• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 62
  • Tagged with
  • 63
  • 63
  • 43
  • 40
  • 30
  • 30
  • 28
  • 28
  • 17
  • 16
  • 16
  • 14
  • 14
  • 12
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Nano e microfibras luminescentes à base de poli[2-metóxi,5-etil(2-hexilóxi)parafenilenovinileno] - MEH-PPV e poli (cloreto de vinila) – PVC.

Braga, Nathália Oliveira January 2015 (has links)
Programa de Pós-Graduação em Ciências – Física de Materiais. Departamento de Física, Instituto de Ciências Exatas e Biológicas, Universidade Federal de Ouro Preto. / Submitted by Oliveira Flávia (flavia@sisbin.ufop.br) on 2015-05-27T17:50:58Z No. of bitstreams: 2 license_rdf: 22190 bytes, checksum: 19e8a2b57ef43c09f4d7071d2153c97d (MD5) DISSERTAÇÃO_NanoMicrofibrasLuminescentes.pdf: 7161943 bytes, checksum: 06a0b0605c7db83350d5104fe03f7e4f (MD5) / Approved for entry into archive by Gracilene Carvalho (gracilene@sisbin.ufop.br) on 2015-05-27T18:00:02Z (GMT) No. of bitstreams: 2 license_rdf: 22190 bytes, checksum: 19e8a2b57ef43c09f4d7071d2153c97d (MD5) DISSERTAÇÃO_NanoMicrofibrasLuminescentes.pdf: 7161943 bytes, checksum: 06a0b0605c7db83350d5104fe03f7e4f (MD5) / Made available in DSpace on 2015-05-27T18:00:02Z (GMT). No. of bitstreams: 2 license_rdf: 22190 bytes, checksum: 19e8a2b57ef43c09f4d7071d2153c97d (MD5) DISSERTAÇÃO_NanoMicrofibrasLuminescentes.pdf: 7161943 bytes, checksum: 06a0b0605c7db83350d5104fe03f7e4f (MD5) Previous issue date: 2015 / Este trabalho tem por objetivo principal fabricar nano e microfibras à base de polímeros luminescentes e avaliar seu potencial para utilização em novos sensores de radiação, sobretudo para fototerapia neonatal. Os materiais foram obtidos por meio da técnica de eletrofiação, que é reconhecida pela eficiência na fabricação de fibras poliméricas de baixa dimensionalidade e, portanto, permite a fabricação de dispositivos fotônicos com resoluções micro e nanométricas. Neste sentido, inicialmente fibras de poli(2-metóxi,5-etil(2-hexilóxi)parafenilenovinileno) - MEH-PPV e poli (cloreto de vinila) – PVC foram obtidas pela técnica de eletrofiação em diferentes proporções em massa de PVC:MEH-PPV. Em seguida, as fibras foram expostas à luz azul (λ = 460nm), de acordo com as condições ideais usadas no tratamento de hiperbilirrubinemia neonatal. Em seguida, as fibras foram caracterizadas morfológica, química e oticamente. Como um dos principais resultados experimentais obtidos destaca-se a fabricação de fibras com diâmetros entre 80 nm a 2 μm, cuja proporção de PVC:MEH-PPV influencia diretamente não apenas essa grandeza, como também o número de contas das fibras e a porosidade das fibras. Além disso, observa-se que não há influência aparente do radical cloro na cinética de degradação do MEH-PPV. Resultados de FTIR confirmam tal suposição. Finalmente as fibras responderam positivamente à exposição à luz azul atuando como dosímetro indicador dose-cor. Especificamente para aplicação médica em fototerapia neonatal, as fibras poderão ser usadas na composição de tecidos, tipo gases, que seriam empregados junto à pele do recém-nascido ictéricos como um sistema de dosímetro indicador dose-cor de fototerapia. Assim ter-sei-ia um dispositivo plástico, flexível e possivelmente “vestível” para envolver parte do neonato ictérico sob tratamento de fototerapia como uma nova aplicação em neonatologia.
12

