Spelling suggestions: "subject:"radiography, Dental, 4digital."" "subject:"radiography, Dental, deigital.""
11 |
Subtração digital radiográfica: identificação precoce de perdas minerais em esmalteDotto, Gustavo Nogara [UNESP] 30 June 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:29:12Z (GMT). No. of bitstreams: 0
Previous issue date: 2003-06-30Bitstream added on 2014-06-13T19:38:20Z : No. of bitstreams: 1
dotto_gn_me_sjc.pdf: 1763625 bytes, checksum: f58c55befeddf132e0118ae4623007eb (MD5) / Neste estudo in vitro, avaliou-se a progressão da perda mineral causada pela aplicação de ácido clorídrico a 18% em esmalte proximal de dentes pré-molares humanos, utilizando imagens radiográficas digitais diretas e também a técnica de subtração digital de imagens, por meio da comparação dos valores de densidade óptica nas ROI antes e após aplicação ácida. Foram utilizados um aparelho radiográfico Gendex DC765 e o sistema Visualix Gx-S HDI para radiografia digital direta. Os resultados foram obtidos utilizando três tempos de exposição aos raios X (0.025, 0.050, 0.100s) com e sem a interposição de um simulador para tecidos moles. Variação no tempo de exposição aos raios X e uso de simulador tem influência sobre os valores de densidade óptica das imagens originais (p=0,00), o mesmo não ocorrendo para as imagens subtraídas. Os valores de densidade óptica também diferiram entre as ROI com e sem aplicação ácida (p=0,00) em ambas imagens originais e subtraídas. A variação na densidade óptica das ROI possibilitou avaliar a progressão da perda mineral em esmalte proximal, tanto nas imagens originais quanto nas subtraídas; a técnica de subtração digital da imagem radiográfica permitiu a visualização da progressão da perda mineral em esmalte proximal. / In this in vitro study, it was evaluated the mineral loss progression caused by the application of 18% hydrochloric acid in human premolars proximal enamel, using direct digital radiographic images and the digital subtraction radiography, comparing the optical density before an after acid application. It was used a Gendex DC765 X-ray generator and the Visualix Gx-S HDI digital X-ray. The results were obtained using three different X-rays exposures (0.175, 0.35, 0.7mAs) with and without the interference of a oral tissues simulator. The use of different X-ray exposure and interference of a oral tissues simulator had influenced on the optical density values for the original images (p=0,00), the same didn't occur for the digital subtracted images. The optical density values also differed among the ROI with and without acid application (p=0,00) in both original and subtracted images. The ROI optical density variation facilitated the evaluation of the proximal enamel mineral loss progression, in both original and subtracted images; the digital subtraction radiography allowed the visualization of the proximal enamel mineral loss progression.
|
12 |
Subtração digital radiográfica : identificação precoce de perdas minerais em esmalte /Dotto, Gustavo Nogara. January 2003 (has links)
Orientador: Luiz Cesar de Moraes / Banca: Luiz César de Moraes / Banca: Israel Chilvarquer / Banca: Julio Cezar de Melo Castilho / Resumo: Neste estudo in vitro, avaliou-se a progressão da perda mineral causada pela aplicação de ácido clorídrico a 18% em esmalte proximal de dentes pré-molares humanos, utilizando imagens radiográficas digitais diretas e também a técnica de subtração digital de imagens, por meio da comparação dos valores de densidade óptica nas ROI antes e após aplicação ácida. Foram utilizados um aparelho radiográfico Gendex DC765 e o sistema Visualix Gx-S HDI para radiografia digital direta. Os resultados foram obtidos utilizando três tempos de exposição aos raios X (0.025, 0.050, 0.100s) com e sem a interposição de um simulador para tecidos moles. Variação no tempo de exposição aos raios X e uso de simulador tem influência sobre os valores de densidade óptica das imagens originais (p=0,00), o mesmo não ocorrendo para as imagens subtraídas. Os valores de densidade óptica também diferiram entre as ROI com e sem aplicação ácida (p=0,00) em ambas imagens originais e subtraídas. A variação na densidade óptica das ROI possibilitou avaliar a progressão da perda mineral em esmalte proximal, tanto nas imagens originais quanto nas subtraídas; a técnica de subtração digital da imagem radiográfica permitiu a visualização da progressão da perda mineral em esmalte proximal. / Abstract: In this in vitro study, it was evaluated the mineral loss progression caused by the application of 18% hydrochloric acid in human premolars proximal enamel, using direct digital radiographic images and the digital subtraction radiography, comparing the optical density before an after acid application. It was used a Gendex DC765 X-ray generator and the Visualix Gx-S HDI digital X-ray. The results were obtained using three different X-rays exposures (0.175, 0.35, 0.7mAs) with and without the interference of a oral tissues simulator. The use of different X-ray exposure and interference of a oral tissues simulator had influenced on the optical density values for the original images (p=0,00), the same didn't occur for the digital subtracted images. The optical density values also differed among the ROI with and without acid application (p=0,00) in both original and subtracted images. The ROI optical density variation facilitated the evaluation of the proximal enamel mineral loss progression, in both original and subtracted images; the digital subtraction radiography allowed the visualization of the proximal enamel mineral loss progression. / Mestre
|
13 |
Capacidade diagnóstica da radiografia digital na avalição de reabsorções radiculares internas simuladas com desmineralização ácidaSilveira, Priscila Fernanda da January 2016 (has links)
