• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 59
  • Tagged with
  • 59
  • 59
  • 31
  • 13
  • 12
  • 10
  • 10
  • 9
  • 9
  • 8
  • 6
  • 6
  • 5
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Comparação da acurácia entre tomografia computadorizada de feixe cônico e radiografia digital no diagnóstico de reabsorções cervicais invasivas simuladas

Sá, Saione Cruz January 2011 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2012-10-26T08:11:03Z (GMT). No. of bitstreams: 1 301798.pdf: 1780277 bytes, checksum: bc2f2a58c2e7d58841be5a65876c37e2 (MD5) / O estudo comparou acurácia entre tomografia computadorizada de feixe cônico (TCFC) e radiografia digital (RD) no diagnóstico de reabsorções cervicais invasivas (RCI) simuladas com diferentes extensões. Cem molares humanos divididos em 4 grupos experimentais (RCI1, RCI2, RCI3 e RCI4) e um controle (RCI0) foram posicionados em um crânio humano seco. Nos dentes dos grupos experimentais foram simuladas RCI classes 1, 2, 3 e 4. O número de cada grupo foi representado pelo da classificação das RCI, que foi dado de acordo com a extensão da lesão. Em seguida, imagens radiográficas e tomográficas foram obtidas e um examinador calibrado as avaliou por meio dos softwares nativos de ambos os equipamentos. A concordância intraobservador foi alta para ambos os exames diagnósticos, com 100% de concordância para presença de RCI, RCI 1 e 2, quando a TCFC foi empregada. Os valores de sensibilidade, especificidade, VPP e VPN foram mais altos para todos os grupos na observação das imagens por TCFC. A TCFC apresentou 100% de acurácia na detecção da presença de RCI e maior acurácia que a RD no diagnóstico de todos os grupos. A RD apresentou resultados estatisticamente equivalentes à TCFC (p>0,05) para detecção das classes de RCI, entretanto, para detecção da presença de RCI, a TCFC apresentou melhor desempenho, sendo estatisticamente significante (p<0,05). Portanto, concluiu-se que apesar da TCFC e RD apresentarem-se equivalentes para detecção das classes de RCI, a TCFC apresentou maior acurácia no diagnóstico da presença de RCI e no diagnóstico de lesões de RCI simuladas em diferentes-extensões.
22

AVALIAÇÃO DA REPRODUTIBILIDADE DE PONTOS CEFALOMÉTRICOS NAS TELERRADIOGRAFIAS DIGITAIS EM NORMA LATERAL NOS FORMATOS DICOM, TIFF E JPEG / Evaluation the reproducibility of cephalometric landmarks on digital lateral headfilms at the file formats DICOM, TIFF and JPEG

Falcão, Livia Maria Rocha 26 March 2009 (has links)
Made available in DSpace on 2016-08-03T16:31:13Z (GMT). No. of bitstreams: 1 Livia Maria.pdf: 2258638 bytes, checksum: 3131cd2061c06afb853c81d96d50af92 (MD5) Previous issue date: 2009-03-26 / The digital radiography image acquired by the photostimulable storage phosphor plates system normally is showed in the computer screen as a DICOM format, characterized for the high resolution of the images. As this format uses a lot of memory space for storage, the digital images are submitted to a compression, which optimizes the capacity of space on the computers and reduces the time of transmission for the Internet. The aim of this study was to evaluate the effect of TIFF and JPEG compression in the intraobserver and interobserver reproducibility of the cephalometric landmarks identification on lateral headfilms compared with DICOM format. The sample consisted of 90 digital lateral cephalometric images obtained from 30 individuals, in DICOM format. These images were converted for formats JPEG, with Quality Factor 80 and TIFF. After blind and random the sample, three observers, orthodontists, were calibrated and ask to identify 15 cephalometric landmarks in each image using x and y coordinates system. The results had shown that the cephalometric landmarks identification had presented agreement of intraobserver and interobserver reproducibility, except for the points Go, Po, Or, B and Pog'. The statistic analyze showed no difference between the file formats for each point and axis. JPEG and TIFF compressions studied had not effect in the intraobserver and interobserver reproducibility of the cephalometric landmarks identification on digital lateral headfilm.(AU) / A imagem radiográfica digital adquirida pelo sistema de placa de fósforo foto ativada é normalmente visualizada no monitor do computador no formato DICOM, caracterizado pela alta resolução das imagens. Como este formato ocupa muito espaço para armazenamento, as imagens digitais são submetidas a uma compressão, que otimiza a capacidade de espaço dos computadores e reduz o tempo de transmissão pela Internet. O objetivo desse estudo foi avaliar a influência da compressão TIFF e JPEG na reprodutibilidade intra e interexaminador da marcação de pontos cefalométricos em imagens de telerradiografias em norma lateral comparadas com o formato DICOM. A amostra consistiu de 90 imagens de telerradiografias obtidas a partir de 30 indivíduos, dos quais se obteve uma radiografia digital exibida no formato DICOM. Estas imagens foram convertidas para os formatos JPEG, com Fator de Qualidade 80 e TIFF. Após o cegamento e randomização da amostra, três ortodontistas calibrados marcaram a localização de 15 pontos cefalométricos em cada imagem utilizando o sistema de coordenadas x e y. Os resultados mostraram que as marcações dos pontos cefalométricos apresentaram concordância de reprodutibilidade tanto intra como interexaminador, exceto para os pontos Go, Po, Or, B e Pog . Os diferentes formatos de arquivo mostraram resultados estatisticamente semelhantes para cada ponto e eixo aferido. As compressões JPEG e TIFF estudadas não tiveram efeito, em imagens de telerradiografias em norma lateral, na reprodutibilidade intra e interexaminadores da marcação dos pontos cefalométricos testados.(AU)
23

