101 |
Uma nova metodologia para análise da qualidade da energia elétrica sob condições de ocorrência de múltiplos distúrbios / A new methodology for power quality analysis under multiple disturbance occurrenceMarcelo Antonio Alves Lima 14 October 2013 (has links)
Um Sistema Elétrico de Potência (SEP) está susceptível à presença de diversas fontes de distúrbios que prejudicam a Qualidade da Energia Elétrica (QEE). Desta forma, as suas tensões e/ou correntes podem conter m´múltiplos distúrbios com ocorrência simultânea. Este trabalho apresenta uma metodologia para decomposição do sinal medido em componentes que estimem as formas de onda dos distúrbios individuais quando da ocorrência de m´múltiplos distúrbios, com o posterior reconhecimento de cada um deles. A Análise de Componentes Independentes (ICA) é utilizada como principal ferramenta na etapa de decomposição dos distúrbios. A ICA é originalmente uma t´técnica aplicada em análise multivariada de dados, o que significa que ela necessita de medições realizadas por múltiplos sensores dispostos em diferentes posições de um sistema. No entanto, este trabalho propõe a sua aplicação tendo disponível apenas um sinal medido. Para tanto, são propostos dois métodos para produzir a diversidade necessária para a t´técnica funcionar adequadamente. É demonstrado que ambos os métodos equivalem a um banco de filtros lineares adaptativos capaz de realizar a separação não-supervisionada de múltiplos distúrbios independentes e que sejam espectralmente disjuntos. Por fim, é proposto um sistema de classificação que utiliza Redes Neurais Artificiais (RNAs) para identificar os distúrbios decompostos pela etapa anterior. A metodologia completa é avaliada por meio de testes utilizando dados sintéticos e reais, alcançando resultados altamente satisfatórios para decomposição de sinais contendo múltiplos distúrbios e taxas de acerto globais dos classificadores superiores a 97% / The power system is susceptible to the presence of several sources of disturbances that harm the power quality. In this sense, its voltages and/or currents may contain multiple disturbances with simultaneous occurrence. This work presents a methodology that decomposes the measured signal in components which estimate the waveforms of the individual disturbances followed by their recognition when a multiple disturbance situation occurs. The Independent Component Analysis (ICA) is the main tool in the disturbance decomposition stage. The ICA is originally a technique applied in multivariate data analysis, which means that it requires measurements from multiple sensors allocated in different positions of the system. However, this work proposes its application for a single measured signal available. For this, two methods were developed in order to provide the required diversity to the ICA technique. It is demonstrated that both methods are equivalent to an adaptive linear filter bank capable to perform an unsupervised separation of multiple independent disturbances, if they are spectrally disjoint. A classification system based on artificial neural networks is proposed to identify the disturbances decomposed by the previous stage. The complete system is tested using synthetic and actual data, presenting highly satisfactory results for the decomposition of signals containing multiple disturbances, and precision for the classification task above 97%
|
102 |
Mitigação de variações de tensão causadas pela proteção anti-ilhamento de geradores distribuídos via controle de taps de reguladores de tensão / Mitigating voltage variations caused by the anti-islanding protection of distributed generator via voltage regulator tap controlDaniel Ferreira Lima 04 August 2017 (has links)
A conexão de geradores distribuídos em sistemas de distribuição deve ser cuidadosamente avaliada para que os mesmos auxiliem efetivamente na melhoria do desempenho das redes elétricas, buscando reduzir ou eliminar eventuais situações que causem a degradação da qualidade da energia elétrica fornecida aos consumidores, entre outros aspectos. Neste contexto, existem vários trabalhos que analisam a influência da conexão de geradores distribuídos no perfil de tensão da rede elétrica, frequência, desequilíbrio de fases e distorção harmônica. No entanto, há poucos trabalhos analisando os efeitos da desconexão de geradores distribuídos na qualidade da energia fornecida aos consumidores. Uma vez operando em paralelo com a rede de distribuição, esses geradores influenciam o perfil de tensão e o comportamento dos dispositivos reguladores de tensão. Como consequência, sua desconexão pode provocar variações de tensão intensas causando danos ou mau funcionamento às cargas. A desconexão pode ser repentina ou devido à atuação da proteção anti-ilhamento, seguida dos procedimentos de religamento automático do alimentador, se houver. Visando estudar este problema, o qual tende a se tornar uma nova preocupação das concessionárias de energia elétrica, e no intuito de minimizar e/ou eliminar os possíveis efeitos negativos dessas variações de tensão, esta pesquisa propõe o desenvolvimento de um método de controle dos taps dos reguladores de tensão. Neste método, o controle dos taps foi modelado como um problema de otimização, minimizando as violações de tensão mencionadas anteriormente e