• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 172
  • 6
  • 6
  • 6
  • 5
  • 3
  • 3
  • 2
  • 1
  • Tagged with
  • 175
  • 93
  • 43
  • 33
  • 31
  • 28
  • 27
  • 25
  • 25
  • 20
  • 20
  • 18
  • 18
  • 18
  • 17
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Avaliação da qualidade da água subterrânea em área de mineração de caulim: impactos e perspectivas de remediação, município de Mogi das Cruzes, SP / Groundwater quality assessment in a kaolin mining area: environmental impacts and remediation prospects, Mogi das Cruzes county, SP

Terrell, Deborah 17 October 2007 (has links)
A presente pesquisa teve como objetivo avaliar a qualidade das águas subterrâneas em área de mineração de caulim, no município de Mogi das Cruzes/SP. A área está inserida na Área de Proteção de Manancial da Região Metropolitana de São Paulo e, conforme o histórico pesquisado, apresentava anomalias geoquímicas associadas aos elementos alumínio, ferro, manganês, zinco e sulfato. Para a execução da pesquisa os trabalhos desenvolvidos foram divididos em: (a) revisão bibliográfica dos temas de interesse para a pesquisa e para caracterização da área de estudo; (b) caracterização hidrogeológica e hidrogeoquímica de suas águas subterrâneas e caracterização hidroquímica das águas superficiais; (c) consulta de todos os relatórios disponíveis a fim de estabelecer um perfil da evolução dos elementos que apresentavam anomalias para o monitoramento até novembro de 2005; e por fim, (d) avaliação e interpretação dos resultados propriamente ditos. Os resultados indicaram que a disposição inadequada dos rejeitos produzidos no processo industrial acarretou na contaminação das águas subterrâneas do local e nas águas das lagoas artificiais, em relação ao sulfato e zinco. Em relação às anomalias de alumínio, ferro e manganês é possível serem inerentes à área. No entanto, a produção e descarte dos efluentes ácidos favorecem o desprendimento dos íons livres encontrados nas águas subterrâneas. Foi possível obter um quadro geral da situação ambiental da área e sugerir perspectivas de recuperação e remediação a partir das principais características encontradas. Dentre as alternativas que melhor se aplicam ao caso, e que mostraram bons resultados em casos similares, são sugeridas as técnicas de reflorestamento a partir de sistemas agro-florestais, a utilização da fitorremediação para a remoção de metais, a ampliação da estação de tratamento de efluentes industriais e uma efetiva correção do pH das águas do processo e das lagoas existentes. / The objective of this research was to evaluate the quality of groundwater in a kaolin mining in the municipality of Mogi das Cruzes/SP. The mining is inserted in the Water Catchment Protection Area of the Metropolitan Region of São Paulo and according to past descriptions, presented geochemical anomalies associated with aluminum, iron, manganese, zinc and sulphate. The work was planned as follows: (a) literature review and characterization of the study area; (b) hydrogeology and hydrogeochemical characterization of groundwater and hydrochemical characterization of superficial waters; (c) reading of all the available analysis reports in order to establish a profile of the variation of the elements that presented anomalies for monitoring until november of 2005 and (d) analysis and interpretation of the results. The results indicated that an inadequate disposal of the waste produced in the industrial process caused the contamination, by sulphate and zinc, of the groundwater and of the waters of the artificial lagoons. As related to anomalies by aluminum, iron and manganese there are evidences that these elements are inherent to the area, but the production and disposal of acid effluents may be associated with the liberation of free ions found in groundwater. It was possible to get a general picture of the environmental characteristics of the area as well as to suggest alternatives for the recovery and remediation, based on the main characteristics observed. Amongst the most suitable alternatives to the case, which showed good results on similar cases the following are suggested: reforestation techniques based on agro-forestry systems; use of phytoremediation for metal removal; improvement of the industrial effluent treatment station and an effective correction of the pH of the superficial waters from the lagoons.
52

Avaliação da eficiência de uma zona alagadiça (wetland) no controle da poluição por metais pesados: o caso da Plumbum em Santo Amaro da Purificação/BA. / Investigation on the wetland efficiency for the control pollution of heavy metals: the specific case of "Plumbum" at Santo Amaro da Purificação/Bahia.

