• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 647
  • 11
  • 6
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 669
  • 669
  • 463
  • 459
  • 168
  • 146
  • 123
  • 123
  • 118
  • 86
  • 86
  • 84
  • 80
  • 70
  • 56
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
141

Contribuição ao protocolo de normatização de ensaios para a avaliação da sensibilidade de gotejadores à obstrução causada por partículas sólidas / Contribution to a standardized test protocol for assessing the sensitivity of drippers to clogging due to solid particles

Pereira, Diego José de Sousa 07 February 2019 (has links)
A obstrução dos emissores é apontada como o principal problema da irrigação por gotejamento, sendo a obstrução por agentes físicos a mais observada. No mercado, existem diversos modelos de emissores, sendo que a sensibilidade à obstrução varia conforme a qualidade da água e a geometria interna do emissor. Nesse contexto, o desenvolvimento de uma metodologia de avaliação da susceptibilidade de emissores à obstrução é importante para a identificação de modelos de emissores menos sensíveis à obstrução. A norma ISO/DTR 21540 (em desenvolvimento) especifica métodos de laboratório e de campo para a avaliação da sensibilidade de gotejadores à obstrução causada por partículas sólidas. O objetivo dessa pesquisa foi identificar limitações e propor aprimoramentos na etapa de ensaios de laboratório da ISO/DTR 21540, visando melhorar a repetitividade dos resultados e contribuir para a obtenção de uma metodologia mais robusta e confiável. Além disso, para a compreensão dos processos de obstrução por partículas sólidas, buscou-se analisar as principais causas e regiões de deposição de partículas ao longo dos labirintos dos emissores. Foram avaliados dois modelos de emissores (Taldrip 0,55 L h-1 e Drip-Tech 1,55 L h-1). O material utilizado como agente causador de obstrução foi um composto de partículas sólidas preparadas a partir de solo natural conforme requisitos da norma ISO 11277. O ensaio de obstrução consistiu de quatro fases, com duração de 40 horas cada, em uma combinação entre faixas granulométricas (0-75, 75-125; 125-212 e 212-500 μm) e concentração de partículas (125, 250, 375 e 500 mg L-1), com o aumento do risco de obstrução a cada fase. Essa pesquisa permitiu identificar limitações e enunciar recomendações para melhoria do protocolo de ensaios em discussão na ISO/DTR 21540. O acúmulo de partículas com dimensões relativamente grande (> 125 μm) foi a principal causa de obstrução, reforçando a probabilidade de que a granulometria de partículas é um fator dominante nos processos de obstrução quando se usa esse protocolo de ensaios. / Clogging of emitters is pointed out as the main problem of drip irrigation, being the clogging by physical agents the most observed. In the market, there are several models of emitters, and the sensitivity to the clogging varies according to the water quality and the internal geometry of the emitter. In this context, the development of a methodology that evaluates the susceptibility of emitters to clogging is important, once that it can identify less sensitive emitter models to clogging. The standard ISO / DTR 21540 (under development) specifies laboratory and field methods for assessing the sensitivity of drippers to clogging caused by solid particles. The aim of this research was to identify limitations and propose improvements in the ISO / DTR 21540 laboratory test stage, in order to improve the repeatability of the results and contribute to a more robust and reliable methodology. In addition, to understand the solid particle clogging processes, were analyzed the main causes and regions of particle deposition along the labyrinths of the emitters. Two emitter models (Taldrip 0.55 L h-1 and Drip-Tech 1.55 L h-1) were evaluated. The material used as clogging agent was solid particles compound prepared from natural soil according to the ISO 11277 requirements. The clogging test consisted of four stages, lasting 40 hours each, in a combination of granulometric range (0-75, 75-125, 125-212 and 212-500 μm) and particle concentration (125, 250, 375 and 500 mg L-1), with higher risk of clogging at each stage. This research allowed to identify limitations and enunciate recommendations for improvement of the test protocol under discussion in ISO / DTR 21540. The accumulation of particles with relatively large dimensions (> 125 μm) was the main cause of clogging, reinforcing the probability that the grain size particle is a dominant factor in the clogging processes when using this test protocol.
142

Influência da toxicidade da água e do sedimento dos rios São Joaquim e Ribeirão Claro na bacia do Corumbataí / Influence of water and sediment toxicity of the São Joaquim and Ribeirão Claro Rivers on the Corumbataí River Basin

