• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 708
  • 403
  • 256
  • 96
  • 87
  • 53
  • 19
  • 17
  • 16
  • 10
  • 10
  • 9
  • 8
  • 6
  • 6
  • Tagged with
  • 2240
  • 452
  • 369
  • 295
  • 215
  • 200
  • 172
  • 164
  • 151
  • 142
  • 132
  • 129
  • 122
  • 119
  • 110
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
361

Determinacao de elementos em baixa concentracao e em concentracao de tracos em amostras de magnesita, por analise por ativacao

SEPULVEDA MUNITA, CASIMIRO J.A. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:29:43Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:59:50Z (GMT). No. of bitstreams: 1 00023.pdf: 1054827 bytes, checksum: 051f292ba75d9989421dce6e25e0477e (MD5) / Dissertacao (Mestrado) / IEA/D / Instituto de Quimica, Universidade de Sao Paulo - IQ/USP
362

Estudo sobre a determinação de antimônio em amostras ambientais pelo método de análise por ativação com nêutrons. Validação da metodologia e determinação da incerteza da medição / A study on antimony determination in environmental samples by neutron activation analysis. Validation of the methodology and determination of the uncertainty of the measurement

MATSUBARA, TASSIANE C.M. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:34:07Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:00:09Z (GMT). No. of bitstreams: 0 / O antimônio é um elemento encontrado em baixas concentrações no meio ambiente. No entanto, a sua determinação tem despertado grande interesse devido ao conhecimento de sua toxicidade e da crescente aplicação na indústria. A determinação de antimônio tem sido um desafio para os pesquisadores uma vez que o elemento é encontrado em baixas concentrações, o que faz de sua análise uma tarefa difícil. Portanto, embora a análise por ativação de nêutrons (NAA) seja um método adequado para a determinação de vários elementos em diferentes tipos de matriz, no caso de Sb, a análise apresenta algumas dificuldades. A principal dificuldade é devido às interferências espectrais. O objetivo desta pesquisa foi validar o método de NAA para a determinação de Sb em amostras ambientais. Para estabelecer condições adequadas para a determinação de Sb, ensaios preliminares foram realizados para posterior análise de materiais de referência certificados (MRC). O procedimento experimental consistiu em irradiar amostras juntamente com padrão sintético de Sb por períodos de 8 ou 16 horas no reator nuclear de pesquisa IEA-R1, seguido de espectrometria de raios gama. A quantificação de Sb foi realizada pela medição dos radioisótopos de 122Sb e 124Sb. Ensaios preliminares indicaram a presença de Sb em papel de filtro Whatman, utilizado no preparo do padrão, porém em teor muito baixo, podendo ser considerado desprezível. No caso do material plástico utilizado como invólucro para a irradiação da amostra, foi verificado que ele deve ser escolhido cuidadosamente, pois dependendo do plástico, este pode conter Sb. A análise da estabilidade da solução padrão diluída de Sb, dentro do período de oito meses, mostrou que não há alteração significativa na concentração deste elemento. Os resultados obtidos nas análises dos materiais de referência certificados indicaram a formação de radioisótopos de 76As e também de 134Cs e 152Eu, podendo interferir na determinação de Sb pela medição de 122Sb, devido à proximidade de energias dos raios gama emitidos. Além disso, a alta atividade do 24Na pode mascarar o pico do 122Sb e dificultar a sua detecção. As análises dos MRC indicaram que a exatidão e a precisão dos resultados de Sb dependem principalmente do tipo e composição da matriz, da sua concentração na amostra, do radioisotopo medido e do tempo de decaimento utilizado para a medição. A avaliação dos componentes que contribuem para a medição da incerteza da concentração de Sb, mostrou que a maior contribuição da incerteza é dada pela estatística de contagem da amostra. Os resultados da avaliação da incerteza indicaram também que o valor da incerteza padrão combinada depende do radioisótopo medido e do tempo de decaimento utilizado para as contagens. Este estudo mostrou que a NAA é um método bastante adequado na determinação de Sb em amostras ambientais, possibilitando a obtenção de resultados com baixos valores de incerteza e por ser uma técnica puramente instrumental, permite a análise de um grande número de amostras. / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
363

Obtencao e caracterizacao de ceramicas de ceria com dupla dopagem

TADOKORO, SANDRA K. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:49:52Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:02:36Z (GMT). No. of bitstreams: 1 09984.pdf: 10774307 bytes, checksum: a193fefe92c978f1963dcaad657ea1e2 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP / FAPESP:00/08908-1
364

