• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 851
  • 162
  • 105
  • 72
  • 8
  • 8
  • 7
  • 7
  • 7
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 1202
  • 1202
  • 256
  • 249
  • 234
  • 180
  • 170
  • 170
  • 168
  • 151
  • 132
  • 112
  • 93
  • 93
  • 77
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Biosorption of heavy metals from aqueous solutions using keratin biomaterials

Zhang, Helan 22 July 2014 (has links)
La biosorció és una tècnica eficaç per a l'eliminació de metalls pesants de les aigües residuals resultants de l’activitat humana, principalment de les activitats industrials actuals. Els biomaterials provinents de residus es consideren alternatives ideals com a nous biosorbentes donada la baixa relació del seu cost amb la seva eficàcia i alta capacitat d'adsorció per a metalls pesants. Una àmplia gamma de biomaterials de baix cost provinents de residus, alguns dels quals provenen de processos d'operacions industrials a gran escala, s'han emprat amb èxit com a biosorbents aplicats a l'eliminació de metalls pesants, principalment d’aigües residuals. Com a tipus abundant de recurs biològic, els biomaterials amb base de queratina s'investiguen actualment per a aquest propòsit. Aquests biomaterials mostren una alta capacitat de biosorció de metalls pesants a causa del seu alt contingut en grups funcionals carboxil, hidroxil, amino, així com grups que contenen sofre. Aquesta tesi té a veure amb l'ús de biomaterials de queratina, especialment cabell humà, pèl de gos, plomes de pollastre i llana desgreixada, com a materials biosorbents emprats per a l'eliminació de metalls pesants de solucions aquoses. En primer lloc, es va investigar l'eliminació de metalls pesants de solucions aquoses emprant diferents tipus de cabell humà. Es va trobar que el pèl tenyit mostra les millors capacitats de biosorció per a tots els ions de metalls pesants triats. Sobre la base d'aquest resultat preliminar, es van seleccionar dues mostres de cabell humà, incloent cabell natural (H1) i cabell tenyit (H2) per mirar de comprovar-ne la seva eficàcia com a biosorbents de metalls pesants. De manera que es realitza una comparació sistemàtica del procés de biosorció per a l'eliminació d’ions com Cr (III), Ni (II), Co (II), Mn (II), Cu (II), Zn (II), Cd (II) i Pb (II) sota diferents condicions. El cabell H2 (cabell tenyit) va mostrar una millor capacitat de biosorció que el cabell H1 (cabell natural). Aquest comportament, es podria atribuir a la major àrea superficial del primer, així com a la presència de més grups sulfonat (arrel del procés de tinció), fet que és confirmat per l'anàlisi SEM i FT-IR, respectivament. Les capacitats de biosorció dels metalls pesants segueix l'ordre següent: Cu(II) > Pb(II) > Cr(III) > Zn(II) > Cd(II) > Ni(II) > Co(II) > Mn(II) per al cabell H2, i Cu(II) > Cr(III) > Pb(II) per H1, de manera que la biosorció de la resta dels metalls pesants per H1 no va ser significativa. El model de cinètica de pseudo-segon ordre és el que millor s’ajusta i prediu el comportament cinètic de biosorció dels sistemes, per a tot el temps de contacte aplicat, sent la reacció química de sorció l'etapa que controla la velocitat del procés. La capacitat de biosorció màxima de Pb(II) per H1 i H2, segons el model de l’isoterma de Langmuir és de 1,7×10-5 i 23,2×10-5 mol/g a 295 K, respectivament. L'efecte dels grups sulfonat en la superfície del cabell (H2) pot millorar la seva capacitat de biosorció, així com l'eficiència de la següent elució amb EDTA. Les mostres de cabell humà regenerades amb EDTA mostren una bona capacitat de biosorció quan es reutilitzen. Així, el cabell humà es considera un potencial biosorbent per a l'eliminació de metalls pesants de mostres aquoses. Basant-nos en els resultats anteriors, s’arriba a la conclusió que el cabell H2 (cabell tenyit) mostra la millor capacitat de biosorció, de manera que es pot pensar en mirar de modificar químicament el cabell humà, de forma adequada, per tal de millorar la seva capacitat de biosorció original. Així, el cabell humà natiu va ser tractat per un mètode d'oxidació adient, i es va avaluar i comparar el seu rendiment de biosorció respecte el cabell natiu. La composició química i la morfologia del cabell humà després del tractament d'oxidació es van comprovar per anàlisis de FT-IR i SEM, respectivament, així com després d’emprar el biomaterial tractat en el procés de biosorció de metalls pesants. El cabell humà tractat va mostrar una millor capacitat de biosorció dels metalls pesants respecte al cabell natiu, tal i com era d’esperar, a causa de la major àrea de superfície obtinguda després del tractament, i de la presència de més grups sulfonat en la superfície del biomaterial, els quals s’han format a través de la reacció d'oxidació. S’han investigat els paràmetres que afecten a la biosorció dels metalls pesants, com ara temps de contacte, el valor inicial de pH de la solució, la dosi de biosorbent i la concentració inicial dels metalls. D'acord als estudis amb els models cinètics i les isotermes, el pas limitant del procés de biosorció sembla ser la reacció química de sorció que és la causant de la formació d'enllaços químics entre els ions metàl·lics i els grups funcionals del cabell humà tractat, en la monocapa de la superfície del biomaterial. La màxima capacitat de biosorció del cabell humà tractat per Cr (III), Cu (II), Cd (II) i Pb (II) segons el model de la isoterma de Langmuir a 295 K és 9,47×10-5, 5,57×10-5, 3,77×10-5 i 3,61x10-5 mol/g, respectivament. L’energia de Gibbs estàndard de signe negatiu indica que el procés de biosorció de metalls pesants és termodinàmicament factible i de naturalesa espontània. Els grups sulfonat del cabell humà tractat (formats en el tractament d'oxidació), no només milloren la capacitat de biosorció, sinó que també ajuden a la desorció dels ions metàl·lics estudiats mitjançant l'ús de solucions d'EDTA. A més, l’elució amb EDTA és beneficiosa per a la reutilització del biomaterial. Per tant, el cabell humà tractat pel mètode d'oxidació exhibeix una capacitat de biosorció de metalls pesants satisfactòria, de manera que es pot utilitzar com a biosorbent eficaç per a l'eliminació d’aquests a partir de solucions aquoses. Es van utilitzar quatre biomaterials comuns de rebuig de base de queratina, incloent el cabell humà, el pèl de gos, les plomes de pollastre i la llana desgreixada com biosorbents per a l'eliminació de metalls pesants de solucions aquoses. El procés de biosorció es va dur a terme en diferents condicions. La capacitat total de biosorció dels quatre biosorbents generalment segueix el següent ordre: la llana desgreixada > les plomes de pollastre > el cabell humà > el pèl de gos. Aquest comportament és probablement a causa de l'oxidació parcial de la llana original arrel del procés de desgreix, i de l'àrea de superfície alta de les plomes de pollastre, fets que es van confirmar per FT-IR i SEM, respectivament. Els resultats dels estudis cinètics del procés de biosorció amb aquests materials de queratina indiquen que la sorció química és el mecanisme bàsic del procés. Les dades experimentals s’ajusten molt bé al model de la isoterma de Langmuir, i el procés de biosorció és termodinàmicament factible i de naturalesa espontània, tal i com ja s'ha indicat anteriorment en el cas del cabell humà. Aquests quatre biomaterials de queratina regenerats amb EDTA i rentats amb aigua destil·lada mostren una bona capacitat de biosorció, especialment pel cas de la ploma del pollastre (amb baix contingut de cistina) i per la llana desgreixada (que es tracta de fibra de queratina prèviament oxidada en el procés de desgreixat). Els quatre residus de biomaterials de queratina, sent materials barats i fàcilment disponibles, podrien ser una alternativa adient als adsorbents més costosos utilitzats avui en dia per a l'eliminació de metalls pesants en els processos de tractament d'aigües residuals. Sobre la base d'aquests resultats, es pot afirmar que els biomaterials de queratina assajats es poden utilitzar com a potencials biosorbents per a l'eliminació de metalls pesants, i que el cabell humà tractat amb un procediment d'oxidació pot millorar la seva capacitat de biosorció. Per tant, els altres biomaterials de queratina, incloent el pèl de gos, les plomes de pollastre i la llana desgreixada es van tractar també utilitzant el mateix mètode de modificació química. El pèl de gos tractat mostra una millor capacitat de biosorció que el pèl de gos natiu, de manera similar al cas del cabell humà. No obstant, les capacitats de biosorció de les plomes de pollastre i de la llana desgreixada no milloren després del tractament d’oxidació, probablement degut a la condició de material modificat (especialment pel cas de la llana que ha estat desgreixada previament) i degut a la naturalesa i a les propietats dels biomaterials en si mateixos. Per tant, es continua amb la caracterització del pèl de gos tractat. Es preparen els corresponents experiments de biosorció del pèl de gos tractat per tal d’investigar els efectes de diversos paràmetres com ara els temps de contacte, el pH inicial de la solució aquosa i la dosi de biosorbent. També s’utilitzen models cinètics i d'isotermes per tal d’ajustar les dades experimentals obtingudes, tal que