• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 17
  • 15
  • 2
  • 2
  • 1
  • Tagged with
  • 36
  • 36
  • 26
  • 16
  • 16
  • 15
  • 13
  • 11
  • 10
  • 10
  • 10
  • 10
  • 9
  • 9
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Estudo da viabilidade do emprego da técnica de subtração radiográfica digital em radiografias periapicais com registro a posteriori /

Assis, Afonso Celso Souza de. January 2010 (has links)
Orientador: Luiz Cesar de Moraes / Banca: Pedro Luiz de Carvalho / Banca: Cristiane Yumi Koga Ito / Resumo: Apesar de ser uma técnica limitada, a subtração digital é utilizada na Odontologia. A adição do computador e seus algoritmos para equalização de contraste e também correção geométrica, tornou possível a aplicação da subtração radiográfica digital (SRD), utilizando radiografias intrabucais. Neste estudo foi avaliada a viabilidade da utilização da subtração radiográfica digital pelo programa Regeemy - Image Registration and Mosaicking v.0.2.43-RCB (DPI-INPE, São José dos Campos, SP, Brazil) em radiografias periapicais digitalizadas e obtidas sem utilização de padronização rígida durante as exposições por meio de registro a posteriori. A seleção dos pontos de controle foram realizadas de forma automática e em quantidade múltipla pelo Reggemy. Esses pontos serviram como coordenadas a partir das quais o programa alinhou o par de imagens e gerou uma terceira imagem de acordo com a projeção geométrica da imagem de referência. Com o uso do Adobe Photoshop© foram selecionados os ROI das imagens utilizando guias e coordenadas. Depois de aplicados os testes estatísticos foi verificado que a metodologia do presente estudo não permite concluir que a subtração utilizando-se o programa Regeemy é inviável quando realizada sem padronização / Abstract: The digital subtraction has been widely used in dentistry. The addition of computer and its algorithms for equalization of contrast and geometric correction also made possible the application of radiographic digital subtraction (SRD) using intraoral radiographs. This study assessed the feasibility of using X-ray digital subtraction of the program Regeemy - Image Registration and mosaicking v.0.2.43-RCB (DPI-INPE, Sao Jose dos Campos, SP, Brazil) in periapical radiographs digitized and obtained without the use of standardized rigid during the exposures by registering the event. The selection of control points were performed automatically and in quantity by multiple Reggemy. These points were used as coordinates from which the program aligned the image pair and a third image generated according to the geometrical projection of the reference image. Using Adobe Photoshop ©, we selected the ROI of the images using guides and coordinates. After applying the statistical tests we can conclude that the methodology of this study does not suggest that the subtraction using the program Regeemy is feasible when performed without standardization. It is suggested further studies to evaluate the impact of subtraction radiography with no standardization in clinical diagnosis / Mestre
12

Avaliação da interface osso e implantes dentários em exames por imagem e suas implicações no diagnóstico