Messias, Tâmara Guindo 27 August 2008 (has links)
A bacia do rio Corumbataí localizada na região central do estado de São Paulo, abrange parte dos municípios de Analândia, Corumbataí, Santa Gertrudes, Rio Claro, Itirapina, Ipeúna, Charqueada e Piracicaba, durante seu percurso os rios: Passa Cinco, Ribeirão Cabeça e Ribeirão Claro, considerados seus principais afluentes, influenciam significativamente nas características de suas águas. Os testes de toxicidade vêm sendo utilizados e reconhecidos mundialmente como uma ferramenta eficaz no biomonitoramento e na avaliação da qualidade das águas e dos sedimentos. Visando avaliar e entender o decréscimo da qualidade da água e do sedimento do rio Corumbataí, após a afluência das águas do Ribeirão Claro foram analisadas amostras em cinco pontos de coleta: dois no Ribeirão Claro, dois no rio Corumbataí e um no rio São Joaquim. Foram realizados testes ecotoxicológicos com Hydra attenuata, Pseudokirchneriella subcapitata, Chironomus xanthus, Lactuca sativa e Dapnhia magna, determinações físicas, químicas e biológicas para avaliação do IQA e quantificação dos elementos químicos: Be, Al, Na, Mg, Ca, K, V, Mn, Fe, Cr, Co, Ni, Cu, Zn, As, Se, Ag, Cd, Sb, Ba, Hg, Pb, Th, Tl, U por Espectrofotometria de massas com fonte de plasma induzido (ICP-MS). As coletas ocorreram trimestralmente de Abril de 2006 a Maio de 2007. Os resultados das quantificações dos elementos químicos foram comparados aos limites determinados pela Resolução CONAMA 357/05, e observados valores de Al, Fe, Hg e Pb, acima do recomendado. As análises físicas, químicas e biológicas mostraram que o oxigênio dissolvido (OD), fósforo total, nitrogênio amoniacal, demanda bioquímica de oxigênio (DBO5dias) e os coliformes fecais estão fora dos padrões recomendados. A avaliação do IQA aponta Classificação Ruim para todas as amostras do rio São Joaquim, para o Ribeirão Claro três Ruins, uma Boa e uma Imprópria, mostrando a importância destes afluentes para a piora das águas do rio Corumbataí. Todas as amostras de água e sedimento apresentaram toxicidade para pelo menos um dos organismos utilizados, principalmente para H. attenuata, P. subcapitata e C. xanthus. A sensibilidade da H. attenuata esteve diretamente relacionada à presença dos coliformes fecais, Cu, Ag, Ni e Zn, enquanto que a da P. subcapitata esteve relacionada à presença de Zn, Na, DBO e diminuição do OD, segundo as análises estatísticas de redundância (RDA) rodadas pelo R estatístico. Os elementos químicos Al e Fe estiveram presentes nas amostras de água e sedimento, acima do recomendado pelo CONAMA para rios de Classe 2, assim como o Mn, o qual teve sua concentração elevada pelas chuvas, enquanto que os elementos Be, V, Cr, Co, Ni, As, Cu, Cd, Sb, Ba, Pb, Zn e U estiveram abaixo ou próximo aos limites. O sedimento apresentou os elementos biodisponível na seguinte ordem decrescente: Mn > Zn > Ba > Pb > Cu > V > Cr > Co > Ni > As > U > Be > Ag > Cd > Se > Hg > Sb, quando retirado o Al e o Fe. Os rios São Joaquim e Ribeirão Claro influenciaram negativamente a qualidade da água do rio Corumbataí / The Corumbataí river basin located on Central region in São Paulo State is composed by part of Anâlandia, Corumbataí, Rio Claro, Itirapina, Ipeúna, Charqueada and Piracicaba municipality. The principals affluents rivers are Passa Cinco, Ribeirão Cabeça and Ribeirão Claro that have influence on water characteristics of Corumbataí river. The toxicity test has been recommended as an efficient tool for biomonitoring and evaluation of water and sediment quality. With the aim of evaluate and understand the decrease of water and sediment qualities of Corumbataí river five sampling sites were selected: two on Ribeirão Claro river, two on Corumbataí river and one on São Joaquim river. Ecotoxicity tests were performed with Hydra attenuata, Pseudokirchneriella subcapitata, Chironomus xanthus, Lactuca sativa and Dapnhia magna. For evaluation o IQA, were carried out physical, chemical and biology determinations as well chemical elements quantification by ICP-MS, such as: Be, Al, Na, Mg, Ca, K, V, Mn, Fe, Cr, Co, Ni, Cu, Zn, As, Se, Ag, Cd, Sb, Ba, Hg, Pb, Th, Tl and U. The water samples were collected every three mouth from April 2006 to May 2007. The chemical elements quantification results were compared with values standardized by CONAMA 357/05 Resolution. The Al, Fe, Hg e Pb concentration were over the ones recommended. The physical, chemical and biology assays showed that the dissolved oxygen, total phosphorus, ammonia nitrogen, biochemical oxygen demand and fecal coliforms were out of the standard recommendation. The IQA evaluation classified all water samples from São Joaquim River as Bad, the Ribeirão Claro three water samples were Bad, one Good and another Improper. So it showed the importance of these affluents on the decrease of Corumbatai river water quality. All the water and sediment samples showed toxicity at least for one organism tested, mainly for H. attenuata, P. subcapitata e C. xanthus. The H. attenuata sensity were directly affected by fecal coliforms, Cu, Ag, Ni and Zn, meanwhile the P. subcapitata were affect by Zn, Na, DBO and lowest level of OD, as obtained by redundancy analysis (RDA) on R statistics program. The chemical elements Al and Fe were present on water and sediment sample, over the recommend concentration of CONAMA 357/05 Resolution for rivers of Class 2 as the same for the Mn, which had high concentration after rain. On the other hand the elements Be, V, Cr, Co, Ni, As, Cu, Cd, Sb, Ba, Pb, Zn and U were below or near the limits. The sediment showed the chemical elements in this order: Mn > Zn > Ba > Pb > Cu > V > Cr > Co > Ni > As > U > Be > Ag > Cd > Se > Hg > Sb, when the Al and Fe where not considered. The São Joaquim and Ribeirão Claro rivers had a negative influence on Corumbataí river water quality
143

