Efecto de la intensidad de la luz de las lámparas halógenas en el sellado marginal de restauraciones de clase I: Estudio in vitro

Camavilca Arias, Sharon Patty January 2010 (has links)
El trabajo de investigación in vitro sobre el “EFECTO DE LA INTENSIDAD DE LA LUZ DE LAS LÁMPARAS HALÓGENAS EN EL SELLADO MARGINAL DE RESTAURACIONES DE CLASE I”, se ejecutó en los consultorios odontológicos privados de la ciudad de Cerro de Pasco. Se efectuó dos visitas a los consultorios odontológicos: en la primera se explicó al odontólogo sobre el estudio y se solicitó una autorización para participar en él, en la segunda visita, se aplicó la encuesta, se inspeccionó físicamente la lámpara halógena, y se registró el rango de intensidad de la luz con un radiómetro de marca DEMETRON y finalmente se polimerizó la restauración de cada pieza dentaria respectiva. Para la medición de las intensidades de luz de las lámparas se realizó una prueba piloto midiendo la intensidad de la luz de las lámparas de fotocurado de la Facultad de Odontología de la Universidad Nacional Daniel Alcides Carrión, con el radiómetro marca “Demetron” para verificar su adecuado rendimiento. / --- The present work of investigation "EFFECT OF THE INTENSITY OF THE LIGHT OF THE HALOGENOUS LAMPS IN THE ONE SEALED MARGINAL SEALED OF RESTORATIONS OF CLASS I", was executed in the private dental offices of the city of Cerro of Pasco. For this work of investigatión two visits to the dental offices took place : first it was explained to the dentist about the study and an authorization was asked for to participating in it. In the second visit, the survey was,it was inspected the halogenous lamp physically, and registered the range of intensity of the light with a mark radiometro DEMETRON and finally you polymerization the restoration of each piece would jag respective . For the measurement of the intensities of light of the lamps it was carried out a test pilot measuring the intensity of the light of the lamps of fotocurado of the Faculty of Odontolgy of the Nacional University was made Daniel Alcides Carrión, with the radiometer "Demetron" marks to verify its appropriate yield.
12

Evaluación del grado de microfiltración de tres materiales utilizados como sellantes de fosas y fisuras profundas

Quispe Delgado, Ana María, Quispe Delgado, Ana María January 2017 (has links)
Determina cuál de los tres materiales presenta mayor grado de microfiltración: resina fluída autoadhesiva, ionómero para base cavitaria y giomero utilizados como selladores de fosas y fisuras. Utilzia 60 piezas entre premolares y molares permanentes sanas, extraídas por motivos ortodónticos y estos fueron divididos en cuatro grupos. Grupo control: Sellante, Grupo A: Resina fluída autoadhesiva, grupo B: Ionómero para base cavitaria y grupo C: Giomero. Los grupos se sometieron a un proceso de termociclado manual (300 ciclos en 5°C, 37°C y 55°C), se sumergieron en una solución de azul de metileno al 2% durante 24 horas. Luego se lavaron, se secaron, se seccionaron y finalmente fueron observados en un microscopio estereoscópico con aumento de 10X. El test no paramétrico de Kruskal Wallis y U Mann Whitney se utilizaron para ver si existía diferencia significativa y comparar la microfiltración entre los grupos. Se observa que existen diferencias entre los grupos de estudio con un nivel de significancia p= 0,000. No hubo diferencias significativas entre el giomero y el grupo control p=0,486. La resina fluída autoadhesiva presentó 6,7%de grado 0, 50% de grado 1 y 43,3% de grado 2 de microfiltración. El ionómero para base cavitaria, 0%de grado 0, 23,3% de grado 1 y 76,7% de grado 2 de microfiltración. El giomero, 36,7% de grado 0, 36,7% grado 1 y 26,7% de microfiltración. El grupo control, 50% de grado 0, 23,3% grado 1 y 26,7% de microfiltración. Concluye que el material que presentó mayor microfiltración fue el ionómero para base cavitaria con grado 2, luego la resina fluída autoadhesiva fue de grado 1 y el giomero fue de grado 0. / Tesis
13

