Spelling suggestions: "subject:"rugosidade"" "subject:"rugosidades""
11 |
Metodologia analítica para o modelo de corrosão : crescimento e rugosidadeAlves, Washington Soares 24 June 2014 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade UnB Planaltina, Programa de Pós-Graduação em Ciência de Materiais, 2014. / Submitted by Ana Cristina Barbosa da Silva (annabds@hotmail.com) on 2014-10-14T12:03:45Z
No. of bitstreams: 1
2014_WashingtonSoaresAlves.pdf: 2423938 bytes, checksum: a691cc763d8782653ab60b65315864e0 (MD5) / Approved for entry into archive by Raquel Viana(raquelviana@bce.unb.br) on 2014-10-22T14:17:19Z (GMT) No. of bitstreams: 1
2014_WashingtonSoaresAlves.pdf: 2423938 bytes, checksum: a691cc763d8782653ab60b65315864e0 (MD5) / Made available in DSpace on 2014-10-22T14:17:19Z (GMT). No. of bitstreams: 1
2014_WashingtonSoaresAlves.pdf: 2423938 bytes, checksum: a691cc763d8782653ab60b65315864e0 (MD5) / Na presente dissertação, desenvolvemos uma metodologia analítica para obter a função matemática da rugosidade e os expoentes críticos (rugosidade - α, crescimento- β e dinâmico - z) de modelos de crescimento superficial baseado em autômatos celulares. A metodologia é geral e pode ser utilizada em qualquer modelo que envolva interação entre primeiros vizinhos e que seja unidimensional. O desenvolvimento dessa metodologia se baseia nas probabilidades de ocorrência das configurações superficiais e como elas infuenciam a variação da rugosidade. Para isto utilizamos diversas ferramentas matemáticas, como o estudo das superfícies das hiperesferas, função gama e fatorial. Para verificarmos a validade de nossa metodologia, escolhemos analisar o modelo de corrosão (etching model) proposto por Mello, Chaves e Oliveira [1]. Este modelo descreve a evolução da corrosão em uma superfície sob a ação de um fuido corrosivo. Após empregarmos a nossa metodologia no modelo de corrosão, obtivemos uma equação matemática implícita da evolução da rugosidade e os expoentes críticos com boas aproximações dos valores obtidos por Mello et al em seu artigo original. _______________________________________________________________________________________ ABSTRACT / In this monograph, we develop an analytical methodology for obtaining the mathematical function of the roughness and the critical exponents (roughness - α, growth - β and dynamic - z) of surface growth models based on cellular utomata. The method is general and can be used in any one-dimensional model involving interaction between nearest neighbors. The development of this methodology is based on the probabilities of occurrence of surface con_gurations and how they inuence the roughness. We use various mathematical tools, such as the study of the surfaces of hyperspheres, gamma and factorial functions. To check the validity of our methodology, we chose to analyze the etching model proposed by Mello, Chaves and Oliveira [1]. This model describes the evolution of corrosion on surface under the action of a corrosive uid. After we use our methodology in the etching model, we obtained an implicit mathematical equation of roughness and the critical exponents with good approximations of the values obtained by Mello et al in their original article.