Avaliação ecotoxicológica da água e sedimento de tributários do reservatório de Barra Bonita (Médio Tietê Superior - SP) / Ecotoxicological assessment of water and sediment from tributaries of Barra Bonita reservoir (middle Tietê Superior - SP)

Costa, Juliana Berninger da 02 July 2001 (has links)
Neste estudo, avaliou-se a qualidade da água e sedimento dos principais tributários do reservatório de Barra Bonita (médio Tietê Superior - SP), analisando 14 estações amostrais em um período anual, através de estudos limnológicos e ensaios de toxicidade crônica (utilizando os cladocera planctônicos Ceriodaphnia dubia e Ceriodaphnia silvestrii como organismos-teste). Os resultados das análises físicas e químicas da água e sedimento demostraram a existência de locais altamente impactados, como os rios Tietê, Capivari, Lavapés e Piracicaba, receptores primário de efluentes domésticos e industriais dos municípios localizados na região. Os bioensaios com C. silvestrii e C. dubia confirmaram o alto grau de degradação destes ambientes, verificando-se indícios de toxicidade crônica em amostras de água pertencentes aos rios Capivari (estação 1), Tietê (estação 2), Piracicaba (estação 4) e Lavapés (estação 11) e toxicidade crônica em amostras de água pertencentes aos rios Tietê e Piracicaba, em especial, por apresentarem alta vazão e baixo tempo de residência da água, representam a principal contribuição de contaminantes para o reservatório de Barra Bonita, uma vez que grande parte dos nutrientes, metais e material em suspensão observados nestas áreas é transportado até a área de influência da represa, podendo causar eutrofização e assoreamento na região. Também foram identificadas áreas com baixo grau de impacto antrófico, como os rios dos Peixe, Capivara e Araquá (com valores de nutrientes e metais que chegam a ser seis vezes inferiores aos obtidos nos rios Capivari e Tietê), que contribuem, em menor escala, para uma relativa diluição dos contaminantes transportados até o reservatório. / In this study, water and sediment quality of the most important tributary of Barra Bonita\'s reservoir (Tiete Median Superior - SP) was assessed using limnological analysis and chronic bioassays (with the planktonic cladocerans Ceriodaphnia dubia and Ceriodaphnia silvestrii) throughout 14 stations in a one-year period. This approach showed greatly impacted sites, as are the Tiete, Capivari, Lavapes and Piracicaba rivers, all of them receptors of domestic and industrial wastewater from the cities of the region. The bioassays with C. silvestrii and C. dubia confirmed these results. It was identified that on Capivari (site 1), Tiete (site 2), Piracicaba (site 4) and Lavapés (site 11) water samples, there were traces of chronic toxicity, and it was verified that chronic toxicity on Tiete (site 9), Piracicaba (site 7) and Capivari (site 1) sediment samples existed as well. The Tiete and Piracicaba rivers , with high levels of flow and low time of water residence, represent the principal contribution of contaminants to Barra Bonita\'s Reservoir, due to the transport of nutrients, metals and suspended materials f rom these environments to the Reservoir\'s area of influence, causing eutrophication. Areas with low levels of human impact, like Peixe, Capivara and Araquá rivers (with values of nutrients and metals six times lower than those of the Capivari and Tiete rivers) were also identified. These low impact rivers contribute less contaminants , through a relative dilution, transported to the reservoir.
144

Estudo experimental de biomanipulação: análise dos impactos ambientais de duas espécies de predadores no controle de Tilápia, no lago Paranoá (Brasília - DF) / Experimental study of biomanipulation: analysis of environmental impact of two species of predators in the control of Tilápia, in Paranoá lake (Brasília, DF)

