• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 11
  • 10
  • 5
  • 2
  • 1
  • 1
  • Tagged with
  • 31
  • 31
  • 23
  • 11
  • 11
  • 9
  • 8
  • 8
  • 7
  • 7
  • 7
  • 6
  • 6
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Kompozitinių medienos-betono sijų ir jungių kūrimas ir bandymai / Development and Testing of Composite Timber-Concrete Beams and Connectors

Gurkšnys, Kęstutis 06 March 2006 (has links)
Recently more and more buildings of light structures have been built in Lithuania as well as in other European and world countries. Nevertheless, timber products are not widely used for floors in this share of construction market. Traditional light timber frame floors are characterized by vibrations, acoustic transmission and low fire resistance. The above-mentioned problems can be rationally solved by using timber-concrete composite (hereinafter TCC) floors. In comparison with entirely timber floors such type of floors are characterised not only by increased strength and stiffness but also by increased fire resistance and better sound insulation. In comparison with reinforced concrete floors manufactured of non-regenerative sources TCC floors are lighter and more economic. These characteristics stimulate usage of TCC floors in newly built buildings. It should also be noted that usage of timber in building structures instead of concrete or steel could substantially decrease energy demand and emission of carbon dioxide during production. In this work author presents TCC structural solution when thin-webbed beams (I-joists) used for timber floor beams instead of solid or glued rectangular beams. Thin-webbed beams are without upper flange of structural timber. Embedding in concrete a part of web of oriented strand board (hereinafter OSB) connects the OSB web and the concrete slab. This concept allows to save structural materials and production costs. Nevertheless, not so many... [to full text]
12

Kompozitinių medienos-betono sijų ir jungių kūrimas ir bandymai / Development and Testing of Composite Timber-Concrete Beams and Connectors

Gurkšnys, Kęstutis 06 March 2006 (has links)
Recently more and more buildings of light structures have been built in Lithuania as well as in other European and world countries. Nevertheless, timber products are not widely used for floors in this share of construction market. Traditional light timber frame floors are characterized by vibrations, acoustic transmission and low fire resistance. The above-mentioned problems can be rationally solved by using timber-concrete composite (hereinafter TCC) floors. In comparison with entirely timber floors such type of floors are characterised not only by increased strength and stiffness but also by increased fire resistance and better sound insulation. In comparison with reinforced concrete floors manufactured of non-regenerative sources TCC floors are lighter and more economic. These characteristics stimulate usage of TCC floors in newly built buildings. It should also be noted that usage of timber in building structures instead of concrete or steel could substantially decrease energy demand and emission of carbon dioxide during production. In this work author presents TCC structural solution when thin-webbed beams (I-joists) used for timber floor beams instead of solid or glued rectangular beams. Thin-webbed beams are without upper flange of structural timber. Embedding in concrete a part of web of oriented strand board (hereinafter OSB) connects the OSB web and the concrete slab. This concept allows to save structural materials and production costs. Nevertheless, not so many... [to full text]
13

Avaliação da influência de materiais obturadores endodônticos sobre a resistência de união adesiva de pinos de fibra de vidro cimentados / Evaluation of the influence of filling endodontic materials on the bond strength of fiberglass posts cemented