Vidor, Michele Machado January 2015 (has links)
Introdução: O desenvolvimento da radiologia digital e da tomografia computadorizada de feixe cônico (TCFC) permitiu aos profissionais diferentes formas de avaliação das imagens. Entretanto, frente a materiais metálicos, é observada a formação de artefatos tanto na imagem tomográfica, quanto nas radiografias digitais após a aplicação de filtros de processamento. Objetivo: Esta pesquisa objetivou investigar a interferência provocada por materiais metálicos na avaliação da interface osso/implante em radiografias periapicais convencional e digital, e em TCFC. Materiais e Métodos: Foram inseridos implantes de titânio em 74 blocos de costelas bovina frescas. Em 37, a inserção foi em íntima relação com as paredes ósseas (Grupo Controle-GC) e nos outros 37 com um espaço de 0.125 mm (Grupo Teste-GT). As radiografias periapicais foram realizadas com filme convencional e dois sistemas digitais de placa de fósforo. As imagens volumétricas foram adquiridas em dois equipamentos de TCFC. Nos sistemas digitais as imagens foram investigadas com e sem a utilização dos filtros e, nas tomografias, com diferentes protocolos de aquisição. Três examinadores treinados e cegados realizaram a avaliação utilizando uma escala Likert de cinco pontos. Foram utilizados testes de sensibilidade, especificidade e acurácia (área sob a curva ROC) e teste de concordância de Kendall (W). Resultados: Na avaliação radiográfica (ARTIGO I), foi observada maior acurácia do exame convencional e das imagens do sistema VistaScan com filtros Caries2 e Endo e do sistema Express com filtro Sharpen3 na detecção da justaposição entre osso e implante. Na avaliação tomográfica (ARTIGO II), somente as imagens do tomógrafo i-Cat com a resolução de voxel de 0.125mm não apresentaram diferença significativa com a radiografia convencional na acurácia diagnóstica. Conclusão: Na avaliação radiográfica da justaposição entre o osso e o implante, preferência deve ser dada às radiografias convencionais ou às digitais com filtros de realce (Caries2, Endo e Sharpen3). Em caso da existência de exames de TCFC com voxel 0.125 mm, tal avaliação também pode ser realizada. / Introduction: The development of digital radiology and computed tomography cone beam (CBCT) enabled professionals different possibilities of images evaluation. However, when metallic materials are present, artifacts formation can be observed in tomographic images and in digital radiography after processing fiters. Objective: This study investigated the interference caused by metallic materials in bone/implant interface evaluation with conventional and digital periapical radiographs, and CBCT. Materials and Methods: Titanium implants were placed into 74 fresh bovine ribs. In 37, the implants were in close relation with the bone walls (Control Group-CG) and the remaining 37 ribs preparations promoted a 0.125 mm space (Test Group-GT) .The periapical radiographs were taken with conventional film and digital photostimulable phosphor plate (PSP) system of two commercial brands. The volumetric images were acquired in two CBCT equipment. The digital images were investigated with and without the use of processing filters available and the tomographic with different acquisition protocol. Three trained and blinded examiners performed the evaluation using a five points Likert scale. Sensitivity, specificity and accuracy (area under the ROC curve) tests were used and Kendall´s coefficient of concordance (W). Results: In the radiographic evaluation (Article I), there was a higher accuracy to detect the juxtaposition between bone and implant with the conventional radiography and the images of VistaScan system using the Caries2 and Endo filters, and Express system with Sharpen3 filter. In the tomographic evaluation (Article II), only the images with 0.125mm of voxel resolution from i-Cat CBCT showed no significant difference with conventional radiography in the diagnostic accuracy. Conclusion: In radiographic evaluation of juxtaposition between bone and implant preference should be given to conventional radiographs or in digital radiographs to Caries2, Endo and Sharpen3 enhancement filters. In case of the existence of CBCT exams (voxel 0.125mm), such evaluation can also be performed.
13

Avaliação da interface osso e implantes dentários em exames por imagem e suas implicações no diagnóstico

Vidor, Michele Machado January 2015 (has links)
Introdução: O desenvolvimento da radiologia digital e da tomografia computadorizada de feixe cônico (TCFC) permitiu aos profissionais diferentes formas de avaliação das imagens. Entretanto, frente a materiais metálicos, é observada a formação de artefatos tanto na imagem tomográfica, quanto nas radiografias digitais após a aplicação de filtros de processamento. Objetivo: Esta pesquisa objetivou investigar a interferência provocada por materiais metálicos na avaliação da interface osso/implante em radiografias periapicais convencional e digital, e em TCFC. Materiais e Métodos: Foram inseridos implantes de titânio em 74 blocos de costelas bovina frescas. Em 37, a inserção foi em íntima relação com as paredes ósseas (Grupo Controle-GC) e nos outros 37 com um espaço de 0.125 mm (Grupo Teste-GT). As radiografias periapicais foram realizadas com filme convencional e dois sistemas digitais de placa de fósforo. As imagens volumétricas foram adquiridas em dois equipamentos de TCFC. Nos sistemas digitais as imagens foram investigadas com e sem a utilização dos filtros e, nas tomografias, com diferentes protocolos de aquisição. Três examinadores treinados e cegados realizaram a avaliação utilizando uma escala Likert de cinco pontos. Foram utilizados testes de sensibilidade, especificidade e acurácia (área sob a curva ROC) e teste de concordância de Kendall (W). Resultados: Na avaliação radiográfica (ARTIGO I), foi observada maior acurácia do exame convencional e das imagens do sistema VistaScan com filtros Caries2 e Endo e do sistema Express com filtro Sharpen3 na detecção da justaposição entre osso e implante. Na avaliação tomográfica (ARTIGO II), somente as imagens do tomógrafo i-Cat com a resolução de voxel de 0.125mm não apresentaram diferença significativa com a radiografia convencional na acurácia diagnóstica. Conclusão: Na avaliação radiográfica da justaposição entre o osso e o implante, preferência deve ser dada às radiografias convencionais ou às digitais com filtros de realce (Caries2, Endo e Sharpen3). Em caso da existência de exames de TCFC com voxel 0.125 mm, tal avaliação também pode ser realizada. / Introduction: The development of digital radiology and computed tomography cone beam (CBCT) enabled professionals different possibilities of images evaluation. However, when metallic materials are present, artifacts formation can be observed in tomographic images and in digital radiography after processing fiters. Objective: This study investigated the interference caused by metallic materials in bone/implant interface evaluation with conventional and digital periapical radiographs, and CBCT. Materials and Methods: Titanium implants were placed into 74 fresh bovine ribs. In 37, the implants were in close relation with the bone walls (Control Group-CG) and the remaining 37 ribs preparations promoted a 0.125 mm space (Test Group-GT) .The periapical radiographs were taken with conventional film and digital photostimulable phosphor plate (PSP) system of two commercial brands. The volumetric images were acquired in two CBCT equipment. The digital images were investigated with and without the use of processing filters available and the tomographic with different acquisition protocol. Three trained and blinded examiners performed the evaluation using a five points Likert scale. Sensitivity, specificity and accuracy (area under the ROC curve) tests were used and Kendall´s coefficient of concordance (W). Results: In the radiographic evaluation (Article I), there was a higher accuracy to detect the juxtaposition between bone and implant with the conventional radiography and the images of VistaScan system using the Caries2 and Endo filters, and Express system with Sharpen3 filter. In the tomographic evaluation (Article II), only the images with 0.125mm of voxel resolution from i-Cat CBCT showed no significant difference with conventional radiography in the diagnostic accuracy. Conclusion: In radiographic evaluation of juxtaposition between bone and implant preference should be given to conventional radiographs or in digital radiographs to Caries2, Endo and Sharpen3 enhancement filters. In case of the existence of CBCT exams (voxel 0.125mm), such evaluation can also be performed.
14

