• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 31
  • Tagged with
  • 31
  • 31
  • 12
  • 12
  • 10
  • 9
  • 8
  • 8
  • 7
  • 7
  • 7
  • 7
  • 7
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Influência da quitosana na biomodificação da dentina após remoção seletiva da lesão de cárie utilizando laser de ER:YAG. Análise clínica, da adaptação marginal da réplica da restauração e microbiológica / Influence of chitosan on dentin biomodification after selective removal of caries lesion using Er: YAG laser. Clinical longitudinal, photographic analysis, marginal adaptation of the replica of the restoration and microbiological

Santos, Raí Matheus Carvalho 04 December 2018 (has links)
O objetivo deste estudo clínico foi avaliar a influência da quitosana na biomodificação da dentina após a remoção seletiva das lesões de cárie com o laser de Er:YAG em dentes decíduos, quanto à redução da quantidade de Streptococus mutans e Lactobacillus ssp, e o comportamento clínico das restaurações realizadas. A amostra foi composta por 52 crianças que apresentaram lesão de cárie ativa atingindo dentina, localizada na superfície oclusal em molar decíduo. Para a análise microbiológica (n=10), os dentes foram distribuídos aleatoriamente em 4 grupos de acordo com a remoção seletiva das lesões de cárie: laser de Er:YAG (250mJ/4Hz) ou contra-ângulo (método convencional) e o tratamento da superfície da dentina: sem biomodificação e com biomodificação (gel de quitosana a 2,5%). Foram realizadas coletas da dentina infectada, dentina afetada e após a biomodificação com gel de quitosana a 2,5%. As unidades formadoras de colônias (UFC/mg) foram contadas e os dados foram analisados por meio do teste Shapiro-Wilk e teste de Mann-Whitney para o laser de Er:YAG após aplicação da quitosana. Após a remoção seletiva da lesão de cárie com o laser de Er:YAG houve redução significativa na quantidade de S. mutans (p=0,0068). Para Lactobacillus ssp não foi observada diferença significante entre os métodos de remoção (p=0,089). Após a biomodificação com gel de quitosana a 2,5%, houve redução significativa na quantidade de S. mutans, para ambos os métodos de remoção (p=0,0524). A aplicação de quitosana promoveu redução da quantidade de Lactobacillus ssp, após remoção seletiva pelo método convencional, mas não com laser de Er:YAG (p=0,000487). Para a análise clínica os dentes foram restaurados com adesivo (Single Bond Universal/3M) e resina composta (Z350 Filtek/3M) e avaliados nos períodos de 7 dias (baseline), 6 meses e 1 ano, utilizando os critérios USPHS modificados. Foram realizadas imagens fotográficas para auxiliar na análise clínica das restaurações. Para análise da adaptação marginal da réplica da restauração em microscopia eletrônica, os dentes foram moldados com silicona de adição. Os dados obtidos na análise clínica foram submetidos aos testes não-paramétrico de Kruskal Wallis e complementar de Dun (p< 0.05). Na análise clínica observou-se diferença significativa para a remoção seletiva da lesão da cárie utilizando o laser de Er:YAG com relação aos critérios descoloração e adaptação marginal (p<0,05). Concluiu-se que o laser de Er:YAG reduziu a quantidade de S. mutans e Lactobacillus ssp e a biomodificação com gel de quitosana a 2,5% foi efetiva para potencializar o efeito antimicrobiano, e que o comportamento clínico das restaurações não foi influenciado pelo método de remoção da lesão de cárie e biomodificação da dentina afetada / The objective of this clinical study was to evaluate the effect of Er: YAG laser for the removal of caries lesions in primary teeth, followed by the biomodification of dentin affected with 2.5% chitosan gel, reducing the amount of Streptococcus mutans and Lactobacillus ssp, and the clinical behavior of the performed restorations. The sample consisted of 52 children who presented lesions of active caries reaching dentin, located on the occlusal surface in a deciduous molar. For the microbiological analysis (n = 10), the teeth were randomly distributed in 4 groups according to the selective removal of caries lesions: Er: YAG laser (250mJ / 4Hz) or contra-angle (conventional method) and treatment of the dentin surface: without biomodification and with biomodification (chitosan gel). Dentin tissue was collected in three periods: before selective removal of the caries lesion, after selective removal of the caries lesion and after the dentin biomodification with chitosan gel. The colony forming units (CFU/mg) were counted and the data were analyzed by means of the Shapiro-Wilk test and Mann-Whitney test for the Er: YAG laser after application of chitosan. After the selective removal of the caries lesion with Er:YAG laser there was a significant reduction in the amount of S. mutans (p = 0.0068). For Lactobacillus ssp, no significant difference was observed between the removal methods (p = 0.089). After biomodification with 2.5% chitosan gel, there was a significant reduction in the amount of S. mutans, for both removal methods (p=0.0524). The application of chitosan promoted reduction of the amount of Lactobacillus ssp after selective removal by the conventional method, but not with Er: YAG laser (p = 0.000487). For the clinical analysis, the teeth were restored with adhesive (Single Bond Universal / 3M) and composite resin (Z350 Filtek / 3M) and evaluated in 7-day periods (baseline), 6 months and 1 year using modified USPHS criteria. Photographic images were taken to aid in the clinical analysis of the restorations. For analysis of the marginal adaptation of the replica of the restoration in electron microscopy, the teeth were molded with addition silicone. The data obtained in the clinical analysis were submitted to nonparametric Kruskal Wallis tests and Dun\'s complement (p<0.05). In the clinical analysis, a significant difference was observed for the selective removal of the caries lesion using the Er: YAG laser in relation to the descoloration and marginal adaptation criteria (p<0.05). It was concluded that the Er: YAG laser reduced the amount of S. mutans and Lactobacillus ssp and the biomodification with chitosan was effective to potentiate the antimicrobial effect, and that the clinical behavior of the restorations was not influenced by the method of removing the lesion from caries and biomodification of the affected dentin
2

Influência de dois sistemas adesivos e de duas técnicas de fotopolimerização na microinfiltração marginal de restaurações Classe V após preparo com alta rotação e condicionamento com laser de Er:YAG.

