• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 261
  • 5
  • 5
  • 5
  • 5
  • 4
  • 3
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 265
  • 265
  • 265
  • 169
  • 160
  • 56
  • 49
  • 48
  • 43
  • 43
  • 41
  • 37
  • 31
  • 30
  • 29
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
91

Resistência ao microcisalhamento de diferentes sistemas adesivos no esmalte dental humano

Nagayassu, Marcos Paulo [UNESP] 27 June 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:25Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-06-27Bitstream added on 2014-06-13T21:02:25Z : No. of bitstreams: 1 nagayassu_mp_dr_sjc.pdf: 569285 bytes, checksum: 26edda3951c5eb0e27050fe830c365f3 (MD5) / O objetivo deste estudo foi avaliar in vitro a resistência ao microcisalhamento de 5 sistemas adesivos ao esmalte, sendo 1 adesivo monocomponente (M), 2 primers autocondicionantes (P) e 2 adesivos autocondicionantes (A). Foram utilizadas 60 faces (vestibular ou lingual) de pré-molares, aplainadas com lixas d'água (400 e 600) e divididas aleatoriamente em 5 grupos (n=12), de acordo com o adesivo utilizado: SB2- Single Bond2 (M); CSE- Clearfil SE Bond (P); ADS- AdheSE (P); PLP- Adper Prompt L-Pop (A); XE3- Xeno III (A). Tubos de Tygon delimitaram a área de adesão em 0,8mm de diâmetro, para se obter os cilindros de resina composta (Z250). Após armazenamento em água destilada a 37ºC por 24h e termociclagem, foi realizado o teste de microcisalhamento (velocidade de 0,5mm/min).). Os dados foram submetidos aos testes de ANOVA e Tukey ('alfa'=5%). Os valores de média (MPa'mais ou menos'DP) e os resultados do teste de Tukey foram: SB2: 36,36('mais ou menos'3,34)a; ADS: 33,03('mais ou menos'7,83)a; XE3: 32,76('mais ou menos'5,61)a; CSE: 30,61('mais ou menos'6,68)a; PLP: 22,17('mais ou menos'6,05)b. Grupos com a mesma letra não apresentaram diferenças significantes. Pode-se concluir que não houve diferença estatística entre SB2, ADS, XE3 e CSE, apesar dos diferentes padrões de condicionamento destes adesivos. Apenas o PLP apresentou valores médios de adesão inferiores aos demais. / The aim of this in vitro study was to evaluate the micro-shear bond strength of 5 adhesive systems to enamel, one single-bottle acid-etch adhesive (O), two selfetching primers (P) and two all-in-one self-etching adhesives (S). Sixty premolar enamel surfaces (buccal or lingual) were ground flat with 400- and 600-grit SiC papers and randomly divided into 5 groups (n=12), according to adhesive system: SB2 - Single Bond 2 (O); CSE - Clearfil SE Bond (P); ADS - AdheSE (P); PLP - Adper Prompt L-Pop (S); XE3 - Xeno III (S). Tygon tubing (internal diameter of 0,8mm) restricted the bonding area to obtain the resin composite (Z250) cylinders. After storage in distilled water at 37oC for 24h and thermocycling, micro-shear testing was performed (crosshead speed of 0.5mm/min). Data were submitted to one-way ANOVA and Tukey test ('alfa'=5%). Mean bond strength values (MPa'mais ou menos'SD) and the results of Tukey test were: SB2: 36.36('mais ou menos'3.34)a; ADS: 33.03('mais ou menos'7.83)a; XE3: 32.76('mais ou menos'5.61)a; CSE: 30.61('mais ou menos'6.68)a; PLP: 22.17('mais ou menos'6.05)b. Groups with the same letter were not statistically different. It can be concluded that no significant difference was there between SB2, ADS, XE3 and CSE, in spite of different etching patterns of these adhesives. Only PLP presented statistically lower bond strengths compared with others.
92

Análise in vitro da resistência de união ao cisalhamento de uma resina composta à dentina humana e à bovina, tratadas com diferentes adesivos