Anjos, José Ângelo Sebastião Araujo dos 24 February 2003 (has links)
Esta pesquisa teve o objetivo de avaliar a eficiência de uma zona alagadiça (wertland) que ocorre nas dependências de uma usina situada em Santo Amaro da Purificação, Bahia, como medida de controle da contaminação proveniente de um barramento de escória contaminada por metais pesados. Inicialmente, foi proposto um levantamento anual com amostragens semanais das águas pluviais e superficiais da zona alagadiça, com o intuito de avaliar a eficiência da zona alagadiça, por meio do levantamento das concentrações dos metais oriundos dos processos de lixiviação e/ou solubilização da escória nos seus pontos de entrada e saída do sistema alagado e, concentrações e potencial disponibilidade dos metais retidos nos sedimentos da zona alagadiça. Foram selecionados os seguintes parâmetros: para as águas pluviais o pH e o volume da chuva; para as águas superficiais as concentrações dos metais Chumbo (Pb), Cádmio (Cd), Zinco (Zn), Cobre (Cu), Alumínio (Al), Manganês (Mn), Ferro (Fe), Magnésio (Mg) e Cálcio (Ca) e os parâmetros de suporte pH, Eh, condutividade, Oxigênio Dissolvido (OD) e temperatura. Para o solo e sedimento da zona alagadiça as concentrações dos metais Pb, Cd, Zn e Cu e, determinação por análise por extração seqüencial do total removido pelo sistema nas suas diversas fases e a potencial disponibilidade dos metais pesados. Todavia, uma modificação da estratégia de pesquisa teve que ser feita em função de uma decisão judicial que determinou o recobrimento da escória e do ponto de entrada da zona alagadiça. Em função do ocorrido, a pesquisa foi dividida em três etapas considerando os levantamentos efetuados antes, durante e depois do recobrimento. Os dados levantados nos cinco meses antes do recobrimento mostraram que os metais cádmio, chumbo, cobre e zinco estão sendo retidos pela zona alagadiça e, que este sistema foi eficiência de 100% para os metais cobre e zinco, 82% para o chumbo e 73% para o cádmio. Os parâmetros de suporte que influenciam a remoção destes metais foram o pH, entre neutro a alcalino, e Eh, na faixa de oxidação das águas superficiais, além da alta capacidade de troca catiônica da montmorilonita presente no sedimento. Quanto ao potencial de disponibilidade dos metais, cádmio, chumbo e zinco apresentam valores elevados, enquanto o cobre encontra-se preferencialmente concentrado na fase residual. A segunda etapa do levantamento realizada durante o recobrimento da escória demonstrou que ocorreu pouca migração dos metais da zona alagadiça, embora a empresa não tenha obedecido as normas técnicas para o recobrimento da escória. Na terceira etapa foi realizado levantamento na saída da zona alagadiça e da drenagem próxima ao rio Subaé. As análises levantadas demonstraram a grande disponibilidade do cádmio no sistema alagado, este mecanismo foi acionado a partir da erosão do solo contaminado disposto sobre a escória e a grande solubilidade do cádmio. Desta forma pode-se conclui que as zonas alagadiças estão sendo eficientes na retenção dos metais. A redução de sua área é indesejável, pois tende a diminuir sua eficiência, como sistema de controle da poluição das águas superficiais, recomenda-se a construção de nova zona alagadiça a jusante da existem. / A lead ore smaller which operated from 1960 to 1993 in Santo Amaro da Purificação, Bahia State, disposed of 490,000 tons of slag in a landfill situated in the situated in the industrial site. Earthworks formed a man-made wetland downstream of the slag landfill, which acted as a metal retaining systems, thus preventing further water pollution. This research aimed at investigating the efficiency of this wetland as a water pollution control system. The research plan scheduled weekly samplings of rainfall, rainwater pH and water runoff in two points corresponding to the input and the output of the wetland for determination of metals concentration (Pb, Cd, Cu, Zn, Al, Mn, Fe, Mg, Ca), as well as water pH, Eh, conductivity, temperature and dissolved oxygen (OD). In addition, soil and sediment in the wetland were sampled and analyzed for Pb, Cd, Zn and Cu by sequential extraction methods. However, a Court ruling following a lawsuit for environmental damage led to the slag being covered by clayish soil weeks after sampling began. As a consequence, the point where waters entered the wetlands has been covered. Hence, sampling in this point has been discontinued and a new sampling point was established downstream of the wetland, at a point where its waters flow into a river. Results showed that before cover-up, Pb, Cd, Cu and Zn were being retained in the wetland at rates reaching 100% for Cu and Zn, 82% for Pb and 73% for Cd. After cover-up, Cd was being released into the waters. Sequential extraction showed that only Cu is not available for leaching, since it is mostly concentrated in the insoluble phase. On the other hand, Pb, Cd and Zn are potentially available, thus could re-enter other media if wetland is disturbed. The wetland acts as an efficient device for retaining metals because of near neutral water pH, oxidizing water Eh, and the existence of montmorillonite clay in the sediments, which features high cationic exchange capacity. It is concluded that this involuntary wetland has been working, as an efficient system for water pollution control. The reduction in its size, due to the cover-up activities, is undesirable. Hence, a new constructed wetland is proposed downstream of the existing one. Then, we can end that the wetland of Plumbum this being efficient in the control of the metals, from when interferences anthropogenetic that maximize the capacity of support of this system don’t happen.
53

Estudo da contaminação por metais na Bacia do Rio Ribeira de Iguape (SP-PR): estratégias para a remediação da área de disposição de rejeitos da Mina do Rocha / Study of the contamination by metals in Rio Ribeira de Iguape basin (SP-PR): strategies for the remediation of an area of waste disposal of Rocha Mine

