C (5.77 N). Regarding interactions, the initial retention groups were higher than the final, with the exception of HS, however it is premature to recommend it for use as a cleanser. Thus, it can be concluded that Listerine, Cepacol, Cepacol Fluor behaved similarly to the control groups, and therefore well indicated as solutions for overdenture immersions.
7

Avaliação da força de retenção de encaixes o\'ring submetidos a soluções de higienização diárias / Evaluation of retention force of o\'ring attachments subjected to daily hygiene solutions

Daniela Nair Borges Felipucci 10 September 2013 (has links)
Soluções auxiliares para higienização de próteses têm sido indicadas como método efetivo no controle de biofilme. Desta forma, este estudo teve por objetivo avaliar se as soluções (Cepacol/C, Cepacol Flúor/CF, Listerine/L, hipoclorito de sódio 0,05%/HS e água deionizada/AD, como controle) potencializam a perda de retenção do o\'ring (Conexão Sistemas de Prótese Ltda). Foi obtida uma base de teflon com dois análogos e pilares o\'ring e contra-bases, compostas pelas cápsulas metálicas e anéis, foram confeccionadas e divididas em grupos (n=6). Foram simulados 90 dias de imersão overnight, sendo obtido o valor da resistência à tração a cada 30 dias, utilizando a máquina de ensaios mecânicos (Material Testing System MTS 810), totalizando 4 leituras (T0, T1, T2 e T3). Foi realizada análise qualitativa por meio de microscopia eletrônica de varredura em um espécime de cada grupo. Os dados da força de retenção (N) foram analisados estatisticamente pelos testes ANOVA e Bonferroni (α=0,05). Os resultados demonstraram que a retenção diminuiu significativamente com o tempo (P=0,0001) e com o uso das soluções (P=0,0000) e houve interação entre os fatores de variação (P=0,0245). A retenção no T0 (11,25) foi maior que no T1 (9,63), T2 (8,76) e T3 (8,40). No T1 foi maior que nos demais tempos e entre T2 e T3 não houve diferença significante. Entre as soluções avaliadas, o HS causou a maior redução da força de retenção (7,00). Os enxaguatórios C e L propiciaram médias similares (10,41 e 10,09, respectivamente) à AD (10,91). O CF propiciou resistência similar (9,14) aos enxaguatórios C e L. No C e no HS a retenção diminuiu significativamente a partir de 30 dias. No L e no CF, a diminuição da retenção ocorreu após 60 dias. Na AD, a retenção se manteve pelo período de 90 dias. Após 90 dias, o C propiciou retenção similar à água deionizada. As eletromicrografias apontaram alteração dos anéis: no do grupo do HS, houve presença de solução de continuidade do material e no do CF, formação de uma película com precipitados cristalinos. Conclui-se que após 3 meses de imersão, os valores obtidos em todas as soluções se apresentaram acima do mínimo indicado para a retenção (5 N), entretanto as soluções de hipoclorito de sódio 0,05% e Cepacol Flúor devem ser evitadas devido aos efeitos deletérios causados no material. / Denture cleansers have been widely indicated as an effective auxiliary method to biofilm control. The aim of this study was to evaluate the effect of these solutions Cepacol/C, Cepacol Fluor/CF, Listerine/L, 0,05% sodium hypochlorite/SH and deionized water /DA - control) on the retention loss of overdentures nytril o\'rings (Conexão Sistemas de Prótese Ltda). Teflon dies containing 2 implants and abutments and acrylic specimens with the metal caps were obtained and divided into the groups (n = 6). Ninety overnight soaks were performed simulating 3 months of care. At each 30 immersions, the peak load of tensile strength was registered (Material Testing System MTS 810), and 4 tests wereperformed (T0, T1, T2 e T3). Qualitative method by scanning electronic microscopy (SEM) was used for complementary analyzes. The data were statistically analyzed by the ANOVA and Bonferroni tests (α=0.05). The results showed that the retention decreased with time (P = 0.0001) and with the use of solutions (P = 0.0000) and there was interaction between variation factors (P = 0.0245). Retention in T0 (11.25) was higher than in T1 (9.63), T2 (8.76) and T3 (8.40). In T1, the retention was higher than in other times and between T2 and T3 no significant difference. Among the solutions evaluated, the HS caused the greatest reduction in retention force (7.00). The C and L rinses propitiated similar averages (10.41 and 10.09, respectively) to AD (10.91). The CF provided similar resistance (9.14) to C and L rinses In C and HS, the retention decreased significantly from 30 days. In CF and L, the retention decrease occurred after 60 days. In AD, the retention was maintained for 90 days. After 90 days, C promoted retention similar to deionized water. The electron micrographs showed alteration of the rings: in HS group, there was presence of a discontinuity of the material and in CF, there was a film forming with crystalline precipitates. It can be concluded that after 3 months of immersion, the values of all the solutions were above the minimum suitable for retaining (5 N), however, solutions of sodium hypochlorite 0.05% and Cepacol Fluor should be avoided due to deleterious effects on the material.
8