também a quantidade de operações dos reguladores de tensão ao longo de um dia típico. A otimização foi solucionada com um Algoritmo Genético e os resultados obtidos indicaram que é possível minimizar as variações de tensão usando a curva de carga do sistema para planejar a operação dos reguladores de tensão. / The connection of distributed generators in an electric power system should be evaluated carefully to ensure that they effectively assist in improving the performance of electrical networks, reducing or eliminating any situations that cause degradation of the power quality of the consumers, and other issues. In this context, there are several studies that analyze the influence of generators connected to distribution systems and how they affect the frequency, cause variations in voltage magnitude, voltage unbalance and harmonic distortion. However, there are a few studies analyzing the effects that the disconnection of distributed generators induces to the power quality of consumers. Once operating in parallel with the distribution network, these generators have an effect on voltage variations and voltage regulator devices. As a result, disconnection can cause severe voltage variations causing damage or malfunction to the loads. The disconnection may be sudden or due to the action of anti-islanding protection, followed by the procedure to reconnect the substation, if it is possible. In order to study this problem, which tends to become a new power quality concern for electric utilities, and in order to minimize and / or eliminate the possible side effects of the voltage variations, this research proposes the development of a control method of voltage regulators\' taps. In this method, the control of taps was modeled as an optimization problem which aimed to minimize these voltage variations aforementioned and also the amount of voltage regulator operations over a typical day. The optimization was solved by a Genetic Algorithm and the results obtained demonstrate that it is possible to minimize the voltage variation by using the system load curve to plan the operation of voltage regulators.
|
103 |
A robustez de um sistema de distribuição e a alocação de medidores de qualidade da energia elétrica frente aos afundamentos de tensão / The robustness of a distribution system and an allocation of power quality monitors in the face of the voltage sagsThais Reggina Kempner 23 March 2012 (has links)
Esta dissertação tem como objetivo inicial reapresentar e difundir o Método das Posições de Falta (MPF) como um meio analítico para se determinar as tensões remanescentes, em todas as barras constituintes de um Sistema de Distribuição (SD), quando da ocorrência de afundamentos de tensão. Pela aplicação de tal método, é possível construir a Matriz de Tensão Durante a Falta (MTDF), denotando assim, a influência e a propagação dos afundamentos de tensão sobre toda a rede. A fim de validar o MPF, será realizada uma comparação dos resultados obtidos com os provenientes de simulações computacionais dispondo do software ATP (Alternative Transients Program). Desta comparação, ilustra-se que a ferramenta indicada mantém a previsão dos resultados em limites aceitáveis, mesmo considerando certa simplificação nos procedimentos de cálculo e na modelagem computacional dos componentes do sistema. A partir dos resultados encontrados, é realizado um mapeamento das áreas de risco que equipamentos eletroeletrônicos sensíveis estarão submetidos, através da delimitação e análise da área afetada e da área exposta ou de vulnerabilidade. Em complementação ao trabalho, é apresentada uma proposta baseada em um algoritmo branch and bound que determinará o número ótimo de medidores de qualidade de energia, bem como as barras onde os mesmos devam ser instalados para monitorar os afundamentos de tensão, com o objetivo de garantir que ao menos um dos medidores seja sensibilizado para cada um dos curtos-circuitos simulados. / This dissertation aims to initially reintroduce and spread the Fault Positions Method (FPM) as an analytic means to determine the remaining voltage in all bus bar constituents of a Distribution System (DS), upon the occurrence of voltage sags. By applying this method, it is possible to formulate the during fault voltage matrix, thus denoting the influence and propagation of voltage sags around the network as a whole. In order to legitimate the FPM, the results obtained are compared to those from computer simulations by use of the ATP (Alternative Transients Program) software. This comparison demonstrates that the tool has maintained the predicted results within acceptable limits, even though some simplification in the procedure for calculating and computer modeling of the system components. Based on such results, a detailed mapping of areas of risk, to which sensitive electronic equipment is subjected, has been carried out through the outlining and analyzing of the affected area and of the exposed or vulnerability area. Adding up to the work, a proposal based on a branch and bound algorithm is presented as a means to determine the optimum number of power quality monitors, and the bus where they should be installed to measure voltage sags, in order to ensure that at least one of the meters is sensitized for each of the simulated short-circuits.
