• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 647
  • 11
  • 6
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 669
  • 669
  • 463
  • 459
  • 168
  • 146
  • 123
  • 123
  • 118
  • 86
  • 86
  • 84
  • 80
  • 70
  • 56
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
281

Escalas espaciais e uso de indicadores bentônicos na avaliação da qualidade ambiental em um reservatório tropical

Farias, Rafaela Lima de 24 February 2014 (has links)
Made available in DSpace on 2015-09-25T12:22:20Z (GMT). No. of bitstreams: 1 PDF - Rafaela Lima de Farias.pdf: 1700848 bytes, checksum: 23fc477c9cd5ebd0a7e301c228cbba0e (MD5) Previous issue date: 2014-02-24 / Consider the various spatial scales to characterize ecological conditions of aquatic ecosystems is an important approach in the evaluation of environmental quality in watersheds. This study aimed to evaluate the environmental quality of a reservoir regarding levels of disturbance at different spatial scales besides to evaluate the influence of disturbances on the benthic macroinvertebrate community bioindicator of water quality. Data collection was performed in 40 equidistant sampling stations in the coastal area of the reservoir during the dry season of 2012. At each location aspects of use and occupation, physical characterization of habitats, physical and chemical parameters of the water column and sediment were evaluated. Multivariate analyzes (Cluster and PERMANOVA) were used to evaluate the sites sampled for levels of disturbances in macro (land use surrounding), meso (physical habitat metrics) and microescalas (limnological parameters). To define quantitatively the levels of disturbance the indices of Local Disturbance (IDL), Regional Disturbance (IDR) and the Integrated Disturbance (IDI) were used. The estimate of land use around the reservoir characterized the areas with high, medium and low degrees of disturbance. The metrics of physical habitats allowed the classification of sampling stations in just two groups: high and medium disturbances. As the limnological parameters (water and sediment) and biological did not vary in the coastal area of the reservoir, it was not possible to classify into groups of disturbance based on these data. The values of the indices of Disturbance (IDL, IDI and IDR) indicated a strong gradient of disturbance in the reservoir. Environmental assessment at different scales of observations allowed the classification of sampling sites regarding levels of disturbances in the two approaches (macro/meso scales and indices of disturbance). However, the benthic community from the perspective of bioindicator did not respond significantly to this classification. Future studies should consider the use of different scales of observation and biological metrics bioindicators as tools for environmental assessments of reservoirs in order to validate methodologies and propose effective measures for maintaining these systems. / Considerar as várias escalas espaciais na caracterização de condições ecológicas de ecossistemas aquáticos é uma abordagem importante na avaliação de qualidade ambiental em bacias hidrográficas. Este estudo teve por objetivo avaliar a qualidade ambiental de um reservatório quanto aos níveis de distúrbios em diferentes escalas espaciais, além de avaliar a influência dos distúrbios na comunidade de macroinvertebrados bentônicos bioindicadora de qualidade de água. A coleta de dados foi realizada em 40 estações amostrais equidistantes ao longo da região litorânea do reservatório, no período seco de 2012. Em cada local foram avaliados aspectos de uso e ocupação do solo, caracterização física de habitats, parâmetros físicos e químicos de qualidade de água na coluna d água e sedimento. Análises multivariadas (Cluster e PERMANOVA) foram utilizadas para avaliar os sítios amostrados quanto aos níveis de distúrbios em macro (uso do solo no entorno), meso (métricas de habitats físicos) e microescalas (parâmetros limnológicos). Para definir quantitativamente os níveis de distúrbios foram utilizados os índices de Distúrbio Regional (IDR), de Distúrbio Local (IDL) e o Integrado de Distúrbio (IDI). A estimativa dos usos do solo no entorno do reservatório caracterizou áreas com alto, médio e baixo graus de distúrbios. As métricas de habitats físicos permitiram a classificação das estações amostrais em apenas dois grupos: alto e médio distúrbios. Como os parâmetros limnológicos (água e sedimento) e biológicos não variaram na região litorânea do reservatório, não foi possível a classificação em grupos de distúrbios com base nesses dados. Os valores dos Índices de Distúrbios (IDR, IDL e IDI) indicaram um forte gradiente de perturbação no reservatório. Contudo, as métricas biológicas não mostraram relação com este gradiente. A avaliação ambiental em diferentes escalas de observações permitiu a classificação dos locais de amostragem quanto aos níveis de distúrbios nas duas abordagens (macro/meso escalas e índices de distúrbios). Porém, a comunidade bentônica sob a perspectiva de bioindicadora não respondeu de forma significativa a essa classificação. Futuros estudos devem considerar a utilização de diferentes escalas de observação e métricas biológicas bioindicadoras como ferramentas em avaliações ambientais de reservatórios, no intuito de validar metodologias eficazes e propor medidas de conservação desses sistemas.
282

