• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 19
  • Tagged with
  • 19
  • 19
  • 13
  • 11
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Influência do diâmetro do forame apical e do calibre do instrumento endodôntico nas leituras odontométricas proporcionadas por dois aparelhos localizadores apicais / Influence of foramen diameter and endodontic instrument size on odontometry reading by two electronic apex locators

Baldi, Járcio Victório 17 June 2005 (has links)
Este estudo objetivou avaliar a influência do diâmetro do forame e do instrumento endodôntico na leitura odontométrica de dois aparelhos localizadores apicais eletrônicos. Foram utilizados 40 dentes incisivos inferiores, divididos em 4 grupos, de acordo com o diâmetro do forame apical (100, 200, 300 e 400 µm). Após a abertura coronária desses dentes e o acesso aos canais radiculares, realizou-se a medição do comprimento dos mesmos com auxílio de um microscópio clínico com ampliação de 7,8X, da incisal até que a ponta da lima surgisse no forame apical. Os dentes foram colocados em potes individuais contendo solução de ágar a 1% em solução salina de fosfato tamponado, mantendo-se cerca de 2/3 de suas raízes imersas na solução para que pudesse ser feita a leitura com o Root ZX® (J.Morita, Japão) e o NovApex® (Fórum, Israel). Os mesmos foram medidos com limas nº10 até que a distância de 0,5 mm do ápice fosse acusada no display dos aparelhos. Uma outra medida foi realizada nos dentes utilizando-se lima nº10 e limas com diâmetros correspondentes ao diâmetro dos forames (200µm, 300µm e 400µm). Para a análise estatística foi empregado o teste de Análise de Variância a dois critérios para o confronto global entre os aparelhos e o emprego da lima nº10 em todos os dentes e teste de Tukey para as comparações individuais. Os resultados demonstraram diferença estatística na precisão dos dois aparelhos com um resultado mais preciso para o Root ZX® (p<0,05). Dentes com forame, de menor diâmetro, apresentaram uma medida mais precisa com o localizador apical e dentes com forame de maior diâmetro apresentaram uma maior discrepância na medida. O emprego de limas tipo K nº10 nos dentes com forames de diâmetros maiores apresentaram maior precisão na medição quando comparadas às limas coincidentes aos diâmetros dos forames para o aparelho Root ZX®. Para o NovApex® esta correlação só passou a ocorrer a partir da lima nº40. / This study evaluated the influence of foramen diameter and endodontic instrument size on the odontometry reading of two electronic apical measuring devices. Forty mandibular incisors were used, which were divided into four groups according to the apical foramen diameter (100, 200, 300 and 400µm). After coronal opening of these teeth and access to the root canals, the root canal length was measured with aid of a clinical microscope with 7.8x magnification, from the incisal edge until the file tip reached the apical foramen. Ten teeth with 100-µm diameter were placed in individual jars containing 1% agar solution in phosphate-buffered saline, maintaining around 2/3 of their roots immersed in the solution to allow measurement with Root ZX (J. Morita, Japan) and NovApex (Forum, Israel). Teeth were measured with files n. 10 until the distance of 0.5mm from the apex was indicated by the device. Another measurement was performed on the other thirty teeth with files n. 10 and files with diameters corresponding to the foramen diameters (200µm, 300µm and 400µm). Statistical analysis was performed by two-way analysis of variance for overall comparison between the devices and employment of file n. 10 in all teeth, and Tukey test for individual comparisons. The results demonstrated statistical difference in the precision of both devices, with a more accurate result for Root ZX (p<0.05). Teeth with narrower foramina presented a more accurate measurement with the apical measuring device, and teeth with wider foramina presented larger discrepancy in the measurement. Utilization of K file n. 10 in teeth with wider foramina showed more accurate measurements compared to files with size corresponding to the foramen diameters with the Root ZX® device. With the NovApex® device, this correlation was only observed with file n. 40.
12

Influência do diâmetro do forame apical e do calibre do instrumento endodôntico nas leituras odontométricas proporcionadas por dois aparelhos localizadores apicais / Influence of foramen diameter and endodontic instrument size on odontometry reading by two electronic apex locators