Avaliação da influência dos formatos DICOM e JPEG na reprodutibilidade de pontos cefalométricos em Telerradiografia digital em Norma Frontal / Evaluation of influence of DICOM and JPEG formats in the reproducibility of cephalometric landmarks in digital Frontal Teleradiographies

Saez, Daniel Martinez 31 March 2009 (has links)
Made available in DSpace on 2016-08-03T16:31:14Z (GMT). No. of bitstreams: 1 DANIEL MARTINEZ SAEZ.pdf: 1606570 bytes, checksum: c2773e8408583cb2ada8e4b43508558e (MD5) Previous issue date: 2009-03-31 / The digital image on DICOM format request a large store size capability, making difficult the transmission through internet, usually requesting the image compression via JPEG file format. The aim of this study was to evaluate the influence of DICOM and JPEG file formats on Quality Factors 100, 80 and 60, in the reproducibility intra and interexaminer at cephalometrics landmarks identification at digital Frontal Teleradiographies. The sample consists of 120 digital images of Frontal Teleradiographies, obtained from 30 individuals. The 30 original images in DICOM format was converted into a JPEG format on Quality Factors 100, 80 and 60. After blind and random the sample, three calibrated orthodontist marked 18 cephalometric points on each image using a computerized cephalometric program which has in account cephametric points values in a X and Y cartesians coordinates system. At the results, the statistical tests at intraclasses correlations and variant analysis (ANOVA) presents a reproducibility agreement of the cephalometric points on digital Frontal Teleradiographies on intra such as interexaminer, except for points ZL, ZR, AZ, JR, NC, CN on coordinate Y and A6 on coordinate X, independently of file formats. As a conclusion, the file formats DICOM and JPEG on Quality Factors 100, 80 and 60 do not affected the reproducibility intra and interexaminers on a cephalometric landmarks identification.(AU) / A imagem digital no formato DICOM requer grande espaço para armazenamento, dificultando o arquivamento e transmissão da imagem via internet, sendo necessária, muitas vezes, a compressão das imagens por meio de formatos de arquivo como o JPEG. O objetivo neste estudo foi avaliar a influência dos formatos DICOM e JPEG, nos Fatores de Qualidade 100, 80 e 60, na reprodutibilidade intra e interexaminador na marcação de pontos cefalométricos em Telerradiografias digitais em Norma Frontal. A amostra consistiu de 120 imagens digitais de Telerradiografias em Norma Frontal, obtidas de 30 indivíduos. As 30 imagens originais, em formato DICOM, posteriormente, foram convertidas para o formato JPEG, nos Fatores de Qualidade 100, 80 e 60. Após cegar e randomizar a amostra, três ortodontistas calibrados marcaram os 18 pontos cefalométricos em cada imagem utilizando um programa de cefalometria computadorizada, que registra as medidas dos pontos cefalométricos em um sistema de coordenadas cartesianas X e Y. Nos resultados, os testes estatísticos de correlações intraclasses e análise de variância (ANOVA) apresentaram concordância de reprodutibilidade dos pontos cefalométricos em Telerradiografias digitais em Norma Frontal, tanto intra como interexaminador, com exceção dos pontos ZL, ZR, AZ, JR, NC, CN na coordenada Y e A6 na coordenada X, independentemente dos formatos de arquivo. Em conclusão, os formatos de arquivo DICOM e JPEG, nos Fatores de Qualidade 100, 80 e 60, não afetaram a reprodutibilidade intra e interexaminador na marcação dos pontos cefalométricos.(AU)
24