Zumaêta, Gardenia Mascarenhas de Oliveira January 2004 (has links)
Submitted by Suelen Reis (suziy.ellen@gmail.com) on 2013-04-23T17:35:07Z No. of bitstreams: 1 Tese- Gardenia.pdf: 19363114 bytes, checksum: c01ed552fcb0218cdc0e6264660d5152 (MD5) / Approved for entry into archive by Rodrigo Meirelles(rodrigomei@ufba.br) on 2013-05-08T11:50:49Z (GMT) No. of bitstreams: 1 Tese- Gardenia.pdf: 19363114 bytes, checksum: c01ed552fcb0218cdc0e6264660d5152 (MD5) / Made available in DSpace on 2013-05-08T11:50:49Z (GMT). No. of bitstreams: 1 Tese- Gardenia.pdf: 19363114 bytes, checksum: c01ed552fcb0218cdc0e6264660d5152 (MD5) Previous issue date: 2004 / O propósito deste estudo In Vitro foi avaliar a influência de dois sistemas adesivos e de duas técnicas de fotoativação na microinfiltração marginal de restaurações Classe V após preparo com alta rotação e condicionamento com laser de Er:YAG. Este estudo propôs-se ainda a verificar, através de microscopia eletrônica de varredura, a interface resina/dentina e resina/esmalte todos os grupos experimentais. Foram selecionados cento e doze terceiros molares inferiores os quais foram divididos em dezesseis grupos sendo oitenta dentes para o estudo da microinfiltração marginal (grupos I, II, III, IV, V, VI, VII e VIII) e trinta e dois para a análise através de microscopia eletrônica de varredura (grupos A, B, C, D, E, F, G e H). Em todos os grupos foram preparadas cavidades Classe V, sendo que nos grupos V, E, VI, F, VII, G, VIII e H, após o preparo cavitário, foi feito o condicionamento do esmalte e da dentina com laser de Er:YAG (Kavo Key Laser, 250mW, 3Hz, 300 impulsos). Os grupos I, A, V e E foram restaurados com o sistema Prime & Bond NT/Esthet X e fotoativados com luz halógena; os grupos II, B, VI e F foram restaurados com o sistema Prime & Bond NT/Esthet X e fotoativados com laser de Argônio (l = 488nm); os grupos III, C, VI e G foram restaurados com o sistema Single Bond/Z250 e fotoativados com luz halógena; e os grupos IV, D, VIII e H foram restaurados com o sistema Single Bond/Z250 e fotoativados com laser de Argônio (l = 488nm). Foi empregado o teste Mann Whintey para o estudo de microinfiltração marginal e os resultados mostraram diferenças significativas (p<0,05) em dentina entre os grupos condicionados com laser de Er:YAG quando o sistema restaurador foi alterado, mostrando menores níveis de infiltração do corante quando o sistema Single Bond/Z250 foi utilizado, independente da fonte de luz empregada (comparação entre os grupos V e VII e grupos VI e VIII). Estas diferenças foram constatadas à luz da microscopia eletrônica de varredura que mostrou nos grupos G e H ausência de fendas e uma maior lisura de superfície sugestivas de um melhor imbricamento micromecânico. Utilizando-se o sistema Single Bond o laser de Argônio apresentou menores níveis de microinfiltração marginal do que a luz halógena (comparação entre os grupos VII e VIII). Em todos os grupos restaurados com o sistema Prime & Bond NT/Esthet X foi verificada a presença de fendas na interface resina/dentina e resina/ esmalte, iguais ou superiores a 10µm. Nas condições experimentais deste estudo pôde-se concluir que o uso do sistema SingleBond/Z250 fotoativado com o laser de Argônio propiciou menores níveis de microinfiltração marginal e um excelente imbricamento micromecânico, observado sob microscopia eletrônica de varredura, sendo mais adequado para a realização de restaurações em cavidades Classe V condicionadas com laser de Er:YAG. / Salvador
3

Estudo comparativo da influência do condicionamento do esmalte humano e bovino com laser de Er:YAG sobre a resistência de união de um sistema adesivo convencional e de um sistema adesivo autocondicionante

Souza, Ana Carolina [UNESP] 17 July 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-07-17Bitstream added on 2014-06-13T18:51:40Z : No. of bitstreams: 1 souza_ac_me_sjc.pdf: 436945 bytes, checksum: c438fa364622444e4a9f3eae707f3c6c (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo do estudo foi o de avaliar e comparar a influência do condicionamento do esmalte humano e bovino com laser de Er:YAG sobre a resistência de união de um adesivo convencional e de um adesivo autocondicionante. Foram utilizados 60 incisivos bovinos e 60 faces de terceiros molares humanos que foram desgastados com lixa d`água 600 até a obtenção de uma superfície plana de esmalte. A área de união foi delimitada por uma fita adesiva com perfuração de 3 mm de diâmetro. Os espécimes foram divididos em dois grupos. O grupo B (Bovino) e grupo H (Humano). Depois, cada grupo foi subdivido em subgrupos de acordo com o tratamento de superfície: o grupo L que recebeu a aplicação de laser de Er:YAG a 300mJ/4hz, enquanto o grupo N não recebeu nenhum tratamento adicional e de acordo com o tipo de adesivo aplicado à superfície convencional (C) ou autocondicionante (A). Os sistemas adesivos foram aplicados na superfície de esmalte exposta e então foram confeccionados cilindros em resina composta para todos os espécimes. Os dentes foram armazenados em água destilada a 37°C/24h e submetidos ao ensaio de cisalhamento a uma velocidade de 0,5 mm/min. As médias (± desvio padrão) em MPa da resistência adesiva foram HNA=14.369(±2.63), BNC=14.18(±4.46), BNA=13.88(±3.92), HNC=12.92(±4.73), BLC=10.63(±3.59), HLA=10.55(±3.26), HLC=9.73(±3.47), BLA=9.45(±1.5). Após o teste de cisalhamento avaliou-se o tipo de fratura por estereomicroscopia. Pode-se concluir que o tratamento da superfície do esmalte humano e bovino com laser reduziu significantemente a resistência de união para os sistemas adesivos utilizados neste estudo e que o esmalte bovino produziu valores de resistência de união estatisticamente semelhantes às do esmalte humano. O tipo de fratura mais predominante para todos os grupos foi a adesiva. / The objective of the study was to evaluate and compare the influence of conditioning the human enamel and bovine with Er:YAG laser on the bond strength of a conventional adhesive and a self-etching adhesive. 60 bovines incisors and 60 sides of third molars humans were ground into a flat enamel surface with a 600 grit-sand paper. An adhesive tape with a 3mm diameter punch delimited the junction area. The specimens were divided into two groups. The group B (Bovine) and Group H (Human). Then each group was divided into subgroups according to the treatment of surface: the L group that received the application of laser of Er: YAG the 300mJ/4hz, while the group N not received any additional treatment and according to the type of adhesive applied to conventional adhesive (C) or self-etching (A). The adhesive systems were applied to the surface of enamel and then exposed cylinders were made in composite resin for all specimens. The teeth were stored in distilled water to 37º C/24h and subjected to shear test at 0.5 mm/min speed. The mean values (± standard deviation) in MPa of the shear bond strength were: HNA=14.369(±2.63), BNC=14.18(±4.46), BNA=13.88(±3.92), HNC=12.92(±4.73), BLC=10.63(±3.59), HLA=10.55(±3.26), HLC=9.73(±3.47), BLA=9.45(±1.5). After the test of shear evaluated the type of fracture by stereomicroscopy. It was concluded that treatment of the enamel surface of human and bovine with laser significantly reduced the strength for the adhesive systems used in this study and that the enamel beef produced values of resistance from union statistically similar to those of human enamel. The most predominant type of fracture for all groups was the adhesive
4

