• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 137
  • 1
  • 1
  • Tagged with
  • 139
  • 139
  • 57
  • 56
  • 52
  • 33
  • 32
  • 27
  • 27
  • 26
  • 25
  • 24
  • 24
  • 20
  • 16
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
131

Indução de mutação em sementes de arroz (Oryza sativa L.) e seleção de possíveis mutantes M2 para a dormência e tolerância ao frio na germinação / Mutation induction in rice seeds (Oryza sativa L.) and selection of putative M2 mutants for dormancy and germination under low temperature

Mansour, Daniela Hernandes 30 March 2006 (has links)
Made available in DSpace on 2014-08-20T13:44:38Z (GMT). No. of bitstreams: 1 dissertacao_introducao_daniela_mansour.pdf: 49223 bytes, checksum: 6acd632060a3e69b27bebae3deb1f727 (MD5) Previous issue date: 2006-03-30 / Cultivated in more than 150 million hectares, rice (Oryza sativa L.) is one of the most important crops around the world. In 2005 approximately 600 millions tons were harvested. Moreover, the rice grain is the basic food for at least four billion people worldwide. Rice breeding programs are looking for the development of new varieties with higher productivity, nutritionally traits and environment stresses tolerance. Initially using the existing variability to create new recombination, through artificial hybridizations, and, later, inducing mutations. The generation of a mutant population looking for selects putative mutants for dormancy and tolerance to low temperature during germination, may be contribute to know mechanisms involved in these traits, moreover in the future, it may be possible to develop new and better genotypes. The goal of this work was to generate a mutant population of rice from the BRS 7 Taim cultivar and to identify putative mutants for dormancy and germination under low temperature. Ten thousand seeds of the BRS 7 Taim cultivar were submitted to 250 Gy. The M1 seeds were cultivated in field to produce M2 seeds. Thirty M2 seed populations were harvested and evaluated. The mutation induction allowed the generation of a mutant bank with differentiated performance for dormancy and tolerance to low temperature in the germination. The M2 24 seed population seems to be the better one to study the dormancy trait. The M2 mutant populations showed different performance in the germination test under 13°C, however, it was no possible to select a putative M2 population based on the coleoptile length. / Cultivado em mais de 150 milhões de hectares, arroz (Oryza sativa L.), é um dos cereais mais produzidos e consumidos no mundo, com produção aproximada de 600 milhões de toneladas, se constitui no alimento básico para dois terços da população do planeta. Os programas de melhoramento genético do arroz buscam incrementar a produtividade e a qualidade, inicialmente aproveitando a variabilidade existente para criar novas recombinações, através de hibridações artificiais, e, posteriormente, induzindo mutações. A geração de uma população mutante com posterior seleção de possíveis mutantes para dormência e tolerância ao frio na germinação poderá contribuir para o entendimento dos mecanismos genéticos envolvidos nestes dois caracteres e para o futuro desenvolvimento de genótipos superiores. O trabalho teve por objetivo gerar uma população mutante de arroz a partir da cv. BRS 7 Taim e identificar possíveis mutantes para o caráter dormência e tolerância ao frio na germinação. Dez mil sementes da cultivar BRS 7 Taim foram submetidas a 250Gy de radiação gama. As sementes M1 foram cultivadas em campo para produção de populações de sementes M2. Trinta populações de sementes M2 foram avaliadas quanto à presença de sementes dormentes e tolerância ao frio na germinação. A indução de mutação permitiu gerar um banco de mutantes com desempenho diferenciado para os caracteres dormência e tolerância ao frio na germinação. A população de sementes M2 24 parece ser altamente promissora para o estudo do caráter dormência. As 30 populações M2 tiveram desempenho contrastante quanto ao percentual de germinação a 13°C, porém, a seleção de populações M2 para a tolerância ao frio na germinação, através da medida do comprimento do coleóptilo, não foi eficiente.
132

Caracterização morfofenológica e molecular de mutantes de arroz irrigado / Morphophenological and molecular characterization of irrigated rice mutants

