• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 28
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • Tagged with
  • 28
  • 15
  • 15
  • 14
  • 11
  • 9
  • 8
  • 8
  • 7
  • 7
  • 6
  • 6
  • 5
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Avaliação da força muscular inspiratória (Pi Max), da atividade do centro respiratório (P 0.1) e da relação da atividade do centro respiratório/força muscular inspiratória (P 0.1 / Pi Max) sobre o desmame da ventilação mecânica / Evaluation of maximal inspiratory pressure (Pi Max), Airway Occlusion Tracheal Pressure (P 01) and its ratio in weaning outcome of mechanical ventilation

Nemer, Sérgio Nogueira 07 May 2007 (has links)
Introdução: a hipótese deste estudo é de que a Pressão inspiratória máxima, Pressão de oclusão traqueal e sua razão podem predizer a evolução do desmame da ventilação mecânica em uma população mista de Terapia Intensiva. Métodos: A Pi Max , P 0.1 e a razão P 0.1 / Pi Max foram mensuradas em setenta pacientes consecutivos , intubados ou traqueostomizados, e ventilados mecanicamente, que preencheram os critérios para desmame da ventilação mecânica. Após a mensuração da Pi Max, P 0.1 e ainda da freqüência respiratória e volume corrente em litros com o cálculo da relação FR/VC e do produto P 0.1 x FR/VC, os pacientes foram submetidos a um teste de respiração espontânea. Os pacientes que toleraram o teste de respiração espontânea e não precisaram retornar para a ventilação mecânica no período de 24 horas foram considerados desmamados. A sensibilidade, especificidade, valor preditivo positivo, valor preditivo negativo, diagnóstico de acurácia e a área sob a curva ROC (receiver operating characteristic curve) foram calculadas. Resultados: Os valores médios da P 0.1 , Pi Max, P 0.1 / Pi Max, FR / VC e P 0.1 x FR /VC foram de 2,49±1,2, -34,6±13, 0,07±0,01, 75,4±33 e 184,6±123 respectivamente para os pacientes desmamados e 4,36± 2,0, -32,1±11,0 , 0,15± 0,09, 148,4± 42 e 652,9± 358 para os não desmamados da ventilação mecânica. Todos os índices distinguiram entre os pacientes desmamados e não desmamados, à exceção da Pi Max. A sensibilidade para a P 0.1 , Pi Max, P 0.1 / Pi Max, FR / VC e P 0.1 x FR /VC foi de 78,85, 65,38, 80,77, 82,69, 88,46 respectivamente. A especificidade para a P 0.1 , Pi Max, P 0.1 / Pi Max, FR / VC e P 0.1 x FR /VC foi de 72,2, 38,8, 72,2, 83,3, 72,2 respectivamente. Os valores preditivos positivos para a P 0.1 , Pi Max, P 0.1 / Pi Max, FR / VC e P 0.1 x FR /VC foram respectivamente 89,1, 75,5, 89,3, 93,4 e 90,2. Os valores preditivos negativos para a P 0.1 , Pi Max, P 0.1 / Pi Max, FR / VC e P 0.1 x FR /VC foram respectivamente de 54,1, 28,0, 56,5, 62,5 e 68,4. O diagnóstico de acurácia para a P 0.1 , Pi Max, P 0.1 / Pi Max, FR / VC e P 0.1 x FR /VC foi respectivamente de 77,1, 58,5, 78,5, 82,8 e 84,2. As áreas abaixo da curva ROC para a P 0.1 , Pi Max, P 0.1 / Pi Max, FR / VC e P 0.1 x FR /VC foram respectivamente 0,76± 0,06, 0,52±0,08 , 0,78±0,06, 0,90±0,04 e 0,84±0,05. A comparação da áreas abaixo da curva ROC mostrou que os melhores índices foram a relação FR/VC, o produto P 0.1 x FR/VC e a relação P 0.1 / Pi Max não havendo diferença estatística entre eles. A pior área abaixo da curva ROC foi do índice Pi Max. Os índices de desmame da ventilação mecânica P 0.1, Pi Max e P 0.1/ Pi Max não foram diferentes estatisticamente entre os pacientes intubados e traqueostomizados. Conclusão: os melhores índices foram a relação FR/VC, o produto P 0.1 x FR/VC e a relação P 0.1 / Pi Max não havendo diferença estatística entre eles. / Introduction: We hypothesized that maximal inspiratory pressure (Pi Max), airway tracheal occlusion pressure (P 0.1) and its ratio (P 0.1/Pi Max) can be used to predict weaning outcome in a mixed ICU mechanically ventilated patients. Methods: Pi Max, P 0.1 and P 0.1 / Pi Max ratio were measured in seventy consecutive intubated or tracheostomized, mechanically ventilated patients, who fulfilled weaning criteria. After these measurements of Pi Max, P0.1, respiratory rate and expiratory tidal volume (L) with the calculation of f / Vt ratio and the product P0.1x f / Vt , the patients were submitted to a spontaneous breathing trial (SBT) . Those who were able to sustain the SBT and had no need to return to mechanical ventilation in the following 24 hours were considered weaned. The sensitivity, specificity, positive predictive value, negative predictive value, diagnostic accuracy and Receiver- operating-characteristics (ROC) curves for this population were calculated. Results: The mean value of P 0.1 , Pi Max, P 0.1 / Pi Max, FR / VC e P 0.1 x FR /VC were 2,49 ±1,2, -34,6± 13, 0,07± 0,01, 75,4±33 and 184,6±123 respectively for the weaned patients and 4,36± 2,0, -32,1±11,0 , 0,15± 0,09, 148,4± 42 e 652,9± 358 for the not weaned patients. All the indexes distinguished between the weaned and not weaned patient, except for the Pi Max. The sensitivity for the P 0.1 , Pi Max, P 0.1 / Pi Max, FR / VC and P 0.1 x FR /VC were respectively 78,85, 65,38, 80,77, 82,69, 88,46. The specificity for P 0.1 , Pi Max, P 0.1 / Pi Max, FR / VC and P 0.1 x FR /VC were 72,2, 38,8, 72,2, 83,3, 72,2 respectively. The positive predictive value for P 0.1 , Pi Max, P 0.1 / Pi Max, FR / VC and P 0.1 x FR /VC were respectively 89,1, 75,5, 89,3, 93,4 e 90,2. The negative predictive value for P 0.1 , Pi Max, P 0.1 / Pi Max, FR / VC and P 0.1 x FR /VC were respectively 54,1, 28,0, 56,5, 62,5 e 68,4. The diagnostic accuracy for P 0.1 , Pi Max, P 0.1 / Pi Max, FR / VC and P 0.1 x FR /VC were respectively 77,1, 58,5, 78,5, 82,8 e 84,2. The area under the ROC curves for P 0.1 , Pi Max, P 0.1 / Pi Max, FR / VC and P 0.1 x FR /VC were respectively 0,76± 0,06, 0,52±0,08 , 0,78±0,06, 0,90±0,04 e 0,84±0,05. The comparison among the areas under the ROC curves showed that the best weaning indexes were f / Vt ratio, the product P 0.1 x f / Vt and the P0.1/ Pi Max ratio with no statistic differences among them. The Pi Max presented the smaller area under the ROC curve. The weaning indexes P 0.1, Pi Max e P 0.1/ Pi Max were not statistically different between intubated or tracheostomized patients. Conclusion: The best weaning indexes were f/Vt ratio , the product P 0.1 x f/Vt and the P 0.1 / Pi Max ratio with no statistically difference among them.
22