Ribeiro Filho, Rinaldo Antonio 26 July 2002 (has links)
O gerenciamento dos estoques pesqueiros, um dos instrumentos da biomanipulação, deve ter início com a classificação das espécies existentes e sua diversidade, a estrutura da rede alimentar e as relações reguladoras, como a relação predador-presa. O lago Paranoá (Brasília - DF) é um reservatório urbano que sofre pressões antrópicas devido a seus usos múltiplos. Após a construção enchimento, sucessivas introduções de espécies ictíicas exóticas causaram um desequilíbrio que, associado às pressões descritas acima, geraram uma aceleração no processo de eutrofização deste ambiente. Desta forma, os objetivos deste trabalho foram: avaliar os impactos ambientais da introdução das espécies predadoras sobre a cadeia trófica e a qualidade da água do reservatório; determinar a eficiência das diferentes espécies de predadores no controle das presas nas áreas marginais da represa, discutindo possíveis estratégias de manejo pesqueiro baseadas na estocagem de peixes predadores. Para tanto foram construídos 10 limnocurrais com lonas impermeáveis numa baía localizada no ETE-Norte (Estação de tratamento de esgotos - Norte). Em seu interior, após a retirada de todos os peixes, foram estocadas por um período de 28 dias, duas espécies de predadores (Cichla ocellaris e Pseudoplatytoma fasciatum) e uma comunidade simplificada de presas (Tilapia rendalli e Oreochromis niloticus), acima da capacidade do suporte do sistema, definida em 4 classes de tamanho. As biomassas de estocagem foram determinadas a partir da aplicação de retenona em uma área com dimensões conhecidas, e extrapoladas para as áreas dos limnocurrais. As variáveis físicas e químicos da água foram acompanhados semanalmente durante o experimento. Não houve diferenças significativas entre os tratamentos, em relação às variáveis limnológicas. Quanto ao controle das presas, o tucunaré mostrou-se um predador eficiente em relação às classes de tamanhos menores ) (2 - 6,9 cm e 7 - 12,9 cm), fato não observado para o tratamento com surubim. De acordo com os resultados obtidos, não foi comprovada a hipótese de cascata trófica devido à complexidade das interações entre os organismos em ambientes tropicais. / The managing of the fish stocks, one of the tools of the biomanipulation, must begin with the classification of the present species and their diversity, of the structure of the food web and of the regulation relations (as the relation predator-prey).The Paranoá Lake (Brasília, DF) is an urban reservoir that suffers human pressures as a result of its multiple uses. After its construction and filling, the successive introduction of many fish exotic species resulted in an unbalance that, associated with the pressures described above, generated an acceleration in the eutrophication process of the ambient. In this way, the objectives of this work were: evaluate the environmental impacts from the introduction of the species predators in food web and quality from the reservoir\'s water; decide the efficiency of the species of predators in the prey\'s control in the marginal areas from dam, discussing possible fishing strategies of management based in the Stocking of fish predators. Them, 10 limnocorrals were built with waterproof canvases in a bay located in ETE-NORTE (sewers handling Station - North). In its interior, after retreat of all fishes, by a period of 28 days, two species of predators were stocked (Cichla ocellaris and Pseudoplatystoma coruscans), and a community simplified of prey (Tilapia rendalli and Oreochromis niloticus), above from the capacity of the system, defined in 4 classes of size. The biomasses of stocking were determined from application of rotenona in an area with known dimensions, and overstepped for the areas of the limnocorrals. The physical-chemists parameters from the water were accompanied weekly during the experiment. It had no significant differences between the handlings, regarding the variables limnological. As regards the control of prey, C. ocellaris showed itself an efficient predator regarding the smallest classes of sizes (2 - 6,9 cm and 7 - 12,9 cm), fact do not observe for the handling with P. coruscans. Agreement with the results obtained, was not verified to hypothesis of trophic cascade due to the complexity of the interactions between the agencies in tropical environments.
145

Desenvolvimento e avaliação de um sistema de filtragem com reversão de fluxo de alta frequência / Development and assessment of filtration in irrigation system with high frequency reversal flow

