• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 604
  • 39
  • 39
  • 39
  • 39
  • 23
  • 11
  • 11
  • 10
  • 10
  • 5
  • 5
  • 2
  • 1
  • Tagged with
  • 625
  • 625
  • 321
  • 252
  • 178
  • 146
  • 142
  • 142
  • 115
  • 110
  • 74
  • 73
  • 73
  • 61
  • 57
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Avaliação imediata e após 6 meses da resistência de união a dentina de restaurações de resina composta classe I in vivo e in vitro /

Rêgo, Heleine Maria Chagas. January 2015 (has links)
Orientador: César Rogério Pucci / Co-orientador: Eduardo Bresciani / Banca: Taciana Marco Ferraz Caneppele / Banca: Daphne Barcelos / Banca: Dulce Maria Santos Simões / Banca: André Figueiredo Reis / Resumo: Este estudo avaliou a resistência de união a dentina de restaurações de resina composta de forma imediata (24 horas) e em longo prazo (6 meses), submetidos a diferentes protocolos de envelhecimento. Cem dentes posteriores humanos foram divididos em cinco grupos (n = 20) de acordo protocolo de envelhecimento que receberam e posteriormente subdivididos em dois subgrupos (n = 10) de acordo com o tempo de armazenamento, totalizando dez subgrupos: In vivo (permaneceu em atividade bucal por 24 horas ou 6 meses); Estufa (armazenado em água destilada em estufa a 37 °C por 24 horas ou 6 meses); Ciclagem (submetidos a 27/666 ou 5000/120000 ciclos termomecânicos); Estufa com Pressão Pulpar Simulada (PPS) (restauração realizada sob PPS e em seguida armazenado em água destilada em estufa a 37 °C por 24 horas ou 6 meses); Ciclagem com PPS (restauração realizada sob PPS e em seguida submetidos a 27/666 -24 horas- ou 5000/120000 -6 meses- ciclos termomecânicos). Após a abertura da cavidade, a restauração foi realizada com a aplicação de ácido fosfórico a 37% (Vigodent), sistema adesivo Adper Single Bond 2 (3M ESPE) e resina composta Grandio (Voco), seguindo a orientação dos fabricantes. Após os diferentes tratamentos os espécimes foram seccionados obtendo-se palitos que foram submetidos ao teste de microtração. Os valores obtidos foram submetidos ao teste ANOVA dois fatores (protocolo de envelhecimento e tempo de armazenamento) e em seguida ao Teste de Tukey (5%). Os resultados para os testes de microtração foram (em MPa ±dp): Grupo estufa 24 h, 24,96±0,95A; Grupo ciclagem 24 horas, 23,96 ± 0,56AB; Grupo in vivo 24 horas, 23,21 ± 1,23AB; Grupo ciclagem com PPS 24 horas, 19,49 ± 1,51BC, Grupo ciclagem 6 meses, 18,16 ± 0,80CD; Grupo ciclagem com PPS 6 meses, 17,88 ± 1,25CD; Grupo estufa com PPS 24 horas, 17,65 ± 0,45CD; Grupo estufa 6 meses, 16,68 ± 1,30CD; Grupo estufa com PPS 6 meses, 14,33 ± 1,48D; Grupo in vivo 6 meses,.... / Abstract: This study evaluated the bond strength of composite resin restorations submitted to different storage aging protocols, immediately and long-term (6 months). One hundred human posterior teeth were divided into five groups (n = 20) according storage aging protocol: Group, Group in vivo, Group water, Group cycling, Group water with Simulated Pulpal Pressure (PPS) and Group cycling with Simulated Pulpal Pressure. As further subdivided into two subgroups (n = 10) according to the time of storage were performed: 24 hours (24 hours in vivo 24 hours in water, 27/666 thermal and mechanical cycles) 6 months (6 months in vivo, 6 months in water and 5000/120000 thermal and mechanical cycles). After the opening of the cavity, the restoration was carried out with the use of phosphoric acid 37% (Vigodent), Single Bond 2 adhesive system (3M ESPE) and composite resin Grandio (Voco), following the lead of the manufacturers. After being held aging protocols for the storage time subgroup belonging specimens were sectioned obtaining sticks were submitted to microtensile test. Data were submitted to ANOVA two factors (aging and storage time) and then Tukey test (5%). The results for the microtensile tests were (MPa) ± SD: Group water 24 hours, 24.96 ± 0.95A; Group cycling 24 hours, 23.96 ± 0.56AB; Group in vivo 24h, 23.21 ± 1.23AB; Group cycling with PPS 24 hours, 19.49 ± 1.51BC, group cycling six months, 18.16 ± 0.80CD; Group cycling with PPS 6 months, 17.88 ± 1.25CD; Group water with PPS 24 hours, 17.65 ± 0.45CD; Group water 6 months, 16.68 ± 1.30CD; Group water with PPS 6 months, 14.33 ± 1,48D; In vivo group 6 months, 14.16 ± 1,51D. It was concluded that the different aging protocols used as storage times influence the bond strength dentin-resin / Doutor
72

