• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 292
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 303
  • 251
  • 120
  • 98
  • 56
  • 39
  • 36
  • 35
  • 35
  • 34
  • 33
  • 27
  • 27
  • 26
  • 23
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Polimento de rochas ornamentais: um enfoque tribológico ao processo / Dimension stones polishing: a tribological approach

Leonardo Luiz Lyrio da Silveira 02 August 2007 (has links)
Este trabalho apresenta uma contribuição experimental cujo objetivo é fornecer elementos para o aprimoramento tecnológico das etapas de polimento de rochas ornamentais. Alguns aspectos da tribologia, ramo do conhecimento amplamente utilizado nas engenharias mecânica e de materiais, foram transferidos para o estudo do polimento de rochas ornamentais e subsidiaram a investigação da interação do tribossistema composto pela rocha, pelo abrasivo e por condições operacionais. Foi desenvolvido um equipamento em laboratório que possibilitou a simulação do processo de polimento, em diversas condições operacionais, considerando as variáveis tempo, velocidade de rotação e intensidade das cargas aplicadas. Foram comparados polimentos, em condições industrial e laboratorial de rochas graníticas, visando estabelecer as influências das suas características composicionais, texturais e estruturais no processo. Os resultados permitiram definir as condições ideais para a obtenção de melhor qualidade no brilho das rochas e representa uma contribuição tanto para o entendimento do processo de polimento propriamente dito como também para a otimização do processo industrial. / This work shows an experimental contribution which goal is to provide elements to the technological improvement of each step of dimension stones polishing. Some aspects of tribology, a discipline of mechanical and material engineering, has been used on the research of dimension stones polishing and has supported the investigation of the interaction of the tribosystem composed of rock, abrasive and operational conditions. For this research, a device was developed in the lab in order to make possible the simulation of the polishing process at different operational conditions, considering the variables time, rotation speed, and intensity of the loads applied. The polishing of granite rocks at industrial and lab conditions has been compared, aiming at determining the influence of each rock characteristics such as mineral composition, texture and structure during the process. The results allowed for the definition of the ideal conditions to obtain the best quality of rock brightness and they represent a contribution to the understanding of the polishing process itself as well as provide an optimization of the industrial process.
42

Análise da superfície de porcelanatos polidos por meio de microscopia de força atômica / Porcelain stoneware tile surface analysis through atomic force microscopy

Fernandes, Mérilin Cristina dos Santos 24 May 2010 (has links)
Made available in DSpace on 2016-06-02T19:12:02Z (GMT). No. of bitstreams: 1 3197.pdf: 6315859 bytes, checksum: 36b44ae7699dfee5945b8beb022fe8eb (MD5) Previous issue date: 2010-05-24 / Financiadora de Estudos e Projetos / The porcelain stoneware tile is a ceramic product that has presented a great increase on production, since it had excellent technical properties and raised aesthetic performance. To improve its aesthetic characteristics, it is submitted to a polishing process that influences a lot of interested properties of the products, due mainly to changes observed on the superficial roughness. In this way, the roughness was investigated throughout the superficial polishing process of the glazed and unglazed (technical) porcelain stoneware tile and it was correlated with the gloss. For this, the Atomic Force Microscope (AFM) was used, being ideal to measure the roughness in nanometer scale and to visualize the nanotexture of many types of surface materials. The specular part of the gloss was measured through the equipment known as glossmeter. The results achieved shown that the technical porcelain stoneware tile in the first stage is more rough than the glazed. On the technical porcelain stoneware tile the roughness reduction was more accented between the grit 80 and 1000 stages, and the gloss was practically double between the first and the last (POLIDO) stages. The surface covering with the polymeric resin reduced significantly the product gloss, without it causes brusque alterations in superficial roughness. On the glazed porcelain stoneware tile the roughness reduction and the gloss increased occurred mainly between the grit 600 and 1800 stages. Between the grit 1800 and 8000 stages had not observed great changes on the roughness or gloss, showing that the polishing becomes unnecessary from the grit 1800. In general way, the gloss reduction occurred more visibly in stages of polishing with abrasives of larger grains, while the abrasives of smaller grains had given the final gloss, intervene poorly in roughness. The results interpretation had supplied subsidies to a better understanding and control of the process responsible for the final characteristics between the glazed and technical products, and the differences between these typologies. / O porcelanato é um produto cerâmico que apresenta grande expansão na produção, já que possui excelentes propriedades técnicas e um elevado desempenho estético. Para melhorar suas características estéticas, é submetido a um processo de polimento que influencia diversas propriedades de interesse do produto, devido principalmente às mudanças verificadas na rugosidade superficial. Desta forma, a rugosidade foi investigada ao longo do processo de polimento da superfície de porcelanatos esmaltados e não esmaltados (técnicos) e correlacionada com o brilho obtido. Para isso, foi utilizado o Microscópio de Força Atômica (AFM), ideal para medir a rugosidade em escala nanométrica e visualizar a nanotextura de muitos tipos de superfícies de materiais. A parte especular do brilho foi medida por meio do equipamento conhecido por brilhômetro. Os resultados obtidos mostraram que o porcelanato técnico no primeiro estágio analisado é mais rugoso que o esmaltado. No porcelanato técnico a diminuição da rugosidade foi mais acentuada entre os estágios de grit 80 e 1000 e o brilho do produto praticamente dobrou entre o primeiro e último estágio (POLIDO). A aplicação de resina impermeabilizante causou uma diminuição brusca do brilho, sem alterar significativamente a rugosidade. No porcelanato esmaltado a diminuição da rugosidade e o aumento do brilho ocorreram principalmente entre os estágios de grit 600 e 1800. Entre os estágios de grit 1800 e 8000 não foram observadas grandes mudanças na rugosidade, nem tampouco no brilho, mostrando que o polimento torna-se desnecessário a partir do grit 1800. De modo geral, a diminuição da rugosidade ocorreu mais visivelmente nas etapas de polimento com abrasivos de grãos maiores, enquanto os abrasivos de grãos menores deram o brilho final das peças, interferindo pouco na rugosidade. A interpretação dos resultados forneceu subsídios para um melhor entendimento e controle do processo responsável pelas características finais dos produtos esmaltados e técnicos e as diferenças entre estas duas tipologias.
43