Járcio Victório Baldi 17 June 2005 (has links)
Este estudo objetivou avaliar a influência do diâmetro do forame e do instrumento endodôntico na leitura odontométrica de dois aparelhos localizadores apicais eletrônicos. Foram utilizados 40 dentes incisivos inferiores, divididos em 4 grupos, de acordo com o diâmetro do forame apical (100, 200, 300 e 400 µm). Após a abertura coronária desses dentes e o acesso aos canais radiculares, realizou-se a medição do comprimento dos mesmos com auxílio de um microscópio clínico com ampliação de 7,8X, da incisal até que a ponta da lima surgisse no forame apical. Os dentes foram colocados em potes individuais contendo solução de ágar a 1% em solução salina de fosfato tamponado, mantendo-se cerca de 2/3 de suas raízes imersas na solução para que pudesse ser feita a leitura com o Root ZX® (J.Morita, Japão) e o NovApex® (Fórum, Israel). Os mesmos foram medidos com limas nº10 até que a distância de 0,5 mm do ápice fosse acusada no display dos aparelhos. Uma outra medida foi realizada nos dentes utilizando-se lima nº10 e limas com diâmetros correspondentes ao diâmetro dos forames (200µm, 300µm e 400µm). Para a análise estatística foi empregado o teste de Análise de Variância a dois critérios para o confronto global entre os aparelhos e o emprego da lima nº10 em todos os dentes e teste de Tukey para as comparações individuais. Os resultados demonstraram diferença estatística na precisão dos dois aparelhos com um resultado mais preciso para o Root ZX® (p<0,05). Dentes com forame, de menor diâmetro, apresentaram uma medida mais precisa com o localizador apical e dentes com forame de maior diâmetro apresentaram uma maior discrepância na medida. O emprego de limas tipo K nº10 nos dentes com forames de diâmetros maiores apresentaram maior precisão na medição quando comparadas às limas coincidentes aos diâmetros dos forames para o aparelho Root ZX®. Para o NovApex® esta correlação só passou a ocorrer a partir da lima nº40. / This study evaluated the influence of foramen diameter and endodontic instrument size on the odontometry reading of two electronic apical measuring devices. Forty mandibular incisors were used, which were divided into four groups according to the apical foramen diameter (100, 200, 300 and 400µm). After coronal opening of these teeth and access to the root canals, the root canal length was measured with aid of a clinical microscope with 7.8x magnification, from the incisal edge until the file tip reached the apical foramen. Ten teeth with 100-µm diameter were placed in individual jars containing 1% agar solution in phosphate-buffered saline, maintaining around 2/3 of their roots immersed in the solution to allow measurement with Root ZX (J. Morita, Japan) and NovApex (Forum, Israel). Teeth were measured with files n. 10 until the distance of 0.5mm from the apex was indicated by the device. Another measurement was performed on the other thirty teeth with files n. 10 and files with diameters corresponding to the foramen diameters (200µm, 300µm and 400µm). Statistical analysis was performed by two-way analysis of variance for overall comparison between the devices and employment of file n. 10 in all teeth, and Tukey test for individual comparisons. The results demonstrated statistical difference in the precision of both devices, with a more accurate result for Root ZX (p<0.05). Teeth with narrower foramina presented a more accurate measurement with the apical measuring device, and teeth with wider foramina presented larger discrepancy in the measurement. Utilization of K file n. 10 in teeth with wider foramina showed more accurate measurements compared to files with size corresponding to the foramen diameters with the Root ZX® device. With the NovApex® device, this correlation was only observed with file n. 40.
13

Avaliação da relação entre as raízes dos dentes posteriores e o assoalho do seio maxilar em pessoas sem e com fissura labiopalatina

Pagin, Otávio 10 August 2015 (has links)
O seio maxilar apresenta formato distinto e volume variável entre as pessoas e seu assoalho pode ser encontrado em íntimo contato com as raízes dos dentes posteriores, podendo haver protrusão dessas raízes em seu interior. Tal proximidade é de grande relevância frente aos casos de comunicação bucossinusal em potencial ou pela possibilidade de desenvolvimento de um quadro infeccioso de origem odontogênica, em que esse pode vir a se estender para o interior do seio maxilar. Existe uma ausência de trabalhos na literatura acerca da relação estabelecida entre dentes posteriores e o seio maxilar em pessoas com fissura labiopalatina. O objetivo do presente estudo foi identificar e comparar a relação entre o assoalho do seio maxilar e os ápices radiculares dos dentes posteriores em imagens de tomografia computadorizada de feixe cônico em pessoas sem fissura labiopalatina e com fissura transforame incisivo unilateral e bilateral. Foram avaliados 100 indivíduos sem anomalias craniofaciais e 112 com fissura transforame incisivo unilateral ou bilateral, não sindrômicos, utilizando o programa i-CAT® Vision, onde a relação estabelecida pelas estruturas foi convencionada sendo, tipo 0 ou ausência de contato entre as estruturas, tipo 1 ou relação de íntimo contato entre as estruturas sem protrusão radicular no interior do seio maxilar e tipo 2 ou relação de íntimo contato entre as estruturas com protrusão radicular no interior do seio maxilar. Foi utilizado o teste do qui-quadrado para comparar os achados entre os grupos estudados, considerando valor estatisticamente significante quando p&#x2264; 0,05. Foi avaliada a relação do assoalho do seio maxilar com 1679 dentes, totalizando 3664 raízes onde 1883 (51,3%) foram classificadas como tipo 0, 1456 (39,7%) tipo 1 e 325 (8,8%) do tipo 2. Houve diferença estatisticamente significante para a raiz palatina do dente 18 entre os grupos com fissura unilateral e bilateral (p = 0,011), para a raiz mesiovestibular do dente 18 entre os grupos sem fissura e fissura bilateral (p = 0,046), bem como entre os grupos com fissura unilateral e bilateral (p = 0,016) e para a raiz vestibular do dente 24 entre os grupos sem fissura e com fissura bilateral (p = 0,001). Pessoas com fissura transforame incisivo unilateral e bilateral tendem a apresentar maior ocorrência da raiz vestibular do dente 24 (p = 0,027) e mesiovestibular do dente 16 (p = 0,047) em proximidade com o seio maxilar quando comparadas às pessoas sem fissura. Pessoas com fissura transforame incisivo bilateral tendem a apresentar uma maior ocorrência de proximidade com o seio maxilar das raízes vestibular do dente 24 (p = 0,001) e mesiovestibular do dente 18 (p = 0,046) quando comparados às pessoas sem fissura. A avaliação das raízes dos dentes posteriores por meio de imagens de tomografia computadorizada de feixe cônico e sua relação com o seio maxilar oferecem detalhamento e precisão, contribuindo assim para a elaboração de um diagnóstico e plano de tratamento que visam minimizar os riscos de acidentes e complicações. / The maxillary sinus has a remarkable feature and a variable volume among people where the inferior wall may be found in an intimate relation with the posterior teeth roots protruding or not inside the antrum. This proximity is of great relevance considering a potential oroantral communication or the spreading of an odontogenic infection into the maxillary sinus. There is a lack of evidence into the literature regarding the relationship between posterior teeth roots and the maxillary sinus in non-syndromic complete cleft lip and palate patients. This study aimed to evaluate and compare cone beam computed tomography images regarding the relationship between the posterior teeth roots and the maxillary sinus floor in non-cleft lip and palate patients and non-syndromic complete unilateral and bilateral cleft lip and palate patients. Images were interpreted using the i-CAT® Vision software including 100 noncleft patients and 112 presenting non-syndromic complete unilateral and bilateral cleft lip and palate. The relationship between teeth roots and the maxillary sinus floor was established as type 0 or no contact between these structures, type 1 or close contact without root protrusion into the sinus and type 2 or close contact with root protrusion into the sinus. The chi-square test, considering a statistically significant value where p&#x2264;0,05, was used to compare data between different groups. The sample included 1679 teeth and 3664 roots where 1883 (51,3%) were classified as type 0, 1456 (39,7%) as type 1 and 325 (8,8%) as type 2. There were statistically significant differences for tooth 18 palatine root between both complete cleft lip and palate groups (p = 0,011), for tooth 18 mesiobuccal root between noncleft and the bilateral groups (p = 0,046) and between both complete cleft lip and palate groups (p = 0,016) and for tooth 24 buccal root between non-cleft and the bilateral group (p = 0,001). Complete unilateral and bilateral cleft lip and palate patients presented a higher occurrence when compared with the non-cleft group of the tooth 24 buccal root (p = 0,027) and the tooth 16 mesiobuccal root (p = 0,047) in proximity with the maxillary sinus. Complete bilateral cleft lip and palate patients had a higher occurrence when compared with the non-cleft group of the tooth 24 buccal root (p = 0,001) and the tooth 18 mesiobuccal root (p = 0,046) in proximity with the sinus floor. The posterior teeth roots relationship with the maxillary sinus floor is better depicted and accurate by cone beam computed tomography images that may collaborated for a diagnosis and treatment planning that reduces the risks.
14