Avaliação da força muscular inspiratória (Pi Max), da atividade do centro respiratório (P 0.1) e da relação da atividade do centro respiratório/força muscular inspiratória (P 0.1 / Pi Max) sobre o desmame da ventilação mecânica / Evaluation of maximal inspiratory pressure (Pi Max), Airway Occlusion Tracheal Pressure (P 01) and its ratio in weaning outcome of mechanical ventilation

Sérgio Nogueira Nemer 07 May 2007 (has links)
Introdução: a hipótese deste estudo é de que a Pressão inspiratória máxima, Pressão de oclusão traqueal e sua razão podem predizer a evolução do desmame da ventilação mecânica em uma população mista de Terapia Intensiva. Métodos: A Pi Max , P 0.1 e a razão P 0.1 / Pi Max foram mensuradas em setenta pacientes consecutivos , intubados ou traqueostomizados, e ventilados mecanicamente, que preencheram os critérios para desmame da ventilação mecânica. Após a mensuração da Pi Max, P 0.1 e ainda da freqüência respiratória e volume corrente em litros com o cálculo da relação FR/VC e do produto P 0.1 x FR/VC, os pacientes foram submetidos a um teste de respiração espontânea. Os pacientes que toleraram o teste de respiração espontânea e não precisaram retornar para a ventilação mecânica no período de 24 horas foram considerados desmamados. A sensibilidade, especificidade, valor preditivo positivo, valor preditivo negativo, diagnóstico de acurácia e a área sob a curva ROC (receiver operating characteristic curve) foram calculadas. Resultados: Os valores médios da P 0.1 , Pi Max, P 0.1 / Pi Max, FR / VC e P 0.1 x FR /VC foram de 2,49±1,2, -34,6±13, 0,07±0,01, 75,4±33 e 184,6±123 respectivamente para os pacientes desmamados e 4,36± 2,0, -32,1±11,0 , 0,15± 0,09, 148,4± 42 e 652,9± 358 para os não desmamados da ventilação mecânica. Todos os índices distinguiram entre os pacientes desmamados e não desmamados, à exceção da Pi Max. A sensibilidade para a P 0.1 , Pi Max, P 0.1 / Pi Max, FR / VC e P 0.1 x FR /VC foi de 78,85, 65,38, 80,77, 82,69, 88,46 respectivamente. A especificidade para a P 0.1 , Pi Max, P 0.1 / Pi Max, FR / VC e P 0.1 x FR /VC foi de 72,2, 38,8, 72,2, 83,3, 72,2 respectivamente. Os valores preditivos positivos para a P 0.1 , Pi Max, P 0.1 / Pi Max, FR / VC e P 0.1 x FR /VC foram respectivamente 89,1, 75,5, 89,3, 93,4 e 90,2. Os valores preditivos negativos para a P 0.1 , Pi Max, P 0.1 / Pi Max, FR / VC e P 0.1 x FR /VC foram respectivamente de 54,1, 28,0, 56,5, 62,5 e 68,4. O diagnóstico de acurácia para a P 0.1 , Pi Max, P 0.1 / Pi Max, FR / VC e P 0.1 x FR /VC foi respectivamente de 77,1, 58,5, 78,5, 82,8 e 84,2. As áreas abaixo da curva ROC para a P 0.1 , Pi Max, P 0.1 / Pi Max, FR / VC e P 0.1 x FR /VC foram respectivamente 0,76± 0,06, 0,52±0,08 , 0,78±0,06, 0,90±0,04 e 0,84±0,05. A comparação da áreas abaixo da curva ROC mostrou que os melhores índices foram a relação FR/VC, o produto P 0.1 x FR/VC e a relação P 0.1 / Pi Max não havendo diferença estatística entre eles. A pior área abaixo da curva ROC foi do índice Pi Max. Os índices de desmame da ventilação mecânica P 0.1, Pi Max e P 0.1/ Pi Max não foram diferentes estatisticamente entre os pacientes intubados e traqueostomizados. Conclusão: os melhores índices foram a relação FR/VC, o produto P 0.1 x FR/VC e a relação P 0.1 / Pi Max não havendo diferença estatística entre eles. / Introduction: We hypothesized that maximal inspiratory pressure (Pi Max), airway tracheal occlusion pressure (P 0.1) and its ratio (P 0.1/Pi Max) can be used to predict weaning outcome in a mixed ICU mechanically ventilated patients. Methods: Pi Max, P 0.1 and P 0.1 / Pi Max ratio were measured in seventy consecutive intubated or tracheostomized, mechanically ventilated patients, who fulfilled weaning criteria. After these measurements of Pi Max, P0.1, respiratory rate and expiratory tidal volume (L) with the calculation of f / Vt ratio and the product P0.1x f / Vt , the patients were submitted to a spontaneous breathing trial (SBT) . Those who were able to sustain the SBT and had no need to return to mechanical ventilation in the following 24 hours were considered weaned. The sensitivity, specificity, positive predictive value, negative predictive value, diagnostic accuracy and Receiver- operating-characteristics (ROC) curves for this population were calculated. Results: The mean value of P 0.1 , Pi Max, P 0.1 / Pi Max, FR / VC e P 0.1 x FR /VC were 2,49 ±1,2, -34,6± 13, 0,07± 0,01, 75,4±33 and 184,6±123 respectively for the weaned patients and 4,36± 2,0, -32,1±11,0 , 0,15± 0,09, 148,4± 42 e 652,9± 358 for the not weaned patients. All the indexes distinguished between the weaned and not weaned patient, except for the Pi Max. The sensitivity for the P 0.1 , Pi Max, P 0.1 / Pi Max, FR / VC and P 0.1 x FR /VC were respectively 78,85, 65,38, 80,77, 82,69, 88,46. The specificity for P 0.1 , Pi Max, P 0.1 / Pi Max, FR / VC and P 0.1 x FR /VC were 72,2, 38,8, 72,2, 83,3, 72,2 respectively. The positive predictive value for P 0.1 , Pi Max, P 0.1 / Pi Max, FR / VC and P 0.1 x FR /VC were respectively 89,1, 75,5, 89,3, 93,4 e 90,2. The negative predictive value for P 0.1 , Pi Max, P 0.1 / Pi Max, FR / VC and P 0.1 x FR /VC were respectively 54,1, 28,0, 56,5, 62,5 e 68,4. The diagnostic accuracy for P 0.1 , Pi Max, P 0.1 / Pi Max, FR / VC and P 0.1 x FR /VC were respectively 77,1, 58,5, 78,5, 82,8 e 84,2. The area under the ROC curves for P 0.1 , Pi Max, P 0.1 / Pi Max, FR / VC and P 0.1 x FR /VC were respectively 0,76± 0,06, 0,52±0,08 , 0,78±0,06, 0,90±0,04 e 0,84±0,05. The comparison among the areas under the ROC curves showed that the best weaning indexes were f / Vt ratio, the product P 0.1 x f / Vt and the P0.1/ Pi Max ratio with no statistic differences among them. The Pi Max presented the smaller area under the ROC curve. The weaning indexes P 0.1, Pi Max e P 0.1/ Pi Max were not statistically different between intubated or tracheostomized patients. Conclusion: The best weaning indexes were f/Vt ratio , the product P 0.1 x f/Vt and the P 0.1 / Pi Max ratio with no statistically difference among them.
23