Efeito de soluções higienizadoras na retenção de cápsulas do tipo o\'ring / Effect of denture cleansers on the retention of capsules type o-ring

Pacheco, Thereza Cristina Lira 04 September 2015 (has links)
Soluções higienizadoras podem acarretar efeitos prejudiciais para as próteses, como deterioração da base da prótese e pigmentação. Porém, pouco se conhece sobre os efeitos destas na vida útil dos sistemas de retenção de uma overdenture. Deste modo, este estudo buscou avaliar se imersões diárias em clorexidina 2%, hipoclorito de sódio 1%, Corega® Tabs e água (controle) poderia acelerar a perda de retenção em attachments do tipo o´ring (S.I.N sistema de implantes®). Foram confeccionados 40 corpos de prova contendo cápsulas com anéis de borracha, simulando uma overdenture, e apenas 01 contendo o implante com o pilar o´ring. Eles foram separados em quatro grupos (n=10) e simulados noventa dias de imersões. Após, foram realizados testes de resistência à tração em uma máquina de ensaios mecânicos (MTS 810), antes e após a ciclagem com 270 ciclos, equivalentes a remoção e inserção da prótese três vezes ao dia, durante um período de três meses. Os resultados foram avaliados estatisticamente através dos testes ANOVA a dois critérios e do teste de Tukey (p≤0.05). Os valores médios (Newton) encontrados antes e após a imersão foram, respectivamente: Água - 9,482 / 6,081; Clorexidina - 9,972 / 7,390; Hipoclorito: 6,954 / 6,265 e Corega® Tabs: 12,464 / 11,121. Entre os grupos Clorexidina, Hipoclorito de sódio e Água não houve diferenças significativas. Houve diferenças estatisticamente significativas entre o grupo Corega® Tabs e os grupos controle e Hipoclorito de sódio, mas não com a Clorexidina. Assim, pôde-se concluir que soluções higienizadoras tiveram efeitos significativos na capacidade de retenção dos o´rings após o período simulado de três meses de imersão. / Denture cleansers can cause adverse effects on the prostheses, as deterioration of the denture base and pigmentation. However, little is known about its impacts on the life of an overdenture retention systems. Thus, this study sought to evaluate whether daily immersion in chlorhexidine 2%, sodium hypochlorite 1%, Corega® Tabs and water (control) would increase the retention loss in the O-ring type attachments (SIN implantes® system). Forty specimens containing capsules were made with rubber rings, simulating an overdenture, and only one containing the implant with the O-ring abutment. They were divided into four groups (n = 10) and ninety days in immersion were simulated, thereafter, conducted tensile strength tests on a testing machine (MTS - 810) before and after cycling of 270 cycles, equivalent to removal and insertion of the prosthesis three times a day for a period of three months. The results were statistically evaluated by the ANOVA two criteria and the Tukey test (p≤0.05). The mean values (Newton) found before and after immersion were: Water - 9,482 / 6,081; Chlorhexidine - 9,972 / 7,390; Hypochlorite: 6,954 / 6,265 and Corega® Tabs: 12.464 / 11.121. Among the groups chlorhexidine, sodium hypochlorite and water there were no significant differences. There were statistically significant differences between the group Corega® Tabs and controls and sodium hypochlorite groups, but not with the chlorhexidine. Thus, it concluded that denture cleansers had significant effects on retention capacity of orings after the simulated period of three months of immersion.
9

