• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 25
  • 13
  • 3
  • 2
  • 1
  • Tagged with
  • 44
  • 44
  • 11
  • 6
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Validierung eines semi-quantitativen Ansatzes zur Risikobeurteilung in der Eisenbahntechnik /

Bepperling, Sonja-Lara. January 2009 (has links)
Diss. Univ. Braunschweig, 2008. / Literaturverz.
22

Analytik von Isoflavonen aus Soja, Rotklee und Iris sowie deren Quantifizierung in Nahrungsergänzungsmitteln

Stürtz, Melanie January 2008 (has links)
Zugl.: Braunschweig, Techn. Univ., Diss., 2008
23

Spatial and Temporal Dynamics of Civil Resistance in War Contexts

Krtsch, Roman 12 April 2022 (has links)
Civil wars and intrastate conflicts are characterized by the armed confrontation between the government of a sovereign nation state and at least one non-state group. Accordingly, conflict research has traditionally put an emphasis on analyzing the dynamics of violence between these actors. Recent findings yet suggest that civil war contexts are also increasingly characterized by another type of—mostly nonviolent—behavior: Non-combatants like social movement organizations and local communities, but also armed actors themselves occasionally rely on methods of civil resistance like street protests or general strikes. These behavioral patterns present a fundamental puzzle: Why do rebel groups that normally rely on armed tactics resort to these rather atypical forms of resistance? And how can we explain that civilians even in these highly threatening environments manage to organize collective action in order to articulate their demands? Although a nascent strand of research has examined the occurrence of wartime protests, the influence of conflict-endogenous factors on these phenomena has hitherto been largely neglected. This dissertation aims at addressing this gap and investigates the spatial and temporal dynamics of civil resistance in war contexts. In the course of four research papers, I analyze under which conditions both armed rebel groups and civilian actors use respective tactics. Moreover, I explore how wartime dynamics affect civil resistance both during and in the immediate aftermath of fighting. The results show a strong association between spatial and temporal conflict dynamics on the one hand and the occurrence of civil resistance on the other hand. With the examination of the influence of conflict-endogenous processes, these results contribute to a thriving strand of literature in conflict research that puts an emphasis on the investigation of civil resistance in war contexts.
24

Quantitative NMR-Spektroskopie in der pharmazeutischen Analytik -- Identität, Reinheit und Gehalt von Arzneistoffen / Quantitative NMR spectroscopy in pharmaceutical analysis -- Identity, purity and content of drugs

