• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 136
  • 7
  • 1
  • Tagged with
  • 144
  • 144
  • 96
  • 76
  • 69
  • 55
  • 43
  • 36
  • 35
  • 30
  • 29
  • 29
  • 24
  • 21
  • 21
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
91

Análise de estruturas de madeira, com e sem impregnação de resina poliuretana derivada do óleo de mamona, aplicadas em linhas de distribuição de energia elétrica / Wooden analysis of structures, with and without polyurethane resin impregnation derivative of the oil of mamona, applied in lines of distribution of electric energy

João Paulo Motta de Godoy 25 August 2006 (has links)
As empresas concessionárias de energia elétrica convivem com elevados custos de manutenção em suas redes de distribuição de energia elétrica; em particular um dos motivos está ligado a preço e durabilidade de cruzetas de madeira, seja na sua instalação inicial, seja na sua troca que pode ocorrer freqüentemente, havendo a necessidade de utilização de madeiras nobres em princípios as quais, além do preço, sofrem restrições ambientais em seus usos. Este trabalho visa à análise destas vigas de madeira, do ponto de vista de ensaios mecânicos e suas simulações computacionais, com base em madeiras com menores restrições ambientais, submetidas ou não a impregnação com resina poliuretana derivada do óleo de mamona. É apresentado, também, um texto para o auxílio de futuros leitores e usuários na aplicação do software ANSYS. / The power supply dealership companies live together with high maintenance costs on electrical systems, in private one of reasons is linked to the cost and durability of wood crossarms, either in its initial installation, either in its exchange that can occur frequently, having the necessity of noble wood use in principles which, beyond the price, suffer enviromental restrictions in its uses. This work aims at to the analysis of these beams wooden, of the point of view of mechanical tests and its computational simulation, on the basis of wood with lesser enviromental restrictions, submitted or not to the impregnation with castor-oil polyurethane resin. It is presented, also, a text for the aid of reading and using futures in the application of software ANSYS.
92

Fault location in power distribution networks with distributed generation. / Localização de faltas em redes de distribuição de energia elétrica com a presença de unidades de geração distribuída.

Laiz de Carvalho Souto 14 April 2016 (has links)
This research presents the development and implementation of fault location algorithms in power distribution networks with distributed generation units installed along their feeders. The proposed algorithms are capable of locating the fault based on voltage and current signals recorded by intelligent electronic devices installed at the end of the feeder sections, information to compute the loads connected to these feeders and their electric characteristics, and the operating status of the network. In addition, this work presents the study of analytical models of distributed generation and load technologies that could contribute to the performance of the proposed fault location algorithms. The validation of the algorithms was based on computer simulations using network models implemented in ATP, whereas the algorithms were implemented in MATLAB. / Esta pesquisa apresenta o desenvolvimento e a implementação de algoritmos para localização de faltas em redes primárias de distribuição de energia elétrica que possuem unidades de geração distribuída conectadas ao longo dos seus alimentadores. Esses algoritmos são capazes de efetuar a localização de faltas utilizando registros dos sinais de tensões e correntes realizados por dispositivos eletrônicos inteligentes, instalados nas saídas dos alimentadores de distribuição, além de informações que permitam determinar os valores das cargas conectadas nesses alimentadores, características elétricas, e o estado operativo da rede de distribuição. Ademais, este trabalho apresenta o estudo de modelos analíticos de unidades de geração distribuída e de cargas que poderiam contribuir positivamente com o desempenho dos algoritmos propostos. A validação dos algoritmos foi realizada através de simulações computacionais, utilizando modelos de rede implementados em ATP e os algoritmos foram implementados em MATLAB.
93

Emprego de mapas auto-organizáveis para localização de faltas em redes de distribuição