Silva, Aline Scheer da 30 October 2013 (has links)
Made available in DSpace on 2014-08-20T13:59:07Z (GMT). No. of bitstreams: 1 tese_aline_scheer_da_silva.pdf: 990457 bytes, checksum: 3ed714ae04d7f441e614c03031fe7354 (MD5) Previous issue date: 2013-10-30 / Irrigated rice (Oryza sativa L.) presents a great economic and social importance, mainly in Brazil s southern region, which stimulates the search for more productive cultivars and with agronomic characteristics that meet market requirements. Support techniques to improvement programs, as induced mutations and use of molecular markers, are being increasingly used. Induced mutations are considered to be an alternative method in order to create genetic variability, being the use of ionizing radiation an effective technology with which mutants were obtained with characteristics of higher productivity, precocity, smaller, higher resistance to disease and pest infestation in different species, which are used in improvement programs to obtain new cultivars. AFLP is one of the most used molecular markers techniques to analyze genetic divergence in plant populations, mainly in species that present low rate of poliforfism in the DNA. The aim of this work was morphophenological and molecular characterization of mutants of rice derived from the BRS Querência and BRS Fronteira elite cultivars, which can turn into new cultivars or serve to crossings in rice breeding programs. In the 2009/2010 growing season, seeds of M1 plants (originated from seeds exposed to different doses of gamma radiation) were sown in trays containing soil typically found in rice culture, aiming seedling production. From two to three leaves, seedlings were transplanted to the field forming M2 population. In this generation, 59 mutants with agronomic characteristics of interest were selected. In the following growing season (2010/2011), seeds of these 59 mutant plants were sown and transplanted in the same previous conditions and formed M3 population. In all generations, morphophenologic descriptors of rice culture were evaluated. Genetic divergence among the mutant selected in generation M3 and the cultivar witnesses through the AFLP technique were also evaluated. The obtained data were submitted to analysis of variance, compared by means test (Dunnett) to 5% of probability. Multivariate analysis through GENES software were also performed (CRUZ, 2007). In both cultivars, mutants with characteristics of agronomic concern were obtained, such as reduction in culture cycle and in height of the plants, increase in thickness of the stem, greater tillering and panicle number, higher number of grains per panicle and higher 1000-grain weight. AFLP technique showed up to 51% dissimilarity among genotypes of the same origin, being M_CTT/ E_AAC the most informative primer combinations among the 13 combinations tested in this study. Based on the results that were obtained we conclude that some of the mutants obtained can be used in the future for gene action studies, crossings and/or to launch a new cultivar. / O arroz irrigado (Oryza sativa L.) apresenta grande importância econômica e social, principalmente na região sul do Brasil, fato que estimula a busca por cultivares mais produtivas e com características agronômicas que atendam as exigências de mercado. Técnicas de apoio aos programas de melhoramento, como mutações induzidas e uso de marcadores moleculares estão sendo cada vez mais utilizadas. A indução de mutações é considerada um método alternativo para criar variabilidade genética, sendo o uso de radiações ionizantes uma tecnologia eficaz, com a qual foram obtidos mutantes com características de maior produtividade, precocidade, menor porte, maior resistência às doenças e pragas em diferentes espécies, os quais são utilizados nos programas de melhoramento na obtenção de novas cultivares. AFLP é uma das técnicas de marcadores moleculares mais utilizadas para analisar divergência genética em populações de plantas, principalmente em espécies que apresentam baixa taxa de poliforfismo no DNA. O presente trabalho teve como objetivo a caracterização morfofenológica e molecular de mutantes de arroz irrigado oriundos das cultivares elite BRS Querência e BRS Fronteira, os quais poderão se transformar em novas cultivares ou servirem para cruzamentos nos programas de melhoramento de arroz. Na safra 2009/2010 sementes de plantas M1 (originadas de sementes expostas à diferentes doses de radiação gama) foram semeadas em bandejas contendo solo típico da cultura do arroz, visando à produção de mudas. No estádio de duas a três folhas as mudas foram transplantadas para o campo formando a população M2. Nesta geração foram selecionadas 59 mutantes com características agronômicas de interesse. Na safra seguinte (2010/2011), sementes destas 59 plantas mutantes foram semeadas e transplantadas nas mesmas condições anteriores e formaram a população M3. Em todas gerações foram avaliados os descritores morfofenólógicos da cultura do arroz, foi também avaliada a divergência genética entre os mutantes selecionados na geração M3 e as cultivares testemunhas pela técnica de AFLP. Os dados obtidos foram submetidos à análise de variância, comparados pelo teste de médias (Dunnett) a 5% de probabilidade, foi realizada também análises multivariadas através do programa GENES (CRUZ, 2007). Em ambas cultivares foram obtidos mutantes com características de interesse agronômico, como redução no ciclo da cultura e na altura das plantas, incremento na espessura do colmo, maior perfilhamento e número de panículas, maior número de grãos por panícula e maior peso de 1000 grãos. A técnica AFLP mostrou até 51% de dissimilaridade entres os genótipos de mesma origem, sendo M_CTT/E_AAC a combinação de primers mais informativa entre as 13 combinações testadas neste estudo. Com base nos resultados obtidos, conclui-se que alguns dos mutantes obtidos poderão ser utilizados futuramente para estudos de ação gênica, cruzamentos e/ou para o lançamento de uma nova cultivar.
133

Implementação de um sistema eletrônico para medir taxa de fluência de energia de radiação na faixa de radioterapia com sensor piroelétrico /

