• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 261
  • 5
  • 5
  • 5
  • 5
  • 4
  • 3
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 265
  • 265
  • 265
  • 169
  • 160
  • 56
  • 49
  • 48
  • 43
  • 43
  • 41
  • 37
  • 31
  • 30
  • 29
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
121

Ensaios de arrancamento em solo grampeado executados em laboratório / Pullout tests in soil nailed wall built in laboratory

Fagner Alexandre Nunes de França 30 August 2007 (has links)
Solo grampeado é uma alternativa eficiente utilizada em obras de reforço de solos. É resultante da inclusão de reforços, denominados grampos, em um maciço em corte. A resistência ao cisalhamento da interface solo-grampo é um dos parâmetros mais importantes para fins de projeto. Este parâmetro é determinado a partir da experiência dos projetistas e se baseia principalmente no tipo de solo e em ensaios de campo (arrancamento, sondagens a percussão e pressiométricos). Neste contexto, a realização de ensaios de arrancamento in situ é extremamente importante para a quantificação deste parâmetro e, conseqüentemente, para a elaboração de projetos mais econômicos e seguros. A execução de ensaios de arrancamento em laboratório permite verificar condições muitas vezes não encontradas em campo. Este trabalho apresenta os resultados de ensaios de arrancamento de grampos realizados em laboratório. Também foi analisada a evolução da força nos grampos e dos deslocamentos do solo. Os grampos foram instalados em um protótipo de solo grampeado sobre o qual se aplicou uma sobrecarga de 50 kPa através de uma bolsa de ar comprimido. Os ensaios de arrancamento permitiram quantificar valores de resistência ao cisalhamento de interface da ordem de 145 kPa, mobilizados com pequenos deslocamentos dos grampos. O arrancamento de grampos instrumentados indicou que cerca de 90% do comprimento total dos grampos foi solicitado. Ao final dos ensaios de arrancamento, os grampos foram extraídos completamente do maciço de solo o que permitiu comprovar a sua integridade física. Os deslocamentos do solo foram máximos próximo ao topo do protótipo e na direção horizontal. Os resultados demonstram a viabilidade de estudar o comportamento do maciço reforçado a partir do comportamento do protótipo de solo grampeado construído em laboratório. / Soil nailing is an efficient soil reinforcement technique which uses inclusions, namely nails, in soil slopes. Unit skin friction is one of the most important parameters used in soil nailing design. The definition of this parameter is commonly based on local experience and correlations to some in situ tests. This work presents the results obtained from the pullout test carried out in a soil nailed wall prototype built in laboratory. Forces acting in nails were measured by strain gage instrumentation. Soil displacement was measured in short and long terms. The pullout tests were carried out after the application of a uniform surcharge given by a compressed air bag. The results showed that unit skin friction was about 145 kPa, mobilized with little nail displacements. About 90% of nail length were solicited during pullout tests, according to tests performed in strain gage instrumented nails. Nail extraction showed a high level of nail integrity. Soil displacements were higher close to the wall top, near the face. These results demonstrate the feasibility of using of laboratory prototype studies to investigate the geotechnical behavior of soil nailing structures.
122

Uso da tomografia por coerência óptica para detecção de falhas após ensaio de extrusão de pinos estéticos

COSTA, Daene Patrícia Tenório Salvador da 31 January 2013 (has links)
Submitted by Leonardo Freitas (leonardo.hfreitas@ufpe.br) on 2015-04-14T13:19:10Z No. of bitstreams: 2 Tese Daene da Costa.pdf: 1667535 bytes, checksum: fcc8264eb5582ea03bc9f87be2ed64a2 (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) / Made available in DSpace on 2015-04-14T13:19:10Z (GMT). No. of bitstreams: 2 Tese Daene da Costa.pdf: 1667535 bytes, checksum: fcc8264eb5582ea03bc9f87be2ed64a2 (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Previous issue date: 2013 / CAPES / Objetivo: Validar a Tomografia por Coerência Óptica (OCT) como método de obtenção de imagens capaz de detectar e diferenciar falhas após ensaio de extrusão de pinos estéticos cimentados com sistemas resinosos. Métodos: Foram obtidas imagens de 50 secções radiculares de pré-molares, que foram submetidos ao teste push-out após cimentação de pinos, em Microscópio Óptico (MO) com aumento de 50x e em OCT 2D e 3D para obtenção de cortes axiais e imagens en-face (SR-OCT:OCP930SR e Callisto SD-OCT/Thorlabs). Cada grupo de imagens foi analisado por 3 examinadores calibrados, para detectar a presença das seguintes falhas: Adesivas dentina/cimento (ADC) ou pino/cimento (ACP); Coesivas dentária (CD), de cimento (CC) ou de pino (CP); e Presença de bolhas (PB). Resultados: O escore de Kappa interexaminadores obtido pelo MO variou de 0,156 a 0,588 para as falhas adesivas, enquanto que pelo OCT variou de 0,733 a 1,000. As falhas coesivas apresentaram concordâncias similares nos dois métodos, que variaram de moderadas a excelentes. O OCT demonstrou ser mais sensível e específico na detecção das falhas ADC e CD, apresentando, ainda, mais especificidade nas falhas ACP, CC e PB. Significância: A origem das falhas na cimentação de pinos intrarradiculares pode influenciar na decisão terapêutica, mas é de difícil detecção pela subjetividade presente nos métodos avaliativos usuais. O OCT demonstrou ser um método eficaz e de baixo custo na detecção dessas falhas.
123