|
104 |
Técnicas para a detecção, classificação e localização no tempo das variações de tensão de curta e longa duração / Techniques for detection, classification and location in time of short and long-time voltage variationsLetícia Caldeira Pereira Rodrigues 12 September 2008 (has links)
Os objetivos deste trabalho vão da apresentação do andamento das pesquisas relacionadas à análise de distúrbios associados à qualidade da energia elétrica (QEE), até a proposta de um algoritmo baseado em diversas ferramentas para a detecção e localização no tempo, bem como a classificação automática destes distúrbios. Nesta pesquisa é proposta uma detecção não somente do início e fim de um único evento, mas também, de n possíveis desconformidades na forma de onda que possam vir a ocorrer ou existir em determinados registros e/ou arquivos de dados em análise. Como diferencial deste trabalho, tem-se que da determinação da localização das alterações/descontinuidades na forma de onda, foi possível obter janelas de dados com tamanhos flexíveis. Desta maneira, vários eventos sobre o sinal em análise puderam ser avaliados, bem como as durações associadas. Para isso, a Transformada Wavelet (TW) foi utilizada para realizar a detecção e também a localização destas alterações no tempo. Já para a classificação da ocorrência, ou das ocorrências, a TW, a Transformada de Fourier (TF) e o valor RMS foram empregados. A flexibilidade das janelas de dados permitiu uma adequada escolha de qual ferramenta poderia ser mais bem utilizada na classificação. Conforme implementado, cada uma destas ferramentas apresenta uma resposta e através de um módulo de decisão lógica é determinada a resposta final do algoritmo. Para validar o estudo, várias situações de distúrbios foram caracterizadas referentes a um sistema elétrico de distribuição real, implementado e simulado pela aplicação do software ATP (Alternative Transients Program). Os resultados obtidos foram excelentes tanto para a detecção e localização no tempo, como para a classificação e estimação da amplitude e duração dos eventos. / The objectives of this work are going since the presentation of the researches related to the analyses of power quality (PQ) disturbances through the proposal of an algorithm based on several tools for detection and location in time, as well as the automatic classification of these phenomena. It is proposed to determine not only the initial and the end of a unique event, but all the n possible disconformities in the waveform that can exist or occur in the data file registered data in analyses. As the differential of this research, from the location in time of the alteration/discontinuities in the waveforms, it was possible to obtain data windows with flexible sizes. So, several events on the signal were evaluated, as well as their specific timeduration. For this purpose, the Wavelet transform (WT) was used to reach the detection and localization in time of the waveform alterations. For the event classification, the TW, the Fourier transform (FT) and the Root Mean Square (RMS) value were used. The data window flexibility allowed an appropriate choice of which tool could be better used in the classification task. As implemented, each one of these tools presented an answer, and the final answer was obtained by using a logic decision module. To validate the study, some situations of disturbances were characterized using a real distribution system, implemented and simulated applying the ATP (Alternative Transients Program) software. The results were excellent in such a way for detection and localization in time, as well as for the automatic classification and estimation of the magnitude and the event duration.
