• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 18
  • 1
  • Tagged with
  • 19
  • 19
  • 16
  • 16
  • 8
  • 8
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Sistema dosimétrico portátil sem fio para uso em radiologia

OLIVEIRA, Charles Nilton do Prado. 21 August 2015 (has links)
Submitted by Isaac Francisco de Souza Dias (isaac.souzadias@ufpe.br) on 2016-06-13T19:13:46Z No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Dissertacao_Charles.pdf: 4536947 bytes, checksum: 646198e97695c41d56a17eb67e2ca63b (MD5) / Made available in DSpace on 2016-06-13T19:13:46Z (GMT). No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Dissertacao_Charles.pdf: 4536947 bytes, checksum: 646198e97695c41d56a17eb67e2ca63b (MD5) Previous issue date: 2015-08-21 / Para medir a dose em procedimentos que utilizam raios X foi desenvolvido um sistema dosimétrico. O equipamento desenvolvido consiste de um dosímetro portátil de leitura direta com base em detectores semicondutores e um sistema computacional de processamento de dados instalado em um computador. A comunicação entre o dosímetro portátil e o sistema computacional pode ser realizada via rede sem fio ou conexão USB. Diversos dosímetros podem ser conectados a um mesmo sistema computacional. Os dados que trafegam pela rede são transmitidos em tempo real para todos os usuários através de um protocolo de comunicação desenvolvido especialmente para este projeto. O sistema tem potencial de aplicação tanto na dosimetria de paciente como na monitoração ocupacional. O sistema dosimétrico foi testado nas qualidades de radiodiagnóstico definidas pela IEC 61267 denominadas de RQR3, RQR5, RQR8, RQRI0. Na monitoração ocupacional foram utilizadas as qualidades de radioproteção definidas pela ISO 4037 conhecidas como 40, N60, N80, NI00 e N120. Além disso, o dosímetro foi também avaliado com energias dos raios gama do Cs-137 e Co-60. Com base nos resultados, pode-se observar que a resposta do dosímetro possui coeficiente de variação menor 1 % e desvio padrão inferior a 10 % nos testes de reprodutibilidade. O sistema apresenta uma resposta linear quando exposto ao kerma no ar nas qualidades de radiação estudadas. / A dosimetric system has been developed for dose measurement in procedures which makes use of X-rays. The developed instrument consists of a semiconductor-detector based portable wireless dosimeter and a computational data processing system installed in a computer. Communication between the portable dosimeter and the system installed on the computer can be performed via wireless network or USB. Several portable dosimeters can be connected to one computational system. The data that travel over the network are transmitted in real time to all users through a communication protocol specifically designed for this application. The system has potential application in both for patient dosimetry and occupational monitoring. The dosimetric system has been tested at the IEC 61267 radiation qualities RQR3, RQR5, RQR8 and RQR10, for radiology, and, ISO 4037 N40, N60, N80, N100 and N120, for occupational monitoring. Moreover, the dosimeter has also been evaluated in gamma ray energies of Cs-137 and Co-60. Based on the results, one can observe that the dosimeter response has a coefficient of variation below 1 %, and a standard deviation lower than 10 % for reproducibility tests. The system displays a linear response when exposed to Air Kerma for the studied radiation qualities.
2

Embolização das arterias uterinas como tratamento de miomas sintomaticos

Martins, Mauricio de Sena 31 July 2018 (has links)
Orientadores: Gustavo Antonio de Souza, Cecilia Maria Roteli Martins / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-07-31T14:57:07Z (GMT). No. of bitstreams: 1 Martins_MauriciodeSena_D.pdf: 1215934 bytes, checksum: 1b03cb75f02b54915711c5e4394ba117 (MD5) Previous issue date: 2001 / Doutorado
3

REDUÇÃO DA DOSE DE RADIAÇÃO EM PACIENTES E EQUIPES MÉDICAS PELO USO DE FILTROS ADICIONAIS DE COBRE E ALUMÍNIO NAS SAÍDAS DE TUBOS DE RAIOS X EM EQUIPAMENTOS DE HEMODINÂMICA / REDUCTION OF THE DOSE OF RADIATION IN PATIENTS AND MEDICAL TEAMS BY THE USE OF ADDITIONAL FILTERS OF COPPER AND ALUMINUM IN THE EXITS OF TUBES OF X-RAY IN EQUIPMENTS OF HEMODYNAMIC