Magnani, Cristina [UNESP] January 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:27Z (GMT). No. of bitstreams: 0 Previous issue date: 2006Bitstream added on 2014-06-13T20:22:10Z : No. of bitstreams: 1 magnani_c_dr_arafo.pdf: 594008 bytes, checksum: d8496d3440da8bb7f9fe9acf656211c7 (MD5) / O presente trabalho teve por objetivo avaliar, comparativamente, in vitro, a resistência de união ao cisalhamento de uma resina composta à dentina humana e à dentina bovina, submetidas ao tratamento com dois sistemas adesivos convencionais simplificados (Prime Bond NT®, Dentsply e Single Bond®/3M) e dois sistemas adesivos autocondicionantes (AdheSE®/Ivoclar-Vivadent e Adpper Prompt-L-Pop®/ 3M). Para a confecção dos corpos-de-prova, foram utilizadas as superfícies vestibulares de 40 dentes molares humanos e de 40 dentes incisivos bovinos, as quais foram divididas aleatoriamente em 8 grupos de 10 amostras cada, de acordo com o tipo de substrato e o sistema adesivo utilizado: Grupo 1 - dentina humana tratada com o sistema adesivo Single Bond; Grupo 2 - dentina humana tratada com o sistema adesivo Prime Bond NT; Grupo 3 - dentina humana tratada com o sistema adesivo AdheSE; Grupo 4 - dentina humana tratada com o sistema adesivo Adpper Prompt-L-Pop; Grupo 5 - dentina bovina tratada com o sistema adesivo Single Bond; Grupo 6 - dentina bovina tratada com o sistema adesivo Prime Bond NT; Grupo 7 - dentina bovina tratada com o sistema adesivo AdheSE; Grupo 8 - dentina bovina tratada com o sistema adesivo Adpper Prompt-L-Pop. Após o tratamento das superfícies, com o auxílio de uma matriz bipartida, foram confeccionados cilindros de resina composta Tetric Ceram apresentando 3mm de diâmetro e 4mm de altura. Os corpos-de-prova foram então armazenados em água destilada a 37ºC por 24 horas e submetidos a termociclagem (550 ciclos à temperatura de 10ºC e 55ºC). Após 48 horas de armazenamento em água destilada a 37ºC, foram levados a uma Máquina de Teste Universal para a realização do teste de cisalhamento utilizando-se uma ponta em forma de cinzel e velocidade do atuador de 0,5 mm/min. Os tipos de fratura foram analisados em lupa estereoscópica com 40X de aumento. / The purpose of this in vitro study was to evaluate, comparatively, the shear bond strength of a composite resin to human and bovine dentin treated with two conventional simplified adhesive systems (Prime Bond NT®/Dentsply and Single Bond®/3M) and two self-etching adhesive systems (AdheSE®/Ivoclar-Vivadent and Adpper Prompt-L-Pop®/3M). For preparation of specimens, the buccal surface of 40 human molars and 40 bovine incisors were obtained and randomly assigned to 8 groups (n=10), according to the type of substrate and adhesive system used. Group1 - human dentin treated with Single Bond; Group 2 - human dentin treated with Prime Bond NT; Group 3 - human dentin treated with AdheSE; Group 4 - human dentin treated with Adpper Prompt-L-Pop; Group 5 - bovine dentin treated with Single Bond; Group 6 - bovine dentin treated with Prime Bond NT; Group 7 - bovine dentin treated with AdheSE; Group 8 - bovine dentin treated with Adpper Prompt-L-Pop. After treatment with the adhesive systems, composite resin (Tetric Ceram) cylinders (3 mm in diameter and 4 mm high) were fabricated using a split matrix and were bonded to the dentin surfaces. The specimens were stored in distilled water at 37ºC for 24 hours and then submitted to a thermocycling regimen (550 cycles between 10ºC and 55ºC). After 48-hour storage in distilled water at 37ºC, the specimens were taken to a universal testing machine and loaded in shear strength until failure using knife-edge-shearing blade running at a crosshead speed of 0.5 mm/min. Failure mode was analyzed using a stereomicroscope at X40. Data were submitted to statistical analysis by analysis of variance at 5% significance level. The results showed that Single Bond and Prime Bond NT adhesive systems presented similar shear bond strength to each other (p>0.05) and significantly higher means than AdheSE and Adper Prompt-L-Pop (p<0.05), regardless of the type of substrate.
93

Resistência mecânica da madeira de eucalyptus saligna unidas por adesivo poliuretano para diferentes acabamentos de superfície

