• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 806
  • 687
  • 106
  • 64
  • 41
  • 40
  • 35
  • 26
  • 11
  • 8
  • 6
  • 5
  • 5
  • 5
  • 5
  • Tagged with
  • 2226
  • 2226
  • 660
  • 658
  • 369
  • 203
  • 188
  • 185
  • 177
  • 163
  • 156
  • 148
  • 122
  • 121
  • 120
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
721

Estabelecimento de requisitos de desempenho em dosimetria e proteção radiológica nos serviços de mamografia digital de Minas Gerais / Establishment of performance requirements in dosimetry and radiation protection in digital mammography facilities digital in the state of Minas Gerais

Sabrina Donato da Silva 23 January 2014 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Segundo dados do Cadastro Nacional de Estabelecimentos de Saúde (CNES), o Estado de Minas Gerais possui aproximadamente 477 mamógrafos em uso. Destes, estima-se que em torno de 200 são digitais utilizando, principalmente, sistemas de radiografia computadorizada (CR) ou radiografia direta (DR). A mamografia é insubstituível no diagnóstico e detecção precoce do câncer de mama, principal causa de morte entre mulheres no mundo. Um alto padrão de qualidade da imagem, aliada com uma dose tão baixa quanto razoavelmente exequível, são essenciais para esta detecção precoce de forma segura, levando a necessidade de controle de qualidade através do processo de otimização dos procedimentos. Dentro deste contexto este estudo teve como objetivo determinar a dosimetria e a qualidade da imagem em 72 combinações mamógrafo/CR e DRs em 68 serviços de mamografia do Estado de Minas Gerais, o que corresponde aproximadamente 14% do total de mamógrafos atualmente em uso no Estado de Minas Gerais e a cerca de 34% dos mamógrafos digitais em uso (CRs e DRs). O teste que avalia a linearidade da resposta do detector mamógrafico atendeu aos critérios de desempenho especificados pela Sociedade Espanhola de Física médica em 85% dos equipamentos avaliados. Porém dos serviços que apresentaram não conformidade nesse quesito apenas dois apresentaram menos de quatro anos de uso do mamógrafo. Possivelmente o tempo de utilização dos mamógrafos esteja relacionado a não conformidade apresentada por esses serviços. A relação contraste ruído mostrou-se ser um ponto crítico na cadeia de produção da imagem em sistemas digitais, principalmente para maiores espessuras de acrílico. Mais da metade dos serviços avaliados nessa pesquisa obtiveram um bom desempenho na relação sinal ruído (SNR), e na avaliação da imagem através do simulador de contraste e detalhe CDMAM. Em relação ao ruído da imagem a maioria dos serviços ficaram não conformes. Na avaliação da dose glandular média realizada com simuladores de mama, a média geral dos valores de doses obtidos ficaram dentro dos limites considerados aceitáveis na literatura, para a maioria das espessuras simuladas de mama. Porém os resultados obtidos nesse teste são preocupantes, pois a maioria dos sistemas digitais avaliados ficaram não conformes nesse quesito em pelo menos uma espessura de acrílico avaliada, e além disso houve um aumento considerável da dose glandular média em comparação a medidas anteriores realizadas no Estado de Minas Gerais. Já na comparação da dose glandular média entre sistemas CR e DR os sistemas DR apresentaram doses consideravelmente menores para maiores espessuras, em comparação com os sistemas CR. Em relação à comparação entre avaliações subsequentes a amostra seguiu o comportamento geral dos serviços avaliados nesta pesquisa, com exceção da SNR que apresentou um pior desempenho entre as avaliações subsequentes e o ruído, que apesar do baixo índice de conformidade obteve uma melhora entre uma avaliação e outra. Apesar dos potenciais benefícios que podem ser alcançados com o uso do sistema CR e DR, o emprego dessa tecnologia precisa ser revisto e otimizado para que possa oferecer imagens de qualidade utilizando a menor dose possível de radiação. / According to the National Registration of Health Establishments (CNES), there are approximately 477 mammographs operating in the state of Minas Gerais, of which, roughly estimating, 200 are digital apparatus using mainly computerized systems of radiography (CR) or direct radiography (DR). Mammography is irreplaceable in the diagnosis and early detection of breast cancer, the main cause of death in women worldwide. A high standard of image quality coupled with a dose as low as reasonably practicable, are essential for early detection of this disease with safely, leading to the need for quality control through optimization of process procedures. Within this context, this study aimed to determine dosimetry and image quality on 72 mammography combinations / CR and DR in 68 mammography services in the State of Minas Gerais, which represents approximately 14% of mammography units currently in use in the State of Minas Gerais and about 34% in use of digital mammography (CRs and DRs). The test evaluates the linearity of response of the detector mammographic met the performance criteria specified by the Spanish Society of Medical Physics in 85% of evaluated equipment. However, the services they showed non-compliance in this regard, only two were less than four years of use of mammography. Possibly the time of use of mammography is related to noncompliance by these services. The contrast noise ratio proved to be a critical point in the production chain image in digital systems, especially for thicker acrylic. More than half of the services evaluated in this study showed good performance in signal noise, and image evaluation by the phantom contrast and detail CDMAM. Regarding the image noise, most services were non-compliance. In evaluating the average glandular dose with breast phantom, the overall average dose values obtained were within acceptable limits in the literature for most of the simulated breast thicknesses. However the results of that test are troubling, since most digital systems evaluated were non-compliant in this regard at least one thick acrylic evaluated, and in addition there was a considerable increase in the average glandular dose compared to previous measurements performed in the State of Minas Gerais. In comparison between the average glandular dose in CR and DR systems, the DR systems showed significantly lower doses for greater thickness as compared with the CR systems. Regarding the comparison between subsequent reviews, the sample followed the general behavior of the services evaluated in this study, except the SNR had a worse performance between subsequent evaluations and noise, which despite the low level of compliance achieved an improvement between evaluation and other. Therefore, despite the potential benefits that can be attained with the use of the CR and DR systems, the employment of this technology has to be revised and optimised so that a better quality image can be achieved and the radiation dose reduced as much as possible.
722

