• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Angiovision - Pose d'endoprothèse aortique par angionavigation augmentée

Mouktadiri, Ghizlane 14 June 2013 (has links) (PDF)
Nous avons développé un modèle numérique du traitement des anévrismes de l'aorte abdominale (AAA) en utilisant l'analyse par éléments finis (FEA). L'objectif est de simuler les différentes étapes de la procédure endovasculaire dans la phase préopératoire. Pour cela, dans un premier temps, on a fait des études expérimentales Macro et Nano de rupture, indentation, traction, frottement des outils métalliques et des biomatériaux. Ensuite, on a développé une nouvelle approche de la conception des structures anatomiques très angulées et hétérogènes, et enfin, on a crée une maquette numérique de l'interaction outils métalliques et biomatériaux. Dans ce modèle, nous avons pris en compte la géométrie réelle reconstituée à partir des scans, une caractérisation locale des propriétés mécaniques guide / cathéter, une cartographie des propriétés des matériaux composites en fonction de la qualité pariétale, et une projection de l'environnement de l'artère dans l'outil de simulation. Nos résultats ont été validés grâce à un recalage entre les données cliniques et notre simulation pour un groupe donné de patients, dont les artères sont très tortueuses et calcifiées. Cet outil d'aide à l'acte chirurgical permet de contrôler avec précision la navigation endovasculaire en péropératoire, prédire la faisabilité de la chirurgie avec une fiabilité ainsi que d'optimiser le nombre d'outils métalliques pour chaque patient, en tenant compte du risque de rupture des zones avec fortes tortuosités et hétérogénéités.
2

Abdominal aortic aneurysm follow-up after endovascular repair in a canine model with non-invasive vascular elastography

Salloum, Elie 11 1900 (has links)
Le traitement chirurgical des anévrismes de l'aorte abdominale est de plus en plus remplacé par la réparation endovasculaire de l’anévrisme (« endovascular aneurysm repair », EVAR) en utilisant des endoprothèses (« stent-grafts », SGs). Cependant, l'efficacité de cette approche moins invasive est compromise par l'incidence de l'écoulement persistant dans l'anévrisme, appelé endofuites menant à une rupture d'anévrisme si elle n'est pas détectée. Par conséquent, une surveillance de longue durée par tomodensitométrie sur une base annuelle est nécessaire ce qui augmente le coût de la procédure EVAR, exposant le patient à un rayonnement ionisants et un agent de contraste néphrotoxique. Le mécanisme de rupture d'anévrisme secondaire à l'endofuite est lié à une pression du sac de l'anévrisme proche de la pression systémique. Il existe une relation entre la contraction ou l'expansion du sac et la pressurisation du sac. La pressurisation résiduelle de l'anévrisme aortique abdominale va induire une pulsation et une circulation sanguine à l'intérieur du sac empêchant ainsi la thrombose du sac et la guérison de l'anévrisme. L'élastographie vasculaire non-invasive (« non-invasive vascular elastography », NIVE) utilisant le « Lagrangian Speckle Model Estimator » (LSME) peut devenir une technique d'imagerie complémentaire pour le suivi des anévrismes après réparation endovasculaire. NIVE a la capacité de fournir des informations importantes sur l'organisation d'un thrombus dans le sac de l'anévrisme et sur la détection des endofuites. La caractérisation de l'organisation d'un thrombus n'a pas été possible dans une étude NIVE précédente. Une limitation de cette étude était l'absence d'examen tomodensitométrique comme étalon-or pour le diagnostic d'endofuites. Nous avons cherché à appliquer et optimiser la technique NIVE pour le suivi des anévrismes de l'aorte abdominale (AAA) après EVAR avec endoprothèse dans un modèle canin dans le but de détecter et caractériser les endofuites et l'organisation du thrombus. Des SGs ont été implantés dans un groupe de 18 chiens avec un anévrisme créé dans l'aorte abdominale. Des endofuites de type I ont été créés dans 4 anévrismes, de type II dans 13 anévrismes tandis qu’un anévrisme n’avait aucune endofuite. L'échographie Doppler (« Doppler ultrasound », DUS) et les examens NIVE ont été réalisés avant puis à 1 semaine, 1 mois, 3 mois et 6 mois après l’EVAR. Une angiographie, une tomodensitométrie et des coupes macroscopiques ont été réalisées au moment du sacrifice. Les valeurs de contrainte ont été calculées en utilisant l`algorithme LSME. Les régions d'endofuite, de thrombus frais (non organisé) et de thrombus solide (organisé) ont été identifiées et segmentées en comparant les résultats de la tomodensitométrie et de l’étude macroscopique. Les valeurs de contrainte dans les zones avec endofuite, thrombus frais et organisé ont été comparées. Les valeurs de contrainte étaient significativement différentes entre les zones d'endofuites, les zones de thrombus frais ou organisé et entre les zones de thrombus frais et organisé. Toutes les endofuites ont été clairement caractérisées par les examens d'élastographie. Aucune corrélation n'a été trouvée entre les valeurs de contrainte et le type d'endofuite, la pression de sac, la taille des endofuites et la taille de l'anévrisme. / Surgical treatment of abdominal aortic aneurysms is increasingly being replaced by EVAR using SGs. However, the efficacy of this less invasive approach is jeopardized by the incidence of persistent flow within the aneurysm, called endoleaks leading to aneurysm rupture if not properly detected. Hence, a life-long surveillance by computed tomography (CT) angiography on an annual basis is increasing the cost of EVAR, exposing the patient to ionizing radiation and nephrotoxic contrast agent. The mechanism of aneurysm rupture secondary to endoleak is related to a pressurization of the aneurysm sac close to the systemic pressure. There is a relation between sac shrinkage or expansion and sac pressurization. The residual pressurization of AAA will induce sac pulsatility and blood circulation in the sac thus preventing sac thrombosis and aneurysm healing. NIVE using the LSME may become a complementary follow-up imaging technique for EVAR. NIVE has the capability of providing important information on the thrombus organization within the aneurysm sac and on the detection of endoleaks. The characterization of the thrombus organization was not possible in a previous NIVE study. A limitation was the absence of CT examinations as gold standard for endoleak diagnosis. In the current study, we aimed to apply and optimize NIVE of AAA after EVAR with SG in a canine model to detect endoleaks and characterize thrombus organization. SGs were implanted in a group of 18 dogs with an aneurysm created in the abdominal aorta. Type I endoleak was created in 4 aneurysms, type II in 13 aneurysms and no endoleak in 1 aneurysm. DUS and NIVE examinations were performed at baseline, 1-week, 1-month, 3-month and 6-month follow-up after EVAR. Angiography, CT-scan and macroscopic tissue slides were performed at sacrifice. Strain values were computed using the LSME. Areas of endoleak, solid thrombus (organized) and fresh thrombus (non-organized) were identified and segmented by comparing the results of CT scan and macroscopic tissue slides. Strain values in areas with endoleak, organized and fresh thrombi were compared. Strain values were significantly different between endoleak and organized or fresh thrombus areas and between organized and fresh thrombus areas. All endoleaks were clearly characterized on elastography examinations. No correlation was found between strain values and type of endoleak, sac pressure, endoleak size and aneurysm size.
3

