Spelling suggestions: "subject:"restaurações dentária"" "subject:"restaurações dentários""
1 |
Avaliação de resistência de união de braquetes ortodônticos fixados à cerâmica de dissilicato de lítio com diferentes tratamentos de superfíciePeixoto, Naiany Macedo 04 September 2018 (has links)
Made available in DSpace on 2019-03-30T00:26:47Z (GMT). No. of bitstreams: 0
Previous issue date: 2018-09-04 / Adhesion of orthodontic brackets in ceramic crowns is a challenge found in orthodontic clinical practice. Therefore, the purpose of this study was to evaluate the shear bond strength ofAdhesion of orthodontic brackets in ceramic crowns is a challenge found in orthodontic clinical practice. Therefore, the purpose of this study was to evaluate the shear bond strength of cemented orthodontic brackets to a lithium disilicate dental ceramic, having as variables: ceramic surface treatment, bracket type and thermocycling. For this purpose, 80 rectangular samples of vitreous ceramic based on lithium disilicate (15 mm wide x 13 mm high x 2 mm thick) were made. Samples were included in cylinders of polyvinyl chloride containing chemically activated acrylic resin and initially divided into 4 groups of 20 units according to the surface treatment: 37% phosphoric acid, for 30 seconds; 10% hydrofluoric acid for 60 seconds; blasting with aluminum oxide for 4 seconds; and diamond-tipped roughing for 10 seconds. Each group was divided into two subgroups for Edgwise, metallic and ceramic brackets. Subsequently the groups were subdivided into two new groups: thermocycled or not. The thermocycled samples went through 500 cycles with temperature variations between 5 ° C and 55 ° C. All samples were stored in distilled water at 37 ° C for 24 hours prior to the shear strength test. This test was performed in a universal test machine with a velocity of 1.0 mm /min. The type of failure was also recorded using the IRA (Remaining Adhesive Index) through a 8-fold magnification stereoscope. The numerical values obtained in the shear test were
submitted to descriptive statistical analysis (mean and standard deviation), and the Shapiro- Wilk normality test and the non-parametric Mann-Whitney and Kruskal-Wallis tests were performed. From our results, it was found that there were no statistically significant differences regarding the type of surface treatment and the performance or not of thermocycling, observing a statistically significant difference only in the bracket type, being the union strength in the bracket metal than ceramic. Thus, it can be concluded that neither the type of surface treatment nor the thermocycling performance were decisive in the bond strength of orthodontic brackets to the lithium disilicate ceramic, and the type of bracket is more closely related to the adhesion
quality considering methodological conditions of this research.cemented orthodontic brackets to a lithium disilicate dental ceramic, having as variables: ceramic surface treatment, bracket type and thermocycling. For this purpose, 80 rectangular samples of vitreous ceramic based on lithium disilicate (15 mm wide x 13 mm high x 2 mm
thick) were made. Samples were included in cylinders of polyvinyl chloride containing
chemically activated acrylic resin and initially divided into 4 groups of 20 units according to the surface treatment: 37% phosphoric acid, for 30 seconds; 10% hydrofluoric acid for 60 seconds; blasting with aluminum oxide for 4 seconds; and diamond-tipped roughing for 10 seconds. Each group was divided into two subgroups for Edgwise, metallic and ceramic brackets. Subsequently the groups were subdivided into two new groups: thermocycled or not. The thermocycled samples went through 500 cycles with temperature variations between 5 ° C and 55 ° C. All samples were stored in distilled water at 37 ° C for 24 hours prior to the shear strength test. This test was performed in a universal test machine with a velocity of 1.0 mm /min. The type of failure was also recorded using the IRA (Remaining Adhesive Index) through a 8-fold magnification stereoscope. The numerical values obtained in the shear test were submitted to descriptive statistical analysis (mean and standard deviation), and the Shapiro-
Wilk normality test and the non-parametric Mann-Whitney and Kruskal-Wallis tests were