els resultats obtinguts indiquen que la sorció química és l'etapa limitant de velocitat del procés de biosorció, i la capacitat màxima de biosorció del pèl de gos tractat per Pb (II), segons el model de la isoterma de Langmuir és de 5,79×10-5 mol/g a 295 K. El pèl de gos tractat, també es pot reutilitzar després de l’elució amb EDTA i del rentat amb aigua destil·lada, com ja s’havia vist anteriorment. En conclusió, els biomaterials de residu de base de queratina poden ser utilitzats com a biosorbents de baix cost i alta eficàcia per a l’eliminació de metalls pesants de solucions aquoses. En general, el tractament d'oxidació pot millorar significativament la capacitat de biosorció d’aquests biomaterials. Cal considerar les millors condicions pel tractament d'oxidació per cada tipus de biomaterial de queratina, per tal d’assolir la millor modificació i eficàcia d’aquest. S'espera que aquests tipus de biomaterials de queratina puguin ser aplicats a gran escala per fer front a la descontaminació de metalls pesants de les aigües residuals industrials en un futur proper. / Biosorption is an effective technique for the removal of heavy metals from wastewaters resulting from human and industrial activities. Waste biomaterials are considered ideal alternatives as novel biosorbents due to the low relatively cost-effective ratio and the high efficient adsorption capacities for heavy metals. A vast array of low-cost waste biomaterials from large-scales industrial operations have been successfully employed as biosorbents for the removal of heavy metals from wastewaters. As a kind of abundant biological resources, keratin biomaterials are investigated currently for this purpose, which show high capacity of biosorption of heavy metals due to their high contents of carboxyl, hydroxyl, amino and sulfur-containing functional groups. This thesis is concerned with the use of keratin biomaterials, specifically human hair, dog hair, chicken feathers and degreased wool, as biosorbents for the removal of heavy metals from aqueous solutions. First of all, the removal of heavy metals from aqueous solutions by different kinds of human hair was investigated. It was found that the bleached and dyed hair showed the best biosorption capacities for all checked heavy metal ions. Based on these preliminary results, two human hair samples including native hair (H1) and bleached-dyed hair (H2) were selected to do further study. A systematic comparison of biosorption performance for removing Cr(III), Ni(II), Co(II), Mn(II), Cu(II), Zn(II), Cd(II) and Pb(II) ions from aqueous solution under different conditions, was provided. The H2 (bleached-dyed hair) showed better biosorption capacity than H1 (in native). It could be attributed to the higher surface area and more number of sulfonate groups, which is confirmed by the SEM and FT-IR analysis, respectively. The biosorption capacities of heavy metals followed the order Cu(II) > Pb(II) > Cr(III) > Zn(II) > Cd(II) > Ni(II) > Co(II) > Mn(II) for H2, and Cu(II) > Cr(III) > Pb(II) for H1, and the biosorption of the rest of the heavy metals for H1 was not significant. The pseudo-second order kinetic model is more likely to predict kinetic behavior of the metal biosorption process for whole contact time range, with the chemical sorption being the rate-controlling step. The maximum biosorption capacity of H1 and H2 for Pb(II) by Langmuir isotherm model were 1.7×10-5 and 23.2×10-5 mol/g at 295 K, respectively. The effect of sulfonate groups on the human hair surface can enhance the biosorption capacity of human hair as well as the elution efficiency of EDTA solution as eluent. The regenerated human hair samples with EDTA and rinsing later with water, showed good biosorption capacities of their reuse. So, the human hair is considered as a potential biosorbent for the removal of heavy metals from aqueous solutions. Based on the above results, we can confirm that H2 (bleached-dyed hair) shows the best biosorption capacity, which inspire us to properly chemically modify the human hair to enhance its biosorption capacity. So, native human hair was treated by a proper oxidation method, and its biosorption performance was evaluated and compared with the native one. The chemical composition and morphology of human hair were analyzed by FR-IR and SEM respectively, after the oxidation treatment as well as after the metal biosorption process. The treated human hair showed better biosorption capacity for heavy metals comparing with the untreated one, as expected, due to the higher surface area after the treatment, and more sulfonate groups present on the surface, which have been formed through the oxidation reaction. The parameters affecting the biosorption of heavy metals, such as contact time, initial aqueous pH value, biosorbent dosage and initial metal concentration have been investigated. According to the kinetics and isotherm studies, the rate limiting step of the biosorption process might be the chemical sorption due to the formation of chemical bonds between the metal ions and the functional groups of the treated human hair in monolayer coverage. The maximum biosorption capacity of the treated human hair for Cr(III), Cu(II), Cd(II) and Pb(II) by Langmuir isotherm model at 295 K are 9.47×10-5, 5.57×10-5, 3.77×10-5, 3.61×10-5 mol/g, respectively. Negative standard Gibb’s energy indicates that the heavy metal biosorption process is thermodynamically feasible and spontaneous nature. The sulfonate groups on the treated human hair formed in the oxidation treatment, not only enhance the biosorption capacity, but also assist the desorption of metal ions by using EDTA. In addition, the elution using EDTA is beneficial to its reuse. Thus, the human hair treated by the oxidation method exhibits satisfactory biosorption capacity and can be used as an effective biosorbent for the removal of heavy metals from aqueous solutions. Four common waste keratin biomaterials including human hair, dog hair, chicken feathers and degreased wool were used as biosorbents for the removal of heavy metals from aqueous solutions. The biosorption process was carried out under different conditions. The total biosorption capacity of the four biosorbents generally followed the order degreased wool > chicken feathers > human hair > dog hair. This is probably due to the partial oxidation of the degreased wool and the high surface area of chicken feathers, which are confirmed by FT-IR and SEM, respectively. Kinetic results indicated that chemical sorption is the basic mechanism in the biosorption processes. The experimental data fitted very well to the Langmuir isotherm model and the biosorption process is thermodynamically feasible and spontaneous nature, as indicated previously with the human hair case. These four keratin biomaterials regenerated with EDTA and rinsed with deionized water exhibit good biosorption capacity, especially for the chicken feathers (low cystine content) and the degreased wool (oxidized keratin fiber). The four waste keratin biomaterials, being cheap and easily available materials, could be an alternative to more costly adsorbents used nowadays for the heavy metals removal in wastewaters treatment processes. Based on these results, it can be said that keratin biomaterials can be used as potential biosorbents for the removal of heavy metals, and that the human hair treated with an oxidation procedure can enhance its biosorption capacity. Therefore, the other keratin biomaterials including dog hair, chicken feathers and degreased wool were also treated by using the same chemical modification method. The treated dog hair shows better biosorption capacity than the native one, with similar behavior to the treated human hair. However, the biosorption capacities of chicken feathers and degreased wool are not improved by this method, which is probably due to the condition of modification (especially for the wool that has been degreased previously) and the properties of the keratin biomaterials themselves. Therefore, further characterization of the treated dog hair is followed. Corresponding biosorption experiments with the treated dog hair were carried out to investigate the effect of different parameters, such as contact time, pH of the solution and biosorbent dosage, as in the previous cases of study. Kinetic and isotherm models were also used to fit the experimental data, the results indicate that the chemical sorption is the rate limiting step in the biosorption process. The maximum biosorption capacity of the treated dog hair for Pb(II) by the Langmuir isotherm model is 5.79×10-5 mol/g at 295 K. The treated dog hair shows a good reusability after simple elution with EDTA and rinsing with deionized water. In conclusion, the waste keratin biomaterials can be used as low-cost and effective biosorbents to remove heavy metals from aqueous solutions. In general, the oxidation treatment can significantly enhance the biosorption capacities of the keratin biomaterials. But the different conditions of the oxidation treatment for each keratin biomaterial should be considered for the proper modification in each case. These kinds of keratin biomaterials are expected to be applied in large scale to deal with the industrial wastewaters in near future.
102