Viabilidade da substituição de raízes de dentes humanos por raízes construídas em compósito para estudos de mecânica da fratura / Viability of replacing the roots of human teeth by roots made of composite for the study of fracture mechanics

Espósito, Camila Oliveira Moraes 27 April 2012 (has links)
OBJETIVO: A restauração de dentes tratados endodonticamente é um desafio para a Odontologia. A fratura do remanescente radicular é comum neste tratamento. São três os métodos utilizados para estudar as fraturas: a análise por elementos finitos, os que utilizam dentes naturais e aqueles que utilizam dentes artificiais. O uso de dentes naturais apresenta alguns inconvenientes, como as variações anatômicas e de histórico de exposição a esforços (que aumentam a variabilidade da amostra e dificultam as conclusões), além da pequena disponibilidade de espécimes. Este estudo propõe-se avaliar a viabilidade de usar compósito para a construção de raízes artificiais e a aplicação dessas réplicas em estudos sobre a essas fraturas. MÉTODOS: Na primeira etapa foram utilizadas 50 raízes unirradiculares de 2º pré-molar superior e 50 réplicas. As raízes naturais foram selecionadas por terem características anatômicas semelhantes. As réplicas foram confeccionadas a partir de um molde de resina acrílica que copiou uma raiz natural com proporções dentro da média. O compósito foi escolhido pelas propriedades mecânicas mais próximas das propriedades mecânicas da dentina. Todas as raízes e as réplicas foram submetidas a forças compressivas de uma ponta metálica cônica (simulação do pino intrarradicular), até a fratura. A velocidade de avanço da ponta foi de 5mm/min. Na segunda etapa, foram confeccionadas 30 réplicas, divididas em 3 grupos (n=10). Todas foram restauradas com pinos metálicos fundidos e coroas metálicas. No grupo FZ os pinos foram cimentados com fosfato de zinco; no grupo CRD foi aplicada uma camada de vaselina sólida no conduto radicular e os pinos foram cimentados com cimento resinoso dual; no grupo CRC foi feita aplicação de um agente de união no conduto radicular e os pinos foram cimentados com cimento resinoso dual. Os espécimes foram submetidas a ciclagem mecânica de 130.000 ciclos sob pressão de 5bar. Duas raízes de cada grupo foram utilizadas para testar os parâmetros do ensaio de resistência à fratura. Em seguida, as outras raízes (n=8) foram submetidas ao teste de resistência sob forças compressivas até a ruptura. A carga foi aplicada com inclinação de 20º e velocidade de 5mm/min. RESULTADOS: Na comparação entre a resistência das raízes naturais e artificiais à penetração de pino no conduto radicular, houve diferença estatística entre os dois grupos. As raízes artificiais apresentam maior resistência à fratura (115,4MPa) do que as raízes naturais (75,4MPa). O coeficiente de variação das réplicas (21%) é menor que o das raízes naturais (36,3%), o que indica uma menor variabilidade da amostra das réplicas. Mesmo com valores diferentes, há semelhança na direção do traço de fratura e no local onde ocorrem. Esse resultado indica que a concentração de tensões e a propagação da fratura é semelhante em dentina e compósito. Quanto às réplicas restauradas com pinos, não houve diferença estatística entre os grupos. CONCLUSÃO: As raízes artificiais quando comparadas as raízes naturais, apresentam maior resistência à fratura, menor variação dos resultados individuais em torno da média e modo de fratura semelhante às raízes naturais. Desta maneira, é viável a utilização das réplicas nos estudos sobre mecânica da fratura. / OBJECTIVE: The restoration of endodontically treated teeth is a challenge for dentistry. The fracture of the remaining root is common in this treatment. There are three methods used to study fractures: a finite element analysis, using the natural teeth and those who use artificial teeth. The use of natural teeth has some disadvantages, such as anatomical variations and a history of exposure to stresses (which increase the variability of the sample and the findings difficult), beyond the limited availability of specimens. This study aims to evaluate the feasibility of using composite for the construction of artificial roots and application of these replicas in studies of these fractures. METHODS: In the first stage were used 50 single-rooted roots of 2nd premolar and 50 replicas. The natural roots were selected for having similar anatomical features. The replicas were made from an acrylic resin such that a natural root copied with ratios in the average. The composite was selected by the mechanical properties closer to the mechanical properties of the dentin. All the roots and the replicas were subjected to compressive forces of a conical metal tip (simulation post) until failure. The feed rate was tip of 5mm/min. In the second step, 30 replicas were prepared, divided into 3 groups (n = 10). All were filled with molten metal pins and metal crowns. In group A the posts were cemented with zinc phosphate, group B was applied to a solid layer of vaseline in the root canal and the posts were cemented with dual resin cement, in group C was made applying a bonding agent in the root canal and the posts were cemented with dual resin cement. The specimens were subjected to mechanical loading of 130,000 