111 |
Influencia de gessos de inclusão e tempos pos-prensagem na adaptação de bases de protese total superior polimerizadas com energia de microondasAbreu, Ricardo Teixeira 03 August 2018 (has links)
Orientadores : Saide Sarckis Domitti, Simonides Consani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-03T14:40:33Z (GMT). No. of bitstreams: 1
Abreu_RicardoTeixeira_M.pdf: 17366541 bytes, checksum: 52e9fa145d98172f597b993bba61e992 (MD5)
Previous issue date: 2003 / Mestrado
|
112 |
Analise in vitro da resistencia ao cisalhamento de braquetes metalicos colados em varias condições de esmalteRomano, Fabio Lourenço 03 August 2018 (has links)
Orientadores: Maria Beatriz Borges de Araujo Magnani, Lourenço Correr Sobrinho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-03T19:01:09Z (GMT). No. of bitstreams: 1
Romano_FabioLourenco_M.pdf: 652972 bytes, checksum: 9ad8cc42b5869946d1b78d8003552d1b (MD5)
Previous issue date: 2003 / Mestrado
|
113 |
Estudo de fatores influentes na dureza superficial de um composito fotoativadoAguiar, Flávio Henrique Baggio, 1977- 06 September 2004 (has links)
Orientador : Jose Roberto Lovadino / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-03T23:46:52Z (GMT). No. of bitstreams: 1
Aguiar_FlavioHenriqueBaggio_D.pdf: 443566 bytes, checksum: 6e7b1cc9c9c084e46175fdb16dd4fd2e (MD5)
Previous issue date: 2004 / Resumo: A qualidade de polimerização dos compósitos dentais é um importante parâmetro a ser considerado para o sucesso clínico da restauração realizada. Muitos fatores podem interferir na quantidade de energia luminosa que um incremento de compósito recebe, entre eles, a distância entre a ponta do aparelho de fotoativação e a superfície do compósito, a intensidade do aparelho de fotoativação, a especificidade de luz emitida pelo aparelho de fotoativação, o tempo de fotoativação, cor, opacidade e espessura do compósito. Assim, o objetivo deste trabalho, composto por quatro experimentos, foi avaliar as influências: 1) da cor do compósito na dureza superficial de topo e fundo, em simulação clínica na qual a ponta do aparelho de fotoativação estava distante 2, 4 e 8mm da superfície de topo do compósito; 2) do modo e do tempo de polimerização na dureza superficial de topo e fundo, em simulação clínica na qual a ponta do aparelho de fotoativação estava distante 8mm da superfície de topo do compósito; 3) da espessura do compósito na dureza superficial de topo e fundo, em simulação clínica na qual a ponta do aparelho de fotoativação estava distante 2, 4, 6 e 8mm da superfície de topo do compósito; 4) da espessura do compósito e do modo de polimerização na dureza superficial de topo e fundo, em simulação clínica na qual a ponta do aparelho de fotoativação estava distante 8mm da superfície de topo do compósito. Com base nos resultados obtidos e sob as condições experimentais deste estudo, pôde-se concluir que: 1) a dureza da superfície de topo foi pouco afetada pelos fatores estudados, não sendo um parâmetro adequado para mostrar a eficácia de polimerização do compósito, entretanto a dureza da superfície de fundo foi consideravelmente afetada pelos fatores analisados; 2) a distância entre a ponta do aparelho de fotoativação e a superfície do compósito foi um fator relevante, pois quanto maior esta distância, menor foi a dureza da superfície de fundo do compósito; 3) o compósito teve a capacidade de reduzir a penetração da energia luminosa, e conseqüentemente reduzir significativamente a dureza da superfície de fundo, independentemente dos fatores estudados; 4) quando a distância entre a ponta do aparelho de fotoativação e a superfície do compósito for superior a 4mm, deve-se triplicar o tempo de polimerização; utilizar cores claras, desde que não haja comprometimento de estética e fontes de luz eficientes, comprovada por estudos científicos com credibilidade; 5) quando a distância entre a ponta do aparelho de fotoativação e a superfície do compósito for igual ou superior a 2mm, devese utilizar incrementos de até 1mm de espessura, e, se a distância for igual ou superior a 8mm, a espessura do incremento deve ser de 0,5mm / Abstract: Adequate resin composite polymerization is a crucial factor in obtaining optimal physical performance of these materials. Several variables can affect the amount of light energy received at the top and bottom surfaces of a resin composite increment, such as, distance of the light guide tip from the resin composite, power density, light energy mode, exposure duration, shade