Beyer, Tanja January 2011 (has links) (PDF)
Das Ziel der vorliegenden Arbeit war die Klärung der Fragestellung, ob sich die quantitative NMR-Spektroskopie zur Bestimmung von Identität, Reinheit und Gehalt von Arzneistoffen eignet, und wie sich Präzision und Empfindlichkeit dieser Methode im Vergleich zu etablierten chromatographischen Verfahren verhalten. Die quantitative Untersuchung der drei strukturell jeweils verwandten Mehrkomponentengemische Codergocrinmesilat, Clomifencitrat und Flupentixoldihydrochlorid bewies eindrucksvoll die Eignung der 1H-NMR-Spektroskopie als orthogonale, analytische Messmethode im Vergleich zu validierten HPLC-Arzneibuchmethoden. Die im Rahmen einer Validierung der 1H-NMR-Methode ermittelten Ergebnisse erfüllten bezüglich Präzision und Richtigkeit die an eine im pharmazeutischen Bereich eingesetzte analytische Methode gestellten Anforderungen; zudem wurden weitere Prüfparameter wie Selektivität, Linearität, Robustheit und Stabilität verifiziert. Externe-Standard-Experimente wie "Zwei-Röhrchen-Methode" und ERETIC-Verfahren bestätigten die quantitativen Ergebnisse der Internen Standardisierung; jedoch wurde hier -- insbesondere für die ERETIC-Technik -- eine höhere Fehleranfälligkeit und somit eine größere Streuung der Einzelergebnisse beobachtet. Am Beispiel von Codergocrinmesilat und Flupentixoldihydrochlorid konnte zudem die Eignung anderer NMR-aktiver Kerne wie 13C und 19F für die quantitative Analyse von komplexen Substanzgemischen aufgezeigt werden. Das Potential der 1H-NMR-Spektroskopie für die Reinheitsprüfung von Arzneistoffen wurde am Beispiel der Aminosäure L-Alanin aufgezeigt. Die zu erwartenden Verunreinigungen Glutamin-, Asparagin-, Äpfel- und Fumarsäure konnten im Gegensatz zu den "veralteten" Prüfmethoden des Europäischen Arzneibuches eindeutig identifiziert und quantifiziert werden; mit einer Bestimmungsgrenze von <= 0.03% wurden die Vorgaben der ICH-Richtlinie Q3A(R2) erfüllt. Die deutliche Übereinstimmung der NMR-spektroskopisch ermittelten Ergebnisse einer quantitativ untersuchten Alanin-Modellmischung mit einer für den Routinebetrieb geeigneten HPLC-Methode unter Einsatz verschiedener Detektoren wie CAD, NQAD, ELSD und MS, sowie der Vergleich wichtiger Prüfparameter wie Linearität und Nachweisgrenze bestätigten die Eignung der 1H-NMR-Spektroskopie im Rahmen der routinemäßig durchgeführten Qualitätskontrolle. Die Aufdeckung von Arzneimittelfälschungen mit Hilfe der NMR-Spektroskopie wurde im Rahmen dieser Arbeit anhand der zwei aktuellen Fallbeispiele Heparin und Glycerin näher untersucht. Die in Zusammenhang mit dem Heparin-Skandal verantwortliche Kontaminante OSCS konnte neben Dermatansulfat und weiteren natürlich vorkommenden Glykosaminoglykan-Verunreinigungen im 1H-NMR-Spektrum eindeutig identifiziert und auf 0.1% OSCS bzw. 0.5% Dermatansulfat begrenzt werden. Eine präzise und richtige quantitative Bestimmung der beiden Glykosaminoglykane wurde über die N-Acetyl-Resonanzen mit Hilfe der Signalhöhenbestimmung und dem Standard-Additionsverfahren ermöglicht; deutliche Abweichungen vom "wahren" Gehalt wurden hingegen, bedingt durch starke Signalüberlagerungen, nach Flächenvergleich beobachtet. Weitere Verunreinigungen, insbesondere Lösungsmittelrückstände, die während des Extraktions- und Reinigungsprozesses des Heparins eingesetzt werden, konnten ebenfalls über charakteristische Resonanzen identifiziert und mit Hilfe der Internen-Standard-Methode quantitativ erfasst werden. Eine umfangreiche Untersuchung von 145 Heparin-API-Mustern mittels NMR-Spektroskopie und weiteren, neuentwickelten Verfahren wie HPLC, CE, IR- und Raman-Spektroskopie konnte die Eignung der entwickelten 1H-NMR-Methode bestätigen. Potentielle Glycerin-Kontaminanten wie Diethylenglycol und Ethylenglycol konnten ebenso wie eine weitere, natürlich vorkommende Verunreinigung, Propylenglycol, mittels 1H- und 13C-NMR-Spektroskopie identifiziert und quantifiziert werden. Beide Methoden erfüllten die in der USP beschriebenen Anforderungen, die für pharmazeutisch eingesetztes Glycerin jeweils höchstens 0.1% Diethylenglycol bzw. Ethylenglycol erlaubt. Während die quantitative Reinheitsprüfung beim Einsatz der 1H-NMR-Spektroskopie mit einer Messdauer im Bereich von etwa 30 min für den Routineeinsatz geeignet ist, ist die entwickelte quantitative 13C-NMR-Methode beim Einsatz von Spektrometern geringer Magnetfeldstärke aufgrund einer geringen Nachweisempfindlichkeit und der NOE-Problematik