Evaluación de grado de microfiltración in vitro de resinas microhíbridas y nanohíbridas en preparaciones cavitarias clase I en oclusal de premolares

Sarmiento Zúñiga, Giancarlo Jesús January 2019 (has links)
Determina el grado de microfiltración in vitro entre resinas microhíbridas y nanohíbridas en restauraciones Clase I en premolares. Se utilizó 32 piezas dentarias permanentes premolares sanas extraídas, se les realizo restauraciones Clase I de Black y fueron divididas en 2 grupos. Grupo A: Resina microhíbrida, grupo B: Resina Nanohíbrida. Los 2 grupos fueron sometidos a termociclado manual (300 ciclos a 5, 37 y 55°C), luego fueron sumergidos en solución al 2% de azul de metileno por 24 horas. Posteriormente se procedió a lavar, secar, seccionar y finalmente se observaron las muestras en un microscopio estereoscopio. Los datos obtenidos fueron procesados en el programa estadístico SPSS 20 IBM®. El tipo de análisis se realizó mediante la prueba estadística Chi cuadrado con prueba exacta de Fisher por ser variantes cualitativas, se usaron para observar si existía presencia de diferencia estadísticamente significativa y comparar entre ambos grupos el grado de microfiltración. Se encontró valores más altos de microfiltración en la resina microhíbrida sobre la nanohíbrida, pero sin diferencia estadísticamente significativa entre ambas resinas utilizadas (p= 0.089). Conclusión: El material menor presencia de grado de microfiltración fue la resina nanohíbrida sobre la microhíbrida, pero la diferencia no fue estadísticamente significativa. / Tesis
14

Efecto de la intensidad de la luz de las lámparas halógenas en el sellado marginal de restauraciones de clase I: estudio in vitro

Camavilca Arias, Sharon Patty January 2010 (has links)
No description available.
15

Fuerza de adhesión de una resina compuesta indirecta con diferentes tratamientos de superficie utilizando un cemento autoadhesivo sobre esmalte, estudio in vitro

Suaquita Lupaca, Vanessa Elizabeth January 2007 (has links)
El objetivo del presente estudio in vitro fue comparar la fuerza de adhesión de una resina compuesta indirecta con diferentes tratamientos de superficie y un cemento resinoso autoadhesivo a nivel de esmalte mediante el test de microtensión. Se utilizaron 18 dientes de bovino. Se construyeron bloques de resina con moldes de nylon mediante la técnica incremental oblicua. Se dividieron en seis grupos en función al tratamiento de superficie sobre el bloque de resina polimerizada: Grupo I (grabado ácido ortofosfórico 35%), Grupo II (grabado ácido ortofsfórico 35%+ Silano), Grupo III (microarenado con AL2O3), Grupo IV (microarenado con AL2O3 + Silano), Grupo V (ningún tratamiento de superficie), Grupo VI RelyX ARC (microarenado+sistema adhesivo convencional). Después de sumergir los dientes cementados por 24 horas en agua destilada, se efectuaron los cortes milimétricos y se obtuvieron por cada grupo de trabajo 30 especímenes, los cuales fueron sometidos a la prueba de microtensión a una velocidad de 0.5 mm/min hasta producirse la falla. Los resultados se analizaron con el Test (ANOVA) y el Post Test de Tukey con el fin de determinar las diferencias significativas entre los grupos experimentales (p≤ 0.05). El Grupo V (ningún tratamiento de superficie) y Grupo III (microarenado) presentaron la mayor fuerza de adhesión (40.04 MPa) y (38.92 MPa), respectivamente, mientras que el Grupo I (grabado con ácido ortofosfórico) obtuvo el valor más bajo (32.06 MPa). El tratamiento con ácido ortofosfórico disminuye significativamente la fuerza de adhesión. Bajo las condiciones del presente estudio, la resina compuesta presenta mayor fuerza de adhesión cuando no se realiza ningún tratamiento de superficie. / The aim of the present study in vitro, was to evaluate the bond strength of indirect composite with different surface treatment and a self-adhesive luting cement, at enamel level, by means of the microtensile test. Eighteen bovine teeth were used and cylindrical blocks composite were constructed with nylon mol with the oblique incremental technique. They were divided into six groups according to the surface treatment on the resin block: Group I(acid orthophosphoric etching 37%) Group II(acid orthophosphoric etching 37%+ Silane), Group III (sandblasting with AL2O3), Group IV (sandblasting with AL2O3+ Silane) Group V(without surface treatment), Group VI RelyX ARC (sandblasting with AL2O3 + resin adhesive). After storing the teeth cemented by 24 hours in distilled water, the samples were sectioned perpendicular to the bonded interface to obtain thick slabs from each bonded samples. Thirty beams per group (n=30) were submitted to tensile test universal testing machine at cross-head speed of 0.5mm/min, until failure. The values in Mpa were analyzed to ANOVA and Tukey Test, to determine the significant differences between the experimental groups (p is less than0.05). Significant differences were observed in bond strength values between the group without surface treatment and sandblasting 40.04 MPa and 38.92 MPa, and those treated with acid etched 32.06 MPa. The treatment with acid orthophosphoric, diminishes the bond strength significantly. Under the conditions of the present study, the composite indirect presents greater bond strength without surface treatment.
16

