• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 8
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 8
  • 8
  • 5
  • 5
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Traumatismo periodontal em condições normais e modificadas pela administração sistemica do corticosteroide dexametasona : estudo experimental em saguis (Callitherix jacchus)

Sallum, Antonio Wilson, 1943- 20 July 2018 (has links)
Orientador: Aparecido do Nascimento / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-20T12:40:10Z (GMT). No. of bitstreams: 1 Sallum_AntonioWilson_D.pdf: 1802092 bytes, checksum: 09661c1218ecdbb5ada92eb1f1e24c20 (MD5) Previous issue date: 1973 / Resumo: Não informado / Abstract: Not informed. / Doutorado / Periodontia / Doutor em Ciências
2

Determinação de flúor em amostras biológicas e industriais usando espectrometria de absorção molecular de alta resolução com fonte contínua e forno de grafite

Morés, Silvane January 2013 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências Física e Matemáticas. Programa de Pós-Graduação em Química, Florianópolis, 2013 / Made available in DSpace on 2013-12-06T00:37:40Z (GMT). No. of bitstreams: 0 Previous issue date: 2013Bitstream added on 2014-09-24T20:27:43Z : No. of bitstreams: 1 319756.pdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Este trabalho tem como objetivo o desenvolvimento e a aplicação de métodos analíticos que permitem a determinação acurada, sensível e rotineira de flúor em amostras biológicas e industriais. Espectrometria de absorção molecular de alta resolução com fonte continua foi utilizado para a elaboração da técnica de determinação de flúor utilizando mono-fluoreto de cálcio, CaF, em comprimento de onda de 603,690 nm e de 606,440 nm, e também mono-fluoreto de gálio, GaF, no comprimento de onda 211,428 nm. Em amostras de creme dental, a determinação de flúor, via GaF, em forno de grafite, com temperatura de pirólise de 550 ºC e a temperatura de vaporização de 1550 ºC, a curva de calibração foi linear no intervalo entre 1 ? 50 µg/L, limite de detecção de 0,26 µg/L. Os valores para flúor encontrados em 10 amostras de creme dental foram condizentes com os valores informados pelos fabricantes. Cromatografia a gás acoplada à espectrometria de massas foi utilizada como uma técnica alternativa para a comparação dos dados obtidos, e os dois métodos não mostraram estatisticamente diferenças entre os resultados. Para a determinação de flúor em amostras de chá, via CaF, em forno de grafite, com temperatura de pirólise de 725 ºC e a temperatura de vaporização de 2100 ºC, a curva de calibração foi linear no intervalo entre 0,5 - 25 mg/L, com um coeficiente de correlação de R = 0,9994 e limite de detecção de 0,16 mg/L. Os valores para flúor encontrados em 10 amostras comerciais de chá variaram entre 42 mg/g e 87 mg/g; as infusões desses chás continham entre 21 mg/g e 56 mg/g F, o que significa um percentual de extração entre 48% e 74%. Para a determinação de flúor em amostras de saliva, via CaF, também utilizou-se a cromatografia a gás acoplada à espectrometria de massas como uma técnica comparativa, e mais uma vez os dois métodos mostraram-se eficazes. A concentração de flúor logo após a escovação é de cerca de 29 mg/L. Depois de 5 minutos, a concentração diminui cerca de 90% e, após 30 minutos, está abaixo do limite de quantificação. <br> / Abstract: This work is based on the development and application of an analytical method that enables an accurate, sensitive, routine determination of fluorine in biological and industrial samples. High-resolution continuum source graphite furnace molecular absorption spectrometry was used for the determination of fluorine using calcium mono-fluoride, CaF, at the wavelengths of 603.690 nm and 606.440 nm, and also gallium mono-fluoride, GaF, at a wavelength of 211.428 nm. In samples of toothpaste, determining fluorine via GaF with a pyrolysis temperature of 550 °C and an vaporization temperature of 1550 °C, the calibration curve was linear in the range between 1 - 50 µg/L and the limit of detection was 0.26 µg/L. The values for fluoride found in 10 samples of toothpaste were consistent with the values reported by the manufacturers. Gas chromatography coupled to mass spectrometry (GC-MS) was used as an alternative technique for comparing the data, and the two methods showed no statistical difference between the results. For the determination of fluorine in tea samples via CaF, with a pyrolysis temperature of 725 °C and a vaporization temperature of 2100 °C, the calibration curve was linear within the range of 0.5 - 25 mg/L, with a correlation coefficient of R = 0.9994 and a limit of detection of 0.16 mg/L. The fluorine values found for 10 samples of commercial tea ranged between 42 mg/g and 87 mg/g; infusions of these same tea samples contained between 21 mg/g and 56 mg/g F, which means a percentage of extraction between 48% and 74%. For the determination of fluorine in saliva samples, via CaF, GCMS was also used as a comparative technique, and the two methods proved effective. The fluoride concentration just after brushing is about 29 mg/L. After 5 minutes, the concentration decreases by about 90% and after 30 minutes it was below the limit of quantification.
3