Cassiano, Andréia Márcia 12 November 2001 (has links)
O principal objetivo do presente trabalho foi o de propor estratégias para a remediação de uma das áreas fontes de contaminação por metais na Bacia do Rio Ribeira de Iguape. Assim, inicialmente foi efetuado um diagnóstico da contaminação na área de estudos que possibilitou a elaboracão de uma análise espaço-temporal da contaminação por metais na bacia e a identificação das atuais fontes desses elementos para os ecossistemas naturais. A partir da escolha de uma destas fontes, qual seja a área de disposição de rejeitos de mineração de chumbo-prata (Pb-Ag) da Mina do Rocha, foram feitas caracterizações químicas, mineralógicas e toxicológicas (bioensaios) dos resíduos e conduzidos experimentos em microcosmos que buscaram simular tanto a permanência destes rejeitos em pilhas quanto a sua inundação, já que existe uma proposta de implantação de uma represa no local para geração de energia (Usina Hidrelétrica do Tijuco Alto). O trabalho conclui que a forma de disposição atual das pilhas é totalmente inadequada e que a submersão dos rejeitos também é desaconselhada, pois propiciaria a liberação de metais para a água e colocaria em risco a sobrevivência de organismos planctônicos de água doce que constituem a base da cadeia alimentar deste ecossistema. A alternativa proposta pelo presente trabalho sugere a retirada dos rejeitos do local e sua disposição de maneira que permaneçam insaturados e protegidos da ação de processos erosivos. Uma possível alternativa seria a colocação do material no interior das galerias subterrâneas da Mina do Rocha. No entanto, a implantação desta medida exigiria um estudo detalhado a respeito da influência do lençol freático ou de outros dutos d\'água no local. Outras alternativas consideradas adequadas envolvem a utilização de técnicas de estabilização/solidificação e disposição em aterros de resíduos perigosos de acordo com as normas e exigências legislativas existentes. / The aim of the present work was to propose strategies for the remediation of one of the contamination sources by metals in the Rio Ribeira de Iguape Basin. Initially a diagnosis of the contamination was made in the study area, which allowed for a space-temporal analysis of the contamination by metals in the basin and the identification of the present sources of such elements for natural ecosystems. The lead-silver waste disposal site of Rocha Mine was chosen as a test area for the suggestion of remediation strategies, where chemical, mineralogical, and toxicological (bio-essays) characterization ofthe wastes were carried out. Experiments were conducted in order to simulate the stability of the wastes in piles and their immersion, since there is project of the construction of a dam for energy generation in this place (Usina Hidréletrica de Tijuco Alto). The study concluded that the present localization of the waste piles is inadequate and their submersion is also inadvisable, propitiating the liberation of metals to the water and threatening the survival of plankton organisms in the water. The alternative proposed in the present work suggests the removal of the waste from the area and their proper disposal so that they remained unsaturated and protected from erosive processes. A possible alternative is to locate them within the subterranean galleries of the Rocha Mine. Other alternatives proposed involve stabilization/solidification techniques and disposal of dangerous wastes in landfills according to the norms and requirements of related legislation.
54

Desenvolvimento de um dispositivo para avaliação do transporte de combustíveis no meio subterrâneo. / Development of a device for evaluating fuel transport in the underground soil.

Toledo, Manoel Paulo de 13 November 2012 (has links)
O presente trabalho teve o intuito de desenvolver um novo dispositivo para melhor conhecer a movimentação de combustíveis no meio subterrâneo, fundamental à definição de tecnologias para remediação de áreas contaminadas. Paralelamente, procurou-se verificar a viabilidade da utilização do dispositivo proposto como método simples, rápido e de baixo custo para investigação do fluxo do óleo diesel, da gasolina e do biodiesel no solo. Fabricou-se um microcanal em poli(dimetil)siloxano que reproduziu fielmente as dimensões e geometrias dos poros e canais do solo. Inicialmente, o microcanal foi saturado com ar; em seguida, injetou-se o combustível e sequencialmente, a água de tal forma a simular um derramamento de combustível no solo sucedido por uma precipitação. Cada operação foi gravada em vídeo ou fotografada, o que permitiu a visualização dos fenômenos que ocorriam no interior do canal. Os resultados obtidos mostraram a viabilidade do dispositivo proposto para o estudo da movimentação dos combustíveis no meio subterrâneo. Verificou-se que tanto a gasolina quanto o óleo diesel evaporam, sendo a primeira mais rapidamente do que o segundo. O experimento permitiu calcular a taxa de evaporação de gasolina no solo. O óleo diesel e o biodiesel ficaram retidos nos poros fechados e a eventual água da chuva que escoava pelo mesmo caminho que a fase gasosa (ar e no caso do óleo diesel, vapores) removia parcialmente esses combustíveis. / The present work had the aim of developing a new device for better understanding fuel motion in the underground soil a key issue for the definition of contaminated area remediation technologies. As a side goal one tried to verify the feasibility of using the proposed device as a simple, fast and inexpensive tool for the investigation of underground fuel flow in porous soil by means of laboratory experiments with it. A poly(dimethyl)siloxane microchannel reproducing exactly the dimensions and geometries of soil pores and channels has been fabricated. Initially the microchannel was saturated with air; then firstly fuel was injected and sequentially water in order to mimic soil contamination by fuel leakage followed by a rain fall. Each and every operation was video recorded or photographed what allowed the visualization of the phenomena occurring inside the microchannel. Results showed the viability of the proposed device for studying the transport of fuels in the underground soil. It has been verified that gasoline vaporizes as does diesel oil as well, the former quicker than the last. The experiment allowed calculating the evaporation rate of gasoline in the soil. It has been seen that diesel oil and biodiesel remained trapped in closed pores and the eventual rain water flowed through the gaseous phase way (air and in the case of diesel oil, vapor) partially removing them.
55