Vasconcelos, Rafaela Andrade de [UNESP] 18 March 2016 (has links)
Submitted by RAFAELA ANDRADE DE VASCONCELOS null (rafaela-vasconcelos@hotmail.com) on 2016-04-27T21:04:50Z No. of bitstreams: 1 vasconcelos_ra_dr_sjc.pdf: 1223725 bytes, checksum: f212f1adab3c030b4b7089bfeacaf463 (MD5) / Approved for entry into archive by Juliano Benedito Ferreira (julianoferreira@reitoria.unesp.br) on 2016-04-27T21:10:57Z (GMT) No. of bitstreams: 1 vasconcelos_ra_dr_sjc.pdf: 1223725 bytes, checksum: f212f1adab3c030b4b7089bfeacaf463 (MD5) / Made available in DSpace on 2016-04-27T21:10:57Z (GMT). No. of bitstreams: 1 vasconcelos_ra_dr_sjc.pdf: 1223725 bytes, checksum: f212f1adab3c030b4b7089bfeacaf463 (MD5) Previous issue date: 2016-03-18 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O propósito deste estudo foi avaliar, in vitro, a influência de remanescente de materiais obturadores endodônticos, após desobturação e preparo para pino, sobre a resistência de união adesiva de pinos de fibra de vidro cimentados. Foram utilizados 60 dentes humanos unirradiculados sem coroa. As raízes foram preparadas pela técnica coroa-ápice com sistema Reciproc. Para obturação, as raízes foram divididas em grupos (n = 10) de acordo com o cimento endodôntico utilizado: SO= sem obturação; GP=guta percha sem cimento; AHP= guta-percha + AHPlus; SLP= guta-percha + Sealapex; IRT= guta-percha + iRoot SP; e ERZ= guta-percha + EndoRez. As raízes foram obturadas pela técnica do cone único. A cimentação dos pinos de fibra de vidro Rebilda n.12 foi realizada com sistema adesivo futurabond DC e cimento Rebilda DC em 10 mm do comprimento da raiz. Após esse período, as raízes foram seccionadas obtendo-se discos de 2 mm de espessura em cada terço da raiz (3 discos por raiz) que foram submetidos ao teste de push out, análise por meio de uma lupa estereoscópica (40x) para identificação através de scores da presença de remanescente de material obturador na luz do canal e avaliação por espectroscopia de energia dispersiva (EDS) para identificação de remanescente de componentes químicos do cimento endodôntico presentes nos túbulos dentinários. Os dados obtidos foram analisados estatisticamente pelos testes de Kruskal Wallis, Qui Quadrado e teste de Anova e Tukey, todos com nível de significância de 5%. Não houve diferença estatística para a resistência adesiva entre os cimentos na região cervical (p = 0,49), media (p = 0,28) e apical (p = 0,09). Os grupos SLP e ERZ apresentaram menos remanescente de material obturador nas regiões cervical (p = 0,045) e apical (p = 0,006). Significantes diferenças de remanescentes de componentes químicos foram observadas na região apical dos grupos AHP, IRT e SLP. Conclui-se que os materiais endodônticos não influenciaram na resistência de união adesiva de pinos de fibra de vidro. / The purpose of this study was to evaluate the influence of remnants endodontic filling material in root canal on the bond strength of fiberglass posts cemented. Sixty single-rooted human teeth were used.Crowns were removed. The roots were prepared by crown-down technique with Reciproc system. For fillings, the roots were divided (n = 10) according to the sealer used: SO- without fillings; GP-gutta-percha without sealer; AHP- gutta-percha + AHPlus; SLP- gutta-percha + Sealapex; IRT-gutta-percha + iRoot SP; ERZ-and gutta-percha + EndoRez. Single cone obturation technique was used. After root canal fillings, the teeth were kept in an oven 37 0C for 7 days. Cementing fiberglass posts Rebilda n.12 was performed with fiber adhesive system Futurabond DC and cement Rebilda DC in 10 mm of root length, getting stored in an oven at 37 0C for 48 h. After this period, roots were sectioned obtaining 1 disc of 2 mm thickness in each third of the root (3 discs per root), this discs were underwent to push out test, analyzed by means of a stereomicroscope (40x) to identify the presence of remnants of filling material in the lumen of the canal, and then evaluated by energy dispersive spectroscopy (EDS) for identification of chemical components remnants sealer present in the dentinal tubules. Datas were analyzed with Kruskal-Wallis test, Chi square test, and also Anova and Tukey test, 5% of significance. There were no significant differences in push-out bond strengths among the different groups in the coronal (p = 0.49), middle (p = 0.28) or apical third (p = 0.09). Sealeapex and EndoRez groups showed significantly less remnants of filling material at coronal (p = 0.045) and apical levels (p = 0.006).Significant differences of chemical components remnants were found in AHP, IRT and SLP groups on apical third. It is concluded that residual endodontic filling material does not influence on the bond strength of fiberglass.
14

Avaliação da resistência da união de cimentos obturadores resinosos à dentina radicular, por meio do teste push-out acoplado ao microtomógrafo / Evaluation of bond strength of resin-based sealers to radicular dentin by push-out test coupled to a microtomography