and opacity of the resin composite and increment thickness. Thus, the aim of this study composed of four manuscripts was to evaluate the influence: 1) of the resin composite thickness on top and bottom microhardness, in a clinical simulation when the light curing tip was 2, 4, 6 and 8mm distant from the resin composite top surface; 2) of the resin composite shade on top and bottom microhardness, in a clinical simulation when the light curing tip was 2, 4, and 8mm distant from the resin composite top surface; 3) of light curing modes and light curing time on top and bottom microhardness, in a clinical simulation when the light curing tip was 8mm distant from the resin composite top surface; 4) of light curing modes and resin composite sample thickness on top and bottom microhardness, in a clinical simulation when the light curing tip was 2, 4, and 8mm distant from the resin composite top surface. Based on the results, within the experimental limits of this study, it can be concluded that: 1) the top surface microhardness was a little affected by the experimental factors, and it was not an adequate parameter to show the polymerization effectiveness of the resin composite, mainly of the bottom surface. However, the bottom surface microhardness was substantially affected by the studied factors; 2) the distance between of the light guide tip and the resin composite top surface is a factor that must be carefully analyzed, because as higher was the distance, as lower was the microhardness of the resin composite bottom surface; 3) resin composite has the capacity of reducing the light energy penetration, and consequently, the polymerization effectiveness of the bottom surface of the sample, independent of the others factors studied; 4) when the distance between of the light guide tip and the resin composite top surface is superior to 4mm, it should increase the light curing time at least three times; use light resin composite shades, since they do not have any esthetic involvement; and use efficient light curing devices; 5) when the distance between of the light guide tip and the resin composite top surface is superior or equal to 2mm, it should use resin composite increments of 1mm thick / Doutorado / Dentística / Doutor em Clínica Odontológica
|
114 |
Otimização da produção do xarope de açucar invertido atraves do uso de resinas de troca-ionicaRodrigues, Marili Villa Nova 1965- 11 December 1998 (has links)
Orientador: Telma Teixeira Franco / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Alimentos / Made available in DSpace on 2018-07-24T10:44:11Z (GMT). No. of bitstreams: 1
Rodrigues_MariliVillaNova1965-_M.pdf: 4747447 bytes, checksum: 5ab8804c26c3ec52e68b2092f0029b53 (MD5)
Previous issue date: 1998 / Resumo: A sacarose proveniente da cana-de-açúcar é uma matéria-prima abundante em nosso país com uma produção anual de cerca de 12 milhões de toneladas. A utilização desse açúcar para a produção de açúcar líquido pode ser uma alternativa economicamente viável, uma vez que a utilização do açúcar na forma líquida facilita o manuseio e o transporte e tem uma ampla utilização na indústria alimentícia. O termo "açúcar líquido" se aplica igualmente para uma simples solução de sacarose em água como para misturas mais complexas, as quais podem conter vários açúcares (sacarose, glicose e frutose) além de outros constituintes, por exemplo, sais orgânicos ou inorgânicos. Porém, o principal interesse desse trabalho foi otimizar a produção do xarope de açúcar invertido (55% de inversão) através da utilização de resinas de troca-iônica. A grande vantagem da utilização do xarope invertido se deve ao fato de combinar a elevada solubilidade da frutose à difícil cristalização da glucose, conferindo um maior poder adoçante e diminuindo os riscos de cristalização. O processo de obtenção do xarope invertido (55%) se iniciou com a descoloração do xarope de sacarose através da eluição em duas colunas contendo resinas aniônicas e subsequente eluição através da coluna de resina catiônica, responsável pela hidrólise da sacarose no grau de inversão desejado. Para a otimização do processo foi utilizada a metodologia de análise de superfície de resposta, através de dois planejamentos fatoriais completos 23, um para a etapa de descoloração do xarope e outro para a inversão propriamente dita. As variáveis foram a concentração do xarope de sacarose, a taxa de aplicação e a temperatura, para os dois planejamentos. A condição otimizada partiu de um xarope de