performed. From our results, it was found that there were no statistically significant differences regarding the type of surface treatment and the performance or not of thermocycling, observing a statistically significant difference only in the bracket type, being the union strength in the bracket metal than ceramic. Thus, it can be concluded that neither the type of surface treatment nor the thermocycling performance were decisive in the bond strength of orthodontic brackets to the lithium disilicate ceramic, and the type of bracket is more closely related to the adhesion
quality considering methodological conditions of this research. / A adesão de braquetes ortodônticos em coroas cerâmicas é um desafio encontrado na prática
clínica ortodôntica. Diante disso, o objetivo do presente estudo foi avaliar a sistência ao cisalhamento de braquetes ortodônticos cimentados a uma cerâmica odontológica à base de dissilicato de lítio, tendo como variáveis: tratamento da superfície cerâmica, tipo de braquete e termociclagem. As 80 amostras retangulares de cerâmica vítrea à base de dissilicato de lítio (15 mm de largura x 13 mm de altura x 2 mm de espessura) foram confeccionadas. Em seguida, as amostras foram incluídas em cilindros de P.V.C. contendo resina acrílica ativada quimicamente e as amostras foram divididas inicialmente em 4 grupos de 20 unidades conforme o tratamento de superfície: ácido fosfórico 37% por 30 segundos (HP); ácido hidrofluorídrico 10% por 60 segundos (HF); jateamento com óxido de alumínio por 4 segundos (SB); e asperização com ponta diamantada por 10 segundos (DW). Cada grupo foi dividido em dois subgrupos para a cimentação com cimento resinoso de braquetes Edgwise: metálico e cerâmico. Os dois novos grupos foram subdivididos em termociclados ou não termociclados. As amostras termocicladas passaram por 500 ciclos com variações de temperatura entre 5°C a 55°C. Todas as amostras foram armazenadas em água destilada a 37° C por 24 horas antes do teste de resistência ao cisalhamento. Este teste foi realizado em máquina de ensaios universal com velocidade de 1 mm/min. O tipo de falha também foi registrado usando o IRA (Índice de Adesivo Remanescente) por meio de um estereoscópio com magnificação de oito vezes. Os valores numéricos obtidos no teste de cisalhamento foram submetidos a¿ análise estatística descritiva (média e desvio padrão), tendo sido realizado o teste de normalidade Shapiro-Wilk e os testes não paramétricos de Kruskal-Wallis e Mann-Whitney. Verificou-se que não houve diferença
estatística significante em relação ao tipo de tratamento de superfície e a realização ou não de termociclagem, observando-se diferença estatisticamente significativa apenas no tipo de braquete, sendo a resistência de união no braquete metálico maior do que no de cerâmica. Assim, o tipo de tratamento de superfície e o envelhecimento por termociclagem não foram decisivos na resistência de união de braquetes ortodônticos à cerâmica de dissilicato de lítio. O tipo de braquete está mais atrelado à qualidade da adesão, sendo o braquete metálico mais resistente nas condições testadas no presente estudo.
|
2 |
Eficácia do uso de ácido fosfórico modificado com proantocianidina na resistência de união de sistemas adesivos simplificadosCollyer, Jamilly Carneiro 28 March 2018 (has links)
Made available in DSpace on 2019-03-30T00:26:44Z (GMT). No. of bitstreams: 0
Previous issue date: 2018-03-28 / Proanthocyanidin (PA) has a proven beneficial effect on the longevity of dentin restorations, with the proposal of simplifying operative steps in a physical conditioning network, avoiding the addition of additional steps. Forty human molars were sectioned by exposing medium dentin and divided into four groups (n = 10) according to the conditioning and adhesive strategy: G1 - 35% phosphoric acid for 15s with Adper Single Bond 2 (SB - 3M ESPE); G2 - 10% phosphoric acid + 2% proanthocyanidin for 30 seconds with SB (3M ESPE); G3 - 35% phosphoric acid for 15s with Universal Single Bond (SBU - 3M ESPE); and G4 - 10% phosphoric acid + 2% proanthocyanidin for 30 seconds with SBU (3M ESPE). It was then made onto a nutrient surface with a composite resin substrate (Filtek Z250 - 3M ESPE). After 24h of storage in distilled water, the specimens were sectioned to obtain resin-dentin sticks (1 mm square cross-sectional area) and subjected to the microtensile test (0.5 mm / min). Statistical analysis was performed through ANOVA and unpaired ttest for analysis between adhesives (¿ = 0.05). The two groups of fractures of each group were observed in scanning electron microscopy (SEM). It was not possible to make the difference between the bands for the values of immediate resistance (p = 0.626). At