Efeitos da estratégia da ventilação mecânica na função renal de ratos normais / Effects of mechanical ventilation strategy on renal function in normal rat model

Alexandre Luque 18 December 2008 (has links)
A ventilação mecânica (VM) tem sido recentemente associada ao desenvolvimento de falências orgânicas distais, como um fator contribuinte para a falência renal em pacientes com trauma e fator de risco para diálise e mortalidade em unidade de terapia intensiva (UTI). A estratégia ventilatória adotada pode influenciar estes efeitos. O objetivo do presente estudo é explorar a hipótese de que a estratégia de ventilação mecânica adotada pode influenciar na função renal. Delineamento: Randomizado, investigação animal experimental. Casuística: Ratos machos Wistar, anestesiados, paralisados e ventilados mecanicamente. Intervenção: Dois grupos com seis animais cada foram randomizados para receberem ventilação mecânica com volume corrente (VT) de 8ml/kg (VT8) ou 27ml/kg (VT27). Os parâmetros ajustados para grupo foram: a) VT 8ml/kg; Freqüência respiratória (FR) 60±7 rpm; pressão positiva expiratória final (PEEP) 3 cmH2O; Pico de pressão inspiratória (Pwap) 11.8±2 cmH2O; Pressão média de vias aéreas (Pawm) 6,33±0,22 e b) VT 27ml/kg; FR 30±5 rpm; PEEP 0 cmH2O; Pwap 22.7±4 cmH2O; Pawm 6,50±0,22. Mensurações e Resultados: O grupo VT27 apresentou redução significativa no clearance de inulina após 60 minutos de VM, indicando insuficiência renal aguda (0.6±0.05 ml/min/100g de peso corporal (PC)), e ainda mais acentuada após 90 minutos de VM (0.45±0.05 ml/min/100g de PC) comparada aos valores basais (0.95±0.07 ml/min/100g de PC), p<0.001. Nenhum dos dois grupos sofreram variações significativas em relação as variáveis hemodinâmicas e gasométricas. Conclusões: Observamos que o ritmo de filtração glomerular (RFG) mensurado pelo clearance de inulina é afetado pela estratégia de volume corrente empregado após 60 minutos de VM com 27ml/kg e caindo a valores mais baixo após 90 minutos de VM / Mechanical Ventilation (MV) has been recently associated with development of distal organ failure and it is also a contributor factor for renal failure in trauma patients, and risk factor for dialysis and mortality rate in intensive care unit. The ventilatory strategy adopted might be influenced this effect. The aim of the present study was to explore the hypothesis that mechanical ventilatory strategy may contribute to decreased renal function. Design: Randomized animal laboratory investigation. Subjects: Anesthetized, paralyzed, and mechanically ventilated male Wistar rats. Interventions: Two groups of six rats each were randomized to receive tidal volume of either 8ml/kg or 27 ml/kg. Ventilation strategies for the two groups were as follows: a) 8ml/kg; frequency 60±7 beats/min; positive endexpiratory pressure, 3.0 cm H2O; and peak inspiratory airway pressure (Pawp), 11.8±2 cm H2O; and b) 27ml/kg; frequency 30±5 beats/min; positive end-expiratory pressure, 0 cm H2O; and peak inspiratory airway pressure (Pawp), 22.7±4 cm H2O; Both groups with the same mean airway pressure (Pawm), 6,33±0,21 and 6,5±0,22, respectively. Measurements and main Results: Rats ventilated with high tidal volume (27ml/kg) presented significantly decreased inulin clearance after 60 minutes of mechanical ventilation, indicating acute renal insufficiency (0.6±0.05 ml/min/BW) in comparison with basal values (0.95±0.07 ml/min/BW), p<0.001. We observed decreased in inulin clearance in rats that received high tidal volume, after 60 minutes of ventilation and even more significant at 90 minutes of ventilation (0.45±0.05 ml/min/BW) compared with basal values. No inulin clearance alteration was observed in control ventilation group (0.8±0.05 ml/min/BW basal vs. 0.72±0.03 ml/min/BW 120 min of MV). Conclusion: We concluded that GFR is affected by different strategies of mechanical ventilation, and after 60 minutes of high tidal volume (27ml/kg) ventilation the renal function marked decreased, getting worse after 90 minutes
24

Análise do suporte ventilatório mecânico durante anestesia e sua correlação com as complicações pulmonares pós-operatórias: um estudo observacional / Analysis of the mechanical ventilatory support in anesthesia and its correlation with the postoperative pulmonary complications: an observational study