Caracterização da comunidade bacteriana em água subterrânea contaminada com tetracloroeteno / Characterization of the bacterial community in groundwater contaminated with tetrachloroethene

Armas, Rafael Dutra de 30 January 2008 (has links)
Dentre os contaminantes de água subterrânea de maior importância está o tetracloroeteno (PCE), o qual é altamente tóxico e potencialmente carcinógeno. As comunidades bacterianas de águas subterrâneas contaminadas com PCE e a diversidade de bactérias capazes de degradar esses organoclorados são pouco conhecidas. O objetivo deste trabalho é comparar a estrutura das comunidades de bactérias de amostras de água subterrânea em uma área contaminada com PCE e selecionar um consórcio microbiano capaz de degradar eficientemente o PCE em reator horizontal de leito fixo (RHLF). Amostras de água subterrânea de oito poços de monitoramento, instalados em uma área contaminada com PCE foram coletadas e analisadas para determinação de oxigênio dissolvido, potencial redox, condutividade elétrica, pH e concentração de tetracloroeteno, tricloroeteno, cis-dicloroeteno e cloreto de vinila (COVs). As amostras foram analisadas também para a determinação da estrutura das comunidades de bactéria por PCRDGGE e seqüenciamento de clones do gene rRNA 16S. Os parâmetros físico-químicos oscilaram consideravelmente ao longo do tempo em todos os poços de monitoramento (PM). Tetracloroeteno e tricloroeteno foram detectados apenas no PM6. As estruturas das comunidades bacterianas dos PMs analisados mostraram tanto variação temporal quanto espacial. As análises das comunidades bacterianas nos PM6 e PM8, contaminado e não-contaminado com PCE, revelaram resultados semelhantes aos obtidos por DGGE. Uma maior riqueza estimada de espécies bacterianas foi observada nas amostras do PM8, pelo menos em duas épocas de amostragem, sugerindo que a contaminação com PCE está associada com a redução da diversidade bacteriana em água subterrânea. Cultivos de enriquecimento e ensaios de degradação do PCE foram realizados utilizando-se um RHLF, o qual foi preenchido com sedimento do PM6 imobilizado em espuma de poliuretano e enriquecido com meio mineral básico suplementado com PCE. A análise das alterações nas comunidades de bactérias nos reatores foi feita por PCRDGGE e seqüenciamento parcial do gene rRNA 16S. No ensaio de degradação do PCE no RHLF foi utilizado meio com PCE suplementado ou não com lactato e acetato. Tanto pelo DGGE quanto pelo seqüenciamento, foi observada a seleção de bactérias específicas no reator. A partir das análises de seqüenciamento, essas bactérias foram identificadas como Alphaproteobacteria e Sphingobacteria. No ensaio de degradação do PCE, os parâmetros físico-químicos do meio não mostraram variações ao longo do comprimento dos reatores. As análises de COVs mostraram uma grande eficiência na degradação do PCE (98%), com um tempo de retenção de 12 horas, não havendo diferença significativa na percentagem de degradação em meio com lactato ou acetato, com relação ao controle sem fonte de carbono. No processo de degradação nenhum dos produtos da via de degradação do PCE foi detectado, o que sugere uma via alternativa de degradação do PCE, a qual ocorre em aerobiose. / Tetrachloroethene (PCE) is one of the most important contaminants of groundwater, since it is highly toxic and potentially carcinogenic. The bacterial communities of PCE contaminated groundwater and the diversity of bacteria capable of degrading this contaminant are barely known. The objective of this work is to compare the structure of bacterial communities from groundwater samples from a PCE contaminated site and select a microbial consortium capable to degrading efficiently PCE in a horizontal fixed bed reactor (HFBR). Groundwater samples from eight monitoring wells, installed in a PCE contaminated site were collected and analyzed for determination of dissolved oxygen, redox potential, electrical conductivity, pH, and concentrations of tetrachloroethene, trichloroethene (TCE), cis- and trans-dichloroethene, vinyl chloride (VOCs). The structure of the bacterial communities was determined by PCR-DGGE and 16S rRNA gene clone sequencing. The physical-chemical parameters oscillated considerately throughout time in all the monitoring wells (MW). PCE and TCE were detected only in MW6. The bacterial community structures in the groundwater from the MWs analyzed showed temporal and spatial variation. The analysis of the bacterial communities in MW6 and MW8, contaminated and non-contaminated with PCE, respectively, based on sequencing of 16S rRNA gene clones revealed results to the ones observed by DGGE. Estimated richness of bacterial species was higher in samples from MW8, at least in two sampling times, suggesting that the contamination with PCE is associated with reduction of bacterial diversity in groundwater. Enrichment cultures and PCE biodegradation assays were performed in a HFBR, which was filled with sediment from MW6 immobilized onto polyurethane foam and enriched with basic mineral medium supplemented with PCE. Shifts in bacterial community structure were analyzed using PCRDGGE and partial sequencing of 16S rRNA gene clones. In the PCE biodegradation assays in the HFBR, were performed in medium containing lactate or acetate. DGGE and 16S rRNA gene clone sequencing data suggest selection of specific bacteria in the reactor. Sequencing data showed that these bacteria belong to Alphaproteobacteria and Sphingobacteria. In the PCE biodegradation assays, media physical-chemical parameters did not show variation along the reactor length. VOC analyses showed a great efficiency in the degradation of PCE (98%) with a residence time of 12 hours in the reactor, and no significant differences were observed in the presence of lactate or acetate, as compared to the medium without a carbon source. During the biodegradation process, none of the products from the anaerobic pathway of PCE reductive dechlorination was detected, suggesting that an alternative PCE biodegradation pathway is occurring in aerobiosis.
56