INSPEÇÃO DE QUALIDADE NA SEPARAÇÃO DE PEDIDO: UM ESTUDO DE CASO EM UM CENTRO DE DISTRIBUIÇÃO.

Nobre, Silvio da Silva 14 April 2015 (has links)
Made available in DSpace on 2016-08-10T10:40:26Z (GMT). No. of bitstreams: 1 SILVIO DA SILVA NOBRE.pdf: 2654031 bytes, checksum: 931855cb07ec68ce9752f099cbb3b45f (MD5) Previous issue date: 2015-04-14 / The Distribution Centers (DC) has embarked on a major role in the supply chain, to the extent that manage much of logistics that is implemented and controls the storage from its origin to its final point. Among the processes of a CD, is the shipment of product for subsequent separation. Distribution Centers implement the fractional separation (rack flow) have constantly problems conference output products, waste and increasing the quality of decreasing process. This work aims to analyze the quality of separation and inspection of rack flow of products on a CD in order to ensure the quality of delivery to the final consumer. One high error rate in the separation process and also inspection of products and proposed an alternative in the inspection process was detected for identify errors and correct them. The results showed that the proposed process and analyzed, based on a precision scale, decreased the return of errors and identified the inspection errors in order to practically zeroing them. In addition, based on the results, analyzed and proposed a modification of the separation process. / Os Centros de Distribuição (CD) vem empenhando um papel importante na cadeia de suprimentos, na medida que gerenciam grande parte de logística que é implementada e controla o armazenamento desde sua origem até ao seu ponto final. Dentre os processos de um CD, encontra-se o de separação de produtos para posterior expedição. Centros de Distribuição que implementam a separação fracionada (flow rack) apresentam, constantemente, problemas de conferência de produtos de saída, aumentando o desperdício e dminuindo a qualidade do processo. Este trabalho tem como objetivo analisar a qualidade da separação e inspeção dos produtos do flow rack em um CD, a fim de garantir a qualidade da entrega para o consumidor final. Foi detectado um alta taxa de erros no processo de separação e também de inspeção dos produtos e proposta uma alternativa no processo de inspeção para indentificar os erros e corrigi-los. Os resultados obtidos demonstraram que o processo proposto e analisado, baseado em uma balança de precisão, diminuiram os erros de devolução e identificaram os erros de inspeção de forma a praticamente a zerá-los. Além disto, baseados nos resultados, analisada e proposta uma modificação do processo de separação.
723