Propriedades mecânicas de cerâmicas de zircônia tetragonal policristalina contendo ítrio (Y-TZP) após aplicação de cerâmica / Mechanical properties of different stabilized tetragonal zirconia polycrystalline (Y-TZP) ceramics after veneering with ceramic

Marcelo Garbossa Francisco 16 April 2010 (has links)
Objetivo: Quantificar e comparar propriedades mecânicas, tais como resistência ao cisalhamento da interface de aderência zircônia/cerâmica, microdureza e resistência à flexão de corpos-de-prova confeccionados com diferentes cerâmicas de zircônia tetragonal policristalina contendo ítrio (Y-TZP) e cerâmica de revestimento aplicada. Método: Foram comparados, por meio de ensaios mecânicos, corpos-de-prova contendo zircônia nanopartículada ProtMat (Guaratinguetá, Brasil) e corpos-de-prova contendo zircônia microparticuladas ProtMat (Guaratinguetá, Brasil), Vita 2000 YZ CUBES (Zahnfabrik, Bad Säckingen Alemanha) e IPS e.maxZircad Ivoclar (Schaan/Liechtenstein). Foram confeccionados 84 corpos-de-prova (CP) em forma de blocos ou barras, estas últimas para o ensaio de flexão, sendo 21 de cada marca de zircônia. Todos os CPs foram sinterizados e uma zircônia de cada grupo foi caracterizada por difração de raios-X. Posteriormente foi realizada a aplicação de cerâmica CZR-Cerabien Zr (Noritake shinmachi, Nishi-ku, Nagoya, Japão) sobre os outros oitenta CPs, dos quais cinco CPs de cada grupo receberam a cerâmica em forma quadrangular e nos outros cinco CPs e em todas as barras foi aplicada à cerâmica de revestimento em toda a face. Foi realizado o ensaio de cisalhamento na interface de aderência zircônia/cerâmica dos CPs a partir de uma máquina de ensaio universal e avaliada a microdureza Vickers da interface dos CPs e o ensaio de flexão em quatro pontos das barras. Os CPs foram ainda avaliados sob microscópio óptico para verificação da interface zircônia/cerâmica e análise do tipo de fratura apresentada. Resultados: Os valores de dureza Vickers, tenacidade à fratura, resistência à flexão e resistência ao cisalhamento apresentados pelos corpos-de-prova preparados com partículas micrométricas foram de 1300HV, 9MPam-, 850MPa e 60kgf, respectivamente. Só houve diferença estatística nos ensaios de flexão e tenacidade à fratura, tendo a ProtMat nanoparticulada apresentado valores superiores quando comparada às demais. Conclusões: Os CPs apresentaram dureza, tenacidade à fratura, resistência à flexão e ao cisalhamento adequados para a utilização em odontologia, tendo os mesmos apresentado comportamentos semelhantes, apesar da resistência dos CPs em zircônia nanoparticulada ter sido superior à resistência da zircônia microparticulada. / Aim: The aim of this study was to quantify and compare mechanical and physical properties, such as Vickers hardness, fracture toughness, flexural strength and shear resistance of blanks of different Y-TZP zirconia ceramics used in the manufacture of dental prostheses after veneering with Noritake. Method: Commercially nano and microcrystalline zirconia blocks, pre-sintered bars and stabilized with yttria produced in Brazil (ProtMat) and imported (VITA 2000 YZ CUBES and IPS e.maxZircad Ivoclar). Eighty-four commercially samples were sintered from 1350C to 1530C as recommended procedure by the manufactures. The results of X-ray diffraction showed that the blocks presented just the tetragonal phase. The blocks were veneered with CZR-Cerabien Zr ceramic (Noritake shinmachi, Nishi-ku, Nagoya, Japão) and afterwards submitted to mechanical tests. Vickers indentation tests were performed to determine hardness and toughness. The shear loading test was performed by using an universal machine and then evaluate the Vickers hardness of the blocks. The flexural resistance was done in four different points in the bars. The samples were observed by SEM to analyze fractures characteristics. Results: Zirconium showed similar physical and mechanical properties with no statistically significant differences on the hardness and resistance to fracture. Nanocrystalline zirconium showed higher toughness and flexural resistance results when compared with microcrystalline ones. Conclusions: Although the samples of nanocrystaline zirconium showed high values, the materials showed similar Vickers hardness, fracture toughness, flexural strength and shear resistance and all of them can be indicated to be used in dentistry.
124