Tratamento de solos contaminados com bifenilas policloradas (PCBs). / Contaminated soils treatment with polychlorinated biphenyls (PCBs).

Policarpo, Nara Angélica 30 April 2008 (has links)
Devido à alta toxicidade, a produção e comercialização dos PCBs (Polychlorinated Biphenyls - Bifenilas Policloradas) estão proibidas no mundo todo. Esses compostos foram utilizados principalmente como base de misturas comerciais em óleos dielétricos para transformadores e capacitores. Hoje existem diversas áreas contaminadas com essas substâncias que são de difícil degradação ocasionada pela sua elevada estabilidade térmica e química. Há diversos estudos sobre diferentes técnicas de tratamento de áreas contaminadas por PCBs. A técnica proposta nesse trabalho foi a de oxidação química através do reagente de Fenton. Para isso, foi simulado em laboratório experimentos de tratamento de solo contaminados artificialmente por ascarel (mistura comercial de PCBs). A oxidação foi realizada segundo a técnica do planejamento experimental fatorial de dois níveis e duas variáveis. Manteve-se constante a concentração do contaminante - em torno de 6000 mg de PCB/ kg de solo - e variou-se a concentração de Fe2+ (0,04 a 0,1 mol/L) e H2O2 (2,07 a 4,15 mol/L). Os ensaios foram realizados ainda nos seguintes tempos de reação: 0, 5, 24 e 48 horas. A análise dos dados foi realizada através de cromatografia gasosa acoplada a um espectrômetro de massa - GC/MS. Dos resultados, concluiu-se que o experimento cuja concentração do reagente de Fenton era 4,15 mol/L de H2O2 e 0,04 mol/L de Fe2+, apresentou melhor percentual de remoção, em torno de 76% para o pentaclorobifenila, 67% para o hexaclorobifenila e 72% para o heptaclorobifenila. Além disso, observou-se que, dentro da região experimental estudada, o efeito da concentração de íons ferrosos foi mais significativo do que o causado pela concentração de peróxido de hidrogênio e que o mesmo tem um efeito negativo pois aumentando a concentração dos íons ferrosos diminui-se a remoção dos contaminantes. / Production and trading of polychlorinated biphenyls (PCBs) are prohibited at whole world due to their high toxicity. They were used mainly as dielectric oils for transformers and capacitors. Recently there are many contaminated areas with these compounds. The high thermic and chemistry stability of PCBs are responsible for their hard degradation. Many studies have been conducted about several techniques of soil remediation. The main purpose of this research is to study chemical oxidation using Fenton\'s reagent to soils treatment. It was simulated in laboratory experiments of soil treatment which was artificially contaminated with Ascarel (PCBs commercial mixture). Process oxidation was made according to factorial experimental planning technique of two levels and two variables (22). The contaminant concentration was constant - 6000 mg PCB/ kg soil - and it was varied the Fe2+ concentration (0,04 mol/L to 0,10 mol/L) and H2O2 concentration (2,07 mol/L to 4,15 mol/L). The times reaction of experiments were: 0, 5, 24 and 48 hours. It was used gas chromatography coupled with mass spectrometer - GC/MS. The better result shown removal rate of 76% to pentachlorobiphenyl, 67% to hexachlorobiphenyl and 72% to heptachlorobiphenyl, experimental conditions were Fe2+ concentration of 0,04 mol/L and H2O2 concentration of 4,15 mol/L. Besides it was observed that studied region the concentration effect of ferrous ions was more significant than concentration effect of hydrogen peroxide. The concentration effect of ferrous ions was negative on system because removal rate of contaminants decreases when [Fe2+] increases.
57