Preparo e caracterização de compósitos polímero/cerâmica com potencial aplicação como sensor multifuncional /

Macario, Leilane Roberta. January 2013 (has links)
Orientador: Elson Longo / Banca: Maria Aparecida Zaghete Bertochi / Banca: Máximo Siu Li / Banca: Gilberto de Campos Fuzari Junior / Banca: Renata Cristina de Lima / Resumo: Este trabalho teve como meta o preparo e o estudo de compósitos polímero/cerâmica com potencial para aplicação como sensor multifuncional, para ser utilizado, tanto para conversão de energia mecânica em energia elétrica bem como para emissão de luz. Para a preparação desse compósito, diferentes pós cerâmicos de estrutura perovskita puros e dopados, com a terra-rara európio (Eu), foram obtidos via Método dos Precursores Poliméricos. Estes pós foram preparados com o objetivo de estabelecer a otimização das propriedades piezoelétricas e luminescentes. Por outro lado os pós misturados ao polímero poli fluoreto de vinilideno (PVDF), formaram os filmes compósitos. Os resultados obtidos neste trabalho foram divididos em 3 tópicos. No primeiro tópico os materiais cerâmicos de BaZrxTi1-xO3 com (x = 0; 0,05; 0,08; 0,1; 0,25; 0,50; 0,75 e 1) foram obtidos e caracterizados. No segundo tópico foram sintetizadas e analisadas as amostras cerâmicas dopadas com íons Eu; Ba1-yEuyZr0,08Ti0,92O3, Ba1-yEuyTiO3 e Ba1-yEuyZrO3 com (y = 0,005; 0,01; 0,02 e 0,04). No terceiro tópico as cerâmicas de melhores propriedades piezoelétricas formaram compósitos com o polímero PVDF em condições que foram otimizadas. Para a caracterização estrutural foram utilizadas as técnicas de Difratometria de Raios-X e a Espectroscopia Raman. A propriedade ótica foi analisada por Espectroscopia de Reflectância no Ultravioleta e Visível e Fotoluminescência. A morfologia das cerâmicas e a superfície e a distribuição da cerâmica no polímero foram observadas por Microscopia Eletrônica de Varredura de Emissão de Campo. A condutividade elétrica, o coeficiente piezelétrico longitudinal d33 e as curvas de histerese foram as ferramentas utilizadas para análise das propriedades elétricas. Todos os compósitos formados apresentaram as propriedades de piezoeletricidade e de fotoluminescência, portanto, possuem condições para serem aplicados como... / Abstract: This research aimed the preparation and study of polymer/ceramic composites with potential applications as multifunctional sensors, to be used for converting mechanical into electrical energy as well as for light emissions. Different perovskite ceramics powders (pure and doped with europium) were obtained by the Polymeric Precursor Method in order to establish the optimization of piezoelectric and luminescent properties. The composite films were formed by the junction of ceramic powders with poly vinylidene fluoride polymer. The results obtained in this study were divided into three topics. In the first topic ceramic materials BaZrxTi1-xO3 (x = 0, 0.05, 0.08, 0.1, 0.25, 0.50, 0.75 and 1) were obtained and characterized. In the second topic were collated and analyzed the ceramic samples doped with ions Eu3+: Ba1-yEuyZr0,08Ti0,92O3, Ba1-yEuyTiO3, and Ba1- yEuyZrO3 with (y = 0.005, 0.01, 0.02, and 0.04). In the third topic several variables were tested in order to optimize the composites formation using the best conditions. The composites that were obtained in the optimized conditions were analyzed. For structural characterization were used the X-Ray Diffraction and Raman Spectroscopy techniques. The optical property was analyzed by Reflectance Spectroscopy in the UV-Vis range and Photoluminescence measurements. The ceramic surface morphology and the ceramic distribution in the polymer were studied by Scanning Electron Microscopy Field Emission Gun. The electrical conductivity, the longitudinal piezoelectric coefficient d33, and hysteresis curves of these materials were the tools used to analyze their electrical properties. All composites showed the piezoelectricity and the photoluminescence properties and therefore are able to be applied as a multifunctional sensor. / Doutor
73