Resistência de união ao cisalhamento de cimentos resinosos autoadesivos ao esmalte e dentina / Shear bond strength of self-adhesive resin cements to enamel and dentin

Raphaela Farias Rodrigues 11 March 2013 (has links)
O objetivo deste trabalho foi avaliar a resistência de união ao cisalhamento dos cimentos autoadesivos RelyX U100 (3M/ESPE) e RelyX U200 (3M/ESPE) ao esmalte e à dentina, em função de diferentes tratamentos da superfície e comparando-os com o cimento resinoso RelyX ARC (3M/ESPE). Cento e vinte incisivos bovinos foram selecionados, limpos e armazenados em solução supersaturada de timol 0,1% para evitar a proliferação de micro-organismos. As coroas foram separadas das raízes e incluídas com resina epóxica em tubos de PVC. Utilizaram-se lixas de carbeto de silício, sob refrigeração, para obtenção de superfícies vestibulares planas de esmalte e dentina. Após a delimitação das áreas destinadas à cimentação com fitas autocolantes, a amostra foi distribuída em 12 grupos (n = 10) de acordo com o substrato, cimento e realização ou não do condicionamento com ácido fosfórico 37% em E-U100 (esmalte + RelyX U100), EU100-C (esmalte + RelyX U100 + condicionamento ácido), E-U200 (esmalte + RelyX U200), E-U200-C (esmalte + RelyX U200 + condicionamento ácido), E-ARC (esmalte + adesivo + RelyX ARC), E-ARC-C (esmalte + RelyX ARC + condicionamento ácido e adesivo), D-U100 (dentina + Relyx U100), D-U100-C (dentina + RelyX U100 + condicionamento ácido), D-U200 (dentina + Relyx U200), D-U200-C (dentina + RelyX U200 + condicionamento ácido), D-ARC (dentina + primer e adesivo + RelyX ARC) e D-ARC-C (dentina + RelyX ARC + condicionamento ácido e adesivo). Uma matriz de teflon bipartida (3 mm de diâmetro e 2 mm de altura) permitiu a confecção de cilindros dos cimentos coincidentes com as áreas delimitadas. Os testes de resistência ao cisalhamento foram realizados, após 7 dias de armazenagem em saliva artificial, numa máquina de ensaio universal EMIC, a velocidade de 0,5 mm/min e com célula de carga de 50 kg. A análise da fratura foi realizada por meio do microscópio digital portátil. Com caráter ilustrativo, dois espécimes de cada grupo foram observados em microscopia eletrônica de varredura. Os dados foram analisados pelo teste ANOVA - 3 critérios e teste Tukey (5%). Não se observou diferença entre os cimentos RelyX U100 e RelyX U200. No esmalte, o RelyX ARC apresentou maior resistência do que os autoadesivos, porém com o prévio condicionamento ácido da superfície os autoadesivos mostraram-se superiores. Em dentina, não houve diferença significante entre os grupos. A maioria das fraturas foi do tipo adesiva. Considerando as limitações deste estudo, conclui-se que os cimentos resinosos autoadesivos podem ser utilizados em alternativa aos cimentos resinosos convencionais nas situações com pouca ou nenhuma estrutura em esmalte. Quando houver a presença considerável de esmalte deve-se priorizar o emprego dos cimentos resinosos convencionais ou os autoadesivos associados ao condicionamento com ácido fosfórico previamente à cimentação. / The objective of this study was to evaluate the shear bond strength of selfadhesive cements RelyX U100 (3M/ESPE) and RelyX U200 (3M/ESPE) to enamel and dentin, due to different surface treatments and comparing them with resin cement RelyX ARC (3M/ESPE). One hundred and twenty bovine incisors were selected, cleaned and stored in supersaturated solution of 0.1% thymol to prevent the proliferation of micro-organisms. The crowns were separated from the roots and embedded with epoxy resin in PVC tubes. It was used silicon carbide sandpaper under refrigeration for obtaining flat buccal surfaces of enamel and dentin. After the delimitation of cementations areas with adhesive tape, the sample was distributed into 12 groups (n = 10) under the substrate, cement and conducting or absence of etching with 37% phosphoric acid in E-U100 (enamel + RelyX U100), E-U100-C (enamel + RelyX U100 + etching), E-U200 (enamel + RelyX U200), E-U200-C (enamel + RelyX U200 + etching), E-ARC (enamel + adhesive + RelyX ARC), EARC-C (enamel + RelyX ARC + etching and adhesive), D-U100 (dentin + RelyX U100), D-U100-C (dentin + RelyX U100 + etching), D-U200 (dentin + RelyX U200), D-U200-C (dentin + RelyX U200 + etching), D-ARC (dentin + RelyX ARC + primer and adhesive) and D-ARC-C (dentin + RelyX ARC + etching and adhesive). A split Teflon mold (3 mm diameter and 2 mm height) allowed manufacturing of cement cylinders, which coincide with delimited areas. The shear strength tests were performed after 7 days of storage in artificial saliva, a universal testing machine EMIC, speed 0.5 mm/min and load cell of 50 kg. The analysis of the fracture was performed using the portable digital microscope. With illustrative, two specimens of each group were observed in scanning electron microscopy. Data were analyzed by ANOVA - 3 criteria and Tukey test (5%). No difference was observed between selfadhesive cements RelyX U100 and RelyX U200. In enamel, the RelyX ARC showed higher resistance than the self-adhesive, but with the prior etching of the surface selfadhesive proved superior. In dentine, no significant difference between groups. Most fractures were type adhesive. Considering the limitations of this study it is concluded that the self-adhesive resin cements can be used as an alternative to conventional resin cements in situations with little or no enamel structure. When there is a considerable presence of enamel should prio ritize the employment of conventional resin cements or self-adhesive associated with phosphoric acid etching prior to cementation.
125