Remediação eletrocinética - novas técnicas / not available

Sumi, Ernesto Massayoshi 10 March 2017 (has links)
O impacto ambiental causado por íons de metais pesados e compostos orgânicos iônicos tem forçado o aperfeiçoamento dos processos de remediação já existentes e mesmo a busca de novas técnicas. A maioria das atuais técnicas apresenta limitações especialmente para águas associadas a solos de baixa permeabilidade hidrodinâmica e para as aplicações in situ que são de menor custo. A eletrorremediação é uma técnica que se baseia na aplicação de uma corrente elétrica de baixa intensidade entre dois ou mais eletrodos em poços escavados no solo e vem de encontro com esses objetivos. Procurando contribuir para a melhoria dessas técnicas, neste trabalho foram estudados experimentalmente os principais parâmetros que envolvem a remediação eletrocinética e sua aplicação em campo. Nesses experimentos foram empregados como substrato areia, caulim, solo natural não contaminado e solo natural contaminado. Como representante dos íons de metais pesados utilizaram-se soluções de sulfato de cobre. O meio ácido se mostrou mais eficiente e foi obtido com uma solução de 5% de ácido acético. Os eletrodos que apresentaram melhores resultados foram aqueles com maior superfície útil (tela de aço) e que foram montados o mais próximo possível um do outro, não se tocando. Também foi estudada a evolução do cobre (II) em relação ao pH e Eh em função do tempo e tratou-se ainda de sua distribuição no interior das células eletrocinéticas após aplicação de eletricidade. Esses estudos culminaram no desenvolvimento de uma nova técnica que se mostrou bastante eficiente aplicada na eliminação de íons cobre em uma área contaminada na Região Metropolitana de São Paulo. Essa técnica, consiste em montar em um único poço, um sistema constituído por um par de eletrodos metálicos, ligados a uma fonte de energia que fornece corrente contínua. / The environmental impact caused by heavy metal ions and organic ionic compounds forced the improvement of remediation processes and the search for new techniques. The current techniques of remediation present limitations, especially for waters associated with low-hydrodynamic permeability soil and in situ applications that have lower cost. The electroremediation is a technique that is based on the application of a low intensity electric current between two or more electrodes in wells excavated in the soil. In order to contribute to the improvement of these techniques the main parameters involving electrokinetic remediation and it´s application on the field were studied in this research. The substrates used for the experiments were: sand, kaolin, uncontaminated natural soil and contaminated natural soil. As representative of heavy metal ions, copper sulphate solutions were used. The acid solutions was proved to be the most effective, and was obtained with a 5% acetic acid solution. The electrodes that presented the best results were those with the largest useful surface (steel mesh) and were set as close as possible from each other without direct contact. The evolution of copper (II) in relation to pH and Eh according to time was also studied, and its distribution within the electrokinetic cells were studied after the application of electricity. These studies culminated in the development of a new technique that proved to be very effective in the elimination of copper ions in a contaminated area in a Metropolitan Region of São Paulo. This technique consists in inserting a system, on a single well, constituted by a pair of metal electrodes connected to an energy source that provides direct current.
58

Avaliação da interação entre o persulfato de potássio com solos brasileiros para a utilização da tecnologia de remediação por oxidação química in situ. / Evaluation of interaction between potassium persulfate and Brazilian soils for use in remediation technology by in situ chemical oxidation.

Oliveira, Fernanda Campos de 19 May 2015 (has links)
Recentemente, o uso de persulfato em processo de oxidação química in situ em áreas contaminadas por compostos orgânicos ganhou notoriedade. Contudo, a matriz sólida do solo pode interagir com o persulfato, favorecendo a formação de radicais livres, evitando o acesso do oxidante até o contaminante devido a oxidação de compostos reduzidos presentes no solo ou ainda pela alteração das propriedades hidráulicas do solo. Essa pesquisa teve como objetivos avaliar se as interações entre a solução de persulfato com três solos brasileiros poderiam eventualmente interferir sua capacidade de oxidação bem como se a interação entre eles poderia alterar as propriedades hidráulicas do solo. Para isso, foram realizados ensaios de oxidação do Latossolo Vermelho (LV), Latossolo Vermelho Amarelo (LVA) e Neossolo Quartzarênico (NQ) com solução de persulfato (1g/L e 14g/L) por meio de ensaios de batelada, bem como a oxidação do LV por solução de persulfato (9g/L e 14g/L) em colunas indeformadas. Os resultados mostraram que o decaimento do persulfato seguiu modelo de primeira ordem e o consumo do oxidante não foi finito. A maior constante da taxa de reação (kobs) foi observada para o reator com LV. Essa maior interação foi decorrente da diferença na composição mineralógica e área específica. A caulinita, a gibbsita e os óxidos de ferro apresentaram maior interação com o persulfato. A redução do pH da solução dos reatores causou a lixiviação do alumínio e do ferro devido a dissolução dos minerais. O ferro mobilizado pode ter participado como catalisador da reação, favorecendo a formação de radicais livres, mas foi o principal responsável pelo consumo do oxidante. Parte do ferro oxidado pode ter sido precipitado como óxido cristalino favorecendo a obstrução dos poros. Devido à maior relação entre massa de persulfato e massa de solo, a constante kobs obtida no ensaio com coluna foi 23 vezes maior do que a obtida no ensaio de batelada, mesmo utilizando concentração 1,5 vezes menor no ensaio com coluna. Houve redução na condutividade hidráulica do solo e o fluxo da água mostrou-se heterogêneo após a oxidação devido a mudanças na estrutura dos minerais. Para a remediação de áreas com predomínio de solos tropicais, especialmente do LV, pode ocorrer a formação de radicais livres, mas pode haver um consumo acentuado e não finito do oxidante. Verifica-se que o pH da solução não deve ser inferior a 5 afim de evitar a mobilização de metais para a água subterrânea e eventual obstrução dos poros por meio da desagregação dos grãos de argila. / Recently the persulfate application for in situ chemical oxidation at areas contaminated by organic compounds gained notoriety. However, the persulfate can interact with the solid matrix of the soil favoring the formation of free radicals, avoiding the oxidant access to the contaminant due to the oxidation of reduced compounds present in the soil or by changing the hydraulic properties of the soil. This research aimed to evaluate if the interactions between the persulfate solutions and three Brazilian tropical soils could eventually interfere on the persulfate oxidation capacity and if the interaction between them could modify the hydraulic properties of the soil. For such, oxidation tests were performed with soils: Latossolo Vermelho (LV), Latossolo Vermelho Amarelo (LVA) and Neossolo Quartzarênico (NQ) with persulfate solution (1 and 14 g/L) through batch tests and LV oxidation by persulfate solution (9 and 14 g/L) on undisturbed columns. The results showed that persulfate decay followed a first order model and oxidant consumption was not finite. The higher reaction rate coefficient (kobs) was observed in the reactor with LV. This higher interaction was due to the difference in the mineralogical composition and surface area. Kaolinite, gibbisita and iron oxides showed greater interaction with persulfate. The pH reduction on the reactor solution caused the aluminum and iron leaching due to dissolution of minerals. The mobilized iron may have participated as a reaction catalyst favoring the formation of free radicals although it was the major responsible for the oxidant consumption. Part of oxidized iron may have been precipitated as crystalline oxide favoring the clogged pores. As a consequence of the higher mass proportion between persulfate and soil, the kobs constant obtained in the column test was 23 times higher than the one observed on the batch test, even utilizing a concentration 1.5 times lower than bath test. There was a reduction in the soil hydraulic conductivity and the water flow proved to be heterogeneous after oxidation due to changes in minerals structure. For remediation purposes in areas with predominance of tropical soils, especially LV, the formation of free radicals may occur but an accented and not finite oxidant consumption may happen. It is verified that the pH solution should not be inferior than 5 to prevent the mobilization of metals to the groundwater and a possible pores clogging by the breakdown of the clay grains.
59

