• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 99
  • 10
  • 10
  • 10
  • 10
  • 8
  • 2
  • 2
  • Tagged with
  • 102
  • 102
  • 56
  • 54
  • 48
  • 20
  • 18
  • 16
  • 15
  • 13
  • 11
  • 11
  • 10
  • 10
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Comparação entre a imagem radiografica interproximal convencional e a digital direta na detecção de cáries proximais /

Araujo, Elaine Aparecida Félix de. January 2001 (has links)
Orientador: Julio Cezar de Melo Castilho / Banca: Claudio de Freitas / Banca: Luiz Cesarr de Moraes / Resumo: O objetivo neste trabalho foi o de avaliar a acurâcia na detecção de cáries proximais comparando a imagem digital e a imagem digital modificada brilho e contraste com os filmes Ektaspeed Plus e INSIGHT. Foram radiografados 52 pré-molares humanos extraídos e submetidos à idêntica padronização geométrica e condições de exposição. Usando uma escala de confiança com seis escores, quatro observadores, determinaram a ausência ou presença de cárie por quatro modalidades de imagem: a) filme Ektaspeed Plus; b) filme INSIGHT; c) digital direta; d) digital com modificação de brilho e contraste. O padrão real foi determinado pela análise microscópica das secções. Com os valores obtidos foi gerada uma curva ROC, avaliando a sensibilidade e especificidade dos métodos e com o teste estatístico Kappa de Cohen foi obtida a concordância inter observadores. Os resultados mostraram diferenças insignificantes entre a imagem digital e a radiográfica convencional (P>005) / Abstract: The purpose this study was to evaluate the accuracy of proximal caries detectíon comparing enhanced and unenhanced Sidexis CCD-based digital image with Ektaspeed Plus and lnsight films. Fifty-two extracted teeth posterior were imaged under identical standardized geometric and exposure condítions. Four observes, using six point confidence scale, rated 104 proximal surfaces for the presence or absence of carious lesions by means of four image modalities: a) Ektaspeed Plus films; b) INSIGHT films; c) unenhanced Sidexis displays; d) obsever enhanced. The real pattern was determined by microscopy analysis of sections. Receiver Operating Characteristic curves were generated analyzed with Kappa the according interobservers. The results indicated that there wasn't significant difference between unenhanced Sidexis and film images (P >0,05) / Mestre
72

Comparação entre imagens digitais diretas e laser de diodo na detecção de cáries proximais e oclusais /

Araujo, Elaine Aparecida Félix de. January 2004 (has links)
Orientador: Julio Cezar de Melo Castilho / Banca: Solange Maria de Almeida / Banca: Claudio Costa / Banca: Mari Elí Leonelli de Moraes / Banca: Ana Paula Martins Gomes / Resumo: O objetivo neste trabalho foi avaliar a acurácia na detecção de cáries proximais e oclusais comparando a imagem digital com o laser de diodo. Foram avaliados 33 pré-molares e 33 molares humanos extraídos e submetidos à idêntica padronização geométrica. Usando uma escala de confiança com cinco escores, quatro observadores determinaram a ausência ou presença de cárie por três sistemas auxiliares de diagnóstico: a) exame da imagem do Visualix; b) exame da imagem do RVG; c) exame utilizando o DIAGNOdent. O padrão ouro foi determinado pela análise histológica das secções. Com os valores obtidos foi gerada uma curva ROC e realizado o teste Kappa que determinou a concordância intra e ínterobservadores. Os resultados indicaram que as imagens digitais foram melhores na detecção de cáries proxímais que o laser DIAGNOdent e semelhantes na detecção de cáries oclusais / Abstract : The purpose of this study was to evaluate the accuracy of approximal and occlusal caries detection comparing Visualix and RVG CCD-based digital image with laser DIAGNOdent Sixty-six extracted posterior teeth were imaged under identical standardized geometric and exposure conditions. Four examiners, using five point confidence scale, rated 132 proximal and 66 occlusal surfaces for the presence or absence of carious lesions by means of three diagnostic systems: a) Visualix; b) RVG; c) DIAGNOdent. The gold standard was determined by microscopy analysis of sections. Receiver Operating Characteristic curves were generated analyzed with Kappa the according intra and interexaminers. The results indicated that digital images were better to detection approximal caries than laser Diagnodent and similar to occlusal caries / Doutor
73