Efeito de diferentes métodos de higienização sobre a rugosidade superficial de materiais restauradores CAD/CAM /

Castro, Camila Lebre de January 2019 (has links)
Orientador: Edson Alves de Campos / Resumo: A cerâmica é uma opção que preenche as exigências estéticas, biológicas, mecânicas e funcionais de um material restaurador. O sistema CAD/CAM empregado na Odontologia permite confeccionar restaurações indiretas, em um curto período de tempo, cimentá-las na mesma sessão clínica, sem a intermediação do laboratório de prótese. Qualquer material restaurador está sujeito a desgastes por ação da mastigação e a escovação diária. Protocolos de higienização profissional devem ser estabelecidos de maneira a não afetarem a rugosidade superficial das restaurações. O objetivo deste estudo foi avaliar a rugosidade superficial (Ra) de materiais restauradores CAD/CAM após diferentes métodos de higienização. Trata-se de um estudo in vitro que utilizou espécimes (n=144) dos seguintes materiais: Cerâmica Feldspática (Cerec Blocs, Dentsply Sirona); Cerâmica Feldspática reforçada por Leucita (IPS Empress CAD, Ivoclar Vivadent); Cerâmica Di-silicato de lítio (IPS e-max CAD, Ivoclar Vivadent) e Compósito nano híbrido (Grandio Blocs, Voco), sendo que dois materiais, Cerâmica Feldspática e Cerâmica Feldspática reforçada por Leucita foram avaliados com e sem glaze. Os espécimes foram submetidos a três diferentes métodos de higienização (escovação simulada; jato de bicarbonato de sódio e profilaxia com taça de borracha e pasta profilática). A rugosidade superficial foi mensurada antes e após os diferentes métodos de higienização por meio do rugosímetro de contato. A análise de variância foi feita para ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Dental ceramic has been a restorative material option that may provide the aesthetic, biological, mechanical and functional requirements. CAD/CAM (computer aided design/computer aided manufacturing) system used in Dentistry allows to perform indirect restorations in a short period of time and proceed the cementation in the same clinical session without the intermediation of prosthesis laboratory. However, any restorative material can wear due to chewing and daily toothbrushing action. Thus, hygiene protocols should be stated in order to not affect the surface roughness of restorations. This study aimed to evaluate the surface roughness (Ra) of CAD/CAM restorative materials after different hygiene protocols. This in vitro study used the following materials (n=144): Feldspathic ceramic (Cerec Blocs, Dentsply Sirona); Leucite-reinforced feldspathic ceramic (IPS Empress CAD, Ivoclar Vivadent); Lithium disilicate ceramic (IPS e-max CAD, Ivoclar Vivadent) and Nanohybrid resin-based composite (Grandio Blocs, Voco). For Feldspathic ceramic and Leucite-reinforced feldspathic ceramic it was performed the evaluations with and without glaze. The samples were submitted to three different hygiene protocols (simulated brushing, sodium bicarbonate jet and prophylaxis with rubber cup and prophylactic paste). Surface roughness was measured before and after the hygiene protocols by a contact rugosimeter. ANOVA test was applied to evaluate the initial roughness among materials, followed by Games... (Complete abstract click electronic access below) / Mestre
4

Estudo da rugosidade e ultra-estrutura superficial do esmalte dental humano submetido a diferentes métodos profiláticos /

