Spelling suggestions: "subject:"desistência dda união"" "subject:"desistência daa união""
91 |
Influência do hidróxido de cálcio na resistência de união de cimentos endodônticos resinosos à dentina radicular / Influence of calcium hydroxide in the bond strength of root canal sealers to dentin: push-out testingCarvalho, Ceci Nunes 01 July 2010 (has links)
Avaliou-se a influência do uso do hidróxido de cálcio como medicação intracanal na resistência de união de obturações endodônticas à dentina radicular quando realizadas com o cimento AH Plus ou Epiphany. Raízes palatinas de primeiros molares superiores humanos foram preparadas com sistema rotatório EndoSequence, e divididas em 4 grupos: G1 fatias preenchidas com AH Plus; G2 - fatias preenchidas com Epiphany; G3 - dentes que receberam medicação intracanal com hidróxido de cálcio por 14 dias e posterior preenchimento das fatias com AH Plus; G4 - dentes que receberam medicação intracanal com hidróxido de cálcio por 14 dias e posterior preenchimento das fatias com Epiphany. Para o teste de pushout as raízes foram fixadas, cortadas e delas obtidas secções seriadas das regiões cervical, média e apical. Após a manobra de preenchimento das fatias, essas permaneceram armazenados por 7 dias em câmara a vácuo a 37º C sob condições de umidade ambiental. Decorrido esse período, os dentes foram preparados para o ensaio mecânico. Os corpos-de-prova foram adaptados a um suporte fixado à base da máquina de ensaios mecânicos universal, onde aplicou-se uma carga à velocidade de 0,5 mm/min no sentido ápico-cervical até o completo deslocamento do material obturador. Após a realização dos ensaios, foi feita análise do padrão de fraturas dos corpos de prova utilizando a microscopia eletrônica de varredura. A análise de variância revelou diferença estatisticamente significante entre os grupos (p<0,05). O teste de Tukey identificou que a resistência de união obtida pelos grupos Epiphany e Epiphany + hidróxido de cálcio foi estatisticamente menor do que a dos grupos AH Plus e AH Plus + hidróxido de cálcio; e, a comparação entre grupos mostrou que o grupo AH Plus + hidróxido de cálcio mostrou-se estatisticamente superior ao grupo AH Plus, portanto o hidróxido de cálcio influencia positivamente apenas na adesão do cimento AH Plus. / We evaluated the influence of calcium hydroxide as an intracanal dressing in the bond strength of root canal filling to the root dentin when performed with AH Plus sealer or Epiphany. Palatal roots of maxillary first molars were prepared with rotary system EndoSequence and divided into 4 groups: G1 - slices filled with AH-Plus G2 - slices filled with Epiphany, G3 - teeth that received root canal dressing with calcium hydroxide for 14 days and then filling out the slices with AH-Plus; G4 - teeth that received root canal dressing with calcium hydroxide for 14 days and then filling out the slices with Epiphany. To test push-out the roots were fixed, cut them and obtained serial sections of cervical, middle and apical. After the maneuvers fills the slices, they remain stored for 7 days in a vacuum chamber at 37°C under conditions of environmental humidity. After this period the teeth were prepared for mechanical testing. The samples were adapted to a bracket attached to the base of the testing machine universal where we apply a load at a speed of 0.5 mm/min towards apicocervical to the complete displacement of the filling material. After the testing, analysis was made of the pattern of fractures of the specimens using scanning electron microscopy. Analysis of variance revealed a statistically significant difference between groups (p < 0,05). The Tukey test indicated that the bond strength obtained by the groups Epiphany and Epiphany + Calcium hydroxide was lower than that of groups AH Plus and AH-Plus + Calcium hydroxide; and, the comparison between groups showed that group AH-Plus + Calcium hydroxide was statistically higher than the AH-Plus group, so the Calcium hydroxide has a positive effect only in the adhesion of AH-Plus sealer.
|
92 |
Avaliação dos ensaios de microtração, push-out e pull-out: resistência de união entre pino de fibra e dentina radicular, análise de elementos finitos e microscopia confocal / Evaluation of microtensile, push-out and pull-out bond strength tests in the adhesion of fiber posts to intraradicular dentin. Finite element analysis and confocal microscopyCastellan, Carina Strano 28 June 2007 (has links)
O objetivo deste estudo foi comparar os ensaios de microtração (MI), ?push-out? (PS), ?push-out? modificado (PSM) e ?pull-out? (PL) na habilidade de mensurar a resistência de união (RU) entre pino de fibra e dentina radicular. Para tanto, além dos resultados de cada ensaio mecânico foram analisados fatores como: sensibilidade quanto às diferentes regiões radiculares, quantidade de falhas prematuras (FP), coeficiente de variação (CV), padrão de fratura (PF) pela microscopia confocal de varredura e distribuição das tensões pela análise de elementos finitos (AEF). Foram utilizados 40 dentes anteriores superiores endodonticamente tratados, divididos em quatro grupos de acordo com o tipo de ensaio realizado. Para os ensaios de PS e MI foi feita a cimentação do pino e posteriormente os cortes para a obtenção dos corpos-de-prova (cps). Para os outros ensaios (PSM e PL), a cimentação antecedeu aos cortes tanto das fatias de dentina como dos pinos. O sistema adesivo Scotbond Multi Uso Plus e o cimento Variolink II foram usados para a cimentação do pino de fibra de vidro FRC Postec Plus em todos os casos. Os cps do ensaio de PS foram obtidos pelos cortes seriados da raiz em fatias de 1±0,1mm, para os cps do ensaio de MI estas fatias sofreram ainda a confecção de entalhes laterais diametralmente opostos, que proporcionando um formato final de ampulheta. Para os testes de PL e PSM foram feitos cortes de fatias de dentina de 1±0,1mm e o pino foi dividido em três partes iguais para, então, cada fatia de uma região ser cimentada com o pino correspondente. Os cps do ensaio de PSM tinham 1mm de pino sobressalente para cima e para baixo da fatia de dentina, enquanto que os cps do PL o pino sobressalente estava apenas para cima da dentina. Todos os cps foram submetidos aos testes de RU, à velocidade de 0,5mm/min em máquina de ensaios universais. O PF foi avaliado em um aumento de cem vezes e foi feita uma distribuição de freqüência. Já a AEF obteve modelos tridimensionais de todos os ensaios, e estes foram analisados quanto à tensão de Von Mises. Para os resultados dos testes mecânicos foram feitas análises de variância de cada ensaio variando o fator região, com ou sem as FP, e análise comparando todos os ensaios. O teste Tukey foi feito quando necessário e as FP foram submetidas ao teste estatístico de Fisher. A inclusão ou não destas falhas mostra alteração dos resultados no ensaio de MI, uma vez que possui um maior número delas neste ensaio. O ensaio de PL mostrou as maiores médias de RU, seguido pelo ensaio de PSM, e ambos também tiveram o PF com maior quantidade de fraturas adesivas. O ensaio de PS conseguiu apontar diferença estatística entre as três regiões, mas mostrou a maior freqüência de falhas coesivas, e maior CV. O menor CV foi encontrado para o PSM que também mostrou uma adequada distribuição das tensões. A MI apresentou concentração de tensões nas bordas dos entalhes. Concluiu-se que o tipo de ensaio influencia diretamente nos resultados obtidos. / The aim of this study was to compare microtensile (MI), \"push-out\" (PS), modified \"push-out\" (PSM) and \"pull-out\" (PL) tests in the ability to accurately measure the bond strength of fiber posts luted inside root canals, at different root dentin levels, cervical, middle and