|
12 |
Classes de universalidade na equação de Edwards-Wilkinson com memóriaAlmeida, Diogo Pereira 24 July 2014 (has links)
Dissertação (mestrado)–Universidade de Brasília, Faculdade UnB de Planaltina, Mestrado em Ciências de Materiais, 2014. / Submitted by Ana Cristina Barbosa da Silva (annabds@hotmail.com) on 2014-11-26T16:49:25Z
No. of bitstreams: 1
2014_DiogoPereiraAlmeida.pdf: 681751 bytes, checksum: 5cac10b5ea3f91c1bfbf429a9e95e60d (MD5) / Approved for entry into archive by Patrícia Nunes da Silva(patricia@bce.unb.br) on 2014-11-27T18:00:16Z (GMT) No. of bitstreams: 1
2014_DiogoPereiraAlmeida.pdf: 681751 bytes, checksum: 5cac10b5ea3f91c1bfbf429a9e95e60d (MD5) / Made available in DSpace on 2014-11-27T18:00:16Z (GMT). No. of bitstreams: 1
2014_DiogoPereiraAlmeida.pdf: 681751 bytes, checksum: 5cac10b5ea3f91c1bfbf429a9e95e60d (MD5) / No presente trabalho, apresentamos um estudo da equação de Edwards-Wilkinson (EEW) que é uma equação de crescimento linear e estocástica [1]. Apresentamos uma metodologia de resolução da EEW mais simples do que a resolução apresentada no trabalho clássico de Nattermann [2]. Propusemos uma generalização da EEW para incluir os casos de crescimento com memória, ou seja, crescimentos cujas variações de altura sofrem influências explícitas de informações do passado. Denominamos esta nova equação de Edwards-Wilkinson com memória (EEWM). Em seguida, estudamos como diversas funções memórias repercutem nos expoentes críticos de crescimento. Obtivemos também uma resolução analítica que descreve a evolução da rugosidade para a EEWM e utilizando esta equação da rugosidade, analisamos outras funções memórias e como elas possibilitam um mudança de suas classes de universalidade. _________________________________________________________________________________ ABSTRACT / In this work we study the Edwards-Wilkinson equation (EWE) for growth[1]. The EWE is a linear equation which contains difusion and stochasticnoise. We present a methodology for solve the EWE which is simpler than that presented in the classical work of Nattermann [2]. We propose a generalization of the EWE to include the so-called memory. I.e. a growth dynamics where remote events of the past are important to dynamic events in the present time. We call this new equation the Edwards-Wilkinson equation with memory (EWEM). We investigate how the memories can change the critical growth exponents. Moreover, we obtain an analytical solution to describe the roughness evolution, and to determine how memories change the exponentsand its universality class.
|
13 |
"Estudo in vitro do efeito de três diferentes agentes clareadores sobre a dureza e rugosidade do esmalte dentário bovino"Heraldo Riehl 15 April 2002 (has links)
Foi avaliada a influência de três tipos distintos de agentes clareadores sobre a rugosidade e a dureza Vickers do esmalte bovino. Quarenta incisivos centrais inferiores foram divididos em quatro grupos: 1o.) água deionizada (controle); 2o.) peróxido de hidrogênio a 35%; 3o.) palescence X-tra e 4o.) Opalescence Regular a 10%. Os ensaios foram executados antes e depois dos tratamentos. As médias iniciais e finais obtidas de rugosidade (expressos em micrometros) foram, respectivamente, de 58,4 e 58,9 para os dentes do grupo 1, de 62,9 e 399,6 para os do 2, de 60,5 e 282,1 para os do 3 e de 56,4 e 58,5 para os do 4; quanto à dureza (expressos em números puros) foram, respectivamente, de 259,2 e 258,9 para os do grupo 1, de 256,7 e 172,8 para os do 2, de 259,7 e 213,1 para os do 3 e de 260,3 e 259,4 para os do 4. Foi estatisticamente constatado que os espécimes dos grupos 2 e 3 mostraram alterações nas propriedades estudadas; consequentemente, receberam um tratamento adicional, denominado ameloplastia com ácido (através de uma aplicação do produto Opalustre), o qual permitiu a recuperação dos valores originais, para ambas as propriedades referidas. / The influence of 3 whitenning agents upon rugosity and Vickers hardness of bovine dental enamel was evaluated. It were used 40 lower central incisives, divided into 4 groups: 1st) deionized water, 2nd) 35% hidrogen peroxide, 3rd) Opalescence X-tra and 4th) Opalescence Regular 10%. Essays were performed before and after treatments. The inicial and final average values to rugosity (im micrometers) were respectively 58,4 and 58,9 to the teeth from the first group, 62,9 and 399,6 to these of the second, 60,5 and 282,1 to these of the third and 56,4 and 58,5 to these of the fourth; to the hardness (as pure numbers) they were respectively 259,2 and 258,9 to the teeth of the first group, 256,7 and 172,8 to these of the second, 259,7 and 213,1 to these of the third and 260,3 and 259,4 to these of the fourth. It was statiscally detected changes in the specimens of groups 2 and 3; due to this, an adittional treatment, named ameloplasty with acid, promoted a recuperation of original values, to both the studied characteristics.