Avaliação da reprodutibilidade da marcação de pontos cefalométricos na telerradiografia cefalométrica póstero-anterior digital nos formatos DICOM, JPEG e TIFF

Tassara, Luiz Felipe Rossi 15 April 2010 (has links)
Made available in DSpace on 2016-08-03T16:31:15Z (GMT). No. of bitstreams: 1 Luiz Felipe Rossi Tassara.pdf: 2423467 bytes, checksum: a93c786e4603fdb675dd48b24da6aefd (MD5) Previous issue date: 2010-04-15 / A terradiografia cetalométrica póstero-anterior digital está substituindo a telerradiografia convencional, porém permanece a dúvida se os erros de reprodutibilidade encontrados nas telerradiografias cefalométricas póstero-anteriores, também ocorreriam nas radiográfias digitais e se o formato de arquivo da imagem poderá influenciar na reprodutibilidade dos pontos cefalométricos. O objetivo deste estudo foi avaliar a reprodutibilidade da marcação de alguns pontos cefalométricas da análise cefalométrica de RICKETTS, em telerradiografias cefalométricas póstero-anteriores digitais, nos formatos DICOM, TIFF e JPEG. A amostra consistiu de 150 imagens digitais de terradiografias cefalométricas póstero-anteriores, obtidas a partir de 30 indivíduos, no formato DICOM; que foram convertidas para os formatos TIFF e JPEG nos fatores de qualidade 100, 80 e 60. Após o cegamento e randomização da amostra, três ortodontistas marcaram os pontos cefalométricos utilizando o sistema de coordenadas cartesianas, eixos x e y, no Programa Radiocef (Radio Memory) Para a análise estatística foram utilizados a Correlação Intraclasse, Fórmula de Dalhberg, Análise de Variância (ANOVA) e Análise de Comparações Multiplas de Bonferroni.(AU)
25

Método de desenvolvimento de reabsorções cervicais invasivas in vitro para estudos de imagens de radiografia digital e tomografia computadorizada de feixe cônico

Azevedo, Marco Antonio Diniz January 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2013-03-04T18:10:43Z (GMT). No. of bitstreams: 0 / Esta pesquisa desenvolveu um protocolo in vitro que simula reabsorções cervicais invasivas (RCIs) em dentes humanos, para diagnóstico por meio de radiografia digital e tomografia computadorizada de feixe cônico (TCFC). Dezesseis dentes humanos hígidos foram distribuídos em quatro grupos, RCI1; RCI2; RCI3; RCI4. Após a secção longitudinal dos dentes foram realizadas cavidades com profundidades, extensões e limites irregulares, reproduzindo as RCIs nas classes 1, 2, 3 e 4, descritas por Heithersay. Após a colagem dos segmentos longitudinais, os dentes foram avaliados por meio de radiografia periapical digital (RPD) e tomografia computadorizada de feixe cônico (TCFC). As imagens obtidas foram comparadas por três observadores com imagens de três casos clínicos de RCIs, incisivo central superior, canino superior e molar inferior. As imagens obtidas por meio de RPD foram semelhantes às descritas por Heithersay, assim como as de TCFC quando comparadas às imagens dos casos clínicos. As RCIs in vitro realizadas pelo método proposto são reprodutíveis e representam as mesmas características de imagem das RCIs em radiografias periapicais digitais e de tomografia computadorizada de feixe cônico. / This research developed a protocol that simulates invasive cervical resorption (ICR) in human teeth, diagnostic by periapical radiography and cone beam CT (CBCT), to be reproducible and applicable in studies evaluating diagnostic imaging methods such resorption. Sixteen healthy human teeth were divided into four groups. These teeth were sectioned along its long axis and irregular cavities were created with diamond FG reproducing the ICRs classes 1, 2, 3 and 4 proposed by Heithersay. After bonding of longitudinal segments, the teeth were evaluated by means of digital periapical radiography (DPR) and Cone Beam CT (CBCT). The images obtained were compared with images of some clinical cases of ICR. Images obtained by DR and CBCT were similar to those described by Heithersay, as well as images of clinical cases. The in vitro ICRs held by the proposed method are reproducible and represent the radiographic and tomographic features of these lesions.
26

