• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 3
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Enjeux de la qualité microbiologique de l'eau à l'hôpital : impact sur les colonisations et infections nosocomiales à pseudomonas aeruginosa / Issues of hospital microbiological water quality

Lefebvre, Annick 02 September 2016 (has links)
La littérature fait suspecter mais n’indique pas clairement un lien entre la contamination du réseau d’eau et les infections nosocomiales à Pseudomonas aeruginosa. Les recommandations de prélèvements d’eau sont différentes selon les pays. Notre travail s’appuie sur les données des résultats des prélèvements d’eau et des prélèvements positifs à P. aeruginosa chez les patients (colonisation ou infections nosocomiales), réalisés au CHU de Dijon entre 2005 et 2013. Les contaminations des points d’eau étaient fréquentes (17%, IC95% 15,5-18,2). Des modèles mixtes n’ont pas montré de diminution d’incidence des cas de P. aeruginosa dans le nouveau bâtiment, moins souvent contaminé, pour les unités qui ont déménagé d’un bâtiment à un autre. La méthode de Kulldorff a permis de détecter peu d’agrégats temporels de cas. Des modèles GEE (Generalized Estimated Equations) ont montré une association positive entre la proportion de prélèvements d’eau positifs dans le trimestre dans le bâtiment et l’incidence des cas nosocomiaux. Cette association était retrouvée dans les analyses en sous-groupe des données de réanimation mais ne l’était plus lorsque les unités de réanimation et d’hématologie étaient exclues.Peu d’arguments en faveur d’un rôle du réseau d’eau dans la survenue de cas de P. aeruginosa sont apportés, en dehors des services de réanimation ou d’hématologie. En raison du coût associé aux prélèvements et aux mesures correctrices, il pourrait être proposé de limiter les prélèvements à ces unités à risque. Des études prospectives génotypiques devraient être conduites afin de mieux explorer l’association entre qualité microbiologique de l’eau à l’hôpital et infections nosocomiales. / Scientific literature allows suspecting but does not clearly indicate a link between water network contamination and Pseudomonas aeruginosa healthcare-associated infections. Guidelines for water samples vary across countries.Our work is based on water samples and P. aeruginosa patients’ samples (healthcare-associated colonizations or infections) in Dijon University hospital between 2005 and 2013.Water outlets contaminations were frequent (17%, CI95% 15.5-18.2). Mixed models on units that moved from a building to another did not show a lower incidence of P. aeruginosa cases in the new building than in the others, although it was less contaminated. Kulldorff’s method allowed detecting few temporal clusters of cases. GEE (Generalized Estimated Equations) models showed a positive association between the proportions of positive water samples in the building in the quarter and the incidence of healthcare-associated cases. This association was still observed in subgroup analyses of intensive care units but was no more observed in the database excluding hematology and intensive care units. Few arguments for an association between water network contamination and P. aeruginosa healthcare-associated colonizations or infections are provided, except in hematology and intensive care units. Given the costs associated with the samples and correctives measures, it could be proposed to limit the samples to these units at risk. Prospective studies with molecular typing methods should be conducted in order to better understand the association between hospital water network microbiologic quality and healthcare-associated infections.
2

Quasi real-time model for security of water distribution network / Modèle quasi-temps réel pour la sécurité des réseaux d’alimentation en eau potable

