• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 486
  • 8
  • 8
  • 8
  • 8
  • 7
  • 7
  • 3
  • 3
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 505
  • 146
  • 143
  • 93
  • 57
  • 56
  • 52
  • 49
  • 40
  • 39
  • 38
  • 38
  • 37
  • 36
  • 32
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
161

Modelagem térmica da coluna de destilação de um ciclo de refrigeração por absorção de amônia/água. / Thermal modeling of distillation column of a ammonia/water refrigeration cycle.

Zavaleta Aguilar, Elí Wilfredo 22 February 2010 (has links)
O objetivo deste trabalho é apresentar a análise de uma coluna de destilação de pratos perfurados com vertedor segmentado em condições de regime permanente para um ciclo de refrigeração por absorção com capacidade de 5 toneladas de refrigeração que trabalha com amônia/água. Para garantir que o ciclo de refrigeração trabalhe em condições de projeto, a coluna de destilação deve proporcionar vapor com elevado grau de pureza de amônia. Os balanços de massa e de energia da coluna foram realizados com o método de Ponchon-Savarit o qual considera escoamentos do líquido e do vapor na saída de cada prato em equilíbrio termodinâmico. Para estas condições foi calculado como 4 o número de pratos ideais e a alimentação à coluna seria acima do segundo prato. A análise de sensibilidade do fator de refluxo indica que é um parâmetro importante na análise econômica do projeto, já que dele depende o alto custo inicial de construção da coluna, ou as maiores despesas de gasto em combustível no funcionamento do ciclo. As considerações hidráulicas, as quedas pressão e as razões de fluxos mássicos deram como resultado a geometria interna da coluna, a qual resultou satisfatória para os parâmetros de projeto recomendados, embora tenham sido usadas correlações da área de petróleo, petroquímica e de destilação de bebidas alcoólicas. A distância entre pratos é uma medida da compactabilidade da coluna e ficou muito dependente, assim como outras medidas do prato, da altura do vertedor a qual foi encontrada como ótima para valores entre 4 mm e 8 mm. A geometria do prato resulta ser sensível à carga de vapor e, em menor grau, à carga do líquido, mostrando-se insensível ao diâmetro do furo. A eficiência da coluna leva em conta fenômenos de transporte no prato que o afasta da condição de idealidade. Calculou-se uma eficiência da coluna de 50 %. Este valor baixo se deve principalmente ao baixo valor da inclinação da curva de equilíbrio amônia/água no início da seção de esgotamento e à baixa razão da vazão molar do vapor dividido pela vazão molar do líquido, nessa seção. / The objective of this work is to present the analysis of a segmented weir sieve tray distillation column in steady-state conditions for a 5 Tons of Refrigeration ammonia/water absorption refrigeration cycle. For a proper and correct cycle operation, the distillation column should provide ammonia at high degree of purity. Column, mass and energy balances were made using the Ponchon-Savarit method, which considers that the liquid and the vapor leaves the tray at thermodynamic equilibrium. For these conditions it was calculated as being 4 the ideal number of trays and the feeding to the column would be above the second tray. A sensibility analysis of the reflux factor indicates that it is an important project from an economical study, as from that parameter depends the initial cost of the column manufacture, or the expenses whit fuel for the cycle operation. Hydraulic considerations, pressure loss and of mass flow ratios provides the internal geometry of the column, which resulted satisfactory for the project parameters recommended, although, correlations used are more applied in petroleum, petrochemical and alcoholic industries. Tray spacing, which is a measure of the compactness of the column, and other geometric tray values, depend on the weir height. It was found optimal values between 4 mm and 8 mm. The tray geometry is also sensitive, to the vapor load and to the liquid load, at smaller degree, and it is insensible with the hole diameter. The column efficiency depends on the transport phenomena on the tray. This value fixes the tray number at the actual condition. It was calculated an efficiency of the column of 50 %. This low value depends mainly on the low value of the slope of the ammonia/water equilibrium curve below the stripping section and the low value of the molar flow vapor-liquid ratio at this section.
162

Estudo da influência da camada limite hidrodinâmica no desempenho de um tanque vertical de termoacumulação de água gelada durante o ciclo de descarga. / Study of the hydrodynamic boundary layer in the performance of a vertical cold water thermal storage tank during the discharging cycle.

