• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Caracterização de resíduos de estação de tratamento de água e estudo de reaproveitamento na indústria de cerâmica vermelha

Siqueira Júnior, Bartholomeu 31 January 2011 (has links)
Made available in DSpace on 2014-06-12T17:37:05Z (GMT). No. of bitstreams: 2 arquivo2225_1.pdf: 2046976 bytes, checksum: c7668a1499d0622583ae6d22b6093ddc (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2011 / Companhia Pernambucana de Saneamento / Vários fatores contribuem para a qualidade de vida e saúde da população. Um dos mais importantes é a qualidade da água que utilizamos nas diversas atividades diárias: consumo para eliminar a sede, higiene diária, lavagem dos alimentos, etc. Para que a água atenda aos padrões de potabilidade exigidos pelas legislações específicas ela passa por vários processos de tratamento em unidades denominadas Estações de Tratamento de Água (ETA) e neste tratamento são gerados resíduos denominados lodo de ETA. Este lodo é constituído de todos os resíduos orgânicos e inorgânicos presentes nas águas brutas dos rios e mananciais, tais como: areias, argilas, silte, bactérias, vírus, protozoários, ferro, manganês, cálcio, etc. Desde o começo da utilização de ETAs no tratamento de água até o presente momento, o destino desses resíduos são os corpos d água, sem a realização de nenhum tipo de processamento dos lodos, porém, devido à crescente deterioração dos rios e o interesse da sociedade com o meio ambiente, os órgãos ambientais e o próprio poder público estão exigindo alternativas para esta situação. O tratamento dos lodos das ETAs e sua possível utilização em outros processos produtivos industriais podem ser soluções viáveis a questão, beneficiando a natureza com a redução do impacto ambiental e impedindo que novas matérias-primas sejam retiradas da natureza, além de otimizar os investimentos e minimizar os custos das indústrias. Este trabalho tem como objetivo caracterizar o Lodo da Estação de Tratamento de Água Botafogo, pertencente à Companhia Pernambucana de Saneamento, situada na Cidade de Igarassu-Pernambuco, e analisar sua viabilidade como matéria-prima na indústria de tijolos vermelhos. O lodo é gerado em algumas etapas do processo de tratamento da água bruta e foi tratado na Unidade Piloto de Tratamento de Resíduos de ETA situada dentro desta estação. O resíduo foi submetido aos seguintes ensaios: análise química, através dos resultados da fluorescência de raios - X e difração de raios X(DRX). Para realização destes experimentos foram confeccionados corpos de prova sinterizados em várias temperaturas, que foram caracterizados através dos ensaios cerâmicos de retração linear de queima, absorção de água, perda ao fogo, microscopia ótica, microdureza vickers e resistência à compressão. Os resultados obtidos pelas análises e ensaios indicam o grande potencial para reaproveitamento na indústria de tijolos cerâmicos, pois os corpos de prova apresentaram propriedades compatíveis, inclusive com valores de resistência à compressão superiores aos de blocos cerâmicos. Os melhores resultados foram obtidos nas sinterizações a 1.000ºC, com tratamento térmico anterior, em que se eliminou o material orgânico contido no lodo, demonstrando a necessidade de utilizar processos que retirem este constituinte do resíduo para otimizar suas propriedades
2

Caracterização e utilização de resíduo sólido: lodo de ETA, como matéria prima para confecção de elementos da construção civil