Angiovision - Pose d'endoprothèse aortique par angionavigation augmentée / Angiovision - Installation of aortic stent increased by angionavigation

Mouktadiri, Ghizlane 14 June 2013 (has links)
Nous avons développé un modèle numérique du traitement des anévrismes de l'aorte abdominale (AAA) en utilisant l'analyse par éléments finis (FEA). L'objectif est de simuler les différentes étapes de la procédure endovasculaire dans la phase préopératoire. Pour cela, dans un premier temps, on a fait des études expérimentales Macro et Nano de rupture, indentation, traction, frottement des outils métalliques et des biomatériaux. Ensuite, on a développé une nouvelle approche de la conception des structures anatomiques très angulées et hétérogènes, et enfin, on a crée une maquette numérique de l’interaction outils métalliques et biomatériaux. Dans ce modèle, nous avons pris en compte la géométrie réelle reconstituée à partir des scans, une caractérisation locale des propriétés mécaniques guide / cathéter, une cartographie des propriétés des matériaux composites en fonction de la qualité pariétale, et une projection de l'environnement de l’artère dans l’outil de simulation. Nos résultats ont été validés grâce à un recalage entre les données cliniques et notre simulation pour un groupe donné de patients, dont les artères sont très tortueuses et calcifiées. Cet outil d’aide à l’acte chirurgical permet de contrôler avec précision la navigation endovasculaire en péropératoire, prédire la faisabilité de la chirurgie avec une fiabilité ainsi que d’optimiser le nombre d’outils métalliques pour chaque patient, en tenant compte du risque de rupture des zones avec fortes tortuosités et hétérogénéités. / We have developed a numerical model of the treatment of abdominal aortic aneurysms (AAA) using finite element analysis (FEA) to simulate the endovascular procedure in the preoperative phase. The goal is to simulate different stages of the endovascular procedure. In the model, we took into account the geometry of the biological region reconstructed from scans, a local characterization of the guidewire/catheter mechanical properties, a mapping of material properties depending on the degree of calcification, and a projection of the aorta environment . Our results were validated based on a tuning between clinical data and our simulation for a given group of patients with very tortuous and calcified arteries. It allows to control with accuracy the delivery system rise during surgery, predict the feasibility of the surgery with reliability as well as choose the best guide for each patient, taking into account the risk of rupture of calcified areas in the case of high angulations.
4

Suivi par élastographie ultrasonore après réparation endovasculaire d’anévrisme aorto-iliaque : étude de faisabilité in vivo

Bertrand-Grenier, Antony 12 1900 (has links)
No description available.