Milaré, Manoel Máximo 15 December 2008 (has links)
Quando água quente é introduzida em um tanque de termoacumulação vertical, durante o ciclo de descarga, ocorre uma mistura parcial dessa água com a água fria armazenada. A intensidade dessa mistura depende de parâmetros geométricos do difusor de entrada e da dinâmica do escoamento no início do processo. Inúmeros estudos têm sido desenvolvidos no intuito de se projetar adequadamente o difusor de entrada, de forma a minimizar essa mistura, que corresponde a uma perda de capacidade do tanque. Porém, há uma outra forma de perda de capacidade do tanque, devida aos efeitos viscosos do escoamento. Quando um fluido escoa dentro de um tubo, há a formação de uma camada limite hidrodinâmica, devida à viscosidade do mesmo. Na região do comprimento hidrodinâmico de entrada, em cada seção transversal do tubo e dentro da camada limite, os efeitos viscosos geram um gradiente (radial) de velocidade. Fora dessa camada (no núcleo), esses efeitos são desprezíveis e o fluido escoa com velocidade uniforme. Porém, ao longo desse comprimento, o movimento do fluido no núcleo é acelerado. O escoamento em um tanque vertical de termoacumulação ocorre na região do comprimento hidrodinâmico de entrada. Considerando que não haja mistura das massas de água quando se inicia a introdução da água quente, irá se forma uma superfície de contato entre as mesmas. Essa superfície, por possuir velocidade no núcleo maior que a velocidade média de descarga, atingirá o difusor de saída mais rapidamente. Assim, para que seja garantida descarga de água na temperatura da água armazenada durante todo o ciclo de descarga, a altura do tanque deverá ser maior que a altura determinada utilizando-se a velocidade média do escoamento, sem considerar os efeitos viscosos (modelo ideal). A diferença entre essas alturas constitui, por si só, uma perda de capacidade do tanque. O estudo dos efeitos do escoamento viscoso no desempenho do tanque mostra que dois números adimensionais surgem naturalmente: o número de Reynolds relativo ao diâmetro, ReØ, necessário para se determinar o comprimento hidrodinâmico de entrada, e o número f, que relaciona a posição da superfície de contato das massas de água com o comprimento hidrodinâmico de entrada. Os resultados mostram que a perda devida aos efeitos do escoamento viscoso pode não ser desprezível e que a escolha do diâmetro do tanque é de fundamental importância para minimizar esses efeitos. Também, a análise qualitativa do escoamento sugere que as perdas de capacidade do tanque nos ciclos de descarga e carga não são iguais, pois a diferença de densidade das massas de água age de maneira diversa em cada caso. / When warm water is introduced into a vertical thermal storage tank, during the discharging cycle, a partial mixing between it and the cold water stored will occur. The extension of that mixing depends upon diffuser geometric parameters and the dynamics of the flow at the beginning of the process. So many works have been developed, trying to find the better diffuser design so that undesired mixing can be minimized. The mixing is accounted as a tank loss of capacity. But, there is another kind of tank loss of capacity due to viscous effects of the flow. When a fluid flows inside a tube, it forms a boundary layer due to fluid viscosity. At the hydrodynamic entry length region, in each cross section of the tube and inside the boundary layer, the viscous effects create a (radial) velocity gradient. Outside of the boundary layer (inside the core), the viscous effects are negligible and the fluid flows with a uniform velocity. However, along the entry length that velocity gets higher at each section. In a vertical thermal storage tank, water flows at the hydrodynamic entry length region. Considering that no mixing occurs at the beginning of the warm water introduction at the tank top, it will form a contact surface between the warm water and the cold one already in the tank. That contact surface has the velocity inside the core higher than the mean discharging flow velocity and it will reach the outlet diffuser at the tank bottom more quickly. Then, the tank height must be greater than that determined using the mean velocity flow alone without any viscous effect (ideal model), so that the discharging flow has the same stored water temperature during all the discharging cycle. The difference between those heights constitutes itself a tank loss of capacity. The study of the viscous effects on the tank performance shows that two non-dimensional parameters appear naturally: the Reynolds number related to the tank diameter, ReØ, used for determining the hydrodynamic entry length, and the f number that relates the position of the contact surface of the water masses to the hydrodynamic entry length. Results show that the loss due to viscous effects, may not be negligible and the choice of the tank diameter is essential to minimizes those effects. Also, there is a difference between tank losses of capacity during the charging and discharging cycles, since the effect of the density difference between the warm and cold water works in a different way in each one of those two situations.
163