Santos, Selma Souza Alves January 2011 (has links)
87 f. / Submitted by Ana Hilda Fonseca (anahilda@ufba.br) on 2013-04-12T15:01:42Z No. of bitstreams: 2 segunda parte13 12 2011.pdf: 1803059 bytes, checksum: 77dce8aede354949d61ce2f1feeabc83 (MD5) PRIMEIRA PARTE 12 12 2011.pdf: 154138 bytes, checksum: 9b2d71757d09c6b175075617256d6973 (MD5) / Rejected by Ana Hilda Fonseca(anahilda@ufba.br), reason: ficheiro on 2013-05-14T17:06:59Z (GMT) / Submitted by Ana Hilda Fonseca (anahilda@ufba.br) on 2013-05-14T17:10:57Z No. of bitstreams: 1 Dissertação Selma S A Santos.pdf: 1944188 bytes, checksum: b67bb2c70d4b97d9bed39e1571d93961 (MD5) / Approved for entry into archive by Ana Hilda Fonseca(anahilda@ufba.br) on 2013-05-14T17:12:07Z (GMT) No. of bitstreams: 1 Dissertação Selma S A Santos.pdf: 1944188 bytes, checksum: b67bb2c70d4b97d9bed39e1571d93961 (MD5) / Made available in DSpace on 2013-05-14T17:12:07Z (GMT). No. of bitstreams: 1 Dissertação Selma S A Santos.pdf: 1944188 bytes, checksum: b67bb2c70d4b97d9bed39e1571d93961 (MD5) Previous issue date: 2011 / CAPES / A estação de tratamento de água (ETA) Vieira de Mello (VM), uma das ETAs da EMBASA, situada em Salvador-Ba, com capacidade para tratar 2,5 m3 s-1 de água, entrou em operação em março de 1964 atendendo parte da demanda de água potável da cidade de Salvador. Para transformar a água bruta em água potável, a VM utiliza o processo convencional de tratamento, com adição de diversos componentes, formando resíduos a serem removidos nas etapas de decantação e filtração, principalmente nos decantadores, sendo estes resíduos chamados de lodo. A disposição final dos lodos gerados nas ETAs constitui atualmente um dos principais passivos ambientais do setor de saneamento. Há muito, o destino destes resíduos de ETA vinha sendo os cursos d’água próximos das estações, podendo causar efeitos, principalmente à fauna aquática e a saúde humana, pois o mesmo contém metais, tóxicos entre outros contaminantes. Esta prática tem sido questionada por órgãos ambientais. Atualmente, um dos grandes desafios é a busca de destinação final desses lodos, ambientalmente vantajosa e econômica e tecnicamente viável. Entre as possibilidades aponta-se incorporação do lodo em compostagem e seu uso na fabricação de tijolos. Neste estudo realizou-se a caracterização do resíduo gerado na ETA VM, após secagem em estufa sob controle de temperatura na faixa de 103-1050C. Foram encontradas concentrações de metais e semi metais nas faixas de: 6,00 - 9,57 mg L-1 Al; 2,14 – 2,89 mg L-1 As; 0,30 - 0,50 x10-3 mg L-1 Be; < 0,10 – 0,12 x10-3 mg L-1 Cd; 0,83 – 0,14 mg L-1 Cr; <2,0 – 0,11 mg L-1 Pb; 6,50 – 12,50 x 10-3 mg L-1 V. Resultados obtidos de testes de resistência de bloco (fbk =fbk,est= 7,8 Mpa) e de absorção de umidade ( ≤ 13%), além de testes de lixiviação: As < 0,035 mg L-1, Cd < 0,020 mg L-1 ,Pb < 0,20 mg L-1, Cr< 0,070 mg L-1, Al < 1,2 mg L-1, Be< 0,020 mg L-1, V<0,30 mg L-1, comprovam a adequação do lodo para uso na confecção de blocos na construção civil. Como o volume de água tratada em média é 178.710 m3 dia-1 na ETA VM, e a produção de resíduo no final do tratamento é de 42,20 g m-3 SST a produção de blocos por dia poderá ser de 15.814, considerando a composição do material nas seguintes proporções: 1,0: 3,7: 0,85: 0,28 correspondendo a cimento:areia:água:lodo. A tecnologia identificada neste trabalho para a destinação final do resíduo da ETA VM é econômica e ambientalmente adequada. / Salvador
3

Estudo da aplicação do resíduo de decantador de ETA como auxiliar de floculação no tratamento de água / Study of the application of decanters waste of WTP as an aid of flocculation of water treatment