Influência das variações de ângulos de projeção na detecção de reabsorções radiculares linguais e apicais simuladas: comparação entre subtração radiográfica digital e radiografia digital direta

Moraes, Michelle Bianchi de [UNESP] 05 August 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:09Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-08-05Bitstream added on 2014-06-13T18:46:28Z : No. of bitstreams: 1 moraes_mb_dr_sjc.pdf: 1197811 bytes, checksum: 257ea85b7a3e332fae697c54b7a1c2a9 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A reabsorção severa da raiz diagnosticada tardiamente pode acarretar a perda dentaria, e sendo a técnica de subtração radiográfica digital (SDR) um importante recurso para detecção precoce de alterações minerais, este estudo avaliou a eficiência no diagnóstico precoce da reabsorção radicular externa simulada apical e lingual, pela técnica de subtração radiográfica digital (SRD) e radiografia digital (RD). Foram utilizados 14 dentes incisivos de mandíbulas humanas maceradas com reabsorções de diferentes dimensões, simuladas na região apical e lingual, e radiografados com variação de ângulos de projeção. As radiografias foram subtraídas pelo programa Regeemy®, e para avaliação do desempenho dos métodos de diagnóstico, pares de radiografias periapicais e imagens subtraídas foram apresentadas a 2 radiologistas. De acordo com os resultados, não foram observadas diferenças estatisticamente significativas entre os métodos na detecção de reabsorções linguais, independentemente do tamanho da lesão, assim como não houve diferença entre os métodos na detecção de reabsorções apicais, com exceção do examinador 2 com relação a variação angular vertical e horizontal de 100 utilizando o maior nível de desgaste, que apresentou a radiografia digital como método superior na avaliação em relação a subtração radiográfica. E o aumento no nível de desgastes e a menor variação dos ângulos verticais e horizontais permitiram melhor avaliação nas regiões de reabsorções apicais e linguais, para detecção das reabsorções apicais e linguais. Com estes resultados podemos concluir que a subtração radiográfica digital é um exame indicado para detecção de pequenas perdas minerais em radiografias que apresentem pouca ou nenhuma variação nas angulações verticais e horizontais / The severe root resorption diagnosed late can lead to tooth loss, and being the technique of digital subtraction radiography (SDR) as an important resource for early detection mineral changes, this study evaluated the efficiency in the early diagnosis simulated external root resorption apical and lingual by the technique of digital subtraction radiography (SRD) and digital radiography (DR). We used 14 human incisors jaw macerated with resorption different sizes, simulated in the apical and lingual, and radiographed with a range of projection angles. The radiographs were subtracted by the program Regeemy ®, and performance evaluation diagnostic methods, pairs intraoral radiographs and subtracted images were presented to two radiologists. According to the results, there were no statistically significant differences between methods in the detection lingual resorption, regardless of lesion size, as there was no difference between the methods in the detection of apical resorption, except the second examiner with respect to variation vertical and horizontal angle of 100 using the highest level of wear, which lodged the digital radiography as a method superior in the evaluation for subtraction radiography. And the increase in the level of wear and less variation vertical and horizontal angles allowed a better assessment resorption in the regions apical and lingual to detect and lingual apical resorption. With these results we conclude that the digital subtraction radiography is a test for the detection of small mineral loss in radiographs showing little or no variation in vertical and horizontal angles
27

Influência dos remanescentes dentários e de resinas compostas nos níveis de cinza de dentes em radiografias digitais