Detection of periimplant fenestration and dehiscence using CBCT - an in vitro study = Diagnóstico tomográfico de fenestração e deiscência peri-implantar - estudo in vitro / Diagnóstico tomográfico de fenestração e deiscência peri-implantar - estudo in vitro

Vaz, Sergio Lins de Azevedo, 1984- 22 August 2018 (has links)
Orientador: Francisco Haiter Neto / Tese (Doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-22T00:06:43Z (GMT). No. of bitstreams: 1 Vaz_SergioLinsdeAzevedo_D.pdf: 2097588 bytes, checksum: 48e378674d749eb9b8ea2a05042e21a4 (MD5) Previous issue date: 2013 / Resumo: O presente estudo se propôs a avaliar a influência do tamanho de voxel e giro de escaneamento na detecção tomográfica de fenestração e deiscência peri-implantar, além do uso de filtros de imagem na detecção da deiscência peri-implantar. Em fragmentos de costelas bovinas, foi criado defeitos que simulariam fenestração e deiscência peri-implantar após a instalação de 100 implantes de titânio. As imagens foram adquiridas no tomógrafo computadorizado de feixe cônico i-CAT Next Generation, empregando FOV de 8 x 8 cm e três protocolos: A- voxel de 0,2 mm, giro de escaneamento de 180°; B- voxel de 0,2 mm, giro de 360°; C- voxel de 0,12 mm, giro de 360°. Cinco filtros do programa XoranCat foram testados: Angio Sharpen High 5x5, Shadow, Sharpen 3×3, Sharpen Mild e Smooth. Três cirurgiões-dentistas radiologistas identificaram a presença ou ausência dos defeitos. Curvas ROC foram criadas e os valores de área sob a curva (Az) comparados utilizando a Análise de Variância (ANOVA), com teste post hoc de Bonferroni (alfa de 5%). O teste de McNemar foi utilizado para comparar imagens (originais e com filtros) versus padrão ouro, bem como imagens originais versus imagens com filtros. Os resultados mostraram diferenças estatisticamente significantes entre os valores de Az dos protocolos B e C em relação ao protocolo A (p < 0,01) para deiscência. Houve diferenças estatisticamente significantes (p < 0,01) entre as imagens originais e o filtro Shadow em relação ao padrão ouro, bem como entre todos os filtros testados em relação às imagens originais. Concluiu-se que os tamanhos de voxel testados não influenciaram no diagnóstico de ambos os defeitos, enquanto que o giro de escaneamento completo (360°) foi melhor para deiscência. Diante da maior dificuldade no diagnóstico tomográfico de deiscência peri-implantar, o uso dos filtros de imagem testados é aconselhado, com exceção do filtro Shadow / Abstract: This study set out an assessment of the effects of two voxel sizes and scan modes of cone-beam computed tomography (CBCT) in periimplant fenestration and dehiscence detection. It also aimed to investigate whether CBCT filters would enhance the diagnosis of periimplant dehiscence. One hundred titanium implants were placed in bovine ribs in which periimplant fenestration and dehiscence were simulated. The images were acquired using the i-CAT Next Generation CBCT unit, with a FOV of 8 x 8 cm and the following protocols: A- 0.2 mm voxel size half-scan (180°); B- 0.2 mm voxel size full-scan (360°); and C- 0.12 mm voxel size full-scan (360°). Five filters of the XoranCat software were tested: Angio Sharpen High 5x5, Shadow, Sharpen 3×3, Sharpen Mild and Smooth. Three oral radiologists performed a dynamic evaluation of the presence/absence of the defects and ROC curves were created. The values of the area under the curve (Az) were compared with ANOVA and Bonferroni post-hoc test. The significance level was adopted at 5%. The McNemar test was applied to perform two comparisons in order to identify disagreements. All the enhanced and the original images were compared with the gold-standard and the original images were compared to the enhanced ones. The protocol A had significantly lower Az values than those obtained with the protocols B and C (p < 0.01) for dehiscence. The original images and the Shadow filter were statistically different from the gold-standard (p < 0.01). All the enhanced images also had statistically significant differences from the original images (p < 0.01). In conclusion, the voxel sizes did not influence in periimplant fenestration and dehiscence detection but the full-scan (360°) performed better than the half-scan for dehiscence. The use of enhancement CBCT filters for dehiscence detection is advised, with the exception of the Shadow filter / Doutorado / Radiologia Odontologica / Doutor em Radiologia Odontológica
15