Resistência de união entre cimentos resinosos e zircônia / Bond strenght between resin cements and zirconia

Juan Rommel Medina Valdivia 18 August 2011 (has links)
Este estudo avaliou a resistência de união de cimentos resinosos à zircônia tetragonal parcialmente estabilizada com ítrio (NobelProceraTM Zircônia) submetida a tratamentos superficiais mecânicos e químicos. Os cimentos utilizados foram o cimento resinoso auto-condicionante de polimerização química Multilink (Ivoclar Vivadent) associado ao Metal/Zirconia Primer (Ivoclar Vivadent) e o cimento resinoso auto-adesivo de polimerização química e dual RelyX U100 (3M-ESPE) associado ao adesivo Adper Single Bond Plus 2 (3M-ESPE). Utilizando 40 cilindros de zircônia (diâmetro de 3,5 mm) foram realizados 120 ensaios (n=40 para cada cimento). Para cada cimento os cilindros foram divididos em 4 grupos (n=10) em função do tratamento superficial avaliado: 1- sem tratamento; 2- agente de união (primer ou adesivo); 3- jateamento com oxido de alumínio 50µm; 4- associação do jateamento e o agente de união. A aplicação do cimento resinoso foi realizada utilizando uma matriz de teflon com orifício central de 3,5mm de diâmetro por 3,0mm de profundidade. Após a aplicação de cada cimento nas 4 condições de superficie, os espécimes foram armazenados em água deionizada a 37ºC durante 24h e submetidos ao teste de resistência ao cisalhamento. Os resultados foram analisados com ANOVA a dois critérios e teste de Tukey (p<0,05). Sem tratamento superficial o RelyX U100 químico (5,52 Mpa) e dual (6,53 Mpa) tiveram melhor comportamento que o cimento Multilink (0,76). A associação do jateamento e o agente de união melhorou os valores de resistência de união para o cimento Multilink (7,68 Mpa) e para o cimento RelyX U100 dual (10,26 Mpa), sendo este último superior a todos os outros grupos. A associação do Adper Single Bond Plus 2 e o RelyX U100 sem jateamento, deve ser evitado. / The aim of this study was to evaluate the shear bond strength of resin cements to the yttria stabilized tetragonal zirconia (NobelProceraTM Zirconia) subjected to mechanical and chemical surface treatments. The cements used were: a self-etching resin cement with chemical polymerization Multilink (Ivoclar - Vivadent) associated to the Metal / Zirconia Primer (Ivoclar - Vivadent) and self-adhesive resin cement with chemical and dual polymerization RelyX U100 (3M-ESPE) associated to the adhesive Single Bond Plus Adper 2 (3M-ESPE). Using 40 cylinders of zirconia (3.5 mm diameter) were performed 120 trials (n = 40 for each cement). For each cement, cylinders were divided into four groups (n = 10) based on the surface treatment rated: 1 - untreated, 2 - bonding agent (primer or adhesive) 3 air abrasion with 50µm aluminum oxide, 4 - combination of air abrasion and bonding agent. The application of resin cement was performed using a teflon matrix with a central hole 3.5 mm in diameter and 3.0 mm deep. After application of each cement in the four surface conditions, the specimens were stored in deionized water at 37 ° C for 24 hours and tested for shear bond strength. Results were analyzed with an ANOVA Two Criteria and Tukey\'s test (p <0.05). Without surface treatment, chemical RelyX U100 (5.52 MPa) and dual (6.53 MPa) had better behavior than Multilink Cement (0.76). The combination of air abrasion and bonding agent improved the bond strength values for Multilink (7.68 MPa) and for RelyX U100 dual (10.26 MPa), this one superior to all other groups. The association of Adper Single Bond 2 and RelyX U100 Plus without air abrasion, should be contraindicated.
126