Influência do laser de baixa intensidade na movimentação ortodôntica - avaliação clínica e radiográfica / Influence of low-level laser irradiation on orthodontic movement clinical and radiographic evaluation

Suelen Cristina da Costa Pereira 12 December 2014 (has links)
Este estudo é um ensaio clínico randomizado duplo-cego que avaliou a influência do laser de baixa intensidade (LBI) na movimentação ortodôntica de caninos superiores e inferiores, comparando-os aos caninos contralaterais não irradiados (controle). Foram selecionados 11 pacientes, portadores de má oclusão de Classe I com indicação de extração dos primeiros pré-molares superiores e inferiores. O laser infravermelho de baixa intensidade foi aplicado após a ativação da retração inicial dos caninos, realizada através de mola NiTi com uma força de 150g. A aplicação do laser foi realizada em 10 pontos (5 por vestibular e 5 por lingual) nos caninos superiores e inferiores, utilizando o seguinte protocolo, em dose única mensal: canino inferior por vestibular e lingual e canino superior por vestibular Comprimento de onda de 780nm; Potência de 40mW; densidade de energia de 10J/cm2; 10 segundos por ponto; energia por ponto de 0,4J, uma energia total de aplicação de 4J para o canino inferior e 2J por vestibular dos caninos superiores e para o canino superior por palatino o protocolo foi - Potência de 70mW; densidade de energia de 35J/cm2; 20 segundos por ponto; 1,4J de energia por ponto, energia total de 7J por palatino e total de 9J para o canino superior. A retração durou 3 meses, num total de 3 aplicações de laser. Para mensuração da quantidade de movimentação dos caninos retraídos, medições clínicas mensais foram realizadas com paquímetro digital, logo após as extrações dentárias e antes de cada aplicação do laser. Para comparação da velocidade da movimentação ortodôntica entre os lados irradiado e não irradiado nos três períodos avaliados, foi empregada a Análise de Variância a um critério de medidas repetidas, seguida do Teste de Tukey. Para verificação da integridade tecidual, foram efetuadas radiografias periapicais iniciais e finais dos caninos retraídos, nas quais foram avaliados uma possível reabsorção na crista alveolar, por meio da distância da crista óssea alveolar até a junção cementoesmalte e os níveis de reabsorção radicular, por meio do índice de Levander e Malmgreen. Para isto, foi empregado o teste não paramétrico de Wilcoxon. Em todos os testes adotou-se nível de significância de 5%. Os resultados demonstraram que não houve diferença estatisticamente significante na velocidade de retração dos caninos irradiados comparados aos não irradiados, em nenhum dos períodos avaliados. Em relação à influência do LBI nos níveis de reabsorções radiculares e ósseas, não foram encontradas diferenças significantes entre os grupos estudados. Concluiu-se assim que o LBI, no protocolo utilizado, não foi eficiente na aceleração da movimentação dentária e não promoveu danos aos tecidos de suporte do dente. / This study is a double-blind randomized clinical trial that evaluated the influence of low-intensity laser on orthodontic movement of upper and lower canine teeth, compared to the non- irradiated contralateral canines (control). Eleven patients with Class I malocclusion with indication of extraction of the first upper and lower premolars were selected. The infrared low-level laser was applied after the activation of initial retraction of the canine teeth, performed with NiTi coil springs with force of 150g. The laser application was performed in 10 points (5 buccal and 5 lingual) in the upper and lower canines, using the following protocol, in an only monthly dose: Lower canine buccal and lingual and upper canine buccal 780 nm wavelength; 40mW power; an energy density of 10 J/cm2; 10 seconds per point; energy per point 0,4J, a total energy of 4J applying to the lower canine and 2J the buccal of the upper canines and upper canine palatally - 70mW of power; an energy density of 35J/cm2; 20 seconds per point; 1,4J energy per point, the total energy 7J and total 9J to the upper canine. The retraction lasted three months, a total of three laser applications. To measure the amount of movement of canines retracted, monthly clinical measurements were made with a digital caliper (Mitutoyo - Japan), after tooth extractions and before each laser application. To compare the speed of orthodontic tooth movement between the irradiated and non- irradiated sides at the three movement stages, repeated measures one-way analysis of variance was used, followed by the Tukey test. For evaluation of tissue integrity, initial and final periapical radiographs of retracted canines were obtained, to evaluate a possible alveolar crest resorption by assessment of the distance from the alveolar bone crest to the cementoenamel junction, as well as the level of root resorption by the Levander and Malmgreen index, which was evaluated only on retracted canines. The nonparametric Wilcoxon test was applied for that purpose. In all tests we adopted a significance level of 5%. The results showed no statistically significant difference between the amount of retraction of the irradiated canines compared to the nonirradiated ones, in all evaluated periods. Regarding the influence of LLL in the levels of root and bone resorption, no significant differences between groups were found. It was therefore concluded that LLL in the protocol used was not effective in the acceleration of tooth movement and did not cause damage to the supporting tissues of the tooth.
74