Simulação transiente de um sistema de refrigeração doméstico: análise paramétrica / Transient simulation of a domestic refrigeration system: parametric analysis

Rangel, Sergio de Camargo 07 December 2007 (has links)
No presente trabalho são apresentados resultados de simulação numérica transiente de um sistema de refrigeração doméstico de compressão a vapor considerando o procedimento descrito por JAKOBSEN (1995). O modelo matemático empregado se baseia num sistema de equações algébrico-diferenciais (EAD) de primeira ordem, obtido a partir do balanço de energia nos diferentes componentes do sistema de refrigeração, e de algumas outras relações necessárias para simular o comportamento global do sistema de refrigeração. O sistema de equações resultante é resolvido numericamente no software livre WinDali, da Universidade Técnica de Dinamarca. Dito software permite resolver sistemas de EADs que apresentam descontinuidades matemáticas usando o método de Runge- Kutta de quarta ordem. O modelo matemático empregado permite calcular a eficiência do sistema de refrigeração, predizer o consumo de energia, caracterizar termodinamicamente o sistema de refrigeração e suas interações, e descrever quantitativamente as perdas termodinâmicas (geração de entropia) do sistema funcionando em regime de operação. Esses resultados são obtidos em função da estratégia de controle do compressor, eficiência do compressor e do dimensionamento dos diferentes componentes do sistema de refrigeração. Os resultados comprovam que o modelo matemático e o programa computacional empregados permitem descrever corretamente o comportamento de um sistema de refrigeração doméstico, resultando numa ferramenta muito útil para otimização de refrigeradores domésticos. / In the present work are presented transient numerical simulation results of a vapor compression domestic refrigeration system considering the procedure described by JAKOBSEN (1995). The employed mathematical model is based on first order differential-algebraic equation (DAE) systems, obtained from energy balance in the different components of the refrigeration system, and from others relations that are necessary to simulate the global behavior of a refrigeration system. The resulting equation system is solved numerically in the free software WinDali developed at Technical University of Denmark. This software allows solving DAE systems that present mathematical discontinuities, using the Runge-Kutta method of fourth order. The employed mathematical model allows calculating the refrigeration system efficiency, predict the energy consumption, thermodynamically characterize the refrigeration system and its interactions and quantitatively describe the thermodynamic losses (entropy generation) of the system running in the operation regime. These results are obtained as a function of the compressor control strategy, compressor efficiency, and sizing of different components of the refrigeration system. The results confirm that the mathematical model and the computational program allow describing correctly the behavior of a domestic refrigeration system, resulting in a very useful tool for optimization of domestic refrigerators.
164

Projeto e simulação de resfriadores de líquidos. / Chillers design and simulation.