Hirota, Adriana Sayuri 23 March 2005 (has links)
Introdução: A formação de atelectasia durante a indução anestésica pode ser um dos fatores responsáveis pela ocorrência de complicações pulmonares pós-operatórias (CPP). A aplicação de pressão positiva expiratória ao final da expiração (PEEP), uso criterioso de altas frações inspiradas de oxigênio e a utilização de manobras de recrutamento alveolar no período intra-operatório são recursos utilizados para a prevenção de atelectasia em procedimentos anestésicos. O objetivo deste estudo foi avaliar o modelo de ventilação mecânica adotado em procedimentos anestésicos de longa duração e suas correlações com as complicações pulmonares pós-operatórias. Métodos: Foram avaliadas em estudo observacional as cirurgias com mais de cinco horas de duração. No início do procedimento anestésico, na sala de cirurgia e após o seu término, na unidade de terapia intensiva, os parâmetros ventilatórios utilizados foram anotados e correlacionados com os achados das radiografias torácicas e saturação periférica de oxigênio (SpO2) em ar ambiente. Resultados: Cento e vinte e um pacientes foram observados. O tempo total de anestesia 499,4 ± 159,8 minutos. O volume corrente (VC) determinado no período intraoperatório foi 8,09 ± 2,15 mL/kg e a PEEP utilizada de 3,05 ± 2,31 cmH2O. Houve diferença para a mediana da SpO2 em ar ambiente (96% [95-97] vs 95% [92-96], p <0,001) comparando os períodos pré e pós-operatório. A freqüência de pacientes que apresentaram atelectasia nas radiografias de tórax do período pós-operatório (38,8%) foi significantemente maior que a do período pré-operatório (0%), x2=32,259. Não foi encontrado correlação entre os achados e o tempo de anestesia (p=0,708); a PEEP intra-operatória (p=0,296); tempo de permanência com suporte ventilatório mecânico no pósoperatório (p = 0,146) e tabagismo (p = 0,563). Conclusões: No período intra-operatório o PEEP utilizado em procedimentos de longa duração é baixo. Ocorre queda na SpO2 e aumento na incidência de atelectasia no período pós-operatório em comparação com o pré-operatório. São necessários outros estudos para melhor avaliação dos fatores responsáveis / Introduction: The formation of the atelectasis during the induction of the anesthesia can be one of the factors involved in the occurrence of postoperative pulmonary complications (PPCs). The application of the positive end-expiratory pressure (PEEP), low inpiratory concentrations of oxygen and the alveolar recruitment maneuvers perform in the intraoperative period are approaches used in the prevention of atelectasis in the anesthesia procedures. The objective of this study was to evaluate, in prospective observational study, the pattern of mechanical ventilatory assistence during longer anesthesia procedures and its correlations with the PPCs. Methods: The surgeries procedures longer than five hours have been evaluated in observational study. At the beginning of the anesthesia procedure, in the operatory room and after its terminus, in the intensive care unit, the mechanical ventilation parameters were determined and correlated with the findings in the chest x-rays and peripheral oxygen saturation (SpO2) in room air. Results: One hundred twenty one patients have been observed. The total time of anesthesia was 499,4 ± 159,8 minutes. The tidal volume (VT) in the intraoperative period was 8,09 ± 2,15 mL/kg and the PEEP used was 3,05 ± 2,31 cmH2O. There was a difference for the median of the SpO2 in room air (96% [95-97] vs 95% [92-96], p <0,001) comparing the pre and postoperative periods. The frequency of patients who had presented atelectasis in the chest x-rays of the postoperative period (38,8%) was significantly higher than the preoperative period (0%), x2=32,259. No correlation was found among these findings and the anesthesia time (p=0,708); the intraoperative PEEP used (p=0,296); time with mechanical ventilatory support in the postoperative period (p = 0,146) and smoking habits (p = 0,563). Conclusions: In the intraoperative period, the PEEP is low in longer procedures. The SpO2 decreases and the incidence of the atelectasis increases in the postoperative period, when compared with the preoperative one. Other researches are required for better evaluation of the factors related for the development of the PPCs
25

Mensuração da pressão de dióxido de carbono arterial e expirado em lactentes e crianças sob ventilação mecânica invasiva