Cavalheiro, Franciele Cristina 19 October 2012 (has links)
Submitted by Sandro Camargo (sandro.camargo@unipampa.edu.br) on 2015-05-09T19:03:09Z No. of bitstreams: 1 107110001.pdf: 3453553 bytes, checksum: fb266cf11dce80833ef41b2adb20cd21 (MD5) / Made available in DSpace on 2015-05-09T19:03:09Z (GMT). No. of bitstreams: 1 107110001.pdf: 3453553 bytes, checksum: fb266cf11dce80833ef41b2adb20cd21 (MD5) Previous issue date: 2012-10-19 / As distribuidoras de energia elétrica devem estar preparadas para restabelecer o fornecimento de forma ágil, sempre respeitando os critérios de segurança e os índices de continuidade e qualidade compatíveis com o estabelecido na legislação vigente. A possibilidade de localizar defeitos remotamente acelera o processo de restabelecimento. Apesar dos próprios relés e religadores microprocessados fornecerem uma indicação com base na impedância de curto-circuito, ela não é precisa para sistemas de distribuição, uma vez que as redes apresentam várias bifurcações (ramais) protegidas por elementos fusíveis e diferentes bitolas de condutores. Entretanto, atualmente há vários métodos como revelam as pesquisas, que tentam estabelecer maior precisão dos dados e resultados ali envolvidos, buscando criar uma inovação e satisfação às empresas do setor elétrico. Assim, a proposta deste projeto é desenvolver uma metodologia diferencial para localização de faltas em redes de distribuição a partir de estudos da rede combinados com a monitoração remota de dispositivos de proteção (relés e religadores microprocessados). Estas variáveis de entrada: corrente de carga (corrente pré-falta), corrente de curto-circuito, corrente pós-falta; serão obtidas em tempo real pelo SCADA no momento da ocorrência de uma falta na rede. As medidas obtidas serão comparadas e classificadas por Mapas Auto-Organizáveis ou SOM (Self-Organizing Map) de acordo com os padrões de dados simulados pelos estudos da rede. A partir do método proposto será possível estimar o local do defeito ocorrido na rede elétrica por meio do mapa que melhor se identifica com os dados medidos. Essa pesquisa foi aplicada no estudo de caso de uma concessionária da região central gaúcha, a qual alcançou resultados bastante satisfatórios, obtidos a partir de dados reais. / The power utilities must be prepared to restore the supply in an agile way constantly respecting the safety criteria and indexes of continuity and quality consistent with the current legislation. The ability to remotely locate defects accelerates this healing process. Despite own microprocessor relays and reclosers provide an indication based on the short circuit impedance, it is not applicable to distribution systems, since the networks present various bifurcations (branch lines) protected by fuse elements and different wire gauges. However, today there are several methods such as surveys show, trying to establish more precisely the data and results here involved, seeking to create an innovation and satisfaction to the electric companies. Thus, the aim of this project is to develop a methodology for distinct fault location in distribution feeders. It will combine network studies with remote monitoring of protective devices (microprocessor relays and reclosers). These input variables: load current (pre-fault current), short circuit current, post-fault current; will be obtained in real time by SCADA when a fault occurs in the network. These measures will be compared and ranked by Self- Organizing Maps (SOM) according to the patterns obtained by simulation studies of the network. With this method, it will be possible to assess the location of the defect occurring in the power grid, identifying the best map that resembles with the measured data. This research was applied in a power utility in the South of Brazil as case study, which achieved satisfactory results obtained from real data.
94

Metodologia para desenvolvimento e aplicação de um emulador de redes elétricas inteligentes em ambiente controlado. / Methodology for developing and application of a Smart Grid emulator in a controlled environment.