Lopes, Marco Aurélio 20 March 2007 (has links)
Na última década, o mundo passou por uma transformação importante. O aumento do número de empresas e a globalização fizeram com que a concorrência obrigasse os diversos setores da indústria a aumentarem a produtividade e a qualidade para se manterem competitivos. Neste contexto, os sistemas de refrigeração proporcionam redução do tempo de ciclo em diversos processos de manufatura e, conseqüentemente, aumento de produtividade, maior confiabilidade, repetibilidade e qualidade do produto acabado. Diante desse cenário, fica evidente a importância de um estudo sobre refrigeração industrial. Neste trabalho é apresentado um estudo do projeto, dimensionamento e simulação de resfriadores de líquidos utilizados em refrigeração industrial. São analisados os principais aspectos relevantes ao projeto do sistema hidráulico e de refrigeração, além do dimensionamento dos principais componentes do equipamento. Após análise do projeto, são desenvolvidos modelos matemáticos para simulação do sistema de refrigeração em regime permanente. Os resultados de simulação são comparados com resultados obtidos em bancada experimental, verificando-se diferenças máximas de 3ºC na temperatura de evaporação, 2ºC na temperatura de condensação e 20% na capacidade efetiva de refrigeração. Adicionalmente, os resultados obtidos mostram que o equipamento não atinge a capacidade projetada e são propostas alterações no compressor e no condensador a ar. É sugerida a substituição do compressor, o aumento da área de troca do condensador e diminuição do número de aletas por polegadas para aumentar a vazão de ar. Por fim, o desenvolvimento do trabalho resulta em um programa de simulação de resfriadores de líquidos, que constitui importante ferramenta de análise e otimização. / In the last decade, the world passed trough an important transformation. The raise in the number of companies and globalization obligated the industry to increase production and quality to be competitive. This scene turns clear the importance of researches in the industrial refrigeration area. The cooling systems allow reduction in the manufacture time cycle, and consequently, rise in productivity, more reliability and quality of the final product. In this work, an analysis of the design, dimensioning and simulation of liquid chillers used for industrial refrigeration is presented. The main aspects of the hydraulic and refrigeration systems and the dimensioning of the components used in the equipment are analyzed. After the analysis of the project, a mathematical model of the system for simulation in equilibrium state is developed. The results of the simulations are compared with the data obtained during the tests and the maximum differences was 3ºC in the evaporating temperature, 2ºC in condensing temperature and 20% of cooling capacity. Additionally, the results show that the equipment hasn?t achieved the design capacity and changes were proposed in the compressor and air cooled condenser. The equipment has been tested and the data obtained has been compared with the simulation. It?s suggested to change the compressor for another model with higher capacity, to increase the heat exchange area and to reduce the number of fins in the air cooled condenser. Finally, the development of this work resulted in a simulation program of liquid coolers, very useful tool for analysis and optimization.
165

Thermodynamic analysis of gas turbine cycle using inlet air cooling methods

Ana Paula Pereira dos Santos 10 February 2012 (has links)
This work focuses on a comparative analysis among three compressor inlet air cooling techniques using a thermodynamic approach to simulate the gas turbine cycle. Firstly, a Base Case is tested to determine the gas turbine performance without any cooling method. The effect of site altitude on the power output gas turbine even without any cooling technique is also simulated. After, the evaporative cooling, absorption and mechanical refrigeration chillers are studied under different ambient temperature and relative humidity. Results showed that the cooling potential of the evaporative system is dependent of its effectiveness, while the absorption chiller cooling load is determined by pre-established compressor inlet air temperature. For the mechanical chiller method, however, it is necessary also to consider the power demand required by the vapour refrigerant compression. It is important to observe that although the absorption chiller has been the more suitable cooling method, it is only a realizable solution if the exhaust gases heat are available and with adequate discharge temperature. Furthermore, the gas turbine analysis is carried out at two brazilian locations: Campos/RJ and Goiania/GO. The monthly power output gain offered by the evaporative cooling method is low due to its intrinsic limitation, the ambient wet-bulb temperature. Further, the mechanical chiller system provided a considerable improvement in power output monthly results. However, the best power output increment is reached when the absorption chiller system is employed. Besides, a preliminary economic analysis showed that evaporative cooling offered the lowest unit electric energy cost, but associated with the lesser incremental power generation potential. On the other hand, the chillers systems are more expensive, while provide larger values of incremental electric energy. Results also showed that the cooling techniques allow obtaining a considerable increase in power generation with a lower cost in comparison with the gas turbine plant without any cooling method.
166