Análise morfológica da dentina irradiada pelo laser de Er:YAG (SSP) com diferentes larguras de pulso / Effect of Er:YAG (SSP) laser pulse widths on dentin - morphological analysis

Trevelin, Lívia Tosi 30 January 2015 (has links)
Este estudo se propôs a analisar as características morfológicas da dentina humana irradiada com laser de Er:YAG utilizando diferentes larguras temporal de pulso nos protocolos de preparo cavitário e pré-tratamento da dentina. Foram utilizados 18 molares humanos que foram seccionados no sentido mésio-distal e amelocementário obtendo-se um disco plano de dentina. Em seguida foram lixados com uma sequência decrescentes de lixas para padronizar os espécimes em 2mm de espessura. Os grupos experimentais foram compostos a partir de 2 fatores de variação: 1) indicação clínica - preparo cavitário (E=200mJ/20Hz), e pré-tratamento (E=80mJ/2Hz); e 2) largura temporal de pulso - 50, 300 e 600µs. Assim formaram-se 6 grupos experimentais com (n=3): G1(E=200mJ/20Hz/50µs); G2(E=200mJ/20Hz/300µs); G3(E=200mJ/20Hz/600µs); G4(E=80mJ/2Hz/50µs); G5(E=80mJ/2Hz/300µs); G6(E=80mJ/2Hz/600µs). Os espécimes foram irradiados com o laser de Er:YAG com comprimento de onda de 2,94µm, de modo não contato, com um distância de 7mm do feixe de saída, sob irrigação de 60ml/min de água e 40ml/min de ar. Após a irradiação, os espécimes foram processados e destinados à avaliação descritiva das imagens obtidas em Microscopia Eletrônica de Varredura (MEV), nos diferentes grupos experimentais. A análise morfológica dos grupos irradiados revelou uma superfície irregular, ausência de smear layer que expõe a abertura dos túbulos dentinários, dentina peritubular evidente e, sem indícios de carbonização e derretimento para todos os protocolos utilizados. Os resultados deste estudo in vitro mostraram que a irradiação com o laser de Er:YAG promoveram um padrão morfológico microrretentivo característico de ablação para todos os grupos testados e os grupos G1 e G4, que utilizaram a menor largura temporal de pulso (50 ?s), apresentaram uma superfície mais rugosa quando comparados aos demais grupos. Por fim, podemos concluir que a largura temporal de pulso influência nas características morfológicas da dentina irradiada nas diferentes indicações clínicas testadas, preparo cavitário e pré-tratamento. A menor largura de pulso (50 µs) produz uma morfologia mais irregular quando comparada as maiores larguras de pulsos (300 e 600 µs). / This study evaluated the morphological characteristics of Er:YAG laser irradiated dentin using different temporal pulses width on the protocols of cavity preparation and dentin pretreatment. Eighteen human molars were cut longitudinally in a mesiodistal direction and amelocemental junction providing dentin disks. Samples were polished in a decreasing silicon carbide paper to obtain standard 2mm thick disks. The experimental groups were divided by two variables: 1) clinical protocol - cavity preparation (E=200mJ/20Hz) and pretreatment (E=80mJ/2Hz); and 2) temporal pulse width - 50, 300 and 600µs. Therefore, six experimental groups were (n=3): G1(E=200mJ/20Hz/50µs); G2(E=200mJ/20Hz/300µs); G3(E=200mJ/20Hz/600µs); G4(E=80mJ/2Hz/50µs); G5(E=80mJ/2Hz/300µs); and G6(E=80mJ/2Hz/600µs). The samples were irradiated with the Er.YAG laser using wave-length of 2.94µm, in a non contact mode at a focal distance of 7mm from the target point under continuous water spray of 60-40ml/min. After the irradiation, the samples were processed and evaluated by scanning electron microscopic evaluation (SEM). The morphological analysis on the irradiated groups showed an irregular dentin surface, without smear layer, exposed dentinal tubules apertures, evidenced peritubular dentin, without carbonization and melting signs for all groups. A microretentive morphological pattern, characteristic of the ablation process could be observed in all groups. However, groups G1 and G4, that used 50?s of temporal pulse width, presented a greater irregularity when compared to other groups. In conclusion, the temporal pulse width interfere on the morphological characteristic of the irradiated dentin, regardless of clinical protocol, cavity preparation and pretreatment. The shorter the pulse width (50µs), the greater the surface irregularity.
5