Weis, Guilherme Lopes 18 March 2011 (has links)
The use of ionizing radiations, x-rays, are the services of hemodynamic which aim to perform the diagnosis and the therapy of many kinds of heart illnesses. In the Services of Hemodynamic the most preoccupying aspects concerning the levels of radiation exposure not only of the patients but of medical team as well, is the time of which exposure occurs. As means of reducing the time of total exposure which is extremely dependent on the behavior of the professionals during the procedure, it can be cited the reduction of the time of the total exposure the position of the team into the room, the use of equipments of individual protection, and the distance of the tube intensifier of the images concerning the patient, among other factors. The application of these means of reduction of the exposure is variable according to the medical teams. So, the proposal of this work is to reduce the levels of exposure of an independent form of that form the medical team are using these equipments. It is proposed the use of additional filters in the exit of the x-ray in the three equipments of different generations, HEMOCOR SM - Interventionist Cardiology, Heart Institute - ICOR and the University Hospital of Santa Maria-HUSM, with the main objective of reducing the radiation of low energy that increase the exposure of patients and medical team. The principal difficulty faced with the use of the filters is the reduction of the quality of the image, that is, the loss of information aiming to correct the diagnosis. In order to quantify the quality of the image, a simulator was mounted with plates of aluminum and with other devices overlapping them to make it possible to measure and to compare the obtained images. In order to avoid doubting the evaluation of the images produced among the observers (inter-observers) and even among the own observatory (intra-observer), methods of analyze of images (threshold, histogram, surface 3D) was used, where it is possible to measure the relation sign noise, the special resolution, the contrast and the definition of the area of the sign. It was used ionization chambers which were placed in the position of the entrance of the skin of the patient, in the entrance in the tube intensifier and in the position of the hemodynamic doctor in order to quantify the reduction of doses when the filters were added. After they chose of the ideal filter for every type of the equipment, it was measured the effective dose of hemodynamic , using personal dosimeters during the clinical procedures. These effective doses were compared with those obtained without the use of filters for the same clinical procedures. So, it was possible to quantify the real reduction of the exposure of the medical team. In the case of HUSM, in the fluoroscopy-type, the adding filtration of 0,29 mm of Cu more 1 mm of Al showed the better results, allowing a reduction in the Rate of Kerma in the Air in the Entrance of the Skin of the Patient of 55,89% and a reduction of Rate of Kerma in the Air at 70 cm of distance in the direction of the hemodynamic doctor of 38,8%. Already, in the pencil-type, the additional filtration of 0,29 mm of Cu plus 2 mm of Al showed better results, allowing a reduction in the Rate of Kerma in the Air in the Entrance of the Skin of the Patient at 80,3% and a reduction of Rate of Kerma in the Air at 70 cm of distance in the direction of the hemodynamic doctor of 68,55%. For the HEMOCOR, in the fluoroscopy-type the additional filtration of 0,29 mm de Cu plus 2 mm of Al presented better results, allowing a reduction in the Rate of Kerma in the Air in the Entrance of the Skin of the Patient of 48,81% and a reduction in the Rate of Kerma in the Air at 70 cm of distance in the direction of the hemodynamic doctor of 23,91%. Already in the pencil-type, the additional filtration of 0,29 mm de Cu more 2 mm of Al presented the better results, allowing a reduction in the Rate of Kerm in the Air in the Entrance of the Skin of the Patient of 72,53% and a reduction in the Rate of Kerma in the Air at 70 cm of distance in the direction of the hemodynamic doctor of 52,30%. For the ICOR, in the fluoroscopy-type, it was not possible to collect information, because the equipment does not produce images DICOM, nor it keeps the last image in the monitor. Already, in the pencil-type, the additional filtration of 0,58 mm of Cu plus 1 mm of Al presented better results, allowing a reduction in the Rate of Kerma in the Air in the Entrance of the Skin of the Patient of 82,27% and a reduction in the Rate of the Kerma in the air at 70 cm of distance in the direction of the hemodynamic doctor of 75%. In the analysis of the personal dosimeter held in the HUSM, it was possible to calculate a global reduction of dose of 55%. So, it can be said that, with the use of additional filters, the dose of radiation in the patient and medical team can be reduced without damage of the diagnosis. This reduction is still more significant for the professionals that work in more than one service of Hemodynamic. / No âmbito do uso das radiações ionizantes, raios X, estão os Serviços de Hemodinâmica que tem como objetivo realizar o diagnóstico e a terapia de diversos tipos de doenças cardiovasculares. Nos Serviços de Hemodinâmica, os aspectos mais preocupantes em relação aos níveis de exposição às radiações, tanto do paciente quanto da equipe médica, é o longo tempo de exposição. Como meios de reduzir os níveis de radiação, que são extremamente dependentes do comportamento dos profissionais durante o procedimento, pode-se citar a redução do tempo de exposição total, a melhor posição da equipe dentro da sala, o uso dos equipamentos de proteção individual, a menor distância do tubo intensificador de imagens em relação ao paciente, dentre outros fatores. A aplicação destes meios de redução das exposições é variável de acordo com as equipes médicas. Assim, a proposta deste trabalho é reduzir os níveis de exposição de uma forma independente da equipe médica que esteja utilizando estes equipamentos. Propõese o uso de filtros adicionais na saída do tubo de raios X em três equipamentos de diferentes gerações, HEMOCOR SM Cardiologia Intervencionista, Instituto do Coração de Santa Maria ICOR e Hospital Universitário de Santa Maria - HUSM, com o objetivo principal de reduzir as radiações de baixa energia que aumentam a exposição do paciente e da equipe médica. A principal dificuldade a ser enfrentada com o uso dos filtros é a redução da qualidade da imagem, ou seja, a perda de informação visando o correto diagnóstico. Para quantificar-se a qualidade da imagem montou-se um simulador com placas de alumínio e com outros dispositivos nelas sobrepostos que possibilitam mensurar e comparar as imagens adquiridas. Para evitar-se dúvidas da avaliação das imagens geradas entre observadores (interobservadores) e mesmo entre o próprio observador (intra-observador), utilizouse métodos de análise de imagens (threshold, histograma, superfície 3D), onde pode-se medir a relação sinal ruído, a resolução espacial, o contraste e a definição da área do sinal. Utilizaram-se câmaras de ionização dispostas na posição da entrada da pele do paciente, na entrada do tubo intensificador de imagens e na posição do médico hemodinamicista para quantificar-se a redução das doses ao adicionar-se os filtros. Após a escolha do filtro ideal para cada tipo de equipamento mediu-se a dose efetiva do médico hemodinamicista, utilizando-se dosímetros pessoais durante os procedimentos clínicos. Estas doses efetivas foram comparadas com as obtidas sem o uso de filtros para os mesmos procedimentos clínicos. Desta forma pode-se quantificar a redução real da exposição da equipe médica. No caso do HUSM, no modo fluoroscopia a filtração adicional de 0,29 mm de Cu mais 1 mm de Al apresentou os melhores resultados, permitindo uma redução na Taxa de Kerma no Ar na Entrada da Pele do Paciente de 55,89% e uma redução da Taxa de Kerma no Ar a 70 cm de distância na direção do médico hemodinamicista de 38,8%. Já, no modo grafia, a filtração adicional de 0,29 mm de Cu mais 2 mm de Al apresentou os melhores resultados, permitindo uma redução na Taxa de Kerma no Ar na Entrada da Pele do Paciente de 80,3% e uma redução da Taxa de Kerma no Ar a 70 cm de distância na direção do médico hemodinamicista de 68,55%. Para o HEMOCOR, no modo fluoroscopia a filtração adicional de 0,29 mm de Cu mais 2 mm de Al apresentou os melhores resultados, permitindo uma redução na Taxa de Kerma no Ar na Entrada da Pele do Paciente de 48,81% e uma redução da Taxa de Kerma no Ar a 70 cm de distância na direção do médico hemodinamicista de 23,91%. Já, no modo grafia, a filtração adicional de 0,29 mm de Cu mais 2 mm de Al apresentou os melhores resultados, permitindo uma redução na Taxa de Kerma no Ar na Entrada da Pele do Paciente de 72,53% e uma redução da Taxa de Kerma no Ar a 70 cm de distância na direção do médico hemodinamicista de 52,30%. Para o ICOR, no modo fluoroscopia não foi possível coletar informações, pois o equipamento não gera imagens DICOM, nem mantém a última imagem no monitor. Já, no modo grafia, a filtração adicional de 0,58 mm de Cu mais 1 mm de Al apresentou os melhores resultados, permitindo uma redução na Taxa de Kerma no Ar na Entrada da Pele do Paciente de 87,27% e uma redução da Taxa de Kerma no Ar a 70 cm de distância na direção do médico hemodinamicista de 75%. Na análise da dosimetria pessoal realizada no HUSM, foi possível calcular uma redução global de dose de 55%. Desta forma pode-se afirmar que, com o uso dos filtros adicionais, a dose de radiação no paciente e equipes médicas pode ser reduzida sem prejuízo do diagnóstico. Esta redução é ainda mais significativa para os profissionais que trabalham em mais de um Serviço de Hemodinâmica.
4

