• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 117
  • 13
  • 8
  • 3
  • 1
  • 1
  • Tagged with
  • 149
  • 149
  • 120
  • 91
  • 72
  • 46
  • 43
  • 36
  • 33
  • 32
  • 32
  • 29
  • 29
  • 29
  • 27
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Análise da qualidade da polimerização e da degradação de cimentos resinosos utilizados na cimentação de pinos de fibra de vidro por meio de testes de microdureza / Microhardness analysis of the polymerization quality and degradation of resin cements used for fiber posts cementation

Pedreira, Ana Paula Ribeiro do Vale 16 April 2007 (has links)
Os cimentos resinosos têm sido largamente utilizados em odontologia restauradora com a finalidade de reter o pino intra-radicular e dissipar tensões entre este e a raiz. Entretanto, o grau de conversão alcançado pelos mesmos influencia suas propriedades mecânicas, biocompatibilidade e degradação pela água e pelos ácidos bucais. Testes de microdureza podem ser aplicados para estimar o grau de conversão de compósitos, uma vez que apresentam boa correlação com a espectroscopia infravermelha. Este trabalho objetivou analisar a microdureza de quatro cimentos resinosos de polimerização dual utilizados na cimentação de pinos de fibra de vidro, nos períodos inicial, após 24 horas de imersão em etanol a 75% e após 3 meses de armazenamento em água, e testar a hipótese de que não há diferença entre a microdureza dos terços cervical, médio e apical na linha de cimento. Quarenta incisivos bovinos tratados endodonticamente foram distribuídos em quatro grupos para a cimentação de pinos Fibrekor® (Jeneric/Pentron) de 1mm de diâmetro, sendo: Grupo 1 - Panavia F 2.0 (Kuraray Medical Inc.), Grupo 2 - Variolink (Ivoclar), Grupo 3 - Rely X Unicem (3M ESPE) e Grupo 4 - Duolink (Bisco). Após a cimentação, as raízes foram divididas em 2 subgrupos, sendo 5 seccionadas após 7 dias para análise da microdureza inicial e 5 mantidas íntegras em água deionizada por 3 meses, para avaliação da microdureza final no microdurômetro Shimadzu HMV (Japan). Após a mensuração inicial, as raízes seccionadas eram armazenadas a 37º C por 24h em 10mL de solução de etanol a 75%, e reavaliadas. Foram identificadas diferenças estatisticamente significativas entre cimentos, terços e períodos (inicial ou após 24h de imersão em etanol a 75%), bem como interações entre cimento/terços e cimento/períodos de avaliação. O cimento Panavia exibiu os valores de microdureza inicial significativamente superiores, sem diferença estatística entre os demais cimentos. Os valores de microdureza inicial por terços não seguiram um padrão homogêneo; os cimentos Variolink e Duolink exibiram valores de microdureza significativamente superiores no terço cervical, sem diferença significativa entre os terços para os demais cimentos. A imersão em etanol reduziu significativamente a média dos valores de dureza para todos os cimentos; o comportamento por terços variou em função do material. O armazenamento em água por 3 meses não exerceu influência sobre a dureza da maioria dos cimentos, com exceção do Unicem, que exibiu aumento significativo dos valores de dureza após esse período. Portanto, a hipótese proposta neste estudo foi rejeitada. / Resin cements have been largely used in dentistry for retaining intraradicular posts and to minimize tension between them. However, the degree of conversion influences mechanical properties, biocompatibility and susceptibility of water and acid degradation of these polymers. Hardness tests are used to estimate the degree of conversion of composites, as it shows good correlation with infrared spectroscopy. The aim of this study was to evaluate the microhardness of four resin cements used for fiber posts cementation at the nitial period, 24h-immersion in a 75% ethanol solution and after 3-month water storage. Forty bovine incisives were endodontically treated and restored with 1mm diameter Fibrekor® posts (Jeneric/Pentron), being: Group 1 - Panavia F 2.0 (Kuraray Medical Inc.), Group 2 - Variolink (Ivoclar), Group 3 - Rely X Unicem (3M ESPE) and Group 4 - Duolink (Bisco). After cementation, each group was divided in two subgroups: 5 roots were sectioned 7 days after cementation for initial hardness measurement and 5 roots were immersed in deionized water for 3 months for final hardness measurements using Shimadzu Micro Hardness Tester (HMV, Japan). After the initial measurements, the sectioned roots were immersed in 10mL 75% ethanol solution for 24h at 37ºC, and tested again. Differences in hardness values have been detected among resin cements, radicular thirds and periods (initial or 24h-immersion in a 75% ethanol solution). Data also revealed significant interaction to cement/third and cement/period of evaluation. Panavia showed higher hardness values, with no statistical differences among the other cements. It was not verified a homogeneous pattern regarding radicular third; Variolink and Duolink exhibited higher hardness values for the cervical third, without differences among radicular thirds for the other cements. Hardness values decreased after ethanol immersion for all resin cements and the hardness according to radicular thirds varied among the materials. The hardness of tested resin cement showed no influence after 3-month water storage, except for Unicem as it showed an increase in Knoop hardness after this period. Therefore, the null hypotesis proposed was rejected.
32

Cimentação de laminados cerâmicos : efeito de diferentes modos de fotoativação na estabilidade de cor e nas propriedades mecânicas de sistemas adesivos e cimentos resinosos /