Rasera, Carmen Caroline 10 March 2010 (has links)
Capes / Nos pacientes neonatais e pediátricos internados em unidade de terapia intensiva, a monitorização do dióxido de carbono tem grande importância clínica durante a ventilação mecânica invasiva no ajuste dos parâmetros ventilatórios e na detecção de complicações relacionadas à ventilação. O objetivo principal deste estudo é investigar a correlação e o nível de concordância entre a pressão final de dióxido de carbono exalado (PetCO2) e a pressão parcial de dióxido de carbono arterial (PaCO2) em pacientes no período pós-operatório de cirurgia cardíaca, verificando a relação entre ambos os métodos em dois grupos de acordo com a temperatura corporal e as complicações pulmonares associadas. No total, 74 pacientes participaram do grupo 1, com 110 mensurações de PetCO2, PaCO2 medida a 37 °C e corrigida pela temperatura real do paciente. Para toda a amostra, a correlação foi mais significativa com a PaCO2 corrigida (r = 0,92) do que com a medida (r = 0,78), durante todo o período do estudo. A diferença média entre PaCO2 medida e PetCO2 foi 4,42 mmHg e aumentou significativamente durante a instabilidade térmica, enquanto para PaCO2 corrigida a diferença média foi de 1,12 mmHg e permaneceu baixa mesmo durante hipo ou hipertermia. Os resultados obtidos para os 246 pares de PetCO2 e PaCO2 analisados em 42 pacientes ventilados de acordo com o grupo 2, mostraram que os dois métodos foram altamente correlacionados (r = 0,94) e manteve-se elevado mesmo em pacientes com complicações respiratórias. A diferença média entre as mensurações de ambos os métodos foi de -0,71 mmHg e os valores de PetCO2 estavam dentro de 2 mmHg da correspondente PaCO2 em 80,49% das mensurações, indicando uma forte relação. Os resultados deste estudo demonstram que a PetCO2 mensurada pelo capnômetro é tão precisa quanto a PaCO2 mensurada pela gasometria arterial, assim a capnometria pode ser considerada um método de monitorização indireta e não invasiva da PaCO2 em pacientes de terapia intensiva submetidos à ventilação mecânica. / In neonates and pediatrics patients in intensive care units, monitoring of carbon dioxide has great clinical significance during the invasive mechanical ventilation in the adjustment of ventilatory parameters and detection of complications related to ventilation. The objective of this research is to investigate the correlation and level of agreement between end-tidal carbon dioxide pressure (PetCO2) and the partial pressure of arterial carbon dioxide (PaCO2) in patients in the postoperative period of cardiac surgery, verifying the relationship between both methods in two groups according to body temperature and pulmonary complications. Altogether 74 patients were arranged in the group 1 with 110 measurements of PetCO2, PaCO2 measured at 37 ºC and corrected to the real body temperature of the patient. For the whole sample, the correlation was statistically more significant with corrected PaCO2 (r = 0.92) than with the measured (r = 0.78), throughout the study period. The mean difference between measured PaCO2 and PetCO2 was 4.42 mmHg and increased significantly during body temperature instability, while for corrected PaCO2 the mean difference was 1.12 mmHg and remained low even during hypo or hyperthermia. The results for 246 PetCO2 and PaCO2 pairs analyzed in 42 patients ventilated according to group 2, proved that both methods were highly correlated (r = 0.94) and kept elevated even in patients with respiratory complications. The mean difference between the measurements of both methods was -0.71 mmHg and the values of PetCO2 were within 2 mmHg of PaCO2 in 80.49% of the measurements, indicating a high relationship. The results of this study demonstrate that PetCO2 measured by capnometer is as accurate as PaCO2 measured by arterial blood gases, thus the capnometry can be considered an indirect and noninvasive monitoring method of PaCO2 in patients of intensive therapy under mechanical ventilation.
26