the same time, the type of adhesive filter, changing only the challenge of overcoming the needs, is difficult to observe (p = 0.146; p = 0.779, for SB and SBU). The effect of phosphoric acid containing 2% proanthocyanidin did not impair the bond strength of immediate treatment to dentin. / A proantocianidina (PA) apresenta ação benéfica comprovada na longevidade de restaurações em dentina, entretanto a necessidade da simplicação de passos operatórios tem gerado a busca da associação de PA a condicionantes de superfície, evitando o acréscimo de passos adicionais. Quarenta molares humanos foram seccionados expondo dentina média e divididos em 4 grupos (n=10) de acordo com a estratégia de condicionamento e adesivo: G1- ácido fosfórico 35% durante 15s com Adper Single Bond 2 (SB - 3M ESPE); G2 ¿ ácido fosfórico a 10% + proantocianidina a 2% durante 30s com SB (3M ESPE); G3 ¿ ácido fosfórico a 35% durante 15s com Single Bond Universal (SBU - 3M ESPE); e G4 ¿ ácido fosfórico a 10% + proantocianidina a 2% durante 30s com SBU (3M ESPE). Em seguida, foi confeccionado sobre a superfície adesiva dos espécimes um platô em resina composta (Filtek Z250 ¿ 3M ESPE) medindo 4mm e armazenados em água destilada. Após 24h de armazenamento, os espécimes foram seccionados em forma de palitos (de 1 mm² de área de secção quadrada) e submetidos ao teste de microtração (0,5 mm/min). A análise estatística foi realizada através dos testes de ANOVA e teste t não-pareado para análise entre adesivos (¿=0,05). Dois dos espécimes fraturados de cada grupo foram observados em microscopia eletrônica de varredura (MEV). Não houve diferença estatística entre os grupos quanto aos valores de resistência de união imediata (p=0,626). Ao se avaliar individualmente o tipo de sistema adesivo, alterando-se apenas o tratamento da superfície pelo condicionante, também não foi observado diferenças (p=0,146; p=0,779, respectivamente para SB e SBU). O tratamento com ácido fosfórico a 10% modificado contendo 2% de proantocianidina não prejudicou a resistência de união imediata em dentina.
|
3 |
Avaliação da microinfiltração e nanoinfiltração em restaurações de resina composta - Influência do laser no preparo cavitário e no pré-tratamento dentinário /Araujo, Rosehelene Marotta. January 2000 (has links)
Resumo: O objetivo desra pesquisa foi avaliar a microinfiltração através da microscopia óptica e a nanoinfiltração, através da Microscopia Eletrônica de Varredura (MRV), em cavidades classe V, preparadas por dois métodos: 1) irradiação à laser Er:UAG mais condicionamento ácido e 2) turbinas de alta-rotação. Foi observado também a influência da irradiação do laser Nd;YAG em dois sistemas de adesivo dentinários: Single Bond (3M) e Prime & Bond NT (Dentsply). As cavidades foram restauradas com a resina composta Z100 quando foi utilizado o adesivo... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The purpose of this study was evaluate the microleakage and nanoleakage inclass V restorations prepared with Er:YAG laser and conventionally. The influence of Nd:YAG laser irradiation in two adhesive systems was also investigated: Single Bond (3M) and Prime & Bond NT (Dentsply). The cavity were restored with composite Z100 when Single Bond was used and composite TPH... (Complete abstract click electronic access below)
|
4 |
Avaliação dos efeitos da radiação ionizante em materiais utilizados em restaurações dentárias / EVALUATION OF EFFECTS OF IONIZING RADIATION ON MATERIALS USER IN DENTAL RESTORATIONS.Maio, Miréia Florencio 14 May 2009 (has links)
O trabalho consistiu na realização de estudos quantitativos dos efeitos provocados pela radiação ionizante sobre os materiais utilizados em restaurações dentárias (Titânio, Amálgama, Resina Composta e Ionômero de Vidro), visando amenizar os possíveis efeitos deletérios quando da radioterapia em pacientes portadores de tumores de cabeça e pescoço, observados quando a dentição restaurada está compreendida no campo de radiação. Corpos de provas foram submetidos a feixes de radiação-X de 6 MV provenientes de um acelerador linear, marca VARIAN modelo 2100C, comumente utilizados nos tratamentos de cânceres da região da cabeça e pescoço, e disponíveis no Serviço de Radioterapia da Faculdade de Medicina de Botucatu. As amostras foram analisadas por técnica de fluorescência de raios-X comparando a composição química antes e depois da irradiação. Foram realizadas medidas de dosimetria das amostras com detectores de radiação do tipo Geiger-Müller e câmara de ionização a fim