|
14 |
Avaliação do desgaste e da alteração da rugosidade superficial em resinas compostas de diferentes características submetidas à escovação simulada e ciclagem de pH / Wear and surface roughness alteration evaluation of different composite resins after toothbrushing and pH cyclingGabriela Ulian de Oliveira 29 August 2011 (has links)
O presente estudo teve como objetivo avaliar quantitativamente a alteração na rugosidade superficial e o desgaste de resinas compostas com diferentes características de matriz orgânica e de carga inorgânica frente ao teste de escovação simulada e ciclagem de pH. Foram testadas três resinas compostas: Filtek Z250 (Bis-GMA, microhíbrida), Filtek Z350 (Bis-GMA, nanoparticulada) e Filtek P90 (silorano, microhíbrida)(3M-ESPE). Para cada resina foram confeccionados dois grupos (n=10) de corpos de prova retangulares (15mmx5mmx4mm). Após a polimerização e polimento adequado dos espécimes, a rugosidade inicial (Ra) foi obtida pela média de três leituras com o Rugosímetro Hommel T1000. Metade de cada corpo de prova foi protegida com esmalte de unha e um dos grupos de cada resina foi submetido a um protocolo de ciclagem de pH (desmineralização-pH 4,3 e remineralização-pH 7,0). Para o teste de abrasão foram realizados 100.000 ciclos de escovação simulada, permanecendo a metade protegida como grupo controle. Na metade escovada foi verificada a rugosidade final, seguindo os mesmos parâmetros iniciais, e o desgaste (µm) foi quantificado pela média de 3 leituras do perfil real abrangendo as duas superfícies (controle e escovada). Os resultados obtidos (ANOVA, teste t Student e Tukey, p<0.05) mostraram diferenças significantes para o desgaste e alteração de rugosidade entre as resinas testadas. A maior média de desgaste foi apresentada pela Filtek P90 (11,505µm±5,690) com diferença significante para a Filtek Z250 (4,191µm±1,725) e para a Filtek Z350 (4,163µm±0,947), sendo que a ciclagem de pH afetou apenas o desgaste da resina Filtek P90 (15,305µm±5,409). Verificou-se aumento da média de rugosidade superficial para as resinas Filtek Z250 e Z350 após escovação simulada, enquanto que a resina Filtek P90 apresentou comportamento contrário, com diferenças estatisticamente significantes (p<0,05). As imagens de microscopia eletrônica de varredura apresentaram-se coerentes com os resultados quantitativos obtidos. / The present study aimed to quantitatively evaluate the surface roughness alteration and wear of resin composites with different characteristics of organic matrix and inorganic filler when submitted to simulated toothbrushing abrasion and pH cycling. Three different resin composites were evaluated: Filtek Z250 (Bis-GMA, microhybrid), Filtek Z350 (Bis-GMA, nanofilled) and Filtek P90 (silorane based, microhybrid) (3M-ESPE). For each resin two groups (n=10) of rectangular specimens (15mmX5mmX4mm) were made. After polymerization and polishing, the initial roughness (Ra) was evaluated by the average of three tracings using a roughness tester Hommel T1000 basic. Half of each specimen was protect with nail varnish and one group of each resin was submitted to pH cycling (demineralization-pH 4,3 and remineralization-pH 7,0). For the abrasion test 100.000 strokes of simulated toothbrushing was processed. The protected side was maintained as control. Over the brushed side the final roughness was measured with the same initial parameters and wear was quantified by the average of 3 readings of the real profile between the two surfaces (control and brushed side). The obtained results (ANOVA, Student t test and Tukey, p<0.05) showed significant differences of wear and surface roughness alteration between the tested materials. Filtek P90 presented the highest average wear rate (11.505 ± 5.690µm) compared to Z250 (4.191 ± 1.725µm) and Z350 (4.163 ± 0.947µm) and the pH cycling significantly affected the wear of Filtek P90(15.305 ± 5.409 mM). The surface roughness evaluation revealed an increasing on surface roughness for Filtek Z250 and Filtek Z350 after toothbrushing, while Filtek P90 showed an opposite behavior, with statistically significant differences (p<0.05). The scanning electron microscope images were in accordance to the quantitative results obtained.