Luiz Henrique Leite Rosa 25 June 2018 (has links)
O presente trabalho visa propor uma metodologia para desenvolvimento e aplicação de um inovador emulador de redes elétricas inteligentes (REIs) para testes sistêmicos de funcionalidades de Smart Grids envolvendo dispositivos inteligentes (hardware) e sistemas de tecnologia da informação (software) em ambiente laboratorial. Além de dar uma dimensão da importância dos laboratórios de redes elétricas inteligentes para a pesquisa do tema, o levantamento bibliográfico apresentado neste trabalho permite concluir que as pesquisas envolvendo hardware-in-the-loop (HIL) tendem a concentrar suas análises nos equipamentos de hardware testados, como dispositivos de medição, equipamentos de potência (inversores de frequência e outros), dispositivos de controle e seus algoritmos e não em estudos que envolvam análises mais sistêmicas e interações dos dispositivos com sistemas de TI normalmente presentes nos Centros de Operação da Distribuição (COD), os quais cumprem papéis cada vez mais importantes nas funcionalidades de Redes Inteligentes. A metodologia proposta parte da premissa de que um ambiente para testes de funcionalidades de Smart Grids deve permitir análises sistêmicas, não apenas focadas nos dispositivos de controle de uma porção particular da rede ou sistemas de automação específicos, mas devem envolver a maior porção de rede possível e necessária para a correta representação das redes elétricas inteligentes. Neste sentido, a metodologia define e caracteriza os principais módulos e etapas de desenvolvimento de um emulador de redes elétricas inteligentes, ao mesmo tempo em que propõe soluções para os desafios de integração destes módulos, aplicando conceitos de hardware-in-the-loop, software-in-the-loop (SIL), e simulação com sincronização orientada a evento, além de propor soluções com simulação de sistemas de potência em regime permanente e hardware de baixo custo que permitiram o desenvolvimento do emulador de redes em laboratório de Smart Grid. As principais características do emulador de REIs desenvolvido e implementado no laboratório de Smart Grid, conforme a metodologia proposta, também são descritas neste trabalho. Por fim, são apresentados os casos teste, mais especificamente provas de conceito, envolvendo redes de teste IEEE/PES e redes reais das concessionárias do grupo EDP, financiador do projeto de implantação do laboratório no âmbito do Programa de P&D ANEEL, os quais serviram de base para a avaliação do desempenho do emulador e discussões finais sobre as contribuições da metodologia de desenvolvimento proposta neste trabalho. / This work aims to proposing a methodology for the development and application of an innovative Smart Grid emulator for systemic testing of Smart Grids functionalities involving intelligent devices and information technology systems in a laboratory environment. Besides demonstrating the importance of the Smart Grid for the subject research, the literature review clarifies that the research involving hardware-in-the-loop (HIL) tends to concentrate its analyses in the equipment under test, such as power devices, control devices and their algorithms. Instead, it should consider systemic studies involving the interaction of these devices with Operation Centre IT systems, so relevant to the Smart Grid functionalities. The proposed methodology is based on the premise that an environment for testing Smart Grids functionalities should allow systemic analysis instead of focusing only on control devices of a specific area or specific automation systems. Instead, it should involve a more detailed representation of the network that is necessary for the correct representation of the Smart Grid. In this direction, the methodology defines and characterizes the development stages and main modules of a Smart Grid emulator and proposes solutions for integration issues. It applies concepts of hardware-in-the-loop, software-in-the-loop (SIL), simulation with event-driven synchronization, besides steady-state power simulation and low-cost hardware solutions that enabled the development of the Power grid emulator at a Smart Grid laboratory. The main features of the Smart Grid emulator developed and implemented at the Smart Grid laboratory, according to the proposed methodology, are also described in this work. Finally, the description of the Smart Grid laboratory, test cases and proofs of concepts involving IEEE/PES test feeders and real networks of the EDP utility, sponsor of the project for laboratory implementation under the ANEEL R&D Program, are presented to prove the Emulator performance and to discuss the contribution of the methodology herein proposed.
95

Impacto de redes de distribuição com massiva conexão de geradores fotovoltaicos na estabilidade de tensão de longo-prazo em sistemas de potência