Manoel Brito Júnior 05 December 2014 (has links)
O objetivo deste estudo foi avaliar a resistência de união à dentina da obturação de canais radiculares com cimentos à base de resina epóxica e de metacrilato, por meio do dispositivo material testing stage (MTS) acoplado ao microtomógrafo (&mu;CT), bem como avaliar qualitativamente a ruptura da massa obturadora por meio de imagens de &mu;CT. Além disso, foram utilizados o método de elementos finitos 3D e microscopia confocal de varredura a laser (MCVL) para verificar, respectivamente, a distribuição de tensões e presença de gaps na interface de união. Raízes de caninos superiores com 17 mm de comprimento foram submetidas ao preparo biomecânico com instrumentos rotatórios de níquel titânio, sob irrigação constante com NaOCl 1% e irrigação final com EDTA 17%. Os canais foram obturados pela técnica da condensação lateral com cones de guta percha e os cimentos: AH Plus, Epiphany SE ou RealSeal XT. As raízes foram armazenadas (100% de umidade, 37°C) por três vezes o tempo de endurecimento do cimento utilizado. Após este período, as raízes foram seccionadas para obtenção de dois slices (2 mm) de cada terço radicular. Um slices de cada terço foi submetido ao teste de push-out através de dispositivo mecânico MTS acoplado ao &mu;CT SkyScan 1174 (50kV, 80mA). Após o escaneamento inicial do slices, com resolução isotrópica de 13 &mu;m, filtro de 0.5 mm de Al e 360º de rotação, o teste mecânico foi iniciado até que ocorresse o deslocamento do material. Novo escaneamento foi realizado com os mesmos parâmetros iniciais, que determinou regiões de ruptura da massa obturadora em secções axiais. Os tipos de falhas foram avaliados por MCVL e classificadas em: adesivas, coesivas e mistas. Modelos 3D de elementos finitos foram gerados para os terços cervical, médio e apical, a partir de imagens de &mu;CT. No segundo slices de cada terço radicular, foi aferido o percentual de gaps do material obturador às paredes do canal radicular, por meio de MCVL e do programa OLS 4000. Os dados foram analisados por testes estatísticos paramétricos e não paramétricos (p<0,05). O cimento AH Plus [1,89 (1,01/2,39) MPa] apresentou maior resistência de união à dentina (p<0,001) quando comparado aos cimentos Epiphany SE [0,36 (0,29/0,44) MPa] e RealSeal XT [0,43 (0,32/0,54) MPa]. Para os cimentos AH Plus e RealSeal XT, os terços cervical e médio apresentaram maior resistência de união à dentina que o terço apical (p<0,001). As rupturas ocorreram nas margens da massa obturadora para o cimento AH Plus, enquanto os cimentos Epiphany SE e RealSeal XT tiveram este tipo de ruptura, bem como na própria massa obturadora. No cimento AH Plus, a interface de união mostrou maior concentração de tensões, que foram distribuídas principalmente na massa obturadora para os cimentos Epiphany SE e RealSeal XT. Houve predominância de falhas adesivas e mistas em todos os cimentos. Em relação ao percentual de gaps, o cimento AH Plus apresentou as menores médias (11,14% ± 4,03), com diferença estatisticamente significante (p<0,05) dos cimentos Epiphany SE (55,39% ± 13,46) e RealSeal XT (62,50% ± 6,72). O cimento à base de resina epóxica (AH Plus) apresentou a maior resistência de união à dentina e teve comportamento diferente em relação aos outros cimentos, quanto à ruptura da massa obturadora e distribuição de tensão interfacial. Além disso, o cimento AH Plus apresentou o menor percentual de gaps entre o material obturador e as paredes do canal radicular / The aim of this study was to evaluate the bond strength of epoxy resin- and methacrylate-based sealers to root dentin, using the material testing stage (MTS) coupled to a micro-computed tomography (&mu;CT) device and to qualitatively assess the root-filling mass rupture by &mu;CT images. Additional analyses were conducted using the 3D element finite method and confocal laser scanning microscopy (CLSM) to verify, respectively, the stress distribution and percentage of gaps on dentin filling material interfaces. Maxillary canine roots measuring 17 mm were subjected to biomechanical preparation with nickel-titanium rotary instruments under constant irrigation with 1% NaOCl and final irrigation with 17% EDTA. Canals were filled by the lateral condensation technique with gutta-percha cones and the following sealers: AH Plus, Epiphany SE or RealSeal XT. The roots were stored (100% humidity, 37 °C) for a period three times longer than the setting time required for each sealer and then sectioned transversally to obtain two 2-mm-thick slices from each root third. One slice of each third was subjected to the push-out test using the MTS coupled to the SkyScan 1174 &mu;CT (50 kV, 80 mA) with 13 &mu;m isotropic resolution, 0.5 mm Al filter and 360° rotation. After the initial scanning of the slice, the mechanical test was performed until material dislodgement occurred. A new scanning was performed using the same initial parameters. The axial sections obtained were used for qualitative evaluation of the root-filling mass rupture. Failure modes were assessed by CLSM and classified as adhesive, cohesive or mixed. 3D &mu;CT based finite element models were generated from cervical, middle and apical root thirds to simulate the push-out test. The second slice of each root third was used to assess the percentage of gaps between the filling material and the root canal walls, using CLSM with the aid of the OLS 4000 software. The data were analyzed by parametric and non-parametric tests (p<0.05). AH Plus presented higher bond strength [1.89 (1.01/2.39) MPa] to dentin (p<0.001) than Epiphany SE [0.36 (0.29/0.44) MPa] and RealSeal XT [0.43 (0.32/0.54) MPa]. For AH Plus and RealSeal XT sealers, the cervical and middle thirds showed higher bond strength to dentin than the apical third (p <0.001). The ruptures occurred in the margins of the root filling mass for AH Plus, while Epiphany SE and RealSeal XT had this type of rupture as well as in the root filling mass itself. AH Plus showed stress concentration on bond interface, while in Epiphany SE and RealSeal XT the stress was mainly distributed on the root-filling mass. Adhesive and mixed failures were the predominant fracture modes in all sealers. Regarding the percentage of gaps between the filling material and the root canal walls, AH Plus presented the lowest means (11.14%±4.03), differing significantly (p<0.05) from Epiphany SE (55.39%±13.46) and RealSeal XT (62.50%±6.72) sealers. The epoxy resin-based sealer (AH Plus) presented the highest bond strength to dentin, which had different behavior from other sealers regarding root-filling mass rupture and interfacial stress distribution. Moreover, AH Plus resulted in the lowest percentage of gaps between the material and the root canal walls
15

