• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 117
  • 13
  • 8
  • 3
  • 1
  • 1
  • Tagged with
  • 149
  • 149
  • 120
  • 91
  • 72
  • 46
  • 43
  • 36
  • 33
  • 32
  • 32
  • 29
  • 29
  • 29
  • 27
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Effect of Al [subscript 2] O [subscript 2] core on the polymerization of a resin cement a thesis submitted in partial fulfillment ... for the degree of Master of Science in Restorative Dentistry Master of Science in Prosthodontics ... /

Aleman, Marjorie. January 2003 (has links)
Thesis (M.S.)--University of Michigan, 2003. / Includes bibliographical references.
42

Análise da qualidade de polimerização, por meio de testes de microdureza, de um cimento resinoso utilizado na cimentação de coroas totais em preparos com diferentes substratos / Analysis of quality of polymerization of a resin cement used to cement ceramic crowns in differents preparation substrates through microhardness tests

Luana Menezes de Mendonça 27 May 2011 (has links)
O objetivo deste estudo foi avaliar a microdureza do cimento resinoso Variolink II ( Ivoclar Vivadent, Schaan, Liechtenstein) empregado na cimentação de coroas totais de cerâmica (IPS e.max Press, Ivoclar Vivadent, Schaan, Liechtenstein) em preparos com 3 substratos (dentina, metal e resina composta). Foram utilizados 30 molares distribuídos em 3 grupos de acordo com o tipo de substrato. No grupo com substrato em dentina (D), as coroas foram cimentadas em dentes preparados em dentina. Nos grupos com substrato em metal (M) e resina (R), as coroas foram seccionadas no nível da junção cemento-esmalte e restauradas com núcleos metálicos e de preenchimento em resina composta, respectivamente. Cada um dos grupos foi subdividido em subgrupos para avaliação após 7 dias e 3 meses de armazenamento em água deionizada. Os espécimes foram seccionados no centro das coroas, no sentido vestíbulo-lingual e as superfícies foram polidas para a realização dos testes de microdureza ao longo da linha de cimento. Os valores de microdureza foram obtidos nos terços cervical, médio, oclusal das faces vestibular e lingual e na face oclusal. Os resultados foram submetidos a uma análise estatística prévia ANOVA a 3 critérios (substratos/ armazenamento/ terços e face oclusal), a qual não mostrou diferenças significativas entre os terços e face oclusal nos 2 períodos de armazenamento. Em seguida foi realizada a ANOVA a 2 critérios (substrato e armazenamento) e o teste de Tukey que mostraram os resultados do substrato em resina estatisticamente inferiores aos de dentina e metal, após o período de armazenamento de 7 dias. Conclui-se que a microdureza do cimento resinoso não variou nos diferentes terços e face e que a influência do substrato em resina no cimento foi tempo-dependente. / The aim of this study was to evaluate the microhardness of resin cement Variolink II (Ivoclar Vivadent, Schaan, Liechtenstein) used to cement full ceramic crowns (IPS e.max Press, Ivoclar Vivadent, Schaan, Liechtenstein) in three preparations substrates (dentin, metal and composite resin). Thirty molars were divided into three groups, according to the type of the substrate. In the dentin substrate group (D), the crowns were prepared in dentin; the metal (M) and resin (R) substrates groups, the crowns were sectioned at cement enamel junction level and restored with metal cast post and composite resin filler, respectively. Each group was subdivided into subgroups to evaluation after 7 days and 3 months of storage in deionized water. After cementing the specimens were sectioned buccolingually at the center of the crowns, and the surfaces were polished to microhardness test along the cement line. The microhardness values were obtained in the cervical, medium and occlusion thirds of the buccal and lingual surfaces and in the occlusal surface. The results were submitted to a three-way ANOVA (substrates / storage / thirds and occlusal surface) to a prior statistical analysis and did not show significant differences between the occlusal surface and thirds in the two storage periods. Then two-way ANOVA (substrate and storage) and the Tukey test were performed. The results in the resin group were statistically lower than those of dentin and metal, after 7 days of storage. Therefore, the microhardness of resin cement did not change in the different thirds and face and that the influence of the resin substrate was time-dependent.
43