Sahyon, Henrico Badaoui Strazzi. January 2017 (has links)
Orientador: Paulo Henrique dos Santos / Banca: Wirley Gonçalves Assunção / Banca: Anderson Catelan / Resumo: O objetivo deste estudo in vitro foi avaliar os efeitos de diferentes modos de fotoativação na nanodureza e módulo de elasticidade de sistemas adesivos e cimentos resinosos, assim como o efeito na estabilidade de cor de laminados cerâmicos. Os fatores em estudos foram: dois níveis de fotopolimerizadores (VALO - Ultradent; Radii-Cal - SDI) e três níveis de modo de ativação (sem polimerização prévia do sistema adesivo na superfície dental e no interior do laminado cerâmico; polimerização prévia do sistema adesivo somente na superfície dental; e polimerização prévia do sistema adesivo na superfície dental e no interior do laminado cerâmico). Na análise da estabilidade de cor o terceiro fator estudado foi o tempo de envelhecimento (252, 504 e 756 horas). Foram confeccionados 132 blocos de cerâmica (7x8x0,6mm) de dissilicato de lítio (IPS e-max CAD), os quais foram cimentados sobre o esmalte dentário dos dentes bovinos, distribuídos em 12 grupos de acordo com os materiais restauradores e métodos de procedimentos utilizados. Dois sistemas adesivos e cimentos resinosos foram utilizados (Single Bond Universal/RelyX Veneer- 3M/ESPE e Tetric N Bond/Variolink Veneer - Ivoclar Vivadent). As propriedades mecânicas de nanodureza e módulo de elasticidade foram mensuradas utilizando nanodurômetro (Anton Paar), sob ação de carga de 1000μN (n=3). A estabilidade de cor foi mensurada através do espectrofotômetro de reflexão ultravioleta visível UV-2450 (Shimadzu) antes e após a submissão das amo... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The purpose of this in vitro study was to evaluate the effects of different modes of photoactivation in the nanohardness and elastic modulus of resin cements and adhesives, as well as the effect on the color stability of ceramic laminates. The factors of the studies were: two levels of light curing units (VALO - Ultradent; Radii-Cal - SDI) and three modes of photoactivation (without prior curing of the adhesive system in the tooth surface and inside of the ceramic laminate, prior curing the adhesive system only in the tooth surface, and prior curing of the adhesive system in the tooth surface and within the ceramic laminate). In the analysis of color stability the third factor of the study was the aging time (252, 504 and 756 hours). One hundred and thirty two ceramic blocks (7x8x0.6mm) of lithium dissilicate (IPS e-max CAD) were made, which were cemented on the enamel of bovine teeth, and distributed into 12 groups according to the restorative materials (Single Bond Universal/RelyX Veneer - 3M/ESPE and Excite DSC/Variolink Veneer - Ivoclar Vivadent) and methods of procedures. The mechanical properties of nanohardness and elastic modulus were measured using a nanohardness tester (Anton Paar) under loaf of 1000 μN (n=3). Color stability was measured using a UV-2450 visible UV spectrophotometer (Shimadzu) before and after the submission of the UVB artificial accelerated aging samples (n=8). Data of color stability and mechanical properties were submitted to statistical testes o... (Complete abstract click electronic access below) / Mestre
33

Avaliação da dureza superficial de cimentos resinosos utilizados na cimentação de pinos de fibra de vidro