Efeito de soluções higienizadoras na retenção de cápsulas do tipo o\'ring / Effect of denture cleansers on the retention of capsules type o-ring

Thereza Cristina Lira Pacheco 04 September 2015 (has links)
Soluções higienizadoras podem acarretar efeitos prejudiciais para as próteses, como deterioração da base da prótese e pigmentação. Porém, pouco se conhece sobre os efeitos destas na vida útil dos sistemas de retenção de uma overdenture. Deste modo, este estudo buscou avaliar se imersões diárias em clorexidina 2%, hipoclorito de sódio 1%, Corega® Tabs e água (controle) poderia acelerar a perda de retenção em attachments do tipo o´ring (S.I.N sistema de implantes®). Foram confeccionados 40 corpos de prova contendo cápsulas com anéis de borracha, simulando uma overdenture, e apenas 01 contendo o implante com o pilar o´ring. Eles foram separados em quatro grupos (n=10) e simulados noventa dias de imersões. Após, foram realizados testes de resistência à tração em uma máquina de ensaios mecânicos (MTS 810), antes e após a ciclagem com 270 ciclos, equivalentes a remoção e inserção da prótese três vezes ao dia, durante um período de três meses. Os resultados foram avaliados estatisticamente através dos testes ANOVA a dois critérios e do teste de Tukey (p≤0.05). Os valores médios (Newton) encontrados antes e após a imersão foram, respectivamente: Água - 9,482 / 6,081; Clorexidina - 9,972 / 7,390; Hipoclorito: 6,954 / 6,265 e Corega® Tabs: 12,464 / 11,121. Entre os grupos Clorexidina, Hipoclorito de sódio e Água não houve diferenças significativas. Houve diferenças estatisticamente significativas entre o grupo Corega® Tabs e os grupos controle e Hipoclorito de sódio, mas não com a Clorexidina. Assim, pôde-se concluir que soluções higienizadoras tiveram efeitos significativos na capacidade de retenção dos o´rings após o período simulado de três meses de imersão. / Denture cleansers can cause adverse effects on the prostheses, as deterioration of the denture base and pigmentation. However, little is known about its impacts on the life of an overdenture retention systems. Thus, this study sought to evaluate whether daily immersion in chlorhexidine 2%, sodium hypochlorite 1%, Corega® Tabs and water (control) would increase the retention loss in the O-ring type attachments (SIN implantes® system). Forty specimens containing capsules were made with rubber rings, simulating an overdenture, and only one containing the implant with the O-ring abutment. They were divided into four groups (n = 10) and ninety days in immersion were simulated, thereafter, conducted tensile strength tests on a testing machine (MTS - 810) before and after cycling of 270 cycles, equivalent to removal and insertion of the prosthesis three times a day for a period of three months. The results were statistically evaluated by the ANOVA two criteria and the Tukey test (p≤0.05). The mean values (Newton) found before and after immersion were: Water - 9,482 / 6,081; Chlorhexidine - 9,972 / 7,390; Hypochlorite: 6,954 / 6,265 and Corega® Tabs: 12.464 / 11.121. Among the groups chlorhexidine, sodium hypochlorite and water there were no significant differences. There were statistically significant differences between the group Corega® Tabs and controls and sodium hypochlorite groups, but not with the chlorhexidine. Thus, it concluded that denture cleansers had significant effects on retention capacity of orings after the simulated period of three months of immersion.
10