|
15 |
Avaliação do Desgaste e Rugosidade Superficial de Materiais Utilizados para Selante, Submetidos à Escovação com Dois Diferentes Dentifrícios / WEAR AND SUPERFICIAL ROUGHNESS OF MATERIALS USED AS FISSURES SEALANTS, SUBMITTED TO TOOTHBRUSHING TEST WITH TWO DIFFERENTS DENTIFRICESDaniela Rios 28 August 2000 (has links)
O presente estudo foi conduzido in vitro com o intuito de constatar algumas das propriedades (desgaste e rugosidade) dos CIV (cimento de ionômero de vidro), as quais influenciam na sua indicação como material selador de fossas e fissuras. Simultaneamente avaliaram-se a abrasividade de dois dentifrícios (Tandy e Sorriso) e a influência destes sobre a lisura de superfície dos selantes. Os materiais empregados foram Fuji Plus (CIV cimentante), Ketac-Molar e Vitremer (ambos CIV restauradores). Este último material foi utilizado em duas proporções: na recomendada pelo fabricante (1:1) e na forma experimentalmente diluída (1/4:1). O selante resinoso Delton, sem carga e quimicamente ativado, foi utilizado como controle. A determinação do desgaste foi obtida através da quantidade de massa perdida após a escovação, utilizando-se uma balança eletrônica de precisão, em grupos de 12 corpos de prova de cada material com ambos dentifrícios. A rugosidade foi determinada pela análise quantitativa da superfície destes corpos de prova através de um aparelho medidor (rugosímetro), comparando a diferença de rugosidade após os testes de escovação. Os resultados foram submetidos à análise de variância a dois critérios e ao teste de Tukey (p<0.05). A abrasividade do dentifrício Tandy foi semelhante à do Sorriso nos cinco grupos de materiais testados, sendo Vitremer diluído e Fuji Plus os que possuíram o maior grau de desgaste. A rugosidade resultante da escovação com o dentifrício Sorriso nos grupos Vitremer diluído e Fuji Plus, foi maior comparada ao Tandy enquanto nos outros grupos a ação dos dentifrícios foi semelhante. O material que apresentou maior aumento de rugosidade foi o Vitremer diluído, os outros apresentaram resultados estatisticamente equivalentes, com exceção do Fuji Plus, que mostrou a segunda maior rugosidade quando submetido ao dentifrício Sorriso. Apesar de clinicamente se encontrar um maior uso dos cimentos ionoméricos cimentantes ou diluídos como forma alternativa para material selador; este trabalho permitiu concluir que in vitro estes possuem propriedades bastante inferiores quando comparados aos ionômeros restauradores que, por sua vez, possuem resultados semelhantes ao selante resinoso utilizado como controle. / The purpose of this study was to evaluate, in vitro, some properties (wear and roughness) of glass ionomers ciment that could influence its indication as pit and fissures sealants. Simultaneously it was evaluated the abrasion of two dentifrices (Tandy and Sorriso) and its influence on the roughness surface. The materials used were Fuji Plus (luting cement), Ketac-molar and Vitremer (both restorative cements). This last material was prepared in two proportions: one in accordance with the manufacturers instructions (1:1) and the other in a diluted form (1/4:1). The resin-based sealant, Delton, chemically activated, was used as control. Using an electronic analytical balance, wear was measured by the level of loss weight, in 12 specimens groups for each material and for each dentifrice, after submitting then to the toothbrushing test. The superficial roughness was determined by a quantitative analysis of the specimens surface, after toothbrushing test, using a rugometer apparatus. The results were analyzed by the two-ways ANOVA criterion and the Tukey test at p <0.05. The two dentifrices abrasivity were similar for the five groups tested. Compared with the other materials, diluted Vitremer and Fuji Plus resisted less to tooth brushing abrasion. The resulting roughness in the diluted Vitremer and Fuji Plus groups, tooth brushed with Sorriso, were greater as compared to Tandy, while in the other groups the action of the dentifrices were similar. The material that had the most increase on superficial roughness was diluted Vitremer, the others presented estatistical equivalent results, except for Fuji Plus, that showed the second greatest roughness when submitted to dentifrice Sorriso. Though In clinical situations the material often used as an alternative for resin-based sealants are the luting or diluted cements, the results of the study in vitro showed that these kind of cements have worse properties than the restorative ionomers which revealed similar results when compared to the evaluated resin sealant.