cycles under a pressure of 5bar. Two roots from each group were used to test the parameters of fracture toughness test. Then the other root (n = 8) were subjected to endurance test under compressive forces until failure. The load was applied with an inclination of 20° and speed 5mm/min. RESULTS: Comparing the resistance of natural and artificial root penetration of the pin in the root canal, was no statistical difference between the two groups. The artificial roots showed higher fracture strength (115.4 MPa) than the natural roots (75.4 MPa). The coefficient of variation of the replicas (21%) is less than the natural root (36.3%), indicating a lower variability of the replicas of the sample. Even with different values, there are similarities in the direction of the fracture site and where they occur. This result indicates that the stress concentration and fracture propagation is similar in dentin and composite. As for replicas restored with posts, no statistical difference between groups was found. CONCLUSION: The artificial roots showed greater resistance to fracture when compared to natural roots, less variation of individual results around the mean and mode of fracture similar to the natural roots. Thus, it is feasible to use in studies of replicas of fracture mechanics.
15

Estudo in vitro da perfuração radicular por diferentes diâmetros de mini-implantes / In vitro study of root perforation by different mini-implant diameters

Roberto Bombonatti 07 November 2014 (has links)
Este trabalho teve como objetivo avaliar o torque e a carga axial de inserção e a severidade das lesões radiculares em dentes humanos decorrentes da utilização de diferentes diâmetros de mini-implantes com finalidade ortodôntica. Sessenta pré-molares extraídos foram inclusos em osso artificial e divididos em 3 grupos, correspondentes a 3 diferentes diâmetros de mini-implante (1,4mm, 1,6mm e 1,8mm). Em cada raiz dentária foram inseridos manualmente 2 mini-implantes autoperfurantes utilizando dois métodos de inserção (com e sem perfuração prévia inicial com fresa) e em duas alturas (apical e cervical). Quinze mini-implantes foram inseridos apenas em osso artificial como parâmetro de comparação. Foram quantificados o torque e a carga axial de inserção através de um torquímetro axial digital e uma célula de carga respectivamente. Os dentes foram, então, escaneados e analisados através de microtomografia computadorizada (Micro-CT) a fim de se observar as severidades das lesões radiculares provocadas pelos mini-implantes. Os dados referentes ao torque e à carga axial dos mini-implantes inseridos em pré-molares foram submetidos à análise de variância (ANOVA) a três critérios, sendo aplicados posteriormente testes de Tukey para comparação entre os grupos. A diferença dos torques e das cargas axiais entre os mini-implantes inseridos no osso artificial e nas raízes dentárias foi estimada por testes t. Foram aplicados também testes de Qui-Quadrado para avaliar as severidades das lesões radiculares. Tanto os torques como as cargas axiais de inserção dos mini-implantes inseridos em raízes de dentes humanos apresentaram diferenças estatisticamente significantes entre os diferentes diâmetros avaliados, porém sem um padrão definido. Os miniimplantes inseridos nas raízes apresentaram valores maiores estatisticamente significantes do que os inseridos em osso artificial somente em relação à carga axial. As lesões radiculares de dentes humanos decorrentes dos mini-implantes se tornaram mais severas estatisticamente com a perfuração prévia inicial ao procedimento de inserção. / The aim of this study was to evaluate placement torque, axial placement load and severity of root lesions in human teeth caused by different diameters of orthodontic mini-implants. Sixty extracted premolars were included in artificial bone and divided into three groups according to different mini-implant diameters (1.4mm, 1.6mm and 1.8mm). Two self-drilling mini-implants were manually inserted into each root using two placement methods (with and without initial pre-drilling) in the apical and cervical regions. Fifteen mini-implants were inserted into artificial bone as a comparison parameter. Placement torque and axial placement load were quantified by a digital torquimeter and a load cell, respectively. The teeth were scanned and analyzed with microcomputed tomography (Micro-CT) to observe the severity of root lesions caused by the mini-implants. The torque and the axial load of mini-implants inserted into premolars were analyzed by 3-way analysis of variance (ANOVA), followed by Tukey tests. Differences in the torques and axial loads between the mini-implants inserted in dental roots and artificial bone were compared with t tests. Chi-square tests were applied to assess the severity of root lesions. The placement torques and the axial placement loads of mini-implants inserted into human dental roots showed significant differences between the different diameters evaluated, but with no standardized effect. Mini-implants inserted into the roots showed significantly higher axial placement load values than those inserted into artificial bone. The root lesions of human teeth caused by mini-implants became statistically more severe with initial pre-drilling.
16