sacarose 60°B eluído a 4VL/h através das colunas aniônicas, a IRA-958 (acrílica) e a IRA-900 (estirênica) operando a 58°C, para então ser invertido na coluna contendo resina IR 120 a 2VL/h e 38°C. O produto final obtido foi de alta qualidade, ou seja, com baixos teores de hidroxi metil furfural (HMF), cor e cinzas, inodoro, sem objeções ao paladar e estável microbiologicamente / Abstract: Sucrose obtained from sugar cane is an abundant raw material with an annual production of approximately 12 million tons. Economically, liquid sugar derived from sucrose can be a viable option for widespread use in the food industry. This would make handling and transportation processes easier. The term "liquid sugar" is applied equally to a simple solution of sucrose in water or to more complex mixtures, wich may contain several sugars (sucrose, glucose, frutose) as well as organic or inorganic salts. Therefore our goal was to optimize the inverted syrup production (55% inversion) using ion exchange resins. A great advantage of inverted syrup is the high frutose solubility coupled to poor crystallization of glucose permitting increase in sweetness with less risks of crystallization. The production of inverted syrup began with sucrose decolorization process employing two anionic resins columns and subsequent elution through a cationic resin column, which promoted sucrose hydrolysis until inversion level desired. The response surface by two complete factorial methology was used to optimize the experiment, one used in the decolorization process and the other in the inversion process. The variables considered were sucrose concentration, application rate and temperature. The optimized conditions started with 60°B sucrose syrup eluted at 4BV/h through the IRA-958 (acrylic) and IRA-900 (styrenic) anionic resins columns at 58°C following sucrose inversion through IR 120 cationic resin column at 2BV/h and 38°C. The resulting product exhibited high quality, low levels of hydroxymethylfurfural (HMF), color and ashes, scentless, microbiology stability, as well as no taste unpleasantness / Mestrado / Mestre em Tecnologia de Alimentos
|
115 |
Analise da Sorção de agua em amostras de resina acrilica ativada termicamente e submetida a alterações de pressão, temperatura e tempoFraga, Marco Aurelio 17 December 1998 (has links)
Orientador: Celia Marisa Rizzatti Barbosa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-24T14:48:28Z (GMT). No. of bitstreams: 1
Fraga_MarcoAurelio_M.pdf: 2300241 bytes, checksum: b3d505b92d41270efebc5938157fa89c (MD5)
Previous issue date: 1998 / Resumo: O objetivo do presente trabalho foi estudar a sorção de água de amostras de resina acrílica termopolimerizável, submetidas a alterações de pressão e temperatura em função do tempo. Foram confeccionadas 45 amostras de acordo com a especificação n° 12, da 'American Dental Association POT. 13¿. As amostras foram subdivididas em 9 grupos com 5 repetições cada um. As 5 amostras do Grupo I foram consideradas controle, e após confeccionadas, foram submetidas ao seguinte tratamento (GI): imersão em água destilada a 37 ' + OU ¿ ' 2 °C, à pressão ambiente durante 30 dias. Os demais grupos receberam os seguintes tratamentos: imersão em água destilada a 70 ' + OU ¿ ' 2 °C, à pressão de 40 Lb. por 60 minutos (GIl ), à pressão de 60 Lb. por 60 minutos (GIII), à pressão de 40 Lb. por 90 minutos (GIV), à pressão de 60 Lb. por 90 minutos (GV); imersão em água destilada a 90 ' + OU ¿ ' 2 °C à pressão de 40 Lb. por 60 minutos (GVI), à pressão de 60 Lb. por 60 minutos (GVII) , à pressão de 40 Lb. por 90 minutos (GVIII), e à pressão de 60 Lb. por 90 minutos (GIX). Após estes tratamentos, as amostras foram submetidas ao teste de sorção de água descrito na especificação n° 12, da 'American Dental Association POT. 13¿. Os resultados, após terem sido submetidos à análise estatística, permitiram concluir que os índices de sorção de água apresentados pelas amostras de resina polimerizada a 73 °C por 9 horas, armazenadas em água à temperatura de 90 ' + OU ¿ ' 2 °C, apresentaram valores compatíveis aos das amostras do grupo controle, não havendo influência da pressão de 40 ou 60 Lb. sobre estes índices / Abstract: The aim of this study was to observe the water sorption by heat-eured polymethyl methaerylate resin samples, submitted to pressure and temperature alterations, according to timing. Forty-five samples were made in aeeordanee to Specification #12 of the 'American Dental Association POT. 13¿. The samples