Implantação de um programa de controle de qualidade em equipamentos de raios x por meio de medidores não invasivos / Establishment of an X radiation equipment quality control programme using non invasive meters

Rodrigo Ferreira de Lucena 14 September 2010 (has links)
O objetivo desse trabalho foi estudar o comportamento do principal equipamento de raios X utilizado nos procedimentos do laboratório de calibração do IPEN, LCI, operado nos intervalos de tensão de 25 a 150 kV utilizando os medidores de tensão não invasivos DiavoltTM da PTW e do sistema de espectrometria ORTEC, modelo NOMAD-PLUS 92X para o estabelecimento de um programa de controle de qualidade. O medidor Diavolt foi utilizado para as medições de kerma no ar, tensão de pico e tensão de pico prático. As medições foram feitas variando parâmetros como, corrente elétrica, Qualidade de Radiação X para Radiodiag-nóstico, angulação do medidor e sua distância em relação ao ponto focal do aparelho de raios X. Os resultados encontrados foram comparados com dados encontrados na literatura. Com o sistema de espectrometria, foram gerados os espectros com a finalidade de determinar as tensões de pico relativas às tensões nominais escolhidas e caracterizar as Qualidades em Radiodiagnóstico determinadas anteriormente. O programa de controle de qualidade estabelecido possibilita o controle do funcionamento tanto dos instrumentos de medição (câmaras de ionização, medidor de tensão e corrente e espectrômetro), bem como do sistema de radiação X. Neste trabalho também foi sugerida a periodicidade de realização de cada um dos testes. / The objective of this work was to study the behavior of the mainly X ray equipment calibration laboratory of IPEN, operated in the range from 25 kV to 150 kV using a PTW non invasive meter, model DiavoltTM, and an ORTEC spectrometry system, model NOMAD-PLUS 92X, for the establishment of a quality control programme. The Diavolt meter was used for measurements of air kerma, peak voltage and practical peak voltage. The measurements were made varying parameters such as electrical current, X radiation quality for radiation diagnostic, angulations of the meter and its distance in relation to the focal spot of the X ray tube. The results were compared with data found in the literature. Several spectra were generated with the spectrometer system with the purpose of determine the peak voltage in function of the nominal voltage and to characterize the radiation qualities for radiation diagnostic previously determined. The established quality control programme enables the management of the appropriate functioning of the measurement instruments (ionization chambers, voltage and current meter and spectrometer) as well as of the X radiation system. This work also has proposed a time interval to run each one of the tests.
724

Determinação de Sn(II) por polarografia: aplicação no controle de qualidade de reagentes liofilizados para radiodiagnóstico / Polarographic determination of Sn(II): application in the quality control of radiopharmaceutical reagents