Avaliação da qualidade da água  da sub-bacia  do Ribeirão Taquaruçu Grande e da área de sua influência no reservatório da usina hidroelétrica Luis Eduardo Magalhães, TO / Water quality evaluation of the Taquaruçu Grande sub-basin and its interfrence area in the reservoir of the Luis Eduardo Magalhães Hydroelectric Power Station TO, Brazil

Anelise Kappes Marques 23 February 2011 (has links)
O presente trabalho objetivou verificar a contribuição física, química e biológica da sub-bacia do ribeirão Taquaruçu Grande para o reservatório da Usina Hidroelétrica Luis Eduardo Magalhães, no médio Tocantins, TO. Realizaram-se coletas trimestrais de amostras de água superficial (água bruta), nos períodos de seca e chuva, de janeiro de 2007 a outubro de 2008, em oito pontos localizados na sub-bacia e no reservatório. Variáveis limnológicas foram coletadas e avaliadas de acordo com CETESB (2006) e APHA (2005), assim como os metais e elementos-traço analisados por espectrometria de emissão atômica com plasma de argônio induzido (ICP-OES) e por espectrometria de absorção atômica (AAS) com forno de grafita ou gerador de hidretos (Cotrim, 2006). Amostras biológicas da comunidade fitoplanctônica foram coletadas com rede de plâncton de 20 m, fixadas em solução Transeu na proporção de 1:1 para as análises qualitativas e em lugol acético para as análises quantitativas realizadas atreves de microscópio Olympus BX41. Condutividade elétrica, temperatura da água, sólidos totais dissolvidos, fósforo e pH apresentaram maiores concentrações no pontos lênticos do que na sub-bacia, parâmetros mais elevados no período chuvoso, fato atribuído ao aporte de material alóctone carreado pelas chuvas ao reservatório. Nitrato e sólidos fixos apresentaram maiores concentrações no reservatório na estiagem. As condições de eutrofia tornaram-se mais intensas com o avançar da seca e podem ser conseqüência dos processos de decomposição da matéria orgânica, que libera compostos nitrogenados. A maior concentração de sólidos fixos na estiagem provavelmente está associada à baixa profundidade dos pontos o que facilita a ressuspensão dos sedimentos pela ação dos ventos e do hidrodinamismo local. Ba, Na, Si, K, Al, Mn, Zn, Li, Mg, P, Ca, Fe e Ag estiveram presentes em todos os pontos na maioria do período amostral. As amostragens no mês de outubro de 2007 apresentaram elevadas concentrações de B, Al, Cr, Ni, Cu, Zn, Mo, P, Co, e Ag principalmente nos pontos amostrais da sub-bacia, associados á baixa profundidade dos córregos, que apresentaram águas rasas neste período o que facilitou o intemperismo. Al, Ag, Be, Co, Cr, Cu, Fe, Mn Mo, Ni, P e Zn apresentaram amostras em desacordo com o estabelecido na resolução CONAMA 357. A ficoflórula se caracterizou por apresentar 227 táxons, 95 gêneros, distribuídos em 13 classes taxonômicas. Observou-se uma variação espacial da riqueza, com menor número de espécies nas microbacias em função das condições lóticas destes locais, e maior número de táxons no reservatório. A alta estabilidade da coluna de água e elevada disponibilidade de nutrientes no reservatório propiciaram um expressivo desenvolvimento do fitoplâncton nos pontos lênticos que foram semelhantes quanto à composição e densidade. / The present work aimed at verifying the physical, chemical and biological contribution of the Taquaruçu Grande sub-basin to the reservoir of the Luís Eduardo Magalhães hydroelectric power station, in the medium Tocantins TO, Brazil. Data were collected quarterly in the rainy and dry periods from January 2007 to October 2008, in eight points located in the sub-basin and in the reservoir. Limnologic variables were colletced and analyzed in accordance with CETESB (2006) and APHA (2005), as well as metals and trace elements analyzed by inductively coupled argonium plasma (ICP-OES) atomic absoption spectrometry (AAS) with graphite furnace or hydride generation (Cotrim, 2006). Biologic samples were collected with 20 m plankton net, fixed in Transeau\'s solution (proportion 1:1) for qualitative analysis and in acetic Lugol\'s solution for the quantitative analysis made in a Olympus BX41 microscope. Electric conductivity, water temperature, total dissolved solids, phosphorus and pH showed higher concentration in the lentic points than in the sub-basin, with higher parameters in the rainy period, which is attributed to the amount of allochthonous matter carried by the rain to the reservoir. Nitrate and fixed solids show higher concentration in the reservoir in the dry period. Eutrophycation conditions have become more intense with the rise of the dry weather and can be a consequence of organic matter decomposition processes, which release nitrogen compounds. The higher concentration of fixed solids in the dry period is probably related to the low depth of the points, which favors the resuspension of sediments by the action of winds and local hydrodynamics. Ba, Na, Si, K, Al, Mn, Zn, Li, Mg, P, Ca, Fe and Ag were present in all points in most of the sample period. Samples from October 2007 presented high concentrations of B, Al, Cr, Ni, Cu, Zn, Mo, P, Co and Ag mainly in the sample points of the sub-basin, associated to the low depth of the streamlets, which in this period shown shallow water favoring weathering. Al, Ag, Be, Co, Cr, Cu, Fe, Mn Mo, Ni, P and Zn presented samples in discordance with CONAMA 357. The phytoplankton was characterized by presenting 227 taxons, 95 genus, distributed in 13 taxonomic classes. It was observed a spatial variation of species richness, with a lower number of species in the microbasins due to lotic conditions of these places, and a higher number of taxons in the reservoir. High stability of the water column and elevated nutrient availability propitiated an expressive phytoplankton development in the lentic points similar in composition and density.
283