Pontes, Wesley. January 2011 (has links)
Orientador: Aparecido Augusto de Carvalho / Banca: Cláudio Kitano / Banca: Walter Katsumi Sakamoto / Banca: Tony Inácio da Silva / Banca: Giuliano Pierre Estevam / Resumo: Sensores piroelétricos podem ser utilizados para medir a taxa de fluência de energia (intensidade) da radiação X na faixa de diagnóstico médico e de ortovoltagem. Neste trabalho, foi implementado um sistema eletrônico que pode medir taxa de fluência de energia de radiação gama de 1,25 MeV e fótons X de 6 MV e 15 MV. O sistema é constituído por um sensor piroelétrico, um conversor corrente-tensão de alta sensibilidade e um instrumento para registrar a forma de onda e medir o pulso do sinal produzido pelo sensor. Este instrumento pode ser um osciloscópio, um circuito microcontrolado associado a um display de cristal líquido, ou um módulo de aquisição de dados e um laptop. O sensor piroelétrico e o conversor corrente-tensão foram alojados em uma câmara piroelétrica blindada. Seis tipos de sensores piroelétricos foram avaliados, sendo três cerâmicas e três compósitos. Os resultados obtidos com o sistema eletrônico, utilizando os diferentes tipos de sensores, possibilitaram caracterizá-lo em termos de precisão, resolução e sensibilidade. O sistema apresentou resposta linear com a taxa de fluência de energia da radiação, precisão melhor que 3 % e resolução de 5,56 nW/m2. As constantes piezoelétricas d33 dos sensores utilizados não sofreram alteração após os mesmos terem sido irradiados com 45 Gy de radiação na faixa de radioterapia. Estas características, associadas à importância de se medir a taxa de fluência de energia de radiação ionizante, podem tornar o instrumento piroelétrico muito útil no monitoramento de radiação produzida por equipamentos de radioterapia / Abstract: Pyroelectric sensors have been be used to measure the energy fluence rate (intensity) of x-radiation in the range of medical diagnosis and orthovoltage. In this work, we implemented an electronic system that can measure the energy fluence rate of 1.25 MeV gamma radiation, 6 MV and 15 MV X-photons. The system consists of a pyroelectric sensor, a high sensitivity current-to-voltage converter and an instrument for measuring and recording the waveform of pulses produced by the pyroelectric sensor. This instrument may be an oscilloscope, a microcontrolled circuit associated with a liquid crystal display, or a data acquisition module connected to a laptop. The pyroelectric sensor and the current-tovoltage converter were placed in an shielded pyroelectric camera. Six types of pyroelectric sensors were evaluated, three ceramics and three composites. The results obtained with the electronic system, using different types of sensors, allowed us to characterize it in terms of precision, resolution and sensitivity. The system has linear response to the energy fluence rate of radiation, precision better than 3 % and resolution of 5,6 nW/m2. The piezoelectric constant d33 of the sensors used have not changed after these have been irradiated with 45 Gy of radiotherapy radiation. These characteristics, associated with the importance of measuring the ionizing radiation energy fluence rate may make the pyroelectric instrument very useful in monitoring radiation produced by radiotherapy equipments / Doutor
134

Implementação de um sistema eletrônico para medir taxa de fluência de energia de radiação na faixa de radioterapia com sensor piroelétrico