|
16 |
Levantamento em campo da rugosidade equivalente de tubos metálicos / Field survey of the equivalent roughness of mettalic pipesSchroder, Francisco Carlos, 1960- 19 August 2018 (has links)
Orientador: Paulo Vatavuk / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-19T08:44:36Z (GMT). No. of bitstreams: 1
Schroder_FranciscoCarlos_M.pdf: 3459488 bytes, checksum: a1a920f7c561f9c61836a4366dc4a636 (MD5)
Previous issue date: 2011 / Resumo: O objetivo deste trabalho é pesquisar e esclarecer as divergências dos valores de rugosidade equivalente de tubos comerciais de diferentes materiais, notadamente os de aço e ferro, que são mais comuns em aplicações industriais e de saneamento, no transporte de líquidos. Como estes valores muitas vezes não são coincidentes, apesar de originarem de materiais e processos similares, geram dúvidas quando de sua escolha para formulação do fator de atrito, que é utilizado para o cálculo de perdas de carga distribuídas em sistemas de bombeamento. O trabalho propõe recomendações para melhorar a estimativa da rugosidade em tubos metálicos rugosos, baseado em casos reais de dimensionamento de perdas por atrito em projetos de bombeamento de água / Abstract: The objective of this study is to investigate and to clarify the differences in the values of equivalent roughness of commercial pipes of different materials especially the steel and iron pipes that are more common in industrial and sanitation applications for transport of liquids. Since these values do not coincide despite similar of materials and processes inaccuracy in the formulation of the friction factor can occur, they create doubts when comes the choice for the formulation of the friction factor, which is used to calculate pressure drops distributed in pumping systems. This work proposes recommendations for improving the estimate of roughness in metallic tubes based on real cases rough sizing of friction loss in water pumping projects / Mestrado / Recursos Hidricos, Energeticos e Ambientais / Mestre em Engenharia Civil
|
17 |
Resinas compostas avaliadas in vitro em relação à rugosidade superficial e à infiltração marginalCAVALCANTI, Raquel Braz 31 January 2008 (has links)
Made available in DSpace on 2014-06-12T22:56:45Z (GMT). No. of bitstreams: 2
arquivo3981_1.pdf: 1557532 bytes, checksum: 7d92761bb0a7ee03c215665a7e13cd01 (MD5)
license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5)
Previous issue date: 2008 / Avaliaram-se a rugosidade superficial e a microinfiltração em restaurações classe V realizadas com as resinas: Filtek Z350 (3M ESPE) e TPH®3 (Dentsply). Utilizaram-se vinte pré-molares superiores humanos extraídos, obtendo-se quatro grupos. Grupo 1: restaurações vestibulares com Filtek Z350; grupo 2: restaurações palatinas com TPH®3 grupo 3: restaurações vestibulares com Filtek Z350 e grupo 4: restaurações palatinas com TPH®3; para os grupos 1 e 2 as restaurações foram finalizadas com tira de poliéster, e as restaurações dos grupos 3 e 4 foram submetidas à seqüência acabamento e polimento estabelecida. A rugosidade superficial das restaurações foi avaliada com o rugosímetro Mitutoyo modelo Surftest SJ400. Obteve-se a média da rugosidade em cada grupo e não houve diferença significativa, estatisticamente (média, desvio padrão e teste estatístico), para ambas as resinas. Posteriormente, os elementos foram analisados quanto à microinfiltração. Atribuíram-se escores de acordo com o grau de penetração do corante em grau 0, 1 2 e 3. A maioria das avaliações (69,2%) foram atribuídas ao grau 0, seguido de 27,5% para o grau 1. O percentual de avaliações atribuído para o grau 0 foi mais elevado nos grupos 2 (86,7%) e 1 (83,3%) e o menor percentual (43,3%) registrado no grupo 3. Quando se utilizou a tira de poliéster, as duas resinas obtiveram um menor índice de infiltração. Quando realizada a seqüência de acabamento e polimento adotada, a resina Filtek Z350 apresentou, em média, maior rugosidade e maior percentual de infiltração em comparação a TPH®3.