were divided in 09 groups with 05 samples each one . The five samples to Group 1 ( GI) were taken as control group and after being crafted they were submitted to the following treatment: immersion in distilled water at 37 ' + OU ¿ ' 2 °C, at ambient pressure, for 30 days. The other groups were given the following treatment: immersion in distilled water at 70 ' + OU ¿ ' 2 °C, under a 40 Lb. pressure for 60 minutes (GII), under a 60 Lb. pressure for 60 minutes (GIll), under a 40 Lb. pressure for 90 minutes (GIV), under a 60 Lb. pressure for 90 minutes (GV); immersion in distilled water at 90 ' + OU ¿ ' 2 °C under a 40 Lb. Pressure for 60 minutes (GVI), under a 60 Lb. pressure for 60 minutes (GVII), under a 40 Lb. pressure for 90 minutes (GVIIl), and under a 60 Lb. pressure for 90 minutes (GIX). After this procedures the samples were submitted to the water sorption test described by Specification # 12 of 'Ameriean Dental Association POT. 13¿ . The results, after statisties analysis permitted to, conclude that the water sorption presented by the resin polymethyl samples, cured by 73°C by 9 hours, stored in water under 90 ' + OU ¿ ' 2 °C, presented the same values of the control group, not occuring influence by pressure of 40 or 60 Lb. on this scores / Mestrado / Protese / Mestre em Clínica Odontológica
|
116 |
Modificação de resinas de poliester insaturado com poli(organossiloxanos)Rosa, Valeria Maria 25 July 2018 (has links)
Orientador: Maria Isabel Felisberti / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-07-25T23:42:24Z (GMT). No. of bitstreams: 1
Rosa_ValeriaMaria_D.pdf: 4863713 bytes, checksum: ff7635cf43290486216e32d1e534c4b1 (MD5)
Previous issue date: 1999 / Doutorado
|
117 |
Alteração de cor de resinas compostas imersas em diferentes meios liquidosFreitas, Francisco Jose Guimarães de, 1962- 14 July 2018 (has links)
Orientador : Oreste Benatti / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-14T01:25:38Z (GMT). No. of bitstreams: 1
Freitas_FranciscoJoseGuimaraesde_M.pdf: 3030969 bytes, checksum: 2843f82a83ed20a142556aeef2632757 (MD5)
Previous issue date: 1989 / Resumo: O presente trabalho teve por objetivo principal avaliar as alterações de cor de 3 resinas compostas, imersas em
diferentes meios líquidos, por um período de tempo não superior a 30 dias. Visou, também, buscar uma possível correlação
entre essas alterações e fatores, tais como: concentração, tamanho das partículas de carga e pH dos meios a que estavam expostos os materiais. Os registros. das alterações de cor, a intervalos de tempo diferentes, foram feitos através de fotomicrografias. Os resultados analisados permitiram concluir que: (1) corpos de prova representativos de resinas compostas'
convencionais, quando submetidos aos procedimentos de acabamento e polimento, tornam-se mais suscetíveis à descoloração d.oque os com pó si tos com micropartículas. , (2) os ácidos orgânicos, presentes nas soluções antissépticas, parecem ter atacado a superfície dos compósitos, principalmente nos primeiros 7 dias de estudo, favorecendo, ainda mais, sua descoloração;
(3) a concentração das partículas de carga parece não contribuir tanto para a descoloração do material, quanto o faz o seu tamanho. Tal fato foi, aqui, comprovado pela menor descoloração apresentada pelo Herculite em relação ao Adaptic / Abstract: The present study was carried out to evaluate the color change of three different composite resins, after being
immersed in some antiseptical solutions for a period of time not over 30 days. .It was also the aim of the present study to
search for a correlation between these alterations and factors, such as: concentration, size of the fillers and pH of the solutions to which the specimens were.exposed. The registers oÍ the color alterations were taken through photomicrographs at ifferent intervals of time. The results, once analysed, haveshown that: (1) specimens representing conventional composte resins, become more sensitive to color change after usual finishing and polishing proceduresi (2) organic acids, present in the antiseptical solutions,
seem,to have attacked the composite surface, mainly on the first seven daysof study, which contributed alI the more to its discolorationi (3) the filler concentration, when compared with its size, doesn't seem to produce an outstanding discoloration of
the composite. Such a fact was, here, confirmmed by the smallest discoloration presented by Herculite in relation to Adaptic / Mestrado / Materiais Dentarios / Mestre em Odontologia