Introdução: As reabsorções radiculares internas (RRI) são lesões de prognóstico difícil e o seu diagnóstico é baseado, principalmente, em exames de imagem. Tanto lesões pequenas quanto perfurações em lesões extensas são situações críticas e um desafio para o diagnóstico. As poucas pesquisas que investigaram a detecção de RRI e de perfurações causadas pelas mesmas, simularam as lesões com uso de brocas, criando cavidades com forma e limites definidos diferentes da realidade clínica. Assim, o objetivo deste estudo foi avaliar a capacidade diagnóstica das radiografias digitais, com diferentes filtros, em duas situações clínicas: na detecção de RRI pequenas; e na visualização das paredes dentinárias remanescentes e na detecção de perfurações em RRI simuladas, com desmineralização ácida. Materiais e métodos: Foram simuladas lesões de RRI com desmineralização ácida nos condutos radiculares de 42 dentes monorradiculares, seccionados no sentido coronal, reposicionados e colocados em alvéolos de uma mandíbula seca. Radiografias digitais com placas de fósforo (Vista Scan - Dürr Dental, Germany) com dissociação foram realizadas, em momentos diferentes para os objetivos, Obj.1: antes (GC) e após (GT) a simulação de RRI pequenas; Obj.2: após a simulação de lesões extensas com remanescente de parede dentinária (GC) e com perfuração da parede lateral da raiz (GT). Todas as imagens foram exportadas e 7 filtros de processamento foram aplicados para a análise mais a imagem original (sem filtro). Três examinadores utilizando uma escala Likert de 5 pontos avaliaram as imagens quanto: Obj.1, a presença/ausência de RRI; Obj.2, a presença/ausência de perfuração. O índice Kappa intra e inter-examinadores foi calculado para avaliar a reprodutibilidade. Testes de diagnóstico e AcROC foram calculados para cada grupo (GT e GC) e para cada filtro de imagem. A distância do escore determinado na escala até o valor do padrão-ouro foi utilizado para mensurar a certeza/incerteza no diagnóstico. Equações de Estimação Generalizadas (GEE) foram utilizadas para a análise estatística, com significância de 0,05%. Resultados: Valores moderados de Kappa-inter (0,403-0,620) e altos de intra-examinadores (0,757-0,915) foram observados. Para Obj.1: Maior percentual de acertos ocorreu no GC, significativamente (p<0,05). Imagens originais apresentaram maior sensibilidade e AcROC (0,595-0,750) e o filtro Endo apresentou maior especificidade (0,952), em relação às demais imagens, sem diferença estatística entre elas (p>0,05). Os filtros Inversion e Pseudo3D causaram maior incerteza no diagnóstico das RRI, estatisticamente significante para o GC com o filtro Pseudo3D (p<0,05). Para Obj.2: Imagens com o filtro Pseudo3D resultaram em mais escores de dúvida (73,5-78%), e maiores distâncias do padrão ouro, gerando maior incerteza no diagnóstico, significativamente (p<0,05), em relação aos demais filtros. Maior acROC (0,615) foi relacionada ao filtro Perio, sem diferença estatística (p>0,05). Maiores distâncias, refletindo maiores incertezas nos diagnósticos, foram observadas no GC para todos as imagens. O percentual de acerto foi menor conforme diminuiu a espessura da parede remanescente, com 31% de acerto para as espessuras de 0,2mm. Conclusões: Paras as lesões de RRI pequenas: os filtros Inversion e Pseudo3D são contraindicados, pois geram muit incertezas aumentando a probabilidade de erros de diagnóstico. Em casos de dúvida, a imagem sem filtro (Original) deve ser buscada, pois apresenta maior capacidade diagnóstica e permite maior certeza na avaliação. Para as lesões de RRI extensas, com suspeita de perfuração: o filtro Pseudo3D deve ser evitado pois gera maior incerteza no diagnóstico e filtro Perio deve ser incentivado, pois facilita a avaliação, aumentando as chances de diagnósticos corretos. Deve-se ter em mente que nos casos diagnosticados como perfuração, ainda pode existir uma camada de parede dentinária remanescente. / Introduction: Internal root resorption (RRI) are difficult to predict injuries and its diagnosis is mainly based on imaging studies. Both minor injuries as punctures in extensive lesions are critical situations and a challenge for diagnosis. The few studies that investigated the detection of RRI and punctures caused by them, simulated lesions with use of drills, creating cavities with different shape and defined limits of clinical reality. The objective of this study was to evaluate the diagnostic ability of digital radiographs with different filters in two clinical situations: small RRI detection; and in view of the remaining dentin walls and to detect perforations in RRI simulated with acid demineralization. Methods: RRI injuries were simulated with acid demineralization in root canals of 42 teeth monoradicular, sectioned coronally repositioned and placed in wells of a dry jaw. digital radiographs with phosphor plates (Vista Scan - Dürr Dental, Germany) and dissociation were taken at different times for the purposes, Aim 1: Before (CG=control group) and after (TG=test group) simulating small RRI; Aim 2: after simulation with extensive lesions reminiscent of dentinal wall (CG) and perforation on the lateral wall of the root (GT). All images were exported and 7 processing filters were applied to the analysis over the original image (no filter). Three examiners using a 5-point Likert scale images evaluated as Aim 1, the presence / absence of RRI; Aim 2, the presence / absence of perforation. The Kappa intra and inter-examiner was calculated to assess reproducibility. Diagnostic tests and AcROC were calculated for each group (CG and TG) and for each image filter. The distance determined score on the scale to the value of the gold standard was used to measure the certainty / uncertainty in