Resistência de união à cerâmica ZLS em diferentes tempos de condicionamento ácido e protocolos de cimentação, após envelhecimento / Bond strength to ZLS ceramic at different etching times and cementation protocols after aging

Thiesen, Kevelin Poliana Palma Rigo 10 February 2017 (has links)
Submitted by Edineia Teixeira (edineia.teixeira@unioeste.br) on 2018-02-27T18:11:32Z No. of bitstreams: 2 Kevelin_Thiesen2017.pdf: 1442804 bytes, checksum: 8c958df12636d1ff3918d68d7e355aa7 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2018-02-27T18:11:32Z (GMT). No. of bitstreams: 2 Kevelin_Thiesen2017.pdf: 1442804 bytes, checksum: 8c958df12636d1ff3918d68d7e355aa7 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2017-02-10 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Objective. To assess the influence of two etching times, three different cementation protocols, and thermal cycling aging on the bond strength between a zirconia-reinforced lithium silicate ceramic and an adhesive resin cement. Method. Ceramic blocks were sectioned in 120 slices with thickness of 1.4 mm and randomly distributed in 12 groups (n = 10). After 5% hydrofluoric acid etching for 20 or 30 s, the adhesive area was delimited with a duct tape and silanized. Resin cement cylinders were cemented from a Teflon mold, following three different combinations: Silane (Si) + Cement (Ci), Si + Adhesive (Ad) + Ci, and Ad + Ci. After photopolymerization through the ceramic, the samples were stored in deionized water at 37°C for 7 days, and then subjected to the microshear bond strength test. Results. After the normality test, data were analyzed by ANOVA, showing statistical difference (p<0.01) for the three factors isolated, the double interaction between the factors of etching time and thermal cycling (p<0.05), and the triple interaction of the factors (p<0.05). Significance. The 5% hydrofluoric acid etching for 30 s and the use of the cementation protocol Scotchbond™ Universal Adhesive + RelyX™ Ultimate Cement presented higher adhesive bond strength after thermal aging, for Suprinity™ ceramics. / Objetivo. Avaliar a influência de, dois tempos de condicionamento ácido, três diferentes protocolos de cimentação e do envelhecimento por ciclagem térmica, na resistência de união entre a cerâmica de silicato de lítio reforçada com zircônia e um cimento resinoso adesivo. Método. Blocos cerâmicos foram seccionados em 120 fatias com 1,4 mm de espessura e distribuídos aleatoriamente em 12 grupos (n = 10). Após o condicionamento com ácido fluorídrico à 5% por 20 ou 30s, a área adesiva foi delimitada com fita isolante e silanizada. Cilindros de cimento resinoso foram cimentados a partir de uma matriz de teflon, seguindo três diferentes combinações: Silano (Si) + Cimento (Ci), Si + Adesivo (Ad) + Ci e Ad + Ci. Após a fotopolimerização através da cerâmica, as amostras foram armazenadas em água deionizada a 37o C durante 7 dias e então submetidas ao teste de resistência de união ao microcisalhamento. Resultados. Após teste de normalidade, os dados foram analizados pelo teste ANOVA mostrando que houve diferença estatística (p<0.01) para os três fatores isolados; para a interação dupla entre os fatores tempo de condicionamento ácido e termociclagem (p<0.05), e também para a interação tripla dos fatores (p<0.05). Significância. O condicionamento com ácido fluorídrico a 5% durante 30 s e a utilização do protocolo de cimentação Adesivo Scotchbond™ Universal + Cimento RelyX™ Ultimate, apresentou maior resistência de união adesiva após o envelhecimento térmico, para a cerâmica Suprinity®.
127