Silva, Reinaldo Sebastião [UNESP] 05 November 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:50Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-11-05Bitstream added on 2014-06-13T19:03:29Z : No. of bitstreams: 1 000741204.pdf: 3581224 bytes, checksum: e0cd70ba05493c746b3dd276c6b9a5d1 (MD5) / O presente trabalho teve como objetivo, verificar o desempenho de juntas coladas em função do acabamento das superfícies usinadas em operações de fresamento para diferentes velocidades de avanço e de lixamento para diferentes granulometrias de lixa, empregando-se madeira da espécie Eucalyptus saligna. Para tanto, foram confeccionadas amostras para ensaios normatizados pela Norma ABNT - NBR 7190, submetidas a testes de resistência a ruptura na linha de cola por esforços de cisalhamento e por tração normal. Na união das peças de madeira para confecção das amostras utilizou-se dois tipos de adesivos à base de resina poliuretano (PU), denominados neste estudo por “PU monocomponente” e “PU bicomponente”. Na preparação das superfícies para aplicação dos adesivos, o primeiro grupo de amostras foi usinado por operação de fresamento cilíndrico tangencial empregando-se três velocidades nominais de avanço “Vf” de 6,0; 11,0 e 15,0 m/min, o segundo grupo de amostras foi usinado por operação de lixamento empregando-se cinco granulometrias de lixas, granas: 80, 100, 120, 150 e 220. Dos resultados obtidos podem-se destacar os melhores desempenhos de resistência a ruptura; para superfícies fresadas: ao cisalhamento com Vf = 6,0 m/min com adesivo PU monocomponente e Vf = 15,0 m/min com adesivo PU bicomponente, à tração normal com Vf = 11,0 m/min para ambos adesivos PU; para superfícies lixadas: ao cisalhamento com lixa de grana 100 e à tração normal com lixa de grana 80, para ambos os adesivos PU / The present work had as the main goal, to verify the performance of glued joints for finishing touch of machined surfaces in operations of milling for different speeds of advance and of fine sanding for different granulometry of sandpaper, using wood of the Eucalyptus saligna type. For that; samples have been manufactured for the experiments regulated by the ABNT rule – NBR 7190, subjected to tests of resistance to the rupture of the glue line for efforts of degloving and for the normal traction. In the union of the wooden parts to make the samples 2 types of polyurethane based adhesives (PU) were used, named in this study Mono component PU and Bi component PU. In the preparation of the surfaces for the application of the adhesives, the first group of the samples was machined by the operation of cylindrical tangential milling employing three nominal advance speed “Vf” of 6,0; 11,0 and 15,0 m/min, the second group of samples was machined by the operation of sanding employing five types of sandpaper granulometry, grains: 80, 100, 120, 150 and 220. From the obtained results it is possible to point out the best performances from resistance to rupture; for the milled surfaces: to the degloving with Vf = 6,0 m/min with the PU Mono component and Vf = 15,0 m/min with the PU Bi component, to the normal traction Vf = 11,0 m/min for both PU adhesives; for the sanded surfaces: to the degloving with a 100 grain sandpaper and to the normal traction with the 80, for both PU adhesives
94

Estudo comparativo in vivo e in vitro da resistência ao cisalhamento de braquetes metálicos colador com resina polimerizada com luz halógena e LEd

Penido, Sérgio Milton Martins de Oliveira [UNESP] 30 May 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:22Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-05-30Bitstream added on 2014-06-13T19:44:08Z : No. of bitstreams: 1 penido_smmo_dr_arafo.pdf: 996491 bytes, checksum: 142106818d9d76c3991a99fe95fe589a (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este trabalho teve como objetivo avaliar a resistência ao cisalhamento, in vivo e in vitro, de braquetes metálicos (Abzil Lancer) colados em dentes humanos com material adesivo polimerizado xom luz halógena e LED. Os braquetes foram cotados em 60 pré-molares formando seis grupos. Nos Grupos I e II os braquetes foram colados nos segundos pré-molares respectivamente no lado direito e esquerdo dos pacientes. A polimerização do material adesivo foi com a luz de LED epara o GI e luz halógena para o GII. Nos demais grupos os braquetes foram colados em primeiros pré-molaressuperiores e inferiores extraídos por motivos ortodônticos. A polimerização realizada nos grupos III e V foi com o aparelho de LED enquanto que nos grupos III e V foi com o aparelho de LED enquanto que nos grupos IV e VI com luz halógena. Nos Grupos I e II testes de cisalhamento foram realizados utilizando-se dinamômetro sigital portátil diretamente na boca dos pacientes. Os grupos IIII, IV, V e VI foram armazenados em água destilada e levados a estufa a 37ºC por 24 horas e posteriormente, submetidos a termociclagem, com 1000 ciclos a 5 e 55ºC. Posteriormente, nos grupos III e IV, utilizou-se máquina universal de ensaios mecânicos e nos grupos IV e VI os ensaios mecânicos foram realizados com dinamômetro digital. Os valores médios da resistência ao cisalhamento em Mpa foram de: GI = 3,65; GII = 4,39; GIII = 6,45; GIV = 7,11; GV = 4,67; GVI = 4,21. Após a descolagem foram realizadas fotografias Das áreas de colagem. As imagens obtidas foram ampliadas %x, analisadas e classificadas de acorso com o índice de Adesivo Remanescente (IAR). Os resultados dos testes mecânicos in vivo ou in vitro. Os testes realizados com equipamento portátil digital tiveram valores médios significativamente menores em relação áqueles realizados em máquina de ensaios mecânicos universal. Não houve relação definida entre carga de ruptura e tipo de falha. / This work as a purpose to assess the shear bond strength, in vivo and in vitro , of metallic brackets (Abzil lancer) bondedto human teeth with light-curing bonding material with halogen and led lights. The brackets were bonded to 60 premolars, so forming 6 groups.In GI and II the brackets were bonded to second premolars, resectively, on the right and left sides of the patients. The polymerization of the bonding material was with LED light for GI and halogen light for GII. In the other groups the brackets were bonded to superior and inferior first premolars, extrated for orthodontic reasons. The polymerizatio was performed in GII and V with LED device, while in GIV and VI eith halogen light. In GI and II shear strength tests were made using a portable digital dynamoter directly in the patients' mouths. GII, IV, V and VI were stored in distilled water and taken to sterilizer at 37ºC for 24 hours, and afterwards, submitted to thermocycling with 1000 cycles at 5 and 55 º. Then, in GIII and IV, the Universal testing machine was used and in GIV and VI the mechanical tests were performed with a digital dynamometer. The average values of shear strength in Mpa were: GI=3,65; GII=4,39; GIII=6,45; GIV=7,11; GV=4,67 and GVI=4,21. Pictures of thebonding areas were taken after the tests. The images obtained amplified 5 times, analyzed and classified, according to Adhesive remaining index (IAR). The results suggested that the LED light or the halogen light did not interfere in the results of the mechanical tests in vivo or in vitro. The tests performed with a portable digital device obtained average values significantly lower than those performed with Universal testing machine. There was no definite relation between shear bond strengths and kind of failure.
95

