• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 216
  • 5
  • 4
  • 4
  • 4
  • 4
  • 3
  • 1
  • Tagged with
  • 223
  • 223
  • 223
  • 133
  • 119
  • 95
  • 62
  • 61
  • 53
  • 41
  • 35
  • 34
  • 31
  • 31
  • 29
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
221

Modelo de gerenciamento de usos múltiplos da água: um estudo de caso para a bacia hidrográfica do rio Tapajós

FIGUEIREDO, Nelio Moura de 02 1900 (has links)
Submitted by Nathalya Silva (nathyjf033@gmail.com) on 2017-04-24T20:04:12Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_ModeloGerenciamentoAgua.pdf: 11144827 bytes, checksum: 1729da6214c18fcd59e89f3ba710e78e (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-04-26T13:22:34Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_ModeloGerenciamentoAgua.pdf: 11144827 bytes, checksum: 1729da6214c18fcd59e89f3ba710e78e (MD5) / Made available in DSpace on 2017-04-26T13:22:34Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_ModeloGerenciamentoAgua.pdf: 11144827 bytes, checksum: 1729da6214c18fcd59e89f3ba710e78e (MD5) Previous issue date: 2016-02 / Este trabalho trata de um modelo para gerenciamento de usos múltiplos da água, visando minimizar conflitos de uso, relacionados com a operação de sistemas de reservatórios em aproveitamentos hidrelétricos de bacias hidrográficas. O modelo SOUMA – “Sistema de Otimização de Usos Múltiplos da Água”, que consiste em um modelo estocástico de otimização baseado em programação não linear, foi desenvolvido e estruturado em GAMS (General Algebraic Modeling System) com o emprego do solver MINOS. O SOUMA compõe-se de dois módulos auxiliares. O primeiro é um módulo de previsão de níveis de água, que consiste em um modelo estocástico do tipo ARIMA (Auto Regressive Integrated Moving Average). O segundo é um módulo de previsão de vazões, que é um modelo estocástico chuva-vazão, do tipo RNA. O modelo ARIMA na calibração e na validação apresentou R² médio acima de 0,93 e RMSE abaixo de 0,08, capturando de forma satisfatória o comportamento das séries níveis d’água. O modelo chuva-vazão que foi empregado na composição da vazão afluente ao reservatório, com a utilização de arquitetura RNA, apresentou R² médio de 0,954 e RMSE médio de 0,098. O modelo SOUMA foi aplicado à bacia do rio Tapajós para o futuro Aproveitamento Hidro Energético – AHE São Luiz do Tapajós, Itaituba, PA. Foram criados seis cenários que serviram de parâmetros na otimização e minoração dos conflitos. Vazões afluentes ao reservatório foram obtidas e simuladas, para os cenários hidrológicos seco, médio e úmido e para os cenários climáticos El Niño, Neutro e La Niña. Para geração de energia e profundidade de navegação, considerando as afluências dos cenários hidrológicos seco, médio e úmido, o SOUMA evidenciou, em relação aos níveis de referência dos cenários de navegação baixo, médio e alto, a ocorrência de profundidades abaixo da mínima, para gerações médias abaixo de 2.411 MW, 2.939 MW e 3.586 MW, respectivamente. Para geração de energia e capacidade de carga transportada, considerando as afluências dos cenários hidrológicos seco, médio e úmido, o SOUMA demonstrou, em relação aos níveis de referência dos cenários de navegação baixo, médio e alto, que gerações médias acima de 2.869 MW, 3.508 MW e 4.740 MW, respectivamente, não geram ganhos de capacidade de carga transportada e que gerações médias abaixo de 1.344 MW, 1.622 MW 2.056 MW, respectivamente, inviabilizam o transporte de carga. Para geração de energia e cota de inundação, considerando as afluências dos cenários hidrológicos seco, médio e úmido, o SOUMA mostrou, em relação aos níveis de referência dos cenários de controle de inundação baixo, médio e alto, a ocorrência de inundações a jusante, para gerações médias acima de 4.978 MW, 6.057 MW e 7.390 MW, respectivamente. Retiradas consuntivas são significativas apenas no período de junho a outubro. Considerando a média das demandas consuntivas mensais (145 m³/s), para afluências do cenário hidrológico seco, médio e úmido, o SOUMA evidenciou uma perda mensal na geração de energia elétrica de 50 MW, 47 MW e 44 MW, respectivamente. Os resultados aferidos evidenciam que os modelos desenvolvidos são ferramentas de fundamental importância à otimização operacional de sistemas de reservatórios com usos múltiplos, permitindo a otimização de gerações e de defluências em AHE, em períodos de cheia e de estiagem e de grandes demandas energéticas, com a manutenção de condições de navegabilidade em trechos a jusante de barramentos, através de simulações operacionais sustentáveis que minoram conflitos de uso. / This work deals with a model for management of multiple uses of water, for the mitigation of conflicts of use related to the operation of reservoir systems in hydroelectric power plant of water catchment area. The model SOUMA – "system optimization of multiple uses of water", which consists of a stochastic optimization model based on nonlinear programming, was developed and structured in GAMS (General Algebraic Modeling System) with the use of solver MINOS. The SOUMA is composed of two modules. The first is a module for forecasting of water levels, which consists of a stochastic model of type ARIMA (Auto Regressive Integrated Moving Average). The second is a module for forecasting of streamflow, which is a stochastic model of rainfall-streamflow the RNA type. The ARIMA model calibration and validation presented average R² above 0.93 and RMSE below 0.08, capturing in a satisfactory manner the behavior of water levels. The rain-flow model that was used in the composition of influent flow to the reservoir, with the use of RNA architecture, presented average R² 0.954 and of 0.098 RMSE. The SOUMA model was applied to Tapajós River basin for the future hydroelectric power plant of São Luiz do Tapajós, Itaituba, PA. Six scenarios were created to be used as parameters in optimizing and mitigation of conflicts. The reservoir tributaries streamflow were obtained and simulated for dry, medium and moist hydrological scenarios and for El Niño, La Niña and Neutral climatic scenarios. For the power generation and navigation depth uses, considering the tributaries streamflow of the dry, medium and moist hydrological scenarios, the SOUMA showed, in relation to the reference levels of the low, medium and high navigation scenarios, the occurrence of depths below the minimum, for generations averages below 2,411 MW, 2,939 MW and 3,586 MW, respectively. For power generation and cargo capacity, considering the tributaries streamflow of the dry, medium and moist hydrological scenarios, the SOUMA showed, in relation to the low, medium and high reference levels of the navigation scenarios, that generations averages above 2,869 MW, 3,508 MW and 4,740 MW, respectively, do not generate earnings of cargo capacity and that medium generations below 1,344 MW, 2,056 MW and 1,622 MW, respectively, make the river transport of cargo infeasible. For power generation and flood dimension, considering the tributaries streamflow of the dry, medium and moist hydrological scenarios, the SOUMA showed, in relation the reference levels low, medium and high of the flood control, the occurrence of floods downstream to generations above average 4,978 MW, 6,057 MW and 7,390 MW, respectively. Consumptive withdrawals are meaningful only in the period from June to October. Considering the monthly average consumptive demands (145 m ³/s), to tributaries streamflow of the dry, medium and moist hydrological scenarios, the SOUMA showed a monthly loss in power generation of 50 MW, 47 MW and 44 MW, respectively. The measured results show that the models developed are important tools to operational optimization of reservoir systems with multiple uses, allowing the optimization of generations and defluente flow in the hydroelectric power plant of water catchment area, in periods of flood and drought and large energy demands, with maintenance of navigation conditions downstream from dams, through sustainable operational simulations that minimize usage conflicts.
222

