• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • Tagged with
  • 6
  • 6
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação de uma prancha ortostática para o aluno com paralisia cerebral em situação de atendimento /

Spiller , Marcelo Grandini. January 2012 (has links)
Orientador: Lígia Maria Presumido Braccialli / Banca: Eduardo José Manzini / Banca: Francisco Ricardo Lins Vieira de Melo / Resumo: Dentre os recursos de Tecnologia Assistiva existentes para a adequação postural na posição ortostática, para o aluno com paralisia cerebral que não pode experienciar a postura em pé, está a prancha ortostática. Em um ambiente escolar e terapêutico, foram observadas dificuldades, em posicionar alunos com paralisia cerebral quadriplégica espástica, com um modelo tradicional de prancha existente no mercado. Sendo assim, estes alunos não tinham acesso adequado e não eram incluídos às atividades desenvolvidas naquele ambiente, por falta de um mobiliário de posicionamento adequado. Por isso, foi desenvolvida uma prancha ortostática a fim de favorecer a participação dos alunos nas atividades. O objetivo deste trabalho foi avaliar a efetividade de uso de uma prancha ortostática para o aluno com paralisia cerebral, por meio da opinião de profissionais da educação e da saúde. Os participantes foram quatro profissionais da Educação e da Saúde que atendiam alunos com paralisia cerebral. A coleta de dados foi realizada em duas etapas. Na primeira etapa, foi utilizado um instrumento estruturado com os quatro profissionais que realizaram suas atividades com dois alunos com paralisia cerebral, posicionados na prancha. Os resultados indicaram que o uso da prancha favoreceu o desempenho de habilidades motoras, de comunicação e de participação do aluno A1, porém foi imparcial para seu desempenho de interação. Indicaram também que a prancha não favoreceu os desempenhos de habilidades motoras e de interação da aluna A2, e, para seus desempenhos de comunicação e de participação, foi imparcial. Na segunda etapa, foram realizadas entrevistas semiestruturadas com os participantes. O áudio das entrevistas... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Among the resources available to Assistive Technology in the postural orthostatic position for a student with cerebral palsy who can not experience the orthostatic position, there is available the orthostatic board to help them. In a school and therapeutic environment, difficulties have been reported in positioning students with spastic quadriplegic cerebral palsy with a traditional model of board available on the market is used. So, this being the case, these students did not have access, were not included in some of the activities performed in that environment, for lack of the necessary equipment to help positioning of the students. Consequently an orthostatic board, has been developed, so as to help and enable the students to take part in the activities mentioned. The target of this study was to evaluate the effectiveness of use of an orthostatic board, suitable for the students with cerebral palsy, by means of opinions and suggestions given by the health and education professionals. Those that participated in this work, were four professionals from Education and Health areas, that attend the students with cerebral palsy. Data collection was performed in two steps. In the first step was used a structured instrument by the four professionals, who carried out their activities with two students with cerebral palsy positioned on the board. The results indicated that the use of the board favored the performance of motor skills, communication and participation of the A1 student, but was impartial for his interaction performance. They also indicated that the board did not favor the performance of motor skills and interaction of A2 student... (Complete abstract click electronic access below) / Mestre
2

Abordagem teórica e prática sobre a reabilitação de pacientes portadores de acidente vascular encefálico, e desenvolvimento de um equipamento/protótipo : uma possibilidade inovadora de tratamento /