Influência do acabamento e polimento na resistência à flexão de uma cerâmica odontológica / Influence of finishing and polishing in the flexural resistence of feldspatic ceramic

Alexandre Vicente Garcia Suarez 07 December 2007 (has links)
Avaliou-se a influência de dois sistemas de acabamento e polimento na resistência à flexão de uma cerâmica feldspática EX-3 (Noritake). Para isto, confeccionou-se blocos cerâmicos com medidas em conformidade com a ISO 6872/1995. Em seguida obteve-se o glaze natural. A padronização da rugosidade superficial foi conferida com auxílio de um rugosímetro, e os blocos foram então divididos em cinco grupos. O Grupo I (controle) foi testado com glaze. Para os testes realizados nos demais grupos, os blocos receberam um tratamento de asperização por meio de uma ponta diamantada 4137 (KG Sorensen). Em seguida foram polidos com diferentes protocolos. No grupo II, o sistema de polimento dura white (Shofu). No grupo III, o sistema de polimento dura white (shofu) associado a uma pasta diamantada aplicada com disco de feltro. No grupo IV o sistema de polimento Exa Cerapol (Edenta) e no grupo V, este mesmo sistema mais pasta diamantada aplicada com disco de feltro. Após os procedimentos de acabamento e polimento, foi avaliada a rugosidade conseguida (Ra), para se avaliar a eficácia dos métodos testados. A análise estatística por ANOVA (p ≤ 0,05) mostrou não haver diferença estatisticamente significante entre os grupos (G2=3,820,58; G3=3,550,61; G4=4,050,40; G5=3,950.47) . Feito isto, os corpos-de-prova foram submetidos a um ensaio mecânico de resistência à flexão em três pontos, e também neste caso, os resultados depois de tratados estatisticamente não demonstraram diferenças estatísticas entre os grupos glazeados e os grupos que receberam tratamento (G1=132,126,9 MPa; G2=123,317,4 MPa; G3=114,519,3 MPa; G4=104,211,9 MPa e G5=104,719,1 MPa) . Após a realização destas avaliações, tornou-se possível concluir que o uso dos sistemas de acabamento e polimento testados neste trabalho permite obter superfícies com rugosidade similar a obtida com o glaze natural e não interferem na resistência à flexão da cerâmica utilizada. / The objective of this study was to evaluate the influence of two systems of finishing and polishing in the flexural resistance of feldspatic ceramic EX-3 (Noritake). Ceramic blocks with measures in compliance with ISO 6872/1995 were confectioned following the manufacturers instructions. After the confection of the blocks and attainment of natural glaze, the standardization in terms of superficial rugosity was evaluated by means of a rugosimeter, and the blocks were then divided into five groups. One of the groups was tested in this condition (natural glaze) being Group I (control). For the tests carried through the other groups, the blocks were burnished by means of a 4137 (KG Sorensen) diamond bur. After that, they were polished with different protocols which characterized the other groups. In group II, the Dura white (Shofu) polishing system was evaluated. In group III, the same system was used, but now followed by a diamond paste in a felt wheel, In group IV, the polishing system Exa Cerapol (Edenta) was used and in the group V, this system was followed by a diamond paste in a felt wheel. After these procedures, the obtained rugosities were evaluated (Ra), in order to evaluate the effectiveness of the tested methods. The statistical analysis of ANOVA (p ≤ 0,05) showed that there were not statistical significant differences between the groups (G2=3.820.58; G3=3.550.61; G4=4.050.40; G5=3.950.47). After that, the specimen were submitted to a three points flexural strength test in a universal testing machine, and also in this case that, the statistically treated results didnt demonstrate statistical differences between the groups (G1=132.126.9 MPa; G2=123.317.4 MPa; G3=114.519.3 MPa; G4=104.211.9 MPa e G5=104.719.1 MPa). It was possible to conclude that the use of the tested systems allows to get polished surfaces similar to the natural glazed ones. and that they dont decrease the flexural resistance of the used ceramics.
44