|
105 |
Modelagem multiobjetivo para o problema da alocação de monitores de qualidade da energia em sistemas de distribuição de energia elétrica / Multiobjective modeling for the problem of allocation of power quality monitors in electrical distribution systemHermes Manoel Galvão Castelo Branco 30 July 2013 (has links)
Problemas ocasionados por perturbações na qualidade da energia elétrica (QEE) podem provocar sérios prejuízos, tanto de cunho social, quanto financeiros, aos clientes conectados ao sistema elétrico de potência como um todo. Neste contexto, os clientes que mais sofrem são os clientes industriais, pois estes possuem cargas sensíveis a vários distúrbios associados à falta da QEE. Sendo assim, para adoções de medidas preventivas, ou corretivas, que melhorem os índices de QEE, faz-se necessário um monitoramento dos sistemas elétricos que permita um melhor acompanhamento da ocorrência dos distúrbios. Nesta pesquisa é proposta a modelagem do problema de alocação ótima de monitores de QEE em sistemas de distribuição com múltiplos objetivos, os quais são: minimização do custo do monitoramento, minimização da ambiguidade topológica, maximização do monitoramento das cargas, maximização da quantidade de ramais monitorados, minimização da quantidade de afundamentos não monitorados, e maximização da redundância do monitoramento dos afundamentos. Na resolução do problema foi utilizado o Algoritmo Evolutivo Multiobjetivo com Tabelas (AEMT), adotado por ter boa capacidade de resolução com muitos objetivos. Os resultados obtidos permitiram observar que o AEMT forneceu as fronteiras de Pareto com soluções diversificadas e bem distribuídas ao longo da mesma, mostrando-se de grande relevância para o planejamento de sistemas de monitoramento da QEE em sistemas de distribuição de energia. A principal contribuição desta tese é o fornecimento de um modelo que permite às empresas de energia avaliar os investimentos que farão nos seus sistemas de monitoramento considerando seis critérios distintos, permitindo uma maior flexibilidade no estabelecimento do plano de monitoramento e uma melhor análise do custo/benefício considerando os seis aspectos abordados. / Problems arising from disturbances in power quality (PQ) can cause serious damage, both social, and financial, to customers connected to the electrical power distribution systems as a whole. In this context, the customers who suer most are industrial customers, as they have loads sensitive to various disturbances associated with the lack of PQ. Thus, in order to adopt preventive or corrective measures to improve PQ rates, it is necessary to monitor electrical systems to allow better oversight of the occurrence of disturbances. In this research, the proposal is to model the problem of optimal allocation of power quality monitors in distribution systems with multiple objectives. The multiple objectives are: minimizing the monitoring cost, minimizing ambiguities in topology, maximizing the load monitoring, maximizing the area monitoring, minimizing the voltage sag unmonitored, and maximizing the redundancy in the sag monitoring. In solving the problem, a Multiobjective Evolutionary Algorithm with Tables (MEAT) was adopted due to ability to deal with many objectives. The results show that the AMET finds a set of ecient solutions that are diversified and well-distributed along the Pareto Front, and that they are highly relevant for planning of PQ monitoring systems in electrical power distribution systems. The main contribution of this thesis is to provide a model that allows utilities better evaluate investments that they will make in their monitoring systems comprising six dierent criteria, allowing greater flexibility in establishing the monitoring plan and a better analysis of cost/benefit considering the six aspects.
|
106 |
Uma nova abordagem para a análise da estabilidade a pequenas perturbações em sistemas de distribuição de energia elétrica com geradores síncronos distribuídos / A new approach to the analysis of stability for small disturbances in distribution systems of electric power distributed synchronous generatorsRodrigo Hartstein Salim 19 April 2011 (has links)
Nesta tese de doutorado, a estabilidade a pequenas perturbações é estudada sob a ótica dos sistemas de distribuição de energia elétrica com geradores síncronos distribuídos. Duas peculiaridades específicas destes sistemas são abordadas: o desequilíbrio da carga e da rede e a proximidade das cargas aos geradores. Em relação ao primeiro tópico, duas abor dagens são propostas para o estudo de estabilidade a pequenas perturbações em sistemas com desequilíbrio da carga, uma delas baseada na estimação modal a partir de dados obtidos através de medições ou simulações no domínio do tempo, e a outra baseada na modelagem fasorial do sistema com desequilíbrio da carga e posterior linearização do sistema algébrico-diferencial não-linear obtido. Em relação ao segundo tópico, constatam-se nesta tese que as oscilações eletromecânicas podem induzir certos fenômenos de qualidade de energia, notadamente as flutuações de tensão. Nesta tese, uma estrutura é proposta e critérios são definidos para o estudo destas flutuações induzidas por problemas tipicamente relacionados à estabilidade, considerando o estudo de perturbações isoladas e também o estudo estatístico de perturbações. Através desta análise, é proposto também um procedimento de projeto de controladores de amortecimento com critérios bem definidos para auxiliar na mitigação destas flutuações de tensão induzidas por oscilações eletromecânicas. Tal procedimento de projeto é complementar aos índices de desempenho do sistema dinâmico tipicamente utilizados para o projeto destes controladores em sistemas de transmissão. Os significativos avanços em ambos os tópicos abordados abriram um vasto campo de trabalho a ser estudado do ponto de vista da estabilidade a pequenas perturbações de sistemas de distribuição com geradores síncronos distribuídos. / In this thesis, the small-signal stability is studied from the perspective of power distribution systems with distributed synchronous generators. Two specific peculiarities of these systems are addressed: the load and network unbalance, and the proximity of loads to generators. Regarding the first topic, two approaches are proposed to the small-signal stability study of power systems with load unbalance, one based on modal estimation through data obtained from measurements or time-domain simulations, and another one based on a phasorial model of the system with load unbalance and later linearization of the differential-algebraic nonlinear system obtained. Regarding to the second topic, it is observed in this thesis that electromechanical oscillations can induce certain power quality phenomena, notably voltage fluctuations. In this thesis, a structure is proposed and criteria are defined to the study of these fluctuations induced by typical stability problems, considering the study of isolated perturbations and also the statistical study of perturbations. Through this analysis, a procedure for the design of power system stabilizers with clearly defined criteria is also proposed to assist in mitigating the voltage fluctuations induced by electromechanical oscillations. This design procedure is complementary to the stability criteria currently used in the design of power system stabilizers for power transmission systems. The significant advances in both studied topics have also opened a large research field related to the small-signal stability of power distribution systems with distributed synchronous generators.