Ferreira, Karina Alves Candido. January 2009 (has links)
Orientador: João Candido Fernandes / Banca: Paulo Kawauchi / Banca: Abilio Garcia dos Santos Filho / Resumo: Objetivo: apresentar uma proposta de aum produto/equipamento, que represente uma possibilidade de ajuda e benefício ao tratamento e qualificação da intervenção médica aos portadores de acidente vascular encefálico que apresentem como seqüela pequenos graus de força muscular ou que não tenham consciência corporal e ou não respondem a estímulos. Buscando promover uma melhor qualidade de vida para o usuário e para o profissional que irá manipulá-lo. O método para o desenvolvimento do produto foi baseado na suspensoterapia, após sua fabricação foram realizados testes com o produto, e aplicado um questionário aos fisioterapeutas que realizaram os testes. Os exercícios em suspensão demonstraram ser uma alternativa útil em substituição a técnicas tradicionais, sobretudo nos estágios iniciais do tratamento de pacientes portadores de acidente vascular encefálico em que há necessidade de mobilização passiva e ativo-assistida. Com a gravidade e o atrito eliminados, os pacientes conseguiram realizar ou esboçar movimento com maior facilidade, e possibilitando ainda trabalho dos pacientes que não têm consciência corporal ou não respondem a estímulos. No que diz respeito ao tratamento manual e comparando com a utilização do equipamento diminui a apreensão e a fadiga tanto para o paciente quanto para o fisioterapeuta, e demonstrou ser um meio prático e seguro para auxiliar a mobilização precoce. / Abstract: Objectives: This work aims at presenting a proposal of a product/equipment, which represents a possibility of helping and benefiting treatment and qualification of medical intervention on the carriers of encephalic vascular accident who present as sequel small degree of muscular strenghth or who are not conscious of the body and or not respond to stimuli. In order to try to reach a better quality of life to the user and to the professional who is going to handle it. The method of the development of the product was based on the suspention therapy, after its manufacturing tests were made with the product, and a questionnare was applied to the physiotherapists who performed the tests. The exercices in suspension showed to be a useful alternative to the replacement of traditional techniques, especially in the early stages of treatment of the patients carrying encephalic vascular accident in which there is the need of passive mobilization and active assistance. By eliminating gravity and attrition, the patients managed to realize or rough movements more easily and even enabled working on the patients who do not have conscience of the body or do not respond to stimuli. When it comes to the manual treatment in comparasion with the usage of the equipment it reduces the apprehension and fatigue both to the patient and the physiotherapists, and it showed to be a practical and safe means of helping an early mobilization. / Mestre
3

Medição da descarga de peso de indivíduos hemiplégicos e não hemiplégicos utilizando uma nova plataforma de força /

Estremote, Mário Márcio. January 2010 (has links)
Orientador: Aparecido Augusto de Carvalho / Banca: Antônio de Pádua Lima Filho / Banca: Augusto Cesinando de Carvalho / Resumo: Neste trabalho descreve-se um sistema constituído por duas plataformas de forças e seus respectivos circuitos de condicionamento e interfaceamento de sinais, projetado para medir a distribuição de descarga de peso na região plantar de pacientes. Em cada plataforma de força foram acopladas 24 células de carga construídas com extensômetros. As características estáticas do sistema foram determinadas em laboratório utilizando pesos conhecidos. O sistema apresentou linearidade, com coeficiente de determinação de 0,9997, baixa histerese, precisão de 0,84% e resolução de 0,5 N. As medidas são apresentadas na tela de um computador facilitando a visualização para especialistas da área, principalmente médicos, fisioterapeutas e terapeutas ocupacionais. Utilizando o sistema foram medidas as distribuições de peso na região plantar de 87 indivíduos sem hemiplegia (sem histórico de queixas de dores ou problemas no sistema neuromusculoesquelético) e de 10 hemiplégicos crônicos, com mais de um ano de hemiplegia. Estes foram submetidos à avaliação utilizando a Escala de Equilíbrio de Berg. Entre os indivíduos se hemiplegia, estudou-se mais detalhadamente um grupo de 15 bailarinos e um de 12 ginastas rítmicas. Determinou-se a relação entre a distribuição de pesos nos antepés esquerdo e direito de indivíduos sem hemiplegia e hemiplégicos com o sistema implementado. Através do sistema constatou-se que a relação entre a distribuição de pesos no antepé esquerdo e direito dos indivíduos hemiplégicos é muito mais elevada que a dos indivíduos sem hemiplegia. Este resultado era de se esperar, uma vez que o hemiplégico descarrega seu peso predominantemente no lado não plégico / Abstract: This work describes a system consisting of two force platforms and their conditioning circuits and interfacing signals, designed to measure the distribution of weight load on the plantar region of patients. Each force platform was constructed with 24 load cells with strain gages. The static characteristics of the system were determined in laboratory using known weights. The system showed linearity with determination coefficient of 0.9997, low hysteresis, accuracy of 0.84% and resolution of 0.5 N. The measurements are presented in a computer screen in a friend way for specialists in the health field, mainly doctors, physiotherapists and occupational therapists. Using the system we measured the weight distributions in the plantar region of 87 normal patients (no history of complaints of pain or problems in the neuromuscular system) and 10 hemiplegic, with more than a year of hemiplegia. The latter were evaluated using the Berg Balance Scale. Among normal subjects, we studied a further group of 15 dancers and one of 12 rhythmic gymnasts. The relationship between the distribution of weights in the left and right forefeet of patients with normal and hemiplegic was determined with the implemented system. Through the system we found that the relationship between weight distribution on the left and right forefoot of hemiplegic patients is much higher than that of normal patients. This result was expected, since the hemiplegic unloads his weight predominantly in non-paralyzed side / Mestre
4