Efeito da técnica úmida simplificada de adesão com etanol na cimentação intraradicular de pinos de fibra / Push-out bond strength and SEM evaluation of new bonding approach into the root canal

Carlos Augusto Ramos de Carvalho 28 June 2011 (has links)
Este estudo avaliou a resistência ao deslocamento vertical push-out de pinos de fibra de vidro cimentados à dentina intra-radicular utilizando uma resina fluida padrão como agente cimentante em combinação com um adesivo dentinário experimental e um adesivo disponível comercialmente. 20 pré-molares unirradiculares humanos foram previamente extraídos e tratados endodonticamente. Os espécimes foram divididos em quatro estratégias de união a dentina: Grupo 1 com adesivo experimental com etanol na proporção em volume 1:1 (resina/etanol) e Grupo 2 com adesivo experimental com etanol na proporção em volume 1:2(resina/etanol); adesivos experimentais aplicados de acordo com a técnica úmida de adesão simplificada com etanol, Grupo 3: One-Step Plus aplicado de acordo com a técnica úmida de adesão simplificada com etanol; Grupo 4: One-Step Plus aplicado seguindo as instruções do fabricante. Os espécimes foram seccionados em fatias de 1 mm de espessura e apos o teste push-out foi realizado. Espécimes representativos foram selecionados para exame ultra-estrutural. Não houve diferença estatística na resistência ao deslocamento push-out entre as estratégias testadas de adesão (p> 0,05). O padrão predominante de fratura foi entre os pinos de fibra e o agente cimentante. A partir deste estudo devemos considerar como promissora a técnica com etanol utilizada na cimentação de pinos no canal radicular devido aos possíveis benefícios das resinas altamente hidrófobas. Mais estudos são necessários para validar o uso da técnica úmida de adesão simplificada com etanol quando cimentados pinos de fibra. / This study evaluated the push-out bond strength of glass fiber posts adhesively bonded to intraradicular dentin using a standard unfilled resin as luting agent in combination with an experimental and a commercially available adhesive. Twenty extracted single-rooted human teeth were endodontically treated. Specimens were assigned to 4 dentin bonding strategies: Group 1 (co-monomers to ethanol on ratio 1:1) and Group 2 (co-monomers to ethanol on ratio 1:2): Experimental adhesives applied in accordance with the simplified ethanol-wet bonding technique; Group 3: One-Step Plus (OSP) applied in accordance with the simplified ethanol-wet bonding technique; Group 4: OSP applied following manufacturers instructions. Bonded specimens were sectioned in 1-mm-thick slices and the push-out test was performed. Representative specimens were selected for ultrastructural examination. No statistical differences in push-out bond strength were found among the tested bonding strategies (p>0.05). The major failure pattern was between the post and the luting cement. From this study the ethanol technique should be considered as a promising approach in the luting of fiber posts into the root canal due to the possible benefits of highly hydrophobic resins. Further studies are needed to validate the use of the ethanol-wet bonding technique when luting a fiber post.
16