Grande, Fernanda Zander 21 February 2006 (has links)
Made available in DSpace on 2017-07-24T19:22:11Z (GMT). No. of bitstreams: 1 Fernanda Zander.pdf: 940456 bytes, checksum: 47429e6712305973cd3b486e5ac590f1 (MD5) Previous issue date: 2006-02-21 / The purpose of this study was to investigate the interaction between two methods of adhesive systems activation (chemically cured and dual cured) and two methods of resin cements activation (chemically cured and dual cured) in Vickers microhardness values of resin cements, in differents depths of cure and differents distances of the adhesive systems used. There were 50 bovin inferior incisives which had their crowns transversaly crosscuted to use the root portion. The canal roots were prepared to the fiber posts cementation. The teeth were randomly divided in five groups: I) Adhesive system Prime & Bond 2.1 with Self Cure Activator and dual resin cement EnForce; II) Adhesive system Prime & Bond 2.1 and dual resin cement EnForce; III) ED Primer and chemically cured resin cement Panavia 21; IV) Adhesive system Clearfil SE Bond and chemically cured resin cement Panavia 21 e V) Adhesive system Prime & Bond 2.1 with Self Cure Activator and dual resin cement EnForce. In group V The EnForce wasn’t light-cured standing only with the chemically activation. After posts cementation the roots were cuted in 3 portions with 3 mm eatch (cervical, medium and apical) and after 7 days the specimens were tested. The specimens were divided in quadrants that recived 2 identations, one next the fiber post and other next the canal root surface. Data were submitted to threeway ANOVA and Tukey’s test. The application of these tests revealed statistically significant differences for the variables: group, position, region; interaction between group and position (p< 0,001), and interaction between group and region (p= 0,041). There weren’t, however, statistically significant differences interaction between position and region (p= 0.85). The conclusions were: the superficial hardness, independently of the kind of cement and adhesive system was always present in all regions of root canal; the chemically cured resin cement demonstrated the higher values of hardness; the factor depth of cure interfered in superficial hardness values in all groups, being more evident in GI and GII than GIII, GIV e GV; there was interference of adhesive systems in microhardness values for all groups, what can be observed in smaller values found next the adhesive systems. It was more evident in GIV that used the self-etched adhesive system and less evident in GIII that used ED Primer. The findings of this study demonstrates that the pH of adhesive systems inluences the microhardness values of resin cements. / O objetivo deste trabalho foi analisar a interação de dois tipos de ativação de sistemas adesivos (fotoativável e ativação dual) e dois tipos de ativação de cimentos resinosos (ativação química e ativação dual) nos valores de microdureza Vickers dos cimentos em diferentes profundidades de polimerização e diferentes proximidades com o sistema adesivo utilizado. Foram utilizados 50 incisivos bovinos inferiores que tiveram suas coroas seccionadas transversalmente para a utilização da porção radicular. Os condutos radiculares foram preparados para a cimentação de pino de fibra de vidro. Os dentes foram divididos aleatoriamente em cinco grupos: I) Sistema adesivo Prime & Bond 2.1 com Self Cure Activator e cimento resinoso dual EnForce; II) Sistema adesivo Prime & Bond 2.1 e cimento resinoso dual EnForce; III) ED Primer e cimento resinoso químico Panavia 21; IV) Sistema adesivo Clearfil SE Bond e cimento resinoso químico Panavia 21 e V) Sistema adesivo Prime & Bond 2.1 com Self Cure Activator e cimento resinoso dual EnForce. No grupo V o cimento EnForce não foi fotoativado ficando apenas com a ativação química. Após a cimentação dos pinos as raízes foram então seccionadas em três secções de 3 mm de espessura (cervical, média e apical) e após sete dias foi feita a análise da microdureza Vickers. As secções de cada terço foram divididas em quadrantes iguais e em cada quadrante foram realizadas duas identações, sendo uma próxima ao pino de fibra de vidro e a outra próxima à parede do conduto radicular. Os resultados foram submetidos à análise estatística ANOVA três critérios, havendo diferença estatística entre os grupos foi feito o teste de Tukey para a comparação dos grupos dois a dois. A aplicação do teste de Análise de Variância à três critérios revelou haver diferenças estatisticamente significantes para as variáveis independentes: grupo, posição, região, interação entre grupo e posição (p<0,001), e interação entre grupo e região (p=0,041), não havendo, contudo, diferença estatisticamente significante para as interações entre posição e região (p=0,983) e para a interação entre grupo, posição e região (p=0,85). Concluiu-se que: a dureza superficial, independente do tipo de cimento e dos sistemas adesivos esteve sempre presente em todas as regiões analisadas do canal radicular; o cimento resinoso quimicamente ativado (GIII) apresentou maiores valores de dureza superficial quando comparado ao cimento resinoso de dupla ativação, independente da região analisada do canal radicular; o fator profundidade de polimerização interferiu nos valores de dureza superficial em todos os grupos, sendo mais evidente para os grupos onde o cimento foi fotoativado (GI e GII) do que para os grupos com ativação química (GIII, GIV e GV) que mostraram maior uniformidade nos três terços do conduto radicular; Houve interferência dos sistemas adesivos utilizados nos valores de microdureza para todos os grupos, o que pode ser observado nos menores valores encontrados próximo aos sistemas adesivos, sendo mais evidente no GIV que utilizou o sistema adesivo autocondicionante e menos evidente no grupo III que utilizou o Primer do próprio cimento, mostrando a incompatibilidade entre os sistemas adesivos com menor pH e a fase quimicamente ativada dos cimentos resinosos. O objetivo deste trabalho foi analisar a interação de dois tipos de ativação de sistemas adesivos (fotoativável e ativação dual) e dois tipos de ativação de cimentos resinosos (ativação química e ativação dual) nos valores de microdureza Vickers dos cimentos em diferentes profundidades de polimerização e diferentes proximidades com o sistema adesivo utilizado. Foram utilizados 50 incisivos bovinos inferiores que tiveram suas coroas seccionadas transversalmente para a utilização da porção radicular. Os condutos radiculares foram preparados para a cimentação de pino de fibra de vidro. Os dentes foram divididos aleatoriamente em cinco grupos: I) Sistema adesivo Prime & Bond 2.1 com Self Cure Activator e cimento resinoso dual EnForce; II) Sistema adesivo Prime & Bond 2.1 e cimento resinoso dual EnForce; III) ED Primer e cimento resinoso químico Panavia 21; IV) Sistema adesivo Clearfil SE Bond e cimento resinoso químico Panavia 21 e V) Sistema adesivo Prime & Bond 2.1 com Self Cure Activator e cimento resinoso dual EnForce. No grupo V o cimento EnForce não foi fotoativado ficando apenas com a ativação química. Após a cimentação dos pinos as raízes foram então seccionadas em três secções de 3 mm de espessura (cervical, média e apical) e após sete dias foi feita a análise da microdureza Vickers. As secções de cada terço foram divididas em quadrantes iguais e em cada quadrante foram realizadas duas identações, sendo uma próxima ao pino de fibra de vidro e a outra próxima à parede do conduto radicular. Os resultados foram submetidos à análise estatística ANOVA três critérios, havendo diferença estatística entre os grupos foi feito o teste de Tukey para a comparação dos grupos dois a dois. A aplicação do teste de Análise de Variância à três critérios revelou haver diferenças estatisticamente significantes para as variáveis independentes: grupo, posição, região, interação entre grupo e posição (p<0,001), e interação entre grupo e região (p=0,041), não havendo, contudo, diferença estatisticamente significante para as interações entre posição e região (p=0,983) e para a interação entre grupo, posição e região (p=0,85). Concluiu-se que: a dureza superficial, independente do tipo de cimento e dos sistemas adesivos esteve sempre presente em todas as regiões analisadas do canal radicular; o cimento resinoso quimicamente ativado (GIII) apresentou maiores valores de dureza superficial quando comparado ao cimento resinoso de dupla ativação, independente da região analisada do canal radicular; o fator profundidade de polimerização interferiu nos valores de dureza superficial em todos os grupos, sendo mais evidente para os grupos onde o cimento foi fotoativado (GI e GII) do que para os grupos com ativação química (GIII, GIV e GV) que mostraram maior uniformidade nos três terços do conduto radicular; Houve interferência dos sistemas adesivos utilizados nos valores de microdureza para todos os grupos, o que pode ser observado nos menores valores encontrados próximo aos sistemas adesivos, sendo mais evidente no GIV que utilizou o sistema adesivo autocondicionante e menos evidente no grupo III que utilizou o Primer do próprio cimento, mostrando a incompatibilidade entre os sistemas adesivos com menor pH e a fase quimicamente ativada dos cimentos resinosos.
34

INFLUÊNCIA DE DIFERENTES TRANSLUCIDEZ DAS CERÂMICAS SOBRE O GRAU DE CONVERSÃO E MICRODUREZA DE UM CIMENTO RESINOSO DUAL / Influence of different ceramic translucency on the degree of conversion and microhardness of dual resin cement