|
107 |
Análise da robustez e da sensibilidade de sistemas de distribuição para a alocação otimizada de medidores frente às variações de tensão de curta duração / Analysis of the robustness and sensitivity of distribution systems for optimal allocation of monitors in face of Short Duration Voltage VariationsThais Reggina Kempner 19 May 2016 (has links)
Como as Variações de Tensão de Curta Duração (VTCDs) estão entre as perturbações mais difíceis de serem monitoradas, uma vez que são ocasionadas por fatores aleatórios e imprevisíveis, a monitoração do Sistema de Distribuição (SD) representa uma providência essencial para a obtenção de informações representativas para a regulamentação de novos indicadores relativos a esses distúrbios. Neste cenário, este trabalho busca garantir a completa observabilidade das VTCDs em SD, quando da incidência de qualquer tipo de curto-circuito, através da alocação ótima de medidores. Para a determinação da magnitude da tensão em cada nó do SD é utilizado o método das posições de falta, denotando assim, a influência e a propagação das VTCDs sobre a rede como um todo. Na sequência, é determinada uma matriz binária resultante que observa os afundamentos de tensão de forma simultânea para todos os tipos de faltas. Posteriormente, é proposta a redução desta matriz para diminuir o esforço computacional em SDs de grande porte. Ainda, é analisada a vulnerabilidade de cada nó do SD para estabelecer a sua posterior ponderação no processo de otimização. Os resultados revelam que a metodologia de alocação apresentada torna o processo de obtenção da solução ótima ágil e direto, pois menos execuções computacionais são necessárias para obter diferentes soluções ótimas e garantir a monitoração dos afundamentos de tensão para todos os tipos de curtos-circuitos. Além disso, pela metodologia, tem-se também a prioridade de instalação dos medidores conforme a maior observabilidade dos afundamentos de tensão, possibilitando a escolha do melhor arranjo de medidores que atenda aos limites orçamentários das distribuidoras de energia. / Short Duration Voltage Variations (SDVVs) are among the most difficult disturbances to be monitored, since they are caused by random and unpredictable factors. Hence, the Distribution System (DS) monitoring is an essential step for obtaining representative information for the regulation of new power quality indices for these disturbances. In this scenario, this work aims to ensure the entire observability of SDVVs, considering any short circuit occurrence in the DS, based on algorithm to achieve the monitors\' optimal allocation. In order to determine the voltage magnitude at each node, the fault positions method is used, showing the influence and propagation of SDVVs on the DS. Subsequently, a resulting binary matrix is determined. This matrix observes the voltage sags, simultaneously, for all fault types. Then, the downsizing of this matrix is proposed in order to reduce the computational effort in large DSs. Furthermore, the vulnerability of each DS node is analyzed to establish the relative weighting in the optimization process. The results show a faster and more direct allocation methodology to obtain the optimal solution, because fewer computational executions are needed for different optimal solutions and to ensure the voltage sags monitoring for all short circuits types. Moreover, the power quality monitor installation priority is performed according to the higher observability of the voltage sags, making it possible to choose the best arrangement of monitors that meets the budget constraints of the power utilities.