Avaliação da resistência de união entre cimento e uma vitro cerâmica condicionada com diferentes tempos de ácido fluorídrico 5% e 10% - estudo in vitro / Assessment of bond strength between a cement and a glass-ceramic etched at different times with 5% and 10% hydrofluoric acid - in vitro study

Veronese, Carolina Bauer Godoy 23 May 2017 (has links)
Submitted by Rosangela Silva (rosangela.silva3@unioeste.br) on 2018-05-28T12:46:38Z No. of bitstreams: 2 Carolina Bauer Godoy Veronese.pdf: 1949543 bytes, checksum: 5867490bfd176654b3782263890bdf9a (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2018-05-28T12:46:38Z (GMT). No. of bitstreams: 2 Carolina Bauer Godoy Veronese.pdf: 1949543 bytes, checksum: 5867490bfd176654b3782263890bdf9a (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2017-05-23 / Objective: to assess the effect of different hydrofluoric acid (HF) etching times at concentrations of 5% and 10% on the bond strength of RelyX Ultimate resin cement to a zirconia-reinforced lithium silicate ceramic of commercial brand Vita Suprinity (VS), for which the manufacturer recommends using 5% HF for 20". Method: experimental and completely randomized study with 8 treatments (n=8). Each ceramic sample was etched with hydrofluoric acid (HF) at different times and concentrations: 5% for 20, 30, 40, and 60 s, and 10% for 10, 20, 30, and 40 s; subjected to roughness (Ra) analysis, followed by the cementation protocol applying hydrofluoric acid, RelyX Ceramic Primer silane, Single Bond Universal adhesive, and RelyX Ultimate resin cement. Bond strength was assessed by the microshear test followed by fracture pattern analysis. Results: the 5%/20" treatment showed the statistically lowest bond strength of 21.96 MPa (p<0.01), differing from 10% HF treatment at the four times studied: 10" = 29.59 MPa, 20" = 29.77 MPa, 30" = 29.68 MPa, and 40" = 30.78 MPa (p<0.01). The 10%/40" treatment showed the highest bond strength (30.78 MPa), differing only from 5%/20" (21.96 MPa). The fracture pattern was predominantly adhesive. Conclusion: hydrofluoric acid etching increases surface roughness of the Vita Suprinity ceramic at both concentrations and their different times of exposure, showing significant differences in adhesive bond strength only when concentration and etching time vary widely, and with mostly adhesive rupture occurring in the adhesive interface. The concentration of 5% hydrofluoric acid for 30" or 10% for 10" or 20" showed higher bond strength than the manufacturer's protocol, but there were no wide and shallow porosities in SEM. This suggests the increase in exposure time recommended by the manufacturer from 20" to 30" or the use of higher concentrations of acid, such as 10% at 10" or 20", for more effective results. / Objetivo: Avaliar o efeito de diferentes tempos de condicionamento com ácido fluorídrico (HF) nas concentrações de 5% e 10 % na resistência de união do cimento resinoso RelyX Ultimate a uma cerâmica de silicato de lítio reforçada com zircônia de nome comercial Vita Suprinity (VS), onde a indicação do fabricante é a utilização de HF a 5% durante um tempo de 20”. Metodologia: Estudo realizado com delineamento experimental inteiramente casualizado, com 8 tratamentos (n=8). Cada espécime de cerâmica foi condicionado com ácido fluorídrico (HF) em diferentes tempos e concentrações: 5% por 20, 30, 40 e 60 seg, e 10% por 10, 20, 30 e 40 seg; submetidas à análise da rugosidade (Ra), seguido pelo protocolo de cimentação empregando ácido fluorídrico, silano RelyX Ceramic Primer, adesivo Single Bond Universal e cimento resinoso RelyX Ultimate. A resistência de união foi avaliada pelo teste de microcisalhamento; seguido pela análise do padrão das fraturas. Resultados: O tratamento 5%/20” exibiu estatisticamente a menor resistência de união 21,96 MPa (p<0.01), diferindo do tratamento com HF a 10% nos quatro tempos estudados, 10” = 29,59 MPa, 20” = 29,77 Mpa, 30”= 29,68 Mpa e 40”= 30,78 Mpa (p<0.01); o tratamento 10%/40” exibiu a maior resistência de união (30,78 MPa), diferindo apenas do 5%/20” (21,96 MPa). O padrão de fraturas foi predominantemente adesivo. Conclusão: O condicionamento com ácido fluorídrico, em ambas concentrações e em seus diferentes tempos de exposição, aumenta a rugosidade da superfície da cerâmica Vita Suprinity, havendo diferenças significativas na resistência da união adesiva apenas quando a concentração e o tempo de condicionamento variam grandemente, e a maioria da ruptura foi adesiva, ocorrendo na interface do adesivo; com ácido fluorídrico na concentração de 5% durante 30” ou 10% por 10” ou 20” observou-se maior resistência de união do que o protocolo do fabricante, contudo sem observar porosidades amplas e rasas em MEV, sugerindo aumentarmos o tempo de exposição sugerido pelo fabricante de 20” para 30” ou utilizar ácido com concentração maior, como por exemplo 10% em 10” ou 20”, para resultados mais efetivos.
128