Eficiência energética em sistemas de refrigeração industrial : estudo de caso /

Tassini, Jussara Oliveira. January 2012 (has links)
Resumo: Em alguns tipos de indústria, como por exemplo a de laticínios, bebidas e frigoríficos, o sistema de refrigeração é responsável por uma parcela significativa no consumo de energia elétrica. Tendo como objetivo a redução deste consumo, foi realizado um estudo de caso em uma indústria produtora de bebidas, sendo analisados todos os componentes do sistema de refrigeração. O sistema de refrigeração analisado utiliza amônia anidra (NH3) como fluido refrigerante no circuito principal e solução de etanol no circuito secundário, sendo composto por compressores do tipo parafuso, condensadores evaporativos, evaporadores de placas, conjunto de bombas e válvulas expansoras com controle eletrônico. Usualmente, os sistemas de refrigeração atendem diversos processos e etapas de produção, que diferem nos requisitos de temperatura de produto. Além disso, por serem projetados para atender a maior demanda esperada, constituem uma grande oportunidade de otimização nos períodos fora de pico de consumo. Foram descritos e detalhados os componentes do sistema de refrigeração, bem como todas as ações e requisitos necessários para melhoria na eficiência energética da instalação. A implementação destas ações de melhoria de eficiência na planta industrial estudada contou com um investimento total de R$ 302.000,00, e foram responsáveis por um ganho anual de R$ 241.000,00, correspondentes a uma redução no consumo elétrico de 1,7 GWh/ano. O payback simples, portanto, é de 1,25 anos / Abstract: In some types of industry where cooling systems are required, for example, dairy products, beverages and frozen foods, the cooling system is responsible for a significant portion of electricity consumption. Aiming to reduce this consumption, a case study was performed in a beverage industry, and all the refrigeration systems components were analyzed. The cooling system operates using anhydrous ammonia (NH3) as the refrigerant in the main circuit and ethanol solution in the secondary circuit, it consists of screw compressors, evaporative condensers, plate and frame coolers, pumps and expansion valves with electronic control. Usually, refrigeration systems have several processes and production stages to meet for different products, depending on the products temperature requirements. Moreover, they are designed to attain the highest demand expected, which gives a great opportunity to optimize the off-peak periods of consumption. We have described and itemized whole refrigeration systems components, as well as all actions and requirements to improve the energy efficiency of the installation. The energy efficiency improvements actions that were implemented in this industrial plant study had a total investment of R$ 302,000.00. These improvementes resulted in an annual saving of R$ 241,000.00, as well a relative a reduction in electricity consumption of 1,7 GWh/year. Therefore, the simple payback is 1.25 years / Orientador: Pedro Magalhães Sobrinho / Coorientador: José Luz Silveira / Banca: José Alexandre Matelli / Banca: Christian Jeremi Coronado Rodriguez / Mestre
167

Simulation and numerical optimization of diffusion-absorption refrigeration (DAR) cycle powered by solar energy

Pais, Joana Isabel Pereira Malheiro January 2009 (has links)
Tese de mestrado integrado. Engenharia Química. Faculdade de Engenharia. Universidade do Porto, Université de Pau et des Pays de l'Adour. 2009
168

Retificação da alumina com rebolo diamantado usando diferentes métodos de lubri-refrigeração

Fujita, Humberto [UNESP] 04 May 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:29Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-05-04Bitstream added on 2014-06-13T18:50:40Z : No. of bitstreams: 1 fujita_h_me_bauru.pdf: 3757663 bytes, checksum: 66acc24c6f3d11d42e726d1b452899b3 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O sucesso da cerâmica estrutural na maioria das aplicações depende não somente das propriedades do material e do projeto da peça, mas também da qualidade do produto usinado. Um dos fatores citados como obstáculo à ampla utilização das cerâmicas é a falta de confiabilidade dos componentes de cerâmica, em função da grande dispersão dos valores de resistência mecânica provocada por defeitos que podem ter origem no processo de retificação. A retificação de cerâmica, assim como na indústria de processamento metal-mecânica, é realizada normalmente com abundância de fluidos de corte. A utilização destes fluidos refrigerantes resulta em problemas ecológicos, fisiológicos e econômicos. Desde a última década, a opinião pública, o mercado, as leis e regulamentos têm pressionado as indústrias para considerar os riscos ambientais na manufatura. Com o propósito de avaliar alternativas ao método convencional de lubri-refrigeração, foi estudada a viabilidade da técnica de refrigeração otimizada, onde o fluido de corte é aplicado à mesma velocidade periférica do rebolo, penetrando na região de corte com menos turbulência. Também foi analisada a técnica da Mínima Quantidade de Lubrificação (MQL), na qual o grande volume de fluido de corte é substituído por um jato de ar contendo uma quantidade ínfima de lubrificante. Os métodos foram comparados através da análise de desempenho durante o processo de retificação (forças de corte, emissão acústica, energia de retificação) e pela caracterização dos corpos de prova (rugosidade, danos subsuperficiais) e do rebolo (relação G). A profundidade de corte e o efeito do spark-out também formaram parte do escopo deste trabalho. Os resultados obtidos mostraram que a profundidade de corte exerce grande influência durante o processo... / The success of structural ceramics in most applications depends not only on the materials properties and component design, but also the quality of machined products. One factor usually mentioned as a barrier to the wide use of ceramics is the lack of reliability of ceramic components, because the variability on the mechanical strength caused by defects that can be impaired in the grinding process. The grinding of ceramics, as much as with steel grinding is performed generally with excess of cutting fluids (coolants). The use of coolants results in serious ecological, physiological and economic issues. Since last decade the public opinion, the market, the laws and regulations have pushed the industries to consider the environmental risks in the manufacturing process. Then, in order to evaluate alternatives to the conventional method of cooling and lubrication, it was studied the viability of the optimized technique, where the cutting fluid is applied to the same peripherical speed of the wheel, penetrating in the cutting zone with less turbulence. Also, it was verified the technique of Minimum Quantity of Fluid (MQF), where a large amount of cutting fluid is replaced by an air compressed flow containing a small quantity of lubricant. The methods were compared through performance analysis during the grinding process (cutting forces, acoustic emission and specific grinding energy) and by characterization of specimens (roughness, subsurface damage) and wheel (G ratio). The depth of cut and the effect of spark-out were part of the scope of this work too. The results obtained showed that the depth of cut has great influence during the process and in the characterization of ceramics, while spark-out does not seem to be so significant. Another conclusion is that MQF is not viable in ceramics grinding with the working conditions proposed. The results obtained... (Complete abstract, click electronic access below)
169