de se verificar a radiação residual nas amostras. As amostras também foram analisadas por espectrometria gama com detector de Germânio Hiper puro (HPGe). Com estas análises, pretendeu-se verificar pequenas alterações nas composições dos corpos de prova devido à interação da radiação. Os resultados deste estudo poderão incentivar a realização de pesquisas de novas alternativas de materiais utilizados em restaurações dentárias que possam contribuir para melhoria da qualidade de vida daqueles pacientes portadores de tumores da boca. / This work consisted of quantitative studies of the effects caused by ionizing radiation on materials used in dental restorations (Titanium, Amalgam, Resin Composite and Glass Ionomer) aiming the deleterious effects of radiotherapy when patients with tumors in head and neck, arising when the teeth are restored within in the field of radiation. Samples were submitted to X-ray beams of 6 MV from a linear accelerator, VARIAN 2100C model. The samples were analyzed by X-ray fluorescence techniques to compare the chemical composition before and after the irradiation. The sample were submitted to Geiger-Müller detectors and the ionization chambers in order to verify any residual radiation in the samples. The samples were also analyzed by gamma spectrometry by a Germanium detector. These tests were performed to determine small changes in the composition in the samples due to the radiation interaction. The results of this study may encourage the development of new research for alternative materials in dental restorations that can contribute to improve the quality of life of those patients with tumors of the mouth.
|
5 |
Avaliação dos efeitos da radiação ionizante em materiais utilizados em restaurações dentárias / EVALUATION OF EFFECTS OF IONIZING RADIATION ON MATERIALS USER IN DENTAL RESTORATIONS.Miréia Florencio Maio 14 May 2009 (has links)
O trabalho consistiu na realização de estudos quantitativos dos efeitos provocados pela radiação ionizante sobre os materiais utilizados em restaurações dentárias (Titânio, Amálgama, Resina Composta e Ionômero de Vidro), visando amenizar os possíveis efeitos deletérios quando da radioterapia em pacientes portadores de tumores de cabeça e pescoço, observados quando a dentição restaurada está compreendida no campo de radiação. Corpos de provas foram submetidos a feixes de radiação-X de 6 MV provenientes de um acelerador linear, marca VARIAN modelo 2100C, comumente utilizados nos tratamentos de cânceres da região da cabeça e pescoço, e disponíveis no Serviço de Radioterapia da Faculdade de Medicina de Botucatu. As amostras foram analisadas por técnica de fluorescência de raios-X comparando a composição química antes e depois da irradiação. Foram realizadas medidas de dosimetria das amostras com detectores de radiação do tipo Geiger-Müller e câmara de ionização a fim de se verificar a radiação residual nas amostras. As amostras também foram analisadas por espectrometria gama com detector de Germânio Hiper puro (HPGe). Com estas análises, pretendeu-se verificar pequenas alterações nas composições dos corpos de prova devido à interação da radiação. Os resultados deste estudo poderão incentivar a realização de pesquisas de novas alternativas de materiais utilizados em restaurações dentárias que possam contribuir para melhoria da qualidade de vida daqueles pacientes portadores de tumores da boca. / This work consisted of quantitative studies of the effects caused by ionizing radiation on materials used in dental restorations (Titanium, Amalgam, Resin Composite and Glass Ionomer) aiming the deleterious effects of radiotherapy when patients with tumors in head and neck, arising when the teeth are restored within in the field of radiation. Samples were submitted to X-ray beams of 6 MV from a linear accelerator, VARIAN 2100C model. The samples were analyzed by X-ray fluorescence techniques to compare the chemical composition before and after the irradiation. The sample were submitted to Geiger-Müller detectors and the ionization chambers in order to verify any residual radiation in the samples. The samples were also analyzed by gamma spectrometry by a Germanium detector. These tests were performed to determine small changes in the composition in the samples due to the radiation interaction. The results of this study may encourage the development of new research for alternative materials in dental restorations that can contribute to improve the quality of life of those patients with tumors of the mouth.