Influência da toxicidade da água e do sedimento dos rios São Joaquim e Ribeirão Claro na bacia do Corumbataí / Influence of water and sediment toxicity of the São Joaquim and Ribeirão Claro Rivers on the Corumbataí River Basin

Tâmara Guindo Messias 27 August 2008 (has links)
A bacia do rio Corumbataí localizada na região central do estado de São Paulo, abrange parte dos municípios de Analândia, Corumbataí, Santa Gertrudes, Rio Claro, Itirapina, Ipeúna, Charqueada e Piracicaba, durante seu percurso os rios: Passa Cinco, Ribeirão Cabeça e Ribeirão Claro, considerados seus principais afluentes, influenciam significativamente nas características de suas águas. Os testes de toxicidade vêm sendo utilizados e reconhecidos mundialmente como uma ferramenta eficaz no biomonitoramento e na avaliação da qualidade das águas e dos sedimentos. Visando avaliar e entender o decréscimo da qualidade da água e do sedimento do rio Corumbataí, após a afluência das águas do Ribeirão Claro foram analisadas amostras em cinco pontos de coleta: dois no Ribeirão Claro, dois no rio Corumbataí e um no rio São Joaquim. Foram realizados testes ecotoxicológicos com Hydra attenuata, Pseudokirchneriella subcapitata, Chironomus xanthus, Lactuca sativa e Dapnhia magna, determinações físicas, químicas e biológicas para avaliação do IQA e quantificação dos elementos químicos: Be, Al, Na, Mg, Ca, K, V, Mn, Fe, Cr, Co, Ni, Cu, Zn, As, Se, Ag, Cd, Sb, Ba, Hg, Pb, Th, Tl, U por Espectrofotometria de massas com fonte de plasma induzido (ICP-MS). As coletas ocorreram trimestralmente de Abril de 2006 a Maio de 2007. Os resultados das quantificações dos elementos químicos foram comparados aos limites determinados pela Resolução CONAMA 357/05, e observados valores de Al, Fe, Hg e Pb, acima do recomendado. As análises físicas, químicas e biológicas mostraram que o oxigênio dissolvido (OD), fósforo total, nitrogênio amoniacal, demanda bioquímica de oxigênio (DBO5dias) e os coliformes fecais estão fora dos padrões recomendados. A avaliação do IQA aponta Classificação Ruim para todas as amostras do rio São Joaquim, para o Ribeirão Claro três Ruins, uma Boa e uma Imprópria, mostrando a importância destes afluentes para a piora das águas do rio Corumbataí. Todas as amostras de água e sedimento apresentaram toxicidade para pelo menos um dos organismos utilizados, principalmente para H. attenuata, P. subcapitata e C. xanthus. A sensibilidade da H. attenuata esteve diretamente relacionada à presença dos coliformes fecais, Cu, Ag, Ni e Zn, enquanto que a da P. subcapitata esteve relacionada à presença de Zn, Na, DBO e diminuição do OD, segundo as análises estatísticas de redundância (RDA) rodadas pelo R estatístico. Os elementos químicos Al e Fe estiveram presentes nas amostras de água e sedimento, acima do recomendado pelo CONAMA para rios de Classe 2, assim como o Mn, o qual teve sua concentração elevada pelas chuvas, enquanto que os elementos Be, V, Cr, Co, Ni, As, Cu, Cd, Sb, Ba, Pb, Zn e U estiveram abaixo ou próximo aos limites. O sedimento apresentou os elementos biodisponível na seguinte ordem decrescente: Mn > Zn > Ba > Pb > Cu > V > Cr > Co > Ni > As > U > Be > Ag > Cd > Se > Hg > Sb, quando retirado o Al e o Fe. Os rios São Joaquim e Ribeirão Claro influenciaram negativamente a qualidade da água do rio Corumbataí / The Corumbataí river basin located on Central region in São Paulo State is composed by part of Anâlandia, Corumbataí, Rio Claro, Itirapina, Ipeúna, Charqueada and Piracicaba municipality. The principals affluents rivers are Passa Cinco, Ribeirão Cabeça and Ribeirão Claro that have influence on water characteristics of Corumbataí river. The toxicity test has been recommended as an efficient tool for biomonitoring and evaluation of water and sediment quality. With the aim of evaluate and understand the decrease of water and sediment qualities of Corumbataí river five sampling sites were selected: two on Ribeirão Claro river, two on Corumbataí river and one on São Joaquim river. Ecotoxicity tests were performed with Hydra attenuata, Pseudokirchneriella subcapitata, Chironomus xanthus, Lactuca sativa and Dapnhia magna. For evaluation o IQA, were carried out physical, chemical and biology determinations as well chemical elements quantification by ICP-MS, such as: Be, Al, Na, Mg, Ca, K, V, Mn, Fe, Cr, Co, Ni, Cu, Zn, As, Se, Ag, Cd, Sb, Ba, Hg, Pb, Th, Tl and U. The water samples were collected every three mouth from April 2006 to May 2007. The chemical elements quantification results were compared with values standardized by CONAMA 357/05 Resolution. The Al, Fe, Hg e Pb concentration were over the ones recommended. The physical, chemical and biology assays showed that the dissolved oxygen, total phosphorus, ammonia nitrogen, biochemical oxygen demand and fecal coliforms were out of the standard recommendation. The IQA evaluation classified all water samples from São Joaquim River as Bad, the Ribeirão Claro three water samples were Bad, one Good and another Improper. So it showed the importance of these affluents on the decrease of Corumbatai river water quality. All the water and sediment samples showed toxicity at least for one organism tested, mainly for H. attenuata, P. subcapitata e C. xanthus. The H. attenuata sensity were directly affected by fecal coliforms, Cu, Ag, Ni and Zn, meanwhile the P. subcapitata were affect by Zn, Na, DBO and lowest level of OD, as obtained by redundancy analysis (RDA) on R statistics program. The chemical elements Al and Fe were present on water and sediment sample, over the recommend concentration of CONAMA 357/05 Resolution for rivers of Class 2 as the same for the Mn, which had high concentration after rain. On the other hand the elements Be, V, Cr, Co, Ni, As, Cu, Cd, Sb, Ba, Pb, Zn and U were below or near the limits. The sediment showed the chemical elements in this order: Mn > Zn > Ba > Pb > Cu > V > Cr > Co > Ni > As > U > Be > Ag > Cd > Se > Hg > Sb, when the Al and Fe where not considered. The São Joaquim and Ribeirão Claro rivers had a negative influence on Corumbataí river water quality
284