Estudo das propriedades dosimétricas de polímeros conjugados

Vismara, Marcus Vinícius Gonçalves [UNESP] 31 March 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:30:18Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-03-31Bitstream added on 2014-06-13T21:00:47Z : No. of bitstreams: 1 vismara_mvg_me_bauru.pdf: 1607998 bytes, checksum: 8efc51b01e3badc0e6233d3ef3f7d4ab (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Este trabalho teve como objetivo a investigação da interação de radiação gama com três polímeros: o polímero Poli(2-metóxi, 5-(2'-etil-hexilóx)-1,4- fenileno vinileno) (MEH-PPV)n e os polímeros solúveis em água Poly {[2,5-bis(2-(N,N-diethylamino)ethoxy) -1,4 -phenylene]-alt-1,4-phenylene} e o Poly [(2,5-bis (2 - (N,N - diethylammonium bromide) ethoxy) - 1,4 -phenylene) - alt - 1,4-phenylene]. O polímero MEH-PPV foi dissolvido nos solventes orgânicos clorofórmio e bromofórmio, já os outros dois polímeros, em água destilada e solução de HCI 1M. As amostras foram preparadas em várias concentrações e irradiadas com doses que variaram desde 0,01 Gy, sendo que cada amostra foi irradiada com apenas uma dose. Os resultados foram avaliados com técnicas espectroscópicas, sendo elas, espectroscopia de absorção óptica UV-visível e espectroscopia de fluorescência. Foi avaliada a alteração na posição do pico principal de absorção óptica com a dose absorvida pelas amostras. Como resultado principal, observou-se que os polímeros solúveis em água não apresentam alteração espectral após serem irradiados. Não sendo interessante para aplicação dosimétrica. Já para as amostras do polímero MEH-PPV diluídas em bromofórmio apresentaram alta sensibilidade para doses inferiores a 1 Gy, e apresentaram certa linearidade com a dose recebida (fator importante para aplicação dosimétrica). Para as amostras em clorofórmio, não foi observado deslocamento significativo do escpectro de absorção para doses inferiores a 1 Gy. No entanto para doses de 1 Gy à 90 Gy, o comportamento observado pode ser descrito por duas regiões lineares: uma com maior inclinação da reta para doses até cerca 30 Gy, e outro com inclinação da reta menor para doses entre 30 Gy e 90 Gy. O comportamento linear, assim como a inclinação da reta, do deslocamento da posição... / The subject of this work is the investigation of gamma radition interaction with tree polymers: the polymer Poli(2-metóxi, 5-(2'-etil-hexilóx)-1,4- fenileno vinileno) (MEH-PPV)n e os polímeros solúveis em água Poly {[2,5-bis(2-(N,N-diethylamino)ethoxy) -1,4 -phenylene]-alt-1,4-phenylene} e o Poly [(2,5-bis (2 - (N,N - diethylammonium bromide) ethoxy) - 1,4 -phenylene) - alt - 1,4-phenylene]. The MEH-PPV polymer was dissolved in organic solvents, choloroform and bromoform, the other two polymers in distilled water and 1 M aqueous HCI solution. The samples were prepared at various concentrations and irradiated with doses ranging from 0.01 Gy to 90 Gy. The results were evaluated by spectroscopic techniques, which were, UV-visible absorption spectroscopy and fluorescence spectroscopy. They were evaluated the changes in the position of main optical absorption peak with the dose absorbed by the samples. As main result, it was observed that water-soluble polymers did not show spectral change after being irradiated. For dosimetric application this results are not interesting. For the MEH-PPV polymer samples diluted in bromoform presented highly sensitive to doses below 1 Gy, and showed some linearity with the dose received. For samples in chloroform, doses below 1 Gy did not showed significant shift in the absorption spectra. However, the samples irradiated with doses from 1 Gy to 90 Gy, the behavior can be described by two linear regions: one with a higher slope for doses up to about 30 Gy, and another with a lower slope for doses between 30 Gy and 90 Gy. A greater slope to doses up to about 30 Gy, and another with lower slope to doses between 30 and 90 Gy. The linear behavior and the slope of the main peak position is a important factor for dosimetric application. At the same time, a study of stability of the samples was performed. It was observed that the MEH-PPV samples in bromoform... (Complete abstract click electronic access below)
13