Caracterització i aplicació de membranes de polisulfona i desenvolupament de noves membranes d’impressió molecular

Conesa Cabeza, Aleix 24 July 2015 (has links)
Els estudis realitzats en aquesta memòria tenen com a fonament tres blocs principals, tots tres centrats en un mateix objectiu: les membranes polimèriques. Aquets tres blocs són: la caracterització de les membranes, algunes aplicacions de les membranes i la síntesis de noves membranes. La caracterització de les membranes és la part més extensa de la memòria i s’ha realitzat amb dues perspectives diferenciables: Per una banda s’ha desenvolupat per primera vegada en el camp de les membranes, l’ús de la tècnica espectroscòpica d’infraroig proper (NIR) com a tècnica per poder distingir les membranes d’inversió de fase, segons si han estat preparades per evaporació o per immersió. Aquest mètode també permet classificar-les pel seu gruix, només realitzant un simple espectre d’infraroig proper de la superfície i aplicant-hi un mètode supervisat de modelatge basat en l’anàlisi de variança residual. Per una altra banda, s’han utilitzat tècniques habituals de caracterització de membranes com la Microscòpia Electrònica d’Escombrat (SEM), la Microscòpia de Força Atòmica (AFM), l’Espectroscòpia Electrònica per a l’Anàlisi Química (ESCA), les Espectroscòpies d’Infraroig (IR) o la Ressonància Magnètica Nuclear (RMN) amb l’objectiu d’estudiar les propietats físiques de les membranes. Concretament s’ha aprofundit en estudiar tres tipus de membranes polimèriques diferents: les membranes de polisulfona (PS), les membranes de polisulfona amb una capa de poliamida (PA), y les membranes d’impressió molecular (MIM). En el cas de les membranes de PS s’ha determinat quin es l’efecte d’algunes de les variables més importants que afecten a la formació de macrovoids durant la preparació d’aquestes membranes. Aquestes variables són: el gruix de membrana, la temperatura del bany de coagulació o la presència d’altres compostos químics com l’isopropil miristat (IPM) utilitzat com agent facilitador del transport. En el cas de les membranes de PS amb una capa de PA, s’ha realitzat un estudi de caracterització superficial per tal de conèixer la degradació d’aquestes membranes quan estan sotmeses a filtracions d’aigua oxigenada (H2O2) al 40%. Finalment, en el cas de les MIM s’han caracteritzat principalment per verificar la correcta formació d’aquestes membranes. Pel que fa al segon bloc sobre aplicacions de les membranes, els estudis s’han dirigit per una banda a la separació quiral dels enantiòmers D,L-propranolol i D,L-selenometionina mitjançant sistemes de diàlisis, i per l’altra banda a la reducció de la Demanda Química d’Oxigen (DQO) d’una solució d’aigua oxigenada al 40% mitjançant filtració frontal en discontinu. Més concretament, s’ha pogut comprovar que les membranes de polisulfona preparades per immersió i amb presencia d’IPM faciliten el transport per igual dels dos enantiòmers del propranolol, mentre que si a més hi afegim el compost N-hexadecil-L-hidroxiprolina (HHP) es produeix una certa enantioseparació. En el cas de la separació dels enantiomers de la D,L-selenometionina, s’ha pogut comprovar que la membrana formada pel copolímer N,N-dimetil-2-aminoetilmetacrilat ̶ etilenglicol dimetacrilat (DMAEM-EDMA) té capacitat d’interacció selectiva amb l’enantiòmer L de la selenometionina. Pel que fa la l’eliminació de la DQO en solucions de H2O2 s’ha demostrat que les membranes de nanofiltració de polisulfona amb una capa de poliamida poden disminuir la DQO de 500 ppm a 62 ppm. Finalment, en l’últim bloc destinat a la síntesis de noves membranes, s’ha realitzat la síntesis i caracterització de noves membranes preparades amb la tècnica de la impressió molecular. Per fer-ho s’han utilitzat tècniques com la polimerització per fixació radicalària utilitzant el benzoin etil èter (BEE) com a fotoiniciador sobre membranes de fluorur de polivinilidè hidrofòbic (PVDF-phob, Durapore), utilitzant 4 tipus diferents de monòmers diferents com són la 4-vinilpiridina (4VPY), l’àcid metacrílic (MAA), l’acrilamida (AAM) i el N,N-dimetil-2-aminoetilmetacrilat (DMAEM). / This thesis is divided in three sections, all of them focused on a common goal: polymeric membranes. These three sections are: the characterization of membranes, applications of the membranes and the synthesis of new membranes. Characterization of membranes is the most extensive section of this memory and has been made with two differentiated perspectives: On one hand, for the first time in the field of membranes, it has been developed the use of the Near Infrared Spectroscopic technique (NIR) as a technique to distinguish the phase inversion membranes, according if they have been prepared by evaporation or by immersion. This developed methodology also allows classifying them by their thickness, just doing a simple near infrared spectrum of the prepared membrane surface and applying a supervised modeling method based on the analysis of residual variance. On the other hand, usual techniques have been used for the characterization of membranes such as Scanning Electron Microscopy (SEM), Atomic Force Microscopy (AFM), Electron Spectroscopy for Chemical Analysis (ESCA), Infrared Spectroscopies (IR) or Nuclear Magnetic Resonance (NMR) with the aim of studying the physical properties of the membranes. Specifically, it has been studied in depth three different types of polymeric membranes: polysulfone membranes (PS), polysulfone membranes with a layer of Polyamide (PA), and molecularly imprinted membranes (MIM). In case of PS membranes, the effect of some of the most important variables that affect the formation of macrovoids during their preparation have been determined. These variables are: the membrane thickness, the temperature of the coagulation bath or the presence of other chemical substances such as isopropyl myristate (IPM) used as the carrier agent facilitator. In case of membranes with a layer of PA, it has been performed a surface characterization study, with the aim of take knowledge about the deterioration of these membranes after their use in filtration processes of 40 % of hydrogen peroxide (H2O2) solutions. Finally, the MIM have been characterized, mainly to verify their correct preparation procedure and final formation. In the second section, related with membrane applications, both chiral separation of D,L-propranolol and D,L-selenomethionine enantiomers using dialysis systems and, reduction of the Chemical Oxygen Demand (COD) of a 40% hydrogen peroxide solutions using a dead-end filtration system have been considered. More specifically, it has been proved that polysulfone membranes prepared by immersion, containing IPM, facilitate the transport of both enantiomers of propranolol, whereas if the compound N-hexadecyl-L-hydroxyproline (HHP) is also added into the membrane, a certain enantioseparation is accomplished. In case of the D,L-selenomethionine enantiomers, it has been proved that the membrane formed by the copolymer N,N-dimethyl-2-aminoethyl methacrylate ̶ ethylenglicol dimethacrylate (DMAEM-EDMA) has the capacity to interact selectively with the L enantiomer of selenomethionine. Regards to COD elimination in H2O2 solutions, it has been proved that polisulfone membranes of nanofiltration with a layer of polyamide can reduce the COD levels from 500 ppm to 62 ppm. Finally, the last section about synthesis of new membranes, comprises the synthesis and characterization of new membranes prepared by molecular imprinted technique. It has been used the technique of radical polymerization using benzoin ethyl eter (BEE) as a photoinitiator over a hydrophobic membrane of polyvinylidene fluoride (PVDF-phob, Durapore), using 4 different types of monomers such as 4-vinylpyridine (4VPY), methacrylic acid (MAA), acrylamide (AAM) and N,N-dimethyl-2-aminoethylmethacrylate (DMAEM).
103

Metabolomics and stoichiometry adapted to the study of environmental impacts on plants