Estimativa da disponibilidade e qualidade das águas da bacia do igarapé Carrapato, em Boa Vista, Roraima

Rubens Gonçalves 15 October 2008 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / This study aimed to investigate the main morphometry, the flow, the water quality and the soil use of the river basin of the igarapé Carrapato, located in Boa Vista, RR. For the morphometry of the basins igarapé Carrapato maps were used in mapping and urveying field with the use of GPS and altimeter. For the flow, measures have been taken with the monthly use of a reel, over a year. For the water quality, in four points of the stretch of main water, water was collected to evaluate the turbidity, the levels of potassium and iron, pH, electrical conductivity, levels of sodium, calcium and magnesium. The climatological water balance (BHC) of the basin was done using the data collected from the basin and the precipitation and evapotranspiration estimated by Penman- Monteith FAO / Este trabalho teve por objetivo principal estudar a morfometria, a vazão, a qualidade da água e o uso do solo da bacia hidrográfica do igarapé Carrapato, localizado em Boa Vista, RR. Para a morfometria da bacia hidrográfica do igarapé Carrapato foram utilizados mapas cartográficos e levantamento em campo com o uso de GPS e altímetro. Para vazão, medidas mensais foram feitas com o uso de um molinete ao longo de um ano. Para a qualidade da água, em quatro pontos do curso d`água principal, a água foi coletada para avaliação da turbidez, dos teores de potássio e ferro, pH, condutividade elétrica, teores de sódio, cálcio e magnésio. O balanço hídrico climatológico (BHC) da bacia foi feito utilizando-se dados de precipitação coletados na bacia e a evapotranspiração estimado por Penman-Monteith FAO
285

Análise multivariada da qualidade da água superficial do Município de Boa Vista - RR