Resultados da vertebroplastia percutânea na doença vertebral cervical / Results of percutaneous vertebroplasty in the cervical spine

Mont'Alverne, Francisco José Arruda 17 November 2008 (has links)
A vertebroplastia percutânea (VP) consiste na injeção de polimetilmetacrilato (PMMA) no corpo vertebral para alívio da dor e estabilização vertebral, porém seu uso na região cervical é restrito. No intuito de avaliar a efetividade e a segurança da VP na região cervical (VPC), foram avaliados 75 pacientes que se submeteram à VPC (n=101) por doença maligna (n=69) ou hemangioma vertebral (n=6) no período de janeiro de 1994 a outubro de 2007. A VPC foi realizada por uma abordagem ântero-lateral guiada por fluoroscopia. A dor foi graduada por uma escala variando de 0 a 10. O seguimento clinico (período médio de 8,8 meses) foi obtido em 57 (76%) pacientes: 48 tiveram a VPC indicada para controle da dor e nove para estabilização vertebral. Os dados foram analisados de forma univariada e multivariada. A efetividade analgésica foi obtida em 37 (77,1%) dos 48 pacientes seguidos, tendo sido associada ao volume de cimento injetado (P=0,011) e ao preenchimento vertebral (P=0,007) na análise multivariada. A estabilidade vertebral foi observada em 55 (96,5%) dos 57 pacientes, não se correlacionando com as variáveis estudadas. A curva de ROC identificou o preenchimento vertebral como preditor da efetividade analgésica (P=0,008), sendo 50% o melhor ponto de corte para discriminar a maior probabilidade de efetividade analgésica (sensibilidade de 78,0% e especificidade de 62,5%). O extravasamento de cimento foi identificado em 83 (82,2%) das 101 vértebras tratadas não se correlacionando com as variáveis estudadas. As complicações clínicas foram detectadas em 13 (17,3 %) pacientes: complicações locais em 10 (13,3%) e sistêmicas em três (4%) pacientes. As complicações clínicas foram estatisticamente relacionadas à ruptura do muro posterior (P=0,026) e ao extravasamento de PMMA no plexo venoso transverso (P=0,023). A taxa de mortalidade e morbidade a longo termo foi de 1,3% (um paciente) e 1,3% (um paciente). Pode se inferir que a VPC é um procedimento efetivo e seguro, sem se negligenciar os riscos potenciais de complicações. O preenchimento vertebral e o volume de cimento foram associados à efetividade analgésica, mas não à estabilidade vertebral. O preenchimento vertebral teve o maior poder discriminatório da efetividade analgésica, tendo sido obtido com o ponto de corte de 50 % o melhor equilíbrio entre sensibilidade e especificidade para se determinar a efetividade analgésica / Percutaneous vertebroplasty (PV) consists of an injection of polymethylmethacrylate (PMMA) into the vertebral body for pain relief and spinal stabilization, however reports of PV in the cervical spine (CPV) are scarce in the literature. To evaluate the effectiveness and security of CPV, we evaluated 75 patients (mean age, 51.3 years) who underwent CPV (n=101) for malignancies (n=69) and vertebral hemangiomas (n=6) between January 1994 and October 2007. CPV was performed via an antero-lateral approach, using fluoroscopic guidance. Pain intensity was scored with a scale ranging from 0 to 10. Follow-up (mean time of 8.8 months) was avaible in 57 (76 %) patients: 48 of them had CPV indicated for pain control and nine for spinal stabilization. Data were analysed by means of univariate and multivariate analysis. Pain improvement was observed in 37 (77.1%) out of 48 followed patients and was correlated in multivariate analysis with cement volume (P=0.011) and with vertebral filling (P=0.007). Spinal stabilization was observed in 55 (96.5%) of 57 followed patients and was related with none of the evaluated variables. The ROC curve identified the vertebral filling as a good predictor of pain improvement (P=0.008). The best cut-off point to discriminate pain improvement was 50% of vertebral filling (78.0% sensitivity and 62.5% specificity). In 83 (82.2%) of the 101 treated vertebral levels, at least one type of PMMA leakage was found. None of the evaluated factors were related significantly to PMMA leakage. Clinical complications were detected in 13 (17.3%) patients: local complications in 10 (13.3%) patients and systemic clinical complications in three (4.0%) patients. Posterior wall disruption (P=0.026) and transverse venous PMMA leakage (P=0.023) were significantly associated with clinical complications. Long-term morbidity and mortality rate was 1.3% (one patient) and 1.3% (one patient). CPV is a safe and efficacious procedure, but the potential for local and systemic complications must be considered. Cement volume and vertebral filling were associated with pain improvement but not with spinal stability. Vertebral filling has a good performance to predict pain improvement and a cut-off of 50% of vertebral filing obtained the best compromise between sensitivity and specificity to discriminate pain improvement
5