Estudo retrospectivo da presença de reabsorção dentária em cães domésticos (Canis lupus familiaris) e suas correlações / Retrospective study on the presence of tooth resorption in domestic dogs (Canis lupus familiaris) and its correlations

Souza, Naiá de Carvalho de 22 June 2018 (has links)
Objetivou-se realizar um estudo retrospectivo sobre a frequência de cães acometidos pela reabsorção dentária (RD) atendidos no Laboratório de Odontologia Comparada da Faculdade de Medicina Veterinária e Zootecnia da Universidade de São Paulo, no período de 2006 a 2017, correlacionando com características como raça, idade, sexo, doenças orais concomitantes, hábito alimentar, comportamento mastigatório, histórico dental e sinais clínicos relacionados a dor, bem como, relatar estatisticamente os grupos dentários frequentemente acometidos, porções dentárias mais afetadas, aspectos radiográficos e extensão da reabsorção de acordo com a classificação determinada pelo American Veterinary Dental College (AVDC). Os dados avaliados procederam de 2.364 prontuários contendo fichas de consulta e de tratamento, além da análise de 1.122 registros radiográficos. Constatou-se que a prevalência geral da RD em cães foi de 8,7% e o ano mais frequente foi 2016 com 21,2%. Os pré-molares mandibulares e os maxilares foram significativamente mais afetados (37,3% e 38,1% respectivamente) e a porção radicular apresentou-se mais acometida (60,5%). As lesões do tipo 1 foram significativamente mais frequentes (53,2%) que as lesões do tipo 2 (27,9%) e tipo 3 (8,1%). Não houve lesões classificadas no estágio 1. Os estágios da reabsorção dentária mais frequentes foram o RD3 com 34,3% e o RD2 com 29,5%. Os estágios 4a, 4b e 4c representaram respectivamente 3,3%, 1,8% e 12,8%. No estágio 5, detectou-se apenas fragmentos de raiz em estágio avançado da reabsorção (2,3%). A reabsorção dentária foi associada estatisticamente com os cães de idades avançadas (10 e 13 anos com 14,6% cada). Não houve diferença significativa entre a frequência de machos e fêmeas, mas, a frequência de cães castrados (42,3%) foi significativamente menor do que a de não castrados (57,7%). A doença periodontal mostrou-se significativamente associada à reabsorção dentária (84,0%), seguida das fraturas dentárias (20,9%). Os cães acometidos pela RD alimentavam-se somente de ração (90,5%), premium ou super premium (86,6%). A maioria dos cães apresentaram-se assintomáticos no pré-operatório (82,0%) e sem alteração do comportamento no pós-operatório (39,3%). O tratamento de escolha para 66,5% dos casos foi a extração dentária. Concluiu-se que: a reabsorção inflamatória externa ou reabsorção do tipo 1, mostrou-se mais frequente quando comparada com a reabsorção de substituição externa (tipo 2). Sugere-se que boa parte da reabsorção dentária dos cães avaliados nesse estudo, esteja diretamente relacionada com processos inflamatórios desencadeados pela doença periodontal, uma vez que, evidenciou-se correlação estatística significativa entre a reabsorção dentária e a doença periodontal. / The objective of this study was to conduct a retrospective study on the frequency of dogs affected by tooth resorption attended at the Laboratory of Comparative Dentistry of the Faculty of Veterinary Medicine and Animal Science of the University of São Paulo from 2016 to 2017, correlating with characteristics such as race, age, sex, concomitant oral diseases, eating habits, masticatory behavior, dental history and clinical signs related to pain, as well as, statistically reporting the frequently affected dental groups, most affected dental portions, radiographic aspects and extent of resorption according to the classification determined by the American Veterinary Dental College (AVDC). The data evaluated came from 2,364 medical records containing records of consultation and treatment, in addition to the analysis of 1,122 radiographic records. It was found that the overall prevalence of tooth resorption in dogs was 8.7% and the most frequent year was 2016 with 21.2%. The mandibular and maxillary premolars were significantly more affected (37.3% and 38.1%, respectively) as well as the root portion (60.5%). Type 1 lesions were significantly more frequent (53.2%) than type 2 (27.9%) and type 3 (8.1%) lesions. There were no lesions classified in stage 1. The most frequent stages of tooth resorption were E3 with 34.3% and E2 with 29.5%. Stages 4a, 4b and 4c represented 3.3%, 1.8% and 12.8%, respectively. In stage 5, only root fragments were detected at an advanced stage of reabsorption (2.3%). Dental resorption was statistically associated with dogs at advanced ages (10 and 13 years old with 14.6% each). There was no significant difference between the frequency of males and females, but the frequency of castrated dogs (42.3%) was significantly lower than that of non-castrated dogs (57.7%). Periodontal disease was significantly associated with tooth resorption (84.0%), followed by dental fractures (20.9%). The dogs affected by tooth resorption were only fed commercial food (90.5%), premium or super premium (86.6%). Most of the dogs were asymptomatic in the preoperative period (82.0%) and no change in postoperative behavior (39.3%). The treatment of choice for 66.5% of the cases was dental extraction. It was concluded that: The external inflammatory resorption or type 1, was more frequent when compared to external replacement resorption (type 2). It is suggested that a good part of the dental resorption of the dogs evaluated in this study is directly related to inflammatory processes triggered by periodontal disease, since a significant statistical correlation between dental resorption and periodontal disease was evidenced.
75