BARATA, Heitor Alves 31 March 2017 (has links)
Submitted by Hellen Luz (hellencrisluz@gmail.com) on 2017-07-04T18:18:09Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_ImpactoRedesDistribuicao.pdf: 3740924 bytes, checksum: 3fc693c9e32013dada9cf9bf3be0bcd8 (MD5) / Approved for entry into archive by Irvana Coutinho (irvana@ufpa.br) on 2017-08-17T16:36:35Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_ImpactoRedesDistribuicao.pdf: 3740924 bytes, checksum: 3fc693c9e32013dada9cf9bf3be0bcd8 (MD5) / Made available in DSpace on 2017-08-17T16:36:35Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_ImpactoRedesDistribuicao.pdf: 3740924 bytes, checksum: 3fc693c9e32013dada9cf9bf3be0bcd8 (MD5) Previous issue date: 2017-03-31 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Esta dissertação visa mostrar o impacto de geradores fotovoltaicos distribuídos, conectados nas redes de distribuição, na estabilidade de tensão de longo-prazo usando simulação completa no domínio do tempo. O efeito de diferentes níveis de penetração da geração fotovoltaica é investigado. Também são investigados diferentes modelos de redes de distribuição com geração distribuída: 1) Carga e GD representados por modelo ZIP e carga com potência ativa negativa do tipo corrente constante, respectivamente, na subestação (SE); 2) Carga e GD representados por modelo ZIP e equivalente dinâmico, respectivamente, na SE; 3) Carga e GD representados por modelo ZIP e modelo dinâmico, respectivamente, distribuídos ao longo de uma rede de distribuição de MT. Equipamentos como transformadores com comutação de tape sob carga (OLTC, do inglês, “On-Load Tap Changer”), limitadores de sobrecorrente de excitação (OEL, do inglês, “Overexcitation Limiter”), cargas estáticas e autotransformadores reguladores de tensão são levados em consideração nas análises, pois afetam significativamente a estabilidade de tensão de longo-prazo. As investigações são realizadas por meio do uso do software de análise de rede (ANAREDE) e do software de análise de transitórios eletromecânicos (ANATEM), desenvolvidos pelo Centro de Pesquisas de Energia Elétrica (CEPEL). A modelagem estática dos geradores fotovoltaicos é considerada como barras PQ, e a modelagem dinâmica é baseada no modelo PVD1 da WECC (Western Electricity Coordinating Council) implementada via Controle Definido pelo Usuário (CDU) no ANATEM. A proteção mandatória da geração fotovoltaica também é considerada. O sistema de potência estudado é uma junção de um sistema de transmissão de 11 barras com sistemas de distribuição da UKGDS (United Kingdom Generic Distribution System) de 76 barras cada. / This dissertation aims to show the impact of distributed photovoltaic generators connected to distribution networks on long term voltage stability using full time simulation. The effect of different penetration levels of photovoltaic generation is investigated. Different distribution network models considering distributed generation (DG) connections is also investigated: 1) Load and DG represented by ZIP model and negative active power loads, respectively, connected to the substation bus; 2) Load and DG represented by ZIP model and dynamic equivalent, respectively, connected to the substation bus; 3) Load and GD represented by ZIP model and dynamic model, respectively, distributed along a MV distribution network. Equipments such as On-Load Tap Changer (OLTC) transformers, Overexcitation Limiter (OEL), static loads and step voltage regulators are taken into account in the analyzes, since they significantly affect the long-term voltage stability. The investigations were conducted using both the power flow software ANAREDE and transient stability simulator ANATEM, developed by the Electrical Energy Research Center (CEPEL). For the purpose of power flow studies, photovoltaic generators are modeled as PQ buses with Q=0. The modelling of photovoltaic generators for dynamic studies is based on WECC (Western Electricity Coordinating Council) model, wich was inserted into file User Defined Controller (CDU) from ANATEM. The undervoltage protection of photovoltaic generator is also considered. The case studies were performed on a combined transmission and distribution model.
96

Desenvolvimento de um programa computacional para balanceamento de redes de distribuição de ar. / A development of software to balance air distribution net.