Gargallo Garriga, Albert 10 September 2015 (has links)
La metabolòmica ha permès importants avanços en les ciències biològiques. Un nombre creixent d'estudis ecològics han aplicat un enfoc metabolòmic per respondre a preguntes ecològiques (ecometabolòmica) durant els últims anys. El treball desenvolupat al llarg d'aquesta tesi doctoral significa un pas més en el camp de la ecometabolòmica. En el primer capítol d'aquesta tesi doctoral, hem fet l'adaptació del protocol per dur a terme la metabolòmica en estudis ecològics. En ell es descriuen en detall els procediments per al camp i de laboratori per realitzar anàlisis de metabolòmica mitjançant la Ressonància Magnètica Nuclear (RMN) especroscòpica i cromatografia líquida amb espectrometria de masses (HPLC-MS), juntament amb l'anàlisi de l'estequiometria. Aquesta millora ens ha permès combinar l'estudi d'estequiometria ecològica i metabolòmica en un sol protocol i donar una visió general del que està passant amb els organismes. En el segon i tercer capítols s’ha aplicat el protocol sobre la part aèria i arrels en l’estudi dels efectes de factors relacionats amb el canvi climàtic (sequera, escalfament, els factors de risc). Els resultats confirmen la variació metabolòmica entre la part aèria i les arrels, en les diferents estacions de l’any i en diferents tractaments d'aigua. L'anàlisi ecometabolomic simultània entre la part aèria i les arrels ha proporcionat una visió completa de tota la planta, incloent la resposta dels diferents òrgans als canvis ambientals, la resposta global fenotípica i els mecanismes metabòlics subjacents a aquestes respostes. En el quart capítol es descriu la metabolòmica de fulles d’alzina (Quercus ilex) simulant un atac dels herbívors. El perfils de RMN de les fulles del Quercus ilex canvien després de la ferida. Es va observar, un marcat augment en els metabòlits secundaris rics en carboni, del quercitol i del àcid quínic, que estan relacionats amb la via metabòlica de l'àcid shiquímic. Els resultats també confirmen que l'àcid quínic i el quercitol són presents en gran contingut en el gènere Quercus i estan involucrats en els mecanismes contra factors biòtics. Finalment, el cinquè capítol estudia les relacions entre els microorganismes epífitics i la planta. L’estudi mostra que els microorganismes que viuen a la filosfera de la fulla juguen un paper important, existeixen microorganismes dins dels òrgans de la planta i les relacions que hi ha entre l’estructura i les funcions del metabolisme intern i extern de la planta. Aquests resultats aporten un major coneixement de les relacions específiques entre les plantes i les comunitats microbianes que viuen sobre i dins d'ells. / Metabolomics has allowed significant advances in biological sciences. An increasing number of ecological studies have applied a metabolomic approach to answer ecological questions (ecometabolomics) during the last few years. The work developed throughout this PhD thesis means a further step in the field of ecometabolomics. The first chapter of results of this thesis is dedicated to the adaptation of a previously described protocol to conduct metabolomics in ecological studies. It describes in detail the procedures to follow, in the field and in the laboratory, to perform metabolomic analyses using nuclear magnetic resonance (NMR) spectroscopy and liquid chromatography-mass spectrometry (LC-MS) coupled to stoichiometric analysis. This improvement allowed to combine the study of ecological stoichiometry and metabolomics in a single protocol and obtain a wider overview of what is happing to the organism. In the second and third chapters, the described protocol is applied to study how some climate change factors (drought, warming and irrigation) affect different organs of the plant (shoots and roots of Holcus lanatus and Alopecurus pratensis) at two different seasons. The results show a relationship between the metabolic variation observed in roots and the observed in shoots. The simultaneous metabolomic analysis of both organs of these grasses provide a complete view of the entire plant; including the response of different organs to environmental changes, the global phenotypic response and the metabolic mechanisms underlying these responses. The fourth chapter is dedicated to the study of the simulated attack to Quercus Ilex leaves by a herbivore. The results show differences in the 1H NMR metabolic profiles of the leaf before and after the wound. A marked increase in C-rich secondary metabolites, quinic acid and quercitol, which are related to the shikimic metabolic pathway, was observed. The results also confirm that quinic acid and quercitol are present in great content in the genus Quercus and they are involved in mechanisms against biotic stress. In the fifth chapter a study of the relationship between the epiphytic microorganisms and the plant host is described. This study highlights the large complexity of the episphere, the existence of internal microbial communities and the strong relationships between the structure and function of the internal and external plant metabolomes. These results warrant further study of the specific relationships between plants and the microbial communities living on and in them.
104

Advanced amperometric nanocomposite sensors based on carbon nanotubes and graphene: characterization, optimization, functionalization and applications

Muñoz Martín, Jose María 28 September 2015 (has links)
Dins de l’amplia gama de nanocompòsits, la incorporació de materials conductors de carboni nanoestructurats, entre els quals s’hi troben els nanotubs de carboni (NTCs) i el grafè, a dins d’una matriu polimèrica aïllant, és una forma molt atractiva de combinar les propietats mecàniques i elèctriques úniques del material de farciment amb els atributs dels plàstics. Concretament, els materials nanocompòsits basats en carboni han jugat un gran lideratge en el camp de l’electroquímica analítica, sobre tot en el desenvolupament de dispositius (bio)sensors, degut a les seves interessants avantatges respecte a un material conductor pur. Aquestes avantatges els hi proporcionen un alt valor afegit, com versatilitat, durabilitat, una fàcil regeneració de la superfície i integració, simplicitat a l’hora d’incorporar diferents (bio)modificadors o una baixa corrent de fons, entre d’altres. En aquest sentit, aquesta tesi aborda el desenvolupament de sensors nanocompòsits avançats de tipus amperomètrics que, havent sigut optimitzada la seva relació carboni/polímer, poden ser modificats amb un ampli ventall de nanopartícules (NPs) per millorar-ne la seva eficiència electroanalítica. Les propietats elèctriques d’aquests nanocompòsits i, per tant, la seva aplicabilitat analítica, es troben directament influenciades tant per la naturalesa de les partícules conductores com per la quantitat i distribució espacial de les mateixes a través de la matriu polimèrica aïllant. Una de les propietats electroquímiques més importants que envolten a aquests materials, és la similitud del seu comportament electroquímic amb el d’un array de microelèctrodes. Per tant, una optimització de la seva relació carboni/polímer respecte a la naturalesa del material conductor de partida, permetrà assolir una major dispersió de les àrees conductores a través de les zones no conductores, presentant així beneficis similars als d’un array de microelèctrodes. A més, és conegut que alguns paràmetres, tals com la resistivitat del material compost, la transferència electrònica, la robustesa del material i la corrent capacitiva es troben fortament influenciades per la naturalesa física de la mostra de nanotubs de partida, com és la seva relació longitud/diàmetre i la seva puresa, fet que poden influir fortament la resposta electroanalítica final del material transductor. Sota aquest context, la primera etapa de la Tesi va consistir en la implementació d’un conjunt de tècniques instrumentals que, aplicades de manera sistemàtica, han permès la caracterització i la optimització de la composició dels materials nanocompòsits basats en nanotubs de carboni i resina epoxi (Epotek H77) en relació a la naturalesa dels NTCs de partida per a la fabricació de sensors electroquímics més eficients. El protocol de caracterització dut a terme inclou eines elèctriques, electroquímiques, morfològiques, microscòpiques, espectroscòpiques i electro-analítiques. Un cop optimitzada les proporcions de CNT/epoxi, el següent pas va consistir en millorar el rendiment analític d’aquests sensors electroquímics nanocompòsits incorporant-ne diferents NPs per a la introducció d’algun tipus d’efecte electrocatalític. Per arribar a aquesta fita, es va desenvolupar una metodologia simple per a la síntesi d’una amplia gama de NPs. La Síntesi Intermatricial (IMS) va ser utilitzada com a tècnica verda per al disseny de tres rutes diferents que permetin una incorporació personalitzada d’aquestes NPs dintre del material transductor, obtenint així sensors amperomètrics més sensibles a diferents analits. Finalment, els estudis de caracterització i funcionalització implementats en els sensors nanocompòsits basats en NTCs han estat estesos a materials nanocompòsits basats en una altra forma al·lotròpica del carboni: el grafè, el qual és l’últim descobriment en termes de material de carboni nanoestructurat. / Entre la amplia gama de nanocompósitos, la incorporación de materiales conductores nanoestructurados de carbono, entre los que se encuentran los nanotubos de carbono (NTCs) y el grafeno, dentro de una matriz polimérica aislante, es una forma muy atractiva de combinar las propiedades mecánicas y eléctricas únicas del material de relleno con los atributos de los plásticos. Concretamente, los materiales nanocompósitos basados en carbono han jugado un gran liderazgo en el campo de la electroquímica analítica, sobre todo en el desarrollo de dispositivos (bio)sensores, debido a sus interesantes ventajas con respecto a un material conductor puro. Dichas ventajas les proporcionan un alto valor añadido, como versatilidad, durabilidad, fácil regeneración de la superficie e integración, simple incorporación de (bio)modificadores o baja corriente de fondo, entre otras. En este sentido, esta tesis aborda el desarrollo de sensores nanocompósitos avanzados de tipo amperométrico que, habiendo sido optimizada su relación carbono/polímero, pueden ser modificados con un amplio abanico de nanopartículas (NPs) para mejorar su eficiencia electroanalítica. Las propiedades eléctricas de estos nanocompósitos y, por lo tanto, su aplicabilidad analítica, están directamente influenciadas tanto por la naturaleza de las partículas conductoras como por la cantidad y distribución espacial de éstas a través de la matriz polimérica aislante. Una de las propiedades electroquímicas más importantes que envuelven a estos materiales es la similitud de su comportamiento electroquímico con respecto a un array de microelectrodos. Por lo tanto, una optimización de la relación carbono/polímero con respecto a la naturaleza del material conductor de partida permitirá lograr una mayor dispersión de las áreas conductoras a través de las zonas no conductoras, presentando beneficios similares a los de un array de microelectrodos. Además, es conocido que algunos parámetros, tales como la resistividad del material compuesto, la transferencia electrónica, la robustez del material y la corriente capacitiva están fuertemente influenciadas por la naturaleza física de la muestra de nanotubos de partida, como son su relación longitud/diámetro o su pureza, hecho que pueden influir fuertemente en la respuesta electroanalítica final del material transductor. Bajo este contexto, la primera etapa de esta tesis consistió en la implementación de un conjunto de técnicas instrumentales que, aplicadas de manera sistemática, han perimitido, la caracterización y optimización de la composición de materiales nanocompósitos basados en nanotubos de carbono y resina epoxi (Epotek H77) con respecto a la naturaleza de los NTCs de partida para la fabricación de sensores electroquímicos más eficientes. El protocolo de caracterización llevado a cabo incluye herramientas eléctricas, electroquímicas, morfológicas, microscópicas, espectroscópicas y electroanalíticas. Una vez optimizada las proporciones de NTC/epoxi, el siguiente paso consistió en mejorar el rendimiento analítico de estos sensores electroquímicos nanocompósitos incorporándoles diferentes NPs con la finalidad de introducir algún tipo de efecto electrocatalítico. Para alcanzar este objetivo, se desarrolló una metodología simple para la síntesis de una amplia gama de NPs. La Síntesis Intermatricial (IMS) fue utilizada como técnica verde para el diseño de tres rutas diferentes que permitan una incorporación personalizada de estas NPs en el material transductor, obteniendo así sensores amperométricos más sensibles a diferentes analitos. Finalmente, los estudios de caracterización y funcionalización implementados en los sensores nanocompósitos basados en NTCs han sido extendidos para materiales nanocompósitos basados en otra forma alotrópica del carbono: el grafeno, el cual es el último descubrimiento en términos de material de carbono nanoestructurado. / Among the wide range of nanocomposites, the incorporation of conducting nanostructured carbon materials, such as carbon nanotubes (CNTs) and graphene, into an insulating polymeric matrix is a very attractive way to combine the unique mechanical and electrical properties of individual filler with the advantages of plastics. Concretely, carbon–based nanocomposite materials have played a leading role in the analytical electrochemistry field, particularly in (bio)sensor devices, due to their interesting advantages regarding to a pure conductive material, such as versatility, durability, easy surface regeneration and integration, facile incorporation of a variety of (bio)modifiers or low background current, among others. Accordingly, this thesis tackles the development of advanced amperometric nanocomposite sensors that having been optimized regarding to carbon/polymer composition ratios, can be tunable with different types of nanoparticles (NPs) for improving their electroanalytical efficiency. The electrical properties of these nanocomposites and, therefore, their analytical applicability, are directly influenced by the conducting particles nature and the amount and spatial distribution of them through the insulating polymeric matrix. One of the most important electrochemical properties of these materials is the similarity of their electrochemical behavior with a microelectrode array. Thus, an optimization of the carbon/polymer ratio with respect to the nature of the conducting material will allow to achieve a greater dispersion of the conducting areas through the non-conducting areas, presenting similar benefits to the microelectrode array. In addition, it is known that some parameters, such as composite resistivity, heterogeneous electron transfer rate, material robustness and background capacitance current are strongly influenced by the physical nature of the raw CNT sample, such as their diameter/length ratio and purity, fact that may strongly influences the final electroanalytical response of the transducer material. Under this context, the first step of this thesis consisted of implementing a group of instrumental techniques that, systematically applied, have allowed the characterization and optimization of nanocomposite materials composition based on CNTs and epoxy resin (Epotek H77) in relation to the nature of the raw CNT sample for the fabrication of more efficient electrochemical sensors. The developed characterization protocol includes electrical, electrochemical, morphological, microscopic, spectroscopic and electroanalytical tools. Having been optimized the MWCNT/epoxy composition ratios, the next step consisted of enhancing the analytical performance of these electrochemical nanocomposite sensors introducing some electrocatalytical effect by the incorporation of different NPs. For this goal, a simple methodology for synthesizing a wide range of different NPs has been developed. Intermatrix Synthesis (IMS) has been used as a green technique to design three different routes for CNT/epoxy nanocomposite electrodes modification, which offer a customized way for the preparation of sensitive amperometric sensors. Finally, the characterization and functionalization studies applied for CNT–based electrochemical nanocomposite sensors have been extended for nanocomposite materials based on another allotropic form of carbon: the graphene, which is the last discovery in terms of nanostructured carbon material.
105