Resultados da vertebroplastia percutânea na doença vertebral cervical / Results of percutaneous vertebroplasty in the cervical spine

Francisco José Arruda Mont'Alverne 17 November 2008 (has links)
A vertebroplastia percutânea (VP) consiste na injeção de polimetilmetacrilato (PMMA) no corpo vertebral para alívio da dor e estabilização vertebral, porém seu uso na região cervical é restrito. No intuito de avaliar a efetividade e a segurança da VP na região cervical (VPC), foram avaliados 75 pacientes que se submeteram à VPC (n=101) por doença maligna (n=69) ou hemangioma vertebral (n=6) no período de janeiro de 1994 a outubro de 2007. A VPC foi realizada por uma abordagem ântero-lateral guiada por fluoroscopia. A dor foi graduada por uma escala variando de 0 a 10. O seguimento clinico (período médio de 8,8 meses) foi obtido em 57 (76%) pacientes: 48 tiveram a VPC indicada para controle da dor e nove para estabilização vertebral. Os dados foram analisados de forma univariada e multivariada. A efetividade analgésica foi obtida em 37 (77,1%) dos 48 pacientes seguidos, tendo sido associada ao volume de cimento injetado (P=0,011) e ao preenchimento vertebral (P=0,007) na análise multivariada. A estabilidade vertebral foi observada em 55 (96,5%) dos 57 pacientes, não se correlacionando com as variáveis estudadas. A curva de ROC identificou o preenchimento vertebral como preditor da efetividade analgésica (P=0,008), sendo 50% o melhor ponto de corte para discriminar a maior probabilidade de efetividade analgésica (sensibilidade de 78,0% e especificidade de 62,5%). O extravasamento de cimento foi identificado em 83 (82,2%) das 101 vértebras tratadas não se correlacionando com as variáveis estudadas. As complicações clínicas foram detectadas em 13 (17,3 %) pacientes: complicações locais em 10 (13,3%) e sistêmicas em três (4%) pacientes. As complicações clínicas foram estatisticamente relacionadas à ruptura do muro posterior (P=0,026) e ao extravasamento de PMMA no plexo venoso transverso (P=0,023). A taxa de mortalidade e morbidade a longo termo foi de 1,3% (um paciente) e 1,3% (um paciente). Pode se inferir que a VPC é um procedimento efetivo e seguro, sem se negligenciar os riscos potenciais de complicações. O preenchimento vertebral e o volume de cimento foram associados à efetividade analgésica, mas não à estabilidade vertebral. O preenchimento vertebral teve o maior poder discriminatório da efetividade analgésica, tendo sido obtido com o ponto de corte de 50 % o melhor equilíbrio entre sensibilidade e especificidade para se determinar a efetividade analgésica / Percutaneous vertebroplasty (PV) consists of an injection of polymethylmethacrylate (PMMA) into the vertebral body for pain relief and spinal stabilization, however reports of PV in the cervical spine (CPV) are scarce in the literature. To evaluate the effectiveness and security of CPV, we evaluated 75 patients (mean age, 51.3 years) who underwent CPV (n=101) for malignancies (n=69) and vertebral hemangiomas (n=6) between January 1994 and October 2007. CPV was performed via an antero-lateral approach, using fluoroscopic guidance. Pain intensity was scored with a scale ranging from 0 to 10. Follow-up (mean time of 8.8 months) was avaible in 57 (76 %) patients: 48 of them had CPV indicated for pain control and nine for spinal stabilization. Data were analysed by means of univariate and multivariate analysis. Pain improvement was observed in 37 (77.1%) out of 48 followed patients and was correlated in multivariate analysis with cement volume (P=0.011) and with vertebral filling (P=0.007). Spinal stabilization was observed in 55 (96.5%) of 57 followed patients and was related with none of the evaluated variables. The ROC curve identified the vertebral filling as a good predictor of pain improvement (P=0.008). The best cut-off point to discriminate pain improvement was 50% of vertebral filling (78.0% sensitivity and 62.5% specificity). In 83 (82.2%) of the 101 treated vertebral levels, at least one type of PMMA leakage was found. None of the evaluated factors were related significantly to PMMA leakage. Clinical complications were detected in 13 (17.3%) patients: local complications in 10 (13.3%) patients and systemic clinical complications in three (4.0%) patients. Posterior wall disruption (P=0.026) and transverse venous PMMA leakage (P=0.023) were significantly associated with clinical complications. Long-term morbidity and mortality rate was 1.3% (one patient) and 1.3% (one patient). CPV is a safe and efficacious procedure, but the potential for local and systemic complications must be considered. Cement volume and vertebral filling were associated with pain improvement but not with spinal stability. Vertebral filling has a good performance to predict pain improvement and a cut-off of 50% of vertebral filing obtained the best compromise between sensitivity and specificity to discriminate pain improvement
6