Influência de diferentes protocolos de irradiação do laser de Er:YAG na morfologia dentinária, na formação da camada híbrida e na resistência adesiva / Er:YAG laser protocols influence on dentin morphology, hybrid layer formation and bond strength

Trevelin, Lívia Tosi 05 December 2018 (has links)
Este estudo longitudinal in vitro avaliou a ação de diferentes larguras de pulso empregadas no protocolo de preparo cavitário e pré-tratamento dentinário com o laser de Er:YAG sobre a ultramorfologia da dentina, a micromorfologia da interface adesiva e resistência de união. Cento e doze molares humanos foram seccionados, obtendo-se uma dentina de profundidade média e, em seguida, foram distribuídos de acordo com os protocolos de irradiação da superfície dentinária: preparo cavitário (200 mJ/20 Hz) e pré-tratamento (80 mJ/2 Hz). Os fatores em estudo foram a largura de pulso (50 ?s, 300 ?s e 600 ?s) e tempo de armazenamento (24 h e 1 ano). Para cada condição de tratamento de superfície (protocolo de irradiação), foi considerado um grupo controle, sem irradiação. Os espécimes foram avaliados por diferentes métodos, a saber: análise da ultramorfologia por microscopia eletrônica de transmissão (MET) (n=3); avaliação da micromorfologia da interface adesiva por meio de microscopia confocal (n=3); avaliação da matriz orgânica e fibrilas colágenas por meio da Segunda Gerão Harmônica (n=3). Foram realizadas também a avaliação da resistência de união por ensaio de microcisalhamento nos espécimes submetidos ao protocolo de pré-tratamento da dentina (?SBS) (n=12) e por ensaio de microtração (?TBS) (n=11) nos espécimes submetidos ao protocolo de irradiação de preparo cavitário. Os experimentos de microscopia confocal e resistência de união foram realizados utilizando um sistema adesivo autocondicionante (Scotchbond Universal, 3M ESPE, EUA) em conjunto a uma resina composta (Z350 XT, 3M ESPE, EUA). Estes espécimes foram analisados após 24 hs e 1 ano de armazenamento em saliva artificial. Os dados quantitativos obtidos nos ensaios de resistência de união foram analisados por meio do teste de ANOVA (dois fatores) e do teste de comparações múltiplas de Tukey (? = 0,05). Os dados qualitativos foram comparados e descritos detalhadamente. Os resultados de resistência de união imediato dos grupos irradiados mostraram valores mais baixos quando comparados ao grupo controleo, independente do protocolo empregado assim como da largura de pulso utilizada. Os baixos valores expressos nos ensaios de resistência de união podem ser justificados pelas alterações na ultraestrutura da dentina irradiada com o laser de Er:YAG, que denotam uma clara alteração da matriz orgânica com desnaturação das fibrilas colágenas, como demostrada pelas imagens de SGH e MET. Desta forma, as alterações nas estruturas orgânicas da dentina prejudicaram a formação da uma camada híbrida consistente que levou à degradação das interfaces adesivas e consequente redução dos valores de resistência de união em 24 h. Todos os espécimes ensaiados no teste de microtração apresentaram redução significativa após 1 ano de armazenamento em saliva artificial, independente do tratamento realizado. Entretanto, os espécimes ensaiados no teste de microcisalhamento não apresentaram redução significativa após o mesmo período de armazenamento (1-ano). Embora o protocolo de pré-tratamento tenha alterado os componentes orgânicos da dentina, essas alterações não foram suficientes para reduzir os valores de resistência de união após 1 ano de armazenamento. Sendo assim, o emprego do laser de Er:YAG, em ambos os protocolos investigados, resultaram em modificações permanentes nos componentes orgânicos da dentina, que infleuncirama negativamente os valores de resistência de união a esse substrato. / This longitudinal in vitro study evaluated the action of different pulse widths employed in the protocol of cavity preparation and pre-treatment with the Er: YAG laser on the ultramorphology of dentin, the micromorphology of the adhesive interface and bond strength. One hundred and twelve human molars were sectioned to obtain a medium depth dentin and then distributed according to the dentin surface irradiation protocols: cavity preparation (200 mJ / 20 Hz) and pretreatment (80 mJ / 2 Hz). The factors under study were the pulse width (50 ?s, 300 ?s and 600 ?s) and storage time (24 h and 1 year). For each surface treatment condition (irradiation protocol), it was considered a control group, without irradiation. The specimens were evaluated by different methods, such as: ultramorphology analysis by transmission electron microscopy (MET) (n = 3); analysis of the adhesive-interfaces by confocal microscopy (n = 3); evaluation of the organic matrix and collagen fibrils by Second Harmonic Generation (n = 3). The bond strength was evaluated by micro-shear test in the specimens submitted to the pre-treatment protocol (?SBS) (n = 12) and by microtensile test (?TBS) (n = 11) in specimens submitted to cavity preparation`s protocol. Confocal microscopy and bond strength experiments were performed using a self-etching adhesive system (Scotchbond Universal, 3M ESPE, USA) together with a composite resin (Z350 XT, 3M ESPE, USA). These specimens were analyzed after 24 h and 1 year of storage in artificial saliva. The quantitative data obtained in the bond strength tests were analyzed using the ANOVA test (two factors) and Tukey\'s multiple comparison test (? = 0.05). Qualitative data were compared and described in detail. The results of immediate bond strength of the irradiated groups showed lower values when compared to the control group, regardless of the protocol used as well as the pulse width used. The low values expressed in the bond strength tests can be justified by the changes in the ultrastructure of the dentin irradiated with the Er: YAG laser, which denote a clear alteration of the organic matrix and collagen fibrils, as observed in SGH and MET images. In this way, the changes in the organic structures of dentin impaired the formation of a consistent hybrid layer that lead to the degradation of the adhesive-interfaces and consequent drop of bond strength values at 24 h. All specimens tested in the microtensile test showed a significant reduction of bond strength after 1 year of saliva storage, regardless treatment performed. However, the specimens tested in the micro-shear test did not show significant reduction of bond strength after the same storage period (1-year). Although the pre-treatment protocol altered the organic components of dentin, these changes were not enough to reduce bond strength values after 1 year of storage. Thus, the use of the Er: YAG laser, in both protocols investigated, resulted in permanent modifications in the organic components of the dentin, which negatively influences the bond strength values to this substrate.
6