Study on flexural behavior of steel-concrete composite deck with DFT connectors / DFT形鋼ジベルを用いた鋼-コンクリート合成床版の曲げ挙動に関する研究

Hu, Yiming 24 July 2023 (has links)
京都大学 / 新制・課程博士 / 博士(工学) / 甲第24847号 / 工博第5164号 / 新制||工||1986(附属図書館) / 京都大学大学院工学研究科社会基盤工学専攻 / (主査)教授 杉浦, 邦征, 教授 高橋, 良和, 教授 山本, 貴士, 教授 北根, 安雄 / 学位規則第4条第1項該当 / Doctor of Philosophy (Engineering) / Kyoto University / DGAM
17

Proposição de um teste de aderência apropriado para controle tecnológico da resistência à compressão do concreto / Proposal of an appropriate bond test for the technological control of the compressive strength of the concrete

Silva, Bruno do Vale January 2014 (has links)
Esta pesquisa propõe-se estudar a viabilidade de um ensaio de aderência aço-concreto apropriado (Appropriate Bond Test - ABT) para estimativa da resistência à compressão axial do concreto, objetivando empregá-lo como complemento ao controle de qualidade do concreto armado em campo. Originalmente os autores Lorrain e Barbosa (2008) apresentaram a utilização de um ensaio de aderência apropriado, denominado APULOT, para estimar a resistência à compressão do concreto, aumentando as possibilidades de controle tecnológico do concreto armado em canteiros de obras. Os mesmos propõem uma adaptação do método pull-out test (POT) tradicional, normalizado pela RILEM CEB/FIP RC6:1983, por ser este um ensaio de baixa complexidade e de custo reduzido. Para viabilizar o uso de um ensaio de aderência apropriado como ensaio de controle tecnológico do concreto em canteiro de obras é necessário definir um padrão para o mesmo e adaptá-lo da prática experimental do laboratório para o campo. O presente trabalho buscou avaliar os seguintes parâmetros: (1) Tipo de carregamento do ensaio (pull-out e push-in); (2) Influência do tipo de configuração geométrica das barras de aço; (3) Análises da preparação, moldagem, cura e estocagem dos corpos de prova do ABT; (4) Análises quanto à execução do ABT referentes à idade de ruptura, taxa de carregamento e tipo de ruptura; (5) Implementação do ABT em canteiro de obras, avaliando a sua potencialidade de efetuar estimativas da resistência à compressão a partir dos dados da tensão de aderência. Para tanto, foram ensaiadas 26 composições de concreto de classes distintas, com idades entre 3 e 28 dias. Foram, ainda, testadas 8 configurações distintas de barras de aço com diâmetros nominais de 8 e 12,5 mm. Os resultados obtidos mostram que, sob condições padronizadas de ensaio e adotando os coeficientes adequados, a correlação entre a tensão máxima de aderência e a resistência à compressão do concreto é satisfatória, fortalecendo o propósito de consolidar este ensaio como uma alternativa complementar para controle de qualidade do concreto armado. / This research proposes a study on the feasibility of bond test steel-concrete appropriate (Appropriate Bond Test - ABT) to estimate the compressive strength of concrete, aiming to use them as a supplement in the quality control of concrete in situ. Originally the authors Lorrain and Barbosa (2008) proposed the use of a modified bond test, called APULOT to estimate the compressive strength of the concrete, increasing the possibilities for technological control of reinforced concrete on construction sites. They propose an adaptation of the traditional method pull-out test (POT), normalized by the CEB / FIP RC6: 1983, because it is a test of low complexity and low cost. To enable the use of the test as a test technological control of concrete in construction site is necessary to define a standard for yourself and adapt it practice experimental laboratory to the field. This study evaluated the following parameters: (1) Type of load test (pull-out and push-in); (2) Influence of the type of geometric configuration of steel bar; (3) Analyses of preparation, molding, curing and storage of specimens of ABT; (4) Review of the implementation of ABT on age rupture, loading rate and type of fracture; (5) Implementation of ABT in construction site, evaluating its potential to make estimates of compressive strength from the data of bond stress. Therefore, 26 different compositions of concrete classes, aged between 3 and 28 days, were tested. Were also tested 8 different configurations of steel bars with nominal diameters of 8 and 12.5 mm. The results indicate that, under standard testing and adopting the appropriate coefficients conditions, the correlation between the maximum bond stress and the compressive strength of concrete is satisfactory, strengthening the purpose of consolidating this test as a complementary alternative to quality control reinforced concrete.
18