Bendezu Hernández, Luis Miguel Teófanes 25 February 2010 (has links)
O balanceamento de uma rede de distribuição de ar consiste em estabelecer as vazões corretas nos elementos terminais conforme previsto no projeto. A revisão bibliográfica apontou que o balanceamento aplicado à distribuição de ar passou a ser considerado no final dos anos de 1960. A aplicação de modelos matemáticos com a simulação do escoamento do ar nos dutos das redes tem início no final dos anos 80. No presente trabalho o objetivo foi estudar metodologia para simulação e balanceamento de redes de distribuição de ar, implementando-a em um programa de computador. Foram estudados diferentes métodos para realizar o balanceamento: método proporcional, método T e o método direto. Foi adotado o direto, em que as vazões são impostas e as diferenças de pressão determinadas para escoamentos em caminhos em paralelo. Mediante o uso de conceitos que fazem analogia entre a fluido-dinâmica e a eletricidade, foi desenvolvido um algoritmo e elaborado um programa de computador. O aplicativo desenvolvido possui 6 etapas principais: caracterização da rede, perda distribuída, perda localizada, perda total, simulação do escoamento e comparação de caminhos. A partir de um estudo de caso, o programa foi testado simulando uma rede de distribuição. Esta mesma rede teve seu balanceamento avaliado por cálculos em planilha eletrônica. Os resultados do estudo de caso com os valores de pressão para todos os trechos da rede, assim como as diferenças de pressão que definem a magnitude do balanceamento foram comparados e estão coincidentes dentro da margem esperada. / The balancing of a net air distribution consists in establishment the correct flowrate in the terminals elements according the design. The bibliographic review show that the balancing applied in air distribution are consider at the 60`s. In the end of the 80\\2019s the mathematics models beginning applied to air flow simulation in ducts. In the present work the objective is studies the methodology to simulation and balancing air distribution nets using software. Different methods are studies to apply in balance: proportional method, T method and direct method. The direct method is adopted, which the flowrate is fixed and the pressure difference is obtained for the parallel paths. Using fluid-dynamics and electrical analogy concepts an algorithm was developed and a software was prepared. The applicatory developed was divided in 6 main stages: net characterization, continuous losses, local losses, total losses, flow simulation and path comparing. Using a case study the software was tested and the distribution net was simulating. This same net was balancing evaluated by a computational spreadsheet. The case study results present the values of pressure for the sections of the net, and the pressure differences to obtained the balancing. This values was consider coincident with the expected.
97

Análise de estruturas de madeira, com e sem impregnação de resina poliuretana derivada do óleo de mamona, aplicadas em linhas de distribuição de energia elétrica / Wooden analysis of structures, with and without polyurethane resin impregnation derivative of the oil of mamona, applied in lines of distribution of electric energy

Godoy, João Paulo Motta de 25 August 2006 (has links)
As empresas concessionárias de energia elétrica convivem com elevados custos de manutenção em suas redes de distribuição de energia elétrica; em particular um dos motivos está ligado a preço e durabilidade de cruzetas de madeira, seja na sua instalação inicial, seja na sua troca que pode ocorrer freqüentemente, havendo a necessidade de utilização de madeiras nobres em princípios as quais, além do preço, sofrem restrições ambientais em seus usos. Este trabalho visa à análise destas vigas de madeira, do ponto de vista de ensaios mecânicos e suas simulações computacionais, com base em madeiras com menores restrições ambientais, submetidas ou não a impregnação com resina poliuretana derivada do óleo de mamona. É apresentado, também, um texto para o auxílio de futuros leitores e usuários na aplicação do software ANSYS. / The power supply dealership companies live together with high maintenance costs on electrical systems, in private one of reasons is linked to the cost and durability of wood crossarms, either in its initial installation, either in its exchange that can occur frequently, having the necessity of noble wood use in principles which, beyond the price, suffer enviromental restrictions in its uses. This work aims at to the analysis of these beams wooden, of the point of view of mechanical tests and its computational simulation, on the basis of wood with lesser enviromental restrictions, submitted or not to the impregnation with castor-oil polyurethane resin. It is presented, also, a text for the aid of reading and using futures in the application of software ANSYS.
98

Metodologia para desenvolvimento e aplicação de um emulador de redes elétricas inteligentes em ambiente controlado. / Methodology for developing and application of a Smart Grid emulator in a controlled environment.