Sakamoto Junior, Antonio Setsuo 24 February 2012 (has links)
Made available in DSpace on 2017-07-24T19:22:20Z (GMT). No. of bitstreams: 1 Antonio S Sakamoto Jr.pdf: 1530054 bytes, checksum: 0cc1d22fb0f1bb5e13c6f006184f113e (MD5) Previous issue date: 2012-02-24 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The proposition of this study was to evaluate the influence of different ceramic translucency on the degree of conversion and Knoop microhardness of dual resin cement. It was made 150 samples of the resin cement dual cured Variolink II (shade A3; 5 mm in diameter and 1 mm thick) were created with interposing ceramic discs with 8 mm in diameter and 1.5 mm thick varying translucency (IPS e.max HT, HO, ZirPress HT and IPS d.SIGN). The control group was created without the interposition of ceramics. The experimental groups were photoactivated in three different times: 20, 40 and 60 seconds. 75 specimens were measured by Fourier transformed infrared spectroscopy (FTIR) to assess the degree of conversion (%). Another 75 specimens were used for the microhardness test, previously they were ground under water irrigation with grit silicon carbide granulation 320, 400, 600, 1000, 1200, finishing them with felt cloth and diamond paste with grain 1 and ¼ micrometers. Each sample was divided into four quadrants and conducted an indentation in each quadrant and then was calculated the average of these indentations. The values of the degree of conversion and Knoop hardness were analized by two-way ANOVA (type of ceramic and time of photoactivation), Bonferroni’s multiple comparison tests with a significance level of 5% and the Spearman correlation. The degree of conversion values of ceramic with high translucency were similar to the control group, the HO group presented the lowest conversion values, however when the curing time has tripled from 20 to 60 seconds, the values increased 63.9%. Translucent ceramic without infrastructure (IPS d.SIGN) presented higher microhardness values than ceramics with lithium disilicate infrastructure-based (e.max HT and HO). The negative effects of increased opacity of the ceramic on the dual resin cement can be avoided with increased time of photoactivation. / A proposição deste trabalho foi avaliar a influência de cerâmicas de diferentes translucidez sobre o grau de conversão (GC) e microdureza Knoop de um cimento resinoso dual. Foram confeccionados 150 corpos de prova do cimento resinoso dual Variolink II (cor A3; 5 mm de diâmetro e 1 mm de espessura) interpondo discos cerâmicos com 8 mm de diâmetro e 1,5 mm de espessura variando-se a translucidez da cerâmica (IPS e.max HT, HO, ZirPress HT e IPS d.SIGN). O grupo controle foi confeccionado sem interposição da cerâmica. Os grupos experimentais foram fotoativados em 3 diferentes tempos: 20, 40 e 60 segundos. Para o grau de conversão (%) foram utilizados 75 corpos de provas, onde foram mensurados através da Espectroscopia por infra vermelho por transformação de Fourier (FTIR). Para o teste de microdureza foram usados 75 corpos de prova, onde estes foram lixados sob irrigação de água com lixas de carbeto de silício de granulação 320, 400, 600, 1000, 1200, finalizando-os com pano de feltro e pasta diamantada com granulação de 1 e ¼ μm. Cada corpo de prova foi divido em 4 quadrantes erealizado uma indentação em cada quadrante e em seguida foi calculado a média destas indentações. Os valores do grau de conversão e de microdureza Knoop foram submetidos à análise de variância de dois fatores (tipo de cerâmica e tempo), pós-teste de Bonferroni com nível de significância de 5% e à correlação de Spearman. Os valores de GC para as cerâmicas de alta translucidez foram semelhantes ao grupo controle, o grupo HO apresentaram os menores valores de GC, porém obteve um aumento de 63,9% quando o tempo de fotoativação foi triplicado de 20 para 60 segundos. Já os valores de microdureza superficial foram maiores para as cerâmicas com maior translucidez sem infraestrutura (IPS d.SIGN), as cerâmicas com infraestrutura à base de dissilicato de lítio (e.max HT e HO). Os efeitos negativos da maior opacidade da cerâmica sobre o cimento resinoso dual podem ser evitados com aumento no tempo de fotoativação.
35

