• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 291
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 302
  • 250
  • 120
  • 98
  • 56
  • 39
  • 36
  • 35
  • 35
  • 34
  • 33
  • 27
  • 27
  • 26
  • 23
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Parâmetros de rugosidade aerodinâmica sobre vegetação esparsa / Aerodynamic roughness parameters over sparse vegetation

Lyra, Gustavo Bastos 16 February 2006 (has links)
Para vegetação esparsa e de porte alto a determinação dos parâmetros de rugosidade é comprometida pela dificuldade em se observar condições que satisfaçam a lei logarítmica da velocidade do vento. Estimou-se o comprimento de rugosidade (z0) e o deslocamento do plano zero (d) por alguns métodos com medidas micrometeorológicas e da estrutura física de arbustos esparsos em região semi-árida, durante o experimento HAPEX-Sahel. A velocidade do vento foi medida em quatro alturas acima da superfície (3,0; 4,1; 5,3 e 8,5 m), e os fluxos determinados por correlações dos turbilhões a 9m de altura. Métodos baseados no perfil logarítmico foram aplicados em condições de atmosfera neutra. A altura média da vegetação era h = 2,06 ± 0,47 m. O método convencional (ajuste estatístico) resultou em estimativas satisfatórias de d e z0 em condições nas quais a validade do perfil logarítmico foi satisfeita. Com uma única altura de medida localizada acima da subcamada inercial as estimativas resultaram em valores ou fisicamente inconsistentes ou que não caracterizam a rugosidade da superfície. Quando se utilizou a velocidade de fricção dada pela correlação dos turbilhões na solução do perfil logarítmico, as estimativas melhoraram. A combinação do perfil logarítmico com a relação z0 = λ (h - d) proporcionou estimativas satisfatórias para os valores de λ = 0,188 e 0,190 determinados em função da estrutura física da vegetação, o que não foi observado para o valor médio da literatura (0,166). Relações entre a estrutura física da vegetação e o transporte de momentum estimaram apropriadamente d e z0. A rugosidade da área foi melhor descrita por d = 0,95 m = 0,46 h e z0 = 0,204 m = 0,1 h, sendo λ = 0,185. As velocidades horizontal do vento e de fricção foram mais sensíveis a variações em z0 do que em d. / For sparse and tall vegetation the estimate of roughness parameters is compromised by the difficulty in observing conditions that satisfy the windspeed logarithmic law. The roughness length (z0) and the zero-plane displacement (d) were estimated by some methods with micrometeorological measurements and the physical structure of sparse shrubs in semi-arid region, during the HAPEX-Sahel experiment. The wind speed was measured at four heights above of surface (3.0, 4.1, 5.3 and 8.5 m), and the turbulent flows determined by eddy correlations at the height of 9m. Methods based on the logarithmic profile have been applied in neutral atmosphere conditions. The average height of the vegetation was h = 2.06 ± 0.47 m. The conventional method (statistical fit) resulted in good estimates of d and z0 only under conditions of validity of the logarithmic law. Only one height of measurement located above of the inertial sublayer is enough to result in physically inconsistent values. When the friction velocity, given by eddy correlation, was used in the logarithmic law, the estimates improved. The combination of the logarithmic law with z0 = λ (h - d) provided satisfactory estimates of the surface roughness for λ = 0.188 and 0.190 determined in function of the physical structure of the vegetation; but for λ = 0.166, the average value of literature, the estimates where not good. Relationships between the physical structure of the vegetation and the momentum transfer estimated appropriately d and z0. The area roughness was better described by d = 0.95 m = 0.46 h and z0 = 0.204 m = 0.1 h, being λ = 0.185. Wind speed and friction velocity were more sensible to variations in z0 than in d.
62

Avaliação clínica do efeito de dentifrícios clareadores na cor e rugosidade do esmalte dental e compósitos odontológicos / Clinical evaluation of color and surface roughness of dental enamel and dental composites submitted to brushing with whitening toothpaste