Pontes, Wesley [UNESP] 25 February 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:42Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-02-25Bitstream added on 2014-06-13T19:22:12Z : No. of bitstreams: 1 pontes_w_dr_ilha.pdf: 799811 bytes, checksum: 398dc35d3e3ae3ef3dfe294f8ba6793c (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Sensores piroelétricos podem ser utilizados para medir a taxa de fluência de energia (intensidade) da radiação X na faixa de diagnóstico médico e de ortovoltagem. Neste trabalho, foi implementado um sistema eletrônico que pode medir taxa de fluência de energia de radiação gama de 1,25 MeV e fótons X de 6 MV e 15 MV. O sistema é constituído por um sensor piroelétrico, um conversor corrente-tensão de alta sensibilidade e um instrumento para registrar a forma de onda e medir o pulso do sinal produzido pelo sensor. Este instrumento pode ser um osciloscópio, um circuito microcontrolado associado a um display de cristal líquido, ou um módulo de aquisição de dados e um laptop. O sensor piroelétrico e o conversor corrente-tensão foram alojados em uma câmara piroelétrica blindada. Seis tipos de sensores piroelétricos foram avaliados, sendo três cerâmicas e três compósitos. Os resultados obtidos com o sistema eletrônico, utilizando os diferentes tipos de sensores, possibilitaram caracterizá-lo em termos de precisão, resolução e sensibilidade. O sistema apresentou resposta linear com a taxa de fluência de energia da radiação, precisão melhor que 3 % e resolução de 5,56 nW/m2. As constantes piezoelétricas d33 dos sensores utilizados não sofreram alteração após os mesmos terem sido irradiados com 45 Gy de radiação na faixa de radioterapia. Estas características, associadas à importância de se medir a taxa de fluência de energia de radiação ionizante, podem tornar o instrumento piroelétrico muito útil no monitoramento de radiação produzida por equipamentos de radioterapia / Pyroelectric sensors have been be used to measure the energy fluence rate (intensity) of x-radiation in the range of medical diagnosis and orthovoltage. In this work, we implemented an electronic system that can measure the energy fluence rate of 1.25 MeV gamma radiation, 6 MV and 15 MV X-photons. The system consists of a pyroelectric sensor, a high sensitivity current-to-voltage converter and an instrument for measuring and recording the waveform of pulses produced by the pyroelectric sensor. This instrument may be an oscilloscope, a microcontrolled circuit associated with a liquid crystal display, or a data acquisition module connected to a laptop. The pyroelectric sensor and the current-tovoltage converter were placed in an shielded pyroelectric camera. Six types of pyroelectric sensors were evaluated, three ceramics and three composites. The results obtained with the electronic system, using different types of sensors, allowed us to characterize it in terms of precision, resolution and sensitivity. The system has linear response to the energy fluence rate of radiation, precision better than 3 % and resolution of 5,6 nW/m2. The piezoelectric constant d33 of the sensors used have not changed after these have been irradiated with 45 Gy of radiotherapy radiation. These characteristics, associated with the importance of measuring the ionizing radiation energy fluence rate may make the pyroelectric instrument very useful in monitoring radiation produced by radiotherapy equipments
135

Efeito da radiação gama sobre as propriedades mecânicas de compósito de fibras de sisal/poliuretana sem uso de agentes de acoplamento

Vasco, Marina Cardozo 24 October 2014 (has links)
Compósitos de fibras naturais com matriz polimérica tem sido foco de estudos por possuírem boas propriedades mecânicas e baixo peso, o que permite sua utilização em diversos meios, incluindo ambientes hospitalares, salas de radioterapia e radiodiagnóstico. Sua grande dificuldade é a falta de afinidade dos materiais componentes, causando distanciamento da interface e baixa transferência de carga entre a matriz e o reforço. Uma alternativa podem ser os compósitos à base de fibras naturais e poliuretana derivada do óleo de mamona. A incidência de radiação pode levar à degradação do material polimérico e à alteração de suas propriedades mecânicas. O objetivo do presente trabalho foi a obtenção e caracterização de compósitos de fibras dispersas e tecido de sisal com matriz poliuretana a base de óleo de mamona, sem adição de agentes de compatibilização, que possam ser utilizados em ambientes que recebam radiação em alta intensidade. Os compósitos foram obtidos por prensagem a frio, irradiados com radiação gama, dose de 25 kGy, e avaliados antes e após irradiação através de ensaios térmicos, de infravermelho, de superfície e mecânicos. Foi observado que pode haver afinidade química entre o material de reforço e a matriz, sendo que não foi evidenciado distanciamento da interface fibra/polímero. Os materiais obtidos podem ser considerados hidrofílicos pela análise de ângulo de contato. Foram obtidos valores máximos de tensão de flexão de 80,33 MPa e módulo elástico em flexão de 4,40 GPa para o compósito de tecido de sisal / poliuretana sem irradiação e resistência ao impacto de 13,14 kJ/m2 para o compósito de fibras dispersas de sisal após irradiação. Pode-se concluir que os materiais são adequados para utilização em salas de radioterapia e radiodiagnóstico. / Natural fiber composites with polymeric matrix has been the focus of studies by having good mechanical properties and low weight, which allows its use in various environments, including hospital, radiotherapy and radiology rooms. Its major difficulty is the lack of affinity of the component materials, causing detachment of the interface and lower load transfer between matrix and reinforcement. An alternative may be composites based on natural fibers and polyurethane derived from castor oil. The incidence of radiation can lead to degradation of polymeric material and change its mechanical properties. The objective of this study was to obtain and characterize composites of dispersed sisal fibers and sisal fabric with polyurethane matrix based on castor oil without addition of compatibilizing agents, which may be used in environments that receive radiation at high intensity. The composites were obtained by cold pressing, irradiated with gamma radiation, dose of 25 kGy, and evaluated before and after irradiation with thermal, infrared, surface and mechanical testing. It was observed that there may be chemical affinity between the reinforcing material and the matrix, since was not observed detachment from the fiber / polymer interface. The materials can be considered hydrophilic by contact angle analysis. Maximum values of bending stress of 80.33 MPa and elastic modulus in bending of 4.40 GPa for the sisal fabric / polyurethane composite without irradiation were obtained, such as impact resistance of 13.14 kJ / m2 for the dispersed sisal fibers composite after irradiation. It can be concluded that the materials are suitable for use in radiotherapy and radiology rooms.
136