diagnosis. Generalized Estimating Equations (GEE) were used for statistical analysis with significance level of 0.05%. Results: moderate values of Kappa-inter (0.403 to 0.620) and high intra-rater (0.757 to 0.915) were observed. For objective 1: A higher percentage of hits occurred in the GC, significantly (p <0.05). Original images showed higher sensitivity and AcROC (0.595 to 0.750) and Endo filter showed higher specificity (0.952), compared to other images, with no statistical difference between them (p> 0.05). The filter Inversion and Pseudo3D caused greater uncertainty in the diagnosis of RRI statistically significant GC with the filter Pseudo3D (p <0.05). For the purpose of 2: Images with the filter Pseudo3D resulted in more scores of doubt (from 73.5 to 78%), and greater distances from the gold standard, leading to greater uncertainty in the diagnosis, significantly (p <0.05) compared to other filters. Most acROC (0.615) was related to the filter Perio, with no statistical difference (p> 0.05). Greater distances, reflecting greater uncertainty in diagnosis were observed in the control group for all the images. The hit percentage was lower as decreased the thickness of the remaining wall, with 31% accuracy for thickness of 0.2 mm. Conclusions: Paras small lesions RRI: Inversion and the Pseudo3D filters are contraindicated because they generate too many uncertainties increasing the probability of misdiagnosis. In cases of doubt, the image without filter (Original) must be sought, because it has greater diagnostic capacity and allow greater certainty in the assessment. the extensive RRI injuries, suspected of drilling: the Pseudo3D filter should be avoided because it creates greater uncertainty in the diagnosis and filter Perio should be encouraged as it facilitates the evaluation, increasing the chances of correct diagnoses. It should be borne in mind that in cases diagnosed as drilling, there may still be a remaining dentin wall layer.
|
14 |
Comparação de diferentes resoluções espaciais do sistema digital Vistascan para o diagnóstico de lesão cariosa proximal / Comparison of different spacial resolutions of a digital system on the diagnosis of proximal cariesFerreira, Liana Matos, 1987- 24 August 2018 (has links)
Orientador: Francisco Haiter Neto / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-24T14:36:49Z (GMT). No. of bitstreams: 1
Ferreira_LianaMatos_M.pdf: 1448001 bytes, checksum: e9ef78a5716ed7904ac43ff5eb3b71f4 (MD5)
Previous issue date: 2014 / Resumo: O objetivo do presente estudo foi investigar o efeito da resolução espacial em placas de armazenamento de fósforo para a detecção de lesões de cárie proximais, utilizando 10, 20, 25 e 40 pl/mm. Cento e vinte e seis dentes (252 superfícies) humanos extraídos foram radiografados utilizando o sistema digital Vistascan e avaliados por três observadores treinados e com experiência em imagem digital. A escala de confiança que foi preenchida em relação à presença ou ausência de lesão cariosa consistia de: 1 ¿ definitivamente ausente; 2 ¿ provavelmente ausente; 3 ¿ incerteza; 4 ¿ provavelmente presente e 5 ¿ definitivamente presente. Se os itens 4 ou 5 fossem assinalados, os observadores deveriam identificar onde a lesão de cárie se encontrava: 1 ¿ lesão de cárie na metade externa do esmalte; 2 ¿ lesão de cárie na metade interna do esmalte e 3 ¿ dentina. Posteriormente, os dentes foram seccionados e examinados por microscopia de polarização para se obter o padrão ouro. Os resultados foram submetidos à análise de curva ROC (Receiver Operating Characteristic), para avaliar o desempenho dos avaliadores e do sistema na detecção das lesões cariosas proximais em esmalte e dentina. As áreas sob as curvas (Az) representam a eficiência da modalidade de diagnóstico. A análise de variância (ANOVA) não mostrou diferenças estatisticamente significativas nas áreas sob as curvas entre as quatro resoluções de imagem (p>0,05). Concluiu-se que para a detecção de lesões cariosas proximais, imagens com baixas e altas resoluções são igualmente precisas / Abstract: The aim of this study was to investigate the effect of spatial resolution in photostimulable storage phosphor (PSP) plate radiographs scanned in 10, 20, 25 and 40 lp/mm, on the detection of proximal caries lesions. Radiographs of 126 extracted human teeth (252 surfaces) were taken using the VistaScan PSP system and assessed by three calibrated examiners with experience in digital imaging. The scoring scale was: 1 = definitely no lesion; 2 = probably no lesion; 3 = unsure; 4 = probably lesion; and 5 = definitely lesion. If score 4 or 5 were selected, the observers should mark 1 = lesion <1/3 into enamel, 2 = lesion >1/3 into enamel, 3 = lesion in dentin. Subsequently, the teeth were sectioned and examined microscopically to obtain a gold standard. The results were analyzed by Receiver Operating Characteristic (ROC) analysis to evaluate the performance of examiners and resolution in the detection of proximal caries lesions in enamel and dentin. The areas under the curves, designated as Az, represents the efficiency of the diagnostic modality. Analysis of variance (ANOVA) compared the mean (among observers) ROC curve areas obtained by the various spatial resolutions. The gold standard frequency of caries lesions was 132 sound surfaces, 27 lesions <1/3 into enamel, 45 lesion >1/3 into enamel and 48 lesions into dentin. Analysis of variance showed no statistically significant differences in ROC curve area among the four image resolutions (p>0.05), neither when the threshold for disease was any lesion, nor when it was lesion into dentin. It was concluded that for the detection of proximal caries lesions, images with low and high resolution seem equally accurate / Mestrado / Radiologia Odontologica / Mestra em Radiologia Odontológica