Castanho, Gisela Muassab. January 2007 (has links)
Orientador: Marcelo Fava / Banca: Antonio Alberto de Cara / Banca: Rebeca Di Nicoló / Resumo: Este trabalho teve como propósito estudar a rugosidade e ultra-estrutura superficial in vitro do esmalte dental humano submetido a três métodos profiláticos. Selecionaram-se 69 molares humanos com faces vestibulares hígidas e divididos em três grupos. No primeiro grupo, utilizou-se uma mistura de pedra-pomes (SSWhite) e água destilada com o auxílio de taça de borracha, montadas em contra-ângulo; no segundo, pasta profilática Herjos-F (Vigodent), taça de borracha e contra-ângulo e no terceiro, jato de bicarbonato com o aparelho Profi II Ceramic (Dabi Atlante). Todos os procedimentos foram realizados pelo mesmo operador durante 10 s, lavados e armazenados em água destilada. As mensurações da rugosidade superficial, em æm, foram realizadas antes e após os procedimentos com o aparelho Perthomether S8P em 54 amostras e o restante foram metalizadas e avaliadas por meio de MEV. Os resultados obtidos pelas leituras no rugosímetro foram submetidos à análise estatística através do teste t (Student) de pares equiparados e o teste de Kruskal-Wallis associado ao teste de comparação múltipla de Dunn (5%). Pôde-se observar que a rugosidade superficial do esmalte humano obtida pelo tratamento com o jato de bicarbonato mostrou-se maior de maneira estatisticamente significante quando comparada àquela obtida com a pedrapomes, enquanto que a utilização da pasta profilática não apresentou diferenças estatisticamente significantes em relação à utilização dos outros dois métodos. Na avaliação ultra-estrutural, observou-se a presença de inúmeros grânulos com diâmetros variados e depressões acentuadas nas superfícies tratadas com o jato de bicarbonato. Concluiu-se que o jato de bicarbonato aumentou a rugosidade superficial quando comparado à pedrapomes. / Abstract: The purpose of this in vitro study was to evaluate alterations in the surface roughness and micromorphology of human enamel submitted to three prophylaxis methods. Sixty nine caries-free molars with exposed labial surfaces were divided into three groups. The first group was treated with a rotary instrument set at a low speed, rubber cup and a mix of water and pumice slurry; the second, a rotary instrument set at a low speed, rubber cup and prophylaxis paste Herjos-F (Vigodent) and the third group, jet abrasive system with sodium bicarbonate Profi II Ceramic (Dabi Atlante). All procedures were performed by the same operator for 10 s, and samples were rinsed and stored in distilled water. Pre and post-treatment surface evaluation was completed using a surface profilometer (Perthomether S8P) in 54 samples. In addition, the other samples were coated with gold and examined in a scanning electron microscope (SEM). The results of this study were statistically analyzed with paired t-test (Student), Kruskal-Wallis test and Dunn (5%) test. The treatment with sodium bicarbonate jet significantly increased the human enamel surface roughness when compared with that of pumice paste. The use of prophylaxis paste Herjos-F, however, showed no statistically significant difference when compared with the other methods. Based on micromorphology analysis, the sodium bicarbonate jet presented an irregular surface with granular material and erosions. Based on this study, it could be concluded that there was increased enamel surface roughness when a tooth was treated with sodium bicarbonate jet when compared with pumice paste. / Mestre
5

Remoção de irregularidades superficiais do esmalte dental após a remoção de braquetes ortodônticos : efeito de polimentos superficiais e tempos de análise /

Franco, Laura Molinar. January 2017 (has links)
Orientador: Renato Herman Sundfeld / Coorientador: Lucas Silveira Machado / Banca: André Pinheiro de Magalhães Bertoz / Banca: Sergio Kiyoshi Ishikiriama / Banca: Elaine Cristina Guerbach Conti / Banca: Rodolfo Brunieira Anchieta / Resumo: O objetivo deste ensaio clínico foi avaliar o comportamento de dois sistemas de polimento na regularização da superfície do esmalte dental, que apresentava-se rugosa e irregular após a remoção de braquetes ortodônticos. As variáveis de resposta foram: rugosidade superficial, luminosidade, morfologia, textura e sensibilidade. Fizeram parte dessa pesquisa clínica 30 voluntários. Os fatores em estudo foram: as técnicas de poli- mento superficial em dois níveis: Técnica 1 (discos de óxido de alumínio) e Técnica 2 (produto ácido-abrasivo), e o tempo de análise em 5 níveis: T0 (baseline), T1 (imedia- tamente após os polimentos superficiais), T2 (após polimento final), T3 (7 dias após os procedimentos) e T4 (6 meses após os procedimentos). Os dados representados por escores foram analisados considerando distribuição multinomial; os dados numéricos foram analisados como medidas repetidas no tempo, a um nível de significância de 5%. Nas análises de rugosidade superficial e luminosidade, não houve diferença estatística entre as técnicas em todos os tempos analisados. Nas análises por score, dentro de cada tempo, verificou-se igualdade significativa apenas no baseline; nos demais tempos foram observadas irregularidades superficiais estatisticamente superiores para a Técnica 1. Nenhum paciente apresentou sensibilidade dental. Ambas as técnicas foram eficientes; porém a maior lisura foi adquirida quando a Técnica 2 foi utilizada. / Abstract: This clinical study evaluated the behavior of two surface polishing systems in the regularization of the enamel surface, which was rough and irregular after orthodontic brackets debonding. The response variables were: surface roughness, lightness, morphology, texture and sensitivity. Thirty volunteers were part of this clinical research. The factors under study were: Surface polishing at two levels: Technique 1 (aluminum oxide disks) and Technique 2 (enamel microabrasive product); and the Time of analysis at 5 levels: T0 (after surface polishing), T1 (immediately after surface polishing), T2 (after final polishing), T3 (7 days after surface polishing) and T4 (6 months after surface polishing). The data represented by scores were analyzed considering multinomial distribution; the numerical ones were analyzed as measures repeated in time, at a significance level of 5%. In the analysis of surface roughness and lightness, there was no statistical difference between the polishing techniques at all times analyzed. In the other analyzes, within each time, significant equality was observed only in the baseline, while in the other times superficial irregularities were statistically superior for Technique 1. No patient presented dental sensitivity. Both techniques were efficient; however, the higher surface smoothness was observed on the dental enamel surface polished with the Technique 2 / Doutor
6