apical. The evaluated parameters were: amount of premature failure (PF), coefficient of variation (CV), failure patterns (FP) and the stress distribution by finite elements analysis (FEA). Forty human intact single-rooted and endodontically treated teeth were divided into four groups according to the type test used. For PS and MI specimens, first the post was luted and then the cuts were done, for PSM and PL, first was done the cuts and then fiber post?s pices were luted. Scotbond Multi Use Plus adhesive system and Variolink II cement had been used for luting FRC Postec Plus glass fiber post, in all cases. PS samples were disc shaped of 1±0,1mm. Bond strength between post and dentin was measured in the root slice and the force applied on the center of the specimen. For the Mi test hourglass-shaped samples were obtained by trimming the proximal surfaces of each slice using a diamond bur until it touched the post. For PL and PSM tests cuts of 1±0,1mm of dentine slices were made and the fiber was divided into three parts, and then each slice were luted with a fiber post?s piece. Specimens for PSM had 1mm of post up and down the dentin slice and for PL all of the post was up the dentine slice. All specimens were submitted to a bond strength test at 0.5 mm/minute crosshead speed in a universal testing machine. For FP, each sample was examined under confocal microscopy at 100 times and a frequency distribution was made. For the AEF, three-dimensional models of each tests had been made and analyzed by Von Mises stress. Bond strength data were analyzed by ANOVA and when necessary was used Tukey?s test. For PF data the Fisher test was made. The inclusion of PF, only shows variation on MI, since these test showed the greater number of them. PL provided higher values of bond strength for root dentin and fiber post, followed by PSM. Both of them had also FP with greater amount of adhesive failures. The PS test was able to point statistically differences between root regions, but it showed the highest frequency of cohesive failure, and greater CV. Minor CV was found for the PSM that also showed adequate stress distribution. The MI showed concentration of tensions in the edges of the trimming area. One concluded that the type of test influences directly in the results obtained.
|
93 |
Efeito da atmosfera de sinterização na resistência de união da porcelana com ligas de níquel-cromo e cobalto-cromo / Effect of firing atmosphere on metal ceramic bond strength of nickel-chromium and cobalt-chromiumAlves, Luciana Mara Negrão 11 February 2015 (has links)
O objetivo deste trabalho foi avaliar a influência de dois diferentes ambientes de sinterização (vácuo e argônio) sobre a resistência da união metaloceramica (RUMC) envolvendo diferentes ligas de metais básicos (Co-Cr e Ni-Cr) e uma porcelana odontológica, através do teste de flexão de três pontos, conforme preconizado pela ISO 9693:2012. As ligas estudadas foram Co-Cr: Remanium e Keragen e Ni-Cr: Verabond II e uma liga experimental “SR” . Foram obtidos 80 corpos de prova em forma tiras metálicas medindo 25 X 0,5 X 5 mm. Para esse ensaio, portanto, o número de corpos de prova foi o produto de 4 ligas x 2 condições de atmosfera de sinterização x 10 repetições. A parte metálica de todos os corpos de prova após a fundição foram usinados e jateados com óxido de alumínio (150μm) e a seguir tratados como preconizado pelo fabricante. O corpo cerâmico, com o auxílio de uma matriz, foi confeccionado na área central da tira, 8,0 X 3,0mm, apresentando 1,1mm de espessura, sendo 10 corpos de prova em cada ambiente de sinterização para cada tipo de liga. Os corpos de prova obtidos foram submetidos aos testes de flexão de três pontos na Máquina de Ensaios Mecânicos (EMIC) com velocidade de 1.0mm/min. para determinação da RUMC. Os valores da carga de ruptura obtidos em quilograma-força (Kgf) foram convertidos para Newton (N) e a partir disso foi calculado o valor da RUMC para cada corpo de prova, considerando o coeficiente de elasticidade de cada liga e a espessura exata de cada corpo de prova. Os dados obtidos (MPa) foram submetidos à análise estatística (ANOVA) e Bonferroni. A Análise de Variância indicou diferença estatisticamente significante para os fatores de variação ambiente (P=0,00), liga (P=0,009) e entre as interações ambiente de sinterização e liga (P=0,000). Na sinterização a vácuo as ligas Keragen, SR e Verabond II apresentaram maiores valores de RUMC do que o argônio. Para a liga Remanium, não houve diferença entre a sinterização em argônio e a sinterização a vácuo. Dentre os grupos sinterizados no argônio não houve diferença estatisticamente significante entre as ligas. Entretanto, no vácuo a liga Remanium apresentou menor valor de RUMC do que as demais ligas, que não apresentaram diferença entre si. Os corpos de prova, após os ensaios de flexão, foram submetidos a análise em microscopia optica, MEV e EDS para avaliar e registrar tipo de falha que sofreram. De acordo com a MO, houve predomínio de fraturas mistas. Os corpos de prova de Co-Cr (Remanium e Keragen), independende do ambiente de sinterização, apresentaram uma fina camada de óxido no corpo cerâmico, o que foi comprovado pelo EDS, com maior presença de íons Cr nessas regiões, já os grupos SR e Verabond II, apresentaram maior quantidade de opaco aderido em suas tiras metálicas. A MEV comprovou os achados da MO, onde foi possível encontrar grandes ilhas de material cerâmico nas ligas de Ni-Cr. A sinterização em argônio influenciou negativamente a RUMC dos pares metalocerâmicos confeccionados em Ni-Cr e na liga Keragem / The aim of this study was to evaluate the influence of two different firing atmosphere (vacuum and argon) on the metalceramic bond strength (MCBS) involving different base metal alloys (Co-Cr and Ni-Cr) and a dental porcelain through three-point bending test, as recommended by ISO 9693: 2012. Co-Cr alloys studied were: Remanium and Keragen and Ni-Cr: Verabond II and an experimental alloy \"SR\". 80 specimens were obtained in metallic form strips measuring 25X0.5 X 5.0 mm. For this test, therefore, the number of specimens was the product of 4 x 2 alloy sintering atmosphere conditions x 10 replicates. The metal portion of all specimens were machined after casting and sandblasted with aluminum oxide (100μm) and then treated as recommended by the manufacturer. By using a matrix, the ceramic body was made in the central area of the strip, 8.0 x 3.0 mm, it was made 1.1 mm thickness, 10 specimens in each sintering environment for each type of alloy. The specimens obtained were tested for three-point bending in a universal testing machine with a speed of 1.0mm / min. to determine MCBS. The values of the tensile strength obtained in kilogramforce (kgf) were converted into Newton (N) and from this the value of MCBS for each specimen was calculated, considering the coefficient of elasticity of each league and the exact thickness of each specimen. The data (MPa) were subjected to statistical analysis (ANOVA) and Bonferroni. The analysis of variance indicated statistically significant difference for the environment factors of firing atmosphere (P = 0.00) and alloy (P = 0.009). There was a statistically significant difference in the interaction factors for firing atmosphere x alloy (P = 0.000). In the vacuum Keragen, SR and Verabond II alloys showed higher MCBS than argon. To Remanium, there was no difference between the sintering in argon and vacuum. Among the groups sintered in argon there was no statistically significant difference between the alloys. However, the vacuum Remanium showed the lowest RUMC than other alloys, which showed no difference between them. The specimens after the bending tests, were subjected to analysis in optical microscopy, SEM and EDS to assess and record type of failure they suffered. According to the MO was predominantly mixed fractures. Specimens of Co-Cr (Remanium and Keragen) independende the atmosphere firing, showed a thin oxide layer on the ceramic body, which was confirmed by EDS, with greater presence of Cr in these regions, since the SR groups and Verabond II, presented more opaque stuck in their metal strips. SEM confirmed the findings of MO, where it was possible to find large islands of ceramic material in Ni-Cr alloys. The sintering in argon negatively influenced MCBS metalceramic of pairs made of Ni-Cr alloy and Keragem