Métodos automáticos de análisis para la determinación de parámetros de interés ambiental

Henríquez Hernández, Camelia 05 July 2013 (has links)
El incremento del vertido de sustancias contaminantes al medio ambiente, debido al desarrollo industrial y los malos hábitos de consumo, han provocado la ruptura del equilibrio de muchos ecosistemas llegando afectar, en muchas ocasiones, a los humanos. Con el objetivo de controlar y disminuir estos efectos, los gobiernos han dirigido acciones para legislar y regular el vertido de sustancias tóxicas al medio. De esta manera el Gobierno Nacional de España ha financiado a nuestro grupo de investigación, el proyecto del Plan Nacional en Ciencia y Tecnología Química titulado “Desarrollo de métodos automáticos de análisis. Aplicación a planes de vigilancia ambiental”, con referencia CTQ 2010-15541. La presente tesis forma parte de este proyecto siendo su objetivo general el desarrollo de nuevos métodos automáticos para la determinación de especies químicas de interés ambiental. En la introducción de la tesis se realiza una revisión sobre la automatización del laboratorio químico mediante técnicas de análisis en flujo y se describen las dos utilizadas en esta tesis. Seguidamente se revisa la aplicación de estas técnicas a la automatización de los métodos electroquímicos, especialmente la conductimetría y la voltamperometría redisolución anódica. En el tercer apartado de la introducción se recogen los aportes de las técnicas de flujo en la automatización de procesos de tratamientos de muestras como la difusión gaseosa y la extracción líquido-líquido. De esta última técnica se resume su evolución histórica hasta los métodos más recientes descritos que logran la automatización total del proceso de extracción y que se pudieran clasificar dentro de la tercera generación de las técnicas en flujo. En el último apartado de la introducción se trata la automatización de métodos cinético-catalíticos mediante técnicas de análisis en flujo, destacando el elevado potencial que tienen estos métodos para el análisis de trazas y el bajo número de trabajos publicados donde se consigue la automatización de los mismos. Contenido de la investigación En esta tesis se han utilizado dos técnicas de análisis en flujo, el análisis por inyección en flujo multijeringa (MSFIA) y los sistemas en flujo multibombas (MPFS), acopladas a dos métodos de tratamiento de muestras, la difusión gaseosa y la extracción líquido-líquido, y tres técnicas de detección, la voltamperometría de redisolución anódica, la conductimetría y la espectrofotometría, para obtener cinco sistemas automáticos de análisis. Los sistemas desarrollados han sido aplicados a la determinación, fundamentalmente en agua de mar, de cinco analitos inorgánicos: cadmio, cromato, yoduro, amonio y carbono inorgánico total, en muestras ambientales. Durante el desarrollo de estos sistemas y el estudio de las técnicas utilizadas, se han solucionado problemas relacionados con la automatización de las técnicas en flujo, lo que ha mejorado significativamente las características analíticas de los métodos presentados en comparación con otros similares reportados en la literatura. Entre estas mejoras se encuentran por ejemplo el incremento de la reproducibilidad y sensibilidad de las determinaciones, la disminución de los volúmenes de reactivos y muestras utilizados, la reducción de las dimensiones del sistema y de los costes de la instrumentación, así como el aumento del grado de automatización del proceso analítico: tratamiento de la muestra, calibración y detección. Los trabajos presentados en esta tesis son los siguientes: 1- Un método simple, económico, portátil y automatizado mediante MSFIA que permite la determinación de cadmio mediante voltamperometria de redisolución anódica usando electrodos impresos con película de bismuto. (SPE- BiF-ASV- SFIA) 2- Un sistema automatizado mediante la técnica de MSFIA para la determinación de amonio en muestras de aguas naturales y marinas utilizando la difusión gaseosa y la detección conductimétrica. (C-GD-MSFIA) 3- Un analizador automático, basado en la técnica de MPFS, para la determinación de amonio y de carbono inorgánico total en muestras de aguas marinas usando difusión gaseosa y detección conductimétrica. (C-GD-MPFS) 4- Un sistema totalmente automatizado de microextraccion líquido-líquido dentro de la jeringa de una bureta automática para la determinación espectrofotométrica de cromo (VI) en muestras de aguas naturales. (In syringe-MSA-DLLME) 5- Un chip conductor de microfluidos para la automatización mediante MSFIA de un método cinético-catalíticos que permita el análisis de ioduro en agua de mar y fármacos con un consumo muy reducido de reactivos. (CHIP-MSFIA-Catalytic) Conclusiones Se han desarrollado nuevos sistemas automáticos para la determinación de analitos inorgánicos de interés ambiental. La utilización de técnicas de análisis en flujo multiconmutadas, como MSFIA y MPFS, han demostrado ser muy útiles en la automatización de sistemas de análisis que utilizan diferentes técnicas de detección (electroquímicas y espectrofotométricas), de pretratamiento de muestra y de métodos de determinación cinéticocatalíticos. Los sistemas desarrollados han demostrado su efectividad en la determinación de analitos inorgánicos (cadmio, cromato, yoduro, amonio y carbono inorgánico total) en muestras tan complejas como las aguas de mar, aguas residuales o preparados farmacéuticos. Bibliografía 1.Henríquez C, Laglera LM, Alpizar MJ, Calvo J, Arduini F, Cerdà V: Cadmium determination in natural water samples with an automatic multisyringe flow injection system coupled to a flow-through screen printed electrode. Talanta 2012, 96(0):140-146. 2.Henríquez C, Horstkotte B, Cerdá V: Conductimetric determination of ammonium by a multisyringe flow injection system applying gas diffusion Int J Environ Anal Chem 2012:1-17. 3.Henríquez C, Horstkotte B, Cerdá V: A highly reproducible and robust solenoid micropump system for the analysis of total inorganic carbon and ammonium using gas diffusion with conductometric detection. Talanta 2013, In review 4.Henríquez C, Horstkotte B, Solich P, Cerdá V: In-syringe magnetic stirring assisted liquid-liquid microextraction for spectrophotometric determination of Cr (VI) in waters. Analytical and Bioanalytical Chemistry 2013, Accepted/in press. 5.Abouhiat FZ, Henríquez C, Horstkotte B, El Yousfi F, Cerdà V: A miniaturized analyzer for the catalytic determination of iodide in seawater and pharmaceutical samples. Talanta 2013, 108(0):92-102. / Introducción The increasing discharge of pollutants into the environment due to the industrial development and consumer habits have caused the increasing unbalance of many ecosystems, already affecting in many occasions human species itself. In order to control and reduce these effects, many governments have initiated actions to control the discharge of toxic substances into the environment. In this way, the Spanish Government has funded, to our research group, the project of the National Science and Technology Chemistry entitled “Development of automated methods of analysis. Application to environmental monitoring plans”, with reference CTQ 2010- 15541. This PhD thesis is part of this overall project with the main objective of the development of new automated methods for the determination of some chemical species of environmental interest. In the first part of the introduction of this thesis, the automation of different procedures in a chemical laboratory by the use of flow techniques is reviewed and the two selected flow techniques are described. In the second section, the application of these techniques in the automation of electrochemical methods, especially conductometry and anodic stripping voltammetry, is reviewed. In the third section of the introduction, the contributions of flow techniques to the automation sample pretreatment are discussed, especially for gaseous diffusion and liquid-liquid extraction. Moreover, it was reviewed the historical evolution and the most recent reported methods to achieve the full automation of liquid-liquid extraction inside the syringe, which could be classified as the third generation of flow techniques. The last part of the introduction deals with the automation of kinetic-catalytic methods using flow techniques, emphasizing the high potential of these methods for trace analysis and the low number of published papers on this subject. Research content. In this thesis, two flow techniques, MSFIA and MPFS, coupled to two sample pretreatment methods, gas diffusion and liquid-liquid extraction, and three detection techniques, anodic stripping voltammetry, conductometry and spectrophotometry, have been used to develop five automatic analytical systems. These systems have been applied to the determination of five inorganic analytes: cadmium, chromate, iodide, ammonium, and total inorganic carbon and applied to different environmental water samples with main focus on seawater. Involved in the development of these systems were the study of the used techniques and the finding of solutions for the problems related to the automation using flow techniques. Significant improvements of the analytical characteristics of the presented methods in comparison with similar ones reported in the literature are obtained. These improvement were an increase of the reproducibility and sensitivity of measurement, the decrease of reagent and sample consumption, the reduction of the analyzers’ sizes and instrumentation costs, and further, an increase of the automation degree of the analytical procedure, including: sample pretreatment, calibration and detection. The presented contributions are listed below: 1- A simple, economic, automated, and portable analyzer system based on MSFIA, which allows the determination of cadmium with anodic stripping voltammetry using a bismuth film coated screen printed electrode. (SPE-BiF-MSFIA) 2- An automatic MSFIA system for the determination of ammonium in naturals and seawaters in a very wide concentration range using gas diffusion and conductometric detection. (C-GD-MSFIA) 3- An automated and highly reproducible analyzer based on MPFS for the determination of total inorganic carbon and ammonium in seawaters using gas diffusion and conductometric detection. (C-GD-MPFS) 4- A fully automated in-syringe magnetic stirred-assisted dispersive liquid-liquid microextraction system for the spectrophotometric determination of chromate in natural waters. (In syringe-MSA-DLLME) 5- A microfluidic “Chip” conductor to be used in combination with MSFIA for the automated quantification of iodide in seawaters and pharmaceutical preparations using a kinetic-catalytic method characterized by a very low reagent and sample consumption. (CHIP-MSFIA-Catalytic) Conclusions Five new systems have been developed for the automatic determination of inorganic analytes of environmental interest. The use of the multi-commutated flow techniques MSFIA and MPFS has proven to be very useful for the automation of the analytical systems, coupling to different detection techniques, as well as sample pretreatment and kinetic-catalytic determinations. The developed systems have been confirmed to be efficient for the determination of inorganic analytes in complex sample matrices such as seawater, wastewater, or pharmaceutical preparations.
106