Proposição de um teste de aderência apropriado para controle tecnológico da resistência à compressão do concreto / Proposal of an appropriate bond test for the technological control of the compressive strength of the concrete

Silva, Bruno do Vale January 2014 (has links)
Esta pesquisa propõe-se estudar a viabilidade de um ensaio de aderência aço-concreto apropriado (Appropriate Bond Test - ABT) para estimativa da resistência à compressão axial do concreto, objetivando empregá-lo como complemento ao controle de qualidade do concreto armado em campo. Originalmente os autores Lorrain e Barbosa (2008) apresentaram a utilização de um ensaio de aderência apropriado, denominado APULOT, para estimar a resistência à compressão do concreto, aumentando as possibilidades de controle tecnológico do concreto armado em canteiros de obras. Os mesmos propõem uma adaptação do método pull-out test (POT) tradicional, normalizado pela RILEM CEB/FIP RC6:1983, por ser este um ensaio de baixa complexidade e de custo reduzido. Para viabilizar o uso de um ensaio de aderência apropriado como ensaio de controle tecnológico do concreto em canteiro de obras é necessário definir um padrão para o mesmo e adaptá-lo da prática experimental do laboratório para o campo. O presente trabalho buscou avaliar os seguintes parâmetros: (1) Tipo de carregamento do ensaio (pull-out e push-in); (2) Influência do tipo de configuração geométrica das barras de aço; (3) Análises da preparação, moldagem, cura e estocagem dos corpos de prova do ABT; (4) Análises quanto à execução do ABT referentes à idade de ruptura, taxa de carregamento e tipo de ruptura; (5) Implementação do ABT em canteiro de obras, avaliando a sua potencialidade de efetuar estimativas da resistência à compressão a partir dos dados da tensão de aderência. Para tanto, foram ensaiadas 26 composições de concreto de classes distintas, com idades entre 3 e 28 dias. Foram, ainda, testadas 8 configurações distintas de barras de aço com diâmetros nominais de 8 e 12,5 mm. Os resultados obtidos mostram que, sob condições padronizadas de ensaio e adotando os coeficientes adequados, a correlação entre a tensão máxima de aderência e a resistência à compressão do concreto é satisfatória, fortalecendo o propósito de consolidar este ensaio como uma alternativa complementar para controle de qualidade do concreto armado. / This research proposes a study on the feasibility of bond test steel-concrete appropriate (Appropriate Bond Test - ABT) to estimate the compressive strength of concrete, aiming to use them as a supplement in the quality control of concrete in situ. Originally the authors Lorrain and Barbosa (2008) proposed the use of a modified bond test, called APULOT to estimate the compressive strength of the concrete, increasing the possibilities for technological control of reinforced concrete on construction sites. They propose an adaptation of the traditional method pull-out test (POT), normalized by the CEB / FIP RC6: 1983, because it is a test of low complexity and low cost. To enable the use of the test as a test technological control of concrete in construction site is necessary to define a standard for yourself and adapt it practice experimental laboratory to the field. This study evaluated the following parameters: (1) Type of load test (pull-out and push-in); (2) Influence of the type of geometric configuration of steel bar; (3) Analyses of preparation, molding, curing and storage of specimens of ABT; (4) Review of the implementation of ABT on age rupture, loading rate and type of fracture; (5) Implementation of ABT in construction site, evaluating its potential to make estimates of compressive strength from the data of bond stress. Therefore, 26 different compositions of concrete classes, aged between 3 and 28 days, were tested. Were also tested 8 different configurations of steel bars with nominal diameters of 8 and 12.5 mm. The results indicate that, under standard testing and adopting the appropriate coefficients conditions, the correlation between the maximum bond stress and the compressive strength of concrete is satisfactory, strengthening the purpose of consolidating this test as a complementary alternative to quality control reinforced concrete.
19

Proposição de um teste de aderência apropriado para controle tecnológico da resistência à compressão do concreto / Proposal of an appropriate bond test for the technological control of the compressive strength of the concrete