Mensuração da pressão de dióxido de carbono arterial e expirado em lactentes e crianças sob ventilação mecânica invasiva

Rasera, Carmen Caroline 10 March 2010 (has links)
Capes / Nos pacientes neonatais e pediátricos internados em unidade de terapia intensiva, a monitorização do dióxido de carbono tem grande importância clínica durante a ventilação mecânica invasiva no ajuste dos parâmetros ventilatórios e na detecção de complicações relacionadas à ventilação. O objetivo principal deste estudo é investigar a correlação e o nível de concordância entre a pressão final de dióxido de carbono exalado (PetCO2) e a pressão parcial de dióxido de carbono arterial (PaCO2) em pacientes no período pós-operatório de cirurgia cardíaca, verificando a relação entre ambos os métodos em dois grupos de acordo com a temperatura corporal e as complicações pulmonares associadas. No total, 74 pacientes participaram do grupo 1, com 110 mensurações de PetCO2, PaCO2 medida a 37 °C e corrigida pela temperatura real do paciente. Para toda a amostra, a correlação foi mais significativa com a PaCO2 corrigida (r = 0,92) do que com a medida (r = 0,78), durante todo o período do estudo. A diferença média entre PaCO2 medida e PetCO2 foi 4,42 mmHg e aumentou significativamente durante a instabilidade térmica, enquanto para PaCO2 corrigida a diferença média foi de 1,12 mmHg e permaneceu baixa mesmo durante hipo ou hipertermia. Os resultados obtidos para os 246 pares de PetCO2 e PaCO2 analisados em 42 pacientes ventilados de acordo com o grupo 2, mostraram que os dois métodos foram altamente correlacionados (r = 0,94) e manteve-se elevado mesmo em pacientes com complicações respiratórias. A diferença média entre as mensurações de ambos os métodos foi de -0,71 mmHg e os valores de PetCO2 estavam dentro de 2 mmHg da correspondente PaCO2 em 80,49% das mensurações, indicando uma forte relação. Os resultados deste estudo demonstram que a PetCO2 mensurada pelo capnômetro é tão precisa quanto a PaCO2 mensurada pela gasometria arterial, assim a capnometria pode ser considerada um método de monitorização indireta e não invasiva da PaCO2 em pacientes de terapia intensiva submetidos à ventilação mecânica. / In neonates and pediatrics patients in intensive care units, monitoring of carbon dioxide has great clinical significance during the invasive mechanical ventilation in the adjustment of ventilatory parameters and detection of complications related to ventilation. The objective of this research is to investigate the correlation and level of agreement between end-tidal carbon dioxide pressure (PetCO2) and the partial pressure of arterial carbon dioxide (PaCO2) in patients in the postoperative period of cardiac surgery, verifying the relationship between both methods in two groups according to body temperature and pulmonary complications. Altogether 74 patients were arranged in the group 1 with 110 measurements of PetCO2, PaCO2 measured at 37 ºC and corrected to the real body temperature of the patient. For the whole sample, the correlation was statistically more significant with corrected PaCO2 (r = 0.92) than with the measured (r = 0.78), throughout the study period. The mean difference between measured PaCO2 and PetCO2 was 4.42 mmHg and increased significantly during body temperature instability, while for corrected PaCO2 the mean difference was 1.12 mmHg and remained low even during hypo or hyperthermia. The results for 246 PetCO2 and PaCO2 pairs analyzed in 42 patients ventilated according to group 2, proved that both methods were highly correlated (r = 0.94) and kept elevated even in patients with respiratory complications. The mean difference between the measurements of both methods was -0.71 mmHg and the values of PetCO2 were within 2 mmHg of PaCO2 in 80.49% of the measurements, indicating a high relationship. The results of this study demonstrate that PetCO2 measured by capnometer is as accurate as PaCO2 measured by arterial blood gases, thus the capnometry can be considered an indirect and noninvasive monitoring method of PaCO2 in patients of intensive therapy under mechanical ventilation.
27