Efeito da largura temporal de pulso do Laser de Er:YAG em zircônia pré-sinterizada / Effect of Er:YAG laser pulse widths on pre-sintered zirconia

Silva, Beatriz Togoro Ferreira da 19 October 2015 (has links)
Este estudo se propôs a analisar os efeitos das diferentes larguras temporais de pulso do laser de Er:YAG na rugosidade superficial, na perda de volume do material e na altura do degrau formado em uma Y-TZP (Yttrium-stabilized Tetragonal Zirconia Polycrystal) pré-sinterizada. Foram utilizados 5 blocos de Y-TZP pré-sinterizados destinados ao uso CAD/CAM que foram seccionados, obtendo-se 63 espécimes padronizados. Em seguida, esses espécimes foram lixados com uma sequência decrescente de lixas para padronização da superfície. Os grupos experimentais foram compostos a partir de 1 fator de variação - o tratamento de superfície. Os espécimes foram irradiados com o laser de Er:YAG (Fidelis III Fotona, Eslovênia) - 2,94 ?m, 100 mJ, 15,87J/cm2, 10 Hz, 1W, 7 mm, 60% água/40% ar. Assim formaram-se 7 grupos experimentais (n=9): G1 (50 ?s); G2 (100 ?s); G3 (300 ?s); G4 (600 ?s); G5 (1000 ?s); G6 (Abrasão triboquímica com partículas de 30 ?m); G7 (Sem tratamento). Após os tratamentos de superfície, os espécimes foram sinterizados em forno específico, de acordo com as recomendações do fabricante. Foram capturadas imagens em Microscópio Confocal a Laser 3D de cada espécime e avaliadas por meio de um software. A análise dos grupos irradiados revelou um aumento da rugosidade nos grupos G1, G2, G3 e G4 quando comparados aos grupos G6 e G7. O grupo G5 apresentou superfície totalmente plana e desfavorável para retenção. No que se refere à perda de volume e formação de degrau, os grupos G1, G2 e G3 demonstraram grande perda de volume e grande altura de degrau formado, o que pode levar a uma desadaptação da peça protética. No grupo G4 foram observados valores de rugosidade satisfatórios com pouca perda de volume e pequena altura de degrau formado, semelhante ao que foi notado para a abrasão trioboquímica (G6), podendo ser indicada para tratamento de superfície de Y-TZP pré-sinterizada. A irradiação com o laser de Er:YAG promoveu um padrão morfológico com muitas irregularidades, característico de ablação para os grupos G1, G2, G3 e G4 e, para todos os protocolos utilizados, não foi observada a presença de trincas ou carbonização. Sugere-se que a largura temporal de 600 ?s (G4) seja a mais indicada como alternativa para tratamento de superfície, objetivando a criação de micro-retenções superficiais, com pouca perda de volume de material e que, ao mesmo tempo, não provoque danos à estrutura da cerâmica policristalina. / This study evaluated the effects of different Er:YAG laser pulse width protocols on surface roughness, loss of volume of the material and the step height formed of pre-sintered Yttrium-stabilized tetragonal Zirconia Polycrystal (Y-TZP) by three-dimensional profilometric assessment. Blocks of pre-sintered Y-TZP were cut providing 63 standard 5mm thick samples which were divided by surface treatment, as follows (n=9): G1 (50?s); G2 (100?s); G3 (300?s); G4 (600?s); G5 (1000?s); G6 (tribochemical silica coating); G7 (Untreated). Laser settings: The Er:YAG laser (Fidelis III; Fotona, Ljubljana, Slovenia) 100mJ, 15,87J/cm2, 10Hz, 1W, (60%) and air (40%) cooling. After treated or not, samples were sintered according to the manufacturer\'s recommendations. Roughness, volume loss and step and were analyzed by 3D profilometric assessment with confocal laser microscopy. Irradiated groups showed an increased roughness in the groups G1, G2, G3 and G4 when compared to G6 and G7 groups. The G5 group showed a completely flat and unfavorable surface for retention. The groups G1, G2 and G3 shown great loss of volume and the step height formed, which can lead to a gap on the crowns. In G4 were observed satisfactory roughness with little loss of volume and the step height formed similar to G6. Irrespective of laser protocol, any of the specimens showed presence of cracks and carbonization. It is suggested that the pulse width 600?s (G4) is the most suitable pulse width protocol as an alternative surface treatment, promoting micro-retention, with little loss of volume of material, comparable to gold standard treatment.
7

Análise morfológica da dentina irradiada pelo laser de Er:YAG (SSP) com diferentes larguras de pulso / Effect of Er:YAG (SSP) laser pulse widths on dentin - morphological analysis