|
94 |
Efeito de três diferentes doses de radiação com raios-X na microdureza, morfologia superficial, espectrometria de energia dispersiva de radios-X (EDS) e resistência de união ao esmalte e dentina com dois diferentes sistemas adesivos / The effect of three different doses of radiation with x-rays in the microhardness, superficial morfology, energy dispersive X-ray spectroscopy (EDS) and bond strength of enamel and dentin with two adhesive systemsCunha, Sandra Ribeiro de Barros da 19 January 2015 (has links)
Este estudo teve como objetivo analisar dentina e esmalte irradiados com diferentes doses de radiação ionizante com raios-x (20, 40 e 70Gy), através da microdureza, morfologia superficial, conteúdo mineral e resistência de união com adesivo de condicionamento total de 2 etapas (Adper Single Bond 2) e um novo sistema adesivo, universal, com a técnica auto-condicionante (Universal Single Bond). Oitenta e quatro terceiros molares humanos foram cortados, separados e preparados para cada ensaio. Para os ensaios de microdureza e microcisalhamento as amostras foram incluídas em resina acrílica e polidas. Para a microscopia eletrônica de varredura (MEV) e espectrometria de energia dispersiva de raios-x (EDS), as amostras foram fixadas em solução de glutaraldeído 3%, lavadas em solução de cacodilato 0,1M e desidratadas em álcool etílico crescente. A microdureza (n=30) foi realizada pré e pós-radioterapia, com força de 50gf em esmalte cervical, médio e oclusal e 25gf em dentina profunda, média e rasa, por 30s. As amostras para o microcisalhamento foram divididas em 4 grupos (n=20) e 2 subgrupos (n=10) conforme o sistema adesivo. Foram construídos 3 corpos de prova cilíndricos com 1mm de diâmetro e altura em cada amostra. O teste de microcisalhamento foi realizado em máquina de ensaio universal com velocidade de 1mm/min. Os resultados indicam perda de propriedade de microdureza apenas em esmalte cervical em todas as três doses (20Gy pré-radioterapia: 298,04±11,80 e pós-radioterapia: 294,36±16,68; 40Gy pré-radioterapia: 285±19,45 e pósradioterapia: 275,3±36; 70Gy pré-radioterapia: 291,98±16,51 e pós-radioterapia: 283,68 ± 21,64) e em dentina em todas as profundidades (profunda: 20Gy préradioterapia: 57,79±1,96; pós-radioterapia: 55,37±1,30; 40Gy pré-radioterapia: 57,31±1,76; pós-radioterapia: 55,83±1,63; 70Gy não apresentou alterações; média: 20Gy pré-radioterapia: 58,05±1,79; pós-radioterapia: 55,36±1,20; 40Gy préradioterapia: 57,87± 2,04; pós-radioterapia: 55,65 ± 2,48; 70Gy não apresentou alterações; rasa: 20Gy pré-radioterapia: 56,60±12,17; pós-radioterapia: 55,18±2,57; 40Gy pré-radioterapia: 57,36±2,78; pós-radioterapia: 55,18± 2,57; 70Gy préradioterapia: 55,08±1,94; pós-radioterapia: 54,72±2,57). O teste de microcisalhamento não apresentou diferença significativa entre grupo controle e as 3 doses, tanto para esmalte (p=0,325) como para dentina (p=0,719), apresentando o adesivo Universal Single Bond, em dentina, a resistência de união mais satisfatória. A análise de padrão de fratura para dentina, indicou um maior número de rupturas coesivas em dentina na dose 70Gy quando comparada ao grupo controle. Em esmalte prevaleceram as fraturas do tipo adesivas. As eletromicrografias apresentaram alterações apenas em esmalte na dose 70Gy, com prismas de esmalte mais curtos e arredondados. O EDS mostrou que o conteúdo mineral permaneceu intacto em ambos substratos. Dentro das limitações de um estudo in vitro, conclui-se que a radiação ionizante apresenta maior interação preferencialmente em dentina, no entanto, o EDS mostra não haver modificação no conteúdo mineral em ambos substratos. Existe uma diminuição da microdureza em dentina, porém as alterações não são suficientes para interferir na resistência de união dos substratos irradiados, que mostraram resultados mais satisfatórios com o sistemas adesivos universal, utilizando-se a técnica auto-condicionante. / The aim of this study was to evaluate the effects of different doses (20Gy, 40Gy and 70Gy) of ionizing radiation with x-rays in the microhardness, superficial morphology, mineral content and bonding effectiveness with a 2 steps all-etch adhesive (Adper Single Bond 2) and the new generation of adhesive, the universal adhesive system, (Universal Single Bond), using the self-etch technique. Eighty-four third molars were cutted, separed and prepared for each assay. For the microshear-bond and microhardness the samples were included in acrylic resin and then polished. For the scanning electron miscroscopy (SEM) and energy dispersive x-ray spectroscopy (EDS), the samples were fixated in a 3% glutaraldehyde solution, washed in 0,1M cacodylate solution and dehydrated in increscent concentrations of ethyl alcohol. The microhardness (n=30) was held pre and post radiotherapy with 50gf on cervical, middle and occlusal enamel and 25kg on superficial, middle and deep dentin, both cases with 30s. The microshear-bond was divided in 4 groups (n=20) and 2 subgroups (n=10) according to the adhesive system. Three cylinders were built with 1mm in diameter and heigh in every sample. The assay were accomplished at an universal testing machine with 1mm/min. Results indicate loss of microhardness properties only in cervical enamel at all 3 doses (20Gy pre-radiotheraphy: 298,04 ± 11,80 and post-radiotherapy: 294,36 ± 16,68; 40Gy pre-radiotherapy: 285 ± 19,45 and post-radiotherapy: 275,3 ± 36; 70Gy pre-radiotherapy: 291,98 ± 16,51 and post-radiotherapy: 283,68 ± 21,64) and in all dentin depths (deep: 20Gy preradiotherapy: 57,79 ± 1,96; post-radiotherapy: 55,37 ± 1,30; 40Gy pre-radiotherapy: 57,31 ± 1,76; post-radiotherapy: 55,83 ± 1,63; 70Gy showed no alteration; Middle: 20Gy pre-radiotherapy: 58,05 ± 1,79; post-radiotherapy: 55,36 ± 1,20; 40Gy preradiotherapy: 57,87 ± 2,04; post-radiothetrapy: 55,65 ± 2,48; 70Gy showed no alteration; Superficial: 20Gy pre-radioterapia: 56,60 ± 12,17; post-radiotrapia: 55,18 ± 2,57; 40Gy pre-radiotherapy: 57,36 ± 2,78; post-radiotherapy: 55,18 ± 2,57; 70Gy pre-radiotherapy: 55,08 ± 1,94; post-radiotherapy: 54,72 ± 2,57). The microshearbond test did not show significant difference between the control group and the 3 doses, both enamel (p=0.325) and dentin (p=0.719), showing better bonding with Universal Single Bond adhesive in dentin. The fracture pattern analysis indicated a larger number of cohesive failure in dentine with the 70Gy dose when compared with control group. The micrographs showed changes only on enamel at 70Gy dose, with shorter and rounder prisms. EDS test indicated no changes in mineral content for both substrates. Knowing the limitations of an in vitro study, it were concluded that ionizing radiation shows deleterious effects preferentially in dentin, probably due to it\'s high organic content, since EDS showed no modifications both enamel and dentin. There is a reduction in microhardness on dentin, but the changes are not enough to interfere at bonding properties of irradiated substrates, showing better results when used the universal adhesive with the self-etch techniques.