Estudo da rugosidade e ultra-estrutura superficial do esmalte dental humano submetido a diferentes métodos profiláticos

Castanho, Gisela Muassab [UNESP] 21 March 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-03-21Bitstream added on 2014-06-13T19:07:25Z : No. of bitstreams: 1 castanho_gm_me_sjc.pdf: 1475758 bytes, checksum: c907f9b0250122090a0d2fa504363658 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este trabalho teve como propósito estudar a rugosidade e ultra-estrutura superficial in vitro do esmalte dental humano submetido a três métodos profiláticos. Selecionaram-se 69 molares humanos com faces vestibulares hígidas e divididos em três grupos. No primeiro grupo, utilizou-se uma mistura de pedra-pomes (SSWhite) e água destilada com o auxílio de taça de borracha, montadas em contra-ângulo; no segundo, pasta profilática Herjos-F (Vigodent), taça de borracha e contra-ângulo e no terceiro, jato de bicarbonato com o aparelho Profi II Ceramic (Dabi Atlante). Todos os procedimentos foram realizados pelo mesmo operador durante 10 s, lavados e armazenados em água destilada. As mensurações da rugosidade superficial, em æm, foram realizadas antes e após os procedimentos com o aparelho Perthomether S8P em 54 amostras e o restante foram metalizadas e avaliadas por meio de MEV. Os resultados obtidos pelas leituras no rugosímetro foram submetidos à análise estatística através do teste t (Student) de pares equiparados e o teste de Kruskal-Wallis associado ao teste de comparação múltipla de Dunn (5%). Pôde-se observar que a rugosidade superficial do esmalte humano obtida pelo tratamento com o jato de bicarbonato mostrou-se maior de maneira estatisticamente significante quando comparada àquela obtida com a pedrapomes, enquanto que a utilização da pasta profilática não apresentou diferenças estatisticamente significantes em relação à utilização dos outros dois métodos. Na avaliação ultra-estrutural, observou-se a presença de inúmeros grânulos com diâmetros variados e depressões acentuadas nas superfícies tratadas com o jato de bicarbonato. Concluiu-se que o jato de bicarbonato aumentou a rugosidade superficial quando comparado à pedrapomes. / The purpose of this in vitro study was to evaluate alterations in the surface roughness and micromorphology of human enamel submitted to three prophylaxis methods. Sixty nine caries-free molars with exposed labial surfaces were divided into three groups. The first group was treated with a rotary instrument set at a low speed, rubber cup and a mix of water and pumice slurry; the second, a rotary instrument set at a low speed, rubber cup and prophylaxis paste Herjos-F (Vigodent) and the third group, jet abrasive system with sodium bicarbonate Profi II Ceramic (Dabi Atlante). All procedures were performed by the same operator for 10 s, and samples were rinsed and stored in distilled water. Pre and post-treatment surface evaluation was completed using a surface profilometer (Perthomether S8P) in 54 samples. In addition, the other samples were coated with gold and examined in a scanning electron microscope (SEM). The results of this study were statistically analyzed with paired t-test (Student), Kruskal-Wallis test and Dunn (5%) test. The treatment with sodium bicarbonate jet significantly increased the human enamel surface roughness when compared with that of pumice paste. The use of prophylaxis paste Herjos-F, however, showed no statistically significant difference when compared with the other methods. Based on micromorphology analysis, the sodium bicarbonate jet presented an irregular surface with granular material and erosions. Based on this study, it could be concluded that there was increased enamel surface roughness when a tooth was treated with sodium bicarbonate jet when compared with pumice paste.
7