Estudo clínico prospectivo e randomizado de restaurações de classe II utilizando resinas de baixa contração de polimerização /

Frascino, Sandra Meira Borghi. January 2017 (has links)
Orientador: André Luiz Fraga Briso / Coorientadora: Ticiane Cestari Fagundes / Banca: Renato Herman Sundfeld / Banca: Carlos Eduardo Francci / Resumo: Objetivo: O objetivo deste estudo clínico, prospectivo, randomizado, duplo-cego, foi avaliar a sensibilidade pós-operatória, o desempenho clínico e os contatos interproximais após a utilização de três diferentes estratégias restauradoras. Materiais e métodos: 159 restaurações de Classe II foram realizadas em pré-molares e molares de 53 pacientes, com idade média de 48 anos (21-78). Cada paciente recebeu ao acaso 3 restaurações, de acordo com os seguintes sistemas restauradores: PA- utilizou resina convencional, inserida pela técnica incremental (Peak Universal + Amelogen Plus, Ultradent); ABF- utilizou uma resina de baixa contração, inserida em incrementos únicos de até 4 mm, seguida da cobertura com resina nanoparticulada (Adper Single Bond+ Filtek Bulk Fill Flow+ Z350XT Body); XST- utilizou uma resina de baixa contração, inserida em incremento único de até 4 mm, seguida da cobertura com resina nanohíbrida, (XP Bond+ SDR+ TPH3). A sensibilidade pós-operatória foi avaliada utilizando uma escala analógica visual modificada (1-6), em 24 h, 7, 30, 90 dias e 6 meses após as restaurações. Dois examinadores avaliaram o desempenho clínico das restaurações utilizando critérios USPHS modificados em Baseline, 6 meses e 1 ano após as restaurações. Os contatos interproximais foram avaliados com uma escala de classificação numérica (0-4) nos mesmos períodos que os critérios USPHS. Resultados: A maior média de sensibilidade foi relatada em 24h, sendo constatada redução significativa da sen... (Resumo completo, clicar acesso eletrônico abaixo) / Objective: The aim of this prospective, randomized, double-blind clinical study was to evaluate postoperative sensitivity, clinical performance and interproximal contacts after using three different restorative strategies. Materials and methods: 159 Class II restorations were performed on premolars and molars of 53 patients, with a mean age of 48 years (21-78). Each patient randomly received 3 restorations, according to the following restorative systems: PAused conventional resin, inserted by the incremental technique (Peak Universal + Amelogen Plus, Ultradent); ABF- used a low- shrinkage resin, inserted in single increments of up to 4 mm, followed by coating with nanoparticulate resin (Adper Single Bond + Filtek Bulk Fill Flow + Z350XT Body); XST- used a low contraction resin, inserted in a single increment up to 4 mm, followed by coating with nanohybrid resin, (XP Bond + SDR + TPH3). Postoperative sensitivity was assessed using a modified visual analogue scale (1-6), at 24 h, 7, 30, 90 days and 6 months after the restorations. Two examiners evaluated the clinical performance of the restorations using modified USPHS criteria at Baseline, 6 months and 1 year after the restorations. The interproximal contacts were evaluated with a numerical classification scale (0-4) in the same periods as the USPHS criteria. Results: The highest mean sensitivity was reported in 24h, with a significant reduction in spontaneous sensitivity for all the groups after 30 days. Regarding the sensitivity to cold, the ABF group remained without reducing the sensitivity over time. There was no statistical difference when the heat sensitivity was evaluated. Regarding clinical performance, color, marginal discoloration and superficial spotting showed differences between the groups. Only the XST group did not show superficial spotting after 1 year. No differences... / Mestre
74