Avaliação de protocolos para colagem de bráquetes cerâmicos e remoção do adesivo remanescente com vistas á preservação da integridade de esmalte dentário

Vianna, Alexandre Protásio [UNESP] 08 March 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:23Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-03-08Bitstream added on 2014-06-13T19:07:08Z : No. of bitstreams: 1 vianna_ap_dr_arafo.pdf: 843063 bytes, checksum: 4531dd78f0e6348ef44fc614df388067 (MD5) / Introdução: Este estudo teve como objetivos: Avaliar a influência de diferentes protocolos de condicionamento do esmalte e de cura luminosa dos sistemas adesivos testados, na resistência da colagem de bráquetes de cerâmica ao cisalhamento; na ocorrência de fraturas de esmalte e na quantidade de adesivo remanescente. Além disso, o Método dos Elementos Finitos foi empregado para analisar como os esforços relativos à descolagem atuaram na superfície do esmalte. Com auxílio da Microscopia eletrônica de varredura, avaliou-se a ação de 05 métodos para remoção da camada de adesivo remanescente quanto às alterações geradas nas características superficiais originais do esmalte e quanto ao tempo de execução dos procedimentos. Material de Método: 40 bráquetes Inspire IceTM, 40 bráquetes ClarityTM e 40 bráquetes GeminiTM foram aleatoriamente colados a 120 pré-molares com faces vestibulares hígidas, seguindo diferentes protocolos de condicionamento do esmalte e de fotopolimerização. Essas colagens foram testadas em ensaio mecânico por cisalhamento e também analisadas pelo método dos elementos finitos. Além disso, 25 molares permanentes com faces vestibulares hígidas passaram pela remoção de camadas padronizadas de adesivo remanescente com 05 métodos diferentes. As superfícies iniciais e finais de cada dente foram avaliadas por meio da microscopia eletrônica de varredura. O tempo gasto na execução de cada procedimento foi também avaliado. Resultados: As colagens com o TPSEP apresentaram menores valores de resistência da colagem ao cisalhamento e não estiveram associadas a fraturas de esmalte. Houve coincidência entre o modo de descolagem dos braquetes e a distribuição dos esforços na superfície do modelo 3D. As menores alterações à superfície do esmalte foram geradas... / Introduction: The aims of this study were to evaluate the influence of different protocols for enamel acidic etching and for light-curing of the adhesive systems tested about: shear bond strength of ceramic brackets; occurrence of enamel fractures and adhesive remnant index. Finite element method was also used to identify how debonding efforts act on enamel surface. Scanning Electron Microscopy was applied to assess the changes observed on original enamel surface characteristics generated by 05 methods for residual adhesive removal. The chair time related to the 05 methods under study was also evaluated. Material and Methods: 40 Inspire Ice Brackets; 40 Clarity Brackets and 40 metal Brackets (Gemini) were randomly bonded to 120 bicuspides, using different protocols of enamel conditioning and photo-activation. 25 permanent molars were submitted to the removal of standardized adhesive layers, using 05 different methods. Initial and final surfaces were comparatively evaluated by scanning electron microscopy. The procedures chair times were also assessed. Results: Transbond Plus Self-etching Primer promoted bracket bonding with lower shear bond strengths and debonding procedures without enamel fractures. FEM analysis showed coincidence among efforts distribution simulated over the tridimensional model surfaces and the real debonding damages caused on enamel. The multi-blade carbide bur in low hand-piece speed caused lower alterations over enamel original surface. Conclusion: TPSEP seemed to be the adequate method for bracket bonding; metallic bracket bonding showed lower shear bond strength without primer light-curing but it was not true for the ceramic brackets; chair time of the procedure and the final aspect of enamel surface demonstrated... (Complete abstract click electronic access below)
96