Estudo da rugosidade e da morfologia superficial do esmalte de dentes decíduos submetidos a diferentes métodos profiláticos /

Oliveira Netto, Arlindo Carvalho. January 2018 (has links)
Orientador: João Carlos Rocha / Coorientador: Ivan Balducci / Banca: João Paulo Barros Machado / Banca: José Benedito Oliveira Amorim / Resumo: O controle da doença cárie é um dos maiores desafios na Odontologia. O controle do biofilme, de forma mecânica pelo paciente ou pelo profissional, ainda é o melhor método preventivo Este trabalho tem como objetivo a realização de um estudo in vitro da rugosidade do esmalte de dentes decíduos submetidos a quatro métodos profiláticos diferentes. Selecionamos 32 faces proximais de dentes decíduos hígidos, que foram divididos em 4 grupos. No primeiro grupo utilizamos para o polimento mistura de pedra-pomes (SSWHITE)® e água destilada e realizamos polimento utilizando taça de borracha em caneta de baixa rotação; no segundo, pasta profilática Clinpro Prophy Paste (3M)®também com taça de borracha em caneta de baixa rotação; no terceiro jato de bicarbonato de sódio (Polident) e no quarto jato de glicina Clinpro Prophy Powder(3M). Todos os procedimentos foram realizados pelo mesmo operador, que foi calibrado na busca de reprodução de situação clínica. Em cada espécime os procedimentos foram realizados durante 10 segundos com os produtos e equipamentos determinados. Após os procedimentos profiláticos os dentes foram lavados e armazenados em água destilada até o momento das leituras. As leituras para mensuração da rugosidade superficial em micrometros foram realizadas antes e após os procedimentos profiláticos por meio do Perfilômetro Óptico Wyko NT1100 INPE. Todos os grupos provocaram um aumento do valor de Rugosidade aritmética Ra, que é a rugosidade provocada por picos e vale do esmalte de dentes decíduos, sendo que o grupo 4 do (bicarbonato) que apresentou melhores resultados por apresentar menor variação em analise estatísticas, através da ferramenta teste t-Student mostrou que não houve variação de Ra inicial entre os 4 grupos / Abstract: Caries disease control is one of the greatest challenges in dentistry. The biofilm control mechanically by the patient or by the professional is still the best preventive method. This work aims to perform an in vitro study of the enamel roughness of deciduous teeth submitted to four different prophylactic methods. We selected 32 faces close to healthy deciduous teeth, which were divided into 4 groups. In the first group we used a mixture of pumice (SSWHITE) ® and distilled water polishing with rubber cup in a low rotation pen; in the second group we used Clinpro Prophy Paste (3M) ® prophylactic paste also with rubber cup in low rotation pen, in the third group the polishing with sodium bicarbonate jet (Polident) and in the fourth group with glycine jet Clinpro Prophy Powder (3M ). All procedures were performed by the same operator properly calibrated for 10 seconds with parameters controlled after the prophylactic procedures the teeth were washed and stored in distilled water until readings. The readings for measuring surface roughness in micrometers will be performed before and after the prophylactic procedures using the Wyko NT1100 INPE apparatus obtaining the Ra value. All the prophylactic methods caused an increase in the Ra value, with the bicarbonate group 4 having the best results in statistical analysis the tStudent test tool and there was no initial Ra variation among the 4 groups / Mestre
8

Avaliação da rugosidade do esmalte dental apos microabrasão e polimento e da microdureza superficial apos microabrasão, polimento e armazenamento em saliva artificial / Evaluation of the enamel roughness after microabrasion and polishing and the superficial microhardness after microabrasion, polishing and storage in artificial saliva