Nanotubos de nitreto de boro como carga para resinas adesivas

Degrazia, Felipe Weidenbach January 2017 (has links)
O objetivo do presente estudo foi desenvolver e avaliar a incorporação de nanotubos de Nitreto de Boro (BNNT) como carga em uma resina adesiva. Foi formulada uma resina adesiva utilizando-se os seguintes reagentes: 2- hidróxietil metacrilato (HEMA), Bisfenol A glicol dimetacrilato (BisGMA), canforoquinona (CQ) e Etil 4-dimetilaminobenzoato (EDAB). Os BNNTs foram caracterizados por Microscopia Eletrônica de Varredura (MEV) e Microscopia Eletrônica de Transmissão (MET). O adesivo experimental com diferentes concentrações de BNNT (0, 0,05, 0,075, 0,1 e 0,15%) foi caracterizado quanto ao ângulo de contato e energia livre de superfície (ELS), dureza e amolecimento em solvente (solução de etanol) em microdurômetro, deposição mineral até 14 dias e grau de conversão por espectroscopia Raman e resistência coesiva. O adesivo experimental com diferentes concentrações de BNNT após imersão por 3 h em 65% HNO3 e 48 h em H2O2 foi caracterizado por grau de conversão e cinética de polimerização por Espectroscopia de infravermelho por transformada de Fourier (FTIR), ângulo de contato em dentina por tensiômetro, citotoxicidade por sulforodamina B (SRB) e resistência de união imediata e longitudinal Os resultados da análise de microscopia eletrônica de varredura e de transmissão demonstraram nanotubos de nitreto de boro com diâmetros de 5 a 10 nanometros com término fechado. Nenhuma modificação no grau de conversão ocorreu após a incorporação de BNNTs até 0,15%. Os ângulos de contato de água e α-bromonaftaleno aumentaram (p < 0,05) e consequentemente a ELS diminuiu após a incorporação de BNNTs ao adesivo. Houve aumento da microdureza e da resistência ao amolecimento em solvente após incorporação de 0,075, 0,1 e 0,15% de BNNTs. Não houve diferença significativa na resistência coesiva entre os diferentes grupos. Foi encontrada deposição mineral nos espécimes com BNNT após sete dias de imersão em SBF (fluido corporal simulado). Após o tratamento dos BNNTs com HNO3 e H2O2 e incorporação ao adesivo, houve aumento do grau de conversão e da taxa de polimerização máxima após incorporação de 0,075 e 0,1% de BNNT. O ângulo de contato à dentina aumentou após a incorporação de 0,15% BNNT. Não houve diferença significativa na resistência de união entre os grupos após 24 h (p >0,05). Após 6 meses a resistência de união diminuiu significativamente para o grupo 0% e 0,15% BNNT. Entretanto, os grupos que tiveram incorporação de BNNT obtiveram maiores valores que 0% (p <0,05). Não houve diferença no crescimento celular (p >0,05) entre os grupos em comparação ao grupo controle positivo (100% de crescimento). A incorporação de BNNT até 0,15% melhorou as propriedades físico-químicas do adesivo dentário, promoveu deposição mineral e aumentou a estabilidade longitudinal sem apresentar citotoxicidade a fibroblastos, fornecendo benefícios consideráveis frente aos materiais disponíveis no mercado. / The aim of this study was to develop and evaluate the incorporation of boron nitride nanotubes (BNNTs) into an adhesive resin. An adhesive resin was developed using the following reagents: 2-hydroxyethyl methacrylate (HEMA), bisphenol-A glycidyl dimethacrylate (BisGMA), camphorquinone (CQ) e ethyl 4- dimethylaminobenzoate (EDAB). BNNTs were characterized by Scanning Electron Microscopy (SEM) and Transmission Electron Microscopy (TEM). The experimental adhesive with different concentrations of BNNT (0, 0.05, 0.075, 0.1 e 0.15%) was characterized by contact angle and surface free energy (SFE), hardness and softening in solvent (ethanol solution) by microdurometer, mineral deposition up to 14 days and degree of conversion by Raman spectroscopy and ultimate tensile strength test. The experimental adhesive with different concentrations of BNNT after immersion for 3 h in 65% HNO3 and 48 h in H2O2 was characterized by degree of conversion and polymerization kinetics by Fourier Transform Infrared Spectroscopy (FTIR), contact angle in dentin by tensiometer, sulforhodamine B (SRB) cytotoxicity and immediate and longitudinal bond strength. The results of scanning and transmission electron microscopy showed boron nitride nanotubes with diameters of 5 to 10 nanometers with closed end tips No change in degree of conversion occurred after the incorporation of BNNTs up to 0.15%. The contact angles of water and α-bromonaphthalene increased (p <0.05) and consequently SFE decreased after the incorporation of BNNTs to adhesive. After incorporation of 0.075, 0.1 and 0.15% BNNTs an increase was shown in microhardness and resistance to softening in solvent. No significant difference in ultimate tensile strength was found among groups. Mineral deposition was found on BNNT specimens after seven days of immersion in SBF (simulated body fluid). After BNNTs´ treatment with HNO3 and H2O2 and incorporation into the adhesive, there was an increase in the degree of conversion and the maximum polymerization rate after incorporation of 0.075 and 0.1% of BNNT. Contact angle in dentin increased after incorporation of 0.15% BNNT. There was no significant difference in microtensile bond strength among groups after 24 h (p> 0.05). After 6 months the bond strength decreased significantly for 0% group and 0.15% BNNT. However, the groups that had BNNT incorporation obtained higher values than 0% (p <0.05). There was no difference in cell growth (p> 0.05) among groups compared to the positive control group (100% growth). The incorporation of BNNT up to 0.15% improved the physicochemical properties of dental adhesive, promoted mineral deposition and increased longitudinal stability with no cytotoxicity to fibroblasts, providing considerable benefits against dental materials available in the market.
36

Influência de três sistemas adesivos na resistência à extrusão de pinos de fibras de vidro fixados com um cimento resinoso / Influence of three adhesives systems on the extrusion strength of glass fiber posts fixed by resin cements

Raineri, Juliana Cefaly 03 May 2006 (has links)
Com o intuito de elevar os valores de resistência à fratura dos dentes que sofreram tratamento endodôntico, várias técnicas restauradoras têm sido desenvolvidas. Atualmente os sistemas de pinos de fibras de carbono e de vidro são os dispositivos mais utilizados, devido às suas vantagens de possuírem módulo de elasticidade próximo ao da dentina, o que causa menor estresse e conseqüentemente menor quantidade de fraturas radiculares, além de não necessitarem da fase laboratorial. A escolha do cimento utilizado para a cimentação desses pinos, tem grande importância e o advento dos cimentos resinosos e dos sistemas adesivos que com eles podem ser empregados, representam uma grande evolução em razão das possibilidades de se obter retenções micromecânicas no interior dos condutos. Assim, o objetivo deste estudo foi avaliar a resistência à extrusão de pinos de fibras de vidro cimentados com cimento resinoso Rely X ARC com a aplicação de três diferentes sistemas adesivos: Scotchbond, Single bond e Adper Prompt LPop. Após a cimentação os espécimes foram seccionados em duas regiões, apical e cervical, que constituía cada uma um corpo de prova. Para possibilitar a realização do teste de extrusão, utilizou-se um dispositivo de aço inoxidável que estabilizava o corpo de prova. Este dispositivo tinha um orifício central que permitia o deslocamento do pino ou do cimento, durante o teste de extrusão. Para o teste de extrusão o corpo de prova foi adaptado no dispositivo com a face cervical voltada para baixo e uma ponta ativa com extremidade plana (1mm de diâmetro) foi adaptada à máquina de ensaios universal que exercia uma força de extrusão o mais próximo possível do centro do pino. O teste foi realizado com um deslocamento de 0,5mm por minuto, onde a carga máxima de falha foi registrada em kgf. No que diz respeito ao cimento resinoso Rely X ARC, em combinação com os adesivos utilizados, os melhores resultados na região cervical da raiz foram obtidos com o cimento Rely X com o sistema adesivo Scotchbond, seguido pelos sistemas Adper Prompt e Single bond. Na região apical o Scotchbond foi melhor que o Adper Prompt e o Single bond, mas não houve diferença estatisticamente significante entre o Adper Prompt e Single bond. / In order to increase strength to fracture of endodontically treated teeth, a number of restorative techniques were developed. Nowadays, carbon and glass fiber post systems are the most used due to their advantages of modulus of lasticity similar to dentin, which lead to lower stress and consequently lower number of root fractures, besides no laboratorial work is needed. The choice of the best cement for luting these posts is an important step and the development of resin cements and adhesive systems that can be use with posts are a great evolution due to the possibility of micromechanical retention in roots. Therefore, the aim of this study was to evaluate extrusion strength of glass fiber posts cemented with resin luting cement Rely X ARC using three different adhesive systems: Scothbond, Single bond and Adper Prompt L Pop. After luting, samples were seccionated in two regions, apical and cervical, each one representing one sample. A stainless steel device was used to perform extrusion test, stabilizing samples. This device had a central orifice that allowed movement of post or cement, during extrusion test. For extrusion test, sample was adapted in the device with cervical face directed to down and a plane surface active point (1 mm diameter) was adapted to the universal test machine which exerted an extrusion force in the center of post. Test was performed with 0.05 mm per minute and the maximum load at failure was registered in kgf. Regarding resin luting cement Rely X ARC combining with adhesive systems, the best results at cervical were obtained with Rely X and Scotchbond adhesive, followed by Adper Prompt and Single bond systems. At apical region Scotchbond was better than Adper Prompt and Single bond, but there was no statistically significant difference between Adper Prompt and Single bond.
37