Nanotubos de nitreto de boro como carga para resinas adesivas

Degrazia, Felipe Weidenbach January 2017 (has links)
O objetivo do presente estudo foi desenvolver e avaliar a incorporação de nanotubos de Nitreto de Boro (BNNT) como carga em uma resina adesiva. Foi formulada uma resina adesiva utilizando-se os seguintes reagentes: 2- hidróxietil metacrilato (HEMA), Bisfenol A glicol dimetacrilato (BisGMA), canforoquinona (CQ) e Etil 4-dimetilaminobenzoato (EDAB). Os BNNTs foram caracterizados por Microscopia Eletrônica de Varredura (MEV) e Microscopia Eletrônica de Transmissão (MET). O adesivo experimental com diferentes concentrações de BNNT (0, 0,05, 0,075, 0,1 e 0,15%) foi caracterizado quanto ao ângulo de contato e energia livre de superfície (ELS), dureza e amolecimento em solvente (solução de etanol) em microdurômetro, deposição mineral até 14 dias e grau de conversão por espectroscopia Raman e resistência coesiva. O adesivo experimental com diferentes concentrações de BNNT após imersão por 3 h em 65% HNO3 e 48 h em H2O2 foi caracterizado por grau de conversão e cinética de polimerização por Espectroscopia de infravermelho por transformada de Fourier (FTIR), ângulo de contato em dentina por tensiômetro, citotoxicidade por sulforodamina B (SRB) e resistência de união imediata e longitudinal Os resultados da análise de microscopia eletrônica de varredura e de transmissão demonstraram nanotubos de nitreto de boro com diâmetros de 5 a 10 nanometros com término fechado. Nenhuma modificação no grau de conversão ocorreu após a incorporação de BNNTs até 0,15%. Os ângulos de contato de água e α-bromonaftaleno aumentaram (p < 0,05) e consequentemente a ELS diminuiu após a incorporação de BNNTs ao adesivo. Houve aumento da microdureza e da resistência ao amolecimento em solvente após incorporação de 0,075, 0,1 e 0,15% de BNNTs. Não houve diferença significativa na resistência coesiva entre os diferentes grupos. Foi encontrada deposição mineral nos espécimes com BNNT após sete dias de imersão em SBF (fluido corporal simulado). Após o tratamento dos BNNTs com HNO3 e H2O2 e incorporação ao adesivo, houve aumento do grau de conversão e da taxa de polimerização máxima após incorporação de 0,075 e 0,1% de BNNT. O ângulo de contato à dentina aumentou após a incorporação de 0,15% BNNT. Não houve diferença significativa na resistência de união entre os grupos após 24 h (p >0,05). Após 6 meses a resistência de união diminuiu significativamente para o grupo 0% e 0,15% BNNT. Entretanto, os grupos que tiveram incorporação de BNNT obtiveram maiores valores que 0% (p <0,05). Não houve diferença no crescimento celular (p >0,05) entre os grupos em comparação ao grupo controle positivo (100% de crescimento). A incorporação de BNNT até 0,15% melhorou as propriedades físico-químicas do adesivo dentário, promoveu deposição mineral e aumentou a estabilidade longitudinal sem apresentar citotoxicidade a fibroblastos, fornecendo benefícios consideráveis frente aos materiais disponíveis no mercado. / The aim of this study was to develop and evaluate the incorporation of boron nitride nanotubes (BNNTs) into an adhesive resin. An adhesive resin was developed using the following reagents: 2-hydroxyethyl methacrylate (HEMA), bisphenol-A glycidyl dimethacrylate (BisGMA), camphorquinone (CQ) e ethyl 4- dimethylaminobenzoate (EDAB). BNNTs were characterized by Scanning Electron Microscopy (SEM) and Transmission Electron Microscopy (TEM). The experimental adhesive with different concentrations of BNNT (0, 0.05, 0.075, 0.1 e 0.15%) was characterized by contact angle and surface free energy (SFE), hardness and softening in solvent (ethanol solution) by microdurometer, mineral deposition up to 14 days and degree of conversion by Raman spectroscopy and ultimate tensile strength test. The experimental adhesive with different concentrations of BNNT after immersion for 3 h in 65% HNO3 and 48 h in H2O2 was characterized by degree of conversion and polymerization kinetics by Fourier Transform Infrared Spectroscopy (FTIR), contact angle in dentin by tensiometer, sulforhodamine B (SRB) cytotoxicity and immediate and longitudinal bond strength. The results of scanning and transmission electron microscopy showed boron nitride nanotubes with diameters of 5 to 10 nanometers with closed end tips No change in degree of conversion occurred after the incorporation of BNNTs up to 0.15%. The contact angles of water and α-bromonaphthalene increased (p <0.05) and consequently SFE decreased after the incorporation of BNNTs to adhesive. After incorporation of 0.075, 0.1 and 0.15% BNNTs an increase was shown in microhardness and resistance to softening in solvent. No significant difference in ultimate tensile strength was found among groups. Mineral deposition was found on BNNT specimens after seven days of immersion in SBF (simulated body fluid). After BNNTs´ treatment with HNO3 and H2O2 and incorporation into the adhesive, there was an increase in the degree of conversion and the maximum polymerization rate after incorporation of 0.075 and 0.1% of BNNT. Contact angle in dentin increased after incorporation of 0.15% BNNT. There was no significant difference in microtensile bond strength among groups after 24 h (p> 0.05). After 6 months the bond strength decreased significantly for 0% group and 0.15% BNNT. However, the groups that had BNNT incorporation obtained higher values than 0% (p <0.05). There was no difference in cell growth (p> 0.05) among groups compared to the positive control group (100% growth). The incorporation of BNNT up to 0.15% improved the physicochemical properties of dental adhesive, promoted mineral deposition and increased longitudinal stability with no cytotoxicity to fibroblasts, providing considerable benefits against dental materials available in the market.
44

Resistência de união de cimentos resinosos, convencional e autoadesivo, em substratos dentinários normal e hipermineralizado artificalmente / Bond strength of resin, conventional and self-adhesive cements, under normal dentin substrates and sclerotic artificially