Lívia Tosi Trevelin 30 January 2015 (has links)
Este estudo se propôs a analisar as características morfológicas da dentina humana irradiada com laser de Er:YAG utilizando diferentes larguras temporal de pulso nos protocolos de preparo cavitário e pré-tratamento da dentina. Foram utilizados 18 molares humanos que foram seccionados no sentido mésio-distal e amelocementário obtendo-se um disco plano de dentina. Em seguida foram lixados com uma sequência decrescentes de lixas para padronizar os espécimes em 2mm de espessura. Os grupos experimentais foram compostos a partir de 2 fatores de variação: 1) indicação clínica - preparo cavitário (E=200mJ/20Hz), e pré-tratamento (E=80mJ/2Hz); e 2) largura temporal de pulso - 50, 300 e 600µs. Assim formaram-se 6 grupos experimentais com (n=3): G1(E=200mJ/20Hz/50µs); G2(E=200mJ/20Hz/300µs); G3(E=200mJ/20Hz/600µs); G4(E=80mJ/2Hz/50µs); G5(E=80mJ/2Hz/300µs); G6(E=80mJ/2Hz/600µs). Os espécimes foram irradiados com o laser de Er:YAG com comprimento de onda de 2,94µm, de modo não contato, com um distância de 7mm do feixe de saída, sob irrigação de 60ml/min de água e 40ml/min de ar. Após a irradiação, os espécimes foram processados e destinados à avaliação descritiva das imagens obtidas em Microscopia Eletrônica de Varredura (MEV), nos diferentes grupos experimentais. A análise morfológica dos grupos irradiados revelou uma superfície irregular, ausência de smear layer que expõe a abertura dos túbulos dentinários, dentina peritubular evidente e, sem indícios de carbonização e derretimento para todos os protocolos utilizados. Os resultados deste estudo in vitro mostraram que a irradiação com o laser de Er:YAG promoveram um padrão morfológico microrretentivo característico de ablação para todos os grupos testados e os grupos G1 e G4, que utilizaram a menor largura temporal de pulso (50 ?s), apresentaram uma superfície mais rugosa quando comparados aos demais grupos. Por fim, podemos concluir que a largura temporal de pulso influência nas características morfológicas da dentina irradiada nas diferentes indicações clínicas testadas, preparo cavitário e pré-tratamento. A menor largura de pulso (50 µs) produz uma morfologia mais irregular quando comparada as maiores larguras de pulsos (300 e 600 µs). / This study evaluated the morphological characteristics of Er:YAG laser irradiated dentin using different temporal pulses width on the protocols of cavity preparation and dentin pretreatment. Eighteen human molars were cut longitudinally in a mesiodistal direction and amelocemental junction providing dentin disks. Samples were polished in a decreasing silicon carbide paper to obtain standard 2mm thick disks. The experimental groups were divided by two variables: 1) clinical protocol - cavity preparation (E=200mJ/20Hz) and pretreatment (E=80mJ/2Hz); and 2) temporal pulse width - 50, 300 and 600µs. Therefore, six experimental groups were (n=3): G1(E=200mJ/20Hz/50µs); G2(E=200mJ/20Hz/300µs); G3(E=200mJ/20Hz/600µs); G4(E=80mJ/2Hz/50µs); G5(E=80mJ/2Hz/300µs); and G6(E=80mJ/2Hz/600µs). The samples were irradiated with the Er.YAG laser using wave-length of 2.94µm, in a non contact mode at a focal distance of 7mm from the target point under continuous water spray of 60-40ml/min. After the irradiation, the samples were processed and evaluated by scanning electron microscopic evaluation (SEM). The morphological analysis on the irradiated groups showed an irregular dentin surface, without smear layer, exposed dentinal tubules apertures, evidenced peritubular dentin, without carbonization and melting signs for all groups. A microretentive morphological pattern, characteristic of the ablation process could be observed in all groups. However, groups G1 and G4, that used 50?s of temporal pulse width, presented a greater irregularity when compared to other groups. In conclusion, the temporal pulse width interfere on the morphological characteristic of the irradiated dentin, regardless of clinical protocol, cavity preparation and pretreatment. The shorter the pulse width (50µs), the greater the surface irregularity.
8

Efeito da largura temporal de pulso do Laser de Er:YAG em zircônia pré-sinterizada / Effect of Er:YAG laser pulse widths on pre-sintered zirconia

Beatriz Togoro Ferreira da Silva 19 October 2015 (has links)
Este estudo se propôs a analisar os efeitos das diferentes larguras temporais de pulso do laser de Er:YAG na rugosidade superficial, na perda de volume do material e na altura do degrau formado em uma Y-TZP (Yttrium-stabilized Tetragonal Zirconia Polycrystal) pré-sinterizada. Foram utilizados 5 blocos de Y-TZP pré-sinterizados destinados ao uso CAD/CAM que foram seccionados, obtendo-se 63 espécimes padronizados. Em seguida, esses espécimes foram lixados com uma sequência decrescente de lixas para padronização da superfície. Os grupos experimentais foram compostos a partir de 1 fator de variação - o tratamento de superfície. Os espécimes foram irradiados com o laser de Er:YAG (Fidelis III Fotona, Eslovênia) - 2,94 ?m, 100 mJ, 15,87J/cm2, 10 Hz, 1W, 7 mm, 60% água/40% ar. Assim formaram-se 7 grupos experimentais (n=9): G1 (50 ?s); G2 (100 ?s); G3 (300 ?s); G4 (600 ?s); G5 (1000 ?s); G6 (Abrasão triboquímica com partículas de 30 ?m); G7 (Sem tratamento). Após os tratamentos de superfície, os espécimes foram sinterizados em forno específico, de acordo com as recomendações do fabricante. Foram capturadas imagens em Microscópio Confocal a Laser 3D de cada espécime e avaliadas por meio de um software. A análise dos grupos irradiados revelou um aumento da rugosidade nos grupos G1, G2, G3 e G4 quando comparados aos grupos G6 e G7. O grupo G5 apresentou superfície totalmente plana e desfavorável para retenção. No que se refere à perda de volume e formação de degrau, os grupos G1, G2 e G3 demonstraram grande perda de volume e grande altura de degrau formado, o que pode levar a uma desadaptação da peça protética. No grupo G4 foram observados valores de rugosidade satisfatórios com pouca perda de volume e pequena altura de degrau formado, semelhante ao que foi notado para a abrasão trioboquímica (G6), podendo ser indicada para tratamento de superfície de Y-TZP pré-sinterizada. A irradiação com o laser de Er:YAG promoveu um padrão morfológico com muitas irregularidades, característico de ablação para os grupos G1, G2, G3 e G4 e, para todos os protocolos utilizados, não foi observada a presença de trincas ou carbonização. Sugere-se que a largura temporal de 600 ?s (G4) seja a mais indicada como alternativa para tratamento de superfície, objetivando a criação de micro-retenções superficiais, com pouca perda de volume de material e que, ao mesmo tempo, não provoque danos à estrutura da cerâmica policristalina. / This study evaluated the effects of different Er:YAG laser pulse width protocols on surface roughness, loss of volume of the material and the step height formed of pre-sintered Yttrium-stabilized tetragonal Zirconia Polycrystal (Y-TZP) by three-dimensional profilometric assessment. Blocks of pre-sintered Y-TZP were cut providing 63 standard 5mm thick samples which were divided by surface treatment, as follows (n=9): G1 (50?s); G2 (100?s); G3 (300?s); G4 (600?s); G5 (1000?s); G6 (tribochemical silica coating); G7 (Untreated). Laser settings: The Er:YAG laser (Fidelis III; Fotona, Ljubljana, Slovenia) 100mJ, 15,87J/cm2, 10Hz, 1W, (60%) and air (40%) cooling. After treated or not, samples were sintered according to the manufacturer\'s recommendations. Roughness, volume loss and step and were analyzed by 3D profilometric assessment with confocal laser microscopy. Irradiated groups showed an increased roughness in the groups G1, G2, G3 and G4 when compared to G6 and G7 groups. The G5 group showed a completely flat and unfavorable surface for retention. The groups G1, G2 and G3 shown great loss of volume and the step height formed, which can lead to a gap on the crowns. In G4 were observed satisfactory roughness with little loss of volume and the step height formed similar to G6. Irrespective of laser protocol, any of the specimens showed presence of cracks and carbonization. It is suggested that the pulse width 600?s (G4) is the most suitable pulse width protocol as an alternative surface treatment, promoting micro-retention, with little loss of volume of material, comparable to gold standard treatment.
9

