• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Contrôle des propriétés magnéto-optiques de systèmes magnétoplasmoniques grâce à la nanostructuration / Tailoring magneto-optical properties of magnetoplasmonic systems through nanostructuration

Ding, Xiaokun 24 January 2017 (has links)
Ce travail de thèse porte sur le contrôle des propriétés de trois systèmes magnéto-plasmoniques grâce à différents types de nanostructuration. Ces structures sont basées respectivement sur la Propagation de Plasmons de Surface (SPP), les Plasmons de Surface Localisés (LSP) et la spectroscopie d’interférences en réflexion (RIfS). La manipulation des propriétés magnéto-optiques (MO) pour une utilisation dans les biocapteurs est discutée. Le premier système est une structure SPP en couche mince de couches de métaux nobles et d’un matériau magnétique de type multicouche présentant une anisotropie uni-axiale contrôlée. L’anisotropie de la couche magnétique se reflète sur les propriétés plasmoniques. Une amélioration de l’activité magnéto-optique peut être mise à profit pour améliorer la sensibilité de capteurs basés sur cette structure. Le second dispositif est une structure LSP avec nanoparticules d’or et d’une couche magnétique continue. Il est démontré qu’une couche diélectrique entre la couche magnétique et les nanoparticules d’or est indispensable pour préserver la résonance plasmonique. L’épaisseur de la couche magnétique a un effet sur cette dernière qui peut en principe être mise à profit pour influer sur l’activité magnéto-optique. La troisième approche est une structure RIfS composée d’un système multicouche magnéto-plasmonique Ag/ITO/CoFeB/ITO/Ag déposé sur un substrat nanoporeux d’oxyde d’aluminium anodique (AAO). Le signal RIfS dépend de la taille et de la longueur des nanopores. Le diamètre des nanopores affecte également la réponse magnéto-optique en réflexion en générant une inversion du signe des cycles d’aimantation mesurés par effet Kerr. / This PhD dissertation deals with the tuning of the magneto-optical (MO) response of three different magnetoplasmonic systems by using different nanostructuration schemes. They are structures based on SPPs, LSPs and RIfS, respectively. The manipulation of MO activity to be used in biosensors and to improve the sensitivity is also discussed. The first system is thin-film SPP structure consisting of magnetic and plasmonic layers, where the magnetic part is nanostructured multilayers with controlled uni-axial anisotropy. The uni-axial anisotropic properties of the multilayered magnetic materials were clearly reflected on the plasmonic properties of the system. An enhancement in the MO activity can be used to improve the sensitivity of the sensors based on this structure. The second system is a LSP-based magnetoplasmonic structure consisting of Au nanoparticle arrays and continuous magnetic layers. It is demonstrated that a dielectric layer in between Au nanoparticles and ferromagnetic layers is indispensable in order to preserve the plasmonic resonance. The thickness of magnetic layers has an effect on the plasmonic property, which can be further used to tune the MO activity. The third system is a hybrid RIfS structure with a magnetoplasmonic multilayer Ag/ITO/CoFeB/ITO/Ag deposited on a nanoporous AAO substrate. The RIfS signal depends on both the size and the length of the nanopores. The diameter of the nanopores also affects the MO response by generating a reversal in the sign of the Kerr loops. This can be viewed as the tuning factor of MO activity of the structure.
2

Development of a Biomembrane Sensor Based on Reflectometry

Stephan, Milena 10 June 2013 (has links)
Membranproteine spielen eine wichtige Rolle in vielen biochemischen Prozessen der Zelle, wie zum Beispiel der Signaltransduktion, der Zelladhesion oder auch der Erkennung von Krankheitserregern. Viele dieser Proteine sind von Bedeutung für die Entwicklung neuer innovativer Medikamente. Somit hat auch die Entwicklung von Sensoren, die die Untersuchung von Membranproteinen in ihrer natürlichen Umgebung erlauben an Bedeutung gewonnen [1]. Thema dieser Doktorarbeit war die Entwicklung von Analysekonzepten die es ermöglichen unterschiedliche Aspekte von Membraninteraktionen zu untersuchen und zu quantifizieren. Als Analysemethode wurde dafür reflektometrische Interferenz Spektroskopie (RIfS) eine markierungsfreie, optische Methode verwendet. RIfS erlaubt es die Höhe dünner transparenter Filme zu bestimmen, indem das Weißlicht-Reflexionspektrum eines solchen Films aufgezeichnet wird. Durch die Überlagerung der in dem Film mehrfach reflektierten Teilstrahlen entsteht ein Interferenzmuster im Reflexionsspektrum, welches Aufschluß gibt über die Schichtdicke und den Brechungsindex des transparenten Films. Es wurde bereits gezeigt, dass RIfS eine geeignete Methode zur Untersuchung von Protein-ProteinWechselwirkungen ist [2]. Aus diesem Grund wurde RIfS als Detektionsverfahren für die Entwicklung eines Membransensors gewählt. Im Laufe dieser Arbeit entstanden zwei Aufbauten für reflektometrische Messungen. Ein Standard RIfS Aufbau und ein Instrument das die Methode mit Fluoreszenz-Mikroskopie kombiniert. Um dieWechselwirkung von Proteinen selbst und Proteinen mit Membranbestandteilen wie Lipiden zu untersuchen, wurde ein Konzept basierend auf festkörperunterstützten Membranen entwickelt. Dieses Experiment erlaubt es die Wechselwirkungen auf artifiziellen Membranen, sowie auf rekonstituierten Zellmembranen zu untersuchen. Zudem wurde ein Analysekonzept mit Nano-BLMs entwickelt, dass es erlaubt den simultanen Transport von Molekülen in ein membranverschlossenes Kompartiment hinein als auch heraus zu beobachten. Neben diesen membranbasierten Experimenten wurde auch ein Konzept entwickelt, welches es erlaubt die molekulare Erkennungsreaktion von sehr kleiner Analyten direkt zu messen. Dieses Messkonzept erlaubt es die Bindung von Molekülen mit sehr kleinem Molekulargewicht an einen auf dem Sensor immobilisierten Partner direkt zu quantifizieren.

Page generated in 0.0279 seconds