Fragoso, Larissa Silveira de Mendonça 02 September 2010 (has links)
Orientador: Jose Roberto Lovadino / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-15T04:10:10Z (GMT). No. of bitstreams: 1 Fragoso_LarissaSilveiradeMendonca_D.pdf: 5875751 bytes, checksum: fa7d309c1cc22de111d7f7c71f8d04c5 (MD5) Previous issue date: 2010 / Resumo: Os objetivos deste estudo "in vitro" foram: 1) avaliar o efeito da microabrasão sobre a microdureza e a rugosidade do esmalte dental bovino, bem como a ação do polimento realizado com pastas apropriadas no esmalte abrasionado; 2) avaliar o armazenamento em saliva artificial, em diferentes tempos de ação sobre a microdureza do esmalte dental bovino. Para isso, foram utilizados 144 blocos de esmalte bovino (6,0mm x 6,0mm) que constituíram os grupos: I- tratamento com ácido fosfórico a 37% e pedra pomes (n=48), II- tratamento com Opalustre (Ultradent) (n=48), III- tratamento com Whiteness RM (FGM) (n=48). Os três grupos foram divididos em três subgrupos, de acordo com os seguintes tratamentos: a) polimento com pasta diamantada; b) polimento com pasta profilática fluoretada e c) sem polimento (controle). Foram realizados ensaios de microdureza nos seguintes tempos estabelecidos: 1) inicial (antes da realização da microabrasão e polimento); 2) após a realização da microabrasão com e sem polimento; 3) após a realização da microabrasão com e sem polimento e imersão em saliva artificial por períodos de 24 horas; 4) após a realização da microabrasão com e sem polimento e imersão em saliva artificial por 7 dias. Foram realizados ensaios de rugosidade nos seguintes tempos pré-estabelecidos: 1) inicial (antes da realização da microabrasão e polimento) e final (após a realização da microabrasão com e sem polimento (controle). Os dados obtidos foram submetidos à análise estatística ANOVA "dois fatores", e teste de Tukey com significância de 5% para microdureza e rugosidade. Os resultados mostraram que a microabrasão seguida de polimento proporcionou aumento de microdureza superficial; quando não se utilizou polimento, somente os sistemas microabrasivos com ácido clorídrico e carbeto de silício apresentaram aumento da microdureza superficial; os diferentes tempos de armazenamento em saliva artificial não resultaram em aumento da microdureza superficial; os produtos utilizados para microabrasão não proporcionaram rugosidade superficial diferentes entre si; todos os sistemas microabrasivos seguidos de polimento apresentaram maior lisura superficial quando comparados aos grupos sem polimento. Baseado nos resultados obtidos, conclui-se que a microabrasão seguida de polimento, proporcionou maior dureza e maior lisura de superfície do esmalte dental. A imersão em saliva artificial por períodos de 24 horas e 7 dias, contudo, não alterou a dureza do esmalte dental. / Abstract: The objectives of this study in vitro were: 1) evaluate the effect of microabrasion on microhardness and roughness of bovine enamel and the action of polishing carried out with the appropriate pastes on abrasioned enamel, 2) evaluate the effect of storage in artificial saliva, during different times of action, on the microhardness of bovine dental enamel. For this, used 144 bovine enamel blocks (6.0 mm x 6.0 mm), forming the groups: I-treatment with 37% phosphoric acid and pumice paste (n = 48), Il-treatment with Opalustre (Ultradent) (n = 48), Ill-treatment with Whiteness RM (FGM) (n = 48). Then the three groups were divided into three subgroups, according to the following treatments: a) diamond polishing paste, b) polishing with fluoride prophylactic paste and c) without polishing (control). Tests of hardness were carried out in the following set times: 1) initial (prior to the microabrasion and polishing), 2) after microabrasion with and without polishing (control), 3) after microabrasion with and without polishing and immersion in artificial saliva for 24 hours; 4) after microabrasion with and without polishing and immersion in artificial saliva for 7 days. Tests of surface roughness were performed in the following pre-set times: 1) initial (prior to the microabrasion and polishing) and final (after the completion of microabrasion with and without polishing) (control). The obtained data were analyzed by "two factors" ANOVA and Tukey test with significance of 5% for hardness and roughness. The results showed that: microabrasion followed by polishing provided an increase of superficial microhardness; without the use of polishing, only the microabrasive systems with hydrochloric acid and silicon carbide showed increased superficial microhardness; different times of storage in artificial saliva did not result in increased microhardness; the products used for microabrasion did not provide surface roughness different from each other; all microabrasive systems followed by polishing showed a higher surface smoothness compared with the groups without polishing. Based on these results, it can be inferred that microabrasion followed by polishing provided higher hardness and better surface smoothness of the dental enamel. However, the immersion in artificial saliva for 24 hours and 7 days was not able to increase the enamel hardness. / Doutorado / Dentística / Doutor em Clínica Odontológica

Page generated in 0.0626 seconds