|
108 |
Metodologia para diagnóstico e análise da influência dos afundamentos e interrupções de tensão nos motores de indução trifásicos / Methodology for the diagnosis and analysis of influence of voltage sags and interruptions in three-phase induction motorsGerson Bessa Gibelli 20 May 2016 (has links)
Nesta pesquisa, é proposta uma metodologia para detectar e classificar os distúrbios observados em um Sistema Elétrico Industrial (SEI), além de estimar de forma não intrusiva, o torque eletromagnético e a velocidade associada ao Motor de Indução Trifásico (MIT) em análise. A metodologia proposta está baseada na utilização da Transformada Wavelet (TW) para a detecção e a localização no tempo dos afundamentos e interrupções de tensão, e na aplicação da Função Densidade de Probabilidade (FDP) e Correlação Cruzada (CC) para a classificação dos eventos. Após o processo de classificação dos eventos, a metodologia como implementada proporciona a estimação do torque eletromagnético e a velocidade do MIT por meio das tensões e correntes trifásicas via Redes Neurais Artificiais (RNAs). As simulações computacionais necessárias sobre um sistema industrial real, assim como a modelagem do MIT, foram realizadas utilizando-se do software DIgSILENT PowerFactory. Cabe adiantar que a lógica responsável pela detecção e a localização no tempo detectou corretamente 93,4% das situações avaliadas. Com relação a classificação dos distúrbios, o índice refletiu 100% de acerto das situações avaliadas. As RNAs associadas à estimação do torque eletromagnético e à velocidade no eixo do MIT apresentaram um desvio padrão máximo de 1,68 p.u. e 0,02 p.u., respectivamente. / This study proposes a methodology to detect and classify the disturbances observed in an Industrial Electric System (IES), in addition to, non-intrusively, estimate the electromagnetic torque and speed associated with the Three-Phase Induction Motor (TPIM) under analysis. The proposed methodology is based on the use of the Wavelet Transform WT) for the detection and location in time of voltage sags and interruptions, and on the application of the Probability Density Function (PDF) and Cross Correlation (CC) for the classification of events. After the process of events classification, the methodology, as implemented, provides the estimation of the electromagnetic torque and the TPIM speed through the three-phase voltages and currents via Artificial Neural Networks (ANN). The necessary computer simulations of a real industrial system, as well as the modeling of the TPIM, were performed by using the DIgSILENT PowerFactory software. The logic responsible for the detection and location in time correctly detected 93.4% of the assessed situations. Regarding the classification of disturbances, the index reflected 100% accuracy of the assessed situations. The ANN associated with the estimation of the electromagnetic torque and speed at the TPIM shaft showed a maximum standard deviation of 1.68 p.u. and 0.02 p.u., respectively.
|
109 |
Otimização multiobjetivo da compensação de potência reativa em redes de distribuição considerando restrições de distorção harmônicaAZEVEDO, Manoel Socorro Santos 14 November 2014 (has links)
Submitted by Edisangela Bastos (edisangela@ufpa.br) on 2015-05-19T22:30:14Z
No. of bitstreams: 2
license_rdf: 22974 bytes, checksum: 99c771d9f0b9c46790009b9874d49253 (MD5)
Tese_OtimizacaoMultiobjetivoCompensacao.pdf: 1385522 bytes, checksum: f28192c0b6b8ec65f18eb07c8458c66f (MD5) / Approved for entry into archive by Ana Rosa Silva (arosa@ufpa.br) on 2015-05-20T14:36:25Z (GMT) No. of bitstreams: 2
license_rdf: 22974 bytes, checksum: 99c771d9f0b9c46790009b9874d49253 (MD5)
Tese_OtimizacaoMultiobjetivoCompensacao.pdf: 1385522 bytes, checksum: f28192c0b6b8ec65f18eb07c8458c66f (MD5) / Made available in DSpace on 2015-05-20T14:36:25Z (GMT). No. of bitstreams: 2
license_rdf: 22974 bytes, checksum: 99c771d9f0b9c46790009b9874d49253 (MD5)
Tese_OtimizacaoMultiobjetivoCompensacao.pdf: 1385522 bytes, checksum: f28192c0b6b8ec65f18eb07c8458c66f (MD5)
Previous issue date: 2014 / A localização de bancos de capacitores nas redes de distribuição de energia elétrica,
corretamente dimensionados, busca compensar eventuais excessos de circulação de potência
reativa pelas linhas, o que implica a redução de custos operacionais pela redução das perdas
de energia e um aumento da capacidade de transmissão de potência ativa assegurando os
níveis estabelecidos de tensão e fator de potência simultaneamente. A proliferação das cargas
não lineares provocou uma mudança nos cenários de estudo dos sistemas elétricos de potência
devido aos efeitos nocivos que os harmônicos gerados por elas ocasionam sobre a qualidade
da energia elétrica. Considerando este novo cenário, esta tese tem como objetivo geral
desenvolver uma ferramenta computacional utilizando técnicas de inteligência computacional
apoiada em algoritmos genéticos (AG), para a otimização multiobjetivo da compensação da
potência reativa em redes elétricas de distribuição capaz de localizar e dimensionar de forma
ótima as unidades de compensação necessárias para obter os melhores benefícios econômicos
e a manutenção dos índices de qualidade da energia estabelecidos pelas normas brasileiras.