Lugon, Marcelo di Marcello Valladão 11 July 2008 (has links)
Cloreto estanoso (SnCl2.2H2O) é o composto mais utilizado na redução do íon pertecnetato (TcO4-), obtido pela eluição do gerador, para a marcação de reagentes liofilizados para radiodiagnóstico. Estes reagentes liofilizados contêm um ligante, cloreto estanoso, e diferentes excipientes. Muitos métodos analíticos para a determinação de estanho não conseguem distinguir entre os íons estanoso (Sn(II)) e estânico (Sn(IV)) em soluções. Os dois métodos, descritos na literatura, para determinação seletiva de Sn(II) são análise titrimétrica e polarografia. O método mais confiável descrito para a quantificação do íon estanoso é a polarografia (voltametria) e pode ser utilizado para a determinação em concentrações de mg e g de Sn(II) e Sn(IV) (0,06-1,0 mg), com boa seletividade. Foi realizada análise titrimétrica, para quantificação de Sn(II), na matéria-prima e em 3 lotes consecutivos de 9 reagentes liofilizados produzidos pelo IPEN-CNEN/SP, utilizando-se sulfato cérico 0,1 mol L-1, diluído 10 vezes e iodo 0,05 mol L-1, diluído 10 vezes, como soluções titulantes. Polarografia por pulso diferencial foi utilizada com configuração convencional composta por três eletrodos: eletrodo de trabalho de gota de mercúrio, eletrodo referência de Ag/AgCl (saturado com KCl) e eletrodo auxiliar de platina. O intervalo de potencial analisado foi de -250 a -800 mV e o pico atribuído à redução de Sn(II) foi encontrado em -370 mV em eletrólito suporte de H2SO4 3 mol L-1 e, para Sn(IV), -470 mV, em eletrólito suporte de HCl 3 mol L-1. Para retirada do oxigênio da solução na cela polarográfica utilizou-se nitrogênio 5.0 por 5 minutos, antes e após cada introdução de amostra. Para determinação de Sn(IV) foi feita a oxidação do Sn(II), por adição de peróxido de hidrogênio, em 37 ± 5 ºC, por 5 minutos, seguida de purga com nitrogênio, e análise. A análise polarográfica desenvolvida mostrou-se adequada para a determinação de Sn(II), na presença de Sn(IV), e de estanho total nos kits radiofarmacêuticos estudados. / Stannous chloride (SnCl2.2H2O) is the major compound used for reduction of generator-derived 99mTc-pertechnetate in cold kits for on site preparation of 99mTc-radiopharmaceuticals. These cold kits usually contain a ligand, stannous chloride, and different additives. Various techniques were described for tin determination, but they cannot distinguish between stannous (Sn(II)) and stannic (Sn(IV)) ions in solutions. The two methods described in literature for selective determination of Sn(II) are polarography and mass analysis (redox-titration). Polarography is a good selective method in the mg range as well as in the g range for Sn(II) and Sn(IV) (0.06-1,0mg). Titrimetric analysis was performed for quantification of Sn(II) in Sn(II) reagents and in 3 consecutive lots of 9 radiopharmaceutical cold kits produced by IPEN-CNEN/SP, using Ce(SO4)2.4H2O 0.1 mol L-1, diluted 10 times and, I2 0.05 mol L-1, diluted 10, as a titrant solution. Differential pulse polarography was chosen with a conventional three-electrode configuration consisting of a static mercury drop electrode, an AgCl/Ag (saturated KCl) reference electrode and a platinum wire auxiliary electrode. The potential was swept from 250 to 800 mV and the current (A) was measured at 370 mV and 470 mV potentials for Sn(II) in H2SO4 3 mol L-1 and Sn(IV) in HCl 3 mol L-1, respectively. The supporting electrolytes were deaerated during 5 min with 5.0 nitrogen gas before and after each sample addition. For total tin determination the oxidation of tin (II) was carried out in the same vial, by adding H2O2 at 37 ± 5 ºC, for 5 min to quantify tin (IV). The developed polarographic method showed to be adequate to quantify tin (II), in the presence of tin (IV), in analyzed radiopharmaceutical cold kits.
725

Implementação e aceite de sistema de radioterapia de feixe modulado dinâmico com o uso de colimador secundário de múltiplas folhas / Commisioning and implantation of the dynamic intensity modulated radiation therapy using secondary multi-leaf collimator (MLC)