Resistência de união ao cisalhamento de cimentos resinosos autoadesivos ao esmalte e dentina / Shear bond strength of self-adhesive resin cements to enamel and dentin

Rodrigues, Raphaela Farias 11 March 2013 (has links)
O objetivo deste trabalho foi avaliar a resistência de união ao cisalhamento dos cimentos autoadesivos RelyX U100 (3M/ESPE) e RelyX U200 (3M/ESPE) ao esmalte e à dentina, em função de diferentes tratamentos da superfície e comparando-os com o cimento resinoso RelyX ARC (3M/ESPE). Cento e vinte incisivos bovinos foram selecionados, limpos e armazenados em solução supersaturada de timol 0,1% para evitar a proliferação de micro-organismos. As coroas foram separadas das raízes e incluídas com resina epóxica em tubos de PVC. Utilizaram-se lixas de carbeto de silício, sob refrigeração, para obtenção de superfícies vestibulares planas de esmalte e dentina. Após a delimitação das áreas destinadas à cimentação com fitas autocolantes, a amostra foi distribuída em 12 grupos (n = 10) de acordo com o substrato, cimento e realização ou não do condicionamento com ácido fosfórico 37% em E-U100 (esmalte + RelyX U100), EU100-C (esmalte + RelyX U100 + condicionamento ácido), E-U200 (esmalte + RelyX U200), E-U200-C (esmalte + RelyX U200 + condicionamento ácido), E-ARC (esmalte + adesivo + RelyX ARC), E-ARC-C (esmalte + RelyX ARC + condicionamento ácido e adesivo), D-U100 (dentina + Relyx U100), D-U100-C (dentina + RelyX U100 + condicionamento ácido), D-U200 (dentina + Relyx U200), D-U200-C (dentina + RelyX U200 + condicionamento ácido), D-ARC (dentina + primer e adesivo + RelyX ARC) e D-ARC-C (dentina + RelyX ARC + condicionamento ácido e adesivo). Uma matriz de teflon bipartida (3 mm de diâmetro e 2 mm de altura) permitiu a confecção de cilindros dos cimentos coincidentes com as áreas delimitadas. Os testes de resistência ao cisalhamento foram realizados, após 7 dias de armazenagem em saliva artificial, numa máquina de ensaio universal EMIC, a velocidade de 0,5 mm/min e com célula de carga de 50 kg. A análise da fratura foi realizada por meio do microscópio digital portátil. Com caráter ilustrativo, dois espécimes de cada grupo foram observados em microscopia eletrônica de varredura. Os dados foram analisados pelo teste ANOVA - 3 critérios e teste Tukey (5%). Não se observou diferença entre os cimentos RelyX U100 e RelyX U200. No esmalte, o RelyX ARC apresentou maior resistência do que os autoadesivos, porém com o prévio condicionamento ácido da superfície os autoadesivos mostraram-se superiores. Em dentina, não houve diferença significante entre os grupos. A maioria das fraturas foi do tipo adesiva. Considerando as limitações deste estudo, conclui-se que os cimentos resinosos autoadesivos podem ser utilizados em alternativa aos cimentos resinosos convencionais nas situações com pouca ou nenhuma estrutura em esmalte. Quando houver a presença considerável de esmalte deve-se priorizar o emprego dos cimentos resinosos convencionais ou os autoadesivos associados ao condicionamento com ácido fosfórico previamente à cimentação. / The objective of this study was to evaluate the shear bond strength of selfadhesive cements RelyX U100 (3M/ESPE) and RelyX U200 (3M/ESPE) to enamel and dentin, due to different surface treatments and comparing them with resin cement RelyX ARC (3M/ESPE). One hundred and twenty bovine incisors were selected, cleaned and stored in supersaturated solution of 0.1% thymol to prevent the proliferation of micro-organisms. The crowns were separated from the roots and embedded with epoxy resin in PVC tubes. It was used silicon carbide sandpaper under refrigeration for obtaining flat buccal surfaces of enamel and dentin. After the delimitation of cementations areas with adhesive tape, the sample was distributed into 12 groups (n = 10) under the substrate, cement and conducting or absence of etching with 37% phosphoric acid in E-U100 (enamel + RelyX U100), E-U100-C (enamel + RelyX U100 + etching), E-U200 (enamel + RelyX U200), E-U200-C (enamel + RelyX U200 + etching), E-ARC (enamel + adhesive + RelyX ARC), EARC-C (enamel + RelyX ARC + etching and adhesive), D-U100 (dentin + RelyX U100), D-U100-C (dentin + RelyX U100 + etching), D-U200 (dentin + RelyX U200), D-U200-C (dentin + RelyX U200 + etching), D-ARC (dentin + RelyX ARC + primer and adhesive) and D-ARC-C (dentin + RelyX ARC + etching and adhesive). A split Teflon mold (3 mm diameter and 2 mm height) allowed manufacturing of cement cylinders, which coincide with delimited areas. The shear strength tests were performed after 7 days of storage in artificial saliva, a universal testing machine EMIC, speed 0.5 mm/min and load cell of 50 kg. The analysis of the fracture was performed using the portable digital microscope. With illustrative, two specimens of each group were observed in scanning electron microscopy. Data were analyzed by ANOVA - 3 criteria and Tukey test (5%). No difference was observed between selfadhesive cements RelyX U100 and RelyX U200. In enamel, the RelyX ARC showed higher resistance than the self-adhesive, but with the prior etching of the surface selfadhesive proved superior. In dentine, no significant difference between groups. Most fractures were type adhesive. Considering the limitations of this study it is concluded that the self-adhesive resin cements can be used as an alternative to conventional resin cements in situations with little or no enamel structure. When there is a considerable presence of enamel should prio ritize the employment of conventional resin cements or self-adhesive associated with phosphoric acid etching prior to cementation.
38