Planejamento da expansão de sistemas de transmissão considerando análise de confiabilidade e incertezas na demanda futura

Garcés Negrete, Lina Paola [UNESP] 25 February 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:30:50Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-02-25Bitstream added on 2014-06-13T19:19:30Z : No. of bitstreams: 1 garcesnegrete_lpg_dr_ilha.pdf: 1723635 bytes, checksum: ec9b369023c0d16cf9bcbe29a4bc0ada (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Nessa pesquisa tem-se por objetivo a análise teórica e a implementação computacional de duas propostas de solução ao problema de planejamento da expansão de sistemas de transmissão de energia elétrica considerando diferentes fatores relacionados com a confiabilidade do sistema e a adoção dos novos modelos de mercados elétricos. É importante notar, que no planejamento básico não são levados em conta esses importantes aspectos. Dessa forma, uma primeira aproximação considera um critério de confiabilidade para expandir o sistema, de forma que ele opere adequadamente no horizonte de planejamento satisfazendo um nível de confiabilidade pré-definido. O índice de confiabilidade utilizado para exigir esse nível de confiabilidade é o LOLE, que corresponde ao número médio de horas/dias em um período dado (normalmente um ano) no qual o pico da carga horária/diária do sistema possivelmente exceder´a a capacidade de geração disponível. O problema de planejamento considerando a confiabilidade é, portanto, formulado como um problema de otimização que minimiza o investimento sujeito ao critério de confiabilidade. O índice de confiabilidade para o sistema de transmissão é calculado para cada configuração, subtraindo o índice de confiabilidade do sistema de geração do sistema composto geração-transmissão (bulk power system ). Para calcular o índice no sistema composto geração transmissão, utiliza-se uma curva de duração de carga efetiva para este sistema. Esta curva acumulada de carga é obtida de um processo de convolução de outras duas curvas que representam a função de distribuição de probabilidade (FDP) das saídas aleatórias dos componentes do sistema e a curva de duração de carga, respectivamente. A avaliação de confiabilidade no sistema de geração é feita usando um método que calcula o índice de confiabilidade por meio dos momentos... / This work aims to the theoretical analysis and computational implementation of two proposals for the transmission expansion planning problem considering several factors such as system reliability and new electricity market structures. It is important to observe, that the basic planning does not consider these issues. Therefore, one first approach considers a reliability criterion to expand the system, so that it operates in adequate conditions in the horizon planning while satisfying pre-defined limits in the reliability index. Transmission system reliability criterion regards to LOLE, which refers to the number of hours/days in a specified period of time (normally one year), in which the hourly/daily peak load possibly will exceed the available generation capacity. So, the planning problem considering reliability is formulated as an optimization problem that minimizes the investment subject to probabilistic reliability criterion. Reliability index for the transmission system is calculated for each configuration by subtraction of generation and bulk power reliability indexes. A composite power system effective load curve is used for reliability analysis of the bulk power system. This accumulate curve is obtained convolving two curves, one of them corresponding to a probability distribution function of the random outages of the system components, and the other one corresponding to the load duration curve. Reliability assessment in the generation system is done using a method that calculates the reliability index through the statistics moments of the frequency distribution of equivalents loads. This curve is obtained by convolving the generation units which are dispached in merit order. The proposed model is solved using the specialized genetic algorithm of Chu-Beasley (AGCB). Detailed results on two test systems are analyzed and discussed. A second approach to the transmission expansion... (Complete abstract click electronic access below)
223