Aplicação da dosimetria de neutrons através de filmes finos de urânio natural e tório na datação pelo método dos traços de fissão

Iunes, Pedro Jose 20 October 1999 (has links)
Orientadores: Julio Cesar Hadler Neto, Giulio Bigazzi / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Fisica Gleb Wataghin / Made available in DSpace on 2018-07-26T17:27:23Z (GMT). No. of bitstreams: 1 Iunes_PedroJose_D.pdf: 1112661 bytes, checksum: e96e387655b068b4f8804e52605da41a (MD5) Previous issue date: 1999 / Resumo: Nesta tese foi proposta uma dosimetria de neutrons que se mostrou bastante apropriada para a datação de minerais com o Método dos Traços de Fissão (MTF). Esta dosimetria, baseada em filmes finos de urânio e de tório naturais, permite que o MTF possa ser utilizado como uma calibração absoluta. Além disto, ela torna possível a obtenção da razão Th/U do mineral a ser datado. A dosimetria de neutrons proposta foi aplicada na datação de uma amostra padrão e rendeu idades compatíveis com outros métodos de datação / Abstract: A neutron dosimetry , which was found to be very suitable for mineral dating through the Fission Track Method (FTM), was proposed in this doctoral thesis. This dosimetry , that is based on natural uraniun and thorium thin films, allows the use of the FTM as an absolute calibration. Besides, it makes possible to obtain the Th/U ratio of the mineral to be dated. The proposed neutron dosimetry was applied to date a standard sample, yielding ages that are compatible with other dating methods / Doutorado / Física / Doutor em Ciências
14

Contribuição ao estudo da variação de enzimas do globo ocular de cães : emprego de baixas doses de radiação e dosimetria termoluminescente

Boscolo, Frab Norberto, 1942- 14 July 2018 (has links)
Tese (livre docencia) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-14T12:14:45Z (GMT). No. of bitstreams: 1 Boscolo_FrabNorberto_LD.pdf: 1078809 bytes, checksum: d0e4d3a8eb1914b65b6a1d307529b23c (MD5) Previous issue date: 1984 / Resumo: Não informado / Abstract: Not informed / Tese (livre docencia) - Univer / Livre Docente em Radiologia Odontologica
15

Avaliação do quartzo como dosímetro pessoal baseado na luminescência opticamente estimulada / Evaluation of the quartz as personal dosimeter based on optically stimulated luminescence