Análise comparativa de técnicas de moldagem para próteses implantossuportadas /

Amaral, Ângela Líbia Chagas January 2009 (has links)
Orientador: Francisco de Assis Mollo Junior / Banca: João Neudenir Arioli Filho / Banca: Mauro Antônio de Arruda Nóbilo / Resumo: Proposta: A proposta deste estudo in vitro foi avaliar 3 técnicas de moldagem (Cônico, Hélice e Unido com barra) para próteses implantossuportadas. Materiais e métodos: Um modelo mandibular em latão contendo 4 análogos de implantes e uma estrutura metálica foram confeccionados. Foram utilizados 2 materiais de moldagem: Silicona de polimerização por adição (Express STD, 3M ESPE) e Silicona de polimerização por condensação (Zetaplus/Oranwash, Zermack). Seis grupos foram formados pela combinação entre cada material e técnica de moldagem. Um total de 30 modelos foram fabricados (5 modelos por grupo) e 120 valores de fendas foram analisados (1 valor de fenda para cada análogo de implante). Resultados: Para o material Express, os valores médios de fenda foram: 164,40 μm (Cônico), 97,90 μm (Hélice) e 127,79 μm (Unido). Para o material Zetaplus/Oranwash, os valores médios de fenda foram: 219,37 μm (Cônico), 118,57 μm (Hélice) e 78,50 μm (Unido). Houve uma diferença estatística significante entre o Cônico e a Hélice para o material Express (p<.05). Quando o material avaliado foi o Zetaplus/Oranwash, todos os grupos foram diferentes estatisticamente entre si (p<.05). Conclusões: Os melhores resultados foram alcançados para a Hélice e para Unido quando o material avaliado foi o Express. Para o Zetaplus/Oranwash, a melhor técnica foi o Unido, seguida da Hélice e do Cônico. / Abstract: Purpose: The purpose of this in vitro study was to evaluate 3 impression techniques (tapered impression copings, squared modified impression copings, and squared impression copings splinted with bur and acrylic resin) for implant-supported prosthesis. Materials and Methods: A mandibular brass cast with 4 stainless steel implant-abutments analogs and a framework were fabricated. Addition silicone - Express - and condensation silicone - Zetaplus/Oranwash - impression materials were tested. Six groups were formed by combining each material and impression technique. Five casts were made per group for a total of 30 casts and 120 gap values (1 gap value for each implant-abutment analog). Results: With the Express impression material, the mean gap values were 164.40 μm for the tapered group, 97.90 μm for squared modified group and 127.79 μm for squared splinted group. With the Zetaplus/Oranwash impression materials, the mean gap values were 219.37 μm for the tapered group, 118.57 μm for squared modified group and 78.50 μm for squared splinted group. There was significantly difference between tapered impression technique and squared modified impression technique (P<.05), when the material was Express. When the material was the condensation silicone, all groups had significantly difference among themselves (P<.05). Conclusions: The best results were achieved for squared modified impression technique and squared splinted impression techniques, when the impression material was Express. For condensation silicone, the best technique was squared splinted group, followed by squared modified group, and tapered group. / Mestre
5

Comparação de dois sensores de movimento durante a caminhada e atividades cotidianas, em pacientes portadores de doença pulmonar obstrutiva crônica (DPOC) /

Oliveira, Vinícius Cavalheri de. January 2010 (has links)
Orientador: Fábio de Oliveira Pitta / Banca: Ercy Mara Cipulo Ramos / Banca: Simone Dal Corso / Resumo: Comparar a acurácia de dois sensores de movimento (um pedômetro e um multisensor) quanto a contagem de passos e estimativa de gasto energético (GE) em pacientes com doença pulmonar obstrutiva crônica (DPOC) e idosos saudáveis. Neste estudo descritivo, todos os participantes usavam os dois sensores de movimento durante um protocolo de caminhada em esteira, em 3 diferentes velocidades, correspondentes a 30%, 60% e 100% de a velocidade média atingida durante o teste de caminhada de seis minutos. Como métodos critério, o GE foi estimado pela calorimetria indireta, e o número de passos foi registrado por meio de gravação de vídeo ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: To compare the accuracy of 2 motion sensors (a pedometer and a multisensor) in terms of step counting and estimation of energy expenditure (EE) in patients with chronic obstructive pulmonary disease (COPD) and in healthy elderly. In this descriptive study, all participants wore both motion sensors while performing a treadmill walking protocol at 3 different speeds corresponding to 30%, 60%, and 100% of the average speed achieved during a six-minute walk test. As criterion methods, EE was estimated by indirect calorimetry, and steps were registered by videotape ... (Complete abstract click electronic access below) / Mestre
6