Rosa, Luiz Henrique Leite 25 June 2018 (has links)
O presente trabalho visa propor uma metodologia para desenvolvimento e aplicação de um inovador emulador de redes elétricas inteligentes (REIs) para testes sistêmicos de funcionalidades de Smart Grids envolvendo dispositivos inteligentes (hardware) e sistemas de tecnologia da informação (software) em ambiente laboratorial. Além de dar uma dimensão da importância dos laboratórios de redes elétricas inteligentes para a pesquisa do tema, o levantamento bibliográfico apresentado neste trabalho permite concluir que as pesquisas envolvendo hardware-in-the-loop (HIL) tendem a concentrar suas análises nos equipamentos de hardware testados, como dispositivos de medição, equipamentos de potência (inversores de frequência e outros), dispositivos de controle e seus algoritmos e não em estudos que envolvam análises mais sistêmicas e interações dos dispositivos com sistemas de TI normalmente presentes nos Centros de Operação da Distribuição (COD), os quais cumprem papéis cada vez mais importantes nas funcionalidades de Redes Inteligentes. A metodologia proposta parte da premissa de que um ambiente para testes de funcionalidades de Smart Grids deve permitir análises sistêmicas, não apenas focadas nos dispositivos de controle de uma porção particular da rede ou sistemas de automação específicos, mas devem envolver a maior porção de rede possível e necessária para a correta representação das redes elétricas inteligentes. Neste sentido, a metodologia define e caracteriza os principais módulos e etapas de desenvolvimento de um emulador de redes elétricas inteligentes, ao mesmo tempo em que propõe soluções para os desafios de integração destes módulos, aplicando conceitos de hardware-in-the-loop, software-in-the-loop (SIL), e simulação com sincronização orientada a evento, além de propor soluções com simulação de sistemas de potência em regime permanente e hardware de baixo custo que permitiram o desenvolvimento do emulador de redes em laboratório de Smart Grid. As principais características do emulador de REIs desenvolvido e implementado no laboratório de Smart Grid, conforme a metodologia proposta, também são descritas neste trabalho. Por fim, são apresentados os casos teste, mais especificamente provas de conceito, envolvendo redes de teste IEEE/PES e redes reais das concessionárias do grupo EDP, financiador do projeto de implantação do laboratório no âmbito do Programa de P&D ANEEL, os quais serviram de base para a avaliação do desempenho do emulador e discussões finais sobre as contribuições da metodologia de desenvolvimento proposta neste trabalho. / This work aims to proposing a methodology for the development and application of an innovative Smart Grid emulator for systemic testing of Smart Grids functionalities involving intelligent devices and information technology systems in a laboratory environment. Besides demonstrating the importance of the Smart Grid for the subject research, the literature review clarifies that the research involving hardware-in-the-loop (HIL) tends to concentrate its analyses in the equipment under test, such as power devices, control devices and their algorithms. Instead, it should consider systemic studies involving the interaction of these devices with Operation Centre IT systems, so relevant to the Smart Grid functionalities. The proposed methodology is based on the premise that an environment for testing Smart Grids functionalities should allow systemic analysis instead of focusing only on control devices of a specific area or specific automation systems. Instead, it should involve a more detailed representation of the network that is necessary for the correct representation of the Smart Grid. In this direction, the methodology defines and characterizes the development stages and main modules of a Smart Grid emulator and proposes solutions for integration issues. It applies concepts of hardware-in-the-loop, software-in-the-loop (SIL), simulation with event-driven synchronization, besides steady-state power simulation and low-cost hardware solutions that enabled the development of the Power grid emulator at a Smart Grid laboratory. The main features of the Smart Grid emulator developed and implemented at the Smart Grid laboratory, according to the proposed methodology, are also described in this work. Finally, the description of the Smart Grid laboratory, test cases and proofs of concepts involving IEEE/PES test feeders and real networks of the EDP utility, sponsor of the project for laboratory implementation under the ANEEL R&D Program, are presented to prove the Emulator performance and to discuss the contribution of the methodology herein proposed.
99

Controle de tensão em redes de baixa tensão com alta penetração de geração fotovoltaica /