Cálculo de dose na irradiação de corpo inteiro utilizando simuladores antropomórficos híbridos UF e o código MCNPX

Cunha, Julyanne Silva 18 February 2016 (has links)
Conselho Nacional de Pesquisa e Desenvolvimento Científico e Tecnológico - CNPq / Total Body Irradiation is a special technique of radiotherapy used for conditioning for bone marrow transplantation. Its function is to immunosuppression, bone marrow ablation and destruction of malignant cells. How it is the irradiation of a large and irregular field is necessary to seek ways to offset the tissues so that the absorbed dose to the patient's body has a uniformity of ± 10%. In addition, other factors intervene so that this condition is satisfied, such as the choice of radiation source, the posture of the patient, the incidence geometry, the distance of treatment, the combination of fields, among others. To analyze how these factors influence the dose distribution in the body, in this study we were simulated computationally scenarios of Total Body Irradiation, using telecobaltherapy units and linear accelerator of 6 MV, for an estimated equivalent and effective doses using the code MCNPX of radiation transport and hybrid anthropomorphic simulators UFHADF and UFHADM in sitting postures to RLAT and LLAT irradiation, and lying to the AP and PA projections. To validate the spectra used in the simulations was calculated PDP for comparison with experimental measurements. As for the validation of TBI scenarios were estimated entrance dose rates in skin also for comparison with experimental measurements. The PDP curves are shown according to the literature. The values of the estimated dose rates are less than 10% relative difference in relation to the experimental measurements, which allowed us to estimate the dose in the organs. The simulation results show that the lateral irradiations of UF simulators in the sitting posture offer a less uniform dose distribution compared to radiation AP / PA with the simulator in lying posture. For the PA irradiation geometry the absorbed dose in the red marrow is approximately 20% higher than in the AP projection, which suggests that the first case is most appropriate for the destruction of diseased marrow. Regarding the use of attenuators objects for radiation attenuation in the lung there was a reduction of 23% of the absorbed dose by this organ, which shows their effectiveness and importance to these procedures. It was also observed that the decrease in patient treatment away from the radiation source and the room walls leads to a near increase of 10% and 5%, respectively, the absorbed dose, which suggests that treatments be more suitable carried out great distances focus-surface and far from the room's walls. The energy beam used for Total Body Irradiation, the most significant differences between the Cobalt-60 and linear accelerator 6 MV spectra were up to 46.23%, which occurred for the AP irradiation geometry, where observed that the first deposits most of its energy near the surface, which shows that more energy beams for irradiation are more effective at greater depths. Another factor analyzed was the combination of adjacent and overlapping fields for the treatment, leading to overdoses in some organs and committed dose uniformity as observed by other authors. The calculation of the effective dose showed that there is a greater overall commitment of the body to radiation in LLAT incidence geometry. It was also found that the effective dose is higher in the AP projection than PA as found in the literature. The analyzes show the importance and suggest a more detailed study of the exposure conditions for planning treatments for TB / A Irradiação de Corpo Inteiro é uma técnica especial de radioterapia utilizada para o condicionamento de transplante de medula óssea. Sua função é de imunossupressão, ablação da medula e destruição de células malignas. Por se tratar da irradiação de um campo grande e irregular é necessário buscar meios para compensação dos tecidos para que a dose absorvida pelo corpo do paciente tenha uma uniformidade de ±10%. Além disso, outros fatores interferem para que essa condição seja satisfeita, tais como a escolha fonte de radiação, a postura do paciente, a geometria de incidência, a distância de tratamento, a combinação de campos, entre outros. Para analisar a maneira como esse fatores influenciam na distribuição da dose no corpo, neste trabalho foram simulados computacionalmente cenários de Irradiação de Corpo Inteiro, que utilizam unidades de telecobaltoterapia e aceleradores lineares de 6 MV, para a estimativa da doses equivalente e efetiva utilizando o código de transporte de radiação MCNPX e os simuladores antropomórficos híbridos UFHADF e UFHADM nas posturas sentada, para irradiações RLAT e LLAT, e deitada para as projeções AP e PA. Para a validação dos espectros utilizados nas simulações foi calculada a PDP para a comparação com medidas experimentais. Já para a validação dos cenários de TBI foram estimadas as taxas de dose de entrada na pele também para a comparação com medidas experimentais. As curvas de PDP se mostraram de acordo com a literatura. Os valores das taxas de dose estimadas apresentaram uma diferença relativa menor que 10% em relação às medidas experimentais, o que permitiu estimar a dose nos órgãos. Os resultados das simulações mostram que as irradiações laterais dos simuladores UF na postura sentada oferecem uma distribuição de dose menos uniforme se comparado às irradiações AP/PA com o simulador na postura deitada. Para a geometria de irradiação PA a dose absorvida na medula vermelha é aproximadamente 20% maior que na projeção AP, o que sugere que o primeiro caso seja mais adequado para a destruição da medula doente. Quanto ao uso de objetos compensadores para atenuação da radiação no pulmão houve uma redução da dose absorvida por esse órgão em 23%, o que mostra sua eficácia e importância para esses procedimentos. Também foi observado que a diminuição da distância de tratamento do paciente a fonte de radiação e das paredes da sala leva a um aumento próximo de 10% e de 5%, respectivamente, na dose absorvida, o que sugere que sejam mais adequados tratamentos realizados a grandes distâncias foco-superfície e distantes das paredes da sala. Quanto à energia do feixe utilizado para Irradiação de Corpo Inteiro, as diferenças mais significativas entre o Cobalto-60 e o espectro do acelerador linear de 6 MV foram de até 46,23%, o que ocorreu para a geometria de irradiação PA, onde é observado que o primeiro deposita a maior parte de sua energia próximo a superfície, o que mostra que feixes mais energéticos são mais eficazes para irradiação em profundidades maiores. Outro fator analisado foi a combinação de campos adjacentes e sobrepostos para o tratamento, o que levou a superdosagens em alguns órgãos e comprometeu a uniformidade da dose assim como observado por outros autores. Os cálculos da dose efetiva permitiram concluir que há um maior comprometimento geral do corpo para irradiações na geometria de incidência LLAT. Também foi encontrado que a dose efetiva é superior na projeção AP que em PA assim como encontrado na literatura. As análises feitas mostram a importância e sugerem um estudo mais detalhado das condições de exposição para o planejamento de tratamentos por TBI.
137