Silva, Bruno do Vale January 2014 (has links)
Esta pesquisa propõe-se estudar a viabilidade de um ensaio de aderência aço-concreto apropriado (Appropriate Bond Test - ABT) para estimativa da resistência à compressão axial do concreto, objetivando empregá-lo como complemento ao controle de qualidade do concreto armado em campo. Originalmente os autores Lorrain e Barbosa (2008) apresentaram a utilização de um ensaio de aderência apropriado, denominado APULOT, para estimar a resistência à compressão do concreto, aumentando as possibilidades de controle tecnológico do concreto armado em canteiros de obras. Os mesmos propõem uma adaptação do método pull-out test (POT) tradicional, normalizado pela RILEM CEB/FIP RC6:1983, por ser este um ensaio de baixa complexidade e de custo reduzido. Para viabilizar o uso de um ensaio de aderência apropriado como ensaio de controle tecnológico do concreto em canteiro de obras é necessário definir um padrão para o mesmo e adaptá-lo da prática experimental do laboratório para o campo. O presente trabalho buscou avaliar os seguintes parâmetros: (1) Tipo de carregamento do ensaio (pull-out e push-in); (2) Influência do tipo de configuração geométrica das barras de aço; (3) Análises da preparação, moldagem, cura e estocagem dos corpos de prova do ABT; (4) Análises quanto à execução do ABT referentes à idade de ruptura, taxa de carregamento e tipo de ruptura; (5) Implementação do ABT em canteiro de obras, avaliando a sua potencialidade de efetuar estimativas da resistência à compressão a partir dos dados da tensão de aderência. Para tanto, foram ensaiadas 26 composições de concreto de classes distintas, com idades entre 3 e 28 dias. Foram, ainda, testadas 8 configurações distintas de barras de aço com diâmetros nominais de 8 e 12,5 mm. Os resultados obtidos mostram que, sob condições padronizadas de ensaio e adotando os coeficientes adequados, a correlação entre a tensão máxima de aderência e a resistência à compressão do concreto é satisfatória, fortalecendo o propósito de consolidar este ensaio como uma alternativa complementar para controle de qualidade do concreto armado. / This research proposes a study on the feasibility of bond test steel-concrete appropriate (Appropriate Bond Test - ABT) to estimate the compressive strength of concrete, aiming to use them as a supplement in the quality control of concrete in situ. Originally the authors Lorrain and Barbosa (2008) proposed the use of a modified bond test, called APULOT to estimate the compressive strength of the concrete, increasing the possibilities for technological control of reinforced concrete on construction sites. They propose an adaptation of the traditional method pull-out test (POT), normalized by the CEB / FIP RC6: 1983, because it is a test of low complexity and low cost. To enable the use of the test as a test technological control of concrete in construction site is necessary to define a standard for yourself and adapt it practice experimental laboratory to the field. This study evaluated the following parameters: (1) Type of load test (pull-out and push-in); (2) Influence of the type of geometric configuration of steel bar; (3) Analyses of preparation, molding, curing and storage of specimens of ABT; (4) Review of the implementation of ABT on age rupture, loading rate and type of fracture; (5) Implementation of ABT in construction site, evaluating its potential to make estimates of compressive strength from the data of bond stress. Therefore, 26 different compositions of concrete classes, aged between 3 and 28 days, were tested. Were also tested 8 different configurations of steel bars with nominal diameters of 8 and 12.5 mm. The results indicate that, under standard testing and adopting the appropriate coefficients conditions, the correlation between the maximum bond stress and the compressive strength of concrete is satisfactory, strengthening the purpose of consolidating this test as a complementary alternative to quality control reinforced concrete.
20

Resistência da união ao teste de push-out de cimentos resinosos auto-adesivos em dentina radicular / Push-out bond strength of self-adhesive resin cements on root dentin