|
15 |
Detecção de fraturas radiculares verticais em radiografias convencionais e digitais obtidas em três diferentes sistemas na presença e ausência de material intracanal / Detection of vertical root fractures in conventional and digital radiography obtained in three different systems in the presence and absence of intracanal materialsNascimento, Helena Aguiar Ribeiro do, 1986- 24 August 2018 (has links)
Orientador: Deborah Queiroz de Freitas França / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-24T14:50:35Z (GMT). No. of bitstreams: 1
Nascimento_HelenaAguiarRibeirodo_M.pdf: 1294865 bytes, checksum: aad6a2937765cf9381c0d31a4575d026 (MD5)
Previous issue date: 2014 / Resumo: O objetivo no presente estudo foi avaliar a detecção de fraturas radiculares verticais (FRVs) em radiografias convencionais (RCs) e obtidas em três sistemas digitais com diferentes condições intracanal. Foram utilizados 40 dentes humanos unirradiculares com as coroas seccionadas na junção cemento-esmalte. Em seguida, os dentes foram divididos em dois grupos com 20 dentes em cada: grupo controle sem fratura e grupo com FRV. As FRVs foram induzidas em uma máquina de ensaio universal. Após, todos os dentes foram posicionados individualmente no alvéolo de uma secção mandíbula humana seca. Foram obtidas imagens de todos os dentes de acordo com a condição intracanal: sem preenchimento, com guta-percha, com pino metálico e com pino de fibra de vidro. As imagens foram obtidas utilizando-se a técnica do paralelismo e três incidências (orto, mésio e distorradial), com filme convencional (Kodak), placas de armazenamento de fósforo (Digora Optime® e VistaScan®) e um sensor CMOS (SnapShot®). Todas as imagens foram avaliadas por cinco examinadores em uma escala de 5 pontos. Após trinta dias, 25% da amostra foi reavaliada. As reprodutibilidades intra e interexaminador foram avaliadas por meio do Teste Kappa ponderado. Foram calculados os valores de sensibilidade, especificidade, acurácia, valores preditivos positivo e negativo. A comparação das avaliações com o padrão-ouro foi obtida utilizando a área sob a curva ROC, comparadas por meio da análise de variância dois critérios com teste post-hoc de Tukey e nível de significância de 5%. As reprodutibilidades intra e interexaminador exibiram valores de moderado a substancial. Apenas a sensibilidade apresentou diferença significante entre as modalidades de imagem, com valores superiores para o SnapShot (53,3%) e VistaScan (46,0%), seguidos pela RC (41,0%) e Digora (37,5%). Ainda o sistema SnapShot (0,82) apresentou área sob a curva ROC maior que os demais (VistaScan: 0,70; Digora: 0,64; RC: 0,68) na presença do pino de fibra de vidro. Foi possível concluir que todas as modalidades de exame apresentaram um bom desempenho no diagnóstico de FRV na ausência de material intracanal e inferior na presença do pino metálico ou guta-percha. Na condição com pino de fibra de vidro, sistemas digitais com maiores resoluções devem ser preferidos / Abstract: This study aimed to evaluate the detection of vertical root fractures (VRFs) in conventional radiography (CR) and three digital systems in teeth with different intracanal condition. The sample consisted of forty single-rooted human teeth, in which the crowns were sliced at the cementoenamel junction. Then, the teeth were divided equally in two groups: control without fracture and root fracture. The VRFs were induced through a universal testing machine. After this process, all teeth were individually placed in a dry mandible. The images were obtained of all teeth according to the intracanal condition: no filling, gutta-percha, metal and fiberglass post. The images were obtained using the parallelism technique with three different horizontal angulations (ortho, mesial and distorradial) with conventional film (CF) (Kodak), two storage phosphor plates (Digora Optime® and VistaScan®) and one CMOS sensor system (SnapShot®). All images were evaluated by five examiners on a 5-point scale. After thirty days, 25% of the images were re-evaluated. The intra and interobserver reproducibility were calculated using the weighted-kappa test. Values of sensitivity, specificity, accuracy, positive and negative predictive values were calculated. The area under the ROC curve of all modalities in the presence of different intracanal materials was calculated and compared using the two-way analysis of variance (ANOVA) with post-hoc Tukey test and a significance level of 5%. The intra- and interobserver reproducibility values ranged from moderate to substantial. Only the sensitivity showed a significant difference between imaging modalities, with higher values for SnapShot (53,3%) and VistaScan (46,0%), followed by the CR (41,0%) and Digora (37,5%). Also SnapShot (0,82) had an area under the ROC curve greater than the others in the fiberglass post group (VistaScan: 0,70; Digora: 0,64; CR: 0,68). It was concluded that all imaging modalities had a good performance in the diagnosis of VRF in the absence of intracanal materials and lower in the presence of the metal post or gutta-percha. In the fiberglass post group, digital systems with higher resolution should be used / Mestrado / Radiologia Odontologica / Mestra em Radiologia Odontológica
|
16 |
An in vitro comparison of working length accuracy between a digital system and conventional film when vertical angulation of the object is variableChristensen, Shane R. January 2009 (has links)
Thesis (M.S.D.)--Indiana University School of Dentistry, 2009. / Title from PDF t. p. (viewed Aug. 21, 2009) Advisor(s): Mychel Vail, Acting Chair of the Research Committee, Joseph Legan, Kenneth Spolnik, Susan L. Zunt, Edwin Parks. Curriculum vitae. Includes abstract. Includes bibliographical references (leaves 109-120).