Rugosidade em Bilhares ClÃssicos / Rugosity in Classical Billiards

JoÃo Paulo da Costa Nogueira 02 August 2016 (has links)
Conselho Nacional de Desenvolvimento CientÃfico e TecnolÃgico / Um bilhar consiste basicamente de uma partÃcula confinada em uma regiÃo do espaÃo. Trataremos apenas de bilhares em duas dimensÃes na ausÃncia de campos externos e desprezaremos qualquer tipo de forÃas dissipativas, de modo que as colisÃes da partÃcula com as fronteiras do bilhar sÃo elÃsticas. AlÃm disso, as fronteiras sÃo fixas, ou seja, respeitam uma equaÃÃo do tipo $R = R(r, heta)$, onde r e $ heta$ sÃo as coordenadas polares planas. O bilhar à um modelo interessante por vÃrios motivos. Primeiro, à um sistema muito simples (tem poucos graus de liberdade) e de fÃcil visualizaÃÃo. No entanto, possui uma dinÃmica nÃo-trivial com grande riqueza de comportamentos (podendo apresentar comportamento regular, caÃtico ou atà mesmo misto, caso em que coexistem no espaÃo de fase de um Ãnico bilhar regiÃes caÃticas e regulares). Segundo, o tratamento numÃrico desses sistemas nÃo requer integraÃÃo numÃrica de equaÃÃes diferenciais e, portanto, nÃo consume muito tempo de execuÃÃo. AlÃm disso, os bilhares permitem que realizemos investigaÃÃes de carÃter fundamental, por exemplo, podemos estudar como sistemas regulares reagem ao serem levemente perturbados. Especificamente, iremos aplicar uma rugosidade na fronteira do bilhar circular e elÃptico e observar como o espaÃo de fase irà mudar ao sofrer tal perturbaÃÃo. / In this work we are going to study a physical system known as billiard. A billiard is defined to be basically a confined particle in a closed region of the space. We are going to deal with only two-dimensionals billiards in the absence of extern fields and to neglect any kind of dissipative forces, in a way that the colisions of the particle with the boundary are elastics. Beyond that, the boundary are fixed, it means they respect an equation of kind $R(r, heta)$, where $r$ and $ heta$ are the polar coordinates on a plan. A billiard is a very interesting model by several reasons. First, it is a simple system (it has a few degree of freedom) and it is of easy visualization. However, it has a non-trivial dynamics with a big richness of behaviors (from a billiard it could appear regular behavior, chaotic behavior, or even a mixed behavior, where coexist in the phase space of one billiard chaotics and regular regions). Second, the numerical approach of these systems does not require numerical integration of diferential equations and, therefore, does not take too much time of execution. Furthermore, the billiards allow us to perform investigations of fundamental nature, for example, we can study how regular systems react by being slightly disturbed. Especificaly, we perform a rugosity perturbation on the billiard surface and observe how the phase space is going to change.
45

Efeito das superfícies cerâmicas no desgaste do esmalte dos dentes antagonistas. / The effect of glazed and polished ceramics on the wear of human enamel.

Anna Liubushka Olivera Belsuzarri 17 December 2004 (has links)
O efeito das superfícies cerâmicas no desgaste do esmalte antagonista foi estudado in vitro. Foram avaliados os desgastes produzidos pelas porcelanas glazeadas e polidas. Para tal finalidade utilizaram-se cinco cerâmicas: IPS Empress 2 (Ivoclar),IPS Empress (Ivoclar), Duceram Plus (Degussa), Duceram LFC (Degussa) e Symbio (Degussa). Oito conjuntos dente e cerâmica foram testados para cada situação, com carga padronizada e imersos em água a 37 0 C. As medidas do desgaste do esmalte e cerâmica foram avaliadas após 150000 e 300000 ciclos. Os resultados revelaram que o desgaste final do esmalte do dente antagonista foi significantemente menor quando as cerâmicas foram polidas. A quantidade do desgaste do esmalte antagonista foi maior nos primeiros 150000 ciclos. A cerâmica IPS Empress provocou um desgaste significativamente maior do esmalte do dente antagonista quando comparada com as outras cerâmicas testadas (p<0,01). As rugosidades iniciais das superfícies cerâmicas foram diferentes entre si, sendo que diminuíram após o polimento, exceto para a cerâmica IPS Empress. Não houve correlação entre a rugosidade superficial inicial das cerâmicas com o desgaste gerado no esmalte dos dentes antagonistas. / The effect of glazed and polish dental ceramic on the wear of human enamel was studied in vitro. Five ceramics: IPS Empress 2 (Ivoclar), IPS Empress (Ivoclar),Duceram Plus (Degussa), Duceram LFC (Degussa) and Symbio (Degussa), were tested in water at 37 0 C, under standard load. The amount of wear enamel and specimens was determined after 150000 and 300000 cycles. The results showed that the polished ceramics produce less amount of enamel wear. The amount of enamel wear opposite to IPS Empress ceramic was significant higher (p<0,001). The enamel wear rate increased on the first 150000 cycles. Differences between roughnesses were found in all ceramics, the roughness decreased when the ceramics were polished except for IPS Empress ceramic. No correlation on the roughness and enamel wear were found.
46