Andréia Cristina SantAna 28 November 2006 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / A cidade de Boa Vista, capital do estado de Roraima, encontra-se inserida à margem direita do Rio Cauamé e à margem direita do Rio Branco, este último formado pela junção dos rios Tacutu e Uraricoera, e cortada pelos igarapés Grande, Caxangá, Mirandinha e Caranã, sendo estes corpos d'água nosso objeto de estudo. O surgimento da cidade se deu a partir da margem direita do rio Branco e seu posterior em direção aos afluentes daquele rio, fez com que atividades antrópicas interferissem sobre maneira na conformação natural dos mesmos, como retirada da mata ciliar, despejo direito de efluentes domésticos e canalização de seus leitos. A partir dessa constatação verificou-se a necessidde da avaliação da qualidade da água superficial do município de Boa Vista, com intuito de auxílio à gestão. Para tanhto, utilizou como ferramenta multivariada por Componentes Principais - PCA e Análise Hierárquica de Cluster - HCA, bem como o cálculo do índice de Qualidade da Água - IQA. / Boa Vista city, capital of Roraima State it is located on the right margin of Cauamé river and on the right margin of Branco river, this last constituted by the joint of Tacutu and Uraricoera rivers, and it is crossed by Grande Brook, Caxangá, Mirandinha and Caranã brooks, being these water streams the object of our study. The city developed from the right margin of Branco river and its later development toward the tributary streams of that river, caused the human activities to interfere greatly in their natural formation, like removing the ciliar woods along the brooks, pouring non treated domestic dejections into them and canalization of their river beds. From this finding out, it was verified to be necessary to evaluate the superficial water quality in Boa Vista, aiming to help is management. In order to obtain this, it was used as multivariate tool the Principal Components Analyses - PCA and Hierarchic Cluster Analyses - HCA, as well as Water Quality Indicator
286

Diagnóstico de uma lagoa de infiltração receptora de efluentes tratados de matadouro visando a conservação da bacia hidrográfica do igarapé Água Boa-RR / Diagnosis of an infiltration pond receiving treated effluent from a slaughterhouse aiming at the conservation of the water catchment area of ​​the igarapé Água Boa-RR

Cíntia de Castro Garcia Martins 12 August 2016 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Realiza o diagnóstico da lagoa de infiltração, receptora do efluente tratado do matadouro e frigorífico Industrial de Roraima - MAFIR, por meio do monitoramento da qualidade do efluente e da área superficial, visando a conservação da bacia hidrográfica do Igarapé Agua Boa, em Boa Vista-RR. / It performs the diagnosis of the infiltration lagoon, receiving the treated effluent from the abattoir and industrial refrigeration of Roraima - MAFIR, by monitoring the effluent and surface area quality, aiming at the conservation of the water catchment area of ​​the Igarapé Água Boa basin in Boa Vista- RR.
287

Detecção de oocistos de Cryptosporidium, spp, em águas de abastecimento superficiais e tratadas da região metropolitana de São Paulo. / Detection of Cryptosporidium spp. in raw and drinking waters in São Paulo city.

Ana Paula Bortolotti Muller 28 February 2000 (has links)
O protozoário parasita Cryptosporidium emergiu como um dos mais importantes contaminantes da água responsável por vários surtos de criptosporidiose, afetando mais de 427.000 indivíduos em todo o mundo. Até hoje, pelo menos oito espécies do gênero Cryptosporidium foram descritas, mas somente o C. parvum têm sido associado às doenças gastroentestinais em humanos. A criptosporidiose pode ser fatal para imunocomprometidos e pode debilitar severamente indivíduos imunocompetentes. Os oocistos de Cryptosporidium são resistentes às pressões ambientais, podendo sobreviver por vários meses no ambiente aquático e são também resistentes à desinfecção por cloro utilizada no tratamento convencional de água. Este estudo teve como objetivos determinar a ocorrência e