Tavares, Maria Tereza Gomes [UNESP] 21 March 2016 (has links)
Submitted by MARIA TEREZA GOMES TAVARES null (mariatereza_t@hotmail.com) on 2016-04-04T12:44:42Z No. of bitstreams: 1 Dissertação Maria Tereza.pdf: 2059134 bytes, checksum: 54c1a762e9d937d867d45018734397ae (MD5) / Approved for entry into archive by Juliano Benedito Ferreira (julianoferreira@reitoria.unesp.br) on 2016-04-05T18:59:26Z (GMT) No. of bitstreams: 1 tavares_mtg_me_arafo.pdf: 2059134 bytes, checksum: 54c1a762e9d937d867d45018734397ae (MD5) / Made available in DSpace on 2016-04-05T18:59:27Z (GMT). No. of bitstreams: 1 tavares_mtg_me_arafo.pdf: 2059134 bytes, checksum: 54c1a762e9d937d867d45018734397ae (MD5) Previous issue date: 2016-03-21 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste trabalho foi avaliar a resistência de união de cimentos resinosos, convencional e autoadesivo, em um substrato dentinário normal e hipermineralizado artificialmente. Sessenta e seis (N=67) molares humanos hígidos, doados pelo Banco de Dentes da Faculdade de Odontologia de Araraquara, foram selecionados e divididos aleatoriamente, de acordo com o tipo de substrato dentinário: normal (n= 33) e hipermineralizado artificialmente (n=34). Em seguida o grupo de substrato dentinário normal foi subdividido em N-ARC, N-U200 e N-AC+U200 de acordo com o tipo de protocolo de cimentação: RelyX™ ARC, RelyX™ U200 e condicionamento adicional com ácido fosfórico 37% por 15” + RelyX™ U200; e o de substrato hipermineralizado artificialmente foi subdividido em H-ARC, H-U200 e H-AC+U200 seguindo o mesmo protocolo de cimentação. Um (n=1) espécime de cada grupo foi submetido a análise de microscopia eletrônica de varredura (MEV). As cimentações dos cilindros foram realizadas com a ajuda de uma matriz bipartida de teflon. Após período de armazenagem em ambiente úmido por 24 horas a 37°C, os espécimes foram adaptados a um dispositivo para o teste de resistência de união ao microcisalhamento. A análise estatística utilizada foi Two-way ANOVA/Tukey. Não foram encontradas diferença estatística entre os substratos dentinários e os protocolos de cimentação. O cimento resinoso RelyX ARC apresentou maiores valores de resistência de união (N-ARC=77,60 e H-ARC=68,40), independente do substrato. O padrão de fratura predominante foi do tipo adesiva. As imagens de microscopia mostraram que os cimento autoadesivo RelyX U200 é incapaz de formar camada híbrida. Conclui-se que o cimento autoadesivo apresenta resistência de união ao microcisalhamento semelhante ao cimento convencional, independente do substrato dentinário ser normal ou hipermineralizado artificialmente. / The objective of this study was to evaluate the bond strength of resin, conventional and self-adhesive cements, in a normal dentin and sclerotic artificially. Sixty-six (N = 66) human molars, donated by Teeth Bank of Araraquara Dental School, were selected and randomly divided according to the type of dentin: normal (n = 33) and sclerotic artificially (n = 33). Then normal dentin group was subdivided into N ARC, N-U200 and N-AC + U200 in accordance with the type of cementing protocol: RelyX ™ ARC RelyX ™ U200 and additional conditioning with phosphoric acid 37% by 15 "+ RelyX ™ U200; and the sclerotic substrate was artificially subdivided into M-ARC M-H U200 and U200 AC + following the same protocol cementing. A (n = 1) specimen from each group was subjected to analysis of scanning electron microscopy (SEM). The cementing was carried out with the aid of a metallic mold Teflon. After the storage period in a humid environment for 24 hours at 37 ° C, the specimens were adapted to a device for testing the bond strength of the microshear. The statistical analysis used was Two-way ANOVA / Tukey. There were no statistical difference between the dentinal substrates and cementation protocols. The resin cement RelyX ARC showed higher bond strength values (N = 77.60 ARC and ARC-H = 68.40), regardless of the substrate. The pattern of prevalent fracture was of adhesive type of cement and dentin. The microscopy images showed that the selfadhesive cement RelyX U200 is unable to form hybrid layer. It follows that the selfadhesive cement bond strength has to microshear similar to conventional cement, independent of the substrate normal or sclerotic dentin be artificially.
45

Influência do sistema de cimentação adesiva e da fonte de luz fotoativadora na resistência à extrusão de pinos de fibra de vidro