für den Routinebetrieb nur bedingt anwendbar. Abschließend kann zusammengefasst werden, dass die untersuchten Beispiele die NMR-Spektroskopie als in hohem Maße geeignet für die quantitative Analyse von Arzneimitteln ausweisen. / The main objective of the present thesis was the investigation of the suitability of quantitative NMR spectroscopy for identification, purity assay, and quantification of a given drug, as well as a comparison of precision and sensitivity of this method with well-established chromatographic routines. The quantitative analysis of the three multi-component drug mixtures codergocrine mesylate, clomiphene citrate, and flupentixol dihydrochloride strikingly demonstrates the suitability of the 1H NMR spectroscopy as an independent analytical measurement technique in comparison to validated HPLC methods of international pharmacopoeias. Concerning precision and accuracy, the results obtained from validation of the 1H NMR method met the requirements that are made on an analytical routine for pharmaceutical purposes; additionally, further validation parameters such as selectivity, linearity, robustness, and stability have been verified. Experiments like the "twin tube" and ERETIC techniques utilizing external standards confirm these results; however, in this context an increased error rate and therefore larger variance was observed, especially in the case of ERETIC. By means of codergocrine mesylate and flupentixol dihydrochloride, additionally the suitability of other NMR active nuclei as 13C or 19F for quantification of complex mixtures was shown. The potential of the 1H NMR spectroscopy for purity assays was demonstrated for the example of the amino acid L-alanin. Identification and quantification of the expected impurities glutamic acid, aspartic acid, malic acid, and fumaric acid was possible, in contrast to "out-dated" test methods of the European Pharmacopoeia; achieving a limit of quantification <= 0.03%, the demands of the ICH guideline Q3A(R2) have been met. Concerning the quantification of an alanine model mixture, the clear agreement between the results obtained by means of NMR spectroscopy and a HPLC method using various detectors like CAD, NQAD, ELSD, and MS, suited for routine analysis, as well as the comparison of various relevant parameters such as linearity and limit of quantification confirmed the qualification of 1H NMR spectroscopy in the field of routine quality assurance. Within the scope of this work, the disclosure of counterfeit drugs by means of NMR spectroscopy was investigated in detail utilizing two current case studies, namely heparin and glycerin. Besides dermatan sulfate and other natural occurrences of glycosaminoglycan impurities, the contaminant OSCS revealed in connection with the recent heparin affair was clearly identified in the 1H NMR spectrum and these contaminants could be limited to 0.1% OSCS and 0.5% dermatan sulfate, respectively. A precise and accurate quantification of these two glycosaminoglycanes was achieved using signal height and standard addition methods applied to the N-acetyl resonances; comparison of signal areas however yielded considerable deviations from the "true" content, which are due to strong signal overlap. Further contaminants, especially solvent residues originating from the extraction and purification processes of heparin, have been able to be identified with the help of characteristic resonances; their quantification was possible. An extensive study of 145 heparin API samples by means of NMR spectroscopy and other novel techniques such as HPLC, capillary electrophoresis, IR and Raman spectroscopy confirmed the qualification of the developed 1H NMR method. Potential contaminants in glycerin such as diethylene glycol and ethylene glycol have been able to be identified as well as quantified by means of 1H and 13C NMR spectroscopy, as was the case for propylene glycol, which is naturally present. Both methods met the requirements of the USP, limiting the amount of diethylene glycol and ethylene glycol for pharmaceutical purposes to 0.1%, respectively. While 1H NMR spectroscopy with a measurement time of about 30 min is well suited for routine application, the applicability of the 13C NMR method is limited due to the NOE effect and the low sensitivity at low field strengths. In conclusion, each of the attended topics showed, that NMR spectroscopy is a powerful tool within the framework of quantitative drug analysis.
25