Análise do suporte ventilatório mecânico durante anestesia e sua correlação com as complicações pulmonares pós-operatórias: um estudo observacional / Analysis of the mechanical ventilatory support in anesthesia and its correlation with the postoperative pulmonary complications: an observational study

Adriana Sayuri Hirota 23 March 2005 (has links)
Introdução: A formação de atelectasia durante a indução anestésica pode ser um dos fatores responsáveis pela ocorrência de complicações pulmonares pós-operatórias (CPP). A aplicação de pressão positiva expiratória ao final da expiração (PEEP), uso criterioso de altas frações inspiradas de oxigênio e a utilização de manobras de recrutamento alveolar no período intra-operatório são recursos utilizados para a prevenção de atelectasia em procedimentos anestésicos. O objetivo deste estudo foi avaliar o modelo de ventilação mecânica adotado em procedimentos anestésicos de longa duração e suas correlações com as complicações pulmonares pós-operatórias. Métodos: Foram avaliadas em estudo observacional as cirurgias com mais de cinco horas de duração. No início do procedimento anestésico, na sala de cirurgia e após o seu término, na unidade de terapia intensiva, os parâmetros ventilatórios utilizados foram anotados e correlacionados com os achados das radiografias torácicas e saturação periférica de oxigênio (SpO2) em ar ambiente. Resultados: Cento e vinte e um pacientes foram observados. O tempo total de anestesia 499,4 ± 159,8 minutos. O volume corrente (VC) determinado no período intraoperatório foi 8,09 ± 2,15 mL/kg e a PEEP utilizada de 3,05 ± 2,31 cmH2O. Houve diferença para a mediana da SpO2 em ar ambiente (96% [95-97] vs 95% [92-96], p <0,001) comparando os períodos pré e pós-operatório. A freqüência de pacientes que apresentaram atelectasia nas radiografias de tórax do período pós-operatório (38,8%) foi significantemente maior que a do período pré-operatório (0%), x2=32,259. Não foi encontrado correlação entre os achados e o tempo de anestesia (p=0,708); a PEEP intra-operatória (p=0,296); tempo de permanência com suporte ventilatório mecânico no pósoperatório (p = 0,146) e tabagismo (p = 0,563). Conclusões: No período intra-operatório o PEEP utilizado em procedimentos de longa duração é baixo. Ocorre queda na SpO2 e aumento na incidência de atelectasia no período pós-operatório em comparação com o pré-operatório. São necessários outros estudos para melhor avaliação dos fatores responsáveis / Introduction: The formation of the atelectasis during the induction of the anesthesia can be one of the factors involved in the occurrence of postoperative pulmonary complications (PPCs). The application of the positive end-expiratory pressure (PEEP), low inpiratory concentrations of oxygen and the alveolar recruitment maneuvers perform in the intraoperative period are approaches used in the prevention of atelectasis in the anesthesia procedures. The objective of this study was to evaluate, in prospective observational study, the pattern of mechanical ventilatory assistence during longer anesthesia procedures and its correlations with the PPCs. Methods: The surgeries procedures longer than five hours have been evaluated in observational study. At the beginning of the anesthesia procedure, in the operatory room and after its terminus, in the intensive care unit, the mechanical ventilation parameters were determined and correlated with the findings in the chest x-rays and peripheral oxygen saturation (SpO2) in room air. Results: One hundred twenty one patients have been observed. The total time of anesthesia was 499,4 ± 159,8 minutes. The tidal volume (VT) in the intraoperative period was 8,09 ± 2,15 mL/kg and the PEEP used was 3,05 ± 2,31 cmH2O. There was a difference for the median of the SpO2 in room air (96% [95-97] vs 95% [92-96], p <0,001) comparing the pre and postoperative periods. The frequency of patients who had presented atelectasis in the chest x-rays of the postoperative period (38,8%) was significantly higher than the preoperative period (0%), x2=32,259. No correlation was found among these findings and the anesthesia time (p=0,708); the intraoperative PEEP used (p=0,296); time with mechanical ventilatory support in the postoperative period (p = 0,146) and smoking habits (p = 0,563). Conclusions: In the intraoperative period, the PEEP is low in longer procedures. The SpO2 decreases and the incidence of the atelectasis increases in the postoperative period, when compared with the preoperative one. Other researches are required for better evaluation of the factors related for the development of the PPCs
28