Modelagem do escoamento e da transferência de calor ao longo de tubos capilares não adiabáticos

Silva, Marcelo Camargo da [UNESP] 23 April 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:38Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-04-23Bitstream added on 2014-06-13T19:29:57Z : No. of bitstreams: 1 silva_mc_me_ilha.pdf: 749066 bytes, checksum: 898e72bcde1702f0b46c2b4a5c84198f (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Neste trabalho, apresenta-se um modelo numérico do escoamento e da transferência de calor, no regime transiente, de fluidos refrigerantes no interior de tubos capilares, largamente usados como dispositivos de expansão em sistemas de refrigeração e condicionamento de ar de pequeno porte. Os tubos capilares aqui analisados formam, em parte de suas extensões, um trocador de calor em contracorrente com a linha de sucção do compressor, conhecido como trocador de calor tubo capilar-linha de sucção. A análise do comportamento dinâmico do escoamento é de fundamental importância, pois os tubos capilares são usados em sistemas de refrigeração, que geralmente são controlados pelo método liga-desliga. Tal escoamento é assumido unidimensional e, dependendo da condição no tempo, é dividido em uma região onde o fluido refrigerante encontra-se no estado de líquido sub-resfriado, outra de escoamento bifásico líquido-vapor e outra de vapor superaquecido. O tubo capilar é considerado reto, horizontal, com diâmetro constante e o fenômeno de metaestabilidade do escoamento é desconsiderado. Implementa-se no modelo o procedimento para a simulação de transientes de partida do sistema. A solução do sistema de equações diferenciais, usando o método de Volumes Finitos, é obtida ao longo do tubo até que a condição de bloqueio seja alcançada, ou até que a pressão de evaporação seja atingida, caso o escoamento não esteja bloqueado. Os resultados obtidos são comparados com os dados experimentais disponíveis na literatura e obtidos a partir de outros modelos / This work presents a numerical model to simulate unsteady flow and heat transfer along nonadiabatic capillary tubes, commonly used as expansion devices in small refrigeration and air conditioning systems. These capillary tubes form with the suction line of the compressor, in part of their extension, a counter flow heat exchanger. Such device is called capillary tubesuction line heat exchanger. Analysis of the flow dynamic behavior is very important, since the capillary tubes are used in refrigeration systems generally controlled by on-off method. The flow along the straight and horizontal capillary tube, with constant inner diameter, is divided, depending of time condition, into three regions: a single-phase flow of subcooled liquid, a two-phase flow region and a single phase of flow superheat. The flow is taken as one-dimensional and the metastable flow phenomenon is neglected. The procedure for simulation of the start-up transient period of the system is implemented in the model. The solution of the governing equations is obtained using the Finite Volume method, along the tube until the blocking condition is reached, or until the evaporation pressure is reached, if the flow is not blocked. The numerical results obtained are compared with the experimental date from the literature and with results obtained from other models
170