Avaliação da variação da temperatura em amostras de esmalte/dentina e dentina, após irradiação com os lasers de Nd:YAG, Er:YAG (Kavo KEY Laser®) e Er:YAG (Kavo KEY Laser® 3): análise com termômetro de radiação infravermelha / Evaluation of the variance in temperature of the enamel/dentin and dentin samples after irradiation with Nd:YAG, Er:YAG (Kavo KEY Laser®) and Er:YAG (Kavo KEY Laser® 3) – Infrared radiation thermometer analysis

Ciaramicoli, Marcia Tonetti 16 September 2004 (has links)
Desde o desenvolvimento do laser pelo norte-americano Theodore Harold Maiman em 1960, inúmeras pesquisas têm sido realizadas com o objetivo de avaliar os efeitos sobre os tecidos dentais, principalmente os relacionados com o aumento de temperatura no interior da câmara pulpar. Esta pesquisa foi desenvolvida com o objetivo de avaliar a variação de temperatura em amostras de esmalte/dentina e dentina, após irradiação com os lasers de Nd:YAG, Er:YAG (Kavo KEY Laser®) e Er:YAG (Kavo KEY Laser® 3), através de análise com termômetro de radiação infravermelha. Foram selecionados 110 terceiros molares isentos de cárie, obtidos através do Banco de Dentes Permanentes Humanos que pertence à Faculdade de Odontologia da Universidade de São Paulo e o projeto de pesquisa foi aprovado pelo Comitê de Ética em Pesquisa (CEP) com o parecer nº44/03. As coroas foram separadas das raízes por meio de um disco de carborundum e todas as coroas foram totalmente incluídas no interior de um tubo de PVC com resina transparente. Os cortes foram realizados no aparelho de corte Labcut, paralelamente ao longo eixo das coroas, no sentido mésio-distal, para obter 750 amostras, com 5 diferentes espessuras (1mm, 2mm, 3mm, 4mm e 5mm), sendo 350 amostras de esmalte/dentina e 400 amostras de dentina. Foi utilizado um termômetro de radiação infravermelha (MINIRAY 100 XL) para medição da variação de temperatura nos dois lados das amostras (frente e atrás), irradiadas em diferentes condições e parâmetros com os lasers de Nd:YAG, Er:YAG (Kavo KEY Laser®) e Er:YAG (Kavo KEY Laser® 3). Os resultados obtidos com todos os lasers e parâmetros demonstraram que a associação refrigeração + espessura das amostras foi estatisticamente significante, quanto à redução da variação de temperatura em comparação à associação ausência de refrigeração + espessura das amostras. Houve uma diminuição da variação da temperatura estatisticamente significante de acordo com as espessuras das amostras irradiadas sem refrigeração, porém não o suficiente para evitar grandes elevações de temperatura. No geral, as variações das temperaturas foram sempre maiores no lado da frente das amostras, independente do uso ou não de refrigeração. Para o laser de Nd:YAG, houve menores variações de temperatura, estatisticamente significante, nos grupos irradiados sem contato e sem a presença da tinta nanquim, independente da presença ou não de refrigeração. / The laser was developed in 1960 by Theodore Harold Maiman and many researches have been carried out with the aim to evaluate the effects on the dental tissues, mainly the effects related to the increase of temperature inside the pulp chamber. This research was developed with the purpose of evaluating the variance in temperature of the enamel/dentin and dentin samples after irradiation with Nd:YAG, Er:YAG (Kavo KEY Laser®) and Er:YAG (Kavo KEY Laser® 3) and an analysis with the infrared radiation thermometer was done. A hundred and ten teeth without dental caries were selected and obtained from the Human Permanent Teeth Bank that belongs to the Odontology College of the University of São Paulo and this research has been approved by the Ethic Research Committee (CEP), as the document n° 44/03 attests. The roots were separated from the crowns with the carburundum disc; all crowns were totally inserted inside a PVC tube with transparent resin and they were cut axially in the Labcut machine, in the mesio-distal way, to obtain 750 samples with five different thickness (1mm, 2mm, 3mm, 4mm e 5mm), 350 enamel/dentin samples and 400 dentin samples. An infrared radiation thermometer (MINIRAY 100XL) was used to measure the variance in temperature in both sides of the samples (front and behind), irradiated in different conditions and parameters with the Nd:YAG, Er:YAG (Kavo KEY Laser®) and Er:YAG (Kavo KEY Laser® 3). The results showed that the association of the refrigeration + samples’ thickness was statistically significant in the reduction of the variance in temperature when compared to the association of the refrigeration absence + samples’ thickness. There was a statistically significant reduction of the variance in temperature according to the the samples’ thickness irradiated without refrigeration, although it wasn’t enough to avoid high temperature increase. In general, the variance in temperature was always higher in the front of samples, whether there was refrigeration or not. For the Nd:YAG laser, there was a lower variance in temperature, statistically significant, in the groups that were irradiated without contact and black ink, whether there was refrigeration or not.
10