[en] ADDITIVE MANUFACTURING FOR EMERGENCIES: REPLACEMENT PARTS FOR NON-INVASIVE VENTILATORS / [pt] MANUFATURA ADITIVA PARA EMERGÊNCIAS: REPOSIÇÃO DE PEÇAS PARA RESPIRADORES NÃO-INVASIVOS

RAPHAEL DE PINHO VINAGRE 31 August 2023 (has links)
[pt] Esta pesquisa examina as potencialidades e limitações da manufatura aditiva na produção de dispositivos médicos em resposta à crescente demanda global durante a pandemia da COVID-19. A pesquisa busca entender as implicações da adaptação de projetos, da conformidade com regulamentações e da criação de uma cadeia de produção resiliente e sustentável, utilizando impressoras 3D de baixo custo. Além disso, a pesquisa incita reflexões sobre a intersecção entre medicina e design, instigando novas pesquisas neste campo interdisciplinar. O estudo se aprofunda na análise de adaptações de design e na exploração de uma cadeia produtiva alternativa mais resiliente e com menor impacto ambiental. A pesquisa considera a possibilidade de utilizar resíduos hospitalares como matériaprima para a produção de componentes médicos, uma prática que pode reduzir custos de descarte e a pegada de carbono. Além disso, discute a implementação do DRAM (Design, Reciclagem e Manufatura Aditiva Distribuídos) em ambientes hospitalares para responder às demandas de saúde em cenários de interrupção da cadeia de suprimentos. A pesquisa levanta questões importantes sobre a fronteira entre medicina e tecnologia, destacando a importância da responsabilidade ética e social na evolução científica e tecnológica. Argumenta a importância da manutenção adequada dos equipamentos médicos e o papel vital que a manufatura aditiva pode desempenhar na produção rápida de peças de reposição, especialmente em situações de emergência, como a pandemia da COVID-19. Com uma análise detalhada do joelho, um projeto prático desenvolvido durante o mestrado, a pesquisa identifica a necessidade de reestruturação dos processos de fabricação, considerando fatores econômicos e geográficos. A experiência do projeto instigou discussões enriquecedoras sobre o papel do designer, a potência da tecnologia de fabricação digital e a relevância dessa atividade em situações de emergência. Finalmente, a pesquisa conclui que a Reciclagem Distribuída e a Manufatura Aditiva (DRAM) podem se apresentar como uma solução sustentável e descentralizada para a produção de itens críticos em hospitais. Sugere a possibilidade de implementação de um ciclo fechado de produção e consumo de materiais através da fabricação de filamentos a partir de resíduos no próprio local de cuidados de saúde. Isso não só reduziria a dependência de fornecedores externos e a pegada ambiental da produção, mas também poderia melhorar a eficiência e agilidade dos sistemas de saúde em situações de emergência. / [en] This Master s dissertation examines the potentialities and limitations of additive manufacturing in the production of medical devices in response to the growing global demand during the COVID-19 pandemic. The research seeks to understand the implications of project adaptations, compliance with regulations, and the creation of a resilient and sustainable production chain, using low-cost 3D printers. Furthermore, the research instigates reflections on the intersection between medicine and design, stimulating new research in this interdisciplinary field. The study delves into the analysis of design adaptations and explores an alternative production chain that is more resilient and has less environmental impact. The research considers the possibility of using hospital waste as raw material for the production of medical components, a practice that can reduce disposal costs and the carbon footprint. In addition, it discusses the implementation of DRAM (Distributed Recycling and Additive Manufacturing) in hospital environments to respond to health demands in scenarios of supply chain disruption. The research raises important questions about the frontier between medicine and technology, highlighting the importance of ethical and social responsibility in scientific and technological evolution. It argues the importance of proper maintenance of medical equipment and the vital role that additive manufacturing can play in the quick production of replacement parts, especially in emergency situations, such as the COVID-19 pandemic. With a detailed analysis of the elbow, a practical project developed during the master s program, the research identifies the need for restructuring manufacturing processes, taking into account economic and geographic factors. The project s experience instigated enriching discussions about the role of the designer, the power of digital manufacturing technology, and the relevance of this activity in emergency situations.

Page generated in 0.0583 seconds