Avaliação da resistência ao cisalhamento e da durabilidade de união entre sistemas para reparo em metalocerâmicas e titânio

Haneda, Isabella Gagliardi [UNESP] 25 July 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:01Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-07-25Bitstream added on 2014-06-13T19:05:05Z : No. of bitstreams: 1 haneda_ig_dr_arafo.pdf: 1539372 bytes, checksum: 1d44db42b17bfb741258df69baa7591c (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O reparo de restaurações metalocerâmicas fraturadas é uma opção de tratamento que possibilita o aumento da longevidade da restauração, preservando a estrutura dental, além de ser uma alternativa rápida e de menor custo. Entretanto, o estabelecimento de uma união forte e estável entre material reparador e substrato da restauração fraturada é essencial para o sucesso do reparo. Levando-se em consideração a grande utilidade dos reparos quando corretamente indicados e a possibilidade de um aprimoramento dos mesmos com esses novos sistemas, conforme prometem os fabricantes, foi propósito deste estudo avaliar, em titânio comercialmente puro, a resistência ao cisalhamento de quatro sistemas comerciais de reparo para metalocerâmicas e da variação de um destes, bem como a durabilidade de união após armazenamento em água. Foram confeccionados discos (9 × 3 mm) em titânio comercialmente puro. Estes foram incluídos em anel de PVC com resina acrílica e suas superfícies regularizadas com lixas de carbeto de silício de diferentes granulações (120, 220 e 320) em politriz. Os espécimes receberam um dos seguintes tratamentos (n=10): 1) Epricord, 2) Bistite II DC, 3) Cojet, 4) Scotchbond Multi Uso Plus (grupo Controle), e 5) uma variação do grupo Controle, na qual foram empregadas partículas de sílica do sistema Cojet Sand em substituição às de óxido de alumínio. Os espécimes foram armazenados em água destilada a 37ºC por 24 horas, termociclados (5.000 ciclos - 5º e 55ºC) e, então, armazenados nas mesmas condições descritas anteriormente, por um período adicional de 24 horas ou 6 meses. O ensaio de cisalhamento foi realizado em máquina de ensaios Material Test System 810 com velocidade de 0,5 mm/minuto. O modo da fratura foi avaliado em lupa estereoscópica (30x). Às 24 horas, as médias... / Repair is a good alternative treatment that can increase clinical longevity of the failed restoration, preserving tooth structure, with the advantages of less chair time and lower cost. However, the clinical success of repair depends on establishing a strong and longterm durable bond between the repair material and the metal surface of the failed restoration. Considering the great benefit of intra-oral repairs and the possibility of improvement with the use of new available repair systems, the purpose of the present study was to evaluate shear bond strength of different repair systems to commercially pure titanium (CP Ti) and bond durability after long-term water storage. One-hundred disk specimens of cast CP Ti (9 × 3 mm) were embedded in a PVC ring and their bonding surfaces were smoothed with silicon carbide papers (120, 220, and 320 grit) using a polisher. Specimens were divided into 5 groups of 20, which received one of the following repair systems: 1) Epricord, 2) Bistite II DC 3) Cojet, 4) Scotchbond Multipurpose Plus (control Group), and 5) Cojet Sand plus Scotchbond Multipurpose Plus (variation of the control Group). The specimens were stored in distilled water for 24 hours at 37ºC, thermal cycled (5,000 cycles – 5º to 55ºC) and then stored in distilled water at 37o C for either 24 hours or 6 months. Shear bond tests were performed in a mechanical testing machine with a crosshead speed of 0.5 mm/minute. Each specimen was examined under a stereoscopic lens with ×30 magnification. At 24 hours, the mean values (MPa) for the groups 1 to 5 were respectively 13,00 + 2,04c, 8,10 + 1,16d, 18,34 + 2,16b, 13,41 + 1,42c, e 22,73 + 1,42a. After 6 months, the mean (MPa) of each... (Complete abstract click electronic access below)
97

Efeito da desinfecção química e por microondas na alteração dimensional e resistência de união de resinas para reembasamento imediato e resina termopolimerizável