"Análise por subtração radiográfica digital linear do tratamento de defeitos infra-ósseos humanos de 2 ou 3 paredes por meio de retalho de espessura total reposto associado ou não à proteína derivada da matriz do esmalte" / Linear radiographic digital subtraction analysis of treatment of human 2 or 3-wall intrabony defects by repositioned flap associated or not with enamel derivative matrix protein

Pasin, Ivan Munhoz 10 April 2006 (has links)
A Subtração Radiográfica Digital (SRD) vem sendo vastamente utilizada para inúmeros fins em Odontologia. Uma de suas aplicações é a avaliação do resultado radiográfico de procedimentos regenerativos. Este estudo avaliou radiograficamente defeitos infra-ósseos de 2 ou 3 paredes tratados com a proteína derivada da matriz do esmalte (PME) e/ou o retalho de espessura total reposto (RET). Foram selecionados 11 pacientes (3 ? / 8 ?) com periodontite crônica apresentando 2 ou mais defeitos. Antes da cirurgia e após 1 ano foram coletados os dados clínicos e radiográficos. Para a padronização radiográfica foi utilizado um posicionador modificado. Revelou-se os filmes numa processadora automática. As películas foram digitalizadas (500dpi/8bits) em um escaner (SprintScan 35 Plus - Polaroid). Através do programa AxioVision v 3.0 (Carl Zeiss) mediu-se as distâncias da JEC à crista óssea (CO), ao fundo do defeito (FD). Para criar uma escala milimétrica e calibrar a mensuração foi utilizada uma tela quadriculada (2 x 2 mm). As porcentagens de mudança óssea (MO) também foram calculadas. Os resultados mostraram perda da CO de 1,8 mm para PME (MO = -20,93%), revelando diferença estatística neste grupo (p<0,02), e de 0,9 mm para RET (MO = -10,71%), sem diferença entre os grupos. Observou-se maior preenchimento do FD em RET (1,1 mm; MO = 8,14%) do que em PME (-0,6 mm; MO = -3,92%), com diferença entre os grupos (p<0,01). Dentro das limitações deste estudo, conclui-se que através da análise por SRD linear o tratamento convencional de defeitos infra-ósseos humanos promoveu melhores resultados quando comparado à aplicação da PME. / Digital Subtraction Radiographic (DSR) has been widely used for several purposes in Dentistry. Among them is the radiographic evaluation of the results of regenerative procedures. This study evaluated radiographically 2 and 3-wall infra-bony defects which were treated with matrix derivative enamel protein (PME) and/or repositioned flap (RET). Eleven patients (3 ? / 8 ?) with chronic periodontitis were selected, presenting 2 or more defects. Clinical and radiographic data were collected before surgery. A modified filmholder was used to take standardized radiographs. X-ray were developed using an automatic machine. The films were digitized (500dpi/8bits) with the scanner SprintScan 35 Plus (Polaroid). The software AxioVision v 3.0 (Carl Zeiss) was used to measure the distances from the JEC to the alveolar crest (CO), to the bottom of the defect (FD). A grid (2 x 2 mm) was used to establish a milimetric scale after calibration. The amount of bone changes (MO) was also calculated. Results have shown loss of bone at the CO of 1,8 mm (PME) (MO = -20,93%), showing statistic significance (p<0,02), and of 0,9 mm to RET group (MO = -10,71%). No significant differences could be observed when groups were compared. A better fill was observed in the RET group (1,1 mm; MO = 8,14%) than in the PME group (-0,6 mm; MO = -3,92%), showing statistical significance between groups (p<0,01). In conclusion, radiographic analysis has shown that conventional treatment of human intra-bony defects promotes better results when compared to the application of PME.
76