Cecilio, Paulo José 14 October 2008 (has links)
A radioterapia de feixe de intensidade modulada (IMRT) no seu modo dinâmico é uma forma de radioterapia tri-dimensional (3D), na qual modula-se um feixe de forma a obter-se a irradiação com campos que possuem perfil variável. Os campos são gerados por um sistema de otimização matemático e transformado em seqüências de movimento ou abertura de lâminas dos colimadores terciários de múltiplas folhas (MLC) ou feixe colimado helicoidal, reproduzindo a fluência de radiação adequada. No processo o operador atribui valores limitantes de dose ao alvo e aos órgãos de risco circunvizinhos para que o sistema de planejamento inverso realize a otimização possível. Após a aprovação do plano de tratamento o mesmo deve ser conferido, através de um controle de qualidade (CQ), onde são verificadas as doses que deverão ser administradas ao paciente, comprovando-se as doses obtidas e aprovadas no plano do sistema de planejamento (SPC). Para este controle os mesmos feixes e campos são medidos em termos de dose absorvida e perfis, através de dosimetria na qual comprova-se que não há erro físico ou dosimétrico no plano que irá tratar o paciente com diferença aceitável de até 5%, também utilizada como tolerância para a aprovação dos 460 casos avaliados nesta tese. Foram apresentados as metodologias para a aceitação no primeiro serviço a utilizá-la no Brasil e os testes de controle de qualidade de dois serviços de radioterapia, desde agosto de 2001 à maio de 2006 e no outro serviço de outubro de 2007 a maio de 2008, com controle de qualidade que permitiram os respectivos tratamentos clínicos com dados de 4 anos, ou seja, 460 casos com 3935 campos de tratamento verificados individualmente por dosimetria. Isto possibilitou o aperfeiçoamento da metodologia e garantia da qualidade nos tratamentos de IMRT dinâmico destes pacientes. / The intensity modulated radiation therapy (IMRT) is a type of radiation therapy using dynamic sliding window which modulated the beamlets of each field which are thus obtained as a variable profile. The multiple fields are obtained by mathematic optimization in special treatment planning system. In this way, the resulted field is generated by leaf sequencing using the multi-leaf collimator (MLC) or helicoidally beam. The optimization is an interactive process with operator and planning system where the dose prescription to target and dose limit for organ of risk are inserted to obtain the acceptable beam fluence and this process is named as inverse planning. The planning approved by physician should checked by means of dosimetry in order to assure the correct dose delivery; this action is the main task of a quality control (QC) program. The QC is performed by measurements of total absorbed dose and profile for each field planned for the patient. The acceptance level is 5% for total dose and was used for all 460 cases and 3935 fields analyzed between August 2001 to May 2006 at Albert Einstein Hospital and October 2007 to May 2008 at the Centro Infantil Dr. Boldrini. This work performs an analysis of the QC of treatments plans for all patients treated with IMRT. During four years the methodologies were frequently improved and upgradated for each tumor site and could thus be assured for the required quality of all treatments with dynamic IMRT.
726

Estudo e determinação de fatores de influência das dimensões dos frascos de radiofármacos utilizados no IPEN para calibração de ativímetros / Study and determination of the influence factors of the radiopharmaceutical vials dimensions used for activimeter calibration at IPEN

Martins, Elaine Wirney 25 October 2010 (has links)
A eficiência e a segurança de uma prática de medicina nuclear dependem, entre outros fatores, de um programa de controle de qualidade, principalmente no que diz respeito à utilização de medidores de atividade de radionuclídeos (ativímetros). Dentre as maiores fontes de erro nas medidas realizadas com um ativímetro estão: a espessura, o tamanho e o volume do frasco que contém o radiofármaco, considerando que um ativímetro típico tem a sua resposta reconhecidamente dependente do frasco utilizado. O propósito desse trabalho foi implantar um programa de controle de qualidade além de estabelecer fatores de correção referente à geometria do frasco de vidro para distribuição de radiofármacos e calibração de ativímetros, considerando que o Laboratório de Calibração de Instrumentos (LCI) do Instituto de Pesquisas Energéticas e Nucleares (IPEN) possui um Sistema Padrão Secundário NPL-CRC radionuclide calibrator, fabricado pela Southern Scientific, composto por uma câmara de ionização tipo poço e um sistema de medida de corrente, com rastreabilidade ao National Physical Laboratory (NPL) e calibrado com um frasco de vidro tipo P6 que possui dimensões diferentes dos utilizados pelo IPEN. Foram testados os radiofármacos 67Ga, 131I, 201Tl e 99mTc, todos produzidos pelo IPEN. Os resultados demonstraram uma variação de até 22% para o radiofármaco 201Tl, sendo que a menor variação foi encontrada para o 131I (2,98%). Os fatores de correção encontrados devem ser incorporados na calibração rotineira dos ativímetros. / The efficiency and safety of the nuclear medicine practice depend, among others factors, of a quality control programme, mainly related to the use of the nuclide activity meters (activimeter). One of the most important sources of errors in the activimeter measurements is the thickness, size and volume of the vial that contains the radiopharmaceutical considering that a typical activimeter has its response dependent of the vial used. The objective of this work was to establish a quality control programme and the correction factors for the geometry of the vials used for distribution of radiopharmaceutical and activimeters calibration, considering that the Calibration Laboratory of Instrumentos (LCI) of the Instituto de Pesquisas Energéticas e Nucleares (IPEN) has a NPL-CRC Secondary Standard Radionuclide Calibrator System, manufactured for the Southern Scientific plc, compound by an ionization chamber well type and a current measurement system, with traceability to National Physical Laboratory (NPL) and calibrated with a P6 vial type with different dimensions of the one used for the IPEN. The radiopharmaceutical produced by IPEN 67Ga, 131I, 201Tl and 99mTc, had been tested using the two different vials. The results shown a maximum variation of 22% for 201Tl, and the minimum variation was 2.98% for 131I. The correction factors must be incorporated in the routine calibration of the activimeters.
727

Identificação de planta medicinal baseada em espectrocospia e lógica fuzzy. / Signature of medicinal plant using spectroscopy and fuzzy logic.