Efeito do selamento dentinário imediato na resistência de união de restaurações cerâmicas / Effect of immediate dentin sealing on bond strength of ceramic restorations

Mariana de Andrade Macêdo 16 December 2009 (has links)
O objetivo deste trabalho foi avaliar o efeito do selamento dentinário imediato na cimentação definitiva de restaurações cerâmicas (Empress2Ivoclar Vivadent), levando em consideração a influência de diferentes métodos de remoção dos restos de cimento provisório da superfície dentinária previamente selada. Para isso foram utilizados 72 molares, hígidos, conseguidos no banco de dentes da Universidade do Estado do Rio de Janeiro. Os dentes foram divididos em nove grupos, os três primeiros serviram como grupo controle, onde não houve contaminação com nenhum cimento provisório, sendo eles: G1, onde o selamento e a cimentação definitiva foram feitas 15 dias após a confecção dos preparos cavitários; G2, onde o selamento dentinário foi feito imediatamente após o preparo e a cimentação definitiva após 15 dias; G3, onde o preparo, selamento e cimentação definitiva foram feitos no mesmo momento. Os próximos grupos foram os do selamento tardio, onde o sistema adesivo foi aplicado somente no momento da cimentação. Nestes grupos, após o preparo foram cimentadas restaurações provisórias com um cimento livre de eugenol (Temp BondNE) e após 15 dias as restaurações provisórias foram removidas e os restos de cimento limpos com diferentes métodos: G4: remoção com instrumento manual; G5: remoção com jato de bicarbonato; G6: remoção com pontas de ultra-som; após esta limpeza o sistema adesivo foi aplicado e as restaurações cerâmicas cimentadas. Por último foram os grupos do selamento dentinário imediato, onde o sistema adesivo foi aplicado imediatamente após a confecção dos preparos cavitários e em seguida foi feita a cimentação das restaurações provisórias. Após 15 dias as restaurações provisórias foram removidas, os restos de cimento foram limpos com os diferentes métodos: G7: remoção com instrumento manual; G8: remoção com jato de bicarbonato; G9: remoção com pontas de ultra-som. Após a limpeza as restaurações cerâmicas foram cimentadas. Para todos os grupos o sistema adesivo utilizado foi o Optibond FL Kerr e o cimento resinoso foi o Rely X ARC3M/ESPE. Vinte e quatro horas após as cimentações cerâmicas os corpos de prova foram submetidos ao ensaio mecânico de push out em uma máquina de ensaios universais EMIC DL. Os valores de resistência de união foram obtidos em KgF, convertidos em MPa e analisados estatisticamente. O teste de ANOVA mostrou que houve diferença estatisticamente significante entre os grupos (p&#8804;0,05) e em seguida o t-teste mostrou que a técnica do selamento imediato resultou nos melhores valores de resistência de união. Por último, o teste de comparações múltiplas Student-Newman-Keuls (Teste SNK) mostrou que o método de limpeza dos restos de cimento provisório da superfície dentinária apresenta influência na resistência de união das restaurações cerâmicas. Com base nos resultados pôde-se concluir que a técnica do selamento imediato promoveu maior resistência adesiva para as restaurações cerâmicas e quanto ao método de limpeza, o melhor resultado, independente da técnica adesiva utilizada, foi a remoção com as pontas de ultrasson. / The aim of this study was to evaluate the effect of immediate dentin sealing on bond strength of ceramic restorations, taking into account the influence of different techniques used to remove temporary cement remainings from dentin surfaces. Seventy two intacts and caries free human molars were taken from UERJ teeth bank in order to perform the necessary experiments. They were divided into nine groups. The first three groups served as control groups and there was no contamination with temporary cements: G1, the dentin sealing and ceramic cementation were made fifteen days after preparation; G2, the dentin was sealed immediately after preparation and after fifteen days the ceramic restorations were fixed; G3, wich the praparation, dentin sealing and ceramic cementation were made at the same time. The next three groups constituted the delayed dentin sealing group, where the dentin bonding agent were applied only in the moment of ceramic cementation. After preparation, provisional restorations were placed with a provisional cement without eugenol (Temp BondNE) and after fifteen days they were removed and dentin surfaces were cleaned by differents methods: G4: hand instrument; G5: sodium bicarbonate jet; G6: ultra-sonic scaler. The adhesive system was then applied and the ceramics were bonded. The three last groups constituted the immediate dentin sealing, where the dentin bonding agent was applied immediately after preparation, before provisional cementation. Following fifteen days, the provisional restorations were removed and the sealed dentin were cleaned by differents methods: G7: hand instrument; G8: sodium bicarbonate jet; G9: ultra-sonic scaler. After these procedures the ceramic restorations were bonded. The adhesive system used in all groups was Optibond Kerr and the resin cement was Rely X ARC3M/ESPE. Following twenty four hours all specimens were submitted to the push-out test in a universal testing machine EMIC DL. The push out bond strength was obtained in KgF and were then converted into MPa. The results were analysed: one-way ANOVA revealed significant differences between groups (p&#8804;0,05), t-test showed that immediate dentin sealing provided the highest values of bond strength. At least, the Multiple comparisions SNK Test detected that the differents techniques used to remove temporary cement remainings from dentin surfaces had an influence on the ceramic bond strength, and even when immediate dentin sealing or delayed dentin sealing was used, the ultra-sonic scaler showed the better results.
39

Influência da atenuação da luz provocada por materiais restauradores indiretos estéticos sobre a polimerização de um cimento resinoso / Influence of the light attenuation caused by aesthetic indirect restoration materials on the polymerization of a resin cement.