Injeção de ozônio em solo proveniente de área contaminada por compostos orgânicos - comportamento de íons metálicos de interesse / Ozone injection into the soil from the area contaminated by organic compounds - behavior of metal ions of interest.

Gardinali Junior, Mauricio 19 November 2013 (has links)
A utilização de ozônio como agente oxidante tem apresentado resultados positivos para a degradação de contaminantes orgânicos em subsuperfície. O ozônio apresenta alta reatividade, tanto com os compostos orgânicos de interesse quanto com os compostos inorgânicos presentes no meio, principalmente com os íons metálicos constituintes da matriz sólida, mobilizando os para a água subterrânea. Este estudo detectou e quantificou os íons metálicos de interesse presentes na matriz solida, sendo estes: Fe, Al, Mn, Cr, Pb, Ni e Zn. Também foram determinados os íons que foram mobilizados da matriz sólida, a partir da injeção do ozônio em solo proveniente de uma área contaminada por compostos orgânicos. / The use of ozone as an oxidizing agent has shown positive results for the degradation of organic contaminants in the subsurface. Ozone is highly reactive with both the organic compounds of interest as with inorganic compounds present in the environment, especially with the metal ions of the solid matrix constituents, mobilizing them into groundwater. This study detected and quantified the metal ions of interest present in the solid matrix, namely: Fe, Al, Mn, Cr, Pb, Ni and Zn. lons that have been mobilized from the solid matrix due to the ozone injection in soil from a contaminated area for organic compounds were also determined.
60

Análise ambiental de solos e águas subterrâneas contaminadas com gasolina: estudo de caso no município de Guarulhos - SP. / Environmental analysis of soils and ground water contaminated with gas: study case in the municipality of Guarulhos - SP.