|
17 |
Cimento endodôntico antimicrobiano com a incorporação de vanadato de prata - análise das propriedades físicas e microbiológicas / Antimicrobial endodontic sealer with the incorporation of silver vanadate - analysis of the physical and microbiological propertiesTeixeira, Ana Beatriz Vilela 25 January 2017 (has links)
O desenvolvimento de cimentos endodônticos com maior capacidade antimicrobiana, leva a associação de cimentos endodônticos com agentes antimicrobianos. O vanadato de prata nanoestruturado decorado com nanopartículas de prata (AgVO3) é um nanomaterial com capacidade antimicrobiana com aplicação na odontologia. O objetivo desse trabalho foi avaliar quatro cimentos endodônticos (AH Plus, Sealapex, Sealer 26 e Endofill) incorporados com AgVO3, em diferentes concentrações (0%, 2,5%, 5% e 10%), através de testes in vitro de concentração inibitória mínima (CIM) e capacidade antimicrobiana (difusão em ágar) (n=6) frente aos micro-organismos: Enterococcus faecalis, Pseudomonas aeruginosa, Escherichia coli. Testes das propriedades físicas de escoamento (n=6), radiopacidade (n=5), teste de alteração de cor da estrutura dental (n=3) e padrão de distribuição superficial do AgVO3 aos cimentos endodônticos (n=5) foram realizados. Para análise estatística da capacidade antimicrobiana e escoamento foram realizados teste paramétrico 2-way ANOVA e teste de Tukey honestly significant difference (HSD), os dados da radiopacidade foram analisados pelo teste Kruskal-Wallis e teste de permutação com nível de significância de 5%, e para a alteração de cor realizou-se análise estatística descritiva. A CIM do AgVO3 para E. faecalis foi de 500 µg/mL e para P. aeruginosa e E. coli de 31,25 µg/mL. A incorporação de 10% de AgVO3 promoveu maior atividade antimicrobiana a todos os cimentos frente a E. coli, ao Sealer 26 e Sealapex frente a E. faecalis e ao AH Plus e Endofill frente a P. aeruginosa (p<0,05). A incorporação de AgVO3 não influenciou na atividade antimicrobiana inerente do AH Plus frente a E. faecalis (p>0,05) e não promoveu tal propriedade ao Sealer 26 e Sealapex frente a P. aeruginosa (p>0,05). O escoamento do AH Plus e Endofill reduziu com o aumento da concentração de AgVO3 (p<0,05). Não houve influência no escoamento do Sealer 26 e Sealapex (p>0,05). Todos os grupos apresentaram valores de escoamento dentro do recomendado pela American National Standard/American Dental Association (ANSI/ADA), exceto o AH Plus 10%. O AgVO3 não influenciou na radiopacidade do Endofill (p=0,399) e Sealapex (p=0,316), e a concentração de 2,5% do Sealer 26 e AH Plus apresentou maior radiopacidade em relação ao controle (p=0,022 e p=0,006, respectivamente), que não diferiu dos demais grupos (p>0,05). Todos cimentos incorporados com AgVO3 apresentaram maiores alterações de cor após 180 dias, a menor alteração foi do Endofill 10% e a maior do Sealer 26 10%. O AgVO3 apresentou um padrão de distribuição superficial circular na composição dos cimentos endodônticos. Concluiu-se que a incorporação do AgVO3 tem potencial para aumentar a atividade antimicrobiana dos cimentos endodônticos avaliados, não influenciou no escoamento do Sealer 26 e Sealapex, e na radiopacidade dos cimentos avaliados. Os grupos incorporados com AgVO3 apresentaram maior alteração de cor com 180 dias, exceto o Endofill 10%. / The development of endodontic sealers with higher antimicrobial capacity, leads to the association of endodontic sealers with antimicrobial agents. The nanostructured silver vanadate decorated with silver nanoparticles (AgVO3) is an antimicrobial nanomaterial with application in dentistry. The aim of this study was to evaluate four endodontic sealers (AH Plus, Sealapex, Sealer 26 and Endofill) incorporated with AgVO3, in different concentrations (0%, 2.5%, 5% and 10%), through in vitro tests of minimum inhibitory concentration (MIC) and antimicrobial capacity (agar diffusion method) (n=6) against microorganisms: Enterococcus faecalis, Pseudomonas aeruginosa, Escherichia coli. Tests on physical properties of flow (n = 6), radiopacity (n = 5), tooth discoloration (n = 3) and superficial distribution pattern of the AgVO3 to endodontic sealers (n = 5) were performed. For statistical analysis of antimicrobial capacity and flow, were performed the 2-way ANOVA parametric test and the Tukey honestly significant difference (HSD) test, the radiopacity data were analyzed by the Kruskal-Wallis test and permutation test with significance level of 5%, and descriptive statistical analysis was performed for tooth discoloration. The MIC of AgVO3 for E. faecalis was 500 µg/mL and for P. aeruginosa and E. coli 31,25 µg/mL. The incorporation of 10% of AgVO3 increased antimicrobial activity to all sealers against E. coli, to Sealer 26 and Sealapex against E. faecalis and to AH Plus and Endofill against P. aeruginosa (p <0.05). The incorporation of AgVO3 did not influence on antimicrobial activity inherent of the AH Plus against E. faecalis (p> 0.05) and did not promote this property to Sealer 26 and Sealapex against P. aeruginosa (p> 0.05). The flow of AH Plus and Endofill decreased with increasing AgVO3 concentration (p <0.05). There was no influence on the flow of Sealer 26 and Sealapex (p> 0.05). The evaluated groups presented flow values within the recommended by the American National Standard/American Dental Association (ASNI/ADA), except the AH Plus 10%. The AgVO3 did not influence the radiopacity of Endofill (p = 0.399) and Sealapex (p = 0.316), the concentration of 2.5% of Sealer 26 and AH Plus presented higher radiopacity than the control (p = 0.022 and p = 0.006, respectively), which did not differ from the other groups (p> 0.05). All sealers incorporated with AgVO3 presented color alterations after 180 days, the lowest change was Endofill 10% and the highest was Sealer 26 10%. The AgVO3 presented a pattern of circular superficial distribution in the composition of the endodontic sealers. It is concluded that the incorporation of AgVO3 has the potential to increase the antimicrobial activity of the endodontic sealers evaluated, did not influence the flow of the Sealer 26 and Sealapex, and the radiopacity of sealers evaluated. The groups incorporated with AgVO3 presented color alterations with 180 days, except Endofill 10%.