Graziottin, Luiz Felipe Rodrigues January 2009 (has links)
Made available in DSpace on 2011-12-27T14:14:23Z (GMT). No. of bitstreams: 2 000409857-0.pdf: 3768332 bytes, checksum: 510f89bdc41453b63f0fecf44ffcf27c (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / This study investigates how, through digital radiography, the averages in gray levels are expressed in different sites of teeth restored with composite resins in varying thicknesses and what the possible reasons are for the values found. This study comprises a selection of ten healthy first premolars whose roots were embedded in prisms with rectangular bases, then radiographed according to standard procedure by using DenOptix digital optic plates, and whose were digitalized and filed for further analysis. Such samples formed group 1. Each time those teeth received some type of treatment which altered their original shape, a new group was formed. The teeth underwent a standard cavity preparation with a 2mm B-P thickness and were radiographed one more time. Their images were filed, thus forming group 2. The cavities were then restored with Filtek™Z350 composite resins and the teeth were radigraphed again and their digital images filed, thus forming group 3. Such restorations were then removed from their corresponding cavities and the teeth were restored one more time with 4Seasons resin, later radiographed, and their digital images were filed, thus forming group 4. After the restorations were removed, the cavities they once filled were restored with Filtek™Z250 resin. The radiography and filing steps were repeated one more time, thus forming group 5. After the restorations were removed, the cavities’ V-P widths were enlarged by 3mm, and the same steps applied to the previous groups were repeated, thus forming groups 6, 7, 8 and 9. After the removal of the restorations from group 9, the cavities’ V-P widths were enlarged by 4mm, and the same procedures applied to the previous groups were repeated, thus forming four new groups: 10, 11, 12 and 13.Thirty acrylic plates were also manufactured whose thicknesses varied between 2, 3 and 4mm, ten plates of each thickness – each plate contained one sample of each resin. The digital images of plates forming groups 14, 15 and 16 were subject to the same process of radiography and filing aforementioned. Samples of each composite resin were analyzed by EDS for verification of chemical elements responsible for these materials’ radiopacity traits. After the statistical analysis of the data rendered by these procedures, it was possible to conclude that: (1)There were significant differences between the readings sites. (2)The smallest averages in gray levels were found in the teeth with the largest preparations and without filings (G10 - 4mm). (3)The biggest averages in gray levels with the teeth restored with the 4Seasons® resin were found within the greatest restoration thickness (4mm - G12). (4)The teeth with cavities had lower averages in gray levels than the healthy dental tissues. (5)The restored teeth showed higher averages in gray levels than the healthy dental tissues, with the exception of the Filtek™Z350 Resin in the proximal sites of the 3mm restorations. (6)The restored teeth displayed higher averages in gray levels than the ones with cavity preparation but no filings. (7)There were different values for the averages in gray levels between the various composite resins studied when they were analyzed individually, without the interference of dental tissues (plates) and in the same thickness. (8)For the composite resins without the influence of dental tissues, the greater the thickness meant the higher the average in gray levels. (9)The values in gray levels for the restored teeth did not always change in accordance with the changes in gray levels for the composite resins individually analyzed (plates) in the corresponding thickness. (10)The higher concentration of chemical element with a higher atomic number translated into higher