Desarrollo de un sistema modular de membranas líquidas para la separación y determinación de lantánidos, utilizando el ácido di(2-etilhexil) fosfórico como transportador

Cara Flores, Gabriel Miguel 30 April 2013 (has links)
Los lantánidos constituyen un grupo de metales fascinante, con unas propiedades químicas muy similares. Aunque no es posible encontrarlos como constituyentes principales de los productos usados a diario, están detrás de toda la revolución tecnológica de la miniaturización electrónica actual. Debido a la similitud de sus propiedades químicas y de los procesos de formación de sus minerales, la separación de estos elementos ha constituido desde su descubrimiento un gran reto. Nuestro trabajo se enfoca en la búsqueda de métodos de separación empleando la extracción líquido-líquido en un soporte polimérico en formato tubular. Se escoge el neodimio como representante de los lantánidos y D2EHPA como agente extractante. Se estudian los parámetros que influyen en la cinética de su extracción empleando una membrana líquida de volumen. Se calculan las constantes de velocidad del transporte de neodimio y holmio a través de la membrana líquida. Se estudia la influencia del pH de la disolución cargada, la concentración inicial de metal y la presencia de una sustancia tampón en la disolución cargada que luego serán aplicados en las diversas configuraciones de membrana líquida estudiados. Se desarrolla un modulo de vidrio y PVDF con una membrana líquida soportada en una fibra hueca. Se emplea para conseguir la concentración de neodimio y en la separación de éste del holmio. Se analizan las características hidrodinámicas del sistema para maximizar el transporte empleando la permeabilidad como parámetro de seguimiento del transporte del metal. Se encuentra que para la misma velocidad lineal el transporte se ve más favorecido cuando el metal se transporta desde el interior hacia el exterior de la fibra hueca. Se observa que en las condiciones estudiadas el neodimio efectivamente se transporta mientras que el holmio se queda retenido en la membrana líquida. Con los parámetros anteriores se desarrolla un módulo concentrador en línea para determinar cantidades reducidas de neodimio en un sistema FIA. Se emplea el mismo lado de la membrana líquida soportada para la realización de los fenómenos de extracción y reextracción. Se alcanzan límites de detección del orden de 100 veces los límites atribuibles al sistema de determinación por sí solo. Es posible determinar neodimio en presencia de lantánidos pesados y algunos elementos como calcio, níquel, zinc, cobre y magnesio que también son extraidos habitualmente con D2EHPA. No es posible hacerlo cuando se trata de lantánidos del grupo de los ligeros y de hierro que presentan una interferencia muy elevada. Para poder evaluar la concentración de metal en las disoluciones acuosas, se emplearon dos métodos de análisis. Por una parte un sistema FIA con un método colorimétrico con Arsenazo III que permite el análisis de muestras con un pH muy diferente entre ellas, gracias al uso de un canal neutralizador con un tampón. Por otra un sistema HPLC con una columna modificada dinámicamente con DDS y utilizando una fase reversa con HIBA, que permite el análisis de todos los elementos lantánidos en muestras que los contienen a todos ellos. Se aplica al análisis de muestras reales de mineral de bastnasita. Se desarrolla un módulo de vidrio con una membrana líquida de volumen, contenida en una fibra hueca, que permite la concentración y separación en continuo de tierras raras empleando D2EHPA como extractante. Se produce la recuperación efectiva en un alto grado de eficacia de neodimio incluso con tiempos cortos de contacto. En las condiciones estudiadas no es posible la separación de los diferentes lantánidos. / The lanthanides are a fascinating group of metals, with very similar chemical properties. Even it is not possible to find them as main constituents of products used on a daily basis, they are behind all the technological revolution of the nowadays electronic miniaturization. Due to the similarity of their chemical properties and the processes of formation of their ores, separation of these elements has constituted a great challenge since its discovery. Our work focuses on the search for methods of separation using the liquid-liquid extraction in a polymeric support in tubular form. As representative of the lanthanides neodymium and D2EHPA as extraction agent is chosen. We study the parameters influencing the kinetics of extraction using a bulk liquid membrane. The speed constants of the transport through the liquid membrane of neodymium and holmium are calculated. It is discussed the influence of the pH, the initial concentration of metal and the presence of a buffer substance in feed solution that then will be applied in the different configurations of liquid membrane studied. It is developed a glass and PVDF module with a hollow fibre supported liquid membrane inside. It is used to achieve the concentration of neodymium and its separation from holmium. The hydrodynamic characteristics of the system are analyzed to maximize transport using the permeability as a parameter of the transport of metal tracking. It is found that, for the same linear speed, transport is favoured when metal goes from the lumen towards the shell of the hollow fibre. It is observed that in the studied conditions neodymium is actually transported while the holmium is retained in the liquid membrane. With the previous parameters an in line concentrator module is developed for determining small amounts of neodymium with a FIA system. It employs the same side of the supported liquid membrane to carry out extraction and re-extraction phenomena. It reaches limits of detection of the order of 100 times attributable to the system determination limits itself only. It is possible to determine neodymium in the presence of heavy lanthanides and some elements like calcium, nickel, zinc, copper and magnesium which are also commonly extracted with D2EHPA. It is not possible to do so with iron and the light lanthanides group that present a very high interference. Two methods of analysis were used to evaluate the concentration of metal in aqueous solutions. On the one hand a FIA system with a colorimetric method with Arsenazo III that allows the analysis of samples with a very different pH between them, thanks to the use of a buffer neutralization channel. On the other hand an HPLC system with a column dynamically modified with DDS and using a reversed phase with HIBA, which allows the analysis individual lanthanide elements in samples containing all of them. That is applied to the analysis of real samples of bastnasite ore. It is developed a glass module with a bulk liquid membrane, contained in a hollow fibre, which allows the concentration and continuous separation of rare earths using D2EHPA as extracting agent. It is achieved the effective recovery in a high degree of neodymium even with short contact times. The separation of the different lanthanides is not possible under the conditions studied.
107