Estudo experimental dos efeitos da embolização renal com partículas de trisacryl e de polivinil acetato recoberto com polivinil álcool / Experimental study of effects of renal embolization with trisacryl particles and polivinyl alcohol covered polivinyl acetate

Barbosa, Leandro de Assis 06 October 2009 (has links)
A embolização intra-arterial é rotineiramente utilizada na prática clinica como co-adjuvante pré-operatório ou controle de tumores, tratamento de malformações arteriovenosas e outras doenças vasculares. Em vários casos é realizada com uso de partículas de diferentes formas e composições. Um agente embolizante esférico e utilizado com bons resultados é o trisacryl (Embosphere®; BioSphere® Medical). Um novo agente embólico - polivinil acetato esférico cobertas com polivinil álcool (PVAc) foi desenvolvido recentemente no Brasil. Este trabalho tem objetivo de avaliar, após embolização renal, o grau de oclusão vascular, recanalização da luz vascular e a necrose da parede vascular provocados por partículas de PVAc, utilizando como parâmetro partículas de trisacryl. Setenta e nove fêmeas de coelhos do tipo albino New Zealand foram submetidas a cateterização arterial do rim direito; trinta e três animais foram embolizados com trisacryl, trinta e um com PVAc e quinze animais compuseram o grupo de simulação, tendo sido excluídos quatro animais (três trisacryl e um PVAc) devido a óbito precoce. Foram criados cinco subgrupos de seis animais, que foram sacrificados após 48 horas, 5 dias, 10 dias, 30 dias e 90 dias após a embolização. O grupo de simulação seguiu a mesma ordem temporal com três animais em cada grupo. As técnicas de coloração utilizadas foram os métodos de hematoxilina-eosina (HE) e tricrômico de Masson com observação por microscopia óptica. Os resultados mostraram diferença significativa entre o grau de oclusão vascular nos grupos de 5 dias e 10 dias e necrose no grupo de 48 horas em favor do grupo embolizado com PVAc, que apresentou reação tecidual adequada (redução volumétrica e isquemia) e menor grau de recanalização que o trisacryl / Intra-arterial embolization is often utilized in medical practice preoperatively as adjuvant in controlling tumors, treatment of arteriovenous malformations and other vascular diseases. Often times, particles of different forms and compositions are employed. trisacryl (Embosphere®; BioSphere® Medical), a spheric embolic agent, is nowadays used with very satisfactory results. However, a new embolic agent spheric polyvinyl alcohol-covered polivinyl acetate (PVAc)- has been developed in Brazil. This study evaluates the degree of vascular occlusion, vascular recanalization and the necrosis of vascular wall caused by PVAc particles, compared with trisacryl, after renal embolization. Seventy-nine female albine New Zealand rabbits underwent arterial catheterization of the right kidney; Thirty-three animals were embolized with trisacryl, thirty-one with PVAc and fifteen were kept as control group, four animals were excluded (three trisacryl and one PVAc) due to early death. Five subgroups of six animals were created. The animals in the different groups were sacrificed 48 hours, 5 days, 10 days, 30 days and 90 days after embolization. The control group was divided into subgroups of three animals, for the same period of time. Their kidneys were dyed with hematoxylin-eosin (HE) and Masson tricromic and examined using optic microscopy. The results showed a significant difference between the five-day and ten-day groups with regard to the degree of vascular occlusion, and the amount of necrosis in the forty-eight-hour group. Both findings favor the PVAc group, with adequate tissue reaction (ischemia and volumetric reduction) and less recanalization than with trisacryl
7