"Análise por subtração radiográfica digital linear do tratamento de defeitos infra-ósseos humanos de 2 ou 3 paredes por meio de retalho de espessura total reposto associado ou não à proteína derivada da matriz do esmalte" / Linear radiographic digital subtraction analysis of treatment of human 2 or 3-wall intrabony defects by repositioned flap associated or not with enamel derivative matrix protein

Ivan Munhoz Pasin 10 April 2006 (has links)
A Subtração Radiográfica Digital (SRD) vem sendo vastamente utilizada para inúmeros fins em Odontologia. Uma de suas aplicações é a avaliação do resultado radiográfico de procedimentos regenerativos. Este estudo avaliou radiograficamente defeitos infra-ósseos de 2 ou 3 paredes tratados com a proteína derivada da matriz do esmalte (PME) e/ou o retalho de espessura total reposto (RET). Foram selecionados 11 pacientes (3 ? / 8 ?) com periodontite crônica apresentando 2 ou mais defeitos. Antes da cirurgia e após 1 ano foram coletados os dados clínicos e radiográficos. Para a padronização radiográfica foi utilizado um posicionador modificado. Revelou-se os filmes numa processadora automática. As películas foram digitalizadas (500dpi/8bits) em um escaner (SprintScan 35 Plus - Polaroid). Através do programa AxioVision v 3.0 (Carl Zeiss) mediu-se as distâncias da JEC à crista óssea (CO), ao fundo do defeito (FD). Para criar uma escala milimétrica e calibrar a mensuração foi utilizada uma tela quadriculada (2 x 2 mm). As porcentagens de mudança óssea (MO) também foram calculadas. Os resultados mostraram perda da CO de 1,8 mm para PME (MO = -20,93%), revelando diferença estatística neste grupo (p<0,02), e de 0,9 mm para RET (MO = -10,71%), sem diferença entre os grupos. Observou-se maior preenchimento do FD em RET (1,1 mm; MO = 8,14%) do que em PME (-0,6 mm; MO = -3,92%), com diferença entre os grupos (p<0,01). Dentro das limitações deste estudo, conclui-se que através da análise por SRD linear o tratamento convencional de defeitos infra-ósseos humanos promoveu melhores resultados quando comparado à aplicação da PME. / Digital Subtraction Radiographic (DSR) has been widely used for several purposes in Dentistry. Among them is the radiographic evaluation of the results of regenerative procedures. This study evaluated radiographically 2 and 3-wall infra-bony defects which were treated with matrix derivative enamel protein (PME) and/or repositioned flap (RET). Eleven patients (3 ? / 8 ?) with chronic periodontitis were selected, presenting 2 or more defects. Clinical and radiographic data were collected before surgery. A modified filmholder was used to take standardized radiographs. X-ray were developed using an automatic machine. The films were digitized (500dpi/8bits) with the scanner SprintScan 35 Plus (Polaroid). The software AxioVision v 3.0 (Carl Zeiss) was used to measure the distances from the JEC to the alveolar crest (CO), to the bottom of the defect (FD). A grid (2 x 2 mm) was used to establish a milimetric scale after calibration. The amount of bone changes (MO) was also calculated. Results have shown loss of bone at the CO of 1,8 mm (PME) (MO = -20,93%), showing statistic significance (p<0,02), and of 0,9 mm to RET group (MO = -10,71%). No significant differences could be observed when groups were compared. A better fill was observed in the RET group (1,1 mm; MO = 8,14%) than in the PME group (-0,6 mm; MO = -3,92%), showing statistical significance between groups (p<0,01). In conclusion, radiographic analysis has shown that conventional treatment of human intra-bony defects promotes better results when compared to the application of PME.
77