Kapillarelektrophoretische Trennung und Quantifizierung von Aminoglykosiden und Clotrimazol / Separation and quantification of aminoglycosides and clotrimazole by means of capillary electrophoresis

Wienen, Frank January 2003 (has links) (PDF)
Im Rahmen dieser Arbeit wurden kapillarelektrophoretische Methoden entwickelt, mit denen es möglich ist, Gentamicinsulfat in Haupt- und Nebenkomponenten zu trennen. Ausgelöst wurden die Untersuchungen im Jahr 2000, da in den USA über 60 Patienten durch Gentamicin starben. Es wurde vermutet, dass dies auf Verunreinigungen in gewissen Chargen zurückzuführen ist. Gentamicin wird fermentativ aus Micromonospora purpurea gewonnen. Durch leichte Abweichungen im Herstellungsprozess können Produkte entstehen, die mit den bisher angewendeten Analysenmethoden nicht nachzuweisen sind. In der momentanen Arzneibuch-Monographie von Gentamicinsulfat wird zur Prüfung der verwandten Substanzen eine HPLC-Methode beschrieben, die Gentamicin ohne Derivatisierung mit einem gepulsten amperometrischen Detektor detektiert. Vorteil dieser Methode ist, dass Gentamicin nicht derivatisiert werden muss. Der große Nachteil dieser Methode ist aber, dass die einzelnen Peaks sehr lange Migrationszeiten haben (bis über 10 Minuten) und somit Verunreinigungen überdeckt werden können. Außerdem sind viele Bestandteile nicht von den Hauptkomponenten abgetrennt. Weiterhin ist diese Methode nicht sehr robust, da der Detektor sehr empfindlich ist. Eigene HPLC-Messungen an mehreren Gentamicin-Chargen zeigten die Probleme auf. Da Gentamicin kein chromophores System hat, kann es nicht mit einem UV/VIS-Detektor detektiert werden. Um dies dennoch zu ermöglichen, kann Gentamicin mit verschiedenen Reagenzien derivatisiert werden. In der vorliegenden Arbeit wurden alle Aminoglykoside mit ortho-Phthaldialdehyd und 2-Mercaptoessigsäure derivatisiert. Somit war eine Detektion bei 330 nm bzw. 340 nm möglich. Zur Trennung von Gentamicinsulfat wurde eine spezielle kapillarelektrophoretische Methode entwickelt. Die mizellare elektrokinetische Chromatographie (MEKC) ist nach Derivatisierung in der Lage, nahezu alle in der Monographie beschriebenen aber auch einige nicht aufgeführte Verunreinigungen zu trennen. Die Trennung erfolgt in einer Kieselgelkapillare mit einer Gesamtlänge von 33.0 cm, einer effektiven Länge von 24.5 cm und einem Innendurchmesser von 50 µm. Als Hintergrundelektrolyt wird ein Natriumtetraborat-Puffer verwendet (100 mM, pH 10.0), zu dem Desoxycholsäure-Natrium als mizellbildendes Reagenz in einer Konzentration von 20 mM und weiterhin beta-Cyclodextrin in einer Konzentration von 15 mM zugegeben wird. Die Proben werden hydrodynamisch bei 5000 Pa innerhalb 5 Sekunden auf der Anodenseite injiziert. Die Trennung erfolgt bei einer Kapillartemperatur von 25 °C und einer Trennspannung von +12 kV. Pikrinsäure wird als Interner Standard benutzt. Die Detektion erfolgt UV-spektroskopisch bei 340 nm. Die Hauptpeaks konnten durch „spiken“ mit den Einzelkomponenten, die u.a. säulenchromatographisch gewonnen wurden, identifiziert werden. Die vier Hauptkomponenten Gentamicin-C1, C1a, C2 und C2a sind basisliniengetrennt ebenso wie Gentamicin-C2b, die Verunreinigungen Garamin, Desoxystreptamin und Sisomicin. Bei den Untersuchungen von über 40 Gentamicin-Chargen verschiedener Hersteller und Händler fielen sowohl deutliche Unterschiede bezüglich der einzelnen Gehalte der Hauptkomponenten auf, als auch verschiedene Grade der Verunreinigungen. Anhand der Menge der Verunreinigungen konnten die Chargen in verschiedene Gruppen eingeteilt werden. Die Verunreinigung Sisomicin kann als Leitsubstanz der Verunreinigungen bezeichnet werden, da bei allen stärker verunreinigten Chargen Sisomicin in beträchtlichen Mengen vorhanden ist. Unter den untersuchten Proben befanden sich auch die Proben, die in den USA die eingangs erwähnten Todesfälle verursacht haben. Diese Proben konnten der Gruppe der stärker verunreinigten Gentamicin-Chargen eindeutig zugewiesen werden. Die Richtigkeit aller Messungen wurde durch 1H-NMR-Messungen bestätigt. Die Anwendbarkeit der entwickelten MEKC-Methode wurde auch an weiteren Aminoglykosiden untersucht. Die Methode ist ohne Änderung auf Sisomicin übertragbar. Der Sisomicin-Peak ist deutlich abgetrennt vom OPA-Reagenzpeak. Selbst kleine Verunreinigungen der CRS-Substanz können mit dieser Methode erkannt werden. Netilmicin und Amikacin können nicht ohne Änderungen mit der Methode vermessen werden, da sie unter diesen Bedingungen mit dem OPA-Peak komigrieren. Eine Anhebung der Trennspannung von +12 kV auf +14 kV lassen die Peaks hervortreten. Eine Unterscheidung der beiden Substanzen ist im Elektropherogramm nicht möglich, allerdings können sie durch 1H-NMR-spektroskopische Messungen identifiziert und unterschieden werden. Netilmicin wurde in vielen Gentamicin-Proben nachgewiesen. Bei Kanamycin liegen mit dieser Methode im Elektropherogramm sehr viele kleine Peaks sehr nahe beieinander. Durch Absenkung der Kapillartemperatur auf 20 °C können diese Peaks etwas besser getrennt werden... / The aim of this study was to separate gentamicin sulfate into its major and minor components by means of capillary electrophoresis. In May 2000 the death of 17 people and 60 people, respectively, was reported, following the administration of the commonly used broad spectrum antibiotic gentamicin sulfate. In addition hundreds of patients suffering from severe side effects were