Mineli, Thays Desirèe, 1985- 27 August 2018 (has links)
Orientadores: Eduardo Tavares Costa, André Oliveira Sawakuchi / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-27T00:20:49Z (GMT). No. of bitstreams: 1 Mineli_ThaysDesiree_M.pdf: 1544477 bytes, checksum: 80869854299a120a6e91842425c1e644 (MD5) Previous issue date: 2015 / Resumo: O uso de radiação ionizante é cada vez mais intenso, seja na indústria seja na área médica. Os efeitos nocivos da radiação ionizante exigem medidas de segurança na sua utilização e um dos meios mais comuns para proteção da saúde do operador de equipamentos que usam esta radiação é o controle da dose que este pode receber em determinado período de tempo. Para tal controle, são normalmente utilizados dosímetros pessoais. Estudos sobre datação de sedimentos costeiros e fluviais do Brasil têm encontrado tipos específicos de quartzo com excelentes características dosimétricas. Com o objetivo de analisar as propriedades dosimétricas de amostras de quartzo de elevada sensibilidade de luminescência e avaliar a sua possível utilização na dosimetria pessoal, foram feitos testes comparativos com amostra do principal e mais utilizado dosímetro pessoal do tipo OSL (Optically Stimulated Luminescence), o Al2O3:C. Este trabalho apresenta as características de luminescência de amostras de quartzo. Essas características foram determinadas por testes de recuperação de dose conhecida (dose recovery) por meio de protocolo de alíquota única (Single-Aliquot Regenerative ¿ SAR) em amostras irradiadas por fonte de radiação beta. Foram realizados testes de sensibilidade e de estabilidade do sinal OSL e testes com radiação gama. Os resultados mostraram que as amostras de quartzo estudadas foram capazes de recuperar com exatidão doses de 50 mGy a 50Gy. Estimou-se que as amostras de quartzo saturam em doses (114-175 Gy) superiores à dose de saturação da amostra de Al2O3:C (35 Gy). A dose mínima capaz de ser medida pelas amostras de quartzo variou de 0,2 mGy (para radiação gama) a aproximadamente 20 mGy (para radiação beta). As amostras de quartzo não apresentaram fading do sinal OSL. O sinal OSL ultravioleta da amostra de Al2O3:C cresceu com o tempo. A amostra de Al2O3:C apresentou maior sensibilidade em comparação às amostras de quartzo no teste com radiação beta. A sensibilidade da amostra de quartzo TE65B no teste com radiação gama foi superior à sensibilidade da amostra Al2O3:C. Estes resultados indicam que as amostras de quartzo estudadas têm potencial como material para dosímetros e incentivam estudos mais aprofundados para avaliar o uso destes tipos de quartzo como elementos sensores em dosímetros pessoais / Abstract: The use of ionizing radiation is becoming more intense, whether in industry or in the medical field. The harmful effects of ionizing radiation require safety measures in its use. One of the most common ways to protect the health of the operator of ionizing radiation equipment is the dose control that he/she can receive in a given time period. Personal dosimeters are used for this purpose. Studies on dating of coastal and fluvial sediments in Brazil have found quartz types with very high luminescence signal and excellent dosimetric characteristics. In order to analyze the dosimetric properties of very bright Brazilian quartz samples and evaluate their use in personal dosimetry, comparative tests with the most used personal OSL (Optically Stimulated Luminescence) dosimeter, Al2O3:C, were made. This work presents the luminescence characteristics of quartz samples. These characteristics were determined by dose recovery tests using a Single-Aliquot Regenerative dose protocol (SAR) in samples irradiated by beta radiation. Sensitivity and stability tests and gamma radiation tests were made. The results have shown that the studied quartz samples were able to recover at least a dose range from 50 mGy to 50 Gy. It was estimated that the quartz samples saturate in doses (114-175 Gy) above the saturation dose of Al2O3:C sample (35 Gy). The minimum dose capable of being measured by the quartz samples ranged from 0.2 mGy (for gamma rays) to about 20 mGy (for beta radiation). The quartz samples showed no fading of the OSL signal. The ultraviolet OSL signal of Al2O3:C sample increased with time. The Al2O3:C sample showed higher sensitivity compared to quartz samples in beta radiation test. However, the sensitivity of TE65B quartz sample for the gamma radiation test was higher than the sensitivity of the Al2O3:C sample. These results indicate that the studied quartz samples have potential as dosimeter material and encourage further studies to evaluate the use of this type of quartz as sensor element in personal dosimeters / Mestrado / Engenharia Biomedica / Mestra em Engenharia Elétrica
16

Correção de heterogeneidades para feixes de fótons de 6 MeV: comparações entre algoritmos de cálculo e medidas com TLD