Estudo in vitro da perfuração radicular por diferentes diâmetros de mini-implantes / In vitro study of root perforation by different mini-implant diameters

Bombonatti, Roberto 07 November 2014 (has links)
Este trabalho teve como objetivo avaliar o torque e a carga axial de inserção e a severidade das lesões radiculares em dentes humanos decorrentes da utilização de diferentes diâmetros de mini-implantes com finalidade ortodôntica. Sessenta pré-molares extraídos foram inclusos em osso artificial e divididos em 3 grupos, correspondentes a 3 diferentes diâmetros de mini-implante (1,4mm, 1,6mm e 1,8mm). Em cada raiz dentária foram inseridos manualmente 2 mini-implantes autoperfurantes utilizando dois métodos de inserção (com e sem perfuração prévia inicial com fresa) e em duas alturas (apical e cervical). Quinze mini-implantes foram inseridos apenas em osso artificial como parâmetro de comparação. Foram quantificados o torque e a carga axial de inserção através de um torquímetro axial digital e uma célula de carga respectivamente. Os dentes foram, então, escaneados e analisados através de microtomografia computadorizada (Micro-CT) a fim de se observar as severidades das lesões radiculares provocadas pelos mini-implantes. Os dados referentes ao torque e à carga axial dos mini-implantes inseridos em pré-molares foram submetidos à análise de variância (ANOVA) a três critérios, sendo aplicados posteriormente testes de Tukey para comparação entre os grupos. A diferença dos torques e das cargas axiais entre os mini-implantes inseridos no osso artificial e nas raízes dentárias foi estimada por testes t. Foram aplicados também testes de Qui-Quadrado para avaliar as severidades das lesões radiculares. Tanto os torques como as cargas axiais de inserção dos mini-implantes inseridos em raízes de dentes humanos apresentaram diferenças estatisticamente significantes entre os diferentes diâmetros avaliados, porém sem um padrão definido. Os miniimplantes inseridos nas raízes apresentaram valores maiores estatisticamente significantes do que os inseridos em osso artificial somente em relação à carga axial. As lesões radiculares de dentes humanos decorrentes dos mini-implantes se tornaram mais severas estatisticamente com a perfuração prévia inicial ao procedimento de inserção. / The aim of this study was to evaluate placement torque, axial placement load and severity of root lesions in human teeth caused by different diameters of orthodontic mini-implants. Sixty extracted premolars were included in artificial bone and divided into three groups according to different mini-implant diameters (1.4mm, 1.6mm and 1.8mm). Two self-drilling mini-implants were manually inserted into each root using two placement methods (with and without initial pre-drilling) in the apical and cervical regions. Fifteen mini-implants were inserted into artificial bone as a comparison parameter. Placement torque and axial placement load were quantified by a digital torquimeter and a load cell, respectively. The teeth were scanned and analyzed with microcomputed tomography (Micro-CT) to observe the severity of root lesions caused by the mini-implants. The torque and the axial load of mini-implants inserted into premolars were analyzed by 3-way analysis of variance (ANOVA), followed by Tukey tests. Differences in the torques and axial loads between the mini-implants inserted in dental roots and artificial bone were compared with t tests. Chi-square tests were applied to assess the severity of root lesions. The placement torques and the axial placement loads of mini-implants inserted into human dental roots showed significant differences between the different diameters evaluated, but with no standardized effect. Mini-implants inserted into the roots showed significantly higher axial placement load values than those inserted into artificial bone. The root lesions of human teeth caused by mini-implants became statistically more severe with initial pre-drilling.
17

Avaliação da relação entre as raízes dos dentes posteriores e o assoalho do seio maxilar em pessoas sem e com fissura labiopalatina