SOUZA, Leonora Milagre de 21 June 2011 (has links)
Made available in DSpace on 2014-07-29T15:01:47Z (GMT). No. of bitstreams: 1 Dissertacao _Leonora Milagre de Souza.pdf: 965865 bytes, checksum: e8839b11b69dccbdd9fd61b7554b691b (MD5) Previous issue date: 2011-06-21 / The residue generated in Water Treatment Plant (WTP) are derived from different stages of water treatment, especially the discharge of decanters. The most common practice in Brazil is the residue disposal directly into rivers, causing negative impacts to the environment. In general, the WTP have difficulties in managing the residue because the high costs of transportation and disposal, the steady increase in the consumption of chemicals, among other complicating factors. Aiming to reduce the coagulant used in the process and improving the characteristics of the residues for the outflow, this research examined the effects of biosolids application decanter of WTP in the processes of coagulation, flocculation and sedimentation of water treatment. Through laboratory tests, using Jar Test, there were three series of tests, each one using gross water with distinct turbidity. In these trials were used differents dosages of aluminum sulfate and applied to WTP samples with different concentrations of total solids suspended (TSS). After the Jar Test, the decanted water was characterized as turbidity and color, solids and coliforms were not found significant changes in their quality. For most situations, the residue application in treatment has reduced the coagulant in the range 50% to 60%. The increased turbidity of gross water allowed the application of more concentrated residue without reducing the efficiency of treatment in terms of turbidity removal. Regarding the sedimented material in the Jar Test, the decreasing of the dosage of coagulant favored the reduction of the occupied volume by the material, independent of the concentration of residue applied. The specific resistance of sedimented material was higher when compared to the situation without the application in virtually all studied situations. For water with 100 NTU and implementation of residue greater than 7.500 mg/L, and water with 210 NTU and residue less than 8.600 mg/L there was improvement in the sedimentability. The dewatering ability of the sediments by centrifugation was also improved with the application of the residue with 3.642 mg/L and 75% of the coagulant, and 7.500 mg/L using 50% of coagulant. The chemical conditioning by nonionic polyelectrolyte did not improved in the dewatering of sedimented material, but in improving water quality supernatant. Based on this study it was noticed that the application of WTP residue in water treatment was satisfactory as for the analyzed parameters, considering the dosage of coagulant used and the residue applied. / Os resíduos gerados nas Estações de Tratamento de Água (ETAs) são decorrentes das diversas etapas do tratamento da água, em especial da descarga de decantadores. A prática mais comum no Brasil de disposição desse resíduo é diretamente em corpos hídricos, podendo causar impactos negativos ao meio ambiente. Em geral, as ETAs apresentam dificuldades no gerenciamento dos resíduos devido os altos custos com transporte e disposição, o aumento constante no consumo de produtos químicos, dentre outros complicadores. Visando a redução de coagulante utilizado no processo e a melhoria das características desse resíduo para o deságue, a presente pesquisa analisou os efeitos da aplicação do resíduo de decantador de Estação de Tratamento de ETA (ETA) nos processos de coagulação, floculação e sedimentação do tratamento de água. Por meio de ensaios laboratoriais, utilizando Jar Test, foram realizadas três séries de ensaios, cada uma utilizando água bruta com turbidez distinta. Nesses ensaios foram empregadas dosagens variadas de sulfato de alumínio e aplicadas amostras de resíduo da ETA com concentrações de sólidos suspensos totais (SST) diferentes. Após a realização dos ensaios de Jar Test, a água decantada foi caracterizada quanto à turbidez, cor aparente, concentração de sólidos e coliformes, não sendo verificadas alterações significativas em sua qualidade. Para a maioria das situações, a aplicação do resíduo no tratamento possibilitou a redução de coagulante na faixa de 50% a 60%. O aumento da turbidez da água bruta permitiu a aplicação do resíduo mais concentrado, sem reduzir a eficiência do tratamento quanto a remoção de turbidez. Com relação ao material sedimentado gerado nos ensaios de Jar Test, a redução da dosagem de coagulante favoreceu a redução do volume ocupado pelo material, independente da concentração de resíduo aplicado. A resistência específica do material sedimentado foi maior se comparada à situação sem aplicação do resíduo, em praticamente todas as situações estudadas. Para a água com 100 UNT e aplicação do resíduo maior que 7.500 mg/L, e água com 210 UNT e resíduo menor que 8.600 mg/L houve melhora na sedimentabilidade. O deságue do material sedimentado por meio de centrifugação também melhorou com a aplicação dos resíduos com 3.642 mg/L e 75% de coagulante, e 7.500 mg/L utilizando 50% de coagulante. O condicionamento químico por meio de polieletrólito não iônico não auxiliou no desaguamento do material sedimentado, e sim na melhoria da qualidade da água sobrenadante. Baseado neste estudo percebeu-se que a aplicação do resíduo da ETA no tratamento de água foi satisfatória quanto aos parâmetros analisados, devendo ser levada em consideração a dosagem de coagulante empregada e a concentração do resíduo aplicado.
4

Estudo em escala real da disposição de resíduo de decantador de ETA em lagoa de estabilização de esgoto / Real scale study on WTP residuals disposal in wastewater stabilization pond

