• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 18
  • 5
  • Tagged with
  • 23
  • 23
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Diseño de un detector de rayos X y rayos Gamma para aplicaciones de radiografía industrial

Salcedo Soto, Carlos Hernán 13 May 2014 (has links)
La radiación ionizante se encuentra en nuestro mundo de forma natural y es una herramienta tanto beneficiosa como dañina para el ser humano. El objetivo final de esta tesis es evadir los efectos dañinos, en específico, de la radiación X y gamma. Durante este asunto de estudio se muestra el proceso detallado del diseño de un equipo de detección de rayos X y rayos gamma utilizando como pieza principal un diodo PIN de silicio modelo S3590-08, del fabricante Hamamatsu Photonics, capaz de sensar la intensidad de los rayos gamma y los rayos X a distintas energías. El equipo es capaz de procesar los datos gracias a un microcontrolador Atmega8 de la compañía Atmel, y mostrar al usuario la dosis de radiación a la que está expuesto en tiempo real a través de una pantalla de cristal líquido. También le advierte al operario si ha superado un valor seguro a través de mensajes y de dos alarmas, una visual y la otra sonora. Todo el diseño es validado en base a simulaciones de software que emulan el comportamiento, de forma aproximada, de la electrónica utilizada en la tesis. Además, se añade un protocolo de pruebas frente a radiación X para una futura etapa de implementación, calibración y uso final del equipo en el Laboratorio de Materiales de la especialidad de Ingeniería Mecánica.
22

Algoritmo de reconstrucción analítico para el escáner basado en cristales monolíticos MINDView