Lima, Luiz Rafael Calixto [UNESP] 03 March 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-03-03Bitstream added on 2014-06-13T18:51:40Z : No. of bitstreams: 1 lima_lrc_me_arafo.pdf: 301269 bytes, checksum: e249a410590b65d0ca0f202c5160930d (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A retenção de pinos pré-fabricados de fibra de vidro, utilizados na restauração de dentes com tratamento endodôntico, é baseada na sua união às superfícies das paredes do canal radicular, por meio dos agentes de fixação resinosos. O tipo de pino utilizado, assim como a fonte de luz fotoativadora do cimento, também pode influenciar nessa retenção, principalmente nas regiões mais críticas do canal, como o terço apical, onde há uma grande dificuldade de acesso dessa luz ativadora. Assim, o propósito deste trabalho foi avaliar comparativamente a influência de diferentes sistemas de cimentação (químico convencional; dual convencional, químico com adesivo auto-condicionante, dual com adesivo auto-condicionante e cimento dual auto-adesivo), na resistência à extrusão (push-out) de pinos de fibra de vidro, nos diferentes terços do canal (cervical, médio, aplical). Foi avaliada também a influência do tipo de fonte de luz fotoativadora do cimento: luz halógena (Optilux 501) e LED (Ultraled). O tipo de falha foi avaliado através de microscopia. Foram utilizadas 240 unidades experimentais, em forma de discos, com aproximadamente 1 mm de espessura, retirados de 80 raízes bovinas, restauradas com retentores intraradiculares. Foi utilizada uma máquina de ensaios universais, MTS 810 Material Test System, à velocidade de 0,5 mm/min-1, com célula de carga de 50 Kg, para avaliação da resistência push-out nos diferentes terços de cada corpo-de-prova. Os valores de resistência em kgf, foram convertidos para MPa e analisados por meio de Análise de Variância e teste de Tukey, com nível de significância de 5%. Os resultados mostraram baixos valores de retenção para os grupos com os cimentos autoadesivos,independente da fonte de luz utilizada. Os cimentos de condicionamento ácido total e os de adesivos auto-condicionantes parecem ser opções viáveis no processo... / The retention of prefabricated glass fiber posts, used for the restoration of endodontically-treated teeth, is based on adhesive systems and resin luting cements. The type of posts used, as well as the type of activation of the cement can also influence this retention, mainly in more critical areas of the radicular dentin, such as the apical root segments, where there is a great difficult access of the light curing units. Thus, the purpose of this study was to evaluate the influence of different resin cements (Chemical-cure total-etch; dual-cure total-etch; chemicalcure and self-etch bonding system, dual-cured and self-etch bonding system; and dual-cure self-adhesive cement) on the bond strength (push-out) of glass fiber posts on the different thirds of the root (cervical, middle and apical). The influence of the light curing unit was evaluated by halogen LCU (Optilux 501) and by LED LCU (LEC II 470) use. The failure mode was evaluated by stereoscopic microscope. Disks of the samples (n=240) were used, with approximately 1 mm of thickness of 80 bovine roots restored with glass fiber posts. A universal testing machine (MTS 810 Material Test System) was used with a 1 mm diameter steel rod at cross-head speed of 0,5 mm/min until post extrusion, with load cell of 50 kg, for evaluation of the push-out strength in different thirds of each sample. The pushout strength values in kgf were converted to MPa and analyzed through Analysis of Variance and Tukey’s test, with significant level of 5%. The results of the present study showed that the self-adhesive cements group resulted in low retention values, in every light source utilized. The total-etch cements and the self-etch bonding systems seem to be a viable alternative in the glass fiber posts cementation process, with either halogen light or LEDs.
46

Efeito da aplicação e fotoativação prévia de sistemas adesivos em cerâmica de dissilicato de lítio: análise da resistência de união e das propriedades mecânicas dos componentes resinosos da interface adesiva / Effect of the application and photocuring of adhesive systems on lithium dissilicate ceramics: analysis of the bonding strength and mechanical properties of resin components of the adhesive interface

Proni, Ana Teresa Maluly [UNESP] 10 August 2017 (has links)
Submitted by ANA TERESA MALULY PRONI null (atmaluly@gmail.com) on 2017-08-23T23:42:10Z No. of bitstreams: 1 Dissertação final PG.pdf: 11739184 bytes, checksum: c29a110c8218312fa826f50a4756d1d4 (MD5) / Approved for entry into archive by Luiz Galeffi (luizgaleffi@gmail.com) on 2017-08-25T14:07:17Z (GMT) No. of bitstreams: 1 proni_atm_me_araca.pdf: 11739184 bytes, checksum: c29a110c8218312fa826f50a4756d1d4 (MD5) / Made available in DSpace on 2017-08-25T14:07:18Z (GMT). No. of bitstreams: 1 proni_atm_me_araca.pdf: 11739184 bytes, checksum: c29a110c8218312fa826f50a4756d1d4 (MD5) Previous issue date: 2017-08-10 / O objetivo deste estudo foi analisar o efeito da aplicação e da fotoativação prévia de diferentes sistemas adesivos em superfície de cerâmica de dissilicato de lítio, com ênfase na resistência da união cimento-cerâmica e na análise das propriedades mecânicas nanodureza e módulo de elasticidade dos diferentes adesivos e do cimento resinoso utilizado. Quarenta e nove blocos de resina composta (Z350XT A6B) e de blocos cerâmicos (e.max CAD LT D3) foram divididos em sete grupos experimentais (n=7), os quais foram cimentados entre si de acordo com o sistema adesivo utilizado na superfície dos blocos cerâmicos: Grupo 1: sem adesivo; Grupo 2: Adper™ Scotchbond™ Multi-Purpose Adhesive (SBMP) sem fotoativação; Grupo 3: SBMP com fotoativação; Grupo 4: Adper™ Single Bond 2 (SB2) sem fotoativação; Grupo 5: SB2 com fotoativação; Grupo 6: Single Bond Universal (SBU) sem fotoativação; Grupo 7: SBU com fotoativação. Em todos os grupos experimentais, o cimento resinono utilizado foi o RelyX Ultimate. Após 24 horas do processo de cimentação, todos os conjuntos foram submetidos à termociclagem entre 5°C e 55°C, com tempo de permanência de 28 segundos e tempo de transferência de 2 segundos para envelhecimento (10.000 ciclos). Os conjuntos foram então seccionados para obtenção de palitos para análise da resistência de união e das propriedades mecânicas de nanodureza e módulo de elasticidade dos adesivos e do cimento resinoso utilizado. Os dados foram submetidos à ANOVA e teste de Fisher (α = 0,05). Os resultados mostraram que os grupos SBMP e SB2 sem fotoativação apresentaram os menores valores de resistência de união, enquanto que para as propriedades mecânicas de nanodureza e módulo de elasticidade os maiores valores foram encontrados somente para o grupo SBMP com fotoativação, mostrando que a resistência de união foi influenciada pela interação dos materiais utilizados. Para as propriedades mecânicas analisadas, a fotoativação prévia dos sistemas adesivos não apresentou diferença estatisticamente significante na comparação entre os grupos. De acordo com os resultados obtidos, concluiu-se que a aplicação de sistemas adesivos na superfície silanizada da cerâmica se mostrou desnecessária. Dentre os adesivos estudados, o SBU foi o único material que se mostrou eficaz com ou sem fotoativação prévia. Para os demais adesivos estudados, SBMP e SB2, a fotoativação prévia se mostrou necessária para otimizar a resistência de união da interface adesiva estudada. / The aim of this study was to analyze the effect of the application and previous photoactivation of different adhesive systems on lithium dissilicate ceramics, with emphasis on the bond strength of cement-ceramic interface and the analysis of the mechanical properties (nanohardness and elastic modulus) of different adhesives systems and resin cement used. Forty-nine composite resin blocks (Z350XT A6B) and ceramic tablets (e.max CAD LT D3) which were divided into seven experimental groups (n = 7), according to the adhesive systems and photoactivation techniques of the materials inside the ceramic crown: Group 1: control (without adhesive system); Group 2: SBMP with no light-curing; Group 3: light-cured SBMP; Group 4: SB2 with no light-curing; Group 5: light-cured SB2; Group 6: SBU with no light-curing; Group 7: light-cured SBU. After the luting procedure with RelyX Ultimate, all specimens were submitted to thermocycling procedure (10,000 cycles). Sticks were then obtained for the analysis of microtensile bonding strength and nanohardness and elastic modulus of the resin componentes of the adhesive interface. Data were submitted to statistical analysis (ANOVA) and Fisher's test (α = 0.05). The results showed that the SBMP with no light-curing and SB2 with no light-curing groups had the lowest values ​​of bonding strength, while the highest values of the mechanical properties were achieved for the light-cured SBMP group, showing that the bonding strength as well as the mechanical properties were influenced by the interaction of materials. For mechanical properties analyzed, the light-curing of the adhesive systems didn’t present a statistically significant diference in the comparison between groups. In general, the application of adhesive systems on the silanized ceramic surface showed needless. Among the adhesives studied, SBU was the only system that showed effectiveness with or without previous light activation. For the other adhesive systems, SBMP and SB2, the previous light activation was necessary to optimize the bonding strength of the adhesive interface.
47