Gonçalves, Andréa [UNESP] 04 April 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:02Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-04-04Bitstream added on 2014-06-13T20:06:12Z : No. of bitstreams: 1 goncalves_ar_dr_arafo.pdf: 1974874 bytes, checksum: cb90cfb07e456ba101c0f7c18597c3d6 (MD5) / Esse estudo avaliou o efeito da desinfecção química e por irradiação com microondas sobre a estabilidade dimensional e a resistência ao cisalhamento entre uma resina termopolimerizável para base de prótese (Lucitone 550-L) e quatro resinas autopolimerizáveis para reembasamento (Kooliner- K, New Truliner-NT, Tokuso Rebase-TR, Ufi Gel Hard -UGH). Foi avaliada também a resistência ao cisalhamento de corpos-de-prova reembasados com a resina L. Para cada material, 48 corpos-de-prova (50 mm diâmetro x 0.5 mm espessura) foram preparados, seguindo-se as recomendações dos fabricantes, utilizando-se uma matriz metálica circular com pontos de referência (A, B, C e D). Um projetor de perfil Nikon foi utilizado para mensurar a distância entre os pontos de referências (AB e CD) na matriz metálica e nos corpos-de-prova. Os corpos-de-prova foram divididos em 6 grupos (n=8) e as mensurações foram realizadas após as seguintes condições experimentais: G1- 2 ciclos de desinfecção química (corpos-de-prova imersos em solução de perborato de sódio a 3,8% aquecida a 50º C por 10 minutos); G2- 2 ciclos de desinfecção com microondas (corpos-de-prova imersos em 200 mL de água e irradiados com 650 W por 6 minutos); G3- 7 ciclos de desinfecção química; G4- 7 ciclos de desinfecção com microondas; C1- grupo controle 1- após a polimerização para as resinas de reembasamento e após imersão em água a 37° C por 48 + 2 horas para a resina de base; C2- grupo controle 2- corpos-de-prova imersos em água a 37° C por 7 dias. Para os grupos G3 e G4, os corpos-de-prova foram mantidos em água a 37° C entre os ciclos de desinfecção. As diferenças entre as mensurações realizadas nos corpos-de-prova e as da matriz foram calculadas e expressas em porcentagem de alteração dimensional linear. Para avaliar a resistência de união, foram confeccionados cilindros... / This study evaluated the effect of chemical and microwave disinfection on the linear dimensional change and the shear bond strength between one heat-polymerizing denture base acrylic resin (Lucitone 550-L) and four autopolymerizing reline resins (Kooliner- K, New Truliner-NT, Tokuso Rebase-TR, Ufi Gel Hard -UGH). Also, the shear bond strength of specimens relined with the denture base resin L was evaluated, for comparison. For each material, 48 disks (50 mm diameter and 0.5 mm thickness) were made by using a stainless steel split mold with reference points (A, B, C and D), following the manufacturers' instructions. A Nikon optical comparator was used to measure the distances between the reference points (AB and CD) on the stainless steel mold and on the specimens. Specimens were divided into 6 groups (n=8) and the measurements were made after the following conditions: G1- 2 cycles of chemical disinfection (specimens immersed in 3,8% sodium perborate solution at 50° C for 10 minutes); G2- 2 cycles of microwave disinfection (specimens immersed in 200 mL of water, and irradiated with 650 W for 6 min); G3- 7 cycles of chemical disinfection; G4- 7 cycles of microwave irradiation; G5- after polymerization for the reline resins and after the specimens had been stored in water at 37° C for 48 + 2 hours; G6- specimens immersed in water at 37° C for seven days. For the groups G3 and G4, the specimens were disinfected daily, and stored in water at 37° C between disinfection. The differences between the measurements made on the specimens and on the stainless steel mold were calculated and expressed as percentage of linear dimensional changes. To evaluate the bond strength, cylinders (20mm x 20mm) of the resin L were processed (in water at 70°C for 90 minutes, and 30 minutes at boiling temperature), according to the manufacturer's instructions ...(Complete abstract, click electronic access below)
98

Resistência de união de reparos de resinas compostas nanoparticuladas e nanohíbridas