Vida-média do estado isomérico 7(-) do núcleo ímpar-ímpar 68Ga / Lifetime of the 7(-) isomeric state of the odd-odd nucleus 68Ga

Escudeiro, Rafael 13 April 2018 (has links)
Estados Nucleares isoméricos são estados que decaem com vidas-médias longas ( T1/2 > 10 ns) e revelam, em geral, uma grande mudança no momento angular no seu decaimento, um pequeno elemento de matriz ou uma baixa energia de transição. Através da medida da vida-média de estados nucleares é possível obter informações sobre a função de onda desse estado, representando um teste rigoroso para modelos nucleares. Neste trabalho foi utilizado um sistema desenvolvido no Laboratório Aberto de Física Nuclear (LAFN) da Universidade de São Paulo chamado SIStema para Medida de Estados Isoméricos (SISMEI), que utiliza coincidência atrasada entre partículas evaporadas numa reação nuclear e raios gama emitidos pelo estado isomérico. O SISMEI consiste de cintiladores plásticos para detecção das partículas, detectores de germânio hiperpuro (HPGe) e iodeto de sódio (NaI(Tl)) para raios gama, associados a uma eletrônica de coincidência, instalado no acelerador Pelletron (8UD) do LAFN. Neste trabalho, realizou-se um experimento para medir o estado isomérico 7(-) (E = 1229,87(4) keV) do 68Ga. A tomada de dados durou cerca de 80 horas com uma taxa de eventos de aproximadamente 80000 contagens por hora. O resultado obtido foi T 1/2 = 60, 8(11) ns, que é compatível com os resultados experimentais de outros trabalhos, porém, mais preciso. A estrutura desse núcleo foi calculada através do Modelo de Camadas em Larga Escala considerando-se duas interações residuais diferentes FPG e JUN45; os resultados foram comparados entre si, juntamente com os valores obtidos em outros trabalhos. Os cálculos realizados com o Modelo de Camadas reproduziram relativamente bem a energia e a ordem dos estados excitados do 68Ga, a interação FPG conseguiu descrever melhor a probabilidade de transição quadrupolar elétrica B(E2) diretamente ligada à vida-média do estado. / Isomeric nuclear states are nuclear states which decay with long lifetimes (T1/2 > 10 ns); their study generally reveals, a large change in angular momentum in its decay, a small matrix element or a small transition energy. By measuring lifetimes of isomeric states it is possible to obtain information about this states wave function, being a robust test for nuclear models. In this work, a system developed at the Laboratório Aberto de Fsica Nuclear (LAFN) of University of São Paulo called System for the Measurement of Isomeric States (SISMEI) was utilized. Delayed coincidence between evaporated particles in a nuclear reaction and the delayed gamma-rays emitted from the isomeric state was used to measure lifetimes. SISMEI is composed of plastic scintillators for particle detection, hiperpure germanium detectors (HPGe) and sodium iodide (NaI(Tl)) for gamma-ray detection, coupled to a coincidence system, located on 30A beam line of the Pelletron (8UD) accelerator - LAFN. In the present work, an experiment to measure the 7 (-) (E = 1229.87(4) keV) isomeric state of 68Ga was performed. The experiment took about 80 hours with an event rate of about 80000 counts per second. The measured value was T 1/2 = 60.8(11) ns, which is compatible, but more accurate, with experimental results of other authors. The nuclear structure of this nucleus was calculated with the Large Scale Shell Model by using two different residual interactions FPG and JUN45; the results were compared with the known values. The structure calculated with LSSM described the energy states and the order of excited states relatively well; the FPG interaction was capable to describe better the quadrupolar electrical transition probability B(E2), which is direct related to predicting the state lifetime.
138