|
118 |
Insolubilização da amiloglicosidase em resina : estudo de suas propriedades e cineticaPark, Yong Kun, 1930- 11 February 1972 (has links)
Orientador: Paulo Bobbio / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Tecnologia de Alimentos / Made available in DSpace on 2018-07-15T04:18:42Z (GMT). No. of bitstreams: 1
Park_YongKun_D.pdf: 2599752 bytes, checksum: 20e36d31652d348e3984265277d55f85 (MD5)
Previous issue date: 1972 / Resumo: Não informado. / Abstract: Not informed. / Doutorado / Doutor em Ciências
|
119 |
Avaliação in-vitro da microinfiltração em cavidades classe II restauradas com composito de alta viscosidade submetidas a carregamento oclusal ciclicoCampos, Paulo Eduardo Gomes de Almeida 03 February 2005 (has links)
Orientador: Luiz Roberto Marcondes Martins / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-04T05:06:37Z (GMT). No. of bitstreams: 1
Campos_PauloEduardoGomesdeAlmeida_D.pdf: 8753505 bytes, checksum: 034f3405e72c655051af31b0d4894dd8 (MD5)
Previous issue date: 2005 / Resumo: Objetivou-se neste trabalho avaliar a microinfiltração cervical em restaurações diretas classes II com variação de 4 materiais e a influência do carregamento oclusal cíclico. 80 terceiros molares humanos recém extraídos, foram armazenados em Timol a 0,5% até o início do experimento. Todos os dentes receberam o mesmo tipo de preparo, ¿slot¿ vertical proximal, com as mesmas dimensões, exceto no limite das paredes cervicais, que em uma proximal localizou-se em esmalte (1mm acima da junção esmalte cemento - JEC) e em dentina (1mm abaixo da JEC), sem biselamento das margens. Utilizou-se o sistema adesivo Single Bond (3M) e compósito restaurador Filtek P60 em todas os espécimes com variação de 3 materias restauradores somente à parede cervical (Filtek Flow, Dyract AP e Vitremer). Os 80 dentes foram divididos de acordo com o tipo de tratamento: 4 grupos controles (sem receber carregamento oclusal) e 4 grupos testes (recebendo carregamento oclusal). Concluídas as restaurações, os dentes foram armazenados em água deionizada por 7 dias. Em seguida 40 espécimes receberam 4000 mil ciclos de carregamento oclusal de 150 N com duração de 1segundo. Após este procedimento os dentes foram imersos em solução de nitrato de prata a 50% por um período de 24 horas. Em seguida foi avaliado o grau de microinfiltração pelo corante com auxílio de lupa estereoscópica com aumento de 40 vezes por 2 examinadores treinados, de acordo com o seguinte escore pré-definido: 0- ausência de penetração, 1- penetração até a metade da extensão da parede cervical (considerada leve), 2- penetração em toda a extensão da parede cervical sem alcançar a parede axial (considerada moderado) e 3- penetração em toda a extensão da parede cervical alcançando a parede axial (considerada severa). Os dados foram submetidos à 3 testes não paramétrico. No teste Wilcoxon encontrou-se diferenças estatisticamente significativas (p<0,05). No teste Mann-Whitney, encontrou-se diferenças estatisticamente significativas (p<0,05) do grau de infiltração no esmalte; na dentina, só não foi encontrada diferença estatisticamente significativa em relação ao grupo no material Flow. No teste de Kruskal-Wallis não detectou-se nenhuma diferença estatisticamente significativa do grau de infiltração entre os 4 materiais estudados. Com base nos dados coletados, concluiu-se que as restaurações que tiveram suas margens localizadas em dentina tiveram maior grau de microinfiltração que as localizadas em esmalte. Quando os espécimes foram submetidos ao carregamento oclusal, os índices de microinfiltração tanto em esmalte quanto em dentina aumentaram. Quando comparou-se o desempenho dos 4 materiais restauradores diretos às paredes em esmalte e em dentina não encontrou-se diferenças estatisticamente significantes entre os matérias estudados / Abstract: The objective of this work was to evaluate the cervical microleakage in class II direct restorations with four direct restoration materials, and the influence of occlusal cyclic loading over these restorations. Eighty recently extracted third molar human teeth, were stored in 0,5% Timol until the experiment. All the teeth received the same kind of cavity preparation, proximal slot, with the same dimensions, except in the limit of the cervical walls which in a proximal was located in enamel (1mm above the enamel-dentin junction ) and in the other was located in dentine (1mm below the enamel-dentin junction). None of the margins of the