Compósito de borracha natural com incorporação de bagaço da cana-de-açúcar /

Paiva, Fábio Friol Guedes de. January 2018 (has links)
Orientador: Aldo Eloizo Job / Banca: Lucas Fugikawa Santos / Banca: Flávio Camargo Cabrera / Resumo: Poluição atmosférica e ambiental, oriunda da queima de resíduos industriais, é motivo de investigação científica para sua redução, onde o desenvolvimento de materiais orgânicos, sem emissão de CO2 e de baixo custo, objetivam a redução da queima dos resíduos e servem de alternativa como substituinte de produtos derivados da rota petroquímica. Neste contexto, a presente pesquisa propôs o desenvolvimento de um compósito utilizando a borracha natural (BN), como matriz polimérica, e fibras de resíduo do bagaço da cana-de-açúcar (RCA) para a produção de um eco-compósito. Os compostos foram denominados BN/RCA, sem tratamento, e BN/RCAT, para os compósitos tratados. Para obter o compósito, o bagaço de cana-de-açúcar foi micronizado, peneirado em mesh 170, tratado com hidróxido de sódio a 10%m e incorporado na borracha proporções de 10 a 40 phr (per hundred rubber). Para avaliar a composição química e a superfície do resíduo, primeiro as amostras de RCA e RCAT foram caracterizadas estruturalmente e morfologicamente pelas técnicas de fluorescência de raios X (FRX), difração de raios X (DRX) e microscopia eletrônica de varredura (MEV). Os compósitos também foram caracterizados pelas técnicas de ensaio mecânico de tensão vs. deformação, dureza Shore A, resistência à abrasão, ensaio de ligações cruzadas e análises térmicas. O tratamento alcalino permitiu incorporar maiores quantidades de resíduo sem perda significativa de propriedades mecânicas. O uso do resíduo tratado aumentou a resistê... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Atmospheric pollution, from the burning of industrial waste, is a reason for scientific research to reduce it, improving a quality of life around the world. Organic materials, with no emission of CO2 and low cost, are alternatives for substitution of products derived from the petrochemical route. In this context, this research proposed the development of a composite, using a natural rubber (NR), as polymer matrix, and sugarcane bagasse (SCB) residue fibers for an eco-composite production. The compounds denominated NR/SCB, without treatment, and NR/SCBT, for the treated composites. To obtain the composite, the micronized sugarcane bagasse, sifted in mesh 170, treated with 10% sodium hydroxide and incorporated in the rubber proportions of 10 to 40 phr (per hundred rubbers). To evaluate the chemical composition and the surface of the residue, first as samples of SCB and SCBT were characterized structurally and morphologically by the techniques of x-ray fluorescence (XRF), X-ray diffraction (XRD) and scanning electron microscopy (SEM). The composites were also characterized by mechanical stress vs. strain, Shore A hardness, abrasion resistance, crosslink density and thermal analysis. The alkaline treatment allowed to incorporate larger volumes of waste without significant loss of mechanical properties. The use of the treated residue increased the abrasion resistance by 28%, maintained the flexibility of the rubber composites and increased the deformation at rupture by 565% (NR) t... (Complete abstract click electronic access below) / Mestre
75

Resistência à fadiga e modo de fratura de pilares personalizados híbridos de metal e resina composta restaurados adesivamente em implantes na região de pré-molares

Boff, Luís Leonildo 25 October 2012 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2011 / Made available in DSpace on 2012-10-25T19:17:10Z (GMT). No. of bitstreams: 1 297508.pdf: 4775502 bytes, checksum: d7a7ab5600452272468784c5ecf9dffd (MD5) / Este trabalho compreende dois estudos com o objetivo de analisar o processo de corrosão de parafusos de retenção protética, através de microscopia eletrônica de varredura, espectroscopia de energia dispersiva, inspeção visual e perda de massa. No primeiro estudo, 23 parafusos usados foram investigados e comparados com um grupo controle de 10 parafusos novos. No segundo estudo, 40 parafusos de 4 fabricantes diferentes foram avaliados através de investigação in vivo e in vitro. Como conclusão, o processo oxidativo ocorre em parafusos de retenção protética e pode progredir para lesões corrosivas, especialmente em áreas com defeitos e retenção de detritos e contaminantes. Durante os primeiros 90 dias de uso intra-oral ou testes laboratoriais de imersão, os parafusos permanecem estáveis em relação ao seu aspecto visual, com insignificante perda de massa e um leve processo oxidativo.
76