Pick, Bárbara 03 July 2007 (has links)
Objetivo: O objetivo desta pesquisa foi verificar o efeito da interposição de diferentes materiais restauradores indiretos na resistência à flexão em três pontos (RF), microdureza Knoop (MK) e grau de conversão FT-Raman (GC) de um cimento resinoso. Material e métodos: Os materiais restauradores indiretos selecionados para a confecção dos discos (2 mm de espessura e 11 mm de diâmetro) foram: a vitrocerâmica IPS Eris/Ivoclar-Vivadent (E); a cerâmica de infra-estrutura IPS Empress 2/Ivoclar-Vivadent recoberta pela vitrocerâmica IPS Eris/Ivoclar-Vivadent (EE); a resina composta microhíbrida Sinfony/3M ESPE (S); a resina composta microparticulada SR Adoro/Ivoclar-Vivadent (A). Inicialmente, foi determinada a transmitância relativa (TR) destes materiais restauradores através da análise de imagens digitais obtidas por uma câmera CCD e de um espectrômetro de luz visível. Em seguida, os corpos-de-prova (cps, 10 x 2 x 1 mm) do cimento resinoso Nexus 2/SDS Kerr, com (dual) e sem catalisador (fotoativado), foram polimerizados sob os discos de materiais restauradores indiretos utilizando o aparelho de fotoativação de luz halógena OptiluxTM 501/SDS Kerr (QTH) ou o diodo emissor de luz L.E.Demetron 1/SDS Kerr (LED). Os cps também foram fotoativados sem a interposição dos discos, deixando um espaço de zero (E0) e dois (E2) mm entre a ponta do fotoativador e a superfície do cimento. Para avaliação da MK e GC, cada cp foi dividido em quatro zonas: face irradiada - centro (IC); irradiada - borda (IB); não-irradiada - centro (NC); não-irradiada ? borda (NB). Além disso, foi avaliada a emissão espectral dos dois aparelhos de fotoativação com valores de irradiância relativa (%) e absoluta (mW/cm2). Resultados: A espectrometria foi o método mais sensível para detectar diferenças de TR entre os materiais restauradores e detectou que a resina S (3,5%a) transmitiu mais luz e a cerâmica E transmitiu menos luz (1,6%c). A análise de variância mostrou que o cimento dual apresentou médias superiores (P<0,001) de RF (201,3MPa), MK (42,3KHN) e GC (74,8%) em relação ao fotoativado. E, que o QTH (191,5MPaa) promoveu média de RF superior (P<0,001) em relação ao LED (164,4MPab). Em contrapartida, o LED aumentou os valores de MK do cimento em algumas interações e em outras não houve diferença estatística entre os aparelhos. O método FT-Raman apresentou uma menor sensibilidade do que o ensaio de MK para detectar diferenças entre os grupos experimentais. A interposição dos discos de cerâmica reduziu significativamente a RF e MK do cimento fotoativado em relação aos grupos E0 e E2, no entanto, quando foi adicionado o catalisador ao cimento estas reduções não ocorreram. A zona IC (39,6KHNa) dos cps apresentou maiores médias de MK e a zona NB (34,6KHNc) as menores, evidenciando a distribuição não-uniforme da luz sobre o cp. Foi verificado ainda uma correlação positiva entre as médias de GC e MK. Conclusão: A partir dos resultados desta pesquisa concluiu-se que houve uma tendência na qual os materiais restauradores que transmitiram mais luz ao cimento resinoso, principalmente o de pasta única (fotoativado), lhe proporcionou melhores condições para uma reação de polimerização mais eficiente e,consequentemente, propriedades físicas máximas. / Objective: The aim of this study was to verify the effect of interposing different indirect restorative materials on the three-point flexural strength (FS), Knoop microhardness (KHN) and FT-Raman degree of conversion (DC) of a resin cement. Methods: Disks (2-mm thick and 11- mm in diameter) were built using the indirect restorative materials IPS Eris (Ivoclar-Vivadent glass-ceramic, E), IPS Empress 2 (Ivoclar-Vivadent framework ceramic) veneered by IPS Eris (EE), Sinfony (3M ESPE, micro-hybrid composite resin, S) and SR Adoro (Ivoclar-Vivadent microfilled composite resin, A). Initially, their relative transmittance (RT) was determined analyzing digital images obtained by a CCD camera and with visible light spectrometry. Then, bar-shaped specimens (sps, 10 x 2 x 1 mm) of the Nexus 2 resin cement (SDS Kerr) were prepared either with (dual) or without catalyst (light-cured), and photoactivated throught the different restorative materials disks using a halogen light curing unit (QTH, OptiluxTM 501, SDS Kerr) or a light emitting diode (LED, L.E.Demetron 1, SDS Kerr). The sps were also light-cured without interposing the disks, keeping the curing unit light guide either in contact (S0) or 2 mm (S2) from the cement surface. For KHN and DC evaluation, each sp was divided in four regions: irradiated-center (IC), irradiated-edge (IE), non-irradiated-center (NC) and non-irradiated-edge (NE). Light curing unit spectral emissions were obtained with the relative (%) and absolute (mW/cm2) irradiance values. Results: The spetrometry was more capable to detect the RT differences between the restoration materials than the CCD camera and indicated that the S resin (3,5%a) transmitted more light and the E ceramic (1,6%c) transmitted less light. ANOVA revealed higher FS, KHN and DC values for the cement in dual-cure mode compared to light-cure (p<0.001). The QTH (192 MPaa) promoted higher FS than LED (164 MPab). On the other hand, the LED increased the KHN values in some interactions with the EE group and in other interactions there were not statistic differences between the curing units. The FT-Raman method was less sensitive than KHN to detect differences between the experimental groups. The ceramic materials reduced the light-cured cement?s FS and KHN compared to the S0 and S2 groups; however, when the catalyst was added to the cement these reductions did not occurred. The IC regions showed the highest KHN values and the NE, the lowest, indicating the non-uniform distribution of the light. A positive correlation was found between DC and KHN. Conclusion: It was possible to conclude that there was a tendency for the restorative materials which allowed more light transmission to provided better conditions for an efficient polymerization reaction and, consequently, desirable physical properties of the resin cement, more noticeable when used in light-cure mode.
40

Endodontic sealers their properties and effects on fiber post retention /

Najib, Farrah Huthail. January 2008 (has links) (PDF)
Thesis (M.S.)--University of Alabama at Birmingham, 2008. / Title from first page of PDF file (viewed Feb. 16, 2009). Includes bibliographical references (p. 49-57).

Page generated in 0.0574 seconds