Accidente por extrusión de hipoclorito de sodio durante la irrigación endodóntica; reconstrucción directa con resina compuesta y pines intradentinarios en una pieza posterior con amplia destrucción coronal

Donayre Escriba, Julieta Emperatriz January 2014 (has links)
El documento digital no refiere asesor / Publicación a texto completo no autorizada por el autor / La desinfección del sistema de conductos radiculares se realiza mediante el uso de sustancias químicas auxiliares empleadas en la irrigación y medicación intraconducto. El irrigante de elección es el hipoclorito de sodio por poseer características importantes como capacidad de disolución de tejido pulpar y su poder bactericida. Sin embargo, del uso de esta solución irrigante pueden derivarse algunas complicaciones o accidentes, de las cuales la extrusión del hipoclorito de sodio fuera del foramen apical es la más severa. En ésta primera parte de la investigación, se describe el uso del hipoclorito de sodio como irrigante endodóntico, las características del accidente por extrusión del irrigante fuera del foramen, se realiza un reporte de caso clínico, se detalla el manejo del caso y se recomiendan medidas de prevención para evitar ésta complicación. El uso de pines intradentinarios se presenta como una opción en los casos en que la pérdida de estructura dental ponga en riesgo la retención de la restauración. Hasta la década de los noventa, la amalgama de plata era el material de restauración indicado para piezas posteriores; actualmente la gran demanda de resultados estéticos, así como la incorporación de nuevas técnicas de adhesión hace que la resina compuesta tenga gran aceptación. En el presente estudio se describe la técnica de inserción de los pines intradentinarios, ventajas y desventajas de su uso y se detalla el manejo de un caso clínico con resultados favorables en el tiempo. / Trabajo académico
17

Desempeño de la técnica adhesiva húmeda en etanol con un sistema adhesivo dental contemporáneo de grabado y lavado. Estudio ex-vivo

Caceres Monzon, Sheyla January 2018 (has links)
Evalúa el desempeño clínico de un sistema adhesivo contemporáneo (hidrófilo) aplicado con la técnica adhesiva húmeda en etanol, bajo un protocolo simplificado de deshidratación. Se recolecta la muestra a partir de 4 pacientes con tratamiento de ortodoncia, con 4 piezas dentarias por extraer en cada uno. Se realizan restauraciones de resina con dos técnicas adhesivas in vivo por paciente. Se emplea el sistema adhesivo Single Bond 2 (3M ESPE). Posteriormente las piezas tratadas son extraídas, y se distribuyen en los grupos: G1 (n=8): restauradas con la técnica húmeda en agua y G2 (n=8): restauradas con la técnica húmeda en etanol. Los dientes son almacenados 24hrs a 37°, para luego ser cortadas en los sentidos “x” e “y”, obteniendo cerillas que se someten a ensayos de tracción con el equipo Micro Tensile Tester de la casa dental BISCO. Tres cerillas por pieza dentaria son aisladas para realizar la evaluación de nanofiltración. Estas son sumergidas en nitrato de plata amoniacal; y luego, desgastadas con lijas al agua ASALITE 600, P1000A, 1200-A, P1500A, P2000A, P2500A, para su observación por microscopio óptico a 400X de aumento. Los datos de microtracción son evaluados con la prueba paramétrica T Student para muestras independientes; a los resultados de nanofiltración se aplica la prueba no paramétrica Chi cuadrado de homogeneidad. Se considera un nivel de significancia α˂0.05. / Tesis
18