Sánchez Góez, Sebastián 17 January 2021 (has links)
[ES] La tomografía por emisión de positrones (PET, del inglés Positron Emission Tomography) es una técnica de medicina nuclear en la que se genera una imagen a partir de la detección de rayos gamma en coincidencia. Estos rayos son producidos dentro de un paciente al que se le inyecta una radiotrazador emisor de positrones, los cuales se aniquilan con electrones del medio circundante. El proceso de adquisición de eventos de interacción, tiene como unidad central el detector del escáner PET, el cual se compone a su vez de un cristal de centelleo, encargado de transformar los rayos gamma incidentes en fotones ópticos dentro del cristal. La finalidad es entonces, determinar las coordenadas de impacto dentro del cristal de centelleo con la mayor precisión posible, para que, a partir de dichos puntos, se pueda reconstruir una imagen. A lo largo de la historia, los detectores basados en cristales pixelados han representado la elección por excelencia para la la fabricación de escáneres PET. En está tesis se evalúa el impacto en la resolución espacial del escáner PET MINDView, desarrollado dentro del séptimo programa Marco de la Unión Europea No 603002, el cual se basa en el uso de cristales monolíticos. El uso de cristales monolíticos, facilita la determinación de la profundidad de interacción (DOI - del inglés Depth Of Interaction) de los rayos gamma incidentes, aumenta la precisión en las coordenadas de impacto determinadas, y disminuye el error de paralaje que se induce en cristales pixelados, debido a la dificultad para determinar la DOI. En esta tesis, hemos logrado dos objetivos principales relacionados con la medición de la resolución espacial del escáner MINDView: la adaptación del un algoritmo de STIR de Retroproyección Filtrada en 3D (FBP3DRP - del inglés Filtered BackProjection 3D Reproyected) a un escáner basado en cristales monolíticos y la implementación de un algoritmo de Retroproyección y filtrado a posteriori (BPF - BackProjection then Filtered). Respecto a la adaptación del algoritmo FBP, las resoluciones espaciales obtenidas varían en los intervalos [2 mm, 3,4 mm], [2,3 mm, 3,3 mm] y [2,2 mm, 2,3 mm] para las direcciones radial, tangencial y axial, respectivamente, en el primer prototipo del escáner MINDView dedicado a cerebro. Por otra parte, en la implementación del algoritmo de tipo BPF, se realizó una adquisición de un maniquí de derenzo y se comparó la resolución obtenida con el algoritmo de FBP y una implementación del algoritmo de subconjuntos ordenados en modo lista (LMOS - del inglés List Mode Ordered Subset). Mediante el algoritmo de tipo BPF se obtuvieron valores pico-valle de 2.4 a lo largo de los cilindros del maniquí de 1.6 mm de diámetro, en contraste con las medidas obtenidas de 1.34 y 1.44 para los algoritmos de FBP3DRP y LMOS, respectivamente. Lo anterior se traduce en que, mediante el algoritmo de tipo BPF, se logra mejorar la resolución para obtenerse un valor promedio 1.6 mm. / [CAT] La tomografia per emissió de positrons és una tècnica de medicina nuclear en la qual es genera una imatge a partir de la detecció de raigs gamma en coincidència. Aquests raigs són produïts dins d'un pacient a què se li injecta una radiotraçador emissor de positrons, els quals s'aniquilen amb electrons de l'medi circumdant. El procés de adquición d'esdeveniments d'interacció, té com a unitat central el detector de l'escàner PET, el qual es compon al seu torn d'un vidre de centelleig, encarregat de transformar els raigs gamma incidents en fotons òptics dins el vidre. La finalitat és llavors, determinar les coordenades d'impacte dins el vidre de centelleig amb la major precisió possible, perquè, a partir d'aquests punts, es pugui reconstruir una imatge. Al llarg de la història, els detectors basats en cristalls pixelats han representat l'elecció per excellència per a la la fabricació d'escàners PET. En aquesta tesi s'avalua l'impacte en la resolució espacial de l'escàner PET MINDView, desenvolupat dins el setè programa Marc de la Unió Europea No 603.002, el qual es basa en l'ús de vidres monolítics. L'ús de vidres monolítics, facilita la determinació de la profunditat d'interacció dels raigs gamma incidents, augmenta la precisió en les coordenades d'impacte determinades, i disminueix l'error de parallaxi que s'indueix en cristalls pixelats, a causa de la dificultat per determinar la DOI. En aquesta tesi, hem aconseguit dos objectius principals relacionats amb el mesurament de la resolució espacial de l'escàner MINDView: l'adaptació de l'un algoritme de STIR de Retroprojecció Filtrada en 3D a un escàner basat en cristalls monolítics i la implementació d'un algoritme de Retroprojecció i filtrat a posteriori. Pel que fa a l'adaptació de l'algoritme FBP3DRP, les resolucions espacials obtingudes varien en els intervals [2 mm, 3,4 mm], [2,3 mm, 3,3 mm] i [2,2 mm, 2,3 mm] per les direccions radial, tangencial i axial, respectivament, en el primer prototip de l'escàner MINDView dedicat a cervell. D'altra banda, en la implementació de l'algoritme de tipus BPF, es va realitzar una adquisició d'un maniquí de derenzo i es va comparar la resolució obtinguda amb l'algorisme de FBP3DRP i una implementació de l'algoritme de subconjunts ordenats en mode llista (LMOS - de l'anglès List Mode Ordered Subset). Mitjançant l'algoritme de tipus BPF es van obtenir valors pic-vall de 2.4 al llarg dels cilindres de l'maniquí de 1.6 mm de diàmetre, en contrast amb les mesures obtingudes de 1.34 i 1.44 per als algoritmes de FBP3DRP i LMOS, respectivament. L'anterior es tradueix en que, mitjançant l'algoritme de tipus BPF, s'aconsegueix millorar la resolució per obtenir-se un valor mitjà 1.6 mm. / [EN] Positron Emission Tomography (PET) is a medical imaging technique, in which an image is generated from the detection of gamma rays in coincidence. These rays are produced within a patient, who is injected with a positron emmiter radiotracer, from which positrons are annihilated with electrons in the media. The event acquisition process is focused on the scanner detector. The detector is in turn composed of a scintillation crystal, which transform the incident ray gamma into optical photons within the crystal. The purpose is then to determine the impact coordinates within the scintillation crystal with the greatest possible precision, so that, from these points, an image can be reconstructed. Throughout history, detectors based on pixelated crystals have represented the quintessential choice for PET scanners manufacture. This thesis evaluates the impact on the spatial resolution of the MINDView PET scanner, developed in the seventh Framework program of the European Union No. 603002, which detectors are based on monolithic crystals. The use of monolithic crystals facilitates the determination of the depth of interaction (DOI - Depth Of Interaction) of the incident gamma rays, increases the precision in the determined impact coordinates, and reduces the parallax error induces in pixelated crystals, due to the difficulties in determining DOI. In this thesis, we have achieved two main goals related to the measurement of the spatial resolution of the MINDView PET scanner: the adaptation of an STIR algorithm for Filtered BackProjection 3D Reproyected (FBP3DRP) to a scanner based on monolithic crystals, and the implementation of a BackProjection then Filtered algorithm (BPF). Regarding the FBP algorithm adaptation, we achieved resolutions ranging in the intervals [2 mm, 3.4 mm], [2.3 mm, 3.3 mm] and [2.2 mm, 2.3 mm] for the radial, tangential and axial directions, respectively. On the an acquisition of a derenzo phantom was performed to measure the spacial resolution, which was obtained using three reconstruction algorithms: the BPF-type algorithm, the FBP3DRP algorithm and an implementation of the list-mode ordered subsets algorithm (LMOS). Regarding the BPF-type algorithm, a peak-to-valley value of 2.4 were obtain along rod of 1.6 mm, in contrast to the measurements of 1.34 and 1.44 obtained for the FBP3DRP and LMOS algorithms, respectively. This means that, by means of the BPF-type algorithm, it is possible to improve the resolution to obtain an average value of 1.6 mm. / Sánchez Góez, S. (2020). Algoritmo de reconstrucción analítico para el escáner basado en cristales monolíticos MINDView [Tesis doctoral]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/159259 / TESIS
23