averages in gray levels for the composite resins. / Este trabalho teve como objetivo verificar, através da radiografia digital, como se expressam os valores médios, em níveis de cinza, em diferentes sítios de dentes restaurados com resinas compostas em diversas espessuras e quais as possíveis justificativas para tais valores encontrados. Para tanto foram selecionados 10 primeiros pré-molares hígidos, que tiveram suas raízes incluídas em prismas de base quadrangular, sendo radiografados por técnica padronizada utilizando placas ópticas do sistema digital DenOptix, as quais foram digitalizadas e arquivadas para posterior análise. Estas constituíram o grupo 1. Cada vez que estes dentes recebessem algum tratamento, que alterasse a sua forma original, se constituiria um novo grupo. Os dentes passaram por preparo cavitário padronizado com espessura V-P de 2mm, foram novamente radiografados e as imagens digitais arquivadas, constituindo o grupo 2. As cavidades foram restauradas com resina composta Filtek™Z350, os dentes foram novamente radiografados e as imagens digitais arquivadas, constituindo o grupo 3. Essas restaurações foram destacadas das cavidades e os dentes novamente restaurados com a resina 4Seasons, radiografados e as imagens digitais arquivadas, constituindo grupo 4. Após as restaurações serem destacadas, essas cavidades foram mais uma vez restauradas, agora com a resina Filtek™Z250, repetindo-se as radiografias e o arquivamento das imagens digitais, constituindo o grupo 5. Após a remoção dessas restaurações as cavidades foram ampliadas na largura V-P para 3mm, repetindo-se a mesma seqüência realizada nos grupos anteriores, constituindo os grupos 6, 7, 8 e 9. Após a remoção das restaurações do grupo 9, as cavidades foram ampliadas na largura V-P para 4mm, repetindo-se a seqüência realizada nos grupos anteriores, constituindo novos grupos: 10, 11, 12 e 13.Também foram confeccionadas 30 placas acrílicas nas espessuras de 2, 3 e 4mm, 10 placas em cada uma das espessuras, sendo que as placas continham uma amostra de cada resina. Estas constituíram os grupos 14, 15 e 16 que passaram pelo mesmo processo de radiografia e arquivamento das imagens digitais. Amostras de cada uma das resinas compostas foram analisadas pelo EDS, para verificação dos elementos químicos responsáveis pelas características de radiopacidade desses materiais. Após análise estatística dos dados foi possível concluir que: (1)existiu diferença significativa entre os sítios de leitura. (2)Encontraram-se os menores valores médios em níveis de cinza nos dentes com maiores preparos cavitários sem restaurações (G10 - 4mm). (3)Encontraram-se os maiores valores médios, em níveis de cinza, nos dentes restaurados com a resina 4 Seasons® na maior espessura de restauração (4mm - G12). (4)Os dentes cavitados apresentaram valores médios, em níveis de cinza, inferiores aos das estruturas dentárias hígidas. (5)Os dentes restaurados apresentaram valores médios, em níveis de cinza, superiores aos das estruturas dentárias hígidas, com exceção da resina Filtek™Z350 nos sítios proximais das restaurações na espessura de 3mm. (6)Os dentes restaurados apresentaram valores médios, em níveis de cinza, superiores aos dos dentes com preparos cavitários sem restaurações. (7)Houve distinção entre os valores médios, em níveis de cinza, para as diferentes resinas compostas estudadas quando analisadas individualmente, sem influência dos tecidos dentários (placas) em uma mesma espessura. (8)Para as resinas compostas sem a influência dos tecidos dentários, quanto maior foi a espessura, maior o valor médio em níveis de cinza.(9)Os valores em níveis de cinza para os dentes restaurados nem sempre alteraram-se conforme as alterações em níveis de cinza das resinas compostas analisadas individualmente (placas) na espessura correspondente. (10)A presença de maior concentração do elemento químico de mais alto número atômico refletiu-se em maiores valores médios, em níveis de cinza, nas resinas compostas.
28