Influência dos sistemas de retenção e da inclinação do rebordo residual em casos de próteses conjugadas Classe I mandibular: análise da distribuição das tensões pelo método da fotoelasticidade

Ferraço, Renato [UNESP] 24 April 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-04-24Bitstream added on 2014-06-13T19:37:37Z : No. of bitstreams: 1 ferraco_r_me_araca.pdf: 1898873 bytes, checksum: a4b549caf699d7868a711624716d6212 (MD5) / A reabilitação de pacientes classe I de Kennedy mandibular através de Prótese Parcial Removível é de difícil resolução devido a diferença de resiliência existente entre o ligamento periodontal dos dentes suportes e a mucosa do rebordo residual. A inclinação do rebordo residual no sentido sagital pode influenciar na distribuição das tensões transmitidas pela incidência de cargas em próteses parciais removíveis de extremidade livre associadas a próteses parciais fixas. Na associação da prótese parcial removível com próteses parciais fixas, o profissional tem como alternativa aos grampos tradicionais, o uso de encaixes extra-coronários que podem melhorar a estética e o funcionamento biomecânico do conjunto. Desse modo, o objetivo desse estudo foi avaliar a característica da distribuição de tensões em próteses parciais removíveis mandibulares de extremidade livre associadas a próteses parciais fixas nos dentes suporte com diferentes sistemas de retenção: (1) grampo por ação de pontas; (2) sistema ASC-52; (3) sistema ERA; e (4) encaixe de semi-precisão Score-PD, pela metodologia da fotoelasticidade. E, analisar a distribuição de tensões em próteses parciais removíveis mandibulares de extremidade livre associadas a próteses parciais fixas nos dentes suporte com diferentes sistemas de retenção: (1) grampo por ação de pontas e (2) sistema ERA, variando duas inclinações de rebordo residual: (1) horizontal e (2) descendente distal. Cargas axiais de 100N foram aplicadas sobre os dentes das próteses parciais removíveis. As imagens das aplicações foram capturadas e a distribuição das tensões foi avaliada, pela formação das franjas fotoelásticas. No primeiro estudo, a prótese com encaixes de semi-precisão produziu os maiores níveis de tensão na região de ápice, entre as raízes dos últimos dentes suporte e na porção mais distal do rebordo... / The rehabilitation of patients mandibular class I of Kennedy through Removable Partial Denture is difficult to solve because the difference in strength between the periodontal ligament of the abutment teeth and the residual ridge mucosa. The inclination of the residual ridge towards sagital may influence the distribution of stresses transmitted by the incidence of loads in distal extension removable partial dentures associated with fixed partial dentures. In association removable partial denture – fixed partial dentures, the professional has as alternative to the traditional clasps, the use of extra-coronary attachments that can improve the aesthetics and the biomechanics. Therefore, the objective of this study was to evaluate the characteristic distribution of tensions in mandibular distal extension removable partial dentures (1) “I” bar clasps, (2) ASC-52system, (3) ERA system, and (4) semi-precision Score-PD system, by the methodology of photoelasticity. And, analyze the distribution of tensions in mandibular distal extension removable partial dentures associated to the fixed partial dentures in the abutment teeth with different retention systems: (1) “I” bar clasps and (2) ERA system, ranging from two inclinations residual ridge: (1) horizontal and (2) distal descending. Axial loads of 100N were applied on the teeth of removable partial dentures. The images of the applications were captured and distribution of stress was assessed by the formation of the photoelastic fringes. In the first study, the prosthesis with semi-precision attachment produced the highest levels of tension in the region of apex, between the roots of the abutment teeth and in the more distal portion of the residual ridge. The prostheses with resilient attachments showed the largest fringes formations in the cervical-distal of the last abutment tooth. In the second study, horizontal ridge presented... (Complete abstract click electronic access below)

Page generated in 0.5304 seconds