Análise de sinais de tomografia por coerência óptica: equação LIDAR e métodos de inversão / Optical coherence tomography signal analysis: LIDAR like equation and inverse methods

AMARAL, MARCELLO M. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:35:36Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:03:59Z (GMT). No. of bitstreams: 1 18318.pdf: 807310 bytes, checksum: 8c5bdd86eba538874949819ad34cf5ba (MD5) / A Tomografia por Coerência Óptica (OCT) baseia-se na propriedade de retroespalhamento dos meios para construir imagens tomográficas do interior das amostras. De maneira similar, a técnica LIDAR (Light Detection and Range) faz uso desta propriedade para determinar as características da atmosfera, em especial o coeficiente de extinção do sinal. Explorar esta similaridade permitiu aplicar métodos de inversão utilizados na técnica LIDAR às imagens OCT, permitindo construir imagens de coeficiente de extinção, resultado inédito até o momento. Este trabalho teve o objetivo de estudar, propor, desenvolver e implementar algoritmos de métodos de inversão do sinal OCT para determinação do coeficiente de extinção em função da profundidade. Foram utilizados três métodos de inversão, da inclinação, do ponto de contorno e da profundidade óptica, com implementação em ambiente LABView® . Estudo dos erros associados aos métodos de inversão foi realizado e, amostras reais (homogêneas e estratificadas) foram utilizadas para análises em uma e duas dimensões. As imagens de coeficiente de extinção obtidas pelo método da profundidade óptica claramente foram capazes de diferenciar o ar da amostra. As imagens foram estudadas empregando PCA e análise de clusters que avaliou a robustez da técnica em determinar o valor do coeficiente de extinção da amostra. Além disso, o método da profundidade óptica proposto foi empregado para estudar a hipótese de que existe correlação entre o coeficiente de extinção do sinal e a desmineralização de esmalte dental durante o processo cariogênico. Com a aplicação desta metodologia foi possível observar a variação do coeficiente de extinção em função da profundidade e sua correlação com a variação da microdureza, além de mostrar que em camadas mais profundas o valor do coeficiente de extinção valor tende ao de um dente sadio, comportando-se da mesma maneira que a microdureza do dente. / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
365

Chironomus sancticaroli: do cultivo em laboratório ao ensaio ecotoxicológico com amostras ambientais de sedimento / Chironomus sancticaroli: culturing in the laboratory and ecotoxicological, test with environmental sediment samples

VIVEIROS, WILLIAM 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:32:59Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:07Z (GMT). No. of bitstreams: 0 / A qualidade do sedimento no estado de São Paulo tem sido caracterizada com o uso, dentre outras linhas de evidência, dos resultados obtidos com ensaios ecotoxicológicos utilizando o anfípoda Hyalella azteca. Protocolos internacionais como os da USEPA, ASTM, OECD e ENVIRONMENT CANADA descrevem procedimentos para o cultivo e realização desses ensaios utilizando também outros organismos bentônicos, como as larvas de inseto do gênero Chironomus sp (Insecta, Diptera). No Brasil, diversos estudos realizados com a espécie Chironomus sancticaroli não contam com metodologia nacional normatizada. Os protocolos descrevem metodologias para ensaios de sensibilidade à substância de referência como garantia da qualidade dos organismos antes de sua utilização, não estabelecendo outras metodologias para o monitoramento de variáveis biológicas em cultivo de organismos-teste ou ainda, critérios de aceitabilidade. Com o intuito de garantir a qualidade desses organismos cultivados em laboratório e adaptar uma metodologia para ensaios com sedimento, foram realizados ensaios para o monitoramento de variáveis biológicas em cultivo, determinação de critérios de aceitabilidade para essas variáveis e ensaios com amostras de rios e reservatórios do estado de São Paulo durante os anos 2006 a 2009. As variáveis sobrevivência, deformidade do mento em organismos cultivados e submetidos ao controle do ensaio, fecundidade, fertilidade e taxa de eclosão, foram monitoradas e o critério de aceitabilidade para cada uma foi estabelecido com base no cálculo do percentil. As variações encontradas nesses resultados sugerem a existência de possíveis interferentes como a qualidade da água de cultivo utilizada e a consangüinidade. Os critérios de aceitabilidade, determinados com base em percentis, servirão de ferramenta para o controle da qualidade dos organismos cultivados sob condições específicas para cada laboratório. A metodologia de ensaio adaptada mostrou bom desempenho, superando o critério de aceitabilidade estabelecido para a sobrevivência dos organismos do controle do ensaio. O quironomídeo apresentou maior sensibilidade quando comparado ao anfípoda comumente utilizado em ensaios com sedimento, enfatizando a existência de diferentes respostas às características físico-químicas do sedimento, associada à biologia de cada organismo, permitindo-se recomendar a utilização conjunta desses organismos na avaliação da qualidade do sedimento. / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
366