|
95 |
Estudo longitudinal da resistência e qualidade de união de diferentes sistemas adesivos à dentina irradiada com laser de femtossegundos / Long term evaluation of bond strength and quality of the interface of different adhesive systems to femtosecond laser irradiated dentinMoretto, Simone Gonçalves 17 December 2012 (has links)
Recentemente, os lasers de pulsos ultracurtos têm sido avaliados para o preparo dos tecidos duros dentais devido à sua habilidade de reduzir os efeitos térmicos resultantes da irradiação. O objetivo deste estudo foi avaliar a efetividade de união de 3 sistemas adesivos à dentina preparada com o laser de femtossegundos (10-15 s). Para isso, 60 terceiros molares foram preparados com o laser de femtossegundos (1.450 nm; 0,3W; 100.000Hz) ou ponta diamantada, divididos em 3 subgrupos (n=10) restaurados utilizando o adesivo condicione e lave de 3 passos Optibond FL (OFL; Kerr), o autocondicionante de 2 passos Clearfil SE (CSE; Kuraray) ou o autocondicionante de 1 passo G-aenial Bond (GAB; GC). Após 1 semana de armazenamento em água, os dentes foram seccionados (1,0x1,0 mm) e testados imediatamente e após 6 meses de armazenamento. Vinte e quatro amostras adicionais foram preparadas com o laser ou ponta diamantanda conforme descrito acima. Seis amostras foram seccionadas em espécimes menores e aleatoriamente preparados para observação das características morfológicas da superfície (n=3) e subsuperfície (n=3) em Microscópio Eletrônico de Varredura (MEV) (n=3) e Microscopia Eletrônica de Transmissão (MET) (n=3). As outras 18 amostras foram restauradas com os sistemas adesivos supramencionados, seccionados em espécimes menores e distribuídos para avaliação da interface adesiva em MEV (n=3) e padrão de nanoinfiltração após 1 semana (n=2) e 6 meses (n=2) em MET. O modelo linear de efeitos mistos (=0,05) revelou um efeito significante dos fatores adesivo, armazenagem e a interação preparo x armazenagem na resistência de união. Todos os adesivos apresentaram uma redução significante da resistência de união após 6 meses de armazenamento (p<0,0001) para ambos os tipos de preparo. Com relação ao sistema adesivo, a única diferença verificada foi o maior valor de resistência de união do GAB quando aplicado sobre as superfícies irradiadas (56,71±10,72 MPa) quando comparadas com as preparadas com ponta diamantada (43,14±14,93 MPa) após 1 semana de armazenamento. A análise de fratura revelou fraturas mistas, adesivas e coesivas em dentina para ambos os métodos de preparo com um discreto aumento do número de fraturas mistas após 6 meses de armazenamento exceto para o GAB, que apresentou principalmente fraturas adesivas e mistas. A análise em MEV revelou uma fina camada de debris sobre a superfície da dentina irradiada e a hibridização com todos os sistemas adesivos resultou num íntimo contado da interface adesiva com o substrato. A análise em MET da subsuperfície irradiada revelou fibrilas colágenas preservadas. A análise da interface adesiva revelou um aumento dos depósitos de prata na camada híbrida para todos os adesivos, após 6 meses de armazenamento, independentemente do tipo de preparo. Apenas o GAB apresentou maiores depósitos de prata após 1 semana de armazenamento para as superfícies preparadas com ponta diamantada. A irradiação com o laser de femtossegundos não reduziu a receptividade da dentina aos sistemas adesivos, resultando em valores de resistência de união similares aos obtidos com a ponta diamantada; além de uma ótima interação do substrato com os sistemas adesivos e deposições de prata similares àquelas obtidas com a ponta diamantada. / Recently, the applicability of ultrashort pulsed lasers has been studied for dental hard-tissue irradiation because of its reduced residual thermal damage. The aim of this study was to determine the bonding effectiveness of 3 contemporary adhesive systems to dentin prepared by femtosecond (10-15 sec) laser-irradiation. For this, 60 third molars were prepared either by the femtosecond laser (1450 nm; 0.3W; 100,000Hz) or by bur, randomly divided into 3 subgroups (n=10) and restored with a composite using either the 3-step etch-and-rinse adhesive Optibond FL (OFL; Kerr), the 2-step self-etch adhesive Clearfil SE (CSE; Kuraray) or the 1-step self-etch adhesive G-aenial Bond (GAB; GC). After 1-week water storage, the teeth were sectioned (1.0x1.0 mm) and half of the specimens were tested until failure using a micro-tensile bond-strength (TBS) approach. The other half was stored in water and tested after 6 months. Twenty-four additional dentin samples were exposed to the diamond bur and the laser, following the same abovementioned parameters. Three samples of each treatment were sectioned in smaller specimens in order to be characterized for surface (n=3) and cross-sectional morphological analysis using Scanning Electron Microscopy (SEM) (n=3) and Transmission Electron Microscopy (TEM) (n=3). The other eighteen samples were hybridized with the abovementioned adhesive systems, sectioned in smaller samples and distributed for evaluation of the interface under SEM (n=3) and nanoleakage distribution for 1 week (n=2) and 6 months (n=2) under TEM. Linear mixed effect model (=0.05) revealed a significant effect of the factors adhesive, storage and the interaction of preparation x storage on the TBS. All adhesives presented a significant reduction of the bond strength after 6-month storage (p<0.0001) for both preparation methods. Regarding the adhesive system, the only difference found was a significantly higher TBS of GAB to laser-irradiated (56.71±10.72 MPa) than to bur-cut dentin (43.14±14.93 MPa) after 1-week water storage. Fracture analysis showed mixed, adhesive and cohesive failures in dentin similarly for both preparation methods with a slightly increase of the mixed failures after 6-months water storage for OFL and CSE, but not for GAB that presented mainly adhesive and mixed failures. SEM disclosed a thin layer of debris on the laser-irradiated dentin surface and the hybridization with all adhesive systems resulted in a very tight interface. TEM analysis of the irradiated subsurface revealed collagen fibrils preserved and for the nanoleakage evaluation an increase of silver deposits at hybrid layer for all adhesives testes after 6-months water storage, irrespective of the preparation methods. Only the GAB presented great silver deposits even after 1-week water storage for the bur-cut preparation method. Femtosecond laser irradiation did not reduce the bonding receptiveness of dentin resulting in similar values obtained with the preparation by bur. Additionally it led to a great interaction with different adhesive systems and silver deposits comparable to those obtained with the bur-cut preparation method.