Gonçalves, Mariella Agostinho 30 March 2012 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-05-18T14:35:18Z No. of bitstreams: 1 mariellaagostinhogoncalves.pdf: 2206097 bytes, checksum: 736acf1d28715f5b3a331257446b5b23 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-07-01T18:48:04Z (GMT) No. of bitstreams: 1 mariellaagostinhogoncalves.pdf: 2206097 bytes, checksum: 736acf1d28715f5b3a331257446b5b23 (MD5) / Made available in DSpace on 2016-07-01T18:48:04Z (GMT). No. of bitstreams: 1 mariellaagostinhogoncalves.pdf: 2206097 bytes, checksum: 736acf1d28715f5b3a331257446b5b23 (MD5) Previous issue date: 2012-03-30 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Neste estudo, avaliou-se a resistência da união ao push-out de dois cimentos resinosos auto-adesivos e de um cimento resinoso convencional em dentina radicular. Em 60 dentes terceiros molares humanos, tratados endodonticamente, um pino de fibra de vidro foi cimentado com um dos três cimentos resinosos. Cada raiz foi seccionada em sentido transversal para a obtenção de três fatias (dentina-pino) de 1 mm de espessura. As fatias, correspondentes aos terços cervical, médio e apical do canal radicular, foram armazenadas em água deionizada a 37 ºC, durante 24 horas ou 30 dias. Após o teste de push-out, os valores de resistência da união foram submetidos aos testes estatísticos ANOVA three way e Tuckey (p = 0,05) e os tipos de fratura foram avaliados através de microscopia eletrônica de varredura. A resistência da união do cimento resinoso auto-adesivo RelyX U100 foi superior à do cimento convencional RelyX ARC, após os dois períodos de armazenamento (p < 0,05). No terço cervical, os valores de resistência da união do cimento resinoso convencional RelyX ARC foram maiores que nos terços médio e apical (p < 0,05) na análise de 24 horas. Após 30 dias de armazenamento, os valores nos três terços radiculares não diferiram entre si. Os valores de resistência da união do cimento resinoso RelyX U100, nas três regiões do canal radicular, não diferiram entre si (p > 0,05), em ambos os momentos de avaliação. Após 24 horas, BisCem apresentou maior resistência da união no terço apical, seguido pelo terço cervical. Após 30 dias, os valores de resistência da união nos três terços radiculares não diferiram entre si (p > 0,05). RelyX U100 não sofreu alteração nos valores de resistência da união após 30 dias de envelhecimento (p > 0,05). BisCem não apresentou diferenças nos valores obtidos após 24 horas e 30 dias de envelhecimento nos terços cervical e médio (p > 0,05). Para RelyX ARC, o tempo de 30 dias reduziu os valores de resistência da união nos três terços radiculares. RelyX U100 e BisCem apresentaram maior número de falhas coesivas da zona de interação. Para RelyX ARC, observou-se maior número de falhas coesivas da camada híbrida. Concluiu-se que o cimento resinoso auto-adesivo RelyX U100 apresentou maior resistência da união que o cimento resinoso convencional RelyX ARC, nos três terços radiculares, nos dois momentos de avaliação. BisCem demonstrou resistência da união comparável a do cimento RelyX U100. O tempo de armazenamento por 30 dias provocou alteração na resistência da união dos cimentos resinosos RelyX ARC e BisCem. / This study evaluated the push-out bond strength of two self-adhesive resin cements and a conventional etch-and-rinse resin cement on root dentin. Sixty human third molars were endodontically treated and a glass fiber post was cemented with one of three resin cements. Each root was cut transversely to obtain three slices (dentin-post) of 1 mm thick. The slices of the cervical, middle and apical root canal were stored in deionized water at 37 °C for 24 hours or 30 days. After storage, the push-out test was performed. The values of bond strength were evaluated by ANOVA three way and Tuckey’ test (p = 0,05) and the types of fracture were evaluated by scanning electron microscopy. The bond strength of the self-adhesive resin cement RelyX U100 was superior to the RelyX ARC etch-and-rinse cement, after the two storage periods (p > 0.05). The analysis of 24 hours showed that at the cervical third, the values of bond strength of RelyX ARC were higher than that of the middle and apical thirds (p < 0.05). After 30 days of storage, the values at the three root thirds did not differ. The values of RelyX U100, on the three regions of the root canal did not differ, in both evaluations (p > 0.05). After 24 hours, BisCem showed higher bond strength at the apical third, followed by cervical. After 30 days, the values of bond strength at the three root thirds did not differ (p > 0.05). RelyX U100 did not exhibit changes in bond strength values after 30 days of storage (p > 0.05). BisCem showed no differences in the values obtained after 24 hours and 30 days of aging at the cervical and middle thirds (p > 0.05). The storage time of 30 days reduced the values of bond strength at the three root thirds of RelyX ARC. RelyX U100 e BisCem had the highest number of cohesive failures of the zone of interaction. RelyX ARC presented a higher number of cohesive failures of the hybrid layer were observed. It was concluded that the RelyX U100 self-adhesive resin cement showed higher bond strength than the conventional resin cement RelyX ARC, on the three root thirds, in both periods. BisCem showed bond strength comparable to RelyX U100. The storage time for 30 days caused changes on the bond strength of the RelyX ARC and BisCem resin cements.

Page generated in 0.0602 seconds