Avaliação da eficácia de primers para metal na resistência ao cisalhamento da união entre cimentos resinosos e metais não nobres. Efeito do armazenamento em água /

Fonseca, Renata Garcia. January 2008 (has links)
Resumo: O sucesso das restaurações metálicas indiretas depende, dentre outros fatores, de uma união eficaz entre a estrutura metálica e o cimento dentário empregados. Sabe-se que os primers para metal atuam com comprovada eficácia na resistência adesiva dos cimentos resinosos às ligas nobres. Entretanto, pouco foi estudado sobre o efeito de tais materiais em ligas não nobres. O propósito deste estudo foi avaliar a eficácia de primers para metal na resistência ao cisalhamento da união entre cimentos resinosos e metais não nobres. Discos (9 mm de diâmetro e 3 mm de altura) foram fundidos em liga de NiCr (n=80) e em titânio comercialmente puro (Ti c.p.) (n=80) e foram incluídos em anel de PVC com resina acrílica quimicamente ativada. As superfícies dos discos foram regularizadas com lixas de carbeto de silício de granulação 320, 400 e 600 e jateadas com partículas de óxido de alumínio de 50 µm. Espécimes de cada metal foram divididos em quatro grupos (n=20). Uma matriz metálica bi-partida (5 mm de diâmetro interno e 2 mm de altura) foi posicionada na superfície do espécime. As áreas adesivas receberam um dos seguintes tratamentos: 1) Panavia F; 2) Alloy Primer e Panavia F; 3) Bistite DC e 4) Metaltite e Bistite DC. Para evitar a exposição dos cimentos à luz, estes foram espatulados e inseridos na matriz dentro de uma câmara de revelação radiográfica. Quarenta minutos após a confecção, os espécimes foram armazenados em água destilada a 37ºC por 24 horas e então termociclados (1.000 ciclos, 5ºC e 55ºC, 30 segundos cada banho). Após a termociclagem, os espécimes foram armazenados novamente nas mesmas condições descritas anteriormente por um período de 24 horas (n=10) ou de 6 meses (n=10) antes do ensaio de cisalhamento em uma máquina de ensaios mecânicos (Material Test System 810). / Abstract: A successful indirect metallic restoration depends, among other factors, on an effective bonding between metal framework and dental cements. There is scientific evidence that metal primers work effectively on adhesive bonding of resin cements to noble alloys. However, there are few studies about the effect of these primers on base metal alloys. The purpose of this study was to evaluate the efficacy of metal primers on shear bond strength of resin cements to base metals. Discs specimens (9 mm diameter and 3 mm thick) were cast from nickel-chromium alloy (n=80) and pure titanium (CP Ti) (n=80), and were embedded in a polyvinyl chloride ring, using polymethyl methacrylate acrylic resin. All specimen bonding surfaces were smoothed with 320-, 400- and 600-grit silicon carbide paper, and airborne-particle abraded with 50 µm aluminum oxide. Specimens for each metal was divided into 4 groups (n=20). A custom-made metal matrix (5.0 mm internal diameter and 2.0 mm thick) was placed on the surface of the specimen. The bonding sites received 1 of the following treatments: 1) Panavia F; 2) Alloy Primer plus Panavia F; 3) Bistite DC and 4) Metaltite plus Bistite DC. To avoid exposure of the resin cements to daylight, they were mixed and inserted into the matrix inside a radiographic developing chamber. Forty minutes after preparation, all specimens were stored in distilled water at 37ºC for 24 hours, and thermal cycled (1000 cycles, 5 to 55°C, dwell time of 30 seconds). After the thermal cycles, the specimens were stored in 37ºC distilled water for an additional 24 hours (n=10) or 6 months (n=10) before being subject to a shear load using a mechanical testing machine (Material Test System 810). Mode of failure was observed by means of stereomicroscopic, and classified as either adhesive, cohesive or a combination of both. Data were analyzed using parametric tests (α=.05).
48