Influência do teor de bentonita na condutividade hidráulica e na resistência ao cisalhamento de um solo arenoso utilizado como barreira impermeabilizante / Influence of the bentonita content on the hydraulic conductivity and shear strength of sandy-soil used for liners

Juliana Azoia Lukiantchuki 29 June 2007 (has links)
A utilização de solo natural misturado com bentonita empregado em camadas impermeáveis para retenção de contaminante é bastante comum em aterros sanitários. Neste trabalho, serão apresentados os resultados de ensaios com misturas de solo-bentonita nos teores de 3%, 5% e 7%, utilizando-se um solo arenoso proveniente da região de Pindorama (SP). Os ensaios de condutividade hidráulica para o solo-bentonita foram realizados em permeâmetros de parede flexível. Os resultados obtidos indicam que para os teores de 5% e 7% de bentonita a condutividade hidráulica apresenta-se com valores adequados para a construção de barreiras impermeáveis. A resistência ao cisalhamento do solo compactado puro e das misturas compactadas foi avaliada através de ensaios triaxiais do tipo consolidado não drenado (CU) e ensaios de compressão simples. A coesão efetiva e o ângulo de atrito efetivo do solo aumentou e diminuiu, respectivamente, com a adição de bentonita. Os ensaios de resistência à compressão simples para as misturas com 5% de bentonita atingiram valores aceitáveis para o emprego em camadas impermeabilizantes. / It is becoming very common the use of soil-bentonite mixtures for building sanitary landfill liners with the purpose of retaining pollutants. This work shows the results of hydraulic conductivity and shear strength tests performed with soil-bentonite mixtures with 3%, 5% and 7% bentonite content. The natural soil was gathered in the Pindorama area, which is located in the northeast of Sao Paulo state. The hydraulic conductivity tests were performed in a flexible wall permeameter. Test results show that mixtures with 5% and 7% bentonite content are suitable, in terms of hydraulic conductivity, for construction of sanitary landfill liners. The shear strength parameters of natural soil and mixtures have been assessed performing undrained triaxial compression tests and unconfined compression tests. The effective cohesion and the effective friction angle increased and decreased with the increase of the bentonite content, respectively. The unconfined compression test results have shown that mixtures with 5% bentonite content are suitable, in terms of shear strength, for construction of sanitary landfill liners.
129

Análise de resistência ao cisalhamento de interface em caldas de cimento e caldas de solo-cimento para utilização em solos grampeados / Interaction soil-nailed: comparison of the results of field with the laboratory tests