Quantitative ultrasonography in regional anesthesia. / CUHK electronic theses & dissertations collection

January 2009 (has links)
Li, Xiang. / Thesis (Ph.D.)--Chinese University of Hong Kong, 2009. / Includes bibliographical references (leaves 161-184). / Electronic reproduction. Hong Kong : Chinese University of Hong Kong, [2012] System requirements: Adobe Acrobat Reader. Available via World Wide Web. / Abstract and appendix also in Chinese.
16

Assessment of atherosclerosis by whole-body magnetic resonance angiography /

Hansen, Tomas, January 2007 (has links)
Diss. (sammanfattning) Uppsala : Univ., 2007. / Härtill 4 uppsatser.
17

An in vitro comparison of working length accuracy between a digital system and conventional film when vertical angulation of the object is variable

Christensen, Shane R. January 2009 (has links)
Thesis (M.S.D.)--Indiana University School of Dentistry, 2009. / Title from PDF t. p. (viewed Aug. 21, 2009) Advisor(s): Mychel Vail, Acting Chair of the Research Committee, Joseph Legan, Kenneth Spolnik, Susan L. Zunt, Edwin Parks. Curriculum vitae. Includes abstract. Includes bibliographical references (leaves 109-120).
18

Influência da presença de materiais metálicos na capacidade diagnóstica de diferentes métodos por imagem - radiografia convencional, radiografia digital e tomografia computadorizada de feixe cônico - investigação in vitro / Influence of the presence of metallic materials in the diagnostic ability of diverse imaging methods - conventional radiograph, digital radiograph and cone-beam computed tomography - in vitro reserach