Severo, Rosane Beatriz Oliveira 14 December 2009 (has links)
A presente tese de doutorado discorre sobre o método da espectroscopia na região do Infravermelho Próximo, usando Transformada de Fourier (IVP-TF), aplicada à identificação de plantas medicinais, método de análise química qualitativa, que se propõe para o controle de qualidade de fitoterápicos. É apresentado, também, um método computacional, implementado para realizar esta identificação, utilizando modelo e lógica nebulosos (fuzzy). Remete-se a discussão da espectroscopia IVP-TF como um método rápido e de baixo custo, para taxonomia de plantas medicinais brasileiras, bem como promove-se a comparação dos resultados obtidos nos diferentes métodos utilizados. / This doctoral thesis is about the method of Near Infrared spectroscopy using Fourier transform (FT-NIR), applied to identification of medicinal plants, method of the chemical analysis qualitative, which is proposed to the quality control of herbal medicines. It is presented, also, a computational method, implemented to make this identification using fuzzy logic model. Refers to discussion of FT-NIR spectroscopy as a rapid method with low cost for taxonomy of Brazilian medicinal plants, and makes comparison of results obtained in the different methods used.
728

Método polarográfico na determinação da viabilidade da vacina BCG liofilizada / Polarographic method for determining the viability of the lyophilized BCG vaccine

Malucelli, Maria Ivette Carboni 06 August 1991 (has links)
Tendo em vista os vários problemas envolvendo a metodologia correntemente utilizada para a determinação da viabilidade no controle de qualidade da vacina BCG liofilizada, foi levado a efeito um estudo a respeito do assunto. Foi procedido um estudo de métodos alternativos a serem empregados em procedimentos de controle de qualidade da vacina BCG liofilizada. Com esse objetivo foi desenhado e construído um polarógrafo de eletrodo de oxigênio constituído de eletrodo de platina e o de referência de Ag-AgCl embutido em peça única e ainda dotado de sensor de temperatura, com circuito eletrônico permitindo a medida de consumo de oxigênio. Levou-se a efeito, então, estudo comparativo de viabilidade de vacina BCG liofilizada pela medida polarográfica de consumo de oxigênio em comparação à manométrica pelo clássico método de Warburg e o método de contagem de colônias (UFC). A análise de 66 diferentes lotes de vacina BCG liofilizada produzidas pelo Instituto Butantan, São Paulo, e pela Fundação Ataulpho de Paiva, Rio de Janeiro, demonstrou que a técnica polarográfica revelou ser altamente reprodutível e muito mais conveniente que os métodos manométrico e de contagem de colônias. Verificou-se que entre o método polarográfico e o manométrico e UFC os resultados da regressão linear mostraram correlação positiva de alta intensidade e significante ao nível de a= 0,05, permitindo indicar o método polarográfico descrito, como procedimento de escolha para operações de controle de qualidade em laboratórios de produção de vacina BCG bem como em Unidades de Saúde, para determinações adequadas de viabilidade de lotes de vacinas, a serem utilizadas para fins de imunização. / Considering the several problems regarding the procedures currently employed in the assays o f the control of quality, and the viability of the freeze-dried BCG vaccines, a study on various methods used for this purpose was carried out. Aiming to introduce a much more suitable, sensitive and less time consuming method than the classic Warburg technique and the colony count test (CFU) bacteriological procedure, currently used, a new oxygen electrode polarograph was designed with the aim of employing it for the study of the viability of the freeze-dried BCG vaccine. This polarograph electrode was built in a single piece containing the platinun and theAgAgCl reference electrode besides a temperature sensor. By using this assembly a comparative study was carried on the viability of the freeze-dried BCG vaccine assayed by the polarographic method in comparison with the manometric and the CFU methods. The analysis of the viability of 66 different batches of freeze-dried BCG vaccines produced at the Butantan Institute, São Paulo, and at the Ataulpho de Paiva Foundation, Rio de Janeiro, demonstrated that the polarograpbic technique revealed to be highly reliable and much more convenient than both the manometric and the CFU methods: it has been found out that between the polarographic and the manometric and the CFU, the linear regression sbowed a high intensity positive correlation and significant at the level of a = 0,05. In this way, the polarographic method could be considered as a choice method for the control of quality procedure as well as for the establishment of the viability of the batches of vaccines to be used for human immunization in Units of the Health Department.
729