Juliana Maria Félix de Lima 29 October 2009 (has links)
Dentre as técnicas de reforço de solos, o solo grampeado têm se destacado em âmbito mundial devido a sua versatilidade e eficiência na estabilização de taludes de escavação por meio do reforço do solo \"in situ\", através da introdução de gramposno meio a ser estabilizado. A resistência ao cisalhamento na interface solo-grampo é um dos parâmetros mais importantes a serem analisados. Esta pode ser obtida por meio de ensaios de arrancamento. No entanto, como estes ensaios devem serexecutados durante a execução das obras, existe uma grande aplicação de estimativas da resistência por atrito lateral, baseada em correlações empíricas. Este trabalho realiza a previsão da resistência ao cisalhamento da interface solo-calda quefoi avaliada experimentalmente por meio de ensaios de cisalhamento direto realizados em laboratório. Estes ensaios permitiram uma análise dos parâmetros de resistência dos solos (c e \'fi\') e das interfaces solo-calda. Adicionalmente, foramelaborados traços alternativos de caldas solo-cimento de modo a avaliar sua aplicabilidade na técnica de solo grampeado. Os resultados permitiram constatar que o uso de solo-cimento em substituição a calda de cimento convencional é viável, vistoque os resultados apresentaram um ganho de resistência ao cisalhamento de interface. Os valores de resistência de interface obtida em laboratório apresentaram resultados próximos aos valores de campo, obtidos a partir da realização dos ensaiosde arrancamento em obras distintas. / Among the techniques to enhance soil, the nailing soil have been highlighted in the world due to its versatility and efficiency in the stabilization of excavation\'s slopes by means of the strengthening of the soil in situ by the introduction ofnails in the environment that it wanted to stabilize. The shear strength at the interface soil-nailed is one of the most important parameters to be analyzed. This can be obtained by pullout testing. However, these tests should be performedduring the construction activities, there is a great application of estimates of resistance by lateral friction, based on empirical correlations. This study evaluates the prediction of the strength to shear in the soil-grout interface which was experimentally evaluated by means of direct shear tests performed in the laboratory. These tests allowed an analysis of the parameters of resistance of the soils and of the soil-grout interfaces. Additionally, it was developed alternative batches of soil-cement grouts to assess its applicability in the technique of soil nailing. The outcomes allowed conclude to the use of soil-cement in place of the conventional cement grout is feasible, because the results presented aconsiderable gain in shear strength of interface. The values resistance of the interface obtained in the laboratory showed similar results to the values of the field, obtained from the pullout testing in different construction sites.
130

Avaliação da resistência ao cisalhamento em GCLs - uma nova metodologia de ensaio / GCL shear strength evaluation - a new test method

Victor Eduardo Pimentel 14 March 2008 (has links)
Os GCLs (Geosynthetic Clay Liners) são materiais geossintéticos destinados a compor sistemas de controle de fluxo em obras geotécnicas e ambientais. Suas propriedades vêm sendo cada vez mais estudadas visando a avaliação de seu comportamento de curto e longo prazo. Dentre as propriedades mais importantes de um GCL, está a sua resistência ao cisalhamento interno, tendo em vista que o seu principal componente, a bentonita, possui baixa resistência quando hidratada. Este trabalho apresenta o desenvolvimento de uma nova metodologia de ensaio-índice para estimativa da resistência ao cisalhamento em GCLs - o método CTM (cisalhamento por tração modificado). A principal inovação do método proposto é o formato \"U\" da garra para fixação dos corpos-de-prova. Foram executadas duas séries de ensaios, nas quais, realizou-se uma seleção criteriosa das amostras e um plano de preparação dos corpos-de-prova, de forma a evitar que a variabilidade inerente à fabricação dos GCLs, influenciasse nos resultados obtidos. A primeira fase de testes foi realizada com o objetivo de se correlacionar os resultados do método CTM com dois outros métodos de ensaios-índice existentes: ensaio de adesão (peeling-test) e ensaio de cisalhamento por tração (shear-tensile test). Os resultados obtidos apresentaram boa correlação e o método CTM se mostrou bastante prático. A segunda série de ensaios foi realizada visando aprimorar a montagem do ensaio CTM e comparar os seus resultados com ensaios de cisalhamento direto. Novamente as metodologias se correlacionaram bem, o que justifica o desenvolvimento do método CTM. / GCLs (Geosynthetic Clay Liners) are geosynthetic products used to compose flux control barriers in geotechnical and environmental works. The mechanical properties of GCLs have to be investigated in short and long term. Among its mechanical parameters, GCL internal shear strength plays an important role in the stability of slopes of geotechnical works. The main component of a GCL, the bentonite, when hydrated, presents very low shear strength. This work presents the development of a new index test method that aims cheaply and quickly to estimate the shear strength of GCLs - the CTM method (modified shear-tensile test). The main innovation of the proposed method is the U-shape grip that imposes a state of deformation close to that observed in field works. Two series of tests were performed in which a careful selection of samples and specimens were done. This aimed to minimize variation effects, inherent to the GCL production, on the obtained results. The first series was carried out to correlate results from the CTM tests to other two index tests: peel test and shear-tensile test. The results showed a good correlation between CTM and the other test results. The second series of tests was planned to improve CTM test method in order to get even better results than peel or shear-tensile tests, apart from correlating its results to results of direct shear test. Comparisons of results show very good agreement what justifies the use of the cheaper and quicker CTM method.

Page generated in 0.1551 seconds