Liedke, Gabriela Salatino January 2014 (has links)
O objetivo desta tese foi avaliar a interferência da presença de materiais metálicos na imagem radiográfica e tomográfica por meio da análise da adaptação marginal de restaurações e coroas metálicas. Esta investigação resultou em 3 artigos: uma revisão sistemática da literatura para identificar o estado da arte com relação ao uso dos métodos radiográficos; um estudo in vitro comparando o desempenho do filme radiográfico convencional e dos sistemas digitais VistaScan Dürr Dental, Digora Classic Soredex e Express Instrumentarium – com e sem o emprego de filtros para o pós processamento da imagem; e um estudo in vitro avaliando o processamento das imagens da TCFC – utilizando diferentes espessuras de reconstrução. Na revisão sistemática foram incluídos 14 estudos, sendo classificados de baixa ou moderada qualidade, de acordo com os critérios QUADAS de classificação. Na investigação radiográfica (artigo 2), os maiores valores de sensibilidade (0,67 0,83), especificidade (0,81 0,92) e acurácia (0,73 0,86) foram obtidos com radiografias convencionais e imagens digitais originais. Na avaliação tomográfica (artigo 3), os valores da aucROC variaram de 0,60 a 0,72, sendo que o limite inferior do intervalo de confiança mostrou-se abaixo ou muito próximo da linha de referencia. Frente aos resultados, conclui-se que imagens radiográficas originais (convencionais ou digitais) devem ser preferidas para a avaliação de dentes com restaurações metálicas. Quanto à TCFC, mesmo quando se aumenta a espessura de reconstrução da imagem e diminui-se o artefato, ainda assim não há melhora na acurácia do diagnóstico. / The aim of this thesis was to evaluate the interference of the presence of metallic materials on radiographic and tomographic image by assessing misfits tooth and restoration in metal-restored teeth. This investigation resulted in three articles: a systematic review of the literature to identify the state of the art on the use of radiographic methods; an in vitro study comparing the performance of conventional film and digital phosphor plate systems Vistascan Dürr Dental, Digora Classic Soredex and Instrumentarium Express – exported as original images and with the use of post processing filters; and an in vitro study evaluating the post-processing of CBCT images – using diverse reconstruction thicknesses. The systematic review retrived 14 studies, classified as low- / moderate quality based on QUADAS criteria. For radiographic evaluation (article II), higher sensitivity (0.67 0.83), specificity (0.81 0.92) and accuracy (0.73 0.86) values were obtained with conventional and digital original images. For tomographic evaluation (article III), mean aucROC ranged from 0.60 to 0.72, and the analysis of the 95% CI showed the lower bound of the curve bellow or very close to the reference line. Based on the results, it is concluded that original images (conventional or digital) should be preferred for the assessment of teeth with metal restorations. Considering CBCT images, even thought increased reconstruction thickness decreased perceived artifact, it did not improve diagnosis accuracy.
19

Estudo radiográfico digital e densitométrico em mandíbulas de suínos, submetidas a osteotomia com brocas de alta e baixa rotação, com refrigeração líquida

Monti, Lira Marcela [UNESP] 09 December 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:25:20Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-12-09Bitstream added on 2014-06-13T19:52:59Z : No. of bitstreams: 1 monti_lm_me_araca.pdf: 287560 bytes, checksum: 074e03765d9ead5baba4ea3ffcdf36ee (MD5) / Universidade Estadual Paulista (UNESP) / Avaliou-se, por meio de exames radiográficos digitais e densitométricos, a influência do tipo de instrumento rotatório para corte, no processo de reparação óssea após osteotomias em mandíbula de suíno em tempos controlados. Foram utilizados para o estudo oito suínos da raça Large White, com peso corpóreo inicial variando de 25 a 30 Kg. Dois cortes transversais do meio à base de mandíbula direita foram realizados, um por meio de instrumento rotatório de alta rotação e o outro pela ação da baixa rotação, ambos com irrigação líquida. Após períodos pré-estabelecidos (7, 28, 60 e 90 dias) os animais foram sacrificados e suas mandíbulas retiradas para estudos radiográficos digitais diretos e indiretos, pelo sistema DIGORA e ODR e de densitometria óptica por imagens radiográficas pelo sistema CROMOX. Nos períodos iniciais (7 e 28 dias) as densitometrias foram maiores na região das osteotomias realizadas com alta rotação e nos períodos finais (60 e 90 dias) as densitometrias foram maiores nas osteotomias feitas com baixa rotação, indicando uma melhor reparação óssea final quando do uso de baixa rotação. A análise qualitativa do processo de reparação foi feita pelo sistema ODR, que possibilitou a obtenção de imagens digitais tridimensionais e coloridas, permitindo comparação das espessuras ósseas com as de uma cunha de alumínio, evidenciando que aos sessenta dias a reparação óssea estava aparentemente completa. Os histogramas do DIGORA apontaram valores de médias de nível de cinza nas áreas de osteotomia, evidenciando uma maior quantidade de tons de cinza nas osteotomias de alta rotação nos primeiros tempos, e nas osteotomias com baixa-rotação nos tempos finais. / It was evaluated, through digital and densitometric radiographic exams, the influence of the type of rotating instrument for cut, in the process of bony repair after osteotomy in swine jaw in controlled times. They were used for the study eight Large White swines, with initial corporal weight varying from 25 to 30 Kg. Two traverse cuts of the middle to the base of right jaw were accomplished, one through rotating instrument of high rotation and the other for the action of the low rotation, both with liquid irrigation. After established periods (7, 28, 60 and 90 days) the animals were sacrificed and your mandibles retired for direct and indirect digital radiografic studies, for the DIGORA and ODR systems and of optical densitometry for radiographic images for the CROMOX system. In the initial periods (7 and 28 days) the densitometry were larger in osteotomy areas accomplished with high rotation and in the final periods (60 and 90 days) the densitometry were larger in the osteotomy done with low rotation, indicating a better final bony repair when of the use of low rotation. The qualitative analysis of the repair process was made by the ODR system, that made possible obtaining three-dimensional and colored digital images, allowing comparison of the bony thickness with the one of a wedge of aluminum, evidencing that to the sixty days the bony repair was apparently complete. The histograms of DIGORA pointed values of the averages of ash tones in the osteotomy areas, evidencing a larger amount of ash tones in the osteotomy of high rotation in the first times, and in the osteotomy with low-rotation in the final times.
20