Baptista, Cláudia Gonçalves 25 September 2009 (has links)
O presente trabalho mostra as diferenças de dose encontradas em meios de diferentes densidades eletrônicas, simulando tecido adiposo, muscular, ósseo e cavidade aérea, comparando medidas experimentais com feixe de fótons de 6 MeV e valores resultantes de algoritmos de cálculo existentes em um sistema de planejamento radioterápico. Para isso foram utilizados dosímetros termoluminescentes posicionados acima, dentro e abaixo de cada objeto simulador e medidos os perfis de dose ao longo do eixo longitudinal e do eixo transversal. As simulações computacionais foram realizadas com dois algoritmos de cálculo presentes na versão 8.5 do sistema de planejamento Eclipse: o Pencil Beam Convolution e o Analytical Anisotropic Algorithm. Comparando doses em um mesmo ponto, com e sem heterogeneidades, foram encontradas diferenças percentuais de até 12%, quando os algoritmos de correção de heterogeneidades não foram aplicados. Analisando essas comparações, pode-se observar também qual dos algoritmos de cálculo mais se aproxima dos valores experimentais, propondo ser o algoritmo de maior confiabilidade. / This work presents the dose variations obtained when phantoms of different electronic densities were used, simulating fat tissue, muscle, bones and air cavities, comparing experimental data with a 6 MeV photon beams and the values calculated by the treatment planning system algorithms. Thermoluminescent dosimeters were positioned above, inside and below each phantom measuring the dose along the depth and along a profile. The computational simulation was done by two algorithms that are part of Eclipse version 8.5: Pencil Beam Convolution and Analytical Anisotropic Algorithm. Comparing doses at the same point, with and without heterogeneities, percentages of 12% were found when heterogeneity correction was not used. These results also show which of the algorithms approaches better to the experimental values, becoming more reliable.
17

Dose gonadal e de exposição em crianças internadas em unidade de terapia intensiva pediatrica submetidas a exames radiograficos de torax

Menezes, Honorio Sampaio January 1990 (has links)
Orientador: Dirceu Rodrigues / Dissertação (mestrado) - Universidade Federal do Paraná, Setor de Ciências da Saúde, Programa de Pós-Graduação em Pediatria / Resumo: Foram estudadas 30 crianças, internadas na Unidade de Terapia Intensiva Pediátrica e submetidas a Raios X de tórax, com o objetivo de medir a dose de radiação de exposição e da dose de radiação gonadal recebida por estes pacientes. Foi medida a dose de exposição a radiação ionizante e a dose que atingiu as gônadas proveniente de 79 exames radiográficos. Foram analisados os parâmetros de exposição, absorção, dose gonadal com colimação e dose gonadal com colimação e protetor gonadal de chumbo, quilovoltagem,. miliamperagem, espessura torácica, distância foco filme, idade, tempo de internação e número de radiografias. As condições dos exames foram simuladas com simulador fantom de água. Verificou-se que: a radiação decorrente de exposição a exames radiográficos de tórax, na Unidade de Terapia Intensiva Pediátrica do Hospital de Clinicas da Universidade Federal do Paraná, quando comparada aos atuais limites para o público em geral, estabelecidos pela Comissão Internacional de Proteção Radiológica, não ultrapassa os mesmos; a radiação provenientes destes exames que atingiu as gõnadas dos pacientes estudados também está de acordo, a titulo de comparação, com os limites recomendados, ao público em geral, pela Comissão Internacional de Proteção Radiológica. 0 protetor gonadal com chumbo demonstrou ser um eficiente meio de redução da dose de radiação que atinge as gônadas. A radiação espalhada que atinge as gônadas provenientes dos exames acima citados é cerca de 0,2 por cento da dose de radiação de exposição, em condições similares as do estudo aqui apresentado. / Sem abstract
18