Influência do sistema de cimentação adesiva e da fonte de luz fotoativadora na resistência à extrusão de pinos de fibra de vidro /

Lima, Luiz Rafael Calixto. January 2009 (has links)
Resumo: A retenção de pinos pré-fabricados de fibra de vidro, utilizados na restauração de dentes com tratamento endodôntico, é baseada na sua união às superfícies das paredes do canal radicular, por meio dos agentes de fixação resinosos. O tipo de pino utilizado, assim como a fonte de luz fotoativadora do cimento, também pode influenciar nessa retenção, principalmente nas regiões mais críticas do canal, como o terço apical, onde há uma grande dificuldade de acesso dessa luz ativadora. Assim, o propósito deste trabalho foi avaliar comparativamente a influência de diferentes sistemas de cimentação (químico convencional; dual convencional, químico com adesivo auto-condicionante, dual com adesivo auto-condicionante e cimento dual auto-adesivo), na resistência à extrusão (push-out) de pinos de fibra de vidro, nos diferentes terços do canal (cervical, médio, aplical). Foi avaliada também a influência do tipo de fonte de luz fotoativadora do cimento: luz halógena (Optilux 501) e LED (Ultraled). O tipo de falha foi avaliado através de microscopia. Foram utilizadas 240 unidades experimentais, em forma de discos, com aproximadamente 1 mm de espessura, retirados de 80 raízes bovinas, restauradas com retentores intraradiculares. Foi utilizada uma máquina de ensaios universais, MTS 810 Material Test System, à velocidade de 0,5 mm/min-1, com célula de carga de 50 Kg, para avaliação da resistência push-out nos diferentes terços de cada corpo-de-prova. Os valores de resistência em kgf, foram convertidos para MPa e analisados por meio de Análise de Variância e teste de Tukey, com nível de significância de 5%. Os resultados mostraram baixos valores de retenção para os grupos com os cimentos autoadesivos,independente da fonte de luz utilizada. Os cimentos de condicionamento ácido total e os de adesivos auto-condicionantes parecem ser opções viáveis no processo... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The retention of prefabricated glass fiber posts, used for the restoration of endodontically-treated teeth, is based on adhesive systems and resin luting cements. The type of posts used, as well as the type of activation of the cement can also influence this retention, mainly in more critical areas of the radicular dentin, such as the apical root segments, where there is a great difficult access of the light curing units. Thus, the purpose of this study was to evaluate the influence of different resin cements (Chemical-cure total-etch; dual-cure total-etch; chemicalcure and self-etch bonding system, dual-cured and self-etch bonding system; and dual-cure self-adhesive cement) on the bond strength (push-out) of glass fiber posts on the different thirds of the root (cervical, middle and apical). The influence of the light curing unit was evaluated by halogen LCU (Optilux 501) and by LED LCU (LEC II 470) use. The failure mode was evaluated by stereoscopic microscope. Disks of the samples (n=240) were used, with approximately 1 mm of thickness of 80 bovine roots restored with glass fiber posts. A universal testing machine (MTS 810 Material Test System) was used with a 1 mm diameter steel rod at cross-head speed of 0,5 mm/min until post extrusion, with load cell of 50 kg, for evaluation of the push-out strength in different thirds of each sample. The pushout strength values in kgf were converted to MPa and analyzed through Analysis of Variance and Tukey's test, with significant level of 5%. The results of the present study showed that the self-adhesive cements group resulted in low retention values, in every light source utilized. The total-etch cements and the self-etch bonding systems seem to be a viable alternative in the glass fiber posts cementation process, with either halogen light or LEDs. / Orientador: Marcelo Ferrarezi de Andrade / Coorientador: Alessandra Nara de Souza Rastelli / Banca: José Roberto Cury Saad / Banca: Edson Alves de Campos / Mestre
49

Efeito do selamento dentinário imediato na resistência de união de restaurações cerâmicas / Effect of immediate dentin sealing on bond strength of ceramic restorations