Estudo experimental dos efeitos da embolização renal com partículas de trisacryl e de polivinil acetato recoberto com polivinil álcool / Experimental study of effects of renal embolization with trisacryl particles and polivinyl alcohol covered polivinyl acetate

Leandro de Assis Barbosa 06 October 2009 (has links)
A embolização intra-arterial é rotineiramente utilizada na prática clinica como co-adjuvante pré-operatório ou controle de tumores, tratamento de malformações arteriovenosas e outras doenças vasculares. Em vários casos é realizada com uso de partículas de diferentes formas e composições. Um agente embolizante esférico e utilizado com bons resultados é o trisacryl (Embosphere®; BioSphere® Medical). Um novo agente embólico - polivinil acetato esférico cobertas com polivinil álcool (PVAc) foi desenvolvido recentemente no Brasil. Este trabalho tem objetivo de avaliar, após embolização renal, o grau de oclusão vascular, recanalização da luz vascular e a necrose da parede vascular provocados por partículas de PVAc, utilizando como parâmetro partículas de trisacryl. Setenta e nove fêmeas de coelhos do tipo albino New Zealand foram submetidas a cateterização arterial do rim direito; trinta e três animais foram embolizados com trisacryl, trinta e um com PVAc e quinze animais compuseram o grupo de simulação, tendo sido excluídos quatro animais (três trisacryl e um PVAc) devido a óbito precoce. Foram criados cinco subgrupos de seis animais, que foram sacrificados após 48 horas, 5 dias, 10 dias, 30 dias e 90 dias após a embolização. O grupo de simulação seguiu a mesma ordem temporal com três animais em cada grupo. As técnicas de coloração utilizadas foram os métodos de hematoxilina-eosina (HE) e tricrômico de Masson com observação por microscopia óptica. Os resultados mostraram diferença significativa entre o grau de oclusão vascular nos grupos de 5 dias e 10 dias e necrose no grupo de 48 horas em favor do grupo embolizado com PVAc, que apresentou reação tecidual adequada (redução volumétrica e isquemia) e menor grau de recanalização que o trisacryl / Intra-arterial embolization is often utilized in medical practice preoperatively as adjuvant in controlling tumors, treatment of arteriovenous malformations and other vascular diseases. Often times, particles of different forms and compositions are employed. trisacryl (Embosphere®; BioSphere® Medical), a spheric embolic agent, is nowadays used with very satisfactory results. However, a new embolic agent spheric polyvinyl alcohol-covered polivinyl acetate (PVAc)- has been developed in Brazil. This study evaluates the degree of vascular occlusion, vascular recanalization and the necrosis of vascular wall caused by PVAc particles, compared with trisacryl, after renal embolization. Seventy-nine female albine New Zealand rabbits underwent arterial catheterization of the right kidney; Thirty-three animals were embolized with trisacryl, thirty-one with PVAc and fifteen were kept as control group, four animals were excluded (three trisacryl and one PVAc) due to early death. Five subgroups of six animals were created. The animals in the different groups were sacrificed 48 hours, 5 days, 10 days, 30 days and 90 days after embolization. The control group was divided into subgroups of three animals, for the same period of time. Their kidneys were dyed with hematoxylin-eosin (HE) and Masson tricromic and examined using optic microscopy. The results showed a significant difference between the five-day and ten-day groups with regard to the degree of vascular occlusion, and the amount of necrosis in the forty-eight-hour group. Both findings favor the PVAc group, with adequate tissue reaction (ischemia and volumetric reduction) and less recanalization than with trisacryl
8

Avaliação tomográfica dos parâmetros anatômicos relevantes na punção renal percutânea nos decúbitos ventral e dorsal