Significância Clínica: As resinas compostas avaliadas in vitro, em relação à rugosidade superficial, não demonstraram diferenças estatísticas significativas quando finalizadas com tira de poliéster ou quando submetidas à sequência de acabamento e polimento adotadas. Quanto à infiltração marginal, a maioria apresentou ausência, independente do tipo de resina e técnica de acabamento /polimento
|
18 |
Efeito de agentes clareadores na rugosidade superficial de resina composta de partículas microhíbridasLEMOS, Natalia Rabelo de Carvalho 31 January 2010 (has links)
Made available in DSpace on 2014-06-12T23:01:52Z (GMT). No. of bitstreams: 2
arquivo957_1.pdf: 985275 bytes, checksum: 3726a70c869f4a1c4f07b1226cc51aed (MD5)
license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5)
Previous issue date: 2010 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / Esta dissertação foi realizada em formato de artigo, de acordo com as normas do Programa de Pós-Graduação em Odontologia da Universidade Federal de Pernambuco. O objetivo deste estudo foi avaliar a influência que os agentes clareadores exercem sobre a rugosidade superficial (Ra) da resina composta micro-híbrida (Z250 3M ESPE). Os resultados foram: houve diferença estatística no G9 antes e após o tratamento clareador; e entre os grupos que utilizaram o peróxido de carbamida 16%, quando comparado o fator tempo. Conclui-se que os agentes clareadores não provocam alteração significante na rugosidade superficial da resina composta, independente do agente, do tempo e da concentração
|
19 |
Influência do acabamento e polimento na rugosidade de uma porcelana odontológicaRafael Dario Werneck 21 August 2007 (has links)
Nas últimas três décadas houve incremento da exigência estética na área odontológica, provocado pela crescente valorização da apresentação pessoal, acompanhada do grande avanço tecnológico dos materiais em suas propriedades físicas e biológicas, o que proporcionou uma utilização clínica cada vez maior. Dentre esses materiais destacam-se as porcelanas odontológicas que vem apresentando excelentes resultados estéticos, sendo empregadas em diferentes situações clinicas.
Durante a confecção de restaurações parciais tipo inlay e onlay com porcelanas feldspáticas, o clinico se depara com certos obstáculos. Um deles é o ajuste oclusal da peça protética que, nessas situações, deve ser realizado apenas após a cimentação definitiva, para evitar fraturas ou trincas. Com isso perde-se em algumas regiões o glaze, previamente realizado pelo técnico de laboratório. Isto pode acarretar alterações em sua estrutura com conseqüente aparecimento de trincas, perda de caracterização superficial, redução da resistência, geração de maior tensão durante contatos oclusais e alteração da sua rugosidade superficial. Esta última influenciará decisivamente na aderência bacteriana, acúmulo de biofilme dental, grau de desgaste do elemento antagonista e eficiência mastigatória. O trabalho avaliou in vitro a rugosidade (parâmetro Ra) de uma porcelana feldspática modificada glazeada e submetida a dois sistemas de acabamento e polimento. Os resultados não mostraram diferença estatisticamente significante entre os grupos e a superfície glazeada (P<0,05). / In the last three decades it had an increment of the aesthetic requirement in dentistry area, which became from the increasing valuation of the personal presentation, followed by the great technological advance of the materials in its physical and biological properties, which provided more clinical utilities over the time. Among these materials, the dental porcelains are showing excellent aesthetic results and they are used in different clinical practice situations. During the confection of partial restorations, like feldspathic inlay and onlay, the dentist comes across with certain obstacles. One of them it is the oclusal adjustment of the prosthetic restoration, which on these situations must be done through after the cimentation, to prevent fracture or crack lines. Therefore the glaze is lost in some regions, previously executed by the lab technician. It will be able to cause alterations in its structure and then it will show
up same cracks, loss of superficial characterizations, reduction of the resistance, appearence of tension during oclusals contacts and alteration of its surface roughness. The last refer will influence decisively in the bacterial aderance, dental accumulation of biofilm, waste levels of antagonist surface and mastigatory efficience. The present study evaluated in vitro the roughness (Ra parameter) of the modified feldspathic porcelain glazed and submitted to two systems of finishing and intrabucal polishing. The results had not shown estatisticlly significant difference between the tests groups and the control glazing surface group(P<0,05).