densidade de Cryptosporidium em amostras de água superficiais e tratadas (após floculação, coagulação, sedimentação, filtração e desinfecção) coletadas em duas Estações de Tratamento de Água da cidade de São Paulo. A relação entre os parâmetros da qualidade da água e a ocorrência de oocistos de Cryptosporidium também foi analisada. As amostras de água foram coletadas em intervalos mensais durante o período de um ano. Estas amostras foram concentradas por ''precipitação do carbonato de cálcio'' (VESEY et alii, 1993a) e através da técnica da ''membrana filtrante'' (ALDOM & CHAGLA, 1994). Os oocistos foram identificados pela técnica de imunofluorescência direta e a presença destes foi confirmada por microscopia de contraste de fase. Os níveis de coliformes totais e E.coli nas amostras de água foram determinados pela técnica dos tubos múltiplos, empregando substrato fluorogênico e cromogênico (Colilert 18, Iddex). De um total de 24 amostras analisadas, de cada tipo de água (sendo 12 de cada Estação de Tratamento de Água), os oocistos foram detectados em 75% das amostras de água bruta e em 12,5% das amostras de água tratada, quando estas foram concentradas por precipitação química e em 73,91% das amostras de água bruta e 33,33% das amostras das água tratada, quando as mesmas foram concentradas pela técnica da membrana filtrante. A densidade de oocistos de Cryptosporidium não apresentou correlação significativa com indicadores microbiológicos e os parâmetros físico-químicos de qualidade da água (p > 0,05). Os resultados obtidos sugeriram que o tratamento de água convencional é ineficaz para a remoção de oocistos, ressaltando a necessidade de estabelecer programas de gerenciamento em bacias hidrográficas (mananciais) que efetivamente garantam a baixa densidade de oocistos de Cryptosporidium em águas / The protozoan parasite Cryptosporidium has emerged as one of the most important contaminants of water, causing waterbone outbreaks of criptosporidiosis which have affected more than 427.000 individuals worldwide. At least 8 species of the genus Cryptosporidium has been associated with gastrointestinal disease in humans. Cryptosporidiosis can be life threatening to immunocompromised humans and can severely debilitate immunocompetent people. Cryptosporidium oocysts are environmentally robust and can survive in aquatic environments for months. Oocysts are resistant to standard chlorination disinfection used for drinking water treatment. The aims of this study were to determine the occurrence and the levels of Cryptosporidium in raw water samples and in drinking water (after flocculation, coagulation, sedimentation, filtration and disinfection) collected in two potable water treatment plants of the city of São Paulo. The relationship between parameters of water quality and the occurrence of Cryptosporidium were also analysed. Samples were collected at monthly intervals for a year. The samples were concentrated by flocculation (VESEY et alii, 1993a) and by membrane filtration (ALDOM & CHAGLA, 1994). The oocysts were identified by direct immunofluorescence assay and the presence was confirmed by phase contrast microscopy. The levels of coliforms and E.coli in the water samples were determined by the multiple tube technique using chromogenic and fluorogenic substrate (Colilert 18, Iddex). From a total of 24 samples of the each type of water investigated (12 oh the each potable water treatment plant), oocysts were detected in 75% of raw water and in 12,5% of drinking water samples, when concentrated by flocculation and in 73,91% of raw water samples and in 33,33% of drinking water samples when concentrated by membrane filtration. Cryptosporidium oocysts levels in the samples investigated was not significantly associated with microbiological indicators and water quality parameters (p > 0,05). The results suggested that the conventional treatment of water is ineffective in removing the oocysts, highlighting the necessity of establishing water catchment management programs which effectively ensure low levels of Cryptosporidium in raw water supplied to the treatment plants.
288