Influência da presença de materiais metálicos na capacidade diagnóstica de diferentes métodos por imagem - radiografia convencional, radiografia digital e tomografia computadorizada de feixe cônico - investigação in vitro / Influence of the presence of metallic materials in the diagnostic ability of diverse imaging methods - conventional radiograph, digital radiograph and cone-beam computed tomography - in vitro reserach

Liedke, Gabriela Salatino January 2014 (has links)
O objetivo desta tese foi avaliar a interferência da presença de materiais metálicos na imagem radiográfica e tomográfica por meio da análise da adaptação marginal de restaurações e coroas metálicas. Esta investigação resultou em 3 artigos: uma revisão sistemática da literatura para identificar o estado da arte com relação ao uso dos métodos radiográficos; um estudo in vitro comparando o desempenho do filme radiográfico convencional e dos sistemas digitais VistaScan Dürr Dental, Digora Classic Soredex e Express Instrumentarium – com e sem o emprego de filtros para o pós processamento da imagem; e um estudo in vitro avaliando o processamento das imagens da TCFC – utilizando diferentes espessuras de reconstrução. Na revisão sistemática foram incluídos 14 estudos, sendo classificados de baixa ou moderada qualidade, de acordo com os critérios QUADAS de classificação. Na investigação radiográfica (artigo 2), os maiores valores de sensibilidade (0,67 0,83), especificidade (0,81 0,92) e acurácia (0,73 0,86) foram obtidos com radiografias convencionais e imagens digitais originais. Na avaliação tomográfica (artigo 3), os valores da aucROC variaram de 0,60 a 0,72, sendo que o limite inferior do intervalo de confiança mostrou-se abaixo ou muito próximo da linha de referencia. Frente aos resultados, conclui-se que imagens radiográficas originais (convencionais ou digitais) devem ser preferidas para a avaliação de dentes com restaurações metálicas. Quanto à TCFC, mesmo quando se aumenta a espessura de reconstrução da imagem e diminui-se o artefato, ainda assim não há melhora na acurácia do diagnóstico. / The aim of this thesis was to evaluate the interference of the presence of metallic materials on radiographic and tomographic image by assessing misfits tooth and restoration in metal-restored teeth. This investigation resulted in three articles: a systematic review of the literature to identify the state of the art on the use of radiographic methods; an in vitro study comparing the performance of conventional film and digital phosphor plate systems Vistascan Dürr Dental, Digora Classic Soredex and Instrumentarium Express – exported as original images and with the use of post processing filters; and an in vitro study evaluating the post-processing of CBCT images – using diverse reconstruction thicknesses. The systematic review retrived 14 studies, classified as low- / moderate quality based on QUADAS criteria. For radiographic evaluation (article II), higher sensitivity (0.67 0.83), specificity (0.81 0.92) and accuracy (0.73 0.86) values were obtained with conventional and digital original images. For tomographic evaluation (article III), mean aucROC ranged from 0.60 to 0.72, and the analysis of the 95% CI showed the lower bound of the curve bellow or very close to the reference line. Based on the results, it is concluded that original images (conventional or digital) should be preferred for the assessment of teeth with metal restorations. Considering CBCT images, even thought increased reconstruction thickness decreased perceived artifact, it did not improve diagnosis accuracy.

Page generated in 0.0707 seconds