Mariana de Andrade Macêdo 16 December 2009 (has links)
O objetivo deste trabalho foi avaliar o efeito do selamento dentinário imediato na cimentação definitiva de restaurações cerâmicas (Empress2Ivoclar Vivadent), levando em consideração a influência de diferentes métodos de remoção dos restos de cimento provisório da superfície dentinária previamente selada. Para isso foram utilizados 72 molares, hígidos, conseguidos no banco de dentes da Universidade do Estado do Rio de Janeiro. Os dentes foram divididos em nove grupos, os três primeiros serviram como grupo controle, onde não houve contaminação com nenhum cimento provisório, sendo eles: G1, onde o selamento e a cimentação definitiva foram feitas 15 dias após a confecção dos preparos cavitários; G2, onde o selamento dentinário foi feito imediatamente após o preparo e a cimentação definitiva após 15 dias; G3, onde o preparo, selamento e cimentação definitiva foram feitos no mesmo momento. Os próximos grupos foram os do selamento tardio, onde o sistema adesivo foi aplicado somente no momento da cimentação. Nestes grupos, após o preparo foram cimentadas restaurações provisórias com um cimento livre de eugenol (Temp BondNE) e após 15 dias as restaurações provisórias foram removidas e os restos de cimento limpos com diferentes métodos: G4: remoção com instrumento manual; G5: remoção com jato de bicarbonato; G6: remoção com pontas de ultra-som; após esta limpeza o sistema adesivo foi aplicado e as restaurações cerâmicas cimentadas. Por último foram os grupos do selamento dentinário imediato, onde o sistema adesivo foi aplicado imediatamente após a confecção dos preparos cavitários e em seguida foi feita a cimentação das restaurações provisórias. Após 15 dias as restaurações provisórias foram removidas, os restos de cimento foram limpos com os diferentes métodos: G7: remoção com instrumento manual; G8: remoção com jato de bicarbonato; G9: remoção com pontas de ultra-som. Após a limpeza as restaurações cerâmicas foram cimentadas. Para todos os grupos o sistema adesivo utilizado foi o Optibond FL Kerr e o cimento resinoso foi o Rely X ARC3M/ESPE. Vinte e quatro horas após as cimentações cerâmicas os corpos de prova foram submetidos ao ensaio mecânico de push out em uma máquina de ensaios universais EMIC DL. Os valores de resistência de união foram obtidos em KgF, convertidos em MPa e analisados estatisticamente. O teste de ANOVA mostrou que houve diferença estatisticamente significante entre os grupos (p&#8804;0,05) e em seguida o t-teste mostrou que a técnica do selamento imediato resultou nos melhores valores de resistência de união. Por último, o teste de comparações múltiplas Student-Newman-Keuls (Teste SNK) mostrou que o método de limpeza dos restos de cimento provisório da superfície dentinária apresenta influência na resistência de união das restaurações cerâmicas. Com base nos resultados pôde-se concluir que a técnica do selamento imediato promoveu maior resistência adesiva para as restaurações cerâmicas e quanto ao método de limpeza, o melhor resultado, independente da técnica adesiva utilizada, foi a remoção com as pontas de ultrasson. / The aim of this study was to evaluate the effect of immediate dentin sealing on bond strength of ceramic restorations, taking into account the influence of different techniques used to remove temporary cement remainings from dentin surfaces. Seventy two intacts and caries free human molars were taken from UERJ teeth bank in order to perform the necessary experiments. They were divided into nine groups. The first three groups served as control groups and there was no contamination with temporary cements: G1, the dentin sealing and ceramic cementation were made fifteen days after preparation; G2, the dentin was sealed immediately after preparation and after fifteen days the ceramic restorations were fixed; G3, wich the praparation, dentin sealing and ceramic cementation were made at the same time. The next three groups constituted the delayed dentin sealing group, where the dentin bonding agent were applied only in the moment of ceramic cementation. After preparation, provisional restorations were placed with a provisional cement without eugenol (Temp BondNE) and after fifteen days they were removed and dentin surfaces were cleaned by differents methods: G4: hand instrument; G5: sodium bicarbonate jet; G6: ultra-sonic scaler. The adhesive system was then applied and the ceramics were bonded. The three last groups constituted the immediate dentin sealing, where the dentin bonding agent was applied immediately after preparation, before provisional cementation. Following fifteen days, the provisional restorations were removed and the sealed dentin were cleaned by differents methods: G7: hand instrument; G8: sodium bicarbonate jet; G9: ultra-sonic scaler. After these procedures the ceramic restorations were bonded. The adhesive system used in all groups was Optibond Kerr and the resin cement was Rely X ARC3M/ESPE. Following twenty four hours all specimens were submitted to the push-out test in a universal testing machine EMIC DL. The push out bond strength was obtained in KgF and were then converted into MPa. The results were analysed: one-way ANOVA revealed significant differences between groups (p&#8804;0,05), t-test showed that immediate dentin sealing provided the highest values of bond strength. At least, the Multiple comparisions SNK Test detected that the differents techniques used to remove temporary cement remainings from dentin surfaces had an influence on the ceramic bond strength, and even when immediate dentin sealing or delayed dentin sealing was used, the ultra-sonic scaler showed the better results.
50