Avaliação da rugosidade superficial após o emprego de diferentes métodos de descontaminação da superfívie em discos de titânio = estudo in vitro / Evaluation of surface roughness after use different methods the decontamination on surface of titanium discs

Diefenbach, Ana Lúcia 16 August 2018 (has links)
Orientador: Márcio Zaffalon Casati / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-16T22:38:20Z (GMT). No. of bitstreams: 1 Diefenbach_AnaLucia_M.pdf: 6428742 bytes, checksum: 0c06242da8f41dfb2cd02646ac4e0208 (MD5) Previous issue date: 2010 / Resumo: Os procedimentos capazes de descontaminar a superfície implantar removendo o biofilme garantem o sucesso e a longevidade dos implantes. As conseqüências na rugosidade superficial gerada por esses procedimentos têm sido avaliadas, porém novas propostas para descontaminação das superfícies implantares vêm sendo utilizadas, principalmente para o tratamento da periimplantite. Assim, objetivo deste trabalho foi avaliar, in vitro, a rugosidade superficial de discos cilíndricos de titânio após uso de cureta plástica; jato de bicarbonato; esfregaço de tetraciclina e ultrassom piezoelétrico. Foram utilizados 50 discos de titânio com dimensões de 5 mm de altura por 5 mm de largura, com superfícies jateadas com óxido de alumínio. Os discos foram divididos aleatoriamente em cinco grupos experimentais. Grupo 1(n=10) controle - sem tratamento; grupo 2(n=10) - recebeu 15 movimentos de raspagem com cureta plástica; grupo 3(n=10) - aplicação de jato de bicarbonato por 30s a cinco milímetros da superfície; grupo 4(n=10) - aplicação de tetraciclina ácida 50mg/ml por esfregaço vigoroso por 30 segundos e grupo 5(n=10) - aplicação de 15 movimentos de raspagem por meio de ultrassom piezoelétrico com irrigação de solução polidora. Após o procedimento foram realizadas três leituras paralelas e três perpendiculares ao sentido da instrumentação utilizando rugosímetro, visando à obtenção dos valores de rugosidade superficial nos parâmetros de Ra e Rz. Os discos foram avaliados em Microscopia Eletrônica de Varredura,para a visualização da topografia superficial após os procedimentos. A análise estatística foi realizada utilizando o teste Kruskall-Wallis com um nível de significância de 5% para comparação dos valores de rugosidade superficial de cada grupo. A análise dos dados mostrou que o menor valor de rugosidade Ra foi obtido no grupo do ultrassom piezoelétrico (0.89±0.06 µm) em relação ao grupo controle (0.85±0.03 µm). O uso de tetraciclina ácida foi o tratamento que provocou maior rugosidade (0.99±0.09 µm) sendo estatisticamente diferente do grupo controle (p_0,05). Em relação ao parâmetro Rz, os resultados mostraram que o esfregaço de tetraciclina e a cureta plástica obtiveram os maiores valores de Rz (8.37±0.76 µm e 8.49±0.74µm; respectivamente) estatísticamente diferentes ao grupo controle (7.33±0.34 µm) com significância de 5%. Além disso, o uso do ultrassom piezoelétrico (7.85±0.69 µm), nos valores de Rz, não promoveu uma alteração significativa na superfície de forma a ser estatisticamente diferente do grupo controle. O estudo conclui que uso do ultrassom piezoelétrico não promoveu aumento significativo da rugosidade superficial dos discos de titânio nos parâmetros de Ra e Rz e que o jato de bicarbonato obteve valores estatísticamente semelhantes aos grupos 1, 2,4 e 5 nos dois parâmetros avaliados. O grupo da cureta plástica e esfregaço de tetraciclina ácida geraram valores estatísticamente superiores em relação ao controle e ultrassom piezoelétrico no parâmetro Rz. Todos os grupos apresentaram visualmente, a partir das fotos em microscopia eletrônica de varredura, alterações em sua superfície / Abstract: Procedures able to decontaminate the implant surface decreasing biofilm become essential to the success and longevity of implant therapy. The consequences of surface roughness generated by these procedures have been evaluated, but new proposals for decontaminating implant surfaces have been used mainly to treat periimplantite. Thus the objective was to evaluate, in vitro, the surface roughness of cylindrical titanium discs treated by plastic curette; bicarbonate jet; smear tetracycline or piezoelectric ultrasound. A total of 50 titanium discs with dimensions of 5 mm high and 5 mm wide, surfaces blasted with aluminum oxide were used. The discs were randomly divided into five groups: group 1 (n = 10)control - no treatment, group 2 (n = 10) received 15 scraping motions with plastic curette, group 3 (n = 10) application of bicarbonate jet for 30 seconds to five millimeters of distance from the surface and group 4 (n = 10) application of vigorous scraping with 50mg/ml tetracycline acid on the surface of the discs for 30 seconds and group 5 (n = 10) application of 15 scraping movements with teflon tip by ultrasonic piezoelectric with polisher irrigation solution. After treatment, three parallel and three perpendicular readings were taken to the direction of the instrumentation using a rugosimeter in order to obtain surface roughness parameters Ra which represents the arithmetic mean of the absolute values of all deviations from the surface in relation to the median in the area of sampling, and Rz which represents the average between the absolute height of the Five highest peaks and the absolute values of the 5 deepest valleys exist in the length of sampling. Furthermore, the discs were evaluated in scanning electron microscopy, an increase of 100X and 1000X, to visualize the surface topography after the procedures. Statistical analysis was performed using the Kruskal-Wallis test with a significance level of 5% compared to the values of surface roughness of each group. The lowest roughness Ra was obtained in the group of piezoelectric ultrasound (0.89 ± 0.06 µm) compared to control (0.85 ± 0.03 µm). The use of tetracycline acid was the treatment which increased the roughness (0.99 ± 0.09 µm) was statistically different from the control group (p _ 0.05). Regarding the parameter Rz, the results showed that the smear of tetracycline and plastic curette had the highest values of Rz (8.37±0.76 µm e 8.49±0.74µm, respectively) statistically different to control group (7.33 ± 0.34 µm) with significance 5%. Moreover, as the values of Ra, the use of piezoelectric ultrasound (7.85 ± 0.69 µm), the values of Rz, did not cause a significant change in the surface so as to be statistically different in the control group. The study concludes that use of piezoelectric ultrasound did not cause significant increase in surface roughness of titanium discs in the parameters of Ra and Rz. The bicarbonate jet obtained values statistically similar to other groups in both parameters .The group of plastic curette and smear tetracycline acid generated values statistically different from the control and ultrasound in piezoelectric parameter Rz. All groups presented visually, from the pictures on scanning electron microscopy, changes on its surface / Mestrado / Periodontia / Mestre em Clínica Odontológica
47