Estudo das propriedades dosimétricas de polímeros conjugados /

Vismara, Marcus Vinícius Gonçalves. January 2011 (has links)
Resumo: Este trabalho teve como objetivo a investigação da interação de radiação gama com três polímeros: o polímero Poli(2-metóxi, 5-(2'-etil-hexilóx)-1,4- fenileno vinileno) (MEH-PPV)n e os polímeros solúveis em água Poly {[2,5-bis(2-(N,N-diethylamino)ethoxy) -1,4 -phenylene]-alt-1,4-phenylene} e o Poly [(2,5-bis (2 - (N,N - diethylammonium bromide) ethoxy) - 1,4 -phenylene) - alt - 1,4-phenylene]. O polímero MEH-PPV foi dissolvido nos solventes orgânicos clorofórmio e bromofórmio, já os outros dois polímeros, em água destilada e solução de HCI 1M. As amostras foram preparadas em várias concentrações e irradiadas com doses que variaram desde 0,01 Gy, sendo que cada amostra foi irradiada com apenas uma dose. Os resultados foram avaliados com técnicas espectroscópicas, sendo elas, espectroscopia de absorção óptica UV-visível e espectroscopia de fluorescência. Foi avaliada a alteração na posição do pico principal de absorção óptica com a dose absorvida pelas amostras. Como resultado principal, observou-se que os polímeros solúveis em água não apresentam alteração espectral após serem irradiados. Não sendo interessante para aplicação dosimétrica. Já para as amostras do polímero MEH-PPV diluídas em bromofórmio apresentaram alta sensibilidade para doses inferiores a 1 Gy, e apresentaram certa linearidade com a dose recebida (fator importante para aplicação dosimétrica). Para as amostras em clorofórmio, não foi observado deslocamento significativo do escpectro de absorção para doses inferiores a 1 Gy. No entanto para doses de 1 Gy à 90 Gy, o comportamento observado pode ser descrito por duas regiões lineares: uma com maior inclinação da reta para doses até cerca 30 Gy, e outro com inclinação da reta menor para doses entre 30 Gy e 90 Gy. O comportamento linear, assim como a inclinação da reta, do deslocamento da posição... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The subject of this work is the investigation of gamma radition interaction with tree polymers: the polymer Poli(2-metóxi, 5-(2'-etil-hexilóx)-1,4- fenileno vinileno) (MEH-PPV)n e os polímeros solúveis em água Poly {[2,5-bis(2-(N,N-diethylamino)ethoxy) -1,4 -phenylene]-alt-1,4-phenylene} e o Poly [(2,5-bis (2 - (N,N - diethylammonium bromide) ethoxy) - 1,4 -phenylene) - alt - 1,4-phenylene]. The MEH-PPV polymer was dissolved in organic solvents, choloroform and bromoform, the other two polymers in distilled water and 1 M aqueous HCI solution. The samples were prepared at various concentrations and irradiated with doses ranging from 0.01 Gy to 90 Gy. The results were evaluated by spectroscopic techniques, which were, UV-visible absorption spectroscopy and fluorescence spectroscopy. They were evaluated the changes in the position of main optical absorption peak with the dose absorbed by the samples. As main result, it was observed that water-soluble polymers did not show spectral change after being irradiated. For dosimetric application this results are not interesting. For the MEH-PPV polymer samples diluted in bromoform presented highly sensitive to doses below 1 Gy, and showed some linearity with the dose received. For samples in chloroform, doses below 1 Gy did not showed significant shift in the absorption spectra. However, the samples irradiated with doses from 1 Gy to 90 Gy, the behavior can be described by two linear regions: one with a higher slope for doses up to about 30 Gy, and another with a lower slope for doses between 30 Gy and 90 Gy. A greater slope to doses up to about 30 Gy, and another with lower slope to doses between 30 and 90 Gy. The linear behavior and the slope of the main peak position is a important factor for dosimetric application. At the same time, a study of stability of the samples was performed. It was observed that the MEH-PPV samples in bromoform... (Complete abstract click electronic access below) / Orientador: Carlos Frederico de Oliveira Graeff / Coorientador: Marco Antonio Rodrigues Fernandes / Banca: Armando Beltran Flors / Banca: Antonio Ricardo Zanatta / O programa de Pós graduação em Ciência e Tecnologia de Materiais, PosMat, tem carater institucional e integra as atividades de pesquisa em materiais de diversos campi da Unesp / Mestre
19

Estudo de propriedades dosimétricas utilizando polímero organometálico em solução /