Desenvolvimento e avaliação de um sistema de filtragem com reversão de fluxo de alta frequência / Development and assessment of filtration in irrigation system with high frequency reversal flow

Marinaldo Ferreira Pinto 18 June 2013 (has links)
A obstrução de emissores tem sido um entrave para a microirrigação. Porém, tem-se notado poucos estudos relativos ao desenvolvimento de equipamentos que auxiliam na prevenção da obstrução de emissores nos últimos anos. Os estudos realizados nesta linha estão geralmente ligados à caracterização dos sistemas em uso. O objetivo deste trabalho foi desenvolver um sistema de filtragem com reversão automática de fluxo, de alta frequência. O sistema foi concebido para operar com água de baixa qualidade, com inversão de fluxo e limpezas automáticas e com volume mínimo de água para realização das limpezas. As decisões do controlador do sistema de filtragem têm como base a perda de carga, obtida por meio de transdutores de pressão instalados na entrada e na saída do sistema. O protótipo final é composto, basicamente, por três filtros de tela e onze válvulas solenoides controladas eletronicamente. Determinou-se a curva de perda de carga em função da vazão, a eficiência de retenção e o volume mínimo de água para limpeza dos filtros. A eficiência de retenção de partículas foi determinada em delineamento experimental inteiramente aleatorizado em esquema fatorial, sendo testados três fatores: tempo de reversão (15 e 30 s); incremento da perda de carga (25 e 50%) e concentração de sólidos (500 e 1000 mg L-1). A eficiência de retenção de sólidos totais foi de 71,7 e 78,3% para as concentrações de 500 e 1000 mg L-1, respectivamente, tendo apresentado diferença significativa a 1% de probabilidade. Entretanto, a eficiência retenção de sólidos maiores que 50 ?m (Ed > 50) foi de 98,6 ± 0,7%, não sendo significante para nenhum dos tratamentos ao nível de significância de 1%. O volume médio de água despendido durante as limpezas foi de 5,39 L por limpeza, que representou um volume de água de limpeza por volume de água filtrada de 8,0 e 12,6 L m-3, para as concentrações de 500 e 1000 mg L-1, respectivamente. Os valores de eficiência energética do sistema de filtragem variaram de 80 a 90% para a vazão de 2 m3 h-1 com pressão de entrada entre 15 a 40 mca. As limpezas do sistema de filtragem não foram totalmente eficazes na retomada da perda de carga, com tendência de aumento com o tempo. A inversão de fluxo com frequências de 11,11 e 22,22 mHz influenciou na evolução da perda de carga do sistema de filtragem, tornando-a mais lenta que a evolução para o sistema funcionando sem inversão de fluxo. Considerou-se que o sistema de filtragem desenvolvido apresentou potencial para filtragem da água de irrigação com baixa qualidade, porém necessita de manutenções periódicas para limpeza do elemento filtrante. A perda de carga admissível do sistema de filtragem deve ser o valor mais restritivo entre o critério de desempenho de retenção de partículas e o de variação de vazão do sistema de irrigação. / Emitters clogging have been a barrier to trickle irrigation. Just a few studies have been performed concerning equipments which assist in preventing emitters clogging in recent years, especially regarding to development equipment. Studies carried out on this issue are usually linked to the characterization of systems in use. The aim of this study was to develop a filtering system with automatic flow reversal of high frequency. The system is designed to operate with low quality water, with reverse flow and automatic cleanings and with minimum volume of water to perform the cleaning. Decisions by the controller of the filtration system are based on head loss, obtained by pressure transducers installed at the upstream and downstream of the system. The final prototype consists of three screen filters and eleven electronically controlled solenoid valves. The curve of head loss was determined as a function of water flow, retention efficiency and minimum volume of water required for cleaning the filters. The efficiency in particle retention was determined following a completely randomized experimental design in a factorial scheme in which three factors were tested: reversal time (15 and 30 s) increase in head loss (25 and 50%) and solids concentration (500 and 1000 mg L-1). The total solids retention efficiency was 71.7 and 78.3% for concentrations of 500 and 1000 mg L-1, respectively, presenting a significant difference at 1%. However, when analyzing the retention efficiency of solids larger than 50 ?m (Ed> 50), none of the treatments was significant at 1%, whose efficiency was 98.6 ± 0.7%. The mean volume of water expended during the cleaning was 5.39 L. It represented a volume of water for cleaning per volume of filtered water from 8.0 and 12.6 L m-3, to concentrations of 500 and 1000 mg L-1, respectively. The energy efficiency values of filtering system ranged from 80 to 90% considering flow rate of 2 m3 h-1 and inlet pressure ranging from 15 to 40 mca. The filtering system cleaning was not totally effective in reestablishing the head loss, with an upward trend over time. The reverse flow with frequency of 11.11 and 22.22 mHz influenced the head loss evolution of the filtration system, making it slower than the trend for the system running without flow reversal. The developed filtration system has potential for filtering low quality irrigation water, but it requires periodic maintenance to clean the filter element. The allowable head loss of the filter system should be the most restrictive value between the criterion of particle retention performance and the flow variation of the irrigation system because of the increase in head loss in the filters.
289