|
18 |
Cimento endodôntico antimicrobiano com a incorporação de vanadato de prata - análise das propriedades físicas e microbiológicas / Antimicrobial endodontic sealer with the incorporation of silver vanadate - analysis of the physical and microbiological propertiesAna Beatriz Vilela Teixeira 25 January 2017 (has links)
O desenvolvimento de cimentos endodônticos com maior capacidade antimicrobiana, leva a associação de cimentos endodônticos com agentes antimicrobianos. O vanadato de prata nanoestruturado decorado com nanopartículas de prata (AgVO3) é um nanomaterial com capacidade antimicrobiana com aplicação na odontologia. O objetivo desse trabalho foi avaliar quatro cimentos endodônticos (AH Plus, Sealapex, Sealer 26 e Endofill) incorporados com AgVO3, em diferentes concentrações (0%, 2,5%, 5% e 10%), através de testes in vitro de concentração inibitória mínima (CIM) e capacidade antimicrobiana (difusão em ágar) (n=6) frente aos micro-organismos: Enterococcus faecalis, Pseudomonas aeruginosa, Escherichia coli. Testes das propriedades físicas de escoamento (n=6), radiopacidade (n=5), teste de alteração de cor da estrutura dental (n=3) e padrão de distribuição superficial do AgVO3 aos cimentos endodônticos (n=5) foram realizados. Para análise estatística da capacidade antimicrobiana e escoamento foram realizados teste paramétrico 2-way ANOVA e teste de Tukey honestly significant difference (HSD), os dados da radiopacidade foram analisados pelo teste Kruskal-Wallis e teste de permutação com nível de significância de 5%, e para a alteração de cor realizou-se análise estatística descritiva. A CIM do AgVO3 para E. faecalis foi de 500 µg/mL e para P. aeruginosa e E. coli de 31,25 µg/mL. A incorporação de 10% de AgVO3 promoveu maior atividade antimicrobiana a todos os cimentos frente a E. coli, ao Sealer 26 e Sealapex frente a E. faecalis e ao AH Plus e Endofill frente a P. aeruginosa (p<0,05). A incorporação de AgVO3 não influenciou na atividade antimicrobiana inerente do AH Plus frente a E. faecalis (p>0,05) e não promoveu tal propriedade ao Sealer 26 e Sealapex frente a P. aeruginosa (p>0,05). O escoamento do AH Plus e Endofill reduziu com o aumento da concentração de AgVO3 (p<0,05). Não houve influência no escoamento do Sealer 26 e Sealapex (p>0,05). Todos os grupos apresentaram valores de escoamento dentro do recomendado pela American National Standard/American Dental Association (ANSI/ADA), exceto o AH Plus 10%. O AgVO3 não influenciou na radiopacidade do Endofill (p=0,399) e Sealapex (p=0,316), e a concentração de 2,5% do Sealer 26 e AH Plus apresentou maior radiopacidade em relação ao controle (p=0,022 e p=0,006, respectivamente), que não diferiu dos demais grupos (p>0,05). Todos cimentos incorporados com AgVO3 apresentaram maiores alterações de cor após 180 dias, a menor alteração foi do Endofill 10% e a maior do Sealer 26 10%. O AgVO3 apresentou um padrão de distribuição superficial circular na composição dos cimentos endodônticos. Concluiu-se que a incorporação do AgVO3 tem potencial para aumentar a atividade antimicrobiana dos cimentos endodônticos avaliados, não influenciou no escoamento do Sealer 26 e Sealapex, e na radiopacidade dos cimentos avaliados. Os grupos incorporados com AgVO3 apresentaram maior alteração de cor com 180 dias, exceto o Endofill 10%. / The development of endodontic sealers with higher antimicrobial capacity, leads to the association of endodontic sealers with antimicrobial agents. The nanostructured silver vanadate decorated with silver nanoparticles (AgVO3) is an antimicrobial nanomaterial with application in dentistry. The aim of this study was to evaluate four endodontic sealers (AH Plus, Sealapex, Sealer 26 and Endofill) incorporated with AgVO3, in different concentrations (0%, 2.5%, 5% and 10%), through in vitro tests of minimum inhibitory concentration (MIC) and antimicrobial capacity (agar diffusion method) (n=6) against microorganisms: Enterococcus faecalis, Pseudomonas aeruginosa, Escherichia coli. Tests on physical properties of flow (n = 6), radiopacity (n = 5), tooth discoloration (n = 3) and superficial distribution pattern of the AgVO3 to endodontic sealers (n = 5) were performed. For statistical analysis of antimicrobial capacity and flow, were performed the 2-way ANOVA parametric test and the Tukey honestly significant difference (HSD) test, the radiopacity data were analyzed by the Kruskal-Wallis test and permutation test with significance level of 5%, and descriptive statistical analysis was performed for tooth discoloration. The MIC of AgVO3 for E. faecalis was 500 µg/mL and for P. aeruginosa and E. coli 31,25 µg/mL. The incorporation of 10% of AgVO3 increased antimicrobial activity to all sealers against E. coli, to Sealer 26 and Sealapex against E. faecalis and to AH Plus and Endofill against P. aeruginosa (p <0.05). The incorporation of AgVO3 did not influence on antimicrobial activity inherent of the AH Plus against E. faecalis (p> 0.05) and did not promote this property to Sealer 26 and