Fernandes, David Moreira. January 2012 (has links)
Orientador: Carlos Frederico de Oliveira Graeff / Coorientador: Erika Soares Bronze-Uhle / Banca: Francisco Eduardo Gontijo Guimarães / Banca: Marco Antonio Rodrigues Fernandes / O Programa de Pós Graduação em Ciência e Tecnologia de Materiais, PosMat, tem carater institucional e integra as atividades de pesquisa em materiais de diversos campi / Resumo: Este trabalho teve como objetivo estudar as características dosimétricas do polímero "poly-[1,1-bis(ethynyl)-4,4-bipheny(bis-tributylphosphine)Pt(11)]" (Pt-DEBP) frente à radiação gama. Para realização dos experimentos dissolveu-se o polímero Pt-DEBP, contendo dez unidades monoméricas, em solventes orgânicos - clorofórmio e totueno. As amostras foram irradiadas em quatro concentrações (0,0500; 0,0375; 0,0250; 0,0113 mg/mL) e em duplicatas, com doses que variaram de 1 a 90 Gy. Os resultados foram avaliados com base em técnicas espectroscópias, como a espectroscopia de absorção óptica (UV-VIs), fluorescência (emissão), fluorescência com resolução temporal (FRT) e infravermelho com transformada de Fourier (FTIR). Para soluções de Pt-DEBP em clorofórmio, nota-se uma alteração na posição da banca principal (л-л *) de absorção óptica para menores comprimentos de onda (blue-shift), aliado a uma diminuição da intensidade de absorção, á medida em que se aumenta a dose de radiação. Na espectroscopia de fluorescência, observou-se um deslocamento para maiores comprimentos de onda (red-shift) aliado a um aumento de intensidade na banda de emissão com aumento da dose de radiação. Experimentos de FRT, das amostras irradiadas em clorofórmio indicam a presença de um novo centro emissor. Os espectros de infravermelho com transformada de Fourier (FTIR) comprovam a entrada de cloro na cadeia polimérica, justificando o blue-shift obervado nos espectros de absorção e o novo centro emissor responsável pela alteração nos espectros de emissão. Além disso, foi analisado o comportamento linear dos resultados obtidos nos estudos de absorção e fluorescência, tomando como base a relação entre comprimento de onda máxima de absorção com a dose e, para o segundo caso, a relação entre... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This work aimed to study the dosimetric characteristics of the polymer of the polymer"poly-[1,1-bis (ethynyl) -4,4 biphenyl (bis-tributylphosphine) Pt (II)]" (Pt-DEBP) compared to radiation gamma. The Pt-DEBP polymer, containing ten monomer units, was then dissolved in organic solvents as chloroform and toluene. The samples were irradiated at four concentrations (0.0500, 0.250, 0.0113 mg / mL) in duplicate, with radiation doses ranging from 1 to 90 Gy. The results were evaluated based on spectroscopic techniques such as optical absorption spectroscopy (UV-Vis), fluorescence (emission), time resolved fluorescence (FRT) and Fourier transform infrared (FTIR). For DEBP-Pt solutions in chloroform, there is a shift in the position of the main optical absorption band (л-л *) to lower wavelength (blue-shift), allied to a decreasing absorption intensify with increasing radiation dose. In fluorescence spectroscopy, there was a shift to longer wavelengths (red-shift) allied to an increasing emission intensify with increasing radition dose. FRT experiments on irradiated samples dissolved in chloroform indicated the presence of a new emitter center. FTRI spectra show the incorporation of chlorine in polymer chain, justifying the blue-shift observed in the absorption spectra and the new emission center. In addition, the behavior of linear results in the aborption and fluorescence studies was investigated based on the relationship between the wavelength of maximum absorption/emission and the radiation dose. For both cases, a linear behavior was observed in relation to the sample concentration. Repeatability and stability tests were also performed. For the samples dissolved in tolluene, there was no significant shift of the spectrum of absorption or fluorescence for all doses. The results show that the Pt-DEBP polymer dissolved in chloroform can be used as a dosimer for y-ray doses between... (Complete abstract click electronic access below) / Mestre
20