Comparação de metodologias para a estimativa do número mais provável (NMP) de coliformes em amostras de água / Comparison of methodologies for estimating the most probable number (MPN) of coliform in water samples

Marina Chiarelli Marquezi 24 September 2010 (has links)
Em quase todos os ambientes aquáticos são encontrados diversos microrganismos, entre eles alguns patogênicos ao homem, que tem como rota de transmissão o ciclo fecal-oral. Pelo fato de a água ser o alimento mais consumido pela população, ela está associada a diversos casos de doenças e de riscos à saúde pública. Assim, o controle da qualidade da água antes do seu consumo é essencial, e para a garantia de sua qualidade devem ser feitas análises que buscam indicar a contaminação por material de origem fecal. O grupo de bactérias mais usado para a determinação de contaminação fecal é o grupo coliformes totais, que tem como subgrupo os coliformes termotolerantes. A bactéria Escherichia coli é integrante do grupo coliforme termotolerante, e é a mais indicada para determinação de contaminação fecal pelo fato de estar presente em grande quantidade em fezes de humanos e animais de sangue quente. Para a análise de bactérias do grupo coliformes totais e E. coli há diversos métodos, entre eles o método convencional de fermentação em tubos múltiplos (FTM) e os métodos rápidos Colilert e Colitag. Este trabalho teve como objetivo comparar estes três métodos para tais análises em amostras de água provenientes de pontos com contaminações distintas (abastecimento, bica e rio), assim como comparar as contagens encontradas de coliformes termotolerantes e E. coli pelo método FTM. Os métodos rápidos Colilert e Colitag se mostraram equivalentes ao FTM nas análises de coliformes totais em amostras de água provenientes de bica e de abastecimento, e nas análises de E. coli em amostras de água de abastecimento, da bica e do rio. Para as análises de coliformes totais em amostras de água do rio o método FTM apresentou uma diferença significativa em relação ao método Colilert e Colitag. Ambos os métodos rápidos não diferiram entre si. A diferença encontrada entre estes métodos nestas análises pode ter ocorrido devido à presença de Aeromonas nas amostras, que podem ter gerado resultados falso-positivos nos métodos rápidos, superestimando a contagem de coliformes totais; ou pela maior capacidade dos métodos rápidos em recuperar células injuriadas de coliformes totais, detectando uma quantidade maior destas bactérias. Na comparação das contagens encontradas para coliformes termotolerantes e E. coli nas mesmas amostras foi encontrada uma diferença significativa. Este resultado é explicado pelo fato de o grupo coliforme termotolerante incluir bactérias de origem não exclusivamente fecal, tais como Enterobacter e Klebsiella, o que pode superestimar a contaminação fecal da amostra. Já a E. coli tem origem exclusivamente fecal, sendo mais indicada para tal análise. Assim, como os métodos rápidos se mostraram equivalentes ao método convencional estudado, devese preferir o uso dos métodos rápidos, que dão o resultado em 24 horas, indicando a qualidade da água a tempo de evitar o uso desta pela população. Na escolha entre as bactérias do grupo coliformes termotolerantes e a E. coli para a indicação da contaminação fecal, deve-se preferir o uso da E. coli. / In almost all aquatic environments are found in various microorganisms, including some pathogenic to man, which route of transmission is the fecal-oral cycle. Because the water is the food most consumed by people, it is associated with several cases of diseases and risks to public health. Thus, control of water quality prior to consumption is essential, and to guarantee its quality must be made analysis seeking to indicate contamination by fecal material of origin. The group of bacteria most commonly used for the determination of fecal contamination is the total coliform group, which has as subgroup thermotolerant coliforms. The bacterium Escherichia coli is a member of the group thermotolerant coliform, and is most suitable for determination of fecal contamination by being present in large quantities in feces of humans and warmblooded animals. For the analysis of bacteria of the group coliform and E. coli there are several methods, including the conventional method Multiple Tube Fermentation (MTF), and the rapid methods Colilert and Colitag. This study aimed to compare these three methods for analysis in water samples from different points with different contamination (supply, fountain and river) and compare the count found for thermotolerant coliform and E. coli by the method FTM. The methods Colilert, Colitag and FTM were equivalent in the analysis of total coliform in water samples from the fountain and supply, and the analysis of E. coli in samples of supply, fountain and river. For analysis of total coliform in water samples from the river, FTM method showes a significant difference compared to the methods Colilert and Colitag. Both rapid methods did not differ. The difference between these methods in these tests may be due to the presence of Aeromonas in the samples, which may have generated false-positive results in rapid methods, overestimating the total coliform count; or the largest capacity of rapid methods in recovering injured cells of coliforms, detecting a larger amount of these bacteria. Comparing the scores found for thermotolerant coliform and E. coli in the same samples was found a significant difference. This result is explained by a thermotolerant coliform group include bacteria not exclusively fecal origin, such as Klebsiella and Enterobacter, which may overestimate the faecal contamination of the sample. Since E. coli is exclusively fecal origin, being more suitable for such analysis. So, as rapid methods showed to be equivalent to the conventional method studied, one should prefer the use of rapid methods that give results in 24 hours, indicating the water quality in time to prevent its use in the population. In choosing between coliform thermotolerant bacteria and E. coli for the indication of fecal contamination, it is preferable to use E. coli.
290

Avaliação da quantidade e qualidade dos recursos hídricos superficiais da bacia hidrográfica do rio Sapucaí-Mirim (SP) através do simulador computacional Mike Basin / Assessment of superficial water resources quantity and quality of Sapucaí-Mirim river basin (SP) through computational Mike Basin

Liliane Lazzari Albertin 08 July 2004 (has links)
Fundamental a vida e ao desenvolvimento de qualquer sociedade, a água é um bem precioso e limitado que está se esgotando e sendo motivo de preocupação mundial. O desperdício, a distribuição desigual, o aumento do consumo e a degradação da qualidade da água são motivos que a tornaram escassa e trouxeram à tona a importância do planejamento e gerenciamento dos recursos hídricos. Frente a esta situação, este trabalho buscou avaliar a disponibilidade hídrica quantitativa e qualitativa da bacia hidrográfica do rio Sapucaí-Mirim, SP. Através da aplicação do simulador hidrológico MIKE BASIN, foi analisado o desempenho do sistema de recursos hídricos, o conflito existente entre os usos múltiplos e a concentração dos parâmetros OD e DBO nas águas do rio que recebe efluentes domésticos, muitos deles sem nenhum tratamento. Apesar da quantidade de água ser suficiente para atender às demandas, o estudo mostra que a geração de energia elétrica está comprometida e a água está se esgotando qualitativamente, evidenciando a necessidade e urgência de se implantar estações de tratamento de esgoto. / Fundamental to the life and to development of any society, water is a precious and limited possession which is running out and has become a world concern. It\'s waste, unequal distribution, increase in the consumption, and degradation of water quality are reasons that have made the water become scarce and bring up the importance of water resources planning and management. Motivate by this situation, this work assessed the quantity and quality of water available at Sapucaí-Mirim river basin, SP. Through of the application of the MIKE BASIN hydraulic simulator, water resources system performance was analyzed, the conflict between the multiples uses of water and the concentration of DO and BOD parameters in the river water that receives domestic wastewater, many of them untreated. Although the quantity water is enough to serve the demand, the study shows that electric power generation is compromising and the water has been scarcity in terms of quality, evidence that it is necessary and urgent to construct new wastewater treatment plants.

Page generated in 0.4334 seconds