Barbosa, Silvia Helena [UNESP] 03 August 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-08-03Bitstream added on 2014-06-13T19:24:20Z : No. of bitstreams: 1 barbosa_sh_dr_sjc.pdf: 825696 bytes, checksum: 7d5f2983aadcc457cc4f6a75eeb2c368 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este estudo analisou o efeito de 2 diferentes tratamentos de superfície na resistência de união de resinas nanoparticuladas antes e após envelhecimento. Blocos (N=128) das resinas Tetric EvoCeram (TE) (Ivoclar) ou Filtek Supreme (FS) (3M ESPE) foram preparados e divididos em 2 grupos: a) controle (sem envelhecimento); b) termociclagem (TC) (x5000, 5-55°C). Os blocos foram novamente divididos em dois grupos, de acordo com o tratamento de superfície: (1) jateamento com óxido de alumínio modificado pro sílica (CoJet, 3M ESPE)+silano (ESPE-Sil)+ Visiobond, (2) adesivo (A). Para o reparo, a mesma resina usada no substrato (FS ou TE) ou resina microhíbrida (Quadrant Anterior Shine, Cavex-QA) foi utilizada. Os espécimes foram submetidos ao teste de cisalhamento ou microtração (1mm/min). Os dados (MPa'mais ou menos'DP) foram analisados com os testes t-Student, ANOVA dois fatores e Tukey. Ensaio de microtração revelou efeito significante no tipo de resina de substrato (p<0.001) e no envelhecimento (p<0.001). Após TC, resina TE (37,6'mais ou menos'12,0) apresentou resistência a microtração significantemente inferior (p<0.05) a FS (45,7'mais ou menos'12,8). TC diminuiu a resistência de união para TE e FS quando comparado com os grupos controle (49,4'mais ou menos'15,6 e 52,2'mais ou menos'17,1, respectivamente). A resina composta usada para o reparo (TE, FS, QA) não afetou significantemente os resultados (p>0,05). Quando o teste de cisalhamento foi aplicado após TC, espécimes tratados com Cojet associado ao silano aumentaram significativamente a resistência de união para FS (21,5) quando comparado com o adesivo (14,8) (p<0,001), mas para TE o adesivo (22,29) foi mais mais efetivo que o Cojet (13,35) (p>0,05). / This study evaluated the effect of 2 different surface conditioning methods on the bond strength of nanofilled composites before and after aging conditions. Blocks (N=160) were prepared from composites namely, Tetric EvoCeram (TE) (Ivoclar) or Filtek Supreme (FS) (3M ESPE) and randomly divided into 2 groups: a) control (no aging); b) thermocycling (TC) (x5000, 5-55°C). The specimens were further assigned to two surface-conditioning methods: (1) Silica-coating (CoJet, 3M ESPE)+silane (ESPE-Sil), (2) Adhesive resin (A). As repair composites either the same material was used as the substrate (FS or TE) or a microhybrid one (Quadrant Anterior Shine, Cavex-QA). The specimens were submitted to either microtensile or shear bond test (1mm/min). Data (MPa'mais ou menos'SD) were analyzed using Student t-test, two-way ANOVA and Tukey's test. Microtensile test showed significant effect of the composite type (p<0.001) and the aging condition (p<0.001). After TC aging, TE composite (37.6'mais ou menos'12) showed significantly lower (p<0.05) microtensile bond strength results than FS (45.7'mais ou menos'12.8). TC decreased the bond strength results both for TE and FS when compared to the non-aged control group (49.4'mais ou menos'15.6 and 52.2'mais ou menos'17.1, respectively). The choice of repair composite (TE, FS, QA) did not significantly affect the results (p>0.05). When shear test was employed on TC aged, repaired specimens, silica coating and silanization significantly increased the bond strength for FS (21.5) when compared to adhesive resin application (14.8) (p<0.001) but for TE, adhesive resin (22.29) was more effective than silica coating (13.35) (p>0.05).
99

Influência da adição de nanopartículas sobre a dureza, resistência à ruptura e deformação permanente de silicone facial submetido ao envelhecimento acelerado