Estudo de propriedades dosimétricas utilizando polímero organometálico em solução

Fernandes, David Moreira [UNESP] 30 March 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:30:18Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-03-30Bitstream added on 2014-06-13T20:40:11Z : No. of bitstreams: 1 fernandes_dm_me_bauru.pdf: 957024 bytes, checksum: 166e807e8c28852f41e7733849398194 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este trabalho teve como objetivo estudar as características dosimétricas do polímero poly-[1,1-bis(ethynyl)-4,4-bipheny(bis-tributylphosphine)Pt(11)] (Pt-DEBP) frente à radiação gama. Para realização dos experimentos dissolveu-se o polímero Pt-DEBP, contendo dez unidades monoméricas, em solventes orgânicos - clorofórmio e totueno. As amostras foram irradiadas em quatro concentrações (0,0500; 0,0375; 0,0250; 0,0113 mg/mL) e em duplicatas, com doses que variaram de 1 a 90 Gy. Os resultados foram avaliados com base em técnicas espectroscópias, como a espectroscopia de absorção óptica (UV-VIs), fluorescência (emissão), fluorescência com resolução temporal (FRT) e infravermelho com transformada de Fourier (FTIR). Para soluções de Pt-DEBP em clorofórmio, nota-se uma alteração na posição da banca principal (л-л *) de absorção óptica para menores comprimentos de onda (blue-shift), aliado a uma diminuição da intensidade de absorção, á medida em que se aumenta a dose de radiação. Na espectroscopia de fluorescência, observou-se um deslocamento para maiores comprimentos de onda (red-shift) aliado a um aumento de intensidade na banda de emissão com aumento da dose de radiação. Experimentos de FRT, das amostras irradiadas em clorofórmio indicam a presença de um novo centro emissor. Os espectros de infravermelho com transformada de Fourier (FTIR) comprovam a entrada de cloro na cadeia polimérica, justificando o blue-shift obervado nos espectros de absorção e o novo centro emissor responsável pela alteração nos espectros de emissão. Além disso, foi analisado o comportamento linear dos resultados obtidos nos estudos de absorção e fluorescência, tomando como base a relação entre comprimento de onda máxima de absorção com a dose e, para o segundo caso, a relação entre... / This work aimed to study the dosimetric characteristics of the polymer of the polymerpoly-[1,1-bis (ethynyl) -4,4 biphenyl (bis-tributylphosphine) Pt (II)] (Pt-DEBP) compared to radiation gamma. The Pt-DEBP polymer, containing ten monomer units, was then dissolved in organic solvents as chloroform and toluene. The samples were irradiated at four concentrations (0.0500, 0.250, 0.0113 mg / mL) in duplicate, with radiation doses ranging from 1 to 90 Gy. The results were evaluated based on spectroscopic techniques such as optical absorption spectroscopy (UV-Vis), fluorescence (emission), time resolved fluorescence (FRT) and Fourier transform infrared (FTIR). For DEBP-Pt solutions in chloroform, there is a shift in the position of the main optical absorption band (л-л *) to lower wavelength (blue-shift), allied to a decreasing absorption intensify with increasing radiation dose. In fluorescence spectroscopy, there was a shift to longer wavelengths (red-shift) allied to an increasing emission intensify with increasing radition dose. FRT experiments on irradiated samples dissolved in chloroform indicated the presence of a new emitter center. FTRI spectra show the incorporation of chlorine in polymer chain, justifying the blue-shift observed in the absorption spectra and the new emission center. In addition, the behavior of linear results in the aborption and fluorescence studies was investigated based on the relationship between the wavelength of maximum absorption/emission and the radiation dose. For both cases, a linear behavior was observed in relation to the sample concentration. Repeatability and stability tests were also performed. For the samples dissolved in tolluene, there was no significant shift of the spectrum of absorption or fluorescence for all doses. The results show that the Pt-DEBP polymer dissolved in chloroform can be used as a dosimer for y-ray doses between... (Complete abstract click electronic access below)

Page generated in 0.0937 seconds