Sealapex against P. aeruginosa (p> 0.05). The flow of AH Plus and Endofill decreased with increasing AgVO3 concentration (p <0.05). There was no influence on the flow of Sealer 26 and Sealapex (p> 0.05). The evaluated groups presented flow values within the recommended by the American National Standard/American Dental Association (ASNI/ADA), except the AH Plus 10%. The AgVO3 did not influence the radiopacity of Endofill (p = 0.399) and Sealapex (p = 0.316), the concentration of 2.5% of Sealer 26 and AH Plus presented higher radiopacity than the control (p = 0.022 and p = 0.006, respectively), which did not differ from the other groups (p> 0.05). All sealers incorporated with AgVO3 presented color alterations after 180 days, the lowest change was Endofill 10% and the highest was Sealer 26 10%. The AgVO3 presented a pattern of circular superficial distribution in the composition of the endodontic sealers. It is concluded that the incorporation of AgVO3 has the potential to increase the antimicrobial activity of the endodontic sealers evaluated, did not influence the flow of the Sealer 26 and Sealapex, and the radiopacity of sealers evaluated. The groups incorporated with AgVO3 presented color alterations with 180 days, except Endofill 10%.
|
19 |
Análise morfométrica, radiográfica e molecular do processo de reparo alveolar após a terapia fotodinâmica antimicrobiana em ratos Wistar / Morphometric, molecular and radiographic analysis of the alveolar repair process after antimicrobial photodynamic therapy in Wistar ratsPoleti, Marcelo Lupion 24 April 2009 (has links)
Introdução: Com o aumento da resistência bacteriana à antibioticoterapia tornou-se necessário o desenvolvimento de técnicas antimicrobianas alternativas. Assim, na busca de novas metodologias contra microrganismos, estudos usando a Terapia Fotodinâmica (TFD) antimicrobiana tem sido realizados. Objetivo: Realizar análise morfométrica, radiográfica e molecular do processo de reparo alveolar após a TFD antimicrobiana em ratos Wistar. Material e Métodos: Foram utilizados 85 ratos, divididos nos seguintes grupos: GRUPO C: Animais com alvéolo não tratado (grupo controle); GRUPO S+L: Animais com alvéolo preenchido com soro fisiológico e tratado apenas com aplicação do Laser de baixa intensidade (660 nm), com fluência de 50 J/cm2; GRUPO ATO: Animais com alvéolo tratado apenas com aplicação tópica de azul de toluidina - O (ATO) na concentração de 100 µg/mL e GRUPO ATO+L: Animais com alvéolo tratado com aplicação tópica de azul de toluidina O (ATO) na concentração de 100 µg/mL + aplicação de Laser de baixa intensidade (660 nm), com fluência de 50 J/cm2. Os animais foram sacrificados aos 6, 15 e 28 dias pós-operatório. O mapeamento térmico foi realizado em um animal para confirmar a ausência de efeito térmico do Laser sobre o local irradiado. Foram realizadas as análises microscópicas: qualitativa e quantitativa de tecido conjuntivo, tecido ósseo, coágulo sanguíneo, vaso sanguíneo, infiltrado inflamatório e espaço vazio; radiográfica: por meio do valor de pixel e dimensão fractal e molecular: quantitativa da expressão de genes envolvidos no processo de reparo: colágeno tipo I (COL-I), fator de crescimento do endotélio vascular (VEGF), runt-related transcription factor 2 (RUNX2), osteocalcina (OCN) e fosfatase alcalina (ALP), por meio da PCR Real Time. Resultados e Conclusão: Os resultados demonstraram que a TFD antimicrobiano não atuou negativamente na evolução do processo de reparo alveolar; a análise radiográfica por meio dos valores de pixel pode ser usada como indicador para avaliar a neoformação óssea no processo de reparo alveolar em ratos; a expressão de VEGF pode ser usada como marcador molecular para a angiogênese no processo de reparo alveolar em ratos e a expressão de fosfatase alcalina pode ser usada como marcador molecular nos estágios iniciais do metabolismo ósseo no processo de reparo alveolar em ratos. / Introduction: Antibiotics resistance made the development of antimicrobial alternative techniques necessary. Consequently, others alternatives such as antimicrobial photodynamic therapy (PDT) have been studied. Objective: The objectives were to perform morphometric, radiographic and molecular analyses of alveolar repair process in rats after antimicrobial photodynamic therapy. Methods: Eighty-five rats were used in this study, divided according to the following groups: C: untreated socket; S+L: socket treatment with physiologic saline solution and low intensity laser therapy (660nm - 50J/cm2); ATO: socket treatment with topic application of toluidine blue-O (100 µg/mL) and ATO+L: socket treatment with topic application of toluidine blue-O (100µg/ml) and low intensity laser therapy (660nm - 50J/cm2). The animals were sacrificed at a postoperative period of 6, 15 and 28 days. Thermal variation was carried out in an animal to confirm the absence of Laser thermal effect on irradiation area. Quantitative and qualitative microscopic analyses were performed to evaluate the connective tissue, bone