Nanotubos de nitreto de boro como carga para resinas adesivas

Degrazia, Felipe Weidenbach January 2017 (has links)
O objetivo do presente estudo foi desenvolver e avaliar a incorporação de nanotubos de Nitreto de Boro (BNNT) como carga em uma resina adesiva. Foi formulada uma resina adesiva utilizando-se os seguintes reagentes: 2- hidróxietil metacrilato (HEMA), Bisfenol A glicol dimetacrilato (BisGMA), canforoquinona (CQ) e Etil 4-dimetilaminobenzoato (EDAB). Os BNNTs foram caracterizados por Microscopia Eletrônica de Varredura (MEV) e Microscopia Eletrônica de Transmissão (MET). O adesivo experimental com diferentes concentrações de BNNT (0, 0,05, 0,075, 0,1 e 0,15%) foi caracterizado quanto ao ângulo de contato e energia livre de superfície (ELS), dureza e amolecimento em solvente (solução de etanol) em microdurômetro, deposição mineral até 14 dias e grau de conversão por espectroscopia Raman e resistência coesiva. O adesivo experimental com diferentes concentrações de BNNT após imersão por 3 h em 65% HNO3 e 48 h em H2O2 foi caracterizado por grau de conversão e cinética de polimerização por Espectroscopia de infravermelho por transformada de Fourier (FTIR), ângulo de contato em dentina por tensiômetro, citotoxicidade por sulforodamina B (SRB) e resistência de união imediata e longitudinal Os resultados da análise de microscopia eletrônica de varredura e de transmissão demonstraram nanotubos de nitreto de boro com diâmetros de 5 a 10 nanometros com término fechado. Nenhuma modificação no grau de conversão ocorreu após a incorporação de BNNTs até 0,15%. Os ângulos de contato de água e α-bromonaftaleno aumentaram (p < 0,05) e consequentemente a ELS diminuiu após a incorporação de BNNTs ao adesivo. Houve aumento da microdureza e da resistência ao amolecimento em solvente após incorporação de 0,075, 0,1 e 0,15% de BNNTs. Não houve diferença significativa na resistência coesiva entre os diferentes grupos. Foi encontrada deposição mineral nos espécimes com BNNT após sete dias de imersão em SBF (fluido corporal simulado). Após o tratamento dos BNNTs com HNO3 e H2O2 e incorporação ao adesivo, houve aumento do grau de conversão e da taxa de polimerização máxima após incorporação de 0,075 e 0,1% de BNNT. O ângulo de contato à dentina aumentou após a incorporação de 0,15% BNNT. Não houve diferença significativa na resistência de união entre os grupos após 24 h (p >0,05). Após 6 meses a resistência de união diminuiu significativamente para o grupo 0% e 0,15% BNNT. Entretanto, os grupos que tiveram incorporação de BNNT obtiveram maiores valores que 0% (p <0,05). Não houve diferença no crescimento celular (p >0,05) entre os grupos em comparação ao grupo controle positivo (100% de crescimento). A incorporação de BNNT até 0,15% melhorou as propriedades físico-químicas do adesivo dentário, promoveu deposição mineral e aumentou a estabilidade longitudinal sem apresentar citotoxicidade a fibroblastos, fornecendo benefícios consideráveis frente aos materiais disponíveis no mercado. / The aim of this study was to develop and evaluate the incorporation of boron nitride nanotubes (BNNTs) into an adhesive resin. An adhesive resin was developed using the following reagents: 2-hydroxyethyl methacrylate (HEMA), bisphenol-A glycidyl dimethacrylate (BisGMA), camphorquinone (CQ) e ethyl 4- dimethylaminobenzoate (EDAB). BNNTs were characterized by Scanning Electron Microscopy (SEM) and Transmission Electron Microscopy (TEM). The experimental adhesive with different concentrations of BNNT (0, 0.05, 0.075, 0.1 e 0.15%) was characterized by contact angle and surface free energy (SFE), hardness and softening in solvent (ethanol solution) by microdurometer, mineral deposition up to 14 days and degree of conversion by Raman spectroscopy and ultimate tensile strength test. The experimental adhesive with different concentrations of BNNT after immersion for 3 h in 65% HNO3 and 48 h in H2O2 was characterized by degree of conversion and polymerization kinetics by Fourier Transform Infrared Spectroscopy (FTIR), contact angle in dentin by tensiometer, sulforhodamine B (SRB) cytotoxicity and immediate and longitudinal bond strength. The results of scanning and transmission electron microscopy showed boron nitride nanotubes with diameters of 5 to 10 nanometers with closed end tips No change in degree of conversion occurred after the incorporation of BNNTs up to 0.15%. The contact angles of water and α-bromonaphthalene increased (p <0.05) and consequently SFE decreased after the incorporation of BNNTs to adhesive. After incorporation of 0.075, 0.1 and 0.15% BNNTs an increase was shown in microhardness and resistance to softening in solvent. No significant difference in ultimate tensile strength was found among groups. Mineral deposition was found on BNNT specimens after seven days of immersion in SBF (simulated body fluid). After BNNTs´ treatment with HNO3 and H2O2 and incorporation into the adhesive, there was an increase in the degree of conversion and the maximum polymerization rate after incorporation of 0.075 and 0.1% of BNNT. Contact angle in dentin increased after incorporation of 0.15% BNNT. There was no significant difference in microtensile bond strength among groups after 24 h (p> 0.05). After 6 months the bond strength decreased significantly for 0% group and 0.15% BNNT. However, the groups that had BNNT incorporation obtained higher values than 0% (p <0.05). There was no difference in cell growth (p> 0.05) among groups compared to the positive control group (100% growth). The incorporation of BNNT up to 0.15% improved the physicochemical properties of dental adhesive, promoted mineral deposition and increased longitudinal stability with no cytotoxicity to fibroblasts, providing considerable benefits against dental materials available in the market.

Page generated in 0.0652 seconds