Controle da qualidade de projetos de edificações / Quality control for building designs

Ulrich, Helen 02 March 2001 (has links)
Discussão sobre a qualidade de projetos para edificações, com o objetivo de colaborar para o desenvolvimento de um sistema de controle da qualidade dos mesmos. A introdução dos conceitos de qualidade e produtividade no setor da construção civil é abordada segundo os princípios e teorias da Engenharia de Produção, onde destaca-se a importância do papel do projeto como sistematizador de todas as informações necessárias à execução. A qualidade do projeto influi diretamente na eficiência de todas as fases do processo de produção de edificações, e seu efetivo controle determina o sucesso da atividade de projeto. São realizados estudos de caso junto a empresas construtoras e escritórios de projeto, buscando caracterizar a atividade de projeto e analisar iniciativas de melhorias, que, juntamente com a análise do referencial teórico abordado, servem como base para a proposição de diretrizes para o controle da qualidade de projetos de edificações. Conclui-se que a atividade de projeto é um dos gargalos da construção civil e que as iniciativas de melhorias em busca de qualidade desta atividade contribuem com a evolução do setor como um todo. / The quality of building designs is discussed, for the purpose of cooperate with the development of a quality control system for building designs. The introduction of quality concepts in construction is also discussed, in accordance with the principles and theories of Production Engineering. This work recognizes design activity as being the sole informative source essential to construction. The quality of the design process directly influences the efficiency of ali the phases of construction, and its effective control determines the design activity success. Some case studies were carried out, aiming to identify and characterize the design activity in construction enterprises and design offices as well as identifying initiatives of quality improvement. The results of these case studies along with a theoretical analysis form the basis to propose some guidelines for the quality control in building designs. It is concluded that design activity is one of the most important phases in building construction, and that initiatives to improve its quality will contribute to the evolution of the entire construction process.
730

Deadline-ordered parallel iterative matching with QoS guarantee.

January 2000 (has links)
by Lui Hung Ngai. / Thesis (M.Phil.)--Chinese University of Hong Kong, 2000. / Includes bibliographical references (leaves 56-[59]). / Abstracts in English and Chinese. / Chapter 1 --- Introduction --- p.1 / Chapter 1.1 --- Thesis Overview --- p.3 / Chapter 2 --- Background & Related work --- p.4 / Chapter 2.1 --- Scheduling problem in ATM switch --- p.4 / Chapter 2.2 --- Traffic Scheduling in output-buffered switch --- p.5 / Chapter 2.3 --- Traffic Scheduling in Input buffered Switch --- p.16 / Chapter 3 --- Deadline-ordered Parallel Iterative Matching (DLPIM) --- p.22 / Chapter 3.1 --- Introduction --- p.22 / Chapter 3.2 --- Switch model --- p.23 / Chapter 3.3 --- Deadline-ordered Parallel Iterative Matching (DLPIM) --- p.24 / Chapter 3.3.1 --- Motivation --- p.24 / Chapter 3.3.2 --- Algorithm --- p.26 / Chapter 3.3.3 --- An example of DLPIM --- p.28 / Chapter 3.4 --- Simulation --- p.30 / Chapter 4 --- DLPIM with static scheduling algorithm --- p.41 / Chapter 4.1 --- Introduction --- p.41 / Chapter 4.2 --- Static scheduling algorithm --- p.42 / Chapter 4.3 --- DLPIM with static scheduling algorithm --- p.48 / Chapter 4.4 --- An example of DLPIM with static scheduling algorithm --- p.50 / Chapter 5 --- Conclusion --- p.54 / Bibliography --- p.56

Page generated in 1.4656 seconds