Microdureza superficial en dientes artificiales de cuatro capas

Condori Larico, Lourdes Vanessa January 2017 (has links)
Determina la microdureza superficial de los dientes artificiales de cuatro capas divididos en tres grupos Duratone, Starplus y Chroma-4. Se analizan 45 muestras, 15 por cada grupo. Para evaluar la microdureza superficial Vickers, se elabora 45 bloques de 1.5 cm de alto y 2 cm de diámetro, en los cuales son expuestas las caras incisales de los dientes incisivos superiores, se realiza tres indentaciones por cada bloque, los cuales son llevadas a cabo con el microdurómetro marca LEITZ (WETZLAR). Los valores obtenidos de microdureza superficial Vickers fueron sometidos al análisis estadístico de ANOVA y prueba de comparación múltiple HSD DE TUKEY. Los resultados de microdureza superficial Vickers son Duratone (11,9 ± 0,6 kg/mm2), Starplus (14,6 ± 1,5 kg/mm2) y Chroma-4 (18,1 ± 1,4 kg/mm2), mostrando diferencia significativa con un valor de p<0,05. Por consiguiente, existen diferencias en los valores de microdureza superficial de los dientes artificiales de cuatro capas. / Tesis
19

Rugosidad superficial de resinas con nanopartículas sometida a tres sistemas de pulido

Bedón Rojas, Manuel Antonio January 2017 (has links)
Evalúa la rugosidad superficial de una resina con nanopartículas Tetric Ceram Bulk Fill® (Ivoclar Vivadent) sometida a tres sistemas de pulido en cuerpos de muestra prefabricados. Estudio experimental prospectivo longitudinal e in vitro, constituida por 30 cuerpos de muestra de resina Tetric® N-Ceram Bulk Fill. Se clasifican en 3 grupos de estudio: Jiffy®, Politip® + Astrobrush® y Sof-Lex®. Se evalúa la rugosidad superficial de cada cuerpo de muestra 4 veces con el RUGOSÍMETRO SJ-201P, Mitutoyo; obteniéndose una rugosidad media total y se realiza las mediciones en dos momentos (pre sistema de pulido y post sistema de pulido).Para el análisis de los datos, se utiliza un software estadístico SPSS v.22, evaluando la eficacia de pulido de los distintos sistemas, mediante técnicas de análisis descriptivos e inferenciales, con uso de T-Student para evaluación de diferencias de medias de las distintas muestras y la prueba de ANOVA con nivel de significancia p<0.05. / Tesis
20

Tratamiento restaurador con carillas directas de resina en dientes primarios

Magaño Machacca, Stefani Yuri January 2018 (has links)
El documento digital no refiere asesor / Propone tratamientos restaurativos con carillas de resina palfique Lx5 en dientes deciduos debido a su alta resistencia al desgaste dentario y su efecto de mimetizar el color dentario. Se reporta un caso de un paciente de 3 años 3 meses de edad, de sexo femenino; con diagnóstico a nivel estomatológico de pulpitis irreversible, conducta negativa; a quien se le realizó tratamiento odontológico integral, siendo uno de los tratamientos a nivel pulpar, pulpectomías, con restauraciones de carillas directas en el sector anterosuperior en Sala de Operaciones (SOP) del Instituto Nacional de Salud del Niño (INSN). Este reporte clínico muestra que las carillas directas colocados a nuestro paciente a base de resina palfique LX5, se mantienen en buen estado, con buena estabilidad en el color sin pigmentaciones, por lo cual no se presentó ninguna fractura debido a sus propiedades del material. / Trabajo académico