Nano/micromaterials and motors in (bio)sensing applications

Guix Noguera, Maria 15 July 2013 (has links)
El disseny i la caracterització de plataformes analítiques i miniaturitzades, modificades amb diferents nanomaterials (tals com nanotubs de carboni o nanocables), s’ha portat a terme per a la seva posterior aplicació en la detecció de diversos analits d’interès (com per exemple fenol, glucosa, o la captura d’oli). Cal destacar que en alguns casos les plataformes sensores s’han modificat prèviament amb entitats biològiques que aporten selectivitat i sensitivitat a l’estudi analític. Referent als processos en absència de flux (mode batch), el elèctrodes serigrafiats de capa gruixuda (screen-printed electrodes, SPE) s’han modificat amb nanotubs de carboni, demonstrant un comportament analític excepcional per a aplicacions mediambientals. La detecció de fenol, modificat amb l’enzim de Tyrosinasa, va ser caractertizat mitjançant diferents tècniques de microscòpia com SEM, TEM o microscòpia confocal (CSLM), les quals van permetre obtenir una sèrie de dades estadístiques referents a la morfologia del material, alhora que van permetre determinar la distribució de la Tyrosinasa en la matriu sensora. Es van estudiar diferents mètodes d’immobilització, a més a més de ser implementat en un sistema de d’anàlisi per injecció en flux. A més a més, els SPE modificats amb nanocables d’or i plata, donant lloc a una plataforma sensor de glucosa que treballa en absència d’enzim, mitjançant la mesura de corrent produïa per l’oxidació directa de la glucosa sobre la superfície de l’elèctrode. Els estudis es van portar a terme a partir de la implementació de tècniques de cronoimpedància. El desenvolupament de noves plataformes nanoestructurades preparades a partir de la deposició alternada de nanopartícules de Prussian Blue, prèviament modificades amb ciclodextrina, amb polyallylamine (PAH) va permetre la creació d’una estructura supramolecular microcúbica. Aquestes plataformes presenten un comportament molt interessant electroquímicament, ja que els seus pics de corrent catòdics i anòdics augmenten amb el número de bicapes, indicant que efectivament les nanopartícules estan connectades elèctricament entre les multicapes. Cal destacar també la combinació de partícules paramagnètiques en un microchip d’electroforesis. Mitjançant la combinació d’un camp magnètic extern, l’electroforesis i tècniques electroquímiques, es va aconseguir la detecció de fenol (com a indicació de la immunodetecció). En aquest cas concret la detecció de fenol es va portar a terme per a seguir la hidròlisis de la phenol phosphate portat a terme per l’enzim alkaline phosphatase (AP) (immobilitat en les partícules magnètiques). El sistema requereix molt poc volum de mostra, alhora que presenta molts avantatges per a la seva versatilitat i per ser un sistema miniaturitzat que permet la renovació del la plataforma immunoespecífica. Finalment, s’ha desenvolupat una plataforma dinàmica a partir de la implementació de motors a la nano/microescala per a aplicacions mediambientals, a partir de la creació d’una superfície exterior superhidrofòbica que interactua amb substàncies olioses capturant-les. El desenvolupament de diferents plataformes, a més a més de la posterior integració de nano/micromaterials que han millorat significativament el seu comportament a nivell analític, ha mostrat resultats excel·lents en la detecció d’analits d’interès ambiental i mediambiental, projectant-se com a un element clau en sistemes monitoritzats i altres plataformes analítiques d’interès. / The design and characterization of novel miniaturized (bio)sensing platforms and devices modified with different nanomaterials, such as carbon nanotubes or nanowires, have been achieved. These platforms and devices have been applied in the detection of various analytes (e.g. phenol, glucose, oil droplets), in some cases closely related to the previously immobilization of biological entities that confer selectivity and sensitivity to the analytical platform. Regarding batch platforms, screen-printed electrodes (SPE) modified with carbon-nanotubes has demonstrated to be a potential analytical platform for environmental purposes by being applied for phenol detection in case of being modified by tyrosinase enzyme. The characterization of modified SPE by SEM, TEM and Confocal Scanning Laser Microscopy (CSLM) has brought the necessary statistical data over the morphological properties of the nano/micromaterials treated and the distribution of tyrosinase enzyme along the sensor matrix. Several immobilization approaches have been developed and the present system has been integrated in a Flow Injection Analysis (FIA). Additionally, carbon nanotubes modified SPE with gold-silver nanowires has resulted in a non-enzymatic electrochemical glucose sensor, based on the measurement of the current response during the direct glucose oxidation on the electrode surface by chronoimpedance technique (CIT) studies. The development of novel assembled nanoplatform taking advantage of layer by layer depositions from Prussian blue (PB) - cyclodextrin (CD) nanoparticles (NPs) with polyallylamine (PAH) was designed, showing a microcubic supramolecular like organitzation. Such platforms present interesting electrochemical behaviour, as the cathodic and anodic peak currents increased with the number of bilayers, indicating that PB nanoparticles are electrically connected within multilayers. Moreover, the combination of paramagnetic particles with microchip electrophoresis, external magnetic field manipulations, and coupled to EC detection permitted the detection of phenol (as indicator for immunodetection) by using low reagent consumption, in addition to the inherent miniaturization and versatility of such miniaturized system. Phenol detection was achieved by following the hydrolysis of phenyl phosphate by alkaline phosphatase (AP) enzyme linked to the magnetic beads (MBs), which resulted in a very interesting system due to the possibility to renew the immuno-specific support. Finally, an alternative and dynamic analytical platform was developed through the implementation of artificial nano/microscale machines for environmental remediation applications based on the creation of a superhydrophobic outer surface to strongly interact and capture oily liquids has been achieved. The development of different platforms, along with the wide range of nano/micromaterials integrated on them as to improve their analytical performance, have shown good results towards the detection of analytes of interest in health and environmental issues, being envisioned future key components of monitoring systems and other analytic platforms of interest.
108

Estudo do comportamento eletroquímico de alguns agentes antifúngicos utilizando polarografia de pulso diferencial e voltametria de redissolução catódica /

Pereira, Francisco Claudece. January 1999 (has links)
Orientador: Maria Valnie Boldrin Zanoni / Banca: Hideko Yamanaka / Banca: Mauro Bertotti / Resumo: O comportamento voltamétrico de dois agentes antifúngicos denominados de Clotrimazol e Miconazol foi investigado em meio hidrometanólico sobre eletrodo de mercúrio. Clotrimazol e miconazol são reduzidos em potencial bastante negativo em solução tampão B-R pH > 6 através da transferência reversível de 1 elétron à ligação C-Cl, cujo mecanismo de redução foi investigado através de PPD e VC. Para a determinação destes compostos em meio aquoso, recomenda-se a adição de 0,001% de Triton X-100 através da qual obteve-se uma curva de calibração linear entre 5x10- 6 a 2,8x10- 4 mol.L- 1 para clotrimazol em solução tampão fosfato pH 6,9 e para miconazol 192,0 a 718,5 ng.mL- 1 em solução tampão B-R pH 8,0 Um novo método para determinação indireta de clotrimazol através da técnica polarográfica de pulso diferencial foi investigado através da reação de derivatização do fármaco com o corante reativo Procion Red HE-3B (RR 120). O produto da reação entre a função clorotriazina do corante e clotrimazol...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Clotrimazole is reduced at mercury electrode above pH 6 involving a reversible one-electron process. The electrodic process presents a large contribution of the adsorption effects. For the differential pulse polarographic determination is recommended the addition of Triton X-100, which promotes a linear calibration curve from 5x10- 6 mol.L- 1 to 2,8x10- 4mol. L- 1. In addition, clotrimazole can be determined by cathodic stripping voltammetry at 5ng.mL- 1 level when pre-accumulated for 1 min at an accumulation potential of -0,2V. The proposed method have shown a linear calibration curve from 103 to 345ng.mL- 1 and can be applied successfully for the determination of the clotrimazole in commercial formulations. Interaction of the clotrimazole with reactive dye Procion Red HE-3B (RR 120) was investigated in aqueous solution by differential pulse polarography. The clotrimazole derivatized with the reactive dye in B-R buffer (pH 2) yielded a sensitive polarographic response at -0,38V (vs Ag/AgCl). Analytical parameters such as pH, buffer compositions, temperature, reaction time and concentration of dye have been optimised. Linear calibration curves for clotrimazole have been construted from 10-34 μg.mL- 1 using 1x10- 4 mol.L- 1 of the dye at room temperature. The method has been applied to the determination of clotrimazole in pharmaceutical preparations...(Complete abstract, click electronic access below) / Mestre
109