Metodologia de otimização de redes malhadas através da programação não linear. / Methodology of network optimization through nonlinear programming.

FORMIGA, Klebber Teodomiro Martins. 10 November 2018 (has links)
Submitted by Johnny Rodrigues (johnnyrodrigues@ufcg.edu.br) on 2018-11-10T14:15:57Z No. of bitstreams: 1 KLEBBER TEODOMIRO MARTINS FORMIGA - DISSERTAÇÃO PPGECA 1999..pdf: 16389709 bytes, checksum: 2cbf1a8342d988c0e6828ecd2fda1b6c (MD5) / Made available in DSpace on 2018-11-10T14:15:57Z (GMT). No. of bitstreams: 1 KLEBBER TEODOMIRO MARTINS FORMIGA - DISSERTAÇÃO PPGECA 1999..pdf: 16389709 bytes, checksum: 2cbf1a8342d988c0e6828ecd2fda1b6c (MD5) Previous issue date: 1999-03-11 / CNPq / As redes de distribuição, que fazem parte dos sistemas de abastecimento de água, são, em grande parte, redes malhadas, cuja complexidade no dimensionamento tem forçado os projetistas a utilizar metodologias tradicionais de tentativa e erro para obter a solução do problema. Esses métodos, dos quais o mais empregado é o de Hardy-Cross, fazem tão somente o balanceamento da rede, deixando a cargo da experiência do projetista a busca de um dimensionamento mais econômico. Neste trabalho será apresentado um método que utiliza técnicas de programação não linear para o dimensionamento económico de redes malhadas. Esse método é composto de duas etapas. Na primeira, as vazões e os diâmetros são considerados como variáveis de decisão, e na segunda etapa, as variáveis de decisão são os comprimentos dos segmentos dos trechos, com diâmetros constantes, e suas correspondentes vazões. Essa metodologia foi aplicada a duas redes encontradas na literatura, em que o dimensionamento já havia sido feito por outros métodos de otimização. Os resultados mostram que o método da programação não linear apresenta uma eficácia maior na busca do custo mínimo de uma rede, quando comparado com outras metodologias de otimização de redes malhadas estudadas. / The design complexity of looped networks has forced to use traditional trial and error methods to attain a solution for the problem. Those methods, where the Hardy-Cross method is the most known among them, only carry out energy and mass balance of the network without dealing with the system's cost, that is, nor estimating neither improving the system's cost. In this work, a method for designing economical looped networks based on nonlinear programming is presented. To reduce the number of variables and, probabily, improve the performance of the solution procedure, this method is composed of two stages to reach an optimal solution. In a first stage, a nonlinear programming technique is applied to determine the flows and diameters of the pipes connecting two nodes of the network. In a second stage are chosen which are the upper and lower values of the results attained at the first stage for each pipe segment, and a nonlinear programming technique is applied once more to determine the length of each diameter for each pipe segment along with its flow. In both stages the objective function was related to the cost of the pipes and pumping requirements. This method has been applied to two examples of looped networks, which have been used in the literature to illustrate the application of other optimization methods developed by other authors. The optimal solutions attained from the method presented herein have shown to be better than the ones resulting from the application of any other method, which were taken into account for comparison in this work.

Page generated in 0.0406 seconds