Trovão, Renata Silva 08 December 2006 (has links)
A Resolução do Conselho Nacional do Meio Ambiente - CONAMA n° 273 evidenciou o problema do vazamento de combustível em postos de gasolina, há muito detectada por técnicos do órgão ambiental do Estado de São Paulo - a Companhia de Tecnologia de Saneamento Ambiental (Cetesb). Esta resolução resolve, principalmente, que: \"A localização, construção, instalação, modificação, ampliação e operação de postos revendedores, postos de abastecimento, instalações de sistemas retalhistas e postos flutuantes de combustíveis dependerão de prévio licenciamento do órgão ambiental competente...\". A gasolina brasileira possui na sua formulação 20% em média de etanol anidro (teor este que varia de acordo com a política energética momentânea) para aumentar a octanagem e reduzir a emissão de monóxido de carbono na atmosfera. No entanto, esta adição, aumenta sua solubilidade, uma vez que o etanol é solúvel em água e na própria gasolina, aumentando também a mobilidade do contaminante, conseqüentemente dos compostos BTEX (benzeno, tolueno, etilbenzeno, xilenos) e hidrocarbonetos monoaromáticos - altamente nocivos à saúde humana. O município de Guarulhos é uma importante cidade da Região Metropolitana do Estado de São Paulo. Tanto seu pólo industrial - altamente diversificado, quanto a presença do Aeroporto Internacional de São Paulo, com a passagem de cerca de 100 mil pessoas por dia, conferem a cidade grande importância na economia do Estado. A água subterrânea é a única fonte de água potável para consumo de grande parte dos bairros da cidade. No entanto, a cidade apresenta um grande percentual de áreas contaminadas por postos de combustíveis. Considerando a população da cidade é possível perceber que um grande número de pessoas convive diariamente com o problema de áreas passíveis de contaminação por hidrocarbonetos. Tendo em vista a problemática acima exposta, este trabalho visa o levantamento dos dados de contaminação das águas subterrâneas, bem como de solos, pela atividade de postos de gasolina, evidenciando o impacto destas contaminações sobre a população da cidade de Guarulhos. Para tanto, realizou-se estudo na documentação existente nos processos de licenciamento ambiental, bem como de reclamação da população, existentes na Cetesb - Agência Ambiental de Guarulhos, quanto aos aspectos geológicos, hidrogeológicos, técnicos e comunitários quanto à evolução das plumas de contaminação e a discussão das remediações aplicáveis e/ou já aplicadas. Para o desenvolvimento desta pesquisa foram utilizados os laudos de análises, os estudos de passivo ambiental e os demais documentos constantes nos processos de licenciamento, apresentados por estes estabelecimentos à Cetesb, visando à obtenção das licenças a que faz referência a Resolução CONAMA n° 273. As diferenças existentes quanto à condutividade hidráulica e a ocorrência de anisotropia são determinantes quando se trata da direção e velocidade da migração da pluma de contaminação nos diversos tipos de solo. São estas diferenças, alguns dos fatores que, somadas a dispersão e a difusão, condicionam o comportamento dos contaminantes no solo (TRESSOLDI, 2002). É importante comentar que o gerenciamento de uma contaminação envolve a remoção de fase livre de produto, a investigação da contaminação remanescente, a avaliação e gerenciamento de riscos e finalmente as medidas de remediação, no entanto, nenhum dos 5 casos estudados apresentou, até junho de 2006, um projeto de remediação, embora todos já estejam removendo a fase livre de contaminante. Este trabalho elaborou propostas conceituais de remediação, com a utilização de desadsorção térmica em conjunto com atenuação natural, implantação de sistemas de Air Strippers e extração multifásica - MPE. Foram escolhidos dois casos dentre os analisados, pois, até outubro de 2006, ainda não havia sido apresentado nenhum projeto para descontaminação vi destas áreas e, um dos empreendimentos, sequer não havia realizado reforma, o que facilita a remoção do solo para uma melhor remediação. / The Resolution of the Nacional Environment Council - CONAMA n° 237 made obviously the problem concerning fuel leak in gas stations, already detected by technicians of the environmental organ of São Paulo State - Company of Environmental Sanitation Technology (Cetesb). This Resolution establishes that: \"the location, construction, installation, modification, enlargement and operation of gas stations, fuel suppliers, fuel retailers and floating gas stations, will depend on the previous licensing by the competent environmental organ...\". The Brazilian gasoline contains approximately 20% of ethanol anhydrous (the content varies according to the energetic politics) to increase the octane and reduce the emission of carbon monoxide in the atmosphere. Nevertheless, this addition increases its solubility, because the ethanol is soluble in both water and gasoline, increasing the mobility of the contaminant, thus the BTEX compounds (benzene, toluene, ethyl benzene, and xylene) and Monocyclic Aromatic Hydrocarbons - highly toxic to the human health. The municipality of Guarulhos is a very important city of the Metropolitan Region of São Paulo State, due to the diversified industry and the presence of the São Paulo International Airport, where approximately 100 thousand people pass daily. The groundwater is the only source of potable water in many districts of the city. However, there are many contaminated areas by gasoline leaking. So far a great number of people live at areas that are susceptible to the contamination by hydrocarbons compounds. Considering this problem, this research consists in collect data about contaminated groundwater and soil by gas stations operations, verifying the impact of contamination on the population. An investigation of the environment licenses was carried out, as well as the citizens complaints at Cetesb - The environmental Agency in Guarulhos, about geological, hydro geological, technical and community aspects related to the plumes of contamination and their evolution and to discuss the appropriate remedy. To develop this research, the analysis certificate, environmental damage and other documents by the licensing process presented at Cetesb, have been used, to obtain the approval according CONAMA nº 273. The differences about hydraulic conductivity and anisotropy are determinant when talking about direction and speed of the contamination plume migration in different soils. These differences, summed to dispersion and diffusion, condition the behavior of contaminants in the soil (TRESSOLDI, 2002). It is important to know that manage a contamination involves removing the free phase of the product, investigating the contamination left, evaluating and managing the risks and measuring remediation. However, neither one of the five cases presented, until June 2006, a project of treatment, even though all of them are removing the free of contaminants phase. This research elaborated proposals concepts of remediation, using thermal desorption with natural attenuation, implantation of the systems Air Strippers and multiphase extraction - MPE. Two cases were chosen among all the situations analyzed, because until October 2006 no project was presented to de-contaminate those areas, and in one case, no reform was done, what facilitates removing the soil to a better remediation.

Page generated in 0.0401 seconds