Aspectos da furação do titânio 6Al4V com broca de aço rápido sinterizado e broca de metal duro / Drilling aspects from titanium 6Al4V with sintered high speed steel drill and carbide drill

Allegrini, Alex [UNESP] 14 July 2014 (has links) (PDF)
Made available in DSpace on 2015-03-03T11:52:43Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-07-14Bitstream added on 2015-03-03T12:07:08Z : No. of bitstreams: 1 000807370.pdf: 2293849 bytes, checksum: d68b7cab07938392e6c6fbc74359add9 (MD5) / As exigências e a competitividade atual levam, cada vez mais, à busca por soluções mais baratas e eficazes, para qualquer segmento de mercado. Com isso, o ramo aeronáutico tem procurado por ferramentas que possibilitem o mais alto rendimento possível aliado à redução de custos. Este trabalho de furação em placas de titânio 6Al4V tem origem em função da comunalidade de uso deste material nas indústrias, por manter alta resistência mecânica e a altas temperaturas. As ferramentas escolhidas foram brocas de metal duro e brocas de aço rápido sinterizado objetivando um estudo comparativo entre estas, nas mais variadas condições de corte, desde a refrigeração em abundância com utilização de óleo solúvel, passando pela usinagem à seco e finalizando com o sistema da Mínima Quantidade de Lubrificação (MQL) com óleo de corte puro. Os parâmetros de corte adotados foram conforme literatura técnica, para brocas de metal duro, utilizou-se velocidade de corte de 28 m/min, avanço total de 72 m/min e rotação de 2123 RPM e para as brocas de aço rápido sinterizado, velocidade de corte de 11 m/min, avanço total de 29 mm/min e rotação de 876 RPM. Anterior ao inicio dos testes, foi aplicado a ferramenta de Análise do Modo e Efeito de Falha a fim de identificar e prevenir possíveis discrepâncias na execução do processo de furação. A usinagem ocorreu em passes de 8mm de profundidade com interrupção a cada 200mm a 250mm para recolhimento de amostra de cavaco e avaliação parcial dos diversos possíveis desgastes nas ferramentas. Os parâmetros iniciais de finalização de cada broca foram estabelecidos com desgaste de 0,1mm ou tolerância de furos finais acima de H12. Os testes foram repetidos para ambas as brocas sempre em condições idênticas a fim de permitir uma comparação de resultados entre as ferramentas, geração ... (Resumo completo, clicar acesso eletrônico abaixo) / The current requirements and the competitiveness lead, increasingly, to the search for cheaper and more effective solutions, to any segment of the market.Thus the aeronautics the aviation industry has been searching for tools that allow the highest possible income combined with the cost reduction.. This work of drilling in 6Al4V titanium plates originates due to the commonality of use of this material in industries, for maintaining high mechanical strength and high temperatures. The tools chosen were carbide drills and drills of sintered high speed steel aiming at a comparative study between these, in the most varied cutting conditions, since refrigeration in abundance with use of oil soluble, through dry machining and finishing with the system of Minimal Quantity of Lubrication with neat cutting oil. The cutting parameters were adopted as technical literature, for carbide drills, used cutting speed of 28 m/min, total advance of 72 m/min and 2123 RPM rotation and sintered high speed steel drills, cutting speed of 11 m/min, total advance of 29 mm/min and 876 RPM rotation. Prior to the start of the tests, was applied to the analysis tool mode and effect of failure in order to identify and prevent possible discrepancies in the execution of the drilling process. The machining occurred in 8 mm deep steps with interruption every 200 mm to 250 mm for chip sample and partial evaluation of the various possible wear on tools. The initial parameters of completion of each drill were set with 0,1mm wear or tolerance of final holes above H12. The tests were repeated for both drills always in identical terms in order to allow a comparison of results between the tools, chip generation and final diameter. The diameters were measured with standard pins every 20 holes where, even after intense damage, there was no pre-established dimensional limits variation i.e. ... (Complete Abstract click electronic access below)

Page generated in 0.0532 seconds