|
96 |
Influência de diferentes protocolos de irradiação do laser de Er:YAG na morfologia dentinária, na formação da camada híbrida e na resistência adesiva / Er:YAG laser protocols influence on dentin morphology, hybrid layer formation and bond strengthTrevelin, Lívia Tosi 05 December 2018 (has links)
Este estudo longitudinal in vitro avaliou a ação de diferentes larguras de pulso empregadas no protocolo de preparo cavitário e pré-tratamento dentinário com o laser de Er:YAG sobre a ultramorfologia da dentina, a micromorfologia da interface adesiva e resistência de união. Cento e doze molares humanos foram seccionados, obtendo-se uma dentina de profundidade média e, em seguida, foram distribuídos de acordo com os protocolos de irradiação da superfície dentinária: preparo cavitário (200 mJ/20 Hz) e pré-tratamento (80 mJ/2 Hz). Os fatores em estudo foram a largura de pulso (50 ?s, 300 ?s e 600 ?s) e tempo de armazenamento (24 h e 1 ano). Para cada condição de tratamento de superfície (protocolo de irradiação), foi considerado um grupo controle, sem irradiação. Os espécimes foram avaliados por diferentes métodos, a saber: análise da ultramorfologia por microscopia eletrônica de transmissão (MET) (n=3); avaliação da micromorfologia da interface adesiva por meio de microscopia confocal (n=3); avaliação da matriz orgânica e fibrilas colágenas por meio da Segunda Gerão Harmônica (n=3). Foram realizadas também a avaliação da resistência de união por ensaio de microcisalhamento nos espécimes submetidos ao protocolo de pré-tratamento da dentina (?SBS) (n=12) e por ensaio de microtração (?TBS) (n=11) nos espécimes submetidos ao protocolo de irradiação de preparo cavitário. Os experimentos de microscopia confocal e resistência de união foram realizados utilizando um sistema adesivo autocondicionante (Scotchbond Universal, 3M ESPE, EUA) em conjunto a uma resina composta (Z350 XT, 3M ESPE, EUA). Estes espécimes foram analisados após 24 hs e 1 ano de armazenamento em saliva artificial. Os dados quantitativos obtidos nos ensaios de resistência de união foram analisados por meio do teste de ANOVA (dois fatores) e do teste de comparações múltiplas de Tukey (? = 0,05). Os dados qualitativos foram comparados e descritos detalhadamente. Os resultados de resistência de união imediato dos grupos irradiados mostraram valores mais baixos quando comparados ao grupo controleo, independente do protocolo empregado assim como da largura de pulso utilizada. Os baixos valores expressos nos ensaios de resistência de união podem ser justificados pelas alterações na ultraestrutura da dentina irradiada com o laser de Er:YAG, que denotam uma clara alteração da matriz orgânica com desnaturação das fibrilas colágenas, como demostrada pelas imagens de SGH e MET. Desta forma, as alterações nas estruturas orgânicas da dentina prejudicaram a formação da uma camada híbrida consistente que levou à degradação das interfaces adesivas e consequente redução dos valores de resistência de união em 24 h. Todos os espécimes ensaiados no teste de microtração apresentaram redução significativa após 1 ano de armazenamento em saliva artificial, independente do tratamento realizado. Entretanto, os espécimes ensaiados no teste de microcisalhamento não apresentaram redução significativa após o mesmo período de armazenamento (1-ano). Embora o protocolo de pré-tratamento tenha alterado os componentes orgânicos da dentina, essas alterações não foram suficientes para reduzir os valores de resistência de união após 1 ano de armazenamento. Sendo assim, o emprego do laser de Er:YAG, em ambos os protocolos investigados, resultaram em modificações permanentes nos componentes orgânicos da dentina, que infleuncirama negativamente os valores de resistência de união a esse substrato. / This longitudinal in vitro study evaluated the action of different pulse widths employed in the protocol of cavity preparation and pre-treatment with the Er: YAG laser on the ultramorphology of dentin, the micromorphology of the adhesive interface and bond strength. One hundred and twelve human molars were sectioned to obtain a medium depth dentin and then distributed according to the dentin surface irradiation protocols: cavity preparation (200 mJ / 20 Hz) and pretreatment (80 mJ / 2 Hz). The factors under study were the pulse width (50 ?s, 300 ?s and 600 ?s) and storage time (24 h and 1 year). For each surface treatment condition (irradiation protocol), it was considered a control group, without irradiation. The specimens were evaluated by different methods, such as: ultramorphology analysis by transmission electron microscopy (MET) (n = 3); analysis of the adhesive-interfaces by confocal microscopy (n = 3); evaluation of the organic matrix and collagen fibrils by Second Harmonic Generation (n = 3). The bond strength was evaluated by micro-shear test in the specimens submitted to the pre-treatment protocol (?SBS) (n = 12) and by microtensile test (?TBS) (n = 11) in specimens submitted to cavity preparation`s protocol. Confocal microscopy and bond strength experiments were performed using a self-etching adhesive system (Scotchbond Universal, 3M ESPE, USA) together with a composite resin (Z350 XT, 3M ESPE, USA). These specimens were analyzed after 24 h and 1 year of storage in artificial saliva. The quantitative data obtained in the bond strength tests were analyzed using the ANOVA test (two factors) and Tukey\'s multiple comparison test (? = 0.05). Qualitative data were compared and described in detail. The results of immediate bond strength of the irradiated groups showed lower values when compared to the control group, regardless of the protocol used as well as the pulse width used. The low values expressed in the bond strength tests can be justified by the changes in the ultrastructure of the dentin irradiated with the Er: YAG laser, which denote a clear alteration of the organic matrix and collagen fibrils, as observed in SGH and MET images. In this way, the changes in the organic structures of dentin impaired the formation of a consistent hybrid layer that lead to the degradation of the adhesive-interfaces and consequent drop of bond strength values at 24 h. All specimens tested in the microtensile test showed a significant reduction of bond strength after 1 year of saliva storage, regardless treatment performed. However, the specimens tested in the micro-shear test did not show significant reduction of bond strength after the same storage period (1-year). Although the pre-treatment protocol altered the organic components of dentin, these changes were not enough to reduce bond strength values after 1 year of storage. Thus, the use of the Er: YAG laser, in both protocols investigated, resulted in permanent modifications in the organic components of the dentin, which negatively influences the bond strength values to this substrate.