Otávio Pagin 10 August 2015 (has links)
O seio maxilar apresenta formato distinto e volume variável entre as pessoas e seu assoalho pode ser encontrado em íntimo contato com as raízes dos dentes posteriores, podendo haver protrusão dessas raízes em seu interior. Tal proximidade é de grande relevância frente aos casos de comunicação bucossinusal em potencial ou pela possibilidade de desenvolvimento de um quadro infeccioso de origem odontogênica, em que esse pode vir a se estender para o interior do seio maxilar. Existe uma ausência de trabalhos na literatura acerca da relação estabelecida entre dentes posteriores e o seio maxilar em pessoas com fissura labiopalatina. O objetivo do presente estudo foi identificar e comparar a relação entre o assoalho do seio maxilar e os ápices radiculares dos dentes posteriores em imagens de tomografia computadorizada de feixe cônico em pessoas sem fissura labiopalatina e com fissura transforame incisivo unilateral e bilateral. Foram avaliados 100 indivíduos sem anomalias craniofaciais e 112 com fissura transforame incisivo unilateral ou bilateral, não sindrômicos, utilizando o programa i-CAT® Vision, onde a relação estabelecida pelas estruturas foi convencionada sendo, tipo 0 ou ausência de contato entre as estruturas, tipo 1 ou relação de íntimo contato entre as estruturas sem protrusão radicular no interior do seio maxilar e tipo 2 ou relação de íntimo contato entre as estruturas com protrusão radicular no interior do seio maxilar. Foi utilizado o teste do qui-quadrado para comparar os achados entre os grupos estudados, considerando valor estatisticamente significante quando p&#x2264; 0,05. Foi avaliada a relação do assoalho do seio maxilar com 1679 dentes, totalizando 3664 raízes onde 1883 (51,3%) foram classificadas como tipo 0, 1456 (39,7%) tipo 1 e 325 (8,8%) do tipo 2. Houve diferença estatisticamente significante para a raiz palatina do dente 18 entre os grupos com fissura unilateral e bilateral (p = 0,011), para a raiz mesiovestibular do dente 18 entre os grupos sem fissura e fissura bilateral (p = 0,046), bem como entre os grupos com fissura unilateral e bilateral (p = 0,016) e para a raiz vestibular do dente 24 entre os grupos sem fissura e com fissura bilateral (p = 0,001). Pessoas com fissura transforame incisivo unilateral e bilateral tendem a apresentar maior ocorrência da raiz vestibular do dente 24 (p = 0,027) e mesiovestibular do dente 16 (p = 0,047) em proximidade com o seio maxilar quando comparadas às pessoas sem fissura. Pessoas com fissura transforame incisivo bilateral tendem a apresentar uma maior ocorrência de proximidade com o seio maxilar das raízes vestibular do dente 24 (p = 0,001) e mesiovestibular do dente 18 (p = 0,046) quando comparados às pessoas sem fissura. A avaliação das raízes dos dentes posteriores por meio de imagens de tomografia computadorizada de feixe cônico e sua relação com o seio maxilar oferecem detalhamento e precisão, contribuindo assim para a elaboração de um diagnóstico e plano de tratamento que visam minimizar os riscos de acidentes e complicações. / The maxillary sinus has a remarkable feature and a variable volume among people where the inferior wall may be found in an intimate relation with the posterior teeth roots protruding or not inside the antrum. This proximity is of great relevance considering a potential oroantral communication or the spreading of an odontogenic infection into the maxillary sinus. There is a lack of evidence into the literature regarding the relationship between posterior teeth roots and the maxillary sinus in non-syndromic complete cleft lip and palate patients. This study aimed to evaluate and compare cone beam computed tomography images regarding the relationship between the posterior teeth roots and the maxillary sinus floor in non-cleft lip and palate patients and non-syndromic complete unilateral and bilateral cleft lip and palate patients. Images were interpreted using the i-CAT® Vision software including 100 noncleft patients and 112 presenting non-syndromic complete unilateral and bilateral cleft lip and palate. The relationship between teeth roots and the maxillary sinus floor was established as type 0 or no contact between these structures, type 1 or close contact without root protrusion into the sinus and type 2 or close contact with root protrusion into the sinus. The chi-square test, considering a statistically significant value where p&#x2264;0,05, was used to compare data between different groups. The sample included 1679 teeth and 3664 roots where 1883 (51,3%) were classified as type 0, 1456 (39,7%) as type 1 and 325 (8,8%) as type 2. There were statistically significant differences for tooth 18 palatine root between both complete cleft lip and palate groups (p = 0,011), for tooth 18 mesiobuccal root between noncleft and the bilateral groups (p = 0,046) and between both complete cleft lip and palate groups (p = 0,016) and for tooth 24 buccal root between non-cleft and the bilateral group (p = 0,001). Complete unilateral and bilateral cleft lip and palate patients presented a higher occurrence when compared with the non-cleft group of the tooth 24 buccal root (p = 0,027) and the tooth 16 mesiobuccal root (p = 0,047) in proximity with the maxillary sinus. Complete bilateral cleft lip and palate patients had a higher occurrence when compared with the non-cleft group of the tooth 24 buccal root (p = 0,001) and the tooth 18 mesiobuccal root (p = 0,046) in proximity with the sinus floor. The posterior teeth roots relationship with the maxillary sinus floor is better depicted and accurate by cone beam computed tomography images that may collaborated for a diagnosis and treatment planning that reduces the risks.
18

Viabilidade da substituição de raízes de dentes humanos por raízes construídas em compósito para estudos de mecânica da fratura / Viability of replacing the roots of human teeth by roots made of composite for the study of fracture mechanics