Determinação espectrofotometrica de acetato de medroxiprogesterona em medicamento pela reação com Mo (VI) em 'H IND. 2' S'O IND. 4' / Spectrophotometric determination of medroxioprogesterone in pharmaceuticals using a reaction with Mo (VI) in 'H IND. 2' S'O IND. 4'

Pinheiro, Tania Aparecida Lopes 21 November 2006 (has links)
Orientador: Adriana Vitorino Rossi / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-08-09T10:06:34Z (GMT). No. of bitstreams: 1 Pinheiro_TaniaAparecidaLopes_M.pdf: 1079209 bytes, checksum: 7315b8210dfb843979f6a17ba083ed67 (MD5) Previous issue date: 2006 / Resumo: Acetato de medroxiprogesterona (AMP) é um derivado da progesterona que vem sendo usado para contracepção por cerca de 30 milhões de mulheres e também vem aplicado em tratamentos de câncer. Como em alguns casos, AMP gera efeitos colaterais desfavoráveis, sua dosagem deve ser bem controlada. Neste trabalho, foi desenvolvido um método espectrofotométrico para quantificação de AMP em fármacos pela reação com Mo(VI) em meio fortemente ácido. Testes preliminares como avaliação do ponto de fusão e spot test com ácido sulfúrico foram introduzidos para identificar o AMP de outros compostos, como derivados de cortisona que também podem reagir com Mo(VI). A reação foi otimizada a partir da avaliação de algumas variáveis do sistema reacional: tempo e temperatura de aquecimento, solvente e concentração de ácido. Os resultados obtidos indicaram que as melhores condições para o sistema reacional são: solução 9 mol L de H2SO4, 70 minutos de aquecimento a 90 °C e uso de AMP em acetonitrila. Nestas condições, foram obtidas curvas analíticas com a absorbância em 406 nm do produto formado cuja concentração é diretamente proporcional à concentração de AMP na faixa de 5,87x10 a 10,00x10 mg mL, com coeficiente de correlação linear = 0,9972 e limite de detecção = 1,77x10 mg mL. A precisão foi avaliada por intra (repetibilidade) e inter (precisão intermediária) testes, tendo sido obtidos desvios máximos de + 1,9%. Quando comparado com um método de quantificação de AMP em medicamentos comerciais por cromatografia líquida de alta eficiência, os resultados com o método proposto não apresentaram diferenças estatisticamente significativas com 95 % de confiança, indicando bom desempenho do método baseado na reação colorimétrica, que tem favoráveis características de simplicidade instrumental / Abstract: Acetate of medroxiprogesterona (AMP) is one derivative of the progesterone, that have been used used as contraceptive method for about 30 million women. And in treatments of cancer. In some cases, AMP cause favorable collateral effect, therefore its dosage must be well controlled. In this work, a spectrophotometric method for quantification of AMP in pharmaceutical preparation using the reaction with Mo(VI) in strong acid was developed. Preliminary tests as evaluation of the fusing point and spot test with H2SO4 had been introduced in order to identify the AMP from other compounds, as corticoids, that ca also react with Mo(VI). The reaction was optimized from the evaluation of some reaction variable: time and temperature of heating, AMP solvent, acid concentration. The optimized conditions are 9 mol L H2SO4; heating for 70 minutes at 90 °C and acetonirile solvent for AMP. In these conditions, analytical curves of absorbance at 406 nm of the product formed whose concentration is directly proportional to the initial concentration of AMP were obtained from 5,87x10 a 10,00x10 mg mL , with linear coefficient = 0,9972 and detection limit = 1,77x10 mg mL. The precision was evaluated by intra (repeatability) and inter (intermediate precision) tests, having been achieved maximum relative deviation = + 1,9 %. When compared with a HPLC method of quantification of AMP in commercial medicines, the results achieved with this method did give statistical significant differences at 95 % confidence level, indicating good performance of the colorimetric method, which has the advantage of instrumental simplicity / Mestrado / Quimica Analitica / Mestre em Química
367

Conicidade de preparos para coroas totais: acompanhamento de estudantes de Odontologia / Taper preparations for full crowns: monitoring of dental students