|
6 |
Determinantes ao longo do ciclo vital para a escolha de material e falha de restaurações em dentes posteriores em adultos jovens: um estudo numa coorte de nascimentos / Determinants across the life cycle to choice of material and failure of restorations in posterior teeth in young adults: a study in a birth cohort in 2011Corrêa, Marcos Britto 02 December 2011 (has links)
Made available in DSpace on 2014-08-20T14:30:12Z (GMT). No. of bitstreams: 0
Previous issue date: 2011-12-02 / Resin composites have become the first choice for direct posterior restorations and are increasingly popular among clinicians and patients in comparision to amalgam. When evaluating direct restorations, generally clinical variables and characteristics related to materials and operators have been focused. On the other hand, studies investigating the influence of factors related to patients are very rare and most of them were carried out in university clinical settings, with a lack of population-based data. This study aimed to evaluate posterior restorations placed in young adults, investigating the association between determinants experienced during the life course and two posterior restorations outcomes: the quality of tooth fillings and the dentists choice of restorative material. In addition, we reviewed the dental literature looking for clinical trials investigating posterior composite restorations over periods of at least 5 years of follow-up published between 1996 and 2011 to investigate the longevity of composite restorations in this studies and factors that influence restorations failures.A representative sample (n = 720) of all 5,914 births occurring in Pelotas in 1982 were prospectively investigated, and posterior restorations were assessed at 24 yr-old. Exploratory variables included demographic and socioeconomic, oral health and service utilization patterns during the lifecourse. Tooth related variables (type of tooth, material, size of cavity) were also analysed. Multilevel Logistic Regression models were used to determine factors associated with restoration outcomes. Failures in posterior restorations showed a significant association with socioeconomic (income trajectory from birth to age 23), clinical (presence of dental caries at age 15) and tooth-related variables (size of cavity). On the other hand, dentists choice for amalgam as posterior restorative material was associated with type of payment of dental services (health insurance vs. private), higher presence of dental caries at age 24, type of tooth (molars vs. premolars) and size of cavity. These results suggest that, although tooth-related variables have an important role in the investigated restorations outcomes, patient-related factors, such as socioeconomic and oral health variables, are also associated with these conditions and should take in account when evaluating posterior restorations / Em relação ao amálgama, as resinas compostas têm aumentado sua popularidade entre dentistas e pacientes tornando-se os materiais de primeira escolha para restaurações diretas em dentes posteriores. Ao avaliar estas restaurações, geralmente variáveis clínicas e relativas aos materiais e profissionais têm sido investigadas. Por outro lado, estudos investigando os fatores relacionados aos pacientes são raros, sendo a maioria deles realizados em ambientes clínicos universitários, com uma carência de dados de base populacional. Este trabalho tem por objetivo avaliar as restaurações em dentes posteriores realizadas em adultos jovens, investigando a associação entre determinantes experimentados ao longo da vida dos indivíduos e dois desfechos relacionados as mesmas: a qualidade das restaurações e; a escolha dos dentistas pelo material restaurador.Ainda, uma revisão de literatura, incluindo estudos longitudinais com mais de cinco anos de observação foi
realizada com o objetivo de investigar a longevidade das restaurações de resina composta e os fatores que determinam a mesma. Uma amostra representativa (n = 720) de todos os 5914 nascimentos ocorridos em Pelotas, RS, em 1982 foi investigada prospectivamente, e as restaurações posteriores foram avaliadas em 2006, aos 24 anos de idade. As variáveis de exposição incluíram características demográficas, socioeconômicas, de saúde bucal e de utilização de serviços ao longo da vida. Variáveis relativas ao dente (tipo, material restaurador, tamanho da cavidade) também foram analisadas.Modelos de análise de Regressão Logística Multinível foram utilizados para determinar os fatores associados com os desfechos avaliados. Falhas em restaurações posteriores foram associadas significantemente com a pior trajetória socioeconômica do nascimento aos 23 anos, com a maior presença de cárie aos 15 anos e com o maior tamanho da cavidade. Por outro lado, a escolha de amálgama como material restaurador pelos dentistas esteve associada ao tipo de pagamento de serviços odontológicos (convênio versus particular), à maior presença de cárie dentária aos 24 anos, ao tipo de dente (molar versus pré-molar) e ao maior tamanho de cavidade. Os resultados sugerem que, embora as variáveis relativas ao dente desempenhem um papel importante nos desfechos avaliados, fatores relacionados aos pacientes, como características socioeconômicas e de saúde bucal também estão associadas a estas condições, devendo ser levadas em consideração na avaliação de restaurações em dentes posteriores.
|
Page generated in 0.096 seconds