reported. Since this could not be explained by the pharmacological and toxicological properties of gentamicin, it was assumed that the side effects were related to impurities. Due to the fact that gentamicin is a fermentation product of Micromonospora purpurea, minor variations in the fermentation procedure may cause products, that cannot be detected by the analytical methods applied thus far. The current European Pharmacopoeia limits for related substance of gentamicin by means of an HPLC-method in combination with a pulsed amperometric detector. The advantage of this method is the fact, that it is not necessary to derivatize gentamicin. However, a major disadvantage of the method is the broadness of the main peaks (>10 minutes/peak). Hence, minor products could be covered by the main peaks. Furthermore, various peaks are not baseline separated and the method is not very robust owing to the highly sensitive detector. Due to the lack of a chromophore, gentamicin needs to be derivatized to allow detection by means of an UV-detector. In this study all aminoglycosides were labeled with orthophthaldialdehyde (OPA) in combination with 2-mercaptoacetic acid, which enabled detection at a wavelength of 340 nm. To separate gentamicin as OPA derivative, a method based on micellar electrokinetic chromatography (MEKC) was developed. This technique makes it possible to separate most of the impurities specified in the gentamicin monograph (garamine, deoxystreptamine, and sisomicin) and some additional, not further specified impurities such as paromamine and unknown products. The separation is carried out in a fused-silica capillary with a total length of 33.0 cm, an effective length of 24.5 cm and an inner diameter of 50 µm. Using sodium tetraborate buffer (100 mM, pH 10.0) as background electrolyte (BGE), deoxycholic acid sodium in a concentration of 20 mM as micelle forming agent and beta-cyclodextrin in a concentration of 15 mM are added. The samples are loaded hydrodynamically at 5000 Pa for 5 seconds on the anode side of the capillary and the separation is carried out at +12 kV and 25 °C. Picric acid is used as an internal standard and UV-detection is performed at 340 nm. Spiking experiments were performed using reference substances, obtained by column chromatography and commercially purchased reference substances for the impurities. The four major components gentamicin C1, C1a, C2, and C2a as well as the minor component C2b and the impurities garamine, deoxystreptamine, and sisomicin are baseline separated. Over 40 gentamicin batches of different pharmaceutical companies and producers were analyzed with respect to the content of the major components as well as the amount of the impurities. Varying levels of the major compounds as well as the impurities were identified, which allowed the grouping of the samples. All samples exhibiting a high amount of impurities were found to a high sisomicin concentration. Hence, sisomicin can be referred to as an impurity indicator. Some of the batches under scrutiny were responsible for the deaths found in the US. All these samples could be unambiguously assigned to the group which is characterized by a high number and a relatively high quantity of most unspecified impurities. All CE-measurements were verified by 1H NMR measurements. To investigate the applicability of the developed MEKC method, other aminoglycosides were also investigated. For sisomicin the standard method can be used without modification, since the sisomicin peak is separated from the OPA reagent peak and even small amounts of impurities of the CRS-substance can be detected with this method. For netilmicin and amikacin the developed method has to be modified. Under standard conditions the peaks of both substances co-migrates with the OPA reagent peak. Raising the voltage from +12 kV to +14 kV both peaks are separated. All Gentamicin samples were measured again using these new conditions. Netilmicin was often found in gentamicin samples. However, for these new conditions the migration time of netilmicin and amikacin are similar. Hence, they cannot be differentiated from each other in the same sample. Nevertheless, this differentiation can be carried out with 1H NMR measurements. Kanamycin samples show many peaks in a small zone of the electropherogram using the MEKC standard method. A slightly better separation can be obtained by using a lower temperature of the capillary of 20 °C instead of 25 °C...
26

Hyphenated mass spectrometric methods for quantitative metabolomics in E. coli and human cells

Timischl, Birgit January 2008 (has links)
Regensburg, Univ., Diss., 2008
27

Quantitative Analyse der MEN 1 Genexpression in peripherem Blut: Implikationen für die klinische Gendiagnostik

Reiser, Philipp, January 2006 (has links)
Ulm, Univ., Diss., 2006.
28

Development of techniques for the quantification of DNA from genetically modified organisms in processed foods

Moreano Guerra, Francisco Xavier. Unknown Date (has links)
Techn. University, Diss., 2005--München.
29

Untersuchungen der Elementgehalte luftgetragener Stäube mittels energiedispersiver Röntgenfluoreszenzspektrometrie

Schäfer, Clemens. Unknown Date (has links) (PDF)
Universiẗat, Diss., 1999--Hamburg.
30

Maßnahmen zur Verbesserung der Produktion von rekombinanten Proteinen und Plasmid-DNS

Friehs, Karl Hans. Unknown Date (has links)
Universiẗat, Habil.-Schr., 1999--Bielefeld.

Page generated in 0.2312 seconds