Pinto, Marinaldo Ferreira 18 June 2013 (has links)
A obstrução de emissores tem sido um entrave para a microirrigação. Porém, tem-se notado poucos estudos relativos ao desenvolvimento de equipamentos que auxiliam na prevenção da obstrução de emissores nos últimos anos. Os estudos realizados nesta linha estão geralmente ligados à caracterização dos sistemas em uso. O objetivo deste trabalho foi desenvolver um sistema de filtragem com reversão automática de fluxo, de alta frequência. O sistema foi concebido para operar com água de baixa qualidade, com inversão de fluxo e limpezas automáticas e com volume mínimo de água para realização das limpezas. As decisões do controlador do sistema de filtragem têm como base a perda de carga, obtida por meio de transdutores de pressão instalados na entrada e na saída do sistema. O protótipo final é composto, basicamente, por três filtros de tela e onze válvulas solenoides controladas eletronicamente. Determinou-se a curva de perda de carga em função da vazão, a eficiência de retenção e o volume mínimo de água para limpeza dos filtros. A eficiência de retenção de partículas foi determinada em delineamento experimental inteiramente aleatorizado em esquema fatorial, sendo testados três fatores: tempo de reversão (15 e 30 s); incremento da perda de carga (25 e 50%) e concentração de sólidos (500 e 1000 mg L-1). A eficiência de retenção de sólidos totais foi de 71,7 e 78,3% para as concentrações de 500 e 1000 mg L-1, respectivamente, tendo apresentado diferença significativa a 1% de probabilidade. Entretanto, a eficiência retenção de sólidos maiores que 50 ?m (Ed > 50) foi de 98,6 ± 0,7%, não sendo significante para nenhum dos tratamentos ao nível de significância de 1%. O volume médio de água despendido durante as limpezas foi de 5,39 L por limpeza, que representou um volume de água de limpeza por volume de água filtrada de 8,0 e 12,6 L m-3, para as concentrações de 500 e 1000 mg L-1, respectivamente. Os valores de eficiência energética do sistema de filtragem variaram de 80 a 90% para a vazão de 2 m3 h-1 com pressão de entrada entre 15 a 40 mca. As limpezas do sistema de filtragem não foram totalmente eficazes na retomada da perda de carga, com tendência de aumento com o tempo. A inversão de fluxo com frequências de 11,11 e 22,22 mHz influenciou na evolução da perda de carga do sistema de filtragem, tornando-a mais lenta que a evolução para o sistema funcionando sem inversão de fluxo. Considerou-se que o sistema de filtragem desenvolvido apresentou potencial para filtragem da água de irrigação com baixa qualidade, porém necessita de manutenções periódicas para limpeza do elemento filtrante. A perda de carga admissível do sistema de filtragem deve ser o valor mais restritivo entre o critério de desempenho de retenção de partículas e o de variação de vazão do sistema de irrigação. / Emitters clogging have been a barrier to trickle irrigation. Just a few studies have been performed concerning equipments which assist in preventing emitters clogging in recent years, especially regarding to development equipment. Studies carried out on this issue are usually linked to the characterization of systems in use. The aim of this study was to develop a filtering system with automatic flow reversal of high frequency. The system is designed to operate with low quality water, with reverse flow and automatic cleanings and with minimum volume of water to perform the cleaning. Decisions by the controller of the filtration system are based on head loss, obtained by pressure transducers installed at the upstream and downstream of the system. The final prototype consists of three screen filters and eleven electronically controlled solenoid valves. The curve of head loss was determined as a function of water flow, retention efficiency and minimum volume of water required for cleaning the filters. The efficiency in particle retention was determined following a completely randomized experimental design in a factorial scheme in which three factors were tested: reversal time (15 and 30 s) increase in head loss (25 and 50%) and solids concentration (500 and 1000 mg L-1). The total solids retention efficiency was 71.7 and 78.3% for concentrations of 500 and 1000 mg L-1, respectively, presenting a significant difference at 1%. However, when analyzing the retention efficiency of solids larger than 50 ?m (Ed> 50), none of the treatments was significant at 1%, whose efficiency was 98.6 ± 0.7%. The mean volume of water expended during the cleaning was 5.39 L. It represented a volume of water for cleaning per volume of filtered water from 8.0 and 12.6 L m-3, to concentrations of 500 and 1000 mg L-1, respectively. The energy efficiency values of filtering system ranged from 80 to 90% considering flow rate of 2 m3 h-1 and inlet pressure ranging from 15 to 40 mca. The filtering system cleaning was not totally effective in reestablishing the head loss, with an upward trend over time. The reverse flow with frequency of 11.11 and 22.22 mHz influenced the head loss evolution of the filtration system, making it slower than the trend for the system running without flow reversal. The developed filtration system has potential for filtering low quality irrigation water, but it requires periodic maintenance to clean the filter element. The allowable head loss of the filter system should be the most restrictive value between the criterion of particle retention performance and the flow variation of the irrigation system because of the increase in head loss in the filters.
146

Interconectividade de aquíferos e os efeitos da drenagem ácida de mina na qualidade das águas da Bacia carbonífera de Santa Catarina (SC)

Hoelzel, Marlon Colombo January 2018 (has links)
A mineração do carvão no sul de Santa Catarina se desenvolve há mais de um século e a falta de gerenciamento ambiental nos empreendimentos mineiros causou significativas alterações de qualidade nos recursos hídricos superficiais e subterrâneos da Bacia Hidrográfica do Araranguá. Além da alteração na qualidade das águas, fenômenos de abatimento de minas subterrâneas ocasionaram o fraturamento das camadas sobrejacentes, e permitiram a ampliação dos processos de circulação dos sistemas aquíferos com corpos hídricos superficiais. Como objetivo de melhorar o entendimento sobre os impactos na qualidade das águas e nas condições de fluxo subterrâneo, foram analisadas amostras das águas de 9 poços do Sistema Aquífero Rio Bonito, 4 poços do Sistema Aquífero de Leques Aluviais e 6 amostras de águas superficiais das mesmas microbacias onde estão instalados os poços. As análises hidroquímicas indicam uma predominância de águas bicarbonatadas cálcicas e sódicas, que quando em contato com a drenagem ácida de mina são transformadas em águas sulfatadas. Os valores isotópicos de δ2H e δ18O das amostras evidencia semelhança com a composição isotópica das águas meteóricas, contribuindo com a hipótese da forte interação da água subterrânea com as águas freáticas e superficiais, que ocorre devido à tectônica rúptil que afeta as litologias gonduânicas, e é intensificada pela presença das minas de subsolo. / Coal mining in southern Santa Catarina has been developed over a century and the absence of environmental management in mining projects caused significant quality changes in the surface and underground waters of the Araranguá Basin. In addition to the change in water quality, collapses have occurred in underground mines which caused the fracturing of overlying layers and allowed the expansion of aquifer systems and its integration with surface waters circulation processes. In order to better understand the impacts on water quality and groundwater flow conditions, samples of 9 wells from Rio Bonito Aquifer System, 4 wells from Alluvial Fan Aquifer System and 6 from surface waters of the same catchments were analyzed. Hydrochemical analysis indicates a predominance of calcium and sodium bicarbonate waters which when in contact with acid mine drainage are transformed into sulfated waters. The isotopic values δ2H and δ18O shows similarity to isotopic composition of meteoric waters, contributing to the hypothesis of the strong interaction between groundwater, waters from water table and surface waters, which occurs due to the ruptured tectonics affecting gondwana lithologies and it is intensified by the presence of underground mines.
147