Análise comparativa entre o sistema digital Digora e a digitalização da radiografia convencional na avaliação da densidade radiográfica do processo de reparo alveolar

Silva, Jordan Lima da [UNESP] January 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:06Z (GMT). No. of bitstreams: 0 Previous issue date: 2005Bitstream added on 2014-06-13T20:21:53Z : No. of bitstreams: 1 silva_jl_dr_araca.pdf: 803850 bytes, checksum: a13420fee8c9eac95ae85dcbb9659489 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A película radiográfica é uma tecnologia que os cirurgiões-dentistas estão mais familiarizados estando confortáveis em termos da técnica e da interpretação. A radiografia digital é um avanço que está sendo adotado lentamente pelo cirugião-dentista, oferecendo algumas vantagens distintas sobre a película. O propósito deste estudo é comparar o sistema radiográfico digital Digora com a digitalização da radiografia convencional, avaliando a densidade radiográfica do processo de reparo alveolar na região de molares inferiores inclusos após exodontia em humanos. Os princípios e técnica para a exodontia foram padronizados assim como para a obtenção das imagens radiográficas. Imagem sugestiva de tecido ósseo mineralizado foi observada nos períodos de 60 e 90 dias, comparando os sistemas digital e convencional digitalizado. A estatística sugere perda nos valores da densidade, nos períodos estudados, para o sistema das radiografias convencionais digitalizadas em relação ao sistema Digora. Os resultados obtidos permitem concluir que a qualidade da imagem convencional digitalizada é menos precisa quando comparada a digital, para o acompanhamento do reparo ósseo pós-operatório. / Conventional radiographic film It is a technology that the surgeon-dentists more are made familiar being comfortable to in terms of the technique and the interpretation. The digital x-ray is an advance that is being adopted slowly for the dentistry. The digital image incorporates computer science in the captation, the exposition, the distinction, and the storage of the direct radiographic images. The digital image offers some distinct advantages on the film, but as all the emergent technology presents new different challenges and so that the users surpass them. The intention of this study was to evaluate through the radiograpic examination for the Digora system the radiographic density of the behavior of the fabric bone during the process of repair in the region of molar enclosed inferiors after exodontia in human beings. Standardized procedures had been used for the surgery of the patients as well as for the attainment of the radiographic images. Bone suggestive fabric image mineralized was observed in the periods of 60 and 90 days comparing the conventional and digital method. The gotten results allow to conclude that the quality of the digital conventional image is lower efficient than the digital one gotten directly for the accompaniment of the postoperative bone repair.
78

Avaliação objetiva da qualidade do filme Contrast® FV-58 em soluções frescas e degradadas

Carvalho, Fabiano Pachêco de 10 December 2009 (has links)
Made available in DSpace on 2015-05-14T12:56:05Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 1129487 bytes, checksum: 9b4bcacf33a745b3f606911583f777bb (MD5) Previous issue date: 2009-12-10 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The use of intraoral radiographs is quite common in daily practice of dentistry and the radiographic film has been the most used means of capture, disposal and storage of radiographic images. However, X-ray emission can produce deleterious biological effects. One of the easiest ways to reduce the radiation needed to produce radiographs is the use of more sensitive films. The choice of these films is essential, since the radiographic quality is not compromised. The films have different behaviors in the changing of the type of processing, concentration, temperature and state of degradation of processing solutions. This study aimed to evaluate the F-speed film DFL Contrast® FV-58 and compare it with the Kodak Insight® E/F speed film. The parameters studied were the sensitometric properties, the relative contrast and base plus fog density. These parameters were calculated from values of optical density and the sensitometric properties used also measures of radiation dose. In order to observe the behavior of the films in fresh and degraded solutions, a model of degradation was created that lasted four weeks. The quality parameters were measured at five different times and the results showed that the Contrast® film has sensitivity, contrast and base plus fog density significantly higher, whereas the values of latitude are minor. The relative contrast showed no significant difference between the types of film. The degradation time of processing solutions were not significant in the parameters studied. It was concluded that the claims of the manufacturer of the film Contrast® is correct and confirm the characteristics of film, the highest sensitivity and contrast that the Insight® film / A utilização de radiografias intrabucais é bastante comum na prática diária da Odontologia e o filme radiográfico tem sido o meio mais usado de captura, disposição e armazenamento das imagens radiográficas. Entretanto, as radiações X podem produzir efeitos biológicos deletérios. Uma das formas mais simples de reduzir a radiação que chega ao paciente é o uso de filmes mais sensíveis. A escolha desses filmes é essencial, desde que a qualidade radiográfica não seja prejudicada. Os filmes apresentam comportamentos diferentes frente às variações do tipo de processamento, concentração, temperatura e ao estado de degradação de soluções processadoras. O presente estudo teve como objetivo avaliar o filme DFL Contrast® FV-58 de sensibilidade F e compará-lo com o filme Kodak Insight®, de sensibilidade E/F. Os parâmetros estudados foram as propriedades sensitométricas, o contraste relativo e a densidade base e velamento. Esses parâmetros foram calculados a partir de valores de densidade óptica e o cálculo das propriedades sensitométricas também se utilizou de medidas de dose de radiação. Com a finalidade de observar o comportamento dos filmes em soluções frescas e degradadas, foi criado um modelo de degradação que durou quatro semanas. Os parâmetros de qualidade foram medidos em cinco tempos distintos e os resultados mostraram que o filme Contrast® possui valores de sensibilidade, contraste e densidade base e velamento significativamente maiores, enquanto os valores de latitude são menores. O contraste relativo não mostrou diferença significativa entre os tipos de filme. O tempo de degradação das soluções de processamento não mostrou significância nos parâmetros estudados. Concluiu-se que as alegações do fabricante do filme Contrast® estão corretas e confirmam as características desse filme, de maior sensibilidade e contraste que o filme Insight®.
79