Livia Duarte Santos Lopes 29 April 2011 (has links)
A avaliação do processo ensino-aprendizagem constitui uma etapa importante da prática docente que visa interpretar os conhecimentos, habilidades e atitudes dos alunos e proporcionar melhorias nos objetivos educacionais. Com intuito de acompanhar o desempenho de estudantes da Faculdade de Odontologia de Bauru da Universidade de São Paulo na área de Prótese Dentária, a conicidade dos preparos para coroas totais realizados por alunos do segundo ano da graduação: grupo 1 (G1), terceiro ano da graduação: grupo 2 (G2) e pós-graduação: grupo 3 (G3) foi mensurada. Foram avaliados 174 preparos, sendo 112 dentes artificiais preparados por G1, 30 troquéis de dentes preparados por G2 e 32 troquéis de dentes preparados por G3. A conicidade mesio-distal (MD) e vestibulo-lingual (VL) de cada preparo foi medida com auxílio do microscópio digital Dino Capture AM 313T. As médias de conicidade total no sentido mesio-distal (MD) foram, no G1: 11,13° para dentes anteriores e 14,21° para dentes posteriores, G2: 20,47° para dentes anteriores e 21,34° para dentes posteriores e G3: 8,75° para dentes anteriores e 12,54° para dentes posteriores. No sentido vestíbulo-lingual (VL) as médias de conicidade total dos preparos realizados foram no G1: 24,08° para dentes anteriores e 13,8° para dentes posteriores, G2: 25,5° para dentes anteriores e de 21,14° posteriores para dentes posteriores e G3: 16,28° para dentes anteriores e 14,13° para dentes posteriores. Maiores valores de conicidade foram encontrados em preparos realizados pelos alunos do terceiro ano da graduação (22,11°), quando comparados com os ângulos encontrados pelos alunos do segundo ano da graduação (15,80°) e pós-graduação (12,92°). Os resultados oferecem dados à comunidade odontológica internacional para estudos comparativos e possibilitam traçar considerações sobre a transmissão de conhecimento em relação à conicidade de preparos. / The evaluation of teaching-learning process constitutes an important step in teaching practice that seeks to interpret the knowledge, skills and attitudes of students and provide improvements in educational goals. For tracking the students performances from the Dentistry School in Bauru, from the University of São Paulo, in Prosthodontics, the taper for the full crowns preparations made by students of the second year of graduation (G1), the third year of graduation (G2) and postgraduate students (G3) was measured. 174 preparations were assessed, being 112 artificial teeth prepared by G1, 30 stone dies of teeth prepared by G2 and 32 stone dies of teeth prepared by G3. The mesiodistal and faciolingual taper from each preparation was measured with the aid of digital microscope Dino Capture AM 313T. The average total taper towards mesiodistal was G1:11.13° for anterior teeth and 14.21° for posterior teeth, G2: 20.47° for anterior teeth and 21.34 ° for posterior teeth and G3: 8.75° for anterior teeth and 12.54° for posterior teeth. In faciolingual view, the taper averages were for G1: 24.08° for anterior teeth and 13.8° for posterior teeth, G2: 25.5° for anterior teeth and 21.14° for posterior teeth and G3: 16.28° for anterior teeth and 14.13° for posterior teeth. Larger taper values were found in preparations made by the students of the third year of graduation (22.11°), when compared to the angles found by students of the second year (15.80°) and postgraduate students (12.92°). The results provide data for the International Dental community for comparative studies and enable trace considerations about the transmission of knowledge in relation to taper preparations.
368

Avaliação da definição do ângulo cavossuperficial em preparos cavitários realizados com instrumentações rotatória e ultrassônica / Evaluation of cavosurface margin definition in dental cavity preparations made with rotary and ultrasonic instrumentation