Influencia da radiação nas propriedades de compositos odontologicos / Influence of radiation on properties of composite restorative resin

Viero, Flavio Luiz 25 July 2006 (has links)
Orientador: Frab Norberto Boscolo / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-06T22:46:39Z (GMT). No. of bitstreams: 1 Viero_FlavioLuiz_D.pdf: 553886 bytes, checksum: 6455fb7d1e46ecd9328257967d685d33 (MD5) Previous issue date: 2006 / Resumo: O objetivo neste estudo foi avaliar o efeito de diferentes doses de radiação X produzida a partir do Cobalto -60, em dois tipos de materiais odontológicos: o compósito Filtek TM A 110 3M, utilizado para restauração d e dentes anteriores; e o compósito condensável SureFilTM indicado para restauração cB dentes posteriores. Foram confeccionados 70 corpos de prova, dos quais 25 foram destinados ao teste de dureza Knoop e 50 ao teste de rugosidade de superfície. Depois de confeccionados, os corpos de prova foram acondicionados em caixas de acrílico e submersos em água destilada por um período de 24 horas, tendo com finalidade obter-se a estabilização química dos materiais. Após esse período, foram submetidos ao teste de Microdureza e de rugosidade de superfície. Obtidas essas medidas, os corpos de prova foram submetidos à irradiação, com as seguintes doses: 0,25Gy; 0,50Gy; 0,75Gy; 1Gy. Passadas 24 horas da irradiação, os mesmos 25 corpos de prova foram novamente submetidos ao teste de microdureza e os mesmos 50 éD teste de rugosidade. Logo após a realização do teste de rugosidade, os 50 corpos de prova foram submetidos à abrasão, sendo a seguir submersos em água destilada, permanecendo por 24 horas. Após esse período, um terceiro teste de rugosidade de superfície foi realizado nesses corpos de prova. De posse das medidas obtidas e após estas serem submetidas à análise estatística - Teste Tukey e o teste T pareado, observou-se que os tipos de compósitos irradiados apresentaram uma redução estatisticamente significante, nos valores de dureza Knoop, quando comparados ao material não irradiado; entretanto não foi observada diferença significante entre os grupos irradiados. Quando avaliada a rugosidade, observou-se que não houve diferença entre o grupo controle e o irradiado; entretanto houve diferença estatisticamente significante, dentro de cada grupo, antes e após os corpos de prova terem sido submetidos à abrasão. Conclui-se que, portanto, que a irradiação influenciou a dureza Knoop, mas não interferiu na rugosidade dos dois compósitos avaliados / Abstract: The aim of the present study was to evaluate the effects of different )f radiation doses produced by cobalt-60 teletherapy unit on two types of restorative dental materials: 3M Filtek TM A 110 used for forward teeth restorations and condensable SureFilTM used for back teeth restorations. Seventy five specimens were fabricated, 25 were submitted to Knoop hardness test and 50 to surface roughness. Next, the samples were immersed in distilled water in an acrylic support for chemical stabilization for 24 hours, and evaluated before irradiation test. Afterwards the samples were submitted to microhardness test and to surface roughness. Subsequently, samples were irradiated with single doses of 0,25Gy; O,50Gy; 0,75Gy; 1Gy. Twenty four hours after irradiation, the same samples were evaluated considering both tests - roughness and microhardness. After these procedures, the 50 samples used for the roughness surface evaluation were submitted to abrasion and stored in distilled water for 24 hours. After this period, the roughness surface were again analyzed. Data were submitted to Tukey test and to paired t-test, and it was observed that the two irradiated composites had a statistically significant reduction in Knoop hardness values when compared to non­irradiated composites adversely, no statically significant differences were found among the irradiated groups. Regarding surface roughness, no statistically significant difference was observed in the comparisons between the control group and irradiated group, however statistically significant differences were found inside each group, before and after the samples have been submitted to abrasion. It was concluded that the x-irradiation influenced the Knoop hardness, therefore it did not interfere on the surface roughness of the two restorative composite evaluated. / Doutorado / Radiologia Odontologica / Doutor em Radiologia Odontológica
48