|
20 |
Avaliação da alteração de cor e rugosidade utilizando diferentes sistemas adesivos e selantes de superfície sobre a resina composta / Evaluation of the color change and roughness of different adhesive systems and surface sealants on the composite resinCortopassi, Lucas dos Santos 11 March 2019 (has links)
O objetivo deste trabalho foi avaliar diferentes materiais de cobertura (sistemas adesivos e selantes de superfície) quanto à alteração de cor e rugosidade quando aplicados sobre a superfície da resina composta. Noventa corpos de prova foram confeccionados em resina composta Z350 XT, A2E (3M Oral Care) com o auxílio de molde em Teflon (5x5x3mm). Após sua confecção, os corpos de prova foram imersos e mantidos em água deionizada durante 24h em estufa a 370C. Em seguida, os corpos de prova foram polidos, lavados em cuba ultrassônica e então distribuídos aleatoriamente nos grupos experimentais (n=10): 1) CTRL - somente polimento ; 2) SB - Adper SingleBond II (3M Oral Care); 3) US - Single Bond Universal (3M Oral Care); 4) CF - Clearfil SE (Kuraray); 5) APS - Ambar APS (FGM); 6) BF - Bioforty (Biodinâmica); 7) FF - Fortify (Bisco); 8) PS - PermaSeal (Ultradent); 9) GC - G CoatPlus (GC). Os corpos de prova foram avaliados quanto à alteração de cor em um Espectrofotômetro e quanto à rugosidade em um Perfilômetro óptico. Após as leituras iniciais, os corpos de prova foram imersos em vinho tinto e as medidas de ?E (alterac?a?o de cor) e Ra (rugosidade) foram analisadas nos tempos 24h, 72h e 168h. Os dados foram submetidos à análise de variância (ANOVA), testes de Tukey e teste de correlação de Pearson (p< 0,05). Não houve estabilidade de cor em nenhum dos grupos experimentais, inclusive no controle. Os selantes de superfície: BF, FF e PS e o sistema adesivo SB apresentaram a menor alteração em 24h e semelhante ao CTRL. O sistema adesivo APS apresentou a maior alteração de ?E em todos os tempos testados e diferença estatística em relação aos demais grupos (p<0,05). Em até 72h a alteração de cor ocorreu em maior intensidade, com tendência estabilizar-se em 168h para todos os grupos experimentais. Na aplicação imediata, os selantes de superfície e o sistema adesivo APS apresentaram a maior lisura superficial. Após 168h, o selante de superfície GC apresentou o menor valor de rugosidade e todos os demais materiais apresentaram-se semelhantes ao CTRL. Não houve correlação entre alteração de cor e rugosidade. / The purpose of this work was to evaluate different surface treatments (adhesive systems and surface sealants) regarding color change and roughness when applied on the surface of the composite resin. Ninety test specimens were made of composite resin Z350 XT, A2E (3M Oral Care) with the aid of Teflon mold (5x5x3mm). After the preparation of the specimens, they were immersed and kept in deionized water for 24 hours in an oven at 37°C. Then, the specimens were polished, washed in ultrasonic bath and then distributed randomly in the experimental groups, (n=10): 1) CTRL - only the polishing procedure; 2) SB - Adper SingleBond II (3M Oral Care); 3) US - Single Bond Universal (3M Oral Care); 4) CF - Clearfil SE the \"Bond\" bottle (Kuraray); 5) APS-Amber APS (FGM); 6) BF - Bioforty (Biodynamic); 7) FF - Fortify (Bisco); 8) PS - PermaSeal (Ultradent); 9) GC - G CoatPlus (GC). The specimens were analyzed regarding color alterations with a spectrophotometer and roughness changes with an optical profilometer. After the initial readings, the specimens were immersed in red wine and the measurements of ?E (color change) and Ra (roughness) were analyzed after 24h, 72h and 168h. Data were submitted to analysis of variance (ANOVA), Tukey\'s tests and Pearson correlation tests (p<0.05). Color stability was not observed in any of the analyses groups, including the control group. The surface sealants BF, FF and PS and the adhesive system SB presented the smallest alterations in 24h and similar to the CTRL. The adhesive system APS presented the highest ?E alterations in all times tested and it was statistically different from other groups (p<0.05). Within 72h the color change occurs at higher intensity, with a tendency to stabilize in 168h for all experimental groups. In the immediate application, the surface sealants and the adhesive system APS showed the highest superficial smoothness. After 168h, the surface sealant GC presented the lowest roughness value and all the other materials behaved similarly to the CTRL. There was no correlation between color and roughness changes.
|
Page generated in 0.0494 seconds