Avaliação radiográfica da movimentação do segundo molar inferior após a exodontia do terceiro molar

Gabriel Fiorelli Bernini 25 March 2009 (has links)
Muitos pacientes submetidos à exodontia de terceiros molares relatam, no pósoperatório, que percebem alterações na oclusão. Por isso é interessante avaliar se realmente existe esta possível movimentação para distal dos segundos molares inferiores após a exodontia dos terceiros molares. Os objetivos deste trabalho foram analisar e verificar se existe variação da angulação do longo eixo do segundo molar em relação ao longo eixo do primeiro molar por meio de tomadas radiográficas periapicais digitais pelo sistema Digora®. A amostra constituiu-se de 20 pacientes entre 15 e 25 anos de idade que possuíam terceiros molares inferiores não irrompidos, bilateralmente, com indicação para extração e que se apresentavam de maneira simétrica com relação ao seu posicionamento. Os dentes foram extraídos, sendo um dos lados mantido apenas o coágulo (grupo controle) e o outro lado (grupo experimental) recebeu o enxerto do material proposto e membrana de cortical óssea bovina desmineralizada (Gen-derm). No Adobe Photoshop 7.0 foi possível realizar os traçados dos longos eixos dos primeiros e segundos molares inferiores e a intersecção entre eles. O programa ImageJ 1.41 foi responsável pela obtenção dos valores das angulações. Os exames foram realizados utilizando medidas em imagens obtidas no controle pós-operatório imediato, de 2, 6 e 24 meses nos dois grupos estudados. Os resultados mostraram que não houve diferença estatisticamente significante entre os grupos experimental e controle, e também não houve diferença ao longo do tempo, sugerindo que não existe movimentação para distal dos segundos molares inferiores após a extração dos terceiros molares e alterações na oclusão. Unitermos: Terceiro molar, Radiografia digital, Movimentação dentária. / Many patients submitted to the extraction of third molars, report, postoperatively, that they feel alterations in their occlusion. Thus, it is interesting to assess whether this possible movement to the distal of lower second molars, following the removal of third molars, really exists. This work aimed at analyzing and verifying, through digital periapical radiographies of the Digora® System, whether the angulation of the second molar´s long axis varies in relation to that of the first molar. The sample was comprised of 20 patients between 15 and 25 yrs, who presented non-erupted lower third molars, bilaterally, referred to extraction and in a symmetrical manner, in relation to their position. The teeth were extracted, being maintained, in one of the sides, only the clot (control group), while the other side (experimental group) received the graft of the proposed material and demineralized cortical bone bovine membrane (Gen-derm). In the Adobe Photoshop 7.0, it was possible to perform the outlining of the long axes of lower first and second molars and the intersection between them. The 1.41 ImageJ Program allowed the angulations values, and the exams were performed by utilizing measures in images obtained in the immediate postoperative control of 2, 6 and 24 months, in the groups studied. No statistically significant difference was seen between the experimental and control groups, as there was no difference as time passed, suggesting that there is no movement towards the distal of lower second molars, following the extraction of third molars and alterations in the occlusion.
29

"Validação das ferramentas de calibragem de medidas em três sistemas de radiografia digital" / Assessment of calibration tools of three digital radiography systems

José Raul Girondi 30 March 2006 (has links)
O desenvolvimento tecnológico busca fatores que possibilitem uma menor exposição do paciente e profissional aos raios ionizantes, maior agilidade no atendimento ao paciente e maior auxilio no desenvolvimento do diagnóstico final. Assim a associação entre informática e radiologia básica, traduzidas como radiologia digital, fez-se conseguir os fatores buscados. Uma ferramenta dos sistema digitais é a calibração prévia às medidas. Com essas observações avaliamos tais ferramentas de três sistemas de radiografias digitais, objetivando validar e comprovar sua eficácia nas metodologias dos trabalhos presentes e futuros. Para tanto utilizamos 20 dentes humanos secos provindos do Banco de Dentes Permanentes da FOUSP, os quais foram radiografados com o auxílio de três sistemas de radiografia digital, direto e semidireto (Digora, RVG Trophy e Visualix). O padrão ouro das medidas dos dentes foi a verificação das dimensões dos dentes por meio de um paquímetro digital e posteriormente comparados os seus padrões de medidas com os softwares dos respectivos sistema. Os resultados foram analisados estatisticamente pelo ANOVA (métodos de Tukey e Dunnett), chegando às seguintes conclusões: existe diferença significante entre os aparelhos p<0,001; a média das medidas obtidas houve diferença significante (p<0,001) com o aparelho Digora foi menor que as médias obtidas com os aparelhos das marcas Visualix e RVG; considerando-se o padrão A e o padrão B de calibragem, não existe diferença estatística significante entre os avaliadores; considerando-se a calibragem sem padrão, um dos avaliadores obteve média mais elevada que os demais avaliadores no caso das medidas realizadas com o aparelho Digora, porém este fato não se repetiu quando da utilização dos outros aparelhos; comparando-se as medidas de referência (paquímetro) observa-se que mais uma vez o aparelho Digora (padrão A, padrão B e sem padrão) apresentou diferença significativa; os aparelhos das marcas Visualix e RVG não mostraram diferenças significativas quando comparados com o valor de referência. / Technological development aims at reducing exposure of both the professional and the patient to ionizing radiation, improving patient treatment and aiding final diagnosis. The combination of computer technology and radiology, i.e. digital radiography, has made this possible. One of the tools of digital radiography systems is calibration prior to measurement. The purpose of this study was to assess the calibration tools of three digital radiography systems to verify their efficacy. Twenty human teeth obtained from the Human Teeth Bank of the School of Dentistry, University of São Paulo, were used. The dry teeth were radiographed using three different direct digital radiography systems Digora, RVG Trophy and Visualix. The measurements of the teeth obtained with a digital caliper were considered the gold standard. These measurements were later compared with those obtained using the digital systems. The results were submitted to ANOVA (methods of Tukey and Dunnett), and the following conclusions were drawn: there was a significant difference between the systems used (p < 0.001); the averages of the measurements obtained with the three systems were significantly different (p<0,001). Visualix and RVG were more accurate than Digora considering A and B calibration standards, no significant difference was observed between the examiners; when there was no calibration standard and the Digora system was used, one examiner obtained more high averages measurements than the others; when there was no calibration standard and Visualix or RVG systems were used, no differences were observed between the examiners; the measurements obtained with Digora system (standards A, B or no standard) were statistically different from the gold standard the measurements obtained with Visualix and RVG systems presented no significant difference when compared with the gold standard.
30