Resíduos de pesticidas organoclorados e bifenilas policloradas em compostos de resíduos sólidos urbanos : metodologia e aplicação /

Lourencetti, Carolina. January 2004 (has links)
Resumo: Os resíduos sólidos urbanos (RSU) têm se tornado um problema relevante, principalmente na última década, devido a grande quantidade gerada e as limitações de área para sua disposição. Além da reciclagem de materiais como papel, plástico e vidro, a compostagem, processo de degradação e humificação da matéria orgânica, é uma forma de tratamento desses resíduos e tem como objetivo a reutilização da fração orgânica através do seu produto final o composto. O uso do composto para fins agrícolas tem sido considerado promissor por pesquisas recentes. Pelo fato do composto ser lançado ao ambiente é fundamental a avaliação da sua qualidade, o que envolve investigação de alguns parâmetros já bem estabelecidos, tais como: pH, umidade, matéria orgânica, nitrogênio total e relação C/N. Entretanto, a presença de contaminantes orgânicos persistentes, como pesticidas organoclorados e bifenilas policloradas, tem sido pouco estudada nesta matriz. Tendo em vista as considerações acima descritas, este trabalho teve como objetivos desenvolver e validar um método analítico simples e eficiente para a determinação simultânea de resíduos de dez pesticidas organoclorados (α-HCH, β-HCH, γ-HCH, p,p'-DDT, o,p'-DDT, p,p'- DDD, p,p'-DDE, aldrin, endrin, dieldrin) e seis congêneres das bifenilas policloradas (PCB 28, 52, 118, 138, 153 e 180) no composto de RSU e avaliar a presença desses contaminantes em amostras de composto de algumas usinas de compostagem do Estado de São Paulo. O procedimento em pequena escala proposto baseia-se na extração e purificação de 1,0g da matriz em uma única etapa, empregando extração em fase sólida com alumina (2g) e celite (1g) e eluição com n-hexano:diclorometano (7:3). Após concentração do eluato enxofre foi eliminado com cobre em pó ativado. A análise foi realizada por GC-ECD empregando o método do padrão externo...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Municipal solid waste has been a significant problem, mainly in the last decade, due to the large amount produced and the limited places for it to be deposited. Besides the recycling of materials such as paper, plastic, and glass, the composting, process of degradation and humification of organic matter, is a way to treat those wastes and its purpose is to reutilize the organic fraction through the final product, the compost. Recent research has deemed the use of compost in agriculture as being promising. Considering the fact that compost is strewn upon the environment, its quality evaluation is fundamental, which involves investigation of some parameters already established, such as: pH, moisture, organic matter, total nitrogen and C/N ratio. However, in this matrix, the presence of persistent organic pollutants such as organochlorine pesticides and polychlorinated biphenyls have been studied little. Taking into consideration the parameters described above, the aims of this study were to develop and validate a simple and efficient method for the simultaneous determination of ten organochlorine pesticides (α-HCH, β-HCH, γ-HCH, p,p'-DDT, o,p'-DDT, p,p'-DDD, p,p'-DDE, aldrin, endrin, and dieldrin) and six congeners PCBs (PCB 28, 52, 118, 138, 153, and 180) in municipal solid waste compost and evaluate the presence of these contaminants in compost samples from some São Paulo State composting plants. The proposed small-scale method combines extraction and clean-up of matrix (1g) in a single step involving solid phase extraction with alumina (2g) and celite (1g) and hexane:dichloromethane (7:3). After eluate concentration, sulphur is removed with active copper. The analysis is performed by GC-ECD using external standard mode for quantitation...(Complete abstract click electronic access below) / Orientador: Mary Rosa Rodrigues de Marchi / Coorientador: Maria Lúcia Ribeiro / Banca: Eny Maria Vieira / Banca: Luciana Polese / Mestre
110

Desenvolvimento de método analítico para a determinação de vanádio em material vegetal por espectrometria de absorção atômica em forno de grafite /

Ambrozini, Beatriz January 2007 (has links)
Orientador: José Anchieta Gomes Neto / Banca: Luis Vitor Silva do Sacramento / Banca: Marco Aurélio Zezzi Arruda / Resumo: Os modificadores químicos W, Rh e BaF2 foram avaliados no desenvolvimento de método analítico para a determinação de vanádio em material vegetal por espectrometria e absorção atômica simultânea em forno de grafite. O comportamento térmico do vanádio foi estudado por meio de curvas de temperatura de pirólise e de atomização em meio de uma matriz composta pela suspensão de fragmentos de folhas ou raízes de plantas de salsinha (Petroselinum sp). Os melhores comportamentos de vanádio foram observados quando não se usa modificador e para o BaF2. Curvas analíticas (0,0 a 50 æg L-1 V) construídas por compatibilização de matriz forneceram boas correlações lineares (r2= 0,9989). As concentrações de vanádio em salsinhas cultivadas via hidroponia variaram de 0,69 a 2,23 ?g g-1. Os resultados obtidos para o material vegetal analisado com e sem modificador foram concordantes ao nível de 95% de confiança.Os limites de detecção (LOD) foram 0,94 e 0,74 ?g L-1, sem e com modificador, respectivamente. O desvio padrão relativo (r.s.d) foi 4,2% (sem modificador) e 2,6% (BaF2) e as respectivas massas características foram 17 pg V e 15,8 pg V. Dois materiais de referência certificados da National Institute of Standards and Technology (Tomato leaves 1573a e Spinach Leaves 1570a) foram analisados e os valores encontrados foram concordantes ao nível de 95% de confiança com os valores certificados. A validação dos métodos desenvolvidos envolveu o emprego do estudo de adição e recuperação de padrão. As recuperações variaram de 93 a 108% e de 88 a 102%, sem e com modificador, respectivamente. O emprego de BaF2 não eliminou os efeitos de memória causados pela formação de carbetos de vanádio refratários na plataforma do tubo de grafite. / Abstract: Diferent chemical modifiers were evaluated at the development of analytical method to determinate vanadium in garden parsley samples enriched with vanadium by hydroponic system by graphite furnace atomic absorption spectrometry (GF AAS) technique. The electrothermal behavior of V was studied by means of pyrolysis and atomization temperature curves in the garden parsley matrix. The evaluated modifiers were: W, Rh, BaF2 and modifier absence. The V better behaviors were observed for the BaF2 modifier and in the absence of modifier, once they presented better transient signal profiles, better r.s.d and better characteristic masses were obtained. Analytical curves were built within 0,0-50,0 æg L-1 interval using matrix matching calibration. Digest samples were employed to help the validation of the method. The V concentrations at the aerial parts of the garden parsley varied from 0,7 to 2,23 æg g-1 and from 0,69 to 2,21 æg g-1, in the modifier absence and in the presence of BaF2, respectively. The limit of detection (LOD) were 0,94 and 0,74 æg L-1, in the modifier absence and in the presence of BaF2, respectively. The characteristic mass were 17 pg V and 15,8 pg V, in the modifier absence and in the presence of BaF2, respectively. The relative standard deviation (r.s.d.) was _ 4,2 % in the modifier absence and _ 2,6% in the presence of BaF2. At the roots of the enriched garden parsley, the concentrations varied from 2,93 to 3,44 æg g-1 V and from 2,92 to 3,43 æg g-1 V, without and with modifier, respectively. The limit of detection (LOD) were 0,64 and 0,70 æg L-1, in the modifier absence and in the presence of BaF2, respectively. The relative standard deviation (r.s.d.) was _ 3,3 % and _ 2,3%, in the modifier absence and in the presence of BaF2, respectively. A paired t-test showed that results between all methods were in agreement at 95% confidence level. Two standard reference materials from the National Institute of Standards and Technology... / Mestre

Page generated in 0.043 seconds