Influência do tipo de tratamento da superfície de pinos de fibra de vidro na resistência de união à resina composta

Andretti, Fabio Luiz 25 October 2012 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2011 / Made available in DSpace on 2012-10-25T20:38:06Z (GMT). No. of bitstreams: 1 292660.pdf: 1105346 bytes, checksum: 6e67dd345d3a5f911bb733a71cd71a49 (MD5) / Os pinos de fibra de vidro são indicados para promover retenção adicional a núcleos de preenchimento ou a restaurações diretas. O objetivo deste estudo, in vitro, foi determinar a influência do tratamento da superfície na resistência de união de pinos de fibra a uma resina composta sob ensaio de push-out e observar o tipo de fratura sob microscopia eletrônica de varredura. Os grupos foram formados de acordo com o tratamento da superfície dos pinos: Grupo 1: silano (G1), Grupo 2: peróxido de hidrogênio 24% por 10 min e silano (G2), Grupo 3: jateamento com óxido de alumínio 50µm e silano (G3) e Grupo 4: jateamento com óxido de alumínio, peróxido de hidrogênio 24% e silano (G4) (n=20). Os dados foram submetidos ao teste de Shapiro-Wilk para verificar se os grupos apresentavam distribuição normal e teste de Kruskal-Wallis (p<0,05). Os resultados demonstraram que não houve diferença estatística significativa na interação entre os quatro grupos (G1: 11,08±10,16 MPa; G2: 16,24±8,49 MPa; G3: 12,81±9,89 MPa e G4: 11,14±8,58 MPa) (p=0,252). O tipo de fratura predominante foi misto (Tipo IV) e apenas duas fraturas adesivas (Tipo I) foram observadas (uma no Grupo G2 e outra no Grupo G3). O tratamento da superfície com peróxido de hidrogênio não alterou significativamente a resistência de união ao cisalhamento (push-out) do pino de fibra testado à resina composta.
77

Uso de pena de galinha na produção de painéis para construção civil /

Minutti, Fernanda Aparecida Alonge. January 2018 (has links)
Orientador: Obede Borges Faria / Coorientadora: Paula Valéria Coiado Chamma / Banca: João Roberto Gomes de Faria / Banca: Cristiane Inacio de Campos / Resumo: O presente trabalho apresenta uma alternativa para a minimização do descarte atual, crescente e inadequado do resíduo agronômico pena de galinha (Chicken Feather). Assim, foram estabelecidos parâmetros para gerar um novo produto, painéis de compósitos, com adição de resina ureia-formaldeído, visando verificar as propriedades e possibilidades de aplicação deste produto na construção civil. Ao longo do levantamento bibliográfico, notou-se que a pena de galinha é um tema ainda pouco explorado em pesquisas, traduzindo-se em uma lacuna a ser preenchida. Foi escolhida a resina ureia-formaldeído por ser um componente chave muito utilizado na indústria de chapas particuladas de madeira, o que facilitaria na avaliação comparativa de desempenho do novo compósito. Durante a realização da etapa experimental, constatando-se uma grande dificuldade na trituração das penas, optouse por usá-las inteiras. Ao final desta etapa, a qualidade física das chapas foi insuficiente para a produção dos corpos de prova necessários à realização dos ensaios de caracterização física e mecânica, sendo direcionado aos ensaios de desempenho térmico, para aplicação deste compósito como isolante térmico em edificações. Com a realização destes ensaios, constatou-se o potencial de adequação do material para esta aplicação. Comparados com materiais para isolamento térmico existentes no mercado, os painéis com pena de galinha apresentaram desempenho compatível, bloqueando cerca de 20ºC de temperatura entre uma face ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The present work presents an alternative for the minimization of current, increasing and inadequate disposal of agronomic chicken feather residue. Thus, parameters were established to generate a new product, composite panels, with addition of ureaformaldehyde resin, in order to verify the properties and possibilities of application of this product in civil construction. Throughout the bibliographical survey, it was noticed that the feather of chicken is a subject still little explored in researches, translating into a lacuna to be filled. The urea-formaldehyde resin was chosen as a key component widely used in the wood particleboard industry, which would facilitate the comparative evaluation of the new composite performance. During the realization of the experimental stage, it was verified a great difficulty in the crushing of the feathers, it was chosen to use them whole. At the end of this stage, the physical quality of the panels was insufficient for the production of the test specimens necessary for the physical and mechanical characterization tests, being directed to the thermal performance tests, for the application of this composite as thermal insulation in buildings. With the accomplishment of these tests, it was verified the potential of suitability of the material for this application. Compared with existing insulation materials on the market, the panels with chicken feather showed compatible performance, blocking about 20ºC of temperature between one face and anoth... (Complete abstract click electronic access below) / Mestre
78