Ativador elástico aberto de Klammt no tratamento da má oclusão de classe II divisão 1 /

Gonçalves, Renata de Cassia. January 2007 (has links)
Orientador: Ary dos Santos Pinto / Banca: Dirceu Barnabé Raveli / Banca: Gladys Cristina Dominguez Rodriguez / Resumo: O objetivo deste estudo prospectivo foi avaliar cefalometricamente as alterações esqueléticas e dento-alveolares naturais e induzidas pelo uso do Ativador Elástico Aberto de Klammt no tratamento da má oclusão de Classe II divisão 1. A amostra foi constituída por dois grupos pareados segundo gênero e idade: grupo experimental com 17 indivíduos (10 meninas e 7 meninos) que receberam tratamento com o aparelho de Klammt pelo período de 12 meses e grupo controle com 17 indivíduos não tratados (10 meninas e 7 meninos) observados durante um período de tempo similar. A média de idade inicial foi de 8,5 anos para ambos os grupos. Telerradiografias laterais foram obtidas no início e no final dos períodos de tratamento e observação. O grupo controle foi obtido a partir dos arquivos do Departamento de Clínica Infantil - Ortodontia, da Faculdade de Odontologia de Araraquara, Universidade Estadual Paulista - UNESP. As alterações observadas foram comparadas por meio do teste t de Student, a análise de variâncias foi realizada pelo teste de Levene e a relação entre altura do acrílico oclusal e alterações esqueléticas e dento-alveolares foi avaliada pelo coeficiente de correlação de Pearson. Os resultados demonstraram que o aparelho promoveu restrição dento-alveolar da maxila; aumento do comprimento mandibular total, comprimento do corpo mandibular e altura do ramo sem alterar o ângulo goníaco; aumento das alturas faciais anterior e posterior sem alterar o padrão facial de crescimento; melhora na relação maxilo-mandibular; verticalização dos incisivos superiores; manutenção da inclinação dos incisivos inferiores; redução do overjet e overbite; correção da relação molar de Classe II. O grupo controle mostrou aumento do comprimento maxilar; aumento do comprimento mandibular... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The objective of this prospective work was to evaluate cephalometrically the natural skeletal and dento-alveolar changes and those induced by use of the Klammt's Open Elastic Activator for class II division 1 malocclusion treatment. The sample consisted of two groups paired according to gender and age: treated group with 17 individuals (10 females and 7 males) that received treatment with the Klammt's appliance for period of 12 months and control group of 17 untreated subjects (10 females and 7 males) observed during a similar period of time. The initial mean age was 8.5 years old for the both groups. Lateral cephalometric radiographs were obtained at the beginning and end periods of treatment and observation. The control group was obtained from the files of the Department of Children's Clinic - Orthodontics at Araraquara Dental School, University of State of São Paulo - UNESP. The observed changes were compared by the student's t-test, the analysis of variance was carried out by Levene test and the relationship among the oclusal acrylic height and the skeletal and dento-alveolar changes was analyzed by Pearson's correlation coefficient. The results demonstrated that the Klammt's Open Elastic Activator produced dento-alveolar restriction of maxilla; increase in total mandibular length, body mandibular length, ramus height and no change gonial angle; increase in anterior and posterior face height and no change growth facial pattern; improvement in the maxillomandibular relationship; palatal tipping of the upper incisors; maintenance of the tipping of the lower incisors; reduction in the overjet and overbite, and correction of Class II molar relationship. The control group showed increase in maxillary length, increase in total mandibular length, body mandibular length, ramus height and no change... (Complete abstract, click electronic access below) / Mestre
80