Quantificação e avaliação do coeficiente de dispersão longitudinal em cursos d\'água / Quantification and evaluation of longitudinal dispersion coefficient in streams

Vanessa Vaz de Oliveira 21 October 2013 (has links)
Um parâmetro físico essencial na modelagem matemática de qualidade de água visando a análise do impacto causado pelo lançamento de efluentes nos corpos d\'água superficiais é o coeficiente de dispersão longitudinal (DL). Portanto, a devida quantificação desse parâmetro é de grande importância para garantir a confiabilidade dos resultados de um modelo matemático de qualidade de água. Sendo assim, o presente trabalho propôs a quantificação de tal parâmetro. Para isso foram efetuados ensaios de campo de estímulo-resposta com traçador salino (cloreto de sódio) em dois cursos d\'água de pequeno porte localizados no município de Uberaba - MG. Após a realização dos ensaios de campo foram utilizados métodos diretos para a quantificação do parâmetro a partir dos dados experimentais. Os valores de DL mais confiáveis derivaram do método da convolução (routing procedure), variando de 0,70 a 10,44 m2/s. Também foi desenvolvido um modelo matemático de previsão do coeficiente de dispersão longitudinal a partir dos resultados experimentais com base em análise dimensional e a técnica de regressão linear múltipla. O r2 da equação gerada foi de 0,87, o que sugere que esta equação é adequada para a estimativa do coeficiente de dispersão longitudinal para os cursos d\'água estudados. Foi efetuada também a validação da aplicabilidade do modelo matemático desenvolvido a outras condições de campo diferentes daquelas utilizadas em sua dedução, com base em resultados experimentais obtido por outros autores. Por fim foi obtida, para os trechos dos cursos d\'água estudados, os coeficientes de dispersão longitudinal pelas equações empíricas e semi-empíricas de previsão mais conhecidas na literatura, comparando-se o desempenho de tais equações com a equação desenvolvida no trabalho através de análise estatística. A equação produzida no presente trabalho gerou melhores estimativas do coeficiente de dispersão longitudinal para os cursos d\'água estudados do que as equações utilizadas para comparação. / An essential parameter in the mathematical modeling of water quality in order to analyze the impact caused by the release of effluents into surface water bodies is the longitudinal dispersion coefficient (DL) . Therefore, proper quantification of this parameter is of great importance to ensure the reliability of the results of a mathematical model of water quality. Thus, this paper proposed to quantify this parameter. For this, field tests were conducted with stimulus-response tracer salt (sodium chloride) in two small streams located in Uberaba - MG. After completion of the field tests, direct methods to quantify the parameter from experimental data were used. The most reliable DL values derived from the routing procedure method, with valuer between 0.70 to 10.44 m2/s. Also we developed a mathematical model to predict the longitudinal dispersion coefficient from the experimental results based on dimensional analysis and multiple linear regression technique. The equation r2 generated was 0.87, suggesting that this equation is suitable for the estimation of longitudinal dispersion in the studied streams. We also performed the validation of the applicability of the developed mathematical model to other field conditions different from those of your deduction, based on experimental results obtained by other authors. Finally we obtained in the literature for the sections of the studied streams, the longitudinal dispersion coefficients by the best known empirical and semiempirical equations, comparing the performance of such equations with the equation developed in this work through statistical analysis. The equation produced in this study gave better predictions of the longitudinal dispersion coefficient for the studied streams than the equations used for comparison.
148

Metodologia para a tomada de decisão sobre a utilização de água subterrânea no abastecimento público no entorno de áreas urbanas industrializadas / Methodology for decision making on the use of groundwater for public supply in the vicinity of industrialized urban areas.