Avaliação do desempenho de LEDs na ativação de um compósito odontológico através de ensaios de sorção, solubilidade, nanodureza e módulo de elasticidade

Juchem, Cristiane de Oliveira January 2005 (has links)
O objetivo deste estudo foi avaliar o desempenho de quatro aparelhos fotopolimerizadores comerciais que utilizam LED como fonte de luz: Elipar Free Light 2 (E), Radii (R), L.E.Demetron I (D) e Single V (S) na polimerização do compósito Z250, na cor A3, por 20s, através dos ensaios de sorção, solubilidade, nanodureza e módulo de elasticidade. Um fotopolimerizador convencional de lâmpada halógena XL2500 (XL) foi utilizado como parâmetro de comparação. Para o ensaio de sorção e solubilidade foram confeccionados 5 corpos de prova com 15mm de diâmetro e 1mm de espessura para cada aparelho fotopolimerizador. Os ensaios foram realizados segundo a especificação da ISO 4049:2000 e os resultados mostraram que todos os grupos atenderam às exigências da norma que permite, no máximo, 40g/mm2 de sorção e 7,5g/mm2 de solubilidade. Para o ensaio de nanodureza e módulo de elasticidade foram confeccionados 5 corpos de prova cilíndricos com 6mm de diâmetro e 4mm de altura, para cada aparelho fotopolimerizador. A medição foi feita, em profundidade (1mm, 2mm e 3mm), no interior do corpo de prova, 24 h após a confecção dos mesmos. Os valores de nanodureza foram obtidos a partir da média de quatro endentações, realizadas em cada uma das três profundidades, de cada corpo de prova, com o equipamento Fischerscope HV, utilizando penetrador Berkovich com carga de 250mN. Os resultados obtidos foram submetidos à análise de variância e ao teste de Tukey para comparação entre os aparelhos, em cada profundidade (α=0,05) e comparação individual de cada aparelho nas diferentes profundidades (α=0,05). Na profundidade de 1mm todos os grupos apresentaram valores de nanodureza estatisticamente superiores à profundidade de 3mm. Para a profundidade de 1mm não houve diferença estatisticamente significativa entre os aparelhos. Para a profundidade de 2mm os aparelhos LED R, D e S foram superiores ao XL, e E não apresentou diferença estatisticamente significativa de D, S e XL. Para a profundidade de 3mm, não foi observada diferença estatisticamente significativa entre os LEDs, sendo R estatisticamente superior ao XL. Os valores do módulo de elasticidade não mostraram diferença entre os grupos na profundidade de 1mm e para as profundidades de 2 e 3mm, o XL apresentou valor estatisticamente inferior aos LEDs que não mostraram diferença entre si. Os resultados permitiram concluir que todos os aparelhos LED analisados mostraram um desempenho no mínimo semelhante, senão melhor do que a lâmpada halógena, considerando as propriedades de sorção, solubilidade, nanodureza e módulo de elasticidade desenvolvidas por eles no compósito Z250.
79

Avaliação da transmitância direta de resinas compostas por meio de espectrofotometria de UV-visível