Como Inovação Tecnológica do trabalho a ferramenta computacional desenvolvida permite
otimizar a compensação da potência reativa para melhorar do fator de potência em redes de
distribuição contaminadas com harmônicos que, diferentemente de métodos anteriores, não só
emprega bancos de capacitores, mas também filtros de harmônicos com esse objetivo. Utiliza-se
o algoritmo NSGA-II, que determina as soluções ótimas de Pareto para o problema e
permite ao especialista determinar as soluções mais efetivas. A proposta para a solução do
problema apresenta várias inovações podendo-se destacar que a solução obtida permite
determinar a compensação de potência reativa com capacitores em sistemas com certa
penetração harmônica, atendendo a normas de qualidade de energia pertinentes, com relação
aos níveis de distorção harmônica tolerados. / The localization of capacitors banks in the electric power distribution networks,
correctly sized, looks for to compensate eventual excesses of circulation of reactive power for
transmission lines, what implies the reduction of operational costs for the reduction of the
energy losses and an increase of the capacity of transmission of active power assuring the
established levels of voltage and power factor simultaneously. The proliferation of the
nonlinear loads produced a change in the scenarios of study of the electric power systems due
to the degradation effects that the harmonic generated by them cause about the quality of the
electric power. Considering this new scenario, this thesis has as general objective to develop a
computational tool using computational intelligence supported in genetic algorithms (GA), for
the multiobjective optimization of the reactive power compensation in distribution electric
networks able to locate and size in a good way the necessary compensation units to achieve
the best economic benefits and the maintenance of the indexes of quality of the energy settled
down by the Brazilian norms. As technological innovation of the work, the developed
computational tool allows to optimize the compensation of the reactive power to improve the
power factor in polluted distribution networks with harmonics that, differently of previous
methods, not alone it uses capacitors banks, but also harmonic filters with that objective. The
NSGA-II algorithm is used to determine optimal solutions of Pareto for the problem and it
allows the specialist to determine the most effective solutions. The formulation proposed in
this thesis for the solution of the problem presents several novelties being able to highlight
that the achieved solution allows to determine the compensation of reactive power in systems
with certain harmonic penetration, complying with pertinent standards of power quality, with
respect to the tolerated levels of harmonic distortion.
|
110 |
Análise não paramétrica para identificação de fontes de distorções harmônicas em sistemas de energia elétrica: um estudo aplicado no campus universitário do Guamá da Universidade Federal do ParáMATOS, Edson Ortiz de 19 February 2016 (has links)
Submitted by camilla martins (camillasmmartins@gmail.com) on 2017-03-15T17:26:40Z
No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Tese_AnaliseNaoParametrica.pdf: 5858237 bytes, checksum: 2ad3f6f508cede019d85d5bec0b35c8f (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-03-22T14:04:50Z (GMT) No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Tese_AnaliseNaoParametrica.pdf: 5858237 bytes, checksum: 2ad3f6f508cede019d85d5bec0b35c8f (MD5) / Made available in DSpace on 2017-03-22T14:04:50Z (GMT). No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Tese_AnaliseNaoParametrica.pdf: 5858237 bytes, checksum: 2ad3f6f508cede019d85d5bec0b35c8f (MD5)
Previous issue date: 2016-02-19 / Atualmente, o uso de cargas não lineares e equipamentos baseados em eletrônica de potência nas instalações residenciais, comerciais e industriais estão contribuindo para o aumento significativo dos níveis de distorção harmônica de corrente e, consequentemente de tensão, conforme observado no sistema brasileiro de distribuição de energia elétrica. O aumento contínuo dos níveis de distorção harmônica nas redes elétricas de distribuição tem causado preocupação nas concessionárias e clientes de energia, pois a presença dessas fontes de harmônico no sistema provoca, entre outros, perda da qualidade no fornecimento de energia. Com foco neste problema, a presente tese propõe o desenvolvimento de modelos de regressão não paramétrica para identificar e quantificar quais cargas não lineares podem ser consideradas fontes harmônicas principais, para as distorções de tensão em um ponto de interesse da rede elétrica. A metodologia proposta se baseia na análise de correlação de dados, utilizando modelos estatísticos de regressão não paramétrica para estabelecer a correlação entre as correntes harmônicas das cargas