Paulo Roberto Penalva dos Santos 17 May 2016 (has links)
Grandes centros urbanos, principalmente em regiões metropolitanas que abrigam polos industriais e petroquímicos, apresentam uma maior frequência de riscos de contaminação das águas subterrâneas por compostos orgânicos, metais pesados e também por compostos orgânicos emergentes (EOCs), como fármacos, produtos de higiene pessoal (PHPs), hormônios, vitaminas e outros interferentes endócrinos. No Brasil, vários problemas de águas subterrâneas contaminadas vêm sendo registrados, limitando, muitas vezes, a utilização desses mananciais como fonte de abastecimento humano, em decorrência da presença de compostos de origem industrial e petroquímica, além de outras substâncias orgânicas e inorgânicas, ambas associadas às atividades antrópicas, que apresentam graus diversos de risco à saúde humana. Neste estudo, de teor exploratório, documental e interdisciplinar, utilizou-se a região de influência do Polo Industrial de Camaçari (PIC), localizado na região metropolitana de Salvador, como área de estudo. Foram feitas avaliações de dados hidrogeológicos e também de resultados analíticos dos parâmetros monitorados no período de 2000 a 2011 obtidos dos bancos de dados de várias empresas, especialmente da CETREL (Empresa de Proteção Ambiental), da CERB (Companhia de Engenharia Ambiental da Bahia) e de outras empresas, como de consultoria e também perfuradoras. Deu-se ênfase naqueles legislados para potabilidade da água através da Portaria 2914/2011 do Ministério da Saúde. O objetivo do trabalho foi o desenvolvimento de uma metodologia para a tomada de decisão quanto ao uso ou não de águas subterrâneas para o abastecimento público em regiões com impacto industrial. Esta metodologia consistiu de várias etapas: avaliação e associação de atributos do modelo conceitual hidrogeológico da área; desenvolvimento de um índice de qualidade de água subterrânea (IQASUB/AUI Índice de Qualidade de Água Subterrânea para Áreas Urbanas Industrializadas), incluindo os contaminantes industriais considerados carcinogênico para os seres humanos pela IARC (International Agency for Research on Cancer, órgão da Organização Mundial da Saúde WHO), e análise comparativa entre o índice de qualidade IQA-CCME (CCME, 2001a) e o novo índice de qualidade construído, o IQASUB/AUI. Os resultados da comparação entre os dois índices associados aos atributos do modelo conceitual hidrogeológico da região demonstraram a adequação da proposta metodológica para a decisão expedita sobre o uso de água subterrânea da região de estudo. A proposta metodológica pode ter suas contribuições estendidas para outras regiões metropolitanas brasileiras. Espera-se também que possa contribuir para a adoção de estratégias que possibilitem um melhor aproveitamento das águas subterrâneas, minimizando os riscos à saúde pública e ao ambiente. Enfim, que possa aprimorar a sua governança. / Large urban centers, especially in metropolitan areas and where industrial and petrochemical complexes are located, have an increased frequency of risks of contamination of groundwater by organic compounds, heavy metals and also by emerging organic compounds (EOCs), as pharmaceuticals, personal care products (PCPs), hormones, vitamins and other endocrine disruptors. In Brazil, several problems of contaminated groundwater have been registered often limiting the use of these resources for human supply, due to the presence of compounds from industry in general petrochemicals products and other organic and inorganic substances, both linked to human activities, with different degrees of risk to human health. In this study, with exploratory, documentary and interdisciplinary scope, the study area was the area of influence of the Camaçari Industrial Complex, located in Salvador BA metropolitan. Were evaluated hydrogeological data also analytical results from the chemical parameters monitoring from 2000 to 2011. Special emphasis went to those legislated for human consumption with potability requiremensts regulated by Resolution 2914/2011 from the Ministry of Health. The data were of various companies, especially from CETREL (Environmental Protection Company), CERB (Environmental Engineering Company of Bahia) and other companies, such those dedicated to consulting and drilling. The objective of this work was to propose a methodology for decision making regarding the management of groundwater used for public water supply in the study. This methodology envolves the evaluation and association of attributes to the hydrogeological conceptual model for the development of a groundwater quality index. The IQASUB/AUI - Groundwater Quality Index for Urban Areas Industrialized includes mainly, industrial contaminants with potential, as carcinogenic for humans or already confirmed by IARC (International Agency for Research on Cancer, an agency of the World Health Organization). The methodology used a comparative analysi between of the water quality index IQA-CCME (CCME, 2001a) and the proposed, quality index IQASUB/AUI. The comparison of these two indices associated with the attributes of the region hydrogeological conceptual model, endorsed the appropriateness of this proposal for the expeditious management of the quality of groundwater study area. The methodology can certainly contribute and be extrapolated to other Brazilian metropolitan areas. Also the results of this study can probably with strategies that well allow a better use the groundwater, through an integrated approach for the water use, an instrument to minimize the risks to public health and to environment, and improving its governance.
149

Avaliação da qualidade da água do ribeirão Taquaruçu durante o processo de implantação do Projeto Produtor de Águas