Leon Colqui, Jaimis Sajid January 2017 (has links)
Orientador: Antonio Padilha Feltrin / Resumo: Este trabalho apresenta uma proposta de estratégia global de controle de tensão que emprega programação não linear e duas extensões de estratégias de controle de tensão, encontrados na literatura. O principal objetivo destas estratégias é solucionar o problema de aumento de tensão nas redes de distribuição de baixa tensão, causado pela injeção de potência do gerador fotovoltaico distribuído. Estas estratégias de controle de tensão foram implementadas e analisadas a fim de verificar a sua eficácia e comparar os seus comportamentos. Para os testes, foram considerados a operação de geradores fotovoltaicos monofásicos e trifásicos distribuídos em um sistema teste de distribuição em baixa tensão. Os resultados mostraram que depois da aplicação das estratégias de controle, os perfis de tensão em regime permanente ficaram dentro da faixa de tensão permitida, obtendo-se uma mínima redução de potência ativa injetada dos geradores fotovoltaicos com os seus correspondentes fatores de potência. / Abstract: This work presents a proposal of a global voltage control strategy that use nonlinear programming and two extensions of voltage control strategies that are found in the literature. The main objective of these strategies is to solve the problem of voltage increase in low voltage distribution networks, caused by the power injection of the distributed photovoltaic generator. These voltage control strategies have been implemented and analyzed in order to verify their effectiveness and compare their behaviors. For the test, the operation of single-phase and three-phase photovoltaic generators distributed in a low voltage distribution test system were considered. The results showed that after the application of the control strategies, the steady-state voltage profiles were whihin the allowed voltage range, obtaining a minimum reduction of the active power injection of the photovoltaic generators with their corresponding powe factors. / Mestre
100

Metodologia para avaliação do risco de ilhamento não intencional de geradores eólicos distribuídos

Vieira, Thiago Correia January 2014 (has links)
Orientador: Prof. Dr. Ahda Pionkoski Grilo Pavani / Dissertação (mestrado) - Universidade Federal do ABC, Programa de Pós-Graduação em Engenharia Elétrica, 2014. / O ilhamento não intencional ocorre quando a proteção não é capaz de detectar a operação ilhada de parte do sistema de distribuição. Estas falhas ocorrem para condições específicas de geração e carga do subsistema ilhado, nas quais as variações de tensão e frequência após o ilhamento não são suficientes para sensibilizar a proteção. Neste trabalho é apresentada uma metodologia para o cálculo do índice de risco de ilhamento não intencional de geradores eólicos distribuídos, considerando que estes geradores empregam relés de sub/sobrefrequência e sub/sobretensão para proteção anti-ilhamento. A metodologia desenvolvida utiliza curvas características de velocidade de vento de uma região e curvas de carga para identificar as possíveis condições de operação do sistema. Com a aplicação da metodologia proposta é possível avaliar o risco da proteção anti-ilhamento baseada em relés de sub/sobretensão e sub/sobrefrequência não detectar o ilhamento. Como resultado, a concessionária poderá avaliar se somente a proteção anti-ilhamento baseada nestes relés é suficiente, ou se devido ao alto risco de não detecção esquemas mais sofisticados devem ser empregados. / The unintentional islanding occurs when the protection is not able to detect the islanded part of the distribution system operation. These failures occur for specific conditions of generation and load islanded subsystem in which the variations of voltage and frequency after islanding are not sufficient to sensitize protection. In this work a methodology to calculate the unintentional islanding risk index of distributed wind generators is presented, considering that these generators employ under/overfrequency and under/overvoltage protection relays for anti-islanding. The methodology uses the characteristic curves of wind speed in a region and load curves to identify the possible operating conditions of the system. Proposed methodology can assess the risk of anti-islanding protection based on under/overvoltage and under/overfrequency relays not detect islanding condition. As a result, the utility can only assess whether the anti-islanding protection based on these relays is sufficient, or if due to the high risk of failure to detect more sophisticated schemes must be employed.

Page generated in 0.1721 seconds