Efeito de diferentes desafios sobre as propriedades de superfície dos sistemas restauradores que simulam os tecidos gengivais / Effect of different challenges on the surface properties of restorative systems that simulate gingival tissues

Erika Michele dos Santos Araujo 07 June 2018 (has links)
O uso de compósitos simulando a cor dos tecidos gengivais apresenta-se como uma opção de tratamento restaurador estético com aplicação direta, que pode aumentar a satisfação do paciente por meio de uma solução de baixo custo e pouco invasiva. Este estudo teve como fatores de variação: sistemas restauradores que reproduzem a cor dos tecidos gengivais (Amaris® gingiva (A), NTpremium® Pink (B), Beautifil® II Pink (C) e protocolo de envelhecimento [desafio erosivo (DE) e ciclagem térmica (CT)], avaliados quanto a estabilidade de cor, rugosidade superficial, perda de superfície e quantificação de biofilme. Para os 3 primeiros ensaios, os espécimes foram divididos em 6 grupos (n=10): G1 (A+CT); G2 (A+DE); G3 (B+CT); G4 (B+DE); G5 (C+CT); G6 (C+DE). A ciclagem térmica foi realizada com um total 5.000 ciclos, com banhos de 5ºC e 55ºC e o desafio erosivo consistiu da armazenagem dos espécimes em solução de ácido cítrico 0,3%, com pH 2,5 a 37°C, durante uma semana. Sessenta espécimes de 5mmX5mmX3mm foram montados, fotopolimerizados, polidos e armazenados em estufa a 37º por 24h. Todos os espécimes foram lidos antes e após os protocolos de envelhecimento, utilizando o perfilômetro óptico para avaliação da rugosidade superficial e a perda de superfície, enquanto o espectrofotômetro avaliou a estabilidade de cor dos compósitos, de acordo com os parâmetros do CIELab. Para a quantificação do biofilme foram acrescentadas duas variáveis tempo de leitura (após 3 e 24 horas) e ao protocolo de envelhecimento foi adicionado um grupo controle (sem envelhecimento). Noventa (n=5) espécimes de 4mmX1mm foram montados e padronizados como os espécimes montados para as leitura de rugosidade, perda de superfície e alteração de cor. Para a formação do biofilme foram utilizadas as cepas de Streptococcus mutans UA159, cultivadas em TSB suplementado com 0,5% de sacarose por 3 e 24 horas e mensurados através do método indireto de coloração com safranina e leitura de absorbância para a quantificação do biofilme formado. No que se refere a alteração de cor, detectou-se diferença estatisticamente significante para os fatores sistema restaurador (p=0,00) e para a interação sistema restaurador X protocolo de envelhecimento (p=0,00). A maior variação de cor foi observada no material C quando submetido ao desafio erosivo (16,75±3,25). A ANOVA não detectou diferença estatisticamente significante para nenhum dos fatores em relação a perda de superfície. Na avaliação da rugosidade, detectou-se diferença estatisticamente significante para o fator protocolo de envelhecimento (p=0,00), havendo maior rugosidade para os espécimes submetidos à ciclagem térmica. Na quantificação de biofilme, após 3 e 24 horas, ANOVA detectou diferença estatisticamente significante para o fator protocolo de envelhecimento (p=0,00) e para a interação entre o protocolo de envelhecimento e material restaurador (p=0,00 e p=0,003, respectivamente). Conclui-se que todos os sistemas restauradores apresentaram alteração de cor após os protocolos de envelhecimento testados. A CT foi o protocolo de envelhecimento que mais aumentou a rugosidade em todos os sistemas restauradores, contudo sem perda significante de superfície. A quantificação de biofilme após 3 e 24 horas foi aumentada pelos protocolos de envelhecimento. O desafio erosivo aumentou a deposição de biofilme no sistema restaurador giomer, em 3 e 24 horas. / The use of composites simulating the color of the gingival tissues presents as an option of aesthetic restorative treatment with direct application, which can increase patient satisfaction through a low-cost and non-invasive solution. This study had as factors of variation: restorative systems that reproduce the color of the gingival tissues (Amaris® gingiva (A), NTpremium® Pink (B), Beautifil® II Pink (C) and aging protocols [thermal cycling (TC) and erosive challenge (EC)], evaluated for color stability, surface roughness, surface loss and biofilm quantification. For the first 3 trials, the specimens were divided into 6 groups (n = 10): G1 (A + TC); G2 (A + EC); G3 (B + TC); G4 (B + EC); G5 (C + TC); G6 (C + EC). The thermal cycling was performed with a total of 5.000 cycles, with baths of 5 ° and 55 ° C and the erosive challenge consisted of the storage of the specimens in 0.3% citric acid solution, pH 2.5 at 37°C, for one week. Sixty specimens of 5mmX5mmX3mm were mounted, photopolymerized, polished and stored in destilled water at 37º for 24h. All the specimens were read before and after the aging protocols, using the optical profilometer to evaluate surface roughness and surface loss, while the spectrophotometer evaluated the color stability of the composites, according to CIELab parameters. Two reading time variables (after 3 and 24 hours) were added to the biofilm quantification and a control group (without aging) was added to the aging protocol. Ninety (n=5) specimens of 5mmX1mm were mounted and standardized as the specimens or the first 3 trials, roughness, surface loss and color stability. For the biofilm formation, Streptococcus mutans UA159, cultivated in TSB supplemented with 0.5% of sucrose for 3 and 24 hours and measured by the indirect method of safranin staining and absorbance reading were used. Regarding the color change, a statistically significant difference was detected for the factors restorative system (p=0.00) and for the interaction restorative system X aging protocol (p=0.00). The highest color variation was observed in material C when submitted to erosive challenge (16.75 ± 3.25). ANOVA did not detect a statistically significant difference for any factors in relation to surface loss. In the evaluation of roughness, a statistically significant difference was detected for the aging protocol factor (p=0.00), with a higher roughness for the specimens submitted to thermal cycling. In the biofilm quantification, after 3 and 24 hours, ANOVA detected a statistically significant difference for the aging protocol factor (p=0.00) and for the interaction between the two factors, aging protocols and restorative systems (p=0.00 and p=0.003, respectively). It was concluded that all restorative systems presented color changes after the aging protocols tested. CT was the aging protocol that increased the most roughness in all restorative systems, nevertheless without significant loss of surface. Biofilm deposition after 3 and 24 hours varies considerably depending on the restorative system and aging protocol. The erosive challenge increased biofilm deposition in the restorative system giomer in 3 and 24 hours.
49