não lineares e a tensão harmônica no ponto de interesse. Este modelo é construído a partir das tensões e correntes harmônicas de mesma ordem respectivamente, obtidas em campanhas de medição através de qualímetros instalados nos pontos de interesse. Além disso, deve-se salientar que essas tensões e correntes harmônicas devem estar em sua unidade base, ao invés de grandezas normalizadas em relação à componente fundamental, de forma a impedir que a mesma influencie na criação do modelo de regressão. Um aspecto importante nesta metodologia está na utilização das técnicas de regressão polinomial local de Kernel, para a estimação das curvas de regressão entre a tensão e a corrente harmônica. Na validação dos modelos introduz-se o coeficiente de determinação R2, o qual pode ser obtido a partir do coeficiente de correlação de Pearson, para mensurar o grau de precisão dos modelos desenvolvidos. A regressão não paramétrica proporciona uma grande flexibilidade na estimação do modelo de regressão, uma vez que a mesma torna possível à realização de um ajuste mais efetivo do modelo às amostras de dados, e, portanto, é capaz de caracterizar a influência de cada fonte harmônica de forma mais detalhada para todo o período de medição. Essa técnica, apresentou resultados muito mais confiáveis e supera as deficiências dos modelos de regressão linear, o qual impõe que as correntes harmônicas das outras fontes, background, não variam quando se analisa uma determinada corrente de carga. Os modelos de regressão linear e não paramétrico foram simulados aplicando-se o programa R, que é uma linguagem e ambiente para cálculos estatísticos e gráficos, e como sistema teste utilizou-se a rede de distribuição elétrica da Universidade Federal do Pará, constituído de 84 (oitenta e quatro) barras de carga em tensão de 13,8 kV. Os resultados obtidos são comparados aos modelos de regressão linear e apresentaram bom desempenhos possibilitando sua aplicação por empresas de distribuição de energia elétrica. / Nowadays, the use of non-linear loads and power electronics-based equipment in residential, commercial and industrial facilities are contributing to the significant increase of current harmonic distortion levels and, consequently voltage harmonic distortions, as noted in the Brazilian distribution systems. Increasing levels of harmonic distortion in electrical distribution networks is a concern to electric utilities and customers, because the presence of these harmonic sources causes, among others, loss of quality in the energy supply. With a focus on this problem, this thesis proposes the development of non-parametric regression models to identify and quantify what non-linear loads can be considered main sources of voltage harmonic distortion at a point of interest in the electric network. The proposed methodology is based on data correlation analysis, using non-parametric regression statistical models to establish the correlation among the non-linear loads harmonic currents and harmonic voltage at a point of interest. This model is built from harmonic voltage and currents measurements, obtained in measuring campaigns using power quality analyzers installed at the points of interest. In addition, it should be pointed out that these harmonic voltages and currents must be express in base units, rather than percent values in relation to the fundamental component, in order to prevent the influence in the creation of the regression model. An important aspect in this methodology is the use of techniques based on Kernel local polynomial regression, for the estimation of the regression model between harmonic voltage and current. To validate the models it is introduced the determination coefficient R2, which can be obtained from the Pearson correlation coefficient, to measure the accuracy degree of the developed models. The non-parametric regression procedure provides a great flexibility in the estimation of regression models, since it makes possible to carry out a more effective model fit to the data samples, and therefore it is able to characterize the influence of each harmonic source in more detail for the entire measurement period. This technique presented more reliable results and overcomes the shortcomings of the linear regression model, which requires the harmonic currents of other sources, called background, not to vary when analyzing a particular load current. The linear and non-parametric regression models were simulated using the program R, which is a language and environment for statistical calculations and graphs, and as test system it was used the Federal University of Pará electric distribution network, consisting of 84 (84) load busbars in 13.8 kV. The results so obtained are compared to those obtained with the linear regression models, and presented good performance, allowing its application for electric power distribution companies.
|