|
97 |
Análise in vitro da resistência de união da resina composta contendo biomaterial S-PRG(Ionômero de Vidro com Superfície Pré-Ativada) à dentina erodida / In vitro analysis of the bond strength of composite resin containing biomaterial S-PRG(Surface Pre-Reacted Glass) to eroded dentinLourenço, Alessandra Sanchez Coelho 02 June 2017 (has links)
O tratamento da erosão dental transformou-se no novo desafio do século XXI e a restauração direta com resina composta é uma das opções de tratamento para lesões severas, em que há comprometimento estético e funcional. Dentro desse contexto, novos materiais restauradores têm sido avaliados, como materiais contendo flúor em sua composição. Desta forma, o presente estudo teve como por objetivo avaliar in vitro a resistência de união da resina composta contendo ou não biomaterial S-PRG (Ionômero de Vidro com Superfície Pré-Ativada) à dentina erodida. A dentina oclusal planificada de 30 molares humanos (n=15) teve metade de sua face protegida com verniz ácido resistente (dentina hígida - grupo controle), enquanto na outra metade foi produzida uma lesão de erosão através da ciclagem em ácido cítrico 0,05 M (pH 2,3, 10 minutos, 6x/dia) e solução supersaturada (pH 7,0, 60 minutos entre os ataques ácidos). Em cada substrato, foram testados dois sistemas adesivos (um autocondicionante e outro com condicionamento prévio) e duas resinas compostas - uma com nanopartículas (Z350-3M/ESPE) e uma que contém biomaterial S-PRG(Ionômero de Vidro com Superfície Pré-Ativada) em sua composição (Beautifil II -Shofu Inc.). Foram, então, confeccionados cilindros de resina composta, os quais foram submetidos à avaliação da Resistência de União através do ensaio de microtração, após armazenamento em água por 24 horas. A análise do padrão de fratura foi realizada em microscópio ótico (40x). Os valores obtidos de resistência de união (MPa) foram submetidos aos testes de ANOVA (dois fatores) e de comparações múltiplas de Tukey (p<0,05). De acordo com os resultados, não houve diferença estatisticamente significativa entre a interação substrato e materiais restauradores (p=0.711). No entanto, houve diferença entre os substratos (p<0,001) e os materiais restauradores (p=0,002) avaliados. Quanto à resistência de união, os valores obtidos foram: G1 (47,5 ± 12,2 MPa), G2 (34,1 ± 15,8 MPa), G3(31,0 ± 8,3 MPa) e G4 (15,5 ± 13,6 MPa). Os resultados, revelaram uma diferença estatisticamente significante nos substratos avaliados e materiais restauradores. Dentro dos limites do presente estudo, conclui-se que a resistência de união no substrato erodido é inferior ao substrato hígido e que o sistema adesivo autocondicionante contendo biomaterial S-PRG(Ionômero de Vidro com Superfície Pré-Ativada) resulta em menor resistência de união da resina composta à dentina hígida ou erodida. / The treatment of dental erosion has become the new challenge of the 21st century and direct restoration with composite resin is one of the treatment options for severe injuries, in which there is aesthetic and functional impairment. Within this context, new restorative materials have been introduced containing fluoride in their composition. In this way, the objective of the present in vitro study was to evaluate the bond strength of composite resin containing or not biomaterial (S-PRG- Surface Pre-Reacted Glass ) to the eroded dentine. Planned occlusal dentin of 30 human molars (n = 15) had half of its surface protected with acid resistant varnish (sound dentin - control group), while on the other half an erosion lesion was produced by cycling in 0.05 citric acid M (pH 2.3, 10 minutes, 6x/day) and supersaturated solution (pH 7.0, 60 minutes between acid attacks). On both eroded and non-eroded substrates, two adhesive systems (one self-etching and one with pre-conditioning) and two composite resins (one with nanoparticles (Z350-3M / ESPE) and one containing biomaterial S-PRG(Glass Ionomer with Pre-Activated Surface) (Beautifil II-Shofu Inc.)) were tested. Then, composite resin cylinders were built and, after storage in water for 24 hours, were submitted to shear bond strength evaluation under microtensile bond test. The analysis of the fracture pattern was performed under an optical microscope (40x). The obtained values of shear bond strength (MPa) were submitted to ANOVA (two factors) and Tukey multiple comparisons tests (p<0.05). According to the results, there was no statistically significant difference between substrate interaction and restorative materials (p = 0.711). However, there was a difference between the substrates (p <0.001) and the restorative materials (p = 0.002) evaluated. The values obtained were G1 (47.5 ± 12.2 MPa), G2 (34.1 ± 15.8 MPa), G3 (31.0 ± 8.3 MPa) and G4 (15 , 5 ± 13.6 MPa), with a statistically significant difference in the evaluated substrates and restorative materials. The results, revealed a statistically significant difference in the evaluated substrates and restorative materials. According to the limits of the present study, it was concluded that the bond strength in the eroded substrate is inferior to the sound substrate and that the self-etching adhesive system containing S-PRG(Surface Pre-Reacted Glass) biomaterial results in lower bond strength of the composite resin to the sound or eroded dentin.