Arvellos, André Noronha 26 August 2011 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-07-18T11:25:20Z No. of bitstreams: 1 andrenoronhaarvellos.pdf: 6808287 bytes, checksum: 93e22153b8dde05493e1fda7161ac573 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-07-22T15:00:04Z (GMT) No. of bitstreams: 1 andrenoronhaarvellos.pdf: 6808287 bytes, checksum: 93e22153b8dde05493e1fda7161ac573 (MD5) / Made available in DSpace on 2016-07-22T15:00:04Z (GMT). No. of bitstreams: 1 andrenoronhaarvellos.pdf: 6808287 bytes, checksum: 93e22153b8dde05493e1fda7161ac573 (MD5) Previous issue date: 2011-08-26 / Introdução: Impulsionada pelo crescimento da endourologia, a busca de novas técnicas para o acesso percutâneo, com intuito de tornar o procedimento ainda menos invasivo e mais seguro, teve como marco os trabalhos de Valdivia Uría, que propôs e descreveu primeiramente a técnica de punção do paciente em decúbito dorsal inclinado, mostrando menor tempo de procedimento e melhora nos parâmetros cardiorrespiratórios durante sua realização em relação à técnica clássica em decúbito ventral, com sucesso terapêutico e morbidade semelhantes. Mesmo após mais de 20 anos da descrição da sua técnica e com a publicação de outras séries de casos por outros autores, a mesma não teve a difusão esperada. Pacientes e métodos: Foi realizada análise de exames de tomografia computadorizada de 71 pacientes através de simulações de nefrostomia percutânea nos decúbitos dorsal e ventral, correlacionando-se os resultados com variáveis antropométricas e quantificação da gordura abdominal no seu padrão de distribuição nos compartimentos visceral e subcutâneo. Resultados: Não houve diferença estatística entre o número de lesões de órgãos abdominais para os diferentes decúbitos nas simulações realizadas no plano axial (p=0,5621). Nas simulações oblíquas, os resultados mostraram significância estatística da diferença do decúbito no risco de lesão, sendo o resultado desfavorável ao decúbito ventral (p=0,0295). O órgão mais freqüentemente sob risco foi o cólon, seguido de longe pelo intestino delgado. A avaliação indireta do risco de lesão através de medidas da distância do cólon ao rim mostrou maior proximidade destes na posição de decúbito ventral, para ambos os lados, de forma estatisticamente significativa. Quanto à metodologia de análise, observou-se maior número de lesões nas simulações realizadas no plano axial do que nas simulações oblíquas tanto no decúbito ventral (p= 0,0274) como no dorsal (p= 0,0002). Nas simulações no plano axial, os pacientes que tiveram órgãos lesados mostraram de forma estatisticamente significativa menores peso, índice de massa corpórea (IMC) e quantidade de gordura visceral independente do decúbito. No plano oblíquo, não foi observada associação estatística com tais variáveis. Conclusão: Houve maior risco de lesão de órgãos abdominais (principalmente o cólon) no decúbito ventral, tanto através das simulações de punção, quanto através da análise indireta de risco através das medidas de proximidade do cólon com o rim. A metodologia com as simulações no plano oblíquo mostrou-se mais adequada, com resultados mais próximos das grandes séries de casos onde o procedimento foi realizado. Em relação aos dados antropométricos e padrão de distribuição da gordura abdominal por tomografia computadorizada (TC), os pacientes que tiveram órgãos lesados apresentaram de forma estatisticamente significativa menores peso, IMC e área de gordura visceral nas simulações no plano axial, para a análise conjunta das metodologias em ambos os decúbitos e para a análise conjunta da ocorrência independente da metodologia ou do decúbito. Na metodologia de análise no plano oblíquo, os baixos valores de p para as variáveis peso (0,07) e IMC (0,06) podem representar uma tendência em relação ao risco de lesão, talvez com significância estatística limitada pelo tamanho da amostra. / Introduction: The search for less invasive and safer techniques of percutaneous access in endourology had, as landmark, the studies undergone by Valdivia Uria, who first proposed and described access through the inclined supine position, with shortened procedure time and better cardiorespiratory parameters, compared with the traditional access in the prone position, and also showing similar success and morbidity rates. Although more than 20 years have elapsed since the first publication of the technique, and despite publications by other authors, the technique has not been so widely embraced as expected. Patients and methods: 71 patients underwent simulated percutaneous nephrostomy through computed tomography (CT), in both the supine and prone positions. The results were correlated with anthropometric variables and quantification of abdominal fat distribution in the visceral and subcutaneous compartments. Results: There was no statistical difference between the number of abdominal organ injuries in the two different positions in the axial plane (p=0.5621). In oblique simulations, the difference in the risk of injury to abdominal organs was statistically significant between the two positions, with more injuries happening in the prone position (p=0.0295). The colon was the most frequently injured organ, followed by the small intestine in a distant second. Indirect injury risk assessment by measurement of the colon-kidney distance showed statistically significant greater proximity of these organs in the the prone position, on both sides. Concerning the analysis methodology, there were a greater number of injuries in the axial plane than in the oblique simulations, both in the prone position (p=0.0274) and in the supine position (p=0.0002). In the axial plane simulations, patients who suffered organ injuries had statistically significant lower weight, Body Mass Index (BMI) and visceral fat amount, regardless of the position. In the oblique plane, no such statistical association was found. Conclusion: There was greater risk of injury to abdominal organs (mainly the colon) in the prone position, both in puncture simulations and in indirect risk assessment of risk through the measurement of the colon-kidney distance. Simulation in the oblique plane was the most adequate method, as it provided results that were closer to the ones from large case series in which the procedure was performed. Concerning the anthropometric factors and the pattern of CT-assessed abdominal fat distribution, patients who suffered organ injuries had statistically significant lower weight, BMI and visceral fat amount, in the axial plane, for analysis of the two methods in both positions and for analysis of the injuries regardless of method and position. In the oblique plane analysis methodology the low p values for weight (0.07) and BMI (0.06) may represent a tendency towards the injury risk, maybe with a limited statistical significance owing to the sample size.
9

Tratamento endovascular das fístulas carotidocavenosas indiretas / Endovascular treatment of indirect carotid-cavernous fistulas