Ung, Hervé 05 February 2016 (has links)
Le but de cette thèse est de modéliser la propagation d’un contaminant au sein d’un réseau d’eau potable muni de capteurs temps réel. Elle comporte les trois axes de développement suivant: la résolution des équations de transport, celle du problème d’identification des sources de contamination et le placement des capteurs.Le transport d’un produit chimique est modélisé dans un réseau d’eau potable par l’équation de transport réaction 1-D avec l’hypothèse de mélange parfait aux noeuds. Il est proposé d’améliorer sa prédiction par l’ajout d’un modèle de mélange imparfait aux jonctions double T et d’un modèle de dispersion prenant en compte un profil de vitesse 3-D et la diffusion radiale. Le premier modèle est créé à l’aide d’un plan d’expériences avec triangulation de Delaunay, de simulations CFD, et de la méthode d’interpolation krigeage. Le second utilise les équations adjointes du problème de transport avec l’ajout de particules évoluant à l’aide d’une marche aléatoire, cette dernière modélisant la diffusion radiale dans la surface droite du tuyau.Le problème d’identification des sources consiste, à l’aide de réponses positives ou négatives à la contamination des noeuds capteurs, à trouver l’origine, le temps d’injection et la durée de la contamination. La résolution de ce problème inverse est faite par la résolution des équations de transport adjointes par formulation backtracking. La méthode donne la liste des sources potentielles ainsi que le classement de celles-ci selon leur probabilité d’être la vraie source de contamination. Elle s’exprime en fonction de combien, en pourcentage, cette source potentielle peut expliquer les réponses positives aux capteurs.Le placement des capteurs est optimisé pour l’identification des sources. L’objectif est la maximisation du potentiel de détection de la véritable source de contamination. Deux résolutions sont testées. La première utilise un algorithme glouton combiné à une méthode de Monte Carlo.La seconde utilise une méthode de recherche locale sur graphe.Finalement les méthodes sont appliquées à un cas test réel avec dans l’ordre : le placement des capteurs, l’identification de la source de contamination et l’estimation de sa propagation. / The aim of this thesis is to model the propagation of a contaminant inside a water distribution network equipped with real time sensors. There are three research directions: the solving of the transport equations, the source identification and the sensor placement. Classical model for transport of a chemical product in a water distribution network isusing 1D-advection-reaction equations with the hypothesis of perfect mixing at junctions. It isproposed to improve the predictions by adding a model of imperfect mixing at double T-junctions and by considering dispersion effect in pipes which takes into account a 3-D velocity profile. The first enhancement is created with the help of a design of experiment based on the Delaunay triangulation, CFD simulations and the interpolation method Kriging. The second one uses the adjoint formulation of the transport equations applied with an algorithm of particle backtracking and a random walk, which models the radial diffusion in the cross-section of a pipe.The source identification problem consists in finding the contamination origin, itsinjection time and its duration from positive and negative responses given by the sensors. The solution to this inverse problem is computed by solving the adjoint transport equations with a backtracking formulation. The method gives a list of potential sources and the ranking of thosemore likely to be the real sources of contamination. It is function of how much, in percentage, they can explain the positive responses of the sensors.The sensor placement is chosen in order to maximize the ranking of the real source of contamination among the potential sources. Two solutions are proposed. The first one uses agreedy algorithm combined with a Monte Carlo method. The second one uses a local search method on graphs. Finally the methods are applied to a real test case in the following order: the sensor placement, the source identification and the estimation of the contamination propagation.
3

Caractérisation et impact de la pollution dans les rejets urbains par temps de pluie (RUTP) sur des bassins versants de l'agglomération Orléanaise. / Characteristics and impact of urban runoff pollution on subwatersheds of the Orléans agglomeration