Avaliação das alterações dos tecidos ao redor de implantes inseridos em diferentes níveis em relação à crista óssea: estudo clínico, radiográfico, e histométrico em cães

Pontes, Ana Emilia Farias [UNESP] 01 March 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:29Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-03-01Bitstream added on 2014-06-13T20:45:03Z : No. of bitstreams: 1 pontes_aef_dr_arafo.pdf: 2180778 bytes, checksum: 4f081c1f4701944b8a6da04a94fa99b3 (MD5) / O objetivo do presente estudo foi avaliar alterações ao redor de implantes inseridos em diferentes níveis em relação à crista óssea, e sob diferentes protocolos de restauração. Trinta e seis implantes foram inseridos nas mandíbulas edêntulas de 6 cães. Três implantes foram instalados por hemi-mandíbula, cada qual representativo de um grupo experimental. Estes foram determinados de acordo com a distância entre a junção implante-conector protético (JIC) e a crista óssea: Ao Nível (ao nível da crista óssea), Menos 1 (1mm apical à crista óssea), ou Menos 2 (2mm apical à crista óssea). Cada hemi-mandíbula foi submetida a um protocolo de restauração: convencional (prótese instalada 120 dias após a implantação) ou imediata (prótese instalada 24 horas após a implantação). Parâmetros clínicos, radiográficos, e histométricos foram avaliados após 90 dias de restauração, e os dados foram analisados estatisticamente (alfa=5%). A posição da margem do tecido mole (PTM) não foi influenciada pelo posicionamento apical da JIC; entretanto, sítios submetidos à restauração imediata tiveram a PTM significantemente mais coronal que os submetidos à restauração convencional (p=0,02, análise clínica). A reabsorção do rebordo não foi estatisticamente diferente entre os grupos (p>0,05, análise radiográfica). Menores quantidades de Perda Óssea Lateral (POL) foram observadas nos sítios restaurados imediatamente em comparação com os restaurados convencionamente (p=0,006, análise histométrica). Os presentes achados sugerem que o posicionamento apical da JIC não põe em risco a altura de tecidos periimplantares moles ou duros. Além disto, a restauração imediata foi benéfica para manter a PTM, e minimizar a POL. / The aim of the present study was to evaluate changes that occur around dental implants inserted in different levels in relation to crestal bone, under different restoration conditions. Thirty-six implants were inserted in the edentulous mandible of six dogs. Three implants were inserted per hemimandible, each one representing an experimental group according to the distance from the implant-abutment junction (IAJ) to the crestal bone: Bone Level (at crestal bone level), Minus 1 (1mm below crestal bone), or Minus 2 group (2mm below crestal bone). Each hemimandible was submitted to a restoration protocol: conventional (prothesis installed 120 days after implant placement) or immediate (prosthesis installed 24 hours after implant placement). Clinical, radiographic, and histometric parameters were evaluated after 90 days of restoration, and data was analyzed statistically (alpha=5%). The position of soft tissue margin (PSTM) was not influenced by the apical positioning of the IAJ; however, sites submitted to immediate restoration had the PSTM displayed significantly more coronally than those submitted to conventional restoration (p=0.02, clinical analysis). Ridge Loss was not statistically different among groups (p>0.05, radiographic analysis). Greater amounts of Lateral Bone Loss (LBL) were observed for conventionally than for immediately restored sites (p=0.006, histometric analysis). These findings suggest that the apical positioning of IAJ did not jeopardize the height of peri-implantar soft and hard tissues. Moreover, immediate restoration was beneficial to maintain the PSTM, and to minimize LBL.

Page generated in 0.2515 seconds