|
98 |
Efeito do ambiente de sinterização na resistência de união de cerâmicas a ligas de níquel-cromo, cobalto-cromo e titânio comercialmente puro / Effect of firing atmosphere on metal ceramic bond strength of nickelchromium, cobalt-chromium and commercially pure titaniumRocha, Milena Teixeira da 23 November 2012 (has links)
O objetivo deste trabalho foi avaliar o efeito do ambiente de sinterização vácuo e argônio na resistência de união (RUMC) de cerâmicas às ligas de Ni-Cr (Fit Cast SB), Co-Cr (Star Loy C) e titânio comercialmente puro (Tritan). A partir de uma matriz de teflon, foram obtidos 60 padrões de resina/cera em forma de cilindro, com 8 mm de comprimento e 5 mm de diâmetro. Os padrões foram incluídos e os anéis foram levados ao forno e submetidos a ciclos térmicos para a expansão do revestimento. Em seguida, os anéis para fundição em Ni-Cr e Co-Cr foram levados à máquina de fundição por indução eletrônica. Os anéis referentes ao titânio foram levados à máquina de fundição por arco voltaico. Após resfriamento dos anéis, as fundições foram desincluídas e jateadas com óxido de alumínio (100 μm). Depois de recortados dos canais de alimentação, os cilindros metálicos foram preparados para aplicação da cerâmica. Em seguida, foi realizada a aplicação e sinterização da cerâmica à vácuo ou em argônio. Para as ligas alternativas, foi utilizada a cerâmica IPS Classic V e para o titânio, a Triceram. Na sequência, os cilindros compostos pelo metal e disco cerâmico (5 mm de diâmetro e 2 mm de espessura) (n=10) foram submetidos aos ensaios de RUMC por cisalhamento na máquina de ensaios universais com célula de carga de 500 Kg e velocidade do travessão móvel de 0,5 mm/min. Após os ensaios, foram realizadas análises das fraturas por meio de microscopia óptica (MO) (15X) e microscopia eletrônica de varredura (MEV). Os dados de RUMC (MPa) obtidos foram analisados estatisticamente pelos testes ANOVA e Tukey (α=0,05). Os resultados demonstraram que a sinterização à vácuo propiciou obtenção de maiores valores (MPa) de RUMC (76,58) que a sinterização em argônio (51,31). Quanto às ligas avaliadas, as de Ni-Cr e Co-Cr apresentaram maiores valores de RUMC (71,32 e 71,28, respectivamente) que o titânio cp (49,23); sendo que entre elas não houve diferença estatística. Não houve interação entre os fatores avaliados. De acordo com a MO, houve predomínio de fraturas mistas. Segundo a MEV, os espécimes de Ni-Cr e titânio sinterizados a vácuo apresentaram maior rugosidade de superfície do que os sinterizados em argônio. Para a liga de Co-Cr não houve diferença na topografia de superfície. A sinterização em argônio influenciou negativamente a RUMC dos pares metalocerâmicos analisados. / The aim of this study was to evaluate the effect of firing atmospheres: vacuum and argon on the bond strength of ceramic to Ni-Cr (Fit Cast SB), Co-Cr (Star Loy C) and commercially pure titanium (Tritan) alloys. 60 wax/acrylic resin cylinder patterns (8 mm high and 5 mm in diameter) were prepared on a plastic custom mold for metalceramic bond strength (MCBS) test. The patterns were invested in phosphated investment and manipulated on vacuum. The rings were placed in a furnace to burn out patterns and thermally expand the molds. Then, the rings of Ni-Cr and Co-Cr were placed in an electronic machine to cast. The rings related to titanium were positioned in the casting machine with a voltaic arc. After the rings have cooled, the castings were divested manually and abraded with aluminum oxide particles (100 μm). Then, the cylinders were prepared for applying of the ceramic veneering disks. The ceramic was applied and fired in vacuum and argon atmospheres. IPS-Classic ceramic was used for alternative alloys and for titanium, Triceram ceramic. Then, the cylinders composed of metal and ceramic disk (5 mm diameter and 2 mm height) (n=10) were submitted to metal-ceramic bond strength (MCBS) shear tests on an universal testing machine with load cell of 500 Kg at a crosshead speed of 0.5 mm/min. After the tests, there were made fracture analysis by optic microscopy (OM) and scanning electron microscopy (SEM). The MCBS data (MPa) were statistically analyzed by the ANOVA and Tukey test (α=0.05). The results indicated that the vacuum firing (76.58) promoted higher MCBS values than argon firing (51.31). Among the metals, Ni-Cr and Co-Cr alloys presented higher MCBS (71.32 e 71.28, respectively) than titanium (49.23); between two base alloys there was no statistical difference. There was no interaction between the evaluated factors. According to MO analysis, there was predominance of mixed fractures. According SEM, the Ni-Cr and titanium specimens submitted to vacuum presented higher surface roughness than the specimens submitted to argon. For Co-Cr, there was no difference of surface topography. The argon firing influenced negatively the MCBS of metal-ceramic evaluated pairs.
|
99 |
AVALIAÇÃO DE PROPRIEDADES DE UNIÃO DE ADESIVOS UNIVERSAIS AO CANAL RADICULAR PREPARADO COM DIFERENTES INSTRUMENTOS ROTATÓRIOS / Evaluation of bonding properties of universal adhesives to root canal prepared with different rotary instrumentsBakaus, Thaís Emanuelle 16 February 2016 (has links)
Made available in DSpace on 2017-07-24T19:22:01Z (GMT). No. of bitstreams: 1
Thais Bakaus.pdf: 1611331 bytes, checksum: 4d80c0ed64cbca5d883bbdad39b16c0d (MD5)
Previous issue date: 2016-02-16 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The objective of this study was to evaluate the influence of a rotating device used to prepare the root canal in the adhesion of glass fiber posts and evaluate different bonding strategies using universal adhesive systems. One hundred human premolars were used, which had their crowns removed and their roots endodontically treated. Initially, the roots were divided into four groups, according to a combination of the factors: a rotating device used to prepare the root canal - carbide bur (CB) and diamond bur (DB) and cementation system (universal adhesive system associated with its respective resin cement - Single Bond Universal / RelyX ARC (SB) and Prime&Bond elect / Enforce (PB). They were then divided into subgroups according to the bonding strategy: Self-etch (SE) or Etch-and-rise (E&R). Eight teeth per group were evaluated in bond strength (BS) by the push-out test and 4 in nanoleakage teeth (NL) by scanning electron microscopy (SEM), and the roots for these tests were transversely sectioned in 6 slices. The data of BS and NI for each cementation system were subjected to 2-way ANOVA and Tukey (α = 0.05). For BS, only the major factors were significant (p <0.05), and for both cementation systems, the highest BS values were observed for the preparation with DB compared to the CB and SE adhesion strategy compared with E&R. Likewise, the interaction was not significant for NL (p> 0.05). For the cementation system PB, the lowest values were observed for groups using DB compared to the CB and SE adhesion strategy compared to E&R. For the SB cementation system, only the rotating device main factor was significant (p = 0.01), whereas the DB resulted in lower average nanoleakage compared to the CB. It can be concluded that to improve the adhesion of glass fiber posts to root canal, diamond bur should be used to prepare the root canal; and, in general, universal adhesive systems must be used in self-etch mode to obtain satisfactory results on intracanal adhesion. / Avaliou-se a influência do instrumento rotatório utilizado para preparo do conduto radicular na adesão de pinos de fibra de vidro e diferentes estratégias de adesão utilizando sistemas adesivos universais. Foram utilizados 100 pré-molares inferiores humanos, os quais tiveram suas coroas removidas e suas raízes tratadas endodonticamente. Inicialmente, as raízes foram divididas em quatro grupos, de acordo com a combinação dos seguintes fatores: instrumento rotatório utilizado para preparo do conduto radicular - broca carbide (BC) e ponta diamantada (PD) e sistema de cimentação (sistema adesivo universal associado com seu respectivo cimento resinoso) - Single Bond Universal/RelyX ARC (SB) e Prime&Bond elect/Enforce (PB). Foram divididos então em subgrupos de acordo com a estratégia de adesão: Self-etch (SE) ou Etch-and-rinse (E&R). Oito dentes por grupo foram avaliados em resistência de união (RU) pelo teste de push-out e 4 dentes em nanoinfiltração (NI) por microscopia eletrônica de varredura (MEV), sendo que para esses testes as raízes foram seccionadas transversalmente em 6 fatias. Os dados de RU e NI para cada sistema de cimentação foram submetidos à ANOVA 2 fatores e Tukey (α=0,05). Para RU, apenas os fatores principais foram significativos (p < 0,05), sendo que para ambos os sistemas de cimentação maiores valores de RU foram observados para o preparo radicular com PD em comparação com a BC e para a estratégia de adesão SE comparada a E&R. Da mesma maneira, a interação não foi significativa para NI (p > 0,05). Para o sistema de cimentação PB menores valores foram observados para os grupos que utilizaram PD em comparação com a BC e para a estratégia de adesão SE em comparação com a E&R. Para o sistema de cimentação SB, apenas o fator principal instrumento rotatório foi significante (p = 0,01), sendo que a PD resultou em menores médias de nanoinfiltração em comparação com a BC. Pode-se concluir que para melhorar a adesão de pinos de fibra de vidro ao canal radicular pontas diamantadas devem ser utilizadas para o preparo do conduto radicular; e, de maneira geral, os sistemas adesivos universais devem ser utilizados na maneira self-etch para obterem resultados satisfatórios de adesão intracanal.