Camila Oliveira Moraes Espósito 27 April 2012 (has links)
OBJETIVO: A restauração de dentes tratados endodonticamente é um desafio para a Odontologia. A fratura do remanescente radicular é comum neste tratamento. São três os métodos utilizados para estudar as fraturas: a análise por elementos finitos, os que utilizam dentes naturais e aqueles que utilizam dentes artificiais. O uso de dentes naturais apresenta alguns inconvenientes, como as variações anatômicas e de histórico de exposição a esforços (que aumentam a variabilidade da amostra e dificultam as conclusões), além da pequena disponibilidade de espécimes. Este estudo propõe-se avaliar a viabilidade de usar compósito para a construção de raízes artificiais e a aplicação dessas réplicas em estudos sobre a essas fraturas. MÉTODOS: Na primeira etapa foram utilizadas 50 raízes unirradiculares de 2º pré-molar superior e 50 réplicas. As raízes naturais foram selecionadas por terem características anatômicas semelhantes. As réplicas foram confeccionadas a partir de um molde de resina acrílica que copiou uma raiz natural com proporções dentro da média. O compósito foi escolhido pelas propriedades mecânicas mais próximas das propriedades mecânicas da dentina. Todas as raízes e as réplicas foram submetidas a forças compressivas de uma ponta metálica cônica (simulação do pino intrarradicular), até a fratura. A velocidade de avanço da ponta foi de 5mm/min. Na segunda etapa, foram confeccionadas 30 réplicas, divididas em 3 grupos (n=10). Todas foram restauradas com pinos metálicos fundidos e coroas metálicas. No grupo FZ os pinos foram cimentados com fosfato de zinco; no grupo CRD foi aplicada uma camada de vaselina sólida no conduto radicular e os pinos foram cimentados com cimento resinoso dual; no grupo CRC foi feita aplicação de um agente de união no conduto radicular e os pinos foram cimentados com cimento resinoso dual. Os espécimes foram submetidas a ciclagem mecânica de 130.000 ciclos sob pressão de 5bar. Duas raízes de cada grupo foram utilizadas para testar os parâmetros do ensaio de resistência à fratura. Em seguida, as outras raízes (n=8) foram submetidas ao teste de resistência sob forças compressivas até a ruptura. A carga foi aplicada com inclinação de 20º e velocidade de 5mm/min. RESULTADOS: Na comparação entre a resistência das raízes naturais e artificiais à penetração de pino no conduto radicular, houve diferença estatística entre os dois grupos. As raízes artificiais apresentam maior resistência à fratura (115,4MPa) do que as raízes naturais (75,4MPa). O coeficiente de variação das réplicas (21%) é menor que o das raízes naturais (36,3%), o que indica uma menor variabilidade da amostra das réplicas. Mesmo com valores diferentes, há semelhança na direção do traço de fratura e no local onde ocorrem. Esse resultado indica que a concentração de tensões e a propagação da fratura é semelhante em dentina e compósito. Quanto às réplicas restauradas com pinos, não houve diferença estatística entre os grupos. CONCLUSÃO: As raízes artificiais quando comparadas as raízes naturais, apresentam maior resistência à fratura, menor variação dos resultados individuais em torno da média e modo de fratura semelhante às raízes naturais. Desta maneira, é viável a utilização das réplicas nos estudos sobre mecânica da fratura. / OBJECTIVE: The restoration of endodontically treated teeth is a challenge for dentistry. The fracture of the remaining root is common in this treatment. There are three methods used to study fractures: a finite element analysis, using the natural teeth and those who use artificial teeth. The use of natural teeth has some disadvantages, such as anatomical variations and a history of exposure to stresses (which increase the variability of the sample and the findings difficult), beyond the limited availability of specimens. This study aims to evaluate the feasibility of using composite for the construction of artificial roots and application of these replicas in studies of these fractures. METHODS: In the first stage were used 50 single-rooted roots of 2nd premolar and 50 replicas. The natural roots were selected for having similar anatomical features. The replicas were made from an acrylic resin such that a natural root copied with ratios in the average. The composite was selected by the mechanical properties closer to the mechanical properties of the dentin. All the roots and the replicas were subjected to compressive forces of a conical metal tip (simulation post) until failure. The feed rate was tip of 5mm/min. In the second step, 30 replicas were prepared, divided into 3 groups (n = 10). All were filled with molten metal pins and metal crowns. In group A the posts were cemented with zinc phosphate, group B was applied to a solid layer of vaseline in the root canal and the posts were cemented with dual resin cement, in group C was made applying a bonding agent in the root canal and the posts were cemented with dual resin cement. The specimens were subjected to mechanical loading of 130,000 cycles under a pressure of 5bar. Two roots from each group were used to test the parameters of fracture toughness test. Then the other root (n = 8) were subjected to endurance test under compressive forces until failure. The load was applied with an inclination of 20° and speed 5mm/min. RESULTS: Comparing the resistance of natural and artificial root penetration of the pin in the root canal, was no statistical difference between the two groups. The artificial roots showed higher fracture strength (115.4 MPa) than the natural roots (75.4 MPa). The coefficient of variation of the replicas (21%) is less than the natural root (36.3%), indicating a lower variability of the replicas of the sample. Even with different values, there are similarities in the direction of the fracture site and where they occur. This result indicates that the stress concentration and fracture propagation is similar in dentin and composite. As for replicas restored with posts, no statistical difference between groups was found. CONCLUSION: The artificial roots showed greater resistance to fracture when compared to natural roots, less variation of individual results around the mean and mode of fracture similar to the natural roots. Thus, it is feasible to use in studies of replicas of fracture mechanics.
19