Proposta metodol?gica para o imageamento, caracteriza??o, parametriza??o e gera??o de modelos virtuais de afloramentos

Souza, Anderson de Medeiros 31 January 2013 (has links)
Made available in DSpace on 2015-02-24T19:48:44Z (GMT). No. of bitstreams: 1 AndersonMS_TESE_inicio_pag69.pdf: 4445825 bytes, checksum: 1053632581a0015bab09d4146df22458 (MD5) Previous issue date: 2013-01-31 / Petr?leo Brasileiro SA - PETROBRAS / The aim of this work was to describe the methodological procedures that were mandatory to develop a 3D digital imaging of the external and internal geometry of the analogue outcrops from reservoirs and to build a Virtual Outcrop Model (VOM). The imaging process of the external geometry was acquired by using the Laser Scanner, the Geodesic GPS and the Total Station procedures. On the other hand, the imaging of the internal geometry was evaluated by GPR (Ground Penetrating Radar).The produced VOMs were adapted with much more detailed data with addition of the geological data and the gamma ray and permeability profiles. As a model for the use of the methodological procedures used on this work, the adapted VOM, two outcrops, located at the east part of the Parnaiba Basin, were selected. On the first one, rocks from the aeolian deposit of the Piaui Formation (Neo-carboniferous) and tidal flat deposits from the Pedra de Fogo Formation (Permian), which arises in a large outcrops located between Floriano and Teresina (Piau?), are present. The second area, located at the National Park of Sete Cidades, also at the Piau?, presents rocks from the Cabe?as Formation deposited in fluvial-deltaic systems during the Late Devonian. From the data of the adapted VOMs it was possible to identify lines, surfaces and 3D geometry, and therefore, quantify the geometry of interest. Among the found parameterization values, a table containing the thickness and width, obtained in canal and lobes deposits at the outcrop Pared?o and Biblioteca were the more relevant ones. In fact, this table can be used as an input for stochastic simulation of reservoirs. An example of the direct use of such table and their predicted radargrams was the identification of the bounding surface at the aeolian sites from the Piau? Formation. In spite of such radargrams supply only bi-dimensional data, the acquired lines followed of a mesh profile were used to add a third dimension to the imaging of the internal geometry. This phenomenon appears to be valid for all studied outcrops. As a conclusion, the tool here presented can became a new methodology in which the advantages of the digital imaging acquired from the Laser Scanner (precision, accuracy and speed of acquisition) were combined with the Total Station procedure (precision) using the classical digital photomosaic technique / Neste trabalho s?o apresentados os procedimentos metodol?gicos necess?rios para realizar o imageamento digital 3D da geometria externa e interna de afloramentos an?logos a reservat?rios, e elaborar seus Modelos Virtuais de Afloramentos (MVA). Para imagear a geometria externa foram utilizados o Laser Scanner, o GPS Geod?sico e a Esta??o Total, enquanto que para imagear a geometria interna foi utilizado o GPR. Nos MVA elaborados foram acrescidas ainda as informa??es geol?gicas e as obtidas nas perfilagens com raios gama e de permeabilidade. Como estudo de caso, para exemplificar os procedimentos metodol?gicos propostos, foram escolhidos dois conjuntos de afloramentos na borda leste da Bacia do Parna?ba. Na primeira ?rea ocorrem rochas de origem e?lica da Forma??o Piau? (Neocarbon?fero) e plan?cie de mar? da Forma??o Pedra de Fogo (Permiano), que afloram em um amplo corte de estrada, situado entre Floriano e Teresina (Piau?). A segunda ?rea, situada no Parque Nacional de Sete Cidades, tamb?m no Piau?, envolve rochas da Forma??o Cabe?as depositadas em sistemas fl?vio-deltaicos, durante o Neodevoniano. Com os MVA elaborados foi poss?vel identificar, linhas, superf?cies e geometrias 3D e, assim, quantificar as geometrias de interesse. Dentre as parametriza??es mais relevantes, ressaltam-se a tabela com valores de espessura e largura, obtidas em dep?sitos de canais e em lobos, nos afloramentos Pared?o e Biblioteca. Esta tabela pode ser utilizada como entrada (input) para simula??o estoc?stica de reservat?rios. Um exemplo da aplica??o direta dos radargramas interpretados foi a identifica??o de superf?cies limitantes, em dep?sitos e?licos, da Forma??o Piau?. Apesar dos radargramas oferecerem apenas dados bidimensionais, a aquisi??o de linhas distribu?das segundo uma malha acrescentou a terceira dimens?o ao imageamento das geometrias internas em todos os afloramentos estudados. ? ainda proposta uma nova metodologia que busca conciliar as vantagens obtidas com o imageamento digital com Laser Scanner (precis?o, acur?cia e velocidade de aquisi??o) e a Esta??o Total (precis?o), com o uso cl?ssico de fotomosaicos digitais
139