The keV-TeV connection in gamma-ray binaries

Zabalza de Torres, Victor 13 May 2011 (has links)
Gamma-ray binaries are systems that comprise a young, massive star and a compact object that can be either a young pulsar or a black hole. They emit radiation from radio up to tens of TeV and show flux variability along the whole electromagnetic spectrum. For three of the four detected gamma-ray binaries, the nature of the compact object is unknown. In this thesis we present a study of gamma-ray binaries through three approaches that involve the simultaneous study of these sources in X-rays and very high energy (VHE) gamma-rays. We present the discovery of correlated X-ray and VHE gamma-ray emission from LS I +61 303. The correlations indicates that the emission from these two bands could be originated in the same parent particle population, and we explore this idea through the calculation of a radiative model. This model allows us to significantly constrain the physical properties of the non-thermal emitter in LS I +61 303. For those systems where the compact object is a young pulsar, the interaction between the stellar and pulsar winds will give rise to strong shocks. The shocked pulsar wind is the candidate location for non-thermal emission from these systems. The shocked stellar wind should give rise to a thermal X-ray spectrum, but no such features have been detected in the X-ray spectrum of gamma-ray binaries. We present a model of the thermal emission of the shocked stellar wind and use it to constrain the pulsar properties. We have applied this method to two X-ray observations of LS 5039 and have successfully constrained the pulsar spin-down luminosity. Finally, we present a search for VHE emission from Scorpius X-1 through a simultaneous X-ray and VHE gamma-ray campaign. The X-ray observations allowed us to select black-hole states where non-thermal X-ray emission has been detected. We did not find significant VHE emission in any of the black hole states, but the upper limits derived will prove useful in future modelling of the non-thermal emitter in the source. / Les binàries de raigs gamma són sistemes binaries formats per una estrella jove i massiva i un objecte compacte, que pot ser un púlsar jove o un forat negre, que emeten radiació fins a desenes de TeV i mostren variabilitat orbital en totes les bandes d'emissió, des de radio fins a raigs gamma. En el cas de tres de les quatre binàries de raigs gamma detectades avui dia, se'n desconeix la natura de l'objecte compacte. En aquesta tesi presentem un estudi de les binàries de raigs gamma mitjançant tres treballs complementaris que involucren l'estudi simultani d'aquestes fonts en raigs X i raigs gamma de molt alta energia. En primer lloc presentem el descobriment d'emissió en raigs X i raigs gamma de molt alta energia correlades en el temps al sistema LS I +61 303. Aquesta correlació ens indica que l'emissió en les dues bandes pot provenir d'una única població d'electrons, i ho confirmem mitjançant la realització d'un model teòric de radiació que ens permet restringir significativament les propietats físiques de l'emissor no tèrmic de la font. En cas que la font energètica dels sistemes sigui un púlsar, la interacció entre els vents de l'estrella i el púlsar dona lloc a una regió d'interacció on el vent xocat del púlsar accelera partícules i emet des de radio fins a raigs gamma. A l'espectre de raigs X, però, no es detecta l'emissió tèrmica del vent xocat de l'estrella, que s'escalfa fins a desenes de milers de graus. Això ens ha permès estudiar la forma de la regió d'interacció, determinada principalment per la potència del púlsar, i fer un càlcul teòric de l'emissió en raigs X tèrmics. Hem aplicat aquest model al sistema LS 5039 i hem pogut determinar la potència del púlsar, fet important per a la modelització de l'emissió no tèrmica de la font. Finalment, presentem la cerca d'emissió de raigs gamma provinent de sistemes binaris fins ara no detectats. Una campanya simultània en raigs X i raigs gamma ens va permetre seleccionar les dades de molt alta energia del microquàsar Sco X-1 en funció de l'estat d'acreció sobre l'objecte compacte. Tot i no detectar la font en raigs gamma, els límits superiors obtinguts permeten restringir les propietats físiques de Sco X-1 rellevants per a l'emissió en molt alta energia.

Page generated in 0.0248 seconds