Avaliação da estabilidade de cor e rugosidade superficial de resinas compostas micro-híbridas, submetidas ao processo de envelhecimento artificial acelerado, em função da fotoativação com lâmpada halógena e LED / Color stability and surface roughness of micro hybrids resins polymerized by LED or halogen light irradiation after accelerated aging.

Odirlei Arruda Malaspina 14 September 2009 (has links)
O estudo avaliou, in vitro, as variáveis relacionadas à alteração de cor e à rugosidade superficial das resinas compostas micro-híbridas: Charisma (Heraeus-Kulzer), Filtek Z-250 (3M - Espe), Herculite XRV (Kerr), Opallis (FGM), TPH Spectrum (Dentsply) e W3D (Wilcos), antes e após o envelhecimento artificial acelerado, tendo como fatores de variação duas fontes de luz, lâmpada halógena e LED, com densidades de potência de 300 mW/cm2 ou 600 mW/cm2. Foram confeccionados 240 corpos-de-prova distribuídos em grupos de 10 unidades para cada condição de estudo totalizando 24 grupos constituídos por 4 protocolos de fotoativação para cada marca de resina composta. Estes corpos-de-prova foram armazenados em água deionizada, ao abrigo de luz e a temperatura de 37oC por 1 semana quando então receberam polimento superficial com discos Diamondpro (FGM). Sequencialmente, os mesmos foram submetidos às análises iniciais de rugosidade superficial (rugosímetro Hommle Tester T1000 basic) e de cor (Espectrofotômetro EasyShade). Decorridas 24 horas, os espécimes foram submetidos ao Sistema de Envelhecimento Acelerado para materiais não metálicos C-UV por 384 horas quando então foram novamente realizadas as leituras de rugosidade e cor. Os valores de rugosidade superficial e alteração de cor das resinas compostas, após o processo de envelhecimento acelerado, demonstraram alterações significativas, sendo os valores de E muito superiores ao considerado clinicamente aceitável (E3,3). De forma geral, o efeito exercido pelos protocolos de fotoativação não permitiu distinguir a influência direta das irradiâncias das fontes de luz no comportamento das diferentes resinas compostas, observando-se uma correlação positiva média entre rugosidade superficial e a alteração de cor. / This study aimed to evaluate changes in color and surface roughness, before and after artificial accelerated aging of six micro hybrids composites resins (comparable to Vita shade A2) cured by quartz tungsten halogen (H) or a light emitting diode (L) polymerization unit with 300 mW/cm2 or 600 mW/cm2. Forty disc specimens (7 x 2 mm) were prepared for each composite (Charisma®, Filtek Z-250®, Herculite XRV®, Opallis®, TPH Spectrum®, W3D®), being 10 specimens for each condition (Q 300/600 mW/cm2 or L 300/600 mW/cm2). After cured, each specimen was evaluated by color (Easy Shade® spectrophotometer) according to CIE L*a*b* color scale and by surface roughness (Hommelwerke GmbH ) Ra values before and after submitting to artificial accelerated aging (4 h UV-B/4 h condensing vapor) for 384 hours total. The surface roughness and color change values of composite resins, after the process of accelerated aging, showed significant changes. Also, the values of E after accelerated aging were much higher than the values considered clinically acceptable (E 3.3). In general, the protocols curing effects showed varied influence over different composite resins and a positive correlation between average change in surface roughness and color change after accelerated aging process.
50