Angelim, Susane Campos Mota 29 April 2015 (has links)
Submitted by Luciana Ferreira (lucgeral@gmail.com) on 2015-12-07T10:42:20Z No. of bitstreams: 3 Dissertação - Susane Campos Mota Angelim - 2015 (1).pdf: 18841997 bytes, checksum: 81d8b3c8746995f8815dfec4fc05909b (MD5) Dissertação - Susane Campos Mota Angelim - 2015 (2).pdf: 3115044 bytes, checksum: fb522cec32010b346517744c51a7c7c7 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2015-12-07T10:45:43Z (GMT) No. of bitstreams: 3 Dissertação - Susane Campos Mota Angelim - 2015 (1).pdf: 18841997 bytes, checksum: 81d8b3c8746995f8815dfec4fc05909b (MD5) Dissertação - Susane Campos Mota Angelim - 2015 (2).pdf: 3115044 bytes, checksum: fb522cec32010b346517744c51a7c7c7 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2015-12-07T10:45:43Z (GMT). No. of bitstreams: 3 Dissertação - Susane Campos Mota Angelim - 2015 (1).pdf: 18841997 bytes, checksum: 81d8b3c8746995f8815dfec4fc05909b (MD5) Dissertação - Susane Campos Mota Angelim - 2015 (2).pdf: 3115044 bytes, checksum: fb522cec32010b346517744c51a7c7c7 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Previous issue date: 2015-04-29 / Fundação de Amparo à Pesquisa do Estado de Goiás - FAPEG / In Brazil water treatment plants (WTP) residuals are usually discharged into waterways, with negative impacts on water quality, aquatic biota and sediments, which may also pose risks to human health. This paper presents a study on real scale disposal of aluminum sludge from the settling of a WTP in a primary facultative pond, both located in Piracanjuba-GO, wishing to contribute as an alternative for residuals management. The study aimed to evaluate the effects of WTP residuals (WTPR) in the performance of the wastewater stabilization pond (WSP), in terms of quality of the effluent and volume of bottom sludge accumulated. Worked up in two identical parallel ponds, one in which WTPR was applied (test pond) and another without application (control pond) to serve as comparison of results. The study was carried out in two stages, with dosage of 37 mg TS/L in Phase 1 and 44 mg TS/L in Phase 2, totaling 125 days of application and 191 days of monitoring. It was evaluated several effluent parameters such as BOD, solids, nitrogen, total phosphorus, Escherichia coli, metals, among others. Sludge volumes in the ponds were obtained from bathymetric survey using a sludge depth meter (sludge gun) and modeling by Surfer 8.0 software. The addition of the WTPR did not impair the performance of the test pond, with minimal reduction of BOD and nitrogen. It was not possible to identify any influence of WTPR for the removal of total phosphorus of the sewage, which was attributed to high pH and low dosage. There was no statistical difference (95% confidence level) between the means of 15 parameters evaluated in two phases, except for nitrogen ammonia. There was no difference between the increases of sludge volume accumulated in the bottom of the ponds, although total solids content was higher in the test pond. This behavior was associated with particle size characteristics of the material. The study indicates technical feasibility of WTP residuals disposal in the WSP studied, revealing an alternative for its management that can also be applied in other same type systems if evaluated the specific conditions in each case. / A realidade brasileira atual é de que a grande maioria dos resíduos de ETA são lançados diretamente em cursos d'água, com impactos negativos sobre a qualidade das águas, biota aquática e sedimentos, podendo também representar riscos à saúde humana. O trabalho apresenta um estudo em escala real da disposição do resíduo do decantador da ETA do tipo convencional (ou de ciclo completo) da cidade de Piracanjuba-GO, cujo coagulante utilizado é o sulfato de alumínio, na lagoa facultativa primária da ETE Piracanjuba, visando contribuir como alternativa adequada para a gestão dos resíduos sólidos de sistemas de saneamento. O trabalho teve como objetivo avaliar os efeitos da disposição do resíduo no desempenho da lagoa quanto à qualidade do efluente líquido e ao volume do lodo de fundo acumulado. Trabalhou-se com duas lagoas idênticas em paralelo, uma de teste, onde foi aplicado o resíduo, e outra de referência, sem aplicação, para servir de comparação dos resultados. O estudo foi realizado em duas fases de aplicação do resíduo e monitoramento das lagoas, com dosagem de 37 mgSTresíduo (bs)/Lesgoto na Fase 1 e 44 mgSTresíduo (bs)/Lesgoto na Fase 2, totalizando 125 dias de aplicação e 191 dias de monitoramento. Foram avaliados diversos parâmetros físico-químicos do efluente, tais como DBO, SST, Namoniacal, fósforo total, E.coli, metais, dentre outros. Os volumes de lodo nas lagoas foram obtidos a partir de levantamento batimétrico com uso de medidor de óptico de lodo (Sludge Gun) e calculados por modelagem matemática pelo programa Surfer 8.0. A adição do resíduo de ETA não prejudicou o desempenho da lagoa facultativa de teste, com discreta redução de DBO e Namoniacal. Não foi possível apontar nenhuma influência do resíduo de ETA sobre a remoção de fósforo total do esgoto, o que foi atribuído a fatores como elevado pH e baixa dosagem. Na análise estatística dos resultados do efluente, ao nível de confiança de 95%, não foram verificadas diferenças estatísticas entre as médias dos 15 parâmetros avaliados nas duas fases, exceto para Namoniacal. Não houve diferença entre os acréscimos de volume de lodo de fundo acumulado nas lagoas, sendo que concentração de sólidos totais do lodo de fundo foi maior na lagoa de teste. Esse comportamento foi associado a características granulométricas do material. O estudo indica a viabilidade técnica da disposição do resíduo da ETA nas lagoas facultativas da ETE Piracanjuba, mostrando-se como uma alternativa ambientalmente adequada para a gestão do resíduo, que pode ser aplicada também em outros sistemas de mesmas tipologias, desde que avaliadas as condições específicas de cada caso.

Page generated in 0.251 seconds