Análise in situ da irradiação com laser de Er:YAG no controle da progressão de lesões de erosão e abrasão do esmalte dental / In situ analysis of Er:YAG laser irradiation to control the progression of erosive and abrasive lesions on tooth enamel

Scatolin, Renata Siqueira 06 February 2015 (has links)
Este estudo, composto por 2 experimentos in situ, teve como objetivo avaliar o efeito do laser de Er:YAG no controle da progressão de lesões de erosão e abrasão no esmalte dental. Incisivos bovinos foram seccionados (5x3x2,5mm), planificados e polidos. Os fragmentos de esmalte (KHN=330±10%) tiveram parte da superfície coberta com resina composta (área de referência), e posteriormente foram submetidos à formação de lesões erosivas com ácido cítrico 1% (pH = 2,3), 5 minutos, 2x/dia, durante 2 dias. No primeiro experimento, 56 espécimes foram divididos em dois grupos de acordo com o tratamento de superfície: irradiados com laser de Er:YAG (5,2J/cm2, 2Hz, 85mJ, 10s) e não irradiados, e subdivididos de acordo com o tipo de desgaste: erosivos (ácido cítrico) e não erosivos (água deionizada). A realização dos desafios foi realizada através da imersão dos dispositivos em 100mL de ácido cítrico ou água deionizada, 3x/dia, de maneira alternada e independente. O desgaste do esmalte foi determinado por um perfilômetro óptico 3D após: formação inicial da lesão erosiva, tratamento da superfície e fase intraoral. A avaliação de desgaste foi verificada por meio de três leituras de cada área em relação a área de referência. Os dados foram analizados através da análise de variância (ANOVA) e do teste Tukey. No primeiro experimento quando utilizou-se água deionizada (desafios não erosivos) na fase intraoral, os espécimes apresentaram menores valores de desgaste comparados aos grupos que foram erodidos, independentemente de terem sido irradiados ou não com laser de Er:YAG. No entanto, quando erodidos na fase intraoral, o grupo irradiado com laser de Er:YAG não diferiu do grupo não irradiado. O desgaste do esmalte foi avaliado qualitativamente por microscopia eletrônica de varredura em 3 espécimes de cada grupo. No segundo experimento, 48 espécimes foram divididos em dois grupos de acordo com o tratamento de superfície: irradiados com laser de Er:YAG (5,2 J/cm2, 2Hz, 85mJ, 10s) e não irradiados, e subdivididos de acordo com o tipo de desgaste: erosivos (ácido cítrico) e erosivos associado a abrasão (ácido cítrico e escovação). A realização dos desafios, foi realizada através da imersão dos dispositivos em 100mL de ácido cítrico e imersão em ácido cítrico+escovação, de cada um dos lados do dispositivo, 3x/dia. A análises de perfilometria e microscopia eletrônica de varredura foram realizadas como descritas nos procedimentos do primeiro experimento. Os dados obtidos no segundo experimento foram submetidos à análise estatística de forma separada e independente do primeiro experimento, utilizando o teste Kruskal- Wallis e o teste Mann-Whitney. Os resultados deste segundo experimento mostraram que após os desafios erosivos e abrasivos, o grupo que foi irradiado com laser de Er:YAG apresentou menores valores de desgaste quando comparados com o grupo que não foi irradiado. O grupo que sofreu apenas erosão e foi irradiado com laser de Er:YAG não diferiu significativamente quanto aos valores de desgaste do grupo não irradiado. Assim, pode-se concluir que o laser de Er:YAG não controlou o desgaste do esmalte quando submetidos apenas a desafios erosivos, porém, foi capaz de controlar o desgaste do esmalte quando submetidos a processos abrasivos subsequentes. / This study, composed of two in situ experiment, evaluated the effect of Er:YAG laser irradiation to control the progression of erosive and abrasive lesions on enamel. Bovine incisors were sectioned (5x3x2.5mm), flattened and polished. The enamel slabs (KHN = 330 ± 10%) with one fourth of the surface covered with resin composite (reference area) were submitted to initial erosion-like lesion formation with 1% citric acid (pH 2,3), 5 min, 2x/day for 2 days. In the first experiment, 56 slabs were divided into two groups according to the surface treatment: irradiated with Er:YAG laser (5,2 J / cm2, 2 Hz, 85 mJ, 10 s) and non-irradiated, and subdivided according to the type of wear: erosive (citric acid) and non-erosive (deionized water). The challenges were performed by immersing the devices in 100 mL citric acid or deionized water, 3x/day, randomly and independently. Enamel loss was determined by an optical 3D profilometer after: initial erosion, surface treatment and intraoral phase. The average of structure loss was verified by three readings of each experimental area comparing with reference area. Data was analyzed using the analysis of variance (ANOVA) and Tukeys test. In the first experiment, when used deionized water (non-erosive challenges) in intraoral phase, the specimens showed lower values of wear compared with the groups that were eroded with citric acid, whether irradiated or non-irradiated with Er:YAG laser. When erosion with citric acid was performed, Er:YAG laser didnt differ from non-irradiated group. The enamel wear was assessed qualitatively by scanning electron microscopy in 3 specimens of each group. In the second experiment, 48 slabs were divided into two groups according to the surface treatment: irradiated with Er:YAG laser (5,2 J/cm2, 2 Hz, 85 mJ, 10 s) and nonirradiated and subdivided according to the type of wear: erosive (citric acid) and erosive associated with abrasive (citric acid + brushing). The challenges were performed by immersing the devices in 100 mL citric acid and citric acid+brushing on each side of the device. The profilometry and scanning electronic microscopy analysis were performed as described in the procedures of the first experiment. The data from the second study were statistically analyzed separately and independently of the first experiment, using the Kruskal-Wallis test and the Mann-Whitney test.The results of the second experiment showed that after erosive and abrasive challenges, the group irradiated with Er:YAG laser showed lower structure loss than nonirradiated group. The group that suffered erosion and was irradiated, did not differ significantly from the non-irradiated group. Thus, it can be concluded the Er:YAG laser irradiation didnt control the enamel loss when submitted to erosive challenges, however, was able to control the enamel loss when submitted to abrasive challenges.

Page generated in 0.0415 seconds