Condo, César Ricardo Palomino 24 June 2016 (has links)
A bacia do ribeirão Taquaruçu, localizada no município de Palmas-Tocantins, vem sofrendo nestes últimos anos acentuada redução de vazão e, ao mesmo tempo, perda de qualidade de suas águas. Com o objetivo de minimizar estas deficiências, a bacia entrou em um processo de revitalização por meio da implantação do Programa Produtor de Águas, cujo princípio seria a recompensa financeira através de pagamentos por serviços ambientais. Devido à importância de um diagnóstico na qualidade da água dos ribeirões no programa, foram definidas cinco estações amostrais para realização de análises mensais de variáveis físico-químicas e bacteriológicas durante o ano de 2014. A análise de componentes principais foi aplicada e mostrou que durante o período chuvoso, principalmente no mês de março, as cinco estações amostrais apresentaram acentuada correlação entre a demanda bioquímica de oxigênio e oxigênio dissolvido. Já para o fósforo, turbidez, sólidos suspensos totais e cor verdadeira, foram registradas elevadas concentrações no inicio e final do período chuvoso, em quase todos os pontos de coleta. Depois de analisado o cenário, os resultados permitiram concluir que a qualidade da água da bacia apresentou-se sinérgica e susceptível às variações hidrológicas, principalmente na região do Baixo Taquaruçu Grande, e que a realidade socioambiental da região foi determinante para a perda da qualidade da água registrada durante o período chuvoso. / The basin of the Taquaruçu creek, located in Palmas-Tocantins, has been suffering, in recent years, a sharp reduction of flow and at the same time, loss of water quality. In order to minimize these deficiencies, the basin entered a revitalization process through the implementation of the Water Producer Program, whose principle would be a financial reward through payments for environmental services. Due to the importance of a diagnosis in the water quality of creeks in the program five sampling stations were defined to perform monthly analysis of physicochemical and biological variables during the year 2014. The principal component analysis was applied and showed that during the rainy season, mainly in March, the five sampling stations presented a sharp correlation between the biochemical oxygen demand and dissolved oxygen. As for phosphorus, turbidity, total suspended solids and true color, high concentrations were recorded at the beginning and end of the rainy season, in almost every collection point. After examining the scenario, the results showed that the water quality of the basin has performed synergistic and susceptible to hydrological variations, mainly in the region of Lower Taquaruçu Grande, and the environmental reality of the region was crucial to the loss of water quality logged during the rainy season.
150

QUALIDADE DA ÁGUA DA NASCENTE JARDIM DA LUZ DO CÓRREGO BARREIRO EM GOIÂNIA/GO

Lima, Cleide Moco 25 June 2009 (has links)
Made available in DSpace on 2016-08-10T10:44:19Z (GMT). No. of bitstreams: 1 CLEIDE MOCO LIMA.pdf: 1281674 bytes, checksum: a18776358c4f0b8fd600ceb0770b47f2 (MD5) Previous issue date: 2009-06-25 / Stream Barreiro in Goiânia-GO is a Meia Ponte s tributary. It has approximately 8 km long and has 10 sources distributed in six neighborhoods. Currently, it has been shown that these sources are suffering more negative interventions to ecosystems due the growth of city and raising the level of pollution. In this research were studied the sources, quality of water and environmental impacts. Six sources are completely dry. One is located at Oscar Niemeyer Culture Center. Two are located near GO- 020. The main source is located in private property in Jardim da Luz. Three points were designed to collect. Water quality was analyzed by Standart Methods. Point 1 was outburst in the water, the middle section 2 and section 3 of the dam at the outlet of water to the bed of the stream. It was observed that water in point 1 is great quality, according to the parameters analyzed. However, the other two points of collection showed changes, mainly in conductivity, turbidity, alkalinity, hardness, OD, DBO e coliforms. These points the water is dammed and a large variety of aquatic animals. On site there is no riparian vegetation and the environment is completely anthropogenic disturbance. / O córrego Barreiro em Goiânia-GO é um afluente do rio Meia Ponte, apresenta aproximadamente 8 km de extensão e possui 10 nascentes distribuídas em seis bairros residenciais. Atualmente, tem sido evidenciado que estas nascentes vêm sofrendo várias intervenções negativas para os ecossistemas, devido ao crescimento da cidade e elevação do nível da poluição. Os objetivos desta pesquisa foram avaliar as nascentes do córrego Barreiro, determinar a qualidade da água da nascente localizada no bairro Jardim da Luz e a água da mesma a qual é usada para criação de peixes, em termos físico-químicos e microbiológicos. Os métodos de análises foram segundo Standard Methods. Foram definidos três pontos de coleta, sendo o ponto 1 no afloramento da água, o ponto 2 no meio da represa e o ponto 3 na saída da água para o leito do córrego. A qualidade da água foi avaliada por medidas de temperatura, condutividade elétrica, cor, pH, turbidez, alcalinidade total, dureza, OD, DBO, STD, STS, coliformes totais e termotolerantes. As coletas foram realizadas no período seco. Observou-se que seis nascentes do córrego encontram-se completamente secas. Uma está localizada no centro Cultural Oscar Niemeyer e duas se encontram nas proximidades da rodovia GO- 020. A nascente Jardim da Luz é a de maior vazão e se encontra dentro de uma propriedade particular, a qual foi objeto de estudo. De modo geral no ponto 1, a água se encontra em ótima qualidade, segundo os parâmetros analisados, ou seja e límpida, inodora e com ausência de coliformes fecais. No entanto, nos outros dois pontos de coleta, onde existe a criação de peixes, a água apresentou alterações nos parâmetros físico-químicos, na condutividade, turbidez, alcalinidade, dureza, OD, DBO e coliformes. Nestes pontos a água está represada e existe uma grande variedade de animais aquáticos. No local não existe mata ciliar e a nascente está completamente antropizada. Todas as nascentes do córrego não estão protegidas e não houve respeito à Legislação

Page generated in 0.6117 seconds