Vida-média do estado isomérico 7(-) do núcleo ímpar-ímpar 68Ga / Lifetime of the 7(-) isomeric state of the odd-odd nucleus 68Ga

Rafael Escudeiro 13 April 2018 (has links)
Estados Nucleares isoméricos são estados que decaem com vidas-médias longas ( T1/2 > 10 ns) e revelam, em geral, uma grande mudança no momento angular no seu decaimento, um pequeno elemento de matriz ou uma baixa energia de transição. Através da medida da vida-média de estados nucleares é possível obter informações sobre a função de onda desse estado, representando um teste rigoroso para modelos nucleares. Neste trabalho foi utilizado um sistema desenvolvido no Laboratório Aberto de Física Nuclear (LAFN) da Universidade de São Paulo chamado SIStema para Medida de Estados Isoméricos (SISMEI), que utiliza coincidência atrasada entre partículas evaporadas numa reação nuclear e raios gama emitidos pelo estado isomérico. O SISMEI consiste de cintiladores plásticos para detecção das partículas, detectores de germânio hiperpuro (HPGe) e iodeto de sódio (NaI(Tl)) para raios gama, associados a uma eletrônica de coincidência, instalado no acelerador Pelletron (8UD) do LAFN. Neste trabalho, realizou-se um experimento para medir o estado isomérico 7(-) (E = 1229,87(4) keV) do 68Ga. A tomada de dados durou cerca de 80 horas com uma taxa de eventos de aproximadamente 80000 contagens por hora. O resultado obtido foi T 1/2 = 60, 8(11) ns, que é compatível com os resultados experimentais de outros trabalhos, porém, mais preciso. A estrutura desse núcleo foi calculada através do Modelo de Camadas em Larga Escala considerando-se duas interações residuais diferentes FPG e JUN45; os resultados foram comparados entre si, juntamente com os valores obtidos em outros trabalhos. Os cálculos realizados com o Modelo de Camadas reproduziram relativamente bem a energia e a ordem dos estados excitados do 68Ga, a interação FPG conseguiu descrever melhor a probabilidade de transição quadrupolar elétrica B(E2) diretamente ligada à vida-média do estado. / Isomeric nuclear states are nuclear states which decay with long lifetimes (T1/2 > 10 ns); their study generally reveals, a large change in angular momentum in its decay, a small matrix element or a small transition energy. By measuring lifetimes of isomeric states it is possible to obtain information about this states wave function, being a robust test for nuclear models. In this work, a system developed at the Laboratório Aberto de Fsica Nuclear (LAFN) of University of São Paulo called System for the Measurement of Isomeric States (SISMEI) was utilized. Delayed coincidence between evaporated particles in a nuclear reaction and the delayed gamma-rays emitted from the isomeric state was used to measure lifetimes. SISMEI is composed of plastic scintillators for particle detection, hiperpure germanium detectors (HPGe) and sodium iodide (NaI(Tl)) for gamma-ray detection, coupled to a coincidence system, located on 30A beam line of the Pelletron (8UD) accelerator - LAFN. In the present work, an experiment to measure the 7 (-) (E = 1229.87(4) keV) isomeric state of 68Ga was performed. The experiment took about 80 hours with an event rate of about 80000 counts per second. The measured value was T 1/2 = 60.8(11) ns, which is compatible, but more accurate, with experimental results of other authors. The nuclear structure of this nucleus was calculated with the Large Scale Shell Model by using two different residual interactions FPG and JUN45; the results were compared with the known values. The structure calculated with LSSM described the energy states and the order of excited states relatively well; the FPG interaction was capable to describe better the quadrupolar electrical transition probability B(E2), which is direct related to predicting the state lifetime.

Page generated in 0.0496 seconds