Masotti, Alexandre Severo January 2005 (has links)
Este estudo avaliou as porcentagens de Transmitância direta (Td) das resinas compostas microhíbridas Charisma F, Solitaire II (Heraeus Kulzer ), Intens e Tetric Ceram (Ivoclar Vivadent) e nanoparticuladas Esthet-X (Dentsply De trey) e Filtek Supreme (3M Espe) nas cores Vita A3 (Dentina) e translúcido (Esmalte), ou seus correspondentes. Foram confeccionados três corpos-de-prova para cada material e cor, de formato quadrangular com 12x12 mm de lado e espessura de 1 mm. Após fotoativação, foram realizadas três leituras por corpo-de-prova em espectrofotômetro de UV-visível HP 8453 (Hewlett-Packard), com temperatura e umidade controladas (22±2°C/50±5%). Os ângulos de incidência e leitura em 0° / 0° foram utilizados para os comprimentos de onda de 400 a 700 nm. Os espectros obtidos foram analisados quanto ao percentual médio de Td para todo o espectro, em intervalos de 20 nm, e nos comprimentos de onda de 400, 560 e 700 nm. Através de ANOVA e teste de Tukey (p=0,01) encontrou-se que a resina composta Charisma obteve as maiores porcentagens de Td em todos os espectros, exceto para a cor Esmalte em 700 nm, que ficou abaixo da resina composta Esthet-X cor Esmalte. O teste t-Student demonstrou serem significativamente maiores os percentuais de Td para os espectros das cores Translúcido, exceto para as resinas compostas Supreme, em que não diferiram, e Charisma, com porcentagens de Td significativamente maiores para a cor Dentina. Por meio de teste não paramétrico de Friedman verificou-se que todas as resinas compostas estudadas demonstraram aumento significativo de Td com o aumento do comprimento de onda, com exceção da resina composta Solitaire, cores Dentina e Esmalte, que não demonstrou diferenças significativas nos comprimentos de onda de 560 e 700 nm.
80

Influência da imersão em desinfetante a base de ácido peracético sobre as propriedades de um compósito odontológico de uso indireto

Fracaro, Gisele Baggio January 2005 (has links)
O objetivo deste trabalho foi avaliar a influência da imersão no desinfetante a base de ácido peracético 0,2% (STERILIFE, Lifemed Produtos Médicos Comércio Ltda, São Paulo, SP) sobre as propriedades de resistência flexural, sorção e solubilidade do compósito odontológico BelleGlass HP (Kerr, Orange, USA). Para cada ensaio foram confeccionados dez corpos de prova do compósito, utilizando-se as matrizes determinadas pela especificação no 4049 da International Organization for Standardization (ISO), sendo cinco submetidos a três imersões no desinfetante durante 10 minutos, intercaladas por 10 minutos em água destilada estéril e os outros cinco serviram como grupo controle. Para o ensaio de resistência flexural, após os corpos de prova ficarem imersos em água a 37° C, por 24 horas, foram levados à Máquina de Ensaio Universal DL 2000 (EMIC, São José dos Pinhais, Paraná, Brasil). A norma ISO n0 4049 exige uma resistência flexural mínima de 100 MPa. Para os ensaios de sorção e solubilidade os corpos de prova foram submetidos a ciclos a 37 C em um dessecador por 22 horas e, 2 horas em um segundo dessecador, a 23C, até a obtenção de uma massa constante (m1). Após 7 dias em banho de água a 37 C, procedeu-se à avaliação da massa do corpo de prova hidratado (m2). Posteriormente as amostras retornaram para o primeiro dessecador e todo o ciclo foi repetido até encontrar-se a terceira massa (m3) recondicionada. A norma ISO n0 4049 exige valores menores ou iguais a 40 g/mm3 e 7,5g/mm3 para a aprovação, em relação à sorção e solubilidade. Os resultados deste trabalho mostraram que as propriedades de resistência flexural, sorção e solubilidade do compósito BelleGlass HP de todos os corpos de prova dos grupos experimental e controle atenderam às exigências da especificação. Portanto pode se prever que o procedimento da imersão neste desinfetante não trará prejuízo às restaurações indiretas do compósito considerando as propriedades avaliadas.

Page generated in 0.0741 seconds