Ricardo Virgolino Carvalho da Silva 16 April 2010 (has links)
O objetivo deste estudo foi avaliar a definição do ângulo cavossuperficial em preparos realizados com instrumentações rotatória e ultrassônica com o sistema CVDentUS utilizando potências variadas do aparelho de ultrassom. Quatro cavidades em forma de circunferência foram realizadas na face vestibular de 10 dentes incisivos bovinos, utilizando-se as pontas cilíndricas CVDentUS (n.82137) e diamantada convencional para alta rotação (n.1092). A amostra foi dividida em 4 grupos: G1 Alta rotação; G2 Ultrassom com potência de 30%; G3 Ultrassom com potência de 60%; G4 Ultrassom com potência de 90%. Os preparos realizados foram padronizados medindo aproximadamente 2 mm de diâmetro e 4 mm de profundidade. Os preparos foram examinados em MEV, o que possibilitou avaliar o ângulo cavossuperficial de cada preparo. Cada preparo foi registrado por meio de fotomoicrografias para serem analisados no programa computadorizado Image pró-plus, que permitiu quantificar a área irregular de cada preparo. Os resultados foram analisados com ANOVA (p< 0,00003), verificando-se a significância estatística entre os fatores, foi aplicado o teste de Tukey que demonstrou haver diferenças na área das irregularidades dos preparos avaliados. Com base na metodologia empregada pôde-se concluir que a definição do ângulo cavossuperficial sofre influência relativa em função do tipo de instrumentação, sendo que a instrumentação rotatóra demonstrou similaridade quanto a regularidade marginal dos preparos cavitários quando comparada com a instrumentação ultrassônica utilizada na faixa de 30% da potencia máxima do aparelho, no entanto quando utilizada nas outras potências avaliadas (60 e 90%) houve alterações mais significativas na definição marginal dos preparos cavitários / The aim of this study was to evaluated the definition of the cavosurface margin in cavity preparations made with a high speed dental handpieces (360.000 rpm) and with ultrasonic devices. Four cavities in the form of a circle were performed in a buccal surface of 10 bovine incisor teeth, using cylindrical tips CVDentUS (n.82137) for ultrasound and conventional cylindrical diamond bur (n.1092) for rotary instrumentation. The sample was divided into 4 groups: G1 - High speed, G2 - Ultrasound with power level of 30%, G3 - Ultrasound with power level of 60%, G4 - Ultrasound with power level of 90%. The preparations were standardized measuring approximately 2 mm in diameter and 4 mm in depth. The specimens were examined by SEM to evaluate the cavosurface margin of each preparation. The images were analyzed in a computer program, Image Pro-Plus 4.5, which allowed quantifying the irregular area of each preparation. The results were analyzed by ANOVA (p<0, 00003) showed statistically significant differences. The Tukey test pointed differences in the irregularities areas of the preparations. According to the methodology used, rotary instrumentation showed similarity, as the marginal regularity of dental cavities, compared to ultrasonic instrumentation used in the range of 30%. It was concluded that both instruments are effective for the realization of cavity preparations, however when the powers of 60 and 90% were used, cavity margins showed less defined.
369

Controlled coal blending for power station optimisation

Coventry, Timothy Edward Jan 21 August 2012 (has links)
M.Ing. / Eskom's power stations receive their main supply of coal from mines next to the power stations. The coal supply contracts only specify maximum allowable variations of some coal quality parameters. The quality of the supplied coal can, however, vary greatly within a few hours. The boilers in the power plant are optimized for a certain quality of coal, while the supplied coal is burnt as it is received from the mine. The variations in the coal quality can, therefore, have a negative impact on both the life expectancy and maintenance costs of the power plant as well as the controllability of the boiler. The effects of short term variations in the coal qualities can be reduced by segregating the supplied coal into separate stockpiles according to coal quality parameters such as ash content and volatile matter, and then blending different portions from these stockpiles to a preferred coal quality before the coal goes to the boilers. A self organising feature map neural network was proposed in this research, to determine how to separate the supply coal, according to measured coal quality data. Furthermore, linear programming was proposed to determine the proportions to be taken from each stockpile in order to achieve a more consistent blended coal again. The segregating and blending systems are described in this thesis; and they were tested by means of a simulation based on measured coal quality data from a power station. It was shown that it is possible to successfully segregate coal from a single supply and then blend the different stockpiles to render coal with less short term variations in its quality parameters. The blending process uses stockpile size as its main driver to optimize the selection of the proportions, such that the most coal is taken from the largest stockpile, while the resultant coal quality remains within the specified constraints.
370

Application of Lean Techniques to Reduce Preparation Times: Case Study of a Peruvian Plastic Company

Silva Reyes, Alfredo Jeampiere, Salas Castro, Rosa Fernanda 11 1900 (has links)
This article examines the problem of an increase in product returns for a company that produces plastic films for flexible packaging. Among the factors that have resulted in the increase of returned products are defects in the films caused by the poor manipulation of materials and, above all, the hard point in the coils caused by excessive extruder preparation time, causing the extrusion head to overheat as well as uneven extrusion. Extrusion is a key process in the production of plastic materials as it transforms polypropylene and additives into plastic sheets. The delay in the preparation time caused by machine operators leads to the overheating of the extrusion head and, therefore, defective products that are ultimately returned to the company by customers. In order to confront this problem, a proposal was developed using the SMED tool of Lean Manufacturing in order to reduce the preparation time of the extruder and to increase the productivity of the company. For the validation of the proposal, we simulated the system to determine the resulting reduction in extruder preparation time.

Page generated in 0.1759 seconds