prepare were beveled. It was used the Single Bond (3M-ESPE) dentinal adhesive system and the Filtek P60 composite resin in all samples and the material used to restore the cervical wall were changed into the groups (Filtek Flow, Dyract AP, Vitremer). The samples were then divided according to the kind of treatment: four control groups (without cyclic occlusal loading) and four experimental groups (with cyclic occlusal loading). After all the restorations were concluded, samples were stored in distilled water for a week. After that, forty samples received 4000 one second cycles of 150 N occlusal loading . After this procedure the samples were immersed in silver nitrate solution for twenty-four hours. Then, microleakage degree was evaluated by means of a 40X stereoscopic magnifying glass by two pre-calibrated examiners, according to the following score: 0= No penetration, 1= penetration until the half of the extension of the cervical wall, considered light, 2= penetration in all the extension of the cervical wall without reaching the axial wall, considered medium and 3= penetration in every extension of the cervical wall, reaching the axial wall, considered severe. Results were statistically analyzed by three non-parametric tests. The Wilcoxon test showed that the groups were statistically differents (p< 0,05). The Mann-Whitney test found, in enamel, for all kinds of materials, statistically significant differences (p< 0,05) of the leakage degree, regarding the group (control and loading). In dentine, it was not found a statistically significant difference regarding the group only in the flow material. The Kruskal-Wallis test did not detect any statistically significant difference of the leakage degree between the four studied materials. Based in this collected data, it was concluded that the restorations that had its margins located in dentine had larger microleakage degree than the located in enamel. When the samples were submitted to the occlusal loading, they were negatively influenced, increasing microleakage values in enamel and in dentine. Comparing itself the performance of the four tested materials, it was not detected any statistically significant difference among them / Doutorado / Dentística / Doutor em Clínica Odontológica
|
120 |
Estudio comparativo, in vitro, del grado de fluorescencia de resinas compuestas presentes en nuestro mercadoCastillo Lay, David January 2009 (has links)
Trabajo de Investigación Requisito para optar al Título de Cirujano Dentista / Autor no autoriza el acceso a texto completo de su documento / Los dientes al igual que muchas sustancias en la naturaleza
poseen propiedades que les son propias, forma, tamaño, textura, brillo,
color, etc. al perderse tejido dentario, el profesional Odontólogo de ejercicio
clínico, se ve en la obligación de seleccionar, dentro de una amplia gama, el
material más idóneo para efectuar su labor, dentro de los materiales
restauradores uno de los de mayor demanda, y uso, son las resinas
compuestas por su versatilidad, gran gama de colores, relativa facilidad de
empleo y bajo costo
(
relativo también.
)
, las resinas presentan muchas
propiedades pero una a la que se hace escasa o nula referencia en los
manuales, folletos e instructivos que nos entregan los fabricantes de
resinas, es la fluorescencia que estas presentan, y si es similar o no a las
piezas dentarias, esto resulta de mucha importancia cuando se llevan a cabo
reconstrucciones del sector anterior, pues algunos pacientes están
expuestos a luces U.V.
(
muy frecuentes en discotecas, pub´s y estudios de
cine o televisión.
)
y si el diente reconstruido con un material
(
resina.
)
que
presente un grado de fluorescencia muy distinto a la pieza natural se vera
muy oscuro o muy brillante, en comparación a las piezas
naturales no restauradas, dando un aspecto muy extraño a su dentadura.
Por lo anterior se hace necesario contar con una ayuda que permita
51
seleccionar dentro de los materiales de los cuales se dispone, el que más se
asemeja al comportamiento de un diente natural, en el presente estudio se
observo el grado de fluorescencia de 21 resinas, todas presentes en nuestro
mercado nacional, comparándose entre si y con los tejidos dentarios,
esmalte y dentina; obteniéndose valores para cada una, evidenciando que
existen algunas semejantes, en grado de fluorescencia, a las estructuras
dentarias, así como otras muy diferentes, tanto muy oscuras como
extremadamente fluorescentes.
|
Page generated in 0.0501 seconds