Influência da rugosidade e energia livre de superfície de materiais para próteses removíveis a base de polimetilmetacrilato nas propriedades do biofilme de Candida albicans / Influence of the roughness and free energy surfasse of the materials for removable prosthesis the base of polymethymethacrylate in the properties of biofilm of Candida albicans

Leal, Cristiane Maria Brasil, 1965- 18 August 2018 (has links)
Orientador: Célia Marisa Rizzatti Barbosa / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-18T20:42:48Z (GMT). No. of bitstreams: 1 Leal_CristianeMariaBrasil_D.pdf: 1004692 bytes, checksum: 29697b5c7bdbece2ba32ca361de7e805 (MD5) Previous issue date: 2011 / Resumo: As propriedades de superfície de resinas e reembasadores a base de polimetilmetacrilato utilizados em próteses dentais removíveis podem interferir na adesão, colonização e formação do biofilme de Candida spp., microrganismo associado à estomatite protética. O objetivo desta pesquisa foi avaliar a influência da rugosidade e da energia livre de superfície de uma resina a base de polimetilmetacrilato e um reembasador rígido na adesão e estrutura de biofilmes de Candida albicans. Discos de resina acrílica termopolimerizável e de reembasador rígido à base de polimetilmetacrilato foram confeccionados nas dimensões de 10 x 2 mm. As diferentes rugosidades de superfície dos espécimes foram obtidas por meio de diferentes acabamento/polimento. A energia livre de superfície variou pela formação de películas de saliva ou plasma ou a combinação de ambos sobre os espécimes. Após a mensuração da rugosidade e da energia livre de superfície, os espécimes foram divididos aleatoriamente de acordo com os grupos experimentais. Biofilmes de Candida albicans ATCC 90028 foram formados sobre as superfícies e avaliados quanto à contagem celular, bioatividade e arquitetura (bio-volume, espessura média e rugosidade média) nas fases de adesão e após 48 horas. Os dados foram analisados utilizando-se a análise de variância a dois critérios seguido do teste de Tukey. O nível de significância foi de p=0,05. Os resultados revelaram que mesmo havendo diferenças significantes (p<0,001) entre os valores da rugosidade, isto não se refletiu nos parâmetros avaliados do biofilme de C. albicans no período de 48 horas. Não houve diferença significativa nos valores da energia livre de superfície, no entanto, a diferença das películas provocou alterações significativas do biofilme de C. albicans na fase de adesão e 48 horas (p>0,05). Pode-se concluir que a alteração da rugosidade de superfície não afeta a estrutura do biofilme de C. albicans de 48 horas, no entanto, a alteração da energia livre de superfície por meio da deposição de proteínas salivares e/ou plasmáticas altera a estrutura do biofilme nas fases de adesão e 48 horas / Abstract: The properties of surface of the resins and reliners base of polymethymethacrylate used in removable dental prosthesis can interfere in the adhesion, colonization and formation of biofilm of Candida spp., microorganism associated to the prosthetic stomatitis. The objective of this research was to evaluate the influence of the roughness and the free energy of surface of the resin the base of polymethymethacrylate and a rigid reliner in the adhesion and structure of biofilms of C. albicans. Discs of the termopolymerized acrylic resin and rigid reliner to the base of polymethymethacrylate had been confectioned in the dimensions 10 x 2 mm. The differents roughness of surface of the specimens were obtained by means of different finishing/polishing. The free energy of surface varied for the formation of pellicle of saliva or serum or the combination of both on the specimens. After the measurement the roughness and the free energy of surface, the specimens were divided randomly in accordance to the experimental groups. Biofilms of Candida albicans ATCC 90028 were formed on the surfaces and evaluated for cell count, bioactivity and architecture (bio-volume, average thickness and average roughness) in the adhesion phases and after 48 hours. The data were analyzed using analysis of variance with two criteria followed by the Tukey test. The significance level was p=0,05. The results showed that even with significant differences (p<0.001) between the values of roughness, it did not reflect in the parameters evaluated of biofilm of C. albicans in 48 hours. There was no significant difference in the values of the free energy of surface; however, the difference of the pellicles caused significant alterations of biofilm of C. albicans in the adhesion phase and 48 hours (p>0,05). It can be concluded that the alteration of the roughness of surface don't affect the structure of biofilm of C. albicans of 48 hours, however, the alteration of the free energy of surface by deposition of salivary and/or serum proteins modifies the structure of biofilm in the adhesion phases and 48 hours / Doutorado / Protese Dental / Doutor em Clínica Odontológica

Page generated in 0.0444 seconds