Nobrega, Adhara Smith [UNESP] 20 February 2014 (has links) (PDF)
Made available in DSpace on 2015-03-03T11:52:30Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-02-20Bitstream added on 2015-03-03T12:06:36Z : No. of bitstreams: 1 000795003.pdf: 1118199 bytes, checksum: 98a54dea093e378451b9a2f7d2e032e2 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Apesar de satisfatórias, as próteses maxilofaciais apresentam limitações quanto à estética, conforto e durabilidade. Por isso estudos com o objetivo de melhorar as propriedades desses materiais são incessantes. É comprovada a eficiência da adição de nanopartículas na proteção de silicones, evitando a degradação da sua cor, no entanto a literatura é escassa quando se refere a outras alterações das propriedades físicas causadas no silicone facial. Assim, o objetivo deste estudo é avaliar a influência da adição de nanopartículas na ruptura, deformação permanente e dureza do Silicone Facial Silastic MDX4-4210. Foram confeccionadas 560 amostras em silicone facial, sendo 280 dessas amostras para o teste de ruptura, 140 para o teste de dureza e 140 para o teste de deformação permanente. As nanopartículas adicionadas na confecção das amostras de silicone foram: óxido de zinco (ZnO); sulfato de bário (BaSO4) e dióxido de titânio (TiO2). Para cada teste (exceção do teste de ruptura, no qual a quantidade de amostras será confeccionada em duplicata), 40 amostras de silicone serão confeccionadas com adição de cada um dos tipos de nanopartículas, totalizando 120 amostras; 10 amostras de silicone com tinta a óleo, sem nanopartículas, e 10 amostras somente de silicone .Para cada tipo de nanopartícula adicionada ao silicone facial, 20 amostras foram confeccionadas na concentração de 1% e 20 na concentração de 2%. Para cada concentração de nanopartículas, metade (10 amostras) foi com adição de tinta a óleo e a outra metade sem tinta a óleo. As amostras foram submetidas aos ensaios de dureza, resistência à ruptura e deformação permanente, e 1008 horas de envelhecimento acelerado. Os dados obtidos foram submetidos à análise estatística, utilizando-se os testes de nested ANOVA e teste de Tukey. Pode-se... / Although satisfactory, the maxillofacial prostheses present aesthetics, comfort and durability limitations. Therefore, studies with the purpose to obtain better properties of these materials are unceasing. The efficiency of adding nanoparticles to silicon protection is well proven in preventing its color degradation, however the literature is scarce when it comes to other physical property changes with infacial silicon.The aim of this study is to evaluate the influence of nanoparticles addition to hardness, rupture resistance and permanent deformation of Facial Silicone Silastic MDX4-4210. 560 samples of facial silicone were made, 280 for rupture resistance test, 140 for hardness test and 140 for permanent deformation test. Nanoparticles added in the preparation of silicone samples were zinc oxide (ZnO), barium sulfate (BaSO4) and titanium dioxide (TiO2). For each test (except the rupture test, in which the samples are duplicated), 40 samples will be made of silicon added to each type of nanoparticles, totaling 120 samples, 10 samples of silicone with oil paint without nanoparticles, and 10 samples only of silicone (control group). For each type of nanoparticle added to the facial silicone, 20 samples were prepared at a concentration of 1% and 20 at a concentration of 2%. For every concentration of nanoparticles, half (10 samples) were added oil paint and the other half without oil paint. Samples were submitted to testing hardness, rupture resistance and permanent deformation, and 1008 hours of accelerated aging. The data were subjected to statistical analysis using nested ANOVA and Tukey tests. It can be verified through the results that the presence of nanoparticles influenced the hardness, tear strength and permanent deformation of the assessed groups. We conclude that all evaluated nanoparticles influenced the hardness, tear strength and permanent... / FAPESP: 12/05270-3
100

Investigação sobre a resistência ao cisalhamento de um solo residual de gnaisse

Bernardes, Juliana de Azevedo January 2003 (has links)
O solo residual de gnaisse estudado nesta dissertação ocupa uma grande área da cidade de Porto Alegre/RS e região metropolitana. Na região onde foi amostrado, encontrase hoje uma estrutura de contenção em solo grampeado. Rupturas durante a escavação ocasionaram a necessidade de redimensionamento da estrutura, o que na época foi realizado através de retro-análises de rupturas induzidas. Na ocasião a empresa responsável pela execução da obra retirou blocos indeformados de campo, para que posteriormente fossem determinadas as propriedades geomecânicas deste solo residual. O programa experimental desta dissertação envolveu: (a) ensaios de caracterização; (b) caracterização mineralógica através de difratometria de Raio-X, microscopia ótica e microscopia eletrônica;(c) determinação de parâmetros de resistência ao cisalhamento através de ensaios de cisalhamento direto e (d) determinação de parâmetros de resistência ao cisalhamento residual através de ensaios ring shear. Através dos ensaios de cisalhamento direto foi verificado que o intemperismo no local praticamente não apresenta influência nos parâmetros de resistência ao cisalhamento deste solo, pois ambas as profundidades de amostragem mantém a estrutura da rocha de origem. A resistência ao cisalhamento deste material é em grande parte comandada pela sua micro-estrutura, e principalmente pelo bandamento micáceo Em ambas profundidades foi verificada anisotropia de resistência ao cisalhamento, através de ensaios com a orientação de planos de xistosidade paralela e perpendicular à superfície de ruptura imposta pelo ensaio. Este comportamento demonstra a influência que a macro-estrutura herdada da rocha mãe tem sobre a resistência deste material. Os ensaios ring shear realizados neste material apresentaram ângulos de atrito interno residual baixos em relação ao que se espera de materiais predominantemente granulares como é o caso deste solo. Porém estes valores baixos podem ser atribuídos ao alto teor de mica existente.

Page generated in 0.1178 seconds