tissue, blood clot, blood vessel, inflammatory infiltrate and empty space. Fractal and Pixel radiographic analysis were performed. A quantitative analysis was performed using a RealTimePCR to evaluate the genes expression involved Collagen Type I (COL-I), vascular endothelial growth factor (VEGF), runt-related transcription factor 2 (RUNX2), osteocalcin (OCN), alkaline phosphatase (ALP), in the alveolar repair process. Results and Conclusions: Based in the results, it can be concluded that antimicrobial photodynamic therapy did not act negatively in the socket bone repair evaluation. Pixel values analysis could be used as indicators to evaluate the dry socket bone neoformation. The VEGF molecular marker could be used as angiogenesis indicator to evaluate the dry socket bone neoformation as well as alkaline phosphatase as a molecular marker in the early stage of bone neoformation.
|
20 |
Análise densitométrica digital do processo de reparo em dentes de rato reimplantadosGiovanini, Ellen Greves [UNESP] 30 November 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:25:20Z (GMT). No. of bitstreams: 0
Previous issue date: 2006-11-30Bitstream added on 2014-06-13T20:13:38Z : No. of bitstreams: 1
giovanini_eg_me_araca.pdf: 1544057 bytes, checksum: 1b518f21ba8bc63249a3f29eb78ba402 (MD5) / A avulsão dentária é caracterizada pelo completo deslocamento do dente do seu alvéolo e a melhor forma de tratar um dente avulsionado é o seu reimplante. Mesmo diante das melhores circunstâncias os reimplantes tardios falham devido à reabsorção radicular que é detectada apenas durante a avaliação radiográfica. A imagem digital surgiu como um recurso diagnóstico rápido e de fácil utilização sendo considerada precisa. Para diminuir a variabilidade de interpretação é sugerida a análise radiográfica quantitativa por meio da densidade radiográfica. O propósito deste trabalho foi analisar comparativamente o processo de reparo do reimplante dental em ratos utilizando a análise densitométrica no sistema digital Digora. Foram utilizados 30 ratos machos, divididos em 3 grupos de 10 animais, que tiveram seu incisivo superior direito extraído e tratado da seguinte forma: grupo I - reimplante imediato, grupo II - reimplante tardio sem tratamento e o grupo III - reimplante tardio com tratamento da superfície radicular utilizando raspagem do ligamento e fluoreto de sódio. Os animais foram sacrificados após 60 dias do ato operatório, suas maxilas foram separadas e as imagens radiográficas obtidas de forma que sobre cada placa óptica ficassem as duas hemimaxilas (tratada e controle), o penetrômetro de alumínio e a identificação. Foram realizadas medidas de densidade em áreas padronizadas no sistema Digora. Os valores densitométricos encontrados foram submetidos à análise de variância e teste de Tuckey, e análise não paramétrica do número de áreas de reabsorção. Podemos concluir que a análise densitométrica constitui um importante exame complementar para o acompanhamento dos reimplantes uma vez que permitiu a detecção de reabsorção radicular em todos os grupos, cuja ordem decrescente de envolvimento foi o grupo do reimplante tardio sem tratamento... / The dental replanted has been considered the best treatment of the tooth avulsion, which is characterized by complete alveolar dislodgment of the tooth. Despite of the adequate clinical situations, the delayed replantation fails due to the root resorption that is detected during the radiographic evaluation. The use of the digital image represent a fast and easy diagnostic resource, furthest more precise. The quantitative radiographic analysis has been suggested to reduce the interpretation variability through the radiographic density. The purpose of this work was to analyze the process of repair of the dental replanted using the digital densitometry in the Digora system. The 30 male rats were divided in 3 groups of 10 animals, and their right superior incisor were extracted and treated agreement with their group: group I - immediate replanted, group II - delayed replanted without treatment and the group III - delayed replanted with treatment of the root surface using fluoride of sodium. The animals were sacrificed after 60 days operative act, your jawbones were separate and the radiographic images obtained so that on each optical plate were the two jawbones (treated and control), the aluminum step wedge and the identification. The radiographic density of radicular standardized area in Digora system was measured. The densitometric values were submitted to the variance analysis and test of Tuckey and analysis non parametric of the number of areas root resoption. We can end that digital densitometry analysis it an important complementary for replanted evaluation once it allowed the detection of root reabsorption in all of the groups, whose decreasing order of involvement was the group of the delayed replanted without treatment, following for the delayed replanted with treatment and last the immediate replanted.
|
Page generated in 0.0731 seconds