Silva, André Goyanna Pinheiro 27 November 2006 (has links)
As fístulas arteriovenosas da região do seio cavernoso constituem as fístulas carotidocavernosas que podem ser diretas ou indiretas. As indiretas são raras, a sua sintomatologia é variada e o tratamento é controverso. Este estudo compreendeu a análise prospectiva de 44 pacientes portadores de fístulas carotidocavernosas indiretas (FCCI) no período de 01 de janeiro de 1994 e 31 de janeiro de 2004, 42 com etiologia espontânea e dois pacientes com etiologia traumática, sendo estes analisados separadamente. Doze (12) pacientes foram submetidos à conduta expectante e orientados a realizar manobras de compressão carótido-jugular. O tratamento endovascular foi realizado por via arterial, venosa ou combinação dos dois, num total de 30 pacientes. Considerando o grupo inteiro, ocorreu trombose espontânea em aproximadamente 24% dos pacientes. Os sintomas e o aspecto angiográfico após o tratamento evoluíram com melhora ou cura em 100% dos casos, com oclusão completa das FCCI em 63,3%, a grande maioria destes submetidos a apenas um procedimento. Além dos acessos venosos tradicionais aos seios cavernosos, vias de acesso alternativas através da veia oftálmica superior foram realizadas por punção percutânea de veia facial, veia supratroclear ou veia frontal. O material embolizante mais utilizado foi o adesivo tissular líquido, \"cola\", isoladamente ou em conjunto com outros materiais. Houve complicações transitórias em 13,3% dos pacientes tratados e nenhuma complicação permanente foi observada, o que demonstrou a baixa morbidade deste procedimento / The arteriovenous fistulas of the cavernous sinus (CS) region constitute the carotid-cavernous fistula, which can be direct or indirect. The indirect type is quite rare, its clinical features is very inespecific and its treatment modalities controversial. Forty-four patients with indirect carotid-cavernous fistulas (ICCF) were studied in a prospective manner between January 1994 to January 2004, 42 with spontaneous etiology and 2 with traumatic etiology, being these analyzed separately. Twelve (12) patients were submitted to a expectant management and instructed to perform carotid-jugular compression. Endovascular treatment was accomplished by arterial approach, vein approach or combination of both, in a total of 30 patients. Considering the entire group, spontaneous thrombosis was observed in approximately 24%. Symptoms and the angiographic features after endovascular treatment improved or disappeared in 100% of the cases, with total obliteration in 63.3%, most of them submitted to just one procedure. Despite the traditional venous routes to the CS, alternative accesses through the superior ophthalmic vein (SOV) were accomplished by percutaneous puncture of the facial, supratrochlear or frontal vein. Liquid adhesive (glue) was the most often embolic material used isolated or with other materials. No permanent complication was observed and only 13,3% of the patients treated cursed with transitory complications, what demonstrated the low morbidity of this procedure
10

Caracterização das exposições ocupacionais e eficiência da dosimetria pessoal em radiologia intervencionista vascular

Bacchim Neto, Fernando Antonio. January 2017 (has links)
Orientador: Diana Rodrigues Pina / Resumo: A Radiologia Intervencionista (RI) é a área da medicina que proporciona as maiores exposições ocupacionais. Os valores de dose aos quais os intervencionistas são expostos são difíceis de padronizar. Nesta pesquisa apresentamos uma avaliação completa das exposições ocupacionais e determinamos a eficiência de distintos métodos de dosimetria pessoal utilizados na RI. Essa pesquisa foi abordada em 2 etapas, conforme descrito a seguir: A primeira etapa se baseou em caracterizar as exposições ocupacionais em diferentes modalidades de procedimentos de RI vascular para duas categorias de profissionais e estimar o número de procedimentos anuais que cada profissional pode realizar sem exceder os limites de dose. Foi avaliada a exposição ocupacional, através de dosimetria termoluminescente, em diferentes partes do corpo (cristalino, tireoide, tórax, abdômen, pés e mãos) de duas categorias de intervencionistas (principais e assistentes) em três modalidades diferentes de procedimentos de RI vascular. As maiores doses equivalentes foram encontradas para as mão de ambos os profissionais, podendo chegar a aproximadamente 9 mSv em um único procedimento. Algumas regiões dos profissionais em alguns procedimentos podem receber, durante o ano, níveis de doses perigosamente perto dos limites anuais. Dosímetros posicionados no tórax podem subestimar as doses para outras regiões do corpo, especialmente abdômen, extremidades e cristalinos. Na segunda etapa foram avaliadas as eficiências de 6 diferent... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Interventional Radiology (IR) is the area of medicine that provides the largest occupational exposures. The dose values to which interventionists are exposed are difficult to standardize. In this research we present a complete evaluation of occupational exposures and determine the efficiency of different personal dosimetry methods used in IR. This research was performed in 2 stages, as described below: The first step was to characterize the occupational exposures in different modalities of vascular IR procedures for two categories of professionals. We also estimated the number of annual procedures that each professional can perform without exceeding the dose limits. Occupational exposures were evaluated in different body parts (crystalline, thyroid, thorax, abdomen, feet and hands) by two interventional categories (primary and assistants) in three different modalities of vascular IR procedures. The highest equivalent doses were found for the hands of both professionals, reaching approximately 9 mSv in a single procedure. Some regions of professionals in some procedures may receive dose levels during the year dangerously close to annual limits. Dosimeters positioned in the chest may underestimate the doses to other regions of the body, especially the abdomen, extremities and crystalline. The second stage, we evaluated the efficiencies of 6 different personal dosimetry methodologies used internationally to estimate the effective dose received by interventional professionals. An... (Complete abstract click electronic access below) / Mestre

Page generated in 0.1143 seconds