Avaliação das propriedades mecânicas e químicas em função de diferentes cimentos resinosos e pinos não-metálicos /

Bandéca, Matheus Coelho. January 2009 (has links)
Resumo: Este estudo objetivou: (1) testar a hipótese que a utilização de pinos nãometálicos em dentes tratados endodonticamente está associado a longevidade da restauração através de uma revisão sistemática; (2) avaliar o grau de conversão de dois cimentos resinosos em diferentes tempos após a fotoativação; (3) avaliar a resistência adesiva de diferentes cimentos resinosos usando dois pinos não-metálicos; (4) e avaliar a resistência a fratura e padrão de falha de dentes submetidos ao clareamento dental interno usando peróxido de hidrogênio a 35% restaurados com diferentes procedimentos. No artigo 1, 157 artigos participaram do estudo e após os critérios de inclusão-exclusão, restaram apenas 5 artigos. Para o artigo 2, vinte espécimes foram confeccionados para cada cimento, Panavia® F2.0 e RelyXTM Unicem Applicap. Cada espécime foi curado com luz LED e foram analisados imediatamente, 24 horas, 48 horas e 7 dias após a fotoativação. Os testes usados foram grau de conversão (FT-IR) e termogravimetria. No artigo 3, oitenta dentes pré-molares unirradiculares livres de coroas foram usados e divididos em 8 grupos: os pinos Exacto! e Everstick! foram cimentados com Breeze!, Nexus! 3, Panavia! e Bistite!. Os dentes foram obturados e preparados para cimentação dos pinos não-metálicos. Cada espécime foi perpendicularmente seccionado em aproximadamente 1 mm de espessura em 6 discos e divididos em região ! cervical, médio e apical. No artigo 4, oitenta dentes incisivos inferiores foram usados e metade foram clareados. Os dentes foram restaurados com resina composta, pinos de resina reforçado com fibra e pinos de fibra de vidro. Os pinos foram cimentados com Breeze! e Panavia!. Os espécimes foram submetidos ao teste de resistência a fratura pela máquina de testes universal. Todos os dados foram submetidos ao devido tratamento estatístico. Os pinos usados... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study aimed: (1) To test the hypothesis that the placement of nonmetallic post in endodontically treated teeth is associated with improved survival rate of the restored teeth althouth systematic review; (2) to evaluate the degree of conversion of two resin cements in differents times after light-activated; (3) to evaluate the microtensile bond strength of different resin cement systems using two nonmetallic posts; (4) to evaluate the fracture resistance and failure pattern of endodontically treated teeth after intracoronal bleaching using 35% hydrogen peroxide with different restorative procedures. For the article 1, 157 papers were used and after the inclusion-exclusion procedure, only 5 papers remained. For the article 2, twenty specimens were made for each cement, Panavia® F2.0 and RelyXTM Unicem Applicap. Each specimen were cured with LED and were tested immediately, 24 hours, 48 hours and 7 days after light-activated. The tests used were degree of conversion (FT-IR) and thermogravimetric. For the article 3, eighty single-rooted human mandibular first premolar free crown were used and divided into 8 groups: Exacto! and Everstick! posts were cemented with Breeze!, Nexus! 3, Panavia! F 2.0 and Bistite! II DC. The teeth were obtured and prepared for cementation of the nonmetallic posts. Each specimen were perpendicularly sectioned into approximately 1 mm thick sections resulting in 6 serial slices and divided in cervical, meddium and apical region. For the !article 4, eighty mandibular incisors were used and the half teeth were bleached. The teeth were restored with composite resin, fiber-reinforced composite post and glass fiber post. The posts were cemented with Breeze! and Panavia!. The specimens were submitted to the fracture resistance test by universal test machine. Statistical analyses were performed for each article. The posts used... (Complete abstract click electronic access below) / Orientador: Sizenando de Toledo Porto Neto / Coorientador: Omar El-Mowafy / Coorientador: Alessandra Nara de Souza Rastelli / Banca: Roberto Cury Saad / Banca: Darlon Martins Lima / Mestre

Page generated in 0.1146 seconds