|
100 |
Influência do operador e agente cimentante na resistência de união de pinos de fibra de vidro à dentina radicular / Influence of the operator skill and luting agent on the bond strength of glass fiber post to radicular dentin.Gomes, Giovana Mongruel 22 February 2010 (has links)
Made available in DSpace on 2017-07-24T19:22:11Z (GMT). No. of bitstreams: 1
Giovana Mongruel Gomes.pdf: 1282438 bytes, checksum: 3923d5e2e659866f5b3a3e842b6cceb4 (MD5)
Previous issue date: 2010-02-22 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The aim of this study was to evaluate the influence of the operator skill and resin cement system on the bond strength (BS) of glass fiber post to radicular dentin in
different root thirds. Forty-eight extracted human upper central incisors were sectioned transversally immediately below the cement-enamel junction and the roots were treated endodontically. After one week, standardized post space cavities were prepared, and the roots randomly divided into two groups (n=24), according to the operator skill: professional (CD) vs academic (AC). The roots were then subdivided into three subgroups (n=8) according to the cementation system: CD1 and AC1
(Adper Scotchbond Multi-Purpose [SBMP] + RelyX ARC [ARC]), CD2 and AC2 (Adper Single Bond 2 [SB] + ARC) and CD3 and AC3 (RelyX U100 [U100]). The
glass fiber post (Tenax Fiber Trans Esthetic Post System) were cemented following the manufacturer’s instructions of each cementation system. After water storage at
37o C for one week, each root was sectioned transversely into six 1-mm thick discs and the coronal (TC), middle (TM) and apical (TA) thirds of the root canal identified. A push-out test was carried out at a crosshead speed of 0,5 mm/min. The data were
statistically analyzed by ANOVA and post-hoc Tukey's tests (p=0.05). The mean bond strengths (BS) values (MPa) and standard deviations (SD) of each subgroup
were: CD1: 12.83±7.26; CD2: 11.46±4.22; CD3: 14.27±6.59; AC1: 9.70±4.37; AC2: 8.02±5.25 and AC3: 13.40±4.93. The BS of the CD and AC groups were 12.85±6.18 and 10.37±5.30, respectively. In regard to the root thirds, the means and SD were: TC: 14.46±5.55; TM: 10.04±5.07 and TA: 10.35±6.01. The mean and SD for the cementation systems were: SBMP + ARC: 11.27±6.13; SB + ARC: 9.74±5.03 and
U100: 13.83±5.77. The highest BS means were obtained for CD group (p=0.004); no significant differences were detected among the three cementation systems for CD
group (p=0.294); U100 cement reached statistically higher BS than the other cementation systems for AC group (p=0.001). The resin cement U100 was statistically higher than the other materials (p=0.0010) regardless the operator skill. The BS in the cervical third was statistically higher than in the TM and TA (p<0.0001). It can be concluded that the bond strength to the root canal is significantly affected by the operator skill, cementation system and root region. / O propósito desse estudo foi avaliar a influência do operador e do sistema de cimentação na resistência de união (RU) de pino de fibra de vidro à dentina radicular
nos diferentes terços radiculares. Quarenta e oito incisivos centrais superiores humanos extraídos foram seccionados transversalmente imediatamente após a
junção cemento-esmalte, e as raízes foram tratadas endodonticamente. Após uma semana, foi realizado o preparo padronizado dos condutos, e as raízes foram
aleatoriamente divididas em dois grupos (n=24), de acordo com o operador: profissional (CD) vs acadêmico (AC). As raízes foram então subdivididas em três
subgrupos cada (n=8) de acordo com o sistema de cimentação: CD1 e AC1 (Adper Scotchbond Multi-Purpose [SBMP] + RelyX ARC [ARC]), CD2 e AC2 (Adper Single
Bond 2 [SB] + ARC) e CD3 e AC3 (RelyX U100 [U100]). Os pinos de fibra de vidro (Tenax Fiber Trans Esthetic Post System) foram cimentados de acordo com as
recomendações dos fabricantes de cada sistema de cimentação. Após o armazenamento em água a 37o C por uma semana, cada raiz foi seccionada
transversalmente em seis discos com 1 mm de espessura, e os terços coronário (TC), médio (TM) e apical (TA) do canal radicular foram identificados. O teste de push-out foi realizado a uma velocidade de 0,5 mm/min. Os dados obtidos foram analisados estatisticamente por meio do teste ANOVA e pós teste de Tukey (p=0,05). Os valores médios de RU (MPa) e desvio padrão (DP) para cada subgrupo foram: CD1: 12,83±7,26; CD2: 11,46±4,22; CD3: 14,27±6,59; AC1: 9,70±4,37; AC2: 8,02±5,25 e AC3: 13,40±4,93. A RU e DP para o grupo dos CD e dos AC foram 12,85±6,18 e 10,37±5,30, respectivamente. Em relação aos terços radiculares, as médias e o DP foram: TC: 14,46±5,55; TM: 10,04±5,07 e TA: 10,35± 6,01. As médias e DP para os sistemas de cimentação foram: SBMP + ARC: 11,27±6,13; SB + ARC: 9,74±5,03 e U100: 13,83±5,77. As maiores médias de RU foram obtidas para o grupo dos CD (p=0,004); não houve diferenças significativas entre os três sistemas de cimentação para o grupo dos CD (p=0,294); o cimento U100 foi estatisticamente superior aos demais sistemas de cimentação para o grupo dos AC (p=0,001). O cimento resinoso U100 foi estatisticamente superior aos demais sistemas de cimentação (p=0,001) independente do operador. A RU no terço coronário foi estatisticamente superior aos TM e TA (p<0,0001). Pode-se concluir que a resistência de união do canal radicular foi significativamente afetada pelo operador, sistema de cimentação e região radicular.
|
Page generated in 0.0891 seconds