Al-Juhaishi, Mohammed 25 June 2018 (has links)
L’objectif de cette thèse est de caractériser les Rejets Urbains par Temps de Pluie (RUTP) et leur flux au niveau des exutoires d’eaux pluviales de trois sous-bassins majeurs de l'agglomération orléanaise. Pour cela des prélèvements ponctuels d’eau ont été effectués et un modèle conceptuel a été utilisé. Les trois sous-bassins : La Corne (463 ha), l'Egoutier (2080 ha) et Ormes (2256 ha) ont des occupations du sol différentes.D’une manière générale, la conductivité, la demande chimique en oxygène (DCO), la demande biochimique en oxygène (DBO5 et la DBO28), le carbone organique dissout (COD), l'azote total(NT), et les concentrations en anions et cations majeurs étaient plus élevés par temps sec que par temps de pluie indiquant un effet de dilution par les précipitations. Il a été mis en évidence un mélange des eaux pluviales avec des eaux usées dans le sous bassin d’Ormes. L’occupation des sols et les activités anthropiques influencent de manière significative la qualité du ruissellement. Par exemple, dans le sous-bassin de l’Egoutier, la présence d’une zone imperméable (industries et habitations) importante (40% de la surface) est responsable d’une augmentation des paramètresDBO5, DBO28, COD et NT.Les flux aux exutoires des différents paramètres de qualité de l’eau ont été évalués et comparés à ceux issus des quatre principales stations d’épuration (STEP) et à ceux de la Loire. La charge destrois sous-bassins urbains représente environ 166,61% de la charge des quatre STEP. Les trois sous bassins ont un faible impact sur la Loire en termes de flux annuels (environ 1,62% pour les MES par temps de pluie).Deux versions d’un modèle conceptuel dit d'accumulation/lavage-transport ont été évaluées pour estimer les flux de ruissellement des polluants ; la version classique et une version modifiée dans laquelle le paramètre accumulation des polluants a une forme logarithmique. Les performances des modèles étaient acceptables pour les MES et la DCO. Les coefficients de corrélation étaient supérieurs à 90% pour le sous bassin de l’Egoutier, par exemple. Pour les éléments traces métalliques en phase particulaire, la corrélation avec l’expérience était bonne également. D’une manière générale, lorsqu'un flux mesuré était inférieur à 1 kg.ha-1, les modèles n’étaient plus applicables.Des premiers essais de simulation de la qualité et la quantité de RUTP ont été effectués à partir de MIKE URBAN, qui équipe les deux logiciels de modélisation MOUSE et SWMM. Les hydrogrammes ont indiqué que le débit maximum obtenu avec SWMM était toujours inférieur à celui obtenu avec MOUSE. La qualité de l’eau (masse de MES) était toujours plus fortement impactée par le lessivage des MES dans le modèle MOUSE que dans SWMM.Ce travail constitue la première étape du travail d'évaluation de RUTP pour l'Agglomération orléanaise. Il constitue une base solide pour un futur programme de surveillance continue. / The objective of this thesis was to characterize urban runoff water at the level of stormwater outletson three major urban sub-basins of the Orléans agglomeration, covering land areas ranging in size from463 to 2257 ha and with contrasted land use. 11 individual rain events were sampled at runoff outletsbetween April 2015 and June 2017 and 10 campaigns were also carried out in dry weather.In general, it was observed that the conductivity, chemical oxygen demand (COD), biochemicaloxygen demand (BOD5 and BOD28), dissolved organic carbon (DOC), total nitrogen (NT), anions andmajor cations were found to be higher in dry weather conditions than in rainy weather. These resultsindicate a dilution effect due to precipitation.A mixture of rainwater and wastewater was also identified in the sub-basin of Ormes. Land use andhuman activities in the sub-basin studied were found to significantly influence the quality of the resultedrunoff from rainfall events. For example, in the Egouttier sub-basin 2, the presence of a large imperviouszone (industrial and residential, 40% of the surface area) was responsible for an increase in the parametersBOD5, BOD28, COD and NT.The flows at the outlets of the different water quality parameters were evaluated and compared withthose from the four main wastewater treatment plants (WWTP) and those from the Loire. The estimatedloads of the three sub-urban basins accounts for approximately 166.61% of the load of the four WWTP.The three sub-basins have a small impact on the Loire in terms of annual flows (about 1.62% for wetweather case).Two versions of a conceptual model of accumulation / washoff were evaluated to estimate pollutantrunoff; the classical version and a modified version in which the pollutant accumulation parameter has alogarithmic form. The performances of the models were found acceptable for the MES and the COD. TheNash-Sutcliffe (NS) coefficients were found as 0.84 and 0.85 for the two versions at the Egouttier subbasin.For trace elements in particulate phase, the correlation with the experimental measured value wasfound good as well. In general, when a measured flow was less than 1 kg.ha-1, the modified model was nolonger applicable.The first simulation tests of the quality and quantity of urban runoff were carried out with MIKEURBAN, which equips both MOUSE and SWMM modeling software. For water quantity, the hydrographsindicated that the maximum flow obtained with SWMM was always lower than that obtained with MOUSE.For water quality, TSS mass was still more strongly impacted by the leaching of TSS in the MOUSE modelthan in the SWMM model.This work can be considered as the first step of the evaluation work of RUTP for the Orléansagglomeration. It provides a solid foundation for a future monitoring program.

Page generated in 0.0409 seconds