Influência dos meios de apresentação da imagem digital no diagnóstico e tratamento da cárie proximal realizado por alunos da graduação em Odontologia / Influence of the media presentation of digital imaging in the diagnosis and treatment of proximal caries performed by undergraduate students

Barbosa, Vera Lúcia Sales de Araújo 05 June 2011 (has links)
Made available in DSpace on 2015-09-25T12:18:22Z (GMT). No. of bitstreams: 1 Vera Lucia Sales de Araujo Barbosa.pdf: 906152 bytes, checksum: 9d151c05eda7ec83b62804ab3fd0e88c (MD5) Previous issue date: 2011-06-05 / The aim of this study was to assess the influence of the different digital radiographic display means on proximal caries detection and the consequent treatment decision chosen by undergraduates. 40 digital images of human extracted teeth were obtained. The proximal surfaces of those teeth were evaluated for the presence of proximal caries by 36 dentistry undergraduates, divided in three groups base on their degree of knowledge. For each surface, the chosen therapeutic treatment should also be indicated. The evaluations were done on a laptop and on printed digital images using a negatoscope. The accuracy of the display means for incipient caries detection was evaluated by the means of the areas under ROC curve (Az) and its effect by mixed linear regression. For the chosen therapeutic treatment sediment analyses was done to verify its adequacy to the diagnosis. There was no significant effect neither for the display modality (p=0.058), nor to the student groups (p=0.991). The mean area under the ROC curve for the printed images was 0.539 and 0.516 digital images. Treatment decision was consistent with the chosen diagnosis. The accuracy of proximal caries detection on digital images viewed in a laptop was comparable to printed images. The therapeutic decision was not affected by the digital radiographic image display modalities. The undergraduate progression on dentistry program does not enhance their precision to detect proximal caries. / O objetivo do presente estudo foi investigar a influência do meio de apresentação da imagem radiográfica digital no diagnóstico da cárie proximal e na decisão de tratamento dele decorrente, realizado por alunos de graduação. Foram obtidas 40 imagens digitais de dentes humanos extraídos. As superfícies proximais dos dentes foram avaliadas quanto à presença de cárie proximal por 36 estudantes de odontologia, distribuídos em três grupos de acordo com o nível de formação. Para cada superfície foi também indicada a terapêutica considerada mais adequada. As avaliações foram efetuadas em um laptop e em imagens impressas com o auxílio do negatoscópio. A acurácia dos meios de apresentação quanto à detecção de cárie incipiente foi avaliada pela média das áreas sob as curvas ROC e seu efeito por uma análise de regressão linear mista. Para a tomada de decisão terapêutica foi realizada uma análise de resíduos para verificar sua adequação ao diagnóstico. Não houve efeito significativo nem para a modalidade de visualização (p=0.058) e nem para os grupos de alunos (p=0.991). A média das áreas sob as curvas Roc para o filme foi de 0.539 e de 0.516 para laptop. A decisão de tratamento foi condizente com o diagnóstico efetuado. A acurácia do diagnóstico da cárie proximal realizado em tela de laptop é comparável ao realizado em negatoscópio. A tomada de decisão terapêutica não foi afetada pelo meio de apresentação da imagem radiográfica digital. A progressão do aluno no curso não melhora a precisão diagnóstica da cárie proximal.

Page generated in 0.0271 seconds