Atividade proteolítica e resistência da união cimento resinoso-dentina radicular produzida na presença de agentes promotores de ligações cruzadas / Proteolytic activity and bond strength of the resin cement-root dentin interface produced in the presence of cross-linkers

Alonso, Juliana Rosa Luiz [UNESP] 06 April 2016 (has links)
Submitted by JULIANA ROSA LUIZ ALONSO null (ju29alonso@hotmail.com) on 2016-05-02T19:21:59Z No. of bitstreams: 1 Versão Final_Dissertação_Juliana Alonso.pdf: 3284684 bytes, checksum: 5cf89df8ddd554ca35ba036626ed5bdb (MD5) / Approved for entry into archive by Felipe Augusto Arakaki (arakaki@reitoria.unesp.br) on 2016-05-04T18:51:25Z (GMT) No. of bitstreams: 1 alonso_jrl_me_arafo.pdf: 3284684 bytes, checksum: 5cf89df8ddd554ca35ba036626ed5bdb (MD5) / Made available in DSpace on 2016-05-04T18:51:25Z (GMT). No. of bitstreams: 1 alonso_jrl_me_arafo.pdf: 3284684 bytes, checksum: 5cf89df8ddd554ca35ba036626ed5bdb (MD5) Previous issue date: 2016-04-06 / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / A estabilidade da união resina-dentina pode ser melhorada pelo uso de agentes promotores de ligações cruzadas (cross-linkers). Todavia, existe pouca informação quanto ao desempenho desses agentes em dentina radicular. Portanto, o objetivo do presente estudo foi avaliar o efeito de três cross-linkers na atividade proteolítica e na resistência da união cimento resinoso-dentina radicular. Raízes unirradiculares foram obtidas de pré-molares humanos (n=48). Após tratamento endodôntico, essas raízes foram distribuídas em 4 grupos (n=12): água deionizada (controle), carbodiimida (EDC) 0,5 mol/L, proantocianidina (PA) 5% ou glutaraldeído (GD) 5%. Decorridas 24h do tratamento com esses agentes e da cimentação de pinos de fibra de vidro com cimento resinoso, as raízes foram seccionadas transversalmente para a obtenção de espécimes com 1 mm de espessura, das regiões cervical, média e apical. Nove raízes por grupo foram utilizadas para o ensaio mecânico de extrusão e três para determinação da atividade proteolítica dentinária, por meio de zimografia in situ. Os dados de resistência de união (RU) foram submetidos aos testes de ANOVA e Tukey e a existência de associação entre o tipo de fratura e as variáveis independentes do estudo foi determinada pelo teste de qui-quadrado (2) (=0,05). Nenhum dos cross-linkers afetou a RU imediata. GD aumentou esses valores significativamente em comparação à PA, mas não ao controle. Houve redução significante da RU do terço cervical para o apical, exceto para o grupo PA. Aumento na porcentagem de fraturas adesivas entre o pino de fibra de vidro e o cimento resinoso foi observado para os grupos EDC e GD, em relação ao grupo controle, enquanto, para PA, houve aumento de fraturas adesivas entre o cimento resinoso e a dentina. Foi observada grande atividade gelatinolítica no grupo controle, a qual foi reduzida por todos os cross-linkers . Em conclusão, além de não interferirem negativamente na RU imediata, os cross-linkers reduziram a atividade proteolítica na camada híbrida da união cimento resinoso-dentina radicular. / The resin-dentin bond stability can be improved by the use of cross-linkers. However, only scarce information is available as to the performance of these agents on root dentin. Therefore, the aim of this study was to evaluate the effect of three cross-linkers on the proteolytic activity of root dentin and on the bond strength of resin-based cement-root dentin interfaces. Single canal roots were obtained from human premolars (n=48). After endodontic treatment, they were randomly divided into four groups: deionized water (control), 0.5 mol/L carbodiimide (EDC), 5% proanthocyanidin (PA) or 5% glutaraldehyde (GD). After 24h from dentin treatment with the cross-linkers and the cementation of a fiber post with a resin-based cement, the roots were transversally sectioned to obtain 1 mm-thick specimens, from the cervical, mid and apical areas. Nine roots per group were used for the push-out test and three for determining the proteolytic activity of the root dentin by in situ zymography. Bond strength data were submitted to ANOVA and Tukey tests and the existence of an association between the type of fracture and the independent variables of the study was determined by chi-square test (=0.05). None of the cross-linkers affected the bond strength. GD increased bond strength compared to PA, but both were similar to the control. Significant reduction in bond strength was observed between the cervical and the apical root thirds. Increase in the percentage of adhesive fractures between the glass fiber post and resin cement was observed for EDC and GD groups, in comparison with the control group, while for PA, an increase of adhesive fractures between the resin cement and dentin was observed. Intense gelatinolytic activity was seen in the control group which was remarkably reduced in the cross-linker-treated groups. In conclusion, besides not interfering with bond strength, the cross-linkers reduced the proteolytic activity in the hybrid layers of the resin cement-root dentin bond. / FAPESP: 2014/10183-8

Page generated in 0.1117 seconds