Roselino, Lourenço de Moraes Rego 11 August 2015 (has links)
Os objetivos deste estudo foram avaliar clinicamente a alteração de cor e de rugosidade de superfície do esmalte dental e de compósitos odontológicos, submetidos à escovação com dentifrícios clareadores e a ação deles sobre a degradação das pontas das cerdas da escova dental. Foram obtidos 30 corpos-de-prova (6mm de diâmetro X 2mm de espessura) de cada compósito (Z250 e Z350, 3M ESPE e Tetric N-Ceram, Ivoclar Vivadent). Em seguida, estes foram aleatoriamente fixados na face vestibular dos primeiros molares superiores (direito e esquerdo) e de um segundo molar superior (direito ou esquerdo) de 30 participantes selecionados para o estudo, de acordo com os critérios de inclusão determinados. Após a fixação dos espécimes, os participantes receberam escovas de dentes (Oral B Classic, Procter & Gamble) e dentifrício convencional (Sorriso Dentes Brancos, Colgate-Palmolive) e foram orientados a utilizar esses produtos durante 7 dias (período pré-experimental) após o qual foram realizadas as leituras iniciais de cor (Easyshade, VITA) e de rugosidade de superfície (Rugosímetro Surfcorder SE 1700, Kosakalab) das amostras e também do esmalte dental de um dos incisivos centrais superiores dos participantes. Para as leituras de rugosidade foi realizada moldagem (Express, 3M ESPE) do incisivo central superior e dos corpos-de-prova fixados para posterior obtenção de modelos com resina de poliuretano (Axon F16, Abcol) para confecção de réplicas, sobre as quais foram realizadas as leituras. Após as leituras iniciais, os participantes foram separados em 3 grupos (n=10), conforme o dentifrício clareador utilizado: Grupo 1) Dentifrício controle (Sorriso Dentes Brancos); Grupo 2) Dentifrício clareador (Colgate Luminous White, Colgate-Palmolive); e Grupo 3) Dentifrício clareador de ação rápida (Close up White Now, Unilever). As cerdas das escovas dentais utilizadas pelos participantes foram analisadas por MEV (Microscópio XL30 Field Emission Gun, Philips), em duas regiões da escova: periférica e central. Os períodos de análise da ação dos dentifrícios clareadores foram, 7, 30 e 90 dias. Os valores das medições (antes e após os períodos de testes) foram analisados estatisticamente (3-way-ANOVA, medidas repetidas, Tukey, p<0,05) e os resultados demonstraram que não houve alteração de cor significativa dos substratos analisados independentemente do tipo de dentifrício utilizado, mas o tempo de utilização de um dentifrício sobre os compósitos foi significante para a alteração de cor. Não houve alteração de rugosidade de superfície do esmalte dental, independente do dentifrício utilizado. A alteração de rugosidade de superfície dos compósitos é material dependente, mas o tempo de escovação com esses dentifrícios não interfere nessa propriedade. Quanto maior o tempo de escovação, maior o desgaste da ponta das cerdas da escova, independente do dentifrício utilizado e da região a que ela pertence. Conclui-se que a alteração de cor e de rugosidade de superfície dos compósitos é material-dependente e tempo-dependente para a alteração de cor e para degradação das cerdas da escova. / The aims of this study were to clinically evaluated the color change and the surface roughness of enamel and dental composites submitted to brushing with whitening toothpaste and the their action over the degradation of the tips of the bristles of the toothbrush. 30 specimens were obtained (6 mm diameter X 2mm thick) of each composite (Z250 and Z350, 3M ESPE and Tetric N-Ceram, Ivoclar Vivadent). Then, the specimens were randomly bonded on the maxillary first molars buccal surfaces (right and left sides) and the one maxillary second molar (right or left sides) of 30 participants, which were selected for the study according to inclusion criteria. After specimens bonding, participants received toothbrush (Oral B Classic, Procter & Gamble) and non whitening toothpaste (Sorriso Dentes Brancos, Colgate-Palmolive) and also they were instructed to use these products for 7 days (pre-trial). After that, were realized the initial color (Easyshade, VITA) and surface roughness (Roughness Surfcorder SE 1700, KosakaLab) readings of specimens and of the enamel of the maxillary central incisors of the participants. For surface roughness readings was performed molding (Express, 3M ESPE) of the maxillary central incisor and of the specimens fixed to be retrieved later of the models with polyurethane resin (Axon F16, Abcol). Then in these replicas were made surface roughness readings. After baseline measurements, participants were divided into 3 groups (n=10), according to the whitening toothpaste used: Group 1) Control toothpaste (Sorriso Dentes Brancos); Group 2) Whitening toothpaste (Colgate Luminous White, Colgate-Palmolive); and Group 3) Whitening toothpaste with fast action (Close up White Now, Unilever). The bristles of toothbrushes used by the participants were analyzed by SEM (Field Emission Gun Microscope XL30, Philips) in two regions of the brush: peripheral and central. The periods of action analysis of whitening toothpaste were 7, 30 and 90 days. The measured values (before and after the testing periods) were statistically analyzed (3-way ANOVA, repeated measures, Tukey, p <0.05) and the results showed no significant color change of the substrates analyzed independently of the type toothpaste used, but the time of use of a dentifrice over the composites was significant for the color change. There was no surface roughness change enamel independently of the toothpaste used. The surface roughness change of composites is dependent on material, but the time of brushing with these toothpaste does not interfere in this property. The longer the time of brushing, the greater the degradation in the tips of the bristles of the toothbrush independently of the toothpaste used and the region to which it belongs. It is conclude that the color change and surface roughness of the composites is material-dependent and time-dependent to color change and to degradation of the brush bristles.
63

Alteração de cor e rugosidade superficial de resina composta clareada após envelhecimento em função do tempo / Color change and surface roughness of composite resin cleared after accelerated artificial aging as a function of time

Freitas, Daniela de Biagi 30 July 2010 (has links)
O presente trabalho teve como objetivo analisar &ldquo;in vitro&rdquo; a alteração de cor e a rugosidade superficial de uma resina composta (Charisma®) submetidas a tratamento clareador com agente clareador Lase Peroxide Sensy® (CC) e grupo controle sem tratamento clareador (SCL), após envelhecimento (EAA) em função do tempo, realizando-se avaliação superficial complementar por meio de Microscopia Eletrônica de Varredura (MEV) e EDX. Os corpos-de-prova (n=15) foram confeccionados com o auxílio de uma matriz de Teflon nas dimensões de 11x2,0mm, polidos com discos Soft Lex®, na seqüência de abrasividade decrescente e armazenados em saliva artificial a 37ºC (±1ºC), até os momentos de serem submetidos aos tratamentos propostos e à realização das leituras de alteração de cor e rugosidade superficial, nos tempos: 24 horas após a confecção (T0), após envelhecimento artificial acelerado (T1), 24 horas após clareamento (T2), 7dias (T3) e 1 mês após clareamento (T4). As leituras de alteração de cor foram obtidas com o auxílio do aparelho Espectrofotômetro (PCB6807BYK GARDNER) e para as leituras de rugosidade superfícial foi utilizado o Rugosímetro Mitutoyo SJ201P. Os dados foram submetidos à Análise de Variância ANOVA (p&le;0,05). Os resultados obtidos foram: a) o fator Tempo teve efeito estatisticamente significante sobre as variáveis &Delta;E* (T1=T2=T3; T1=T4), L* (T0&lt;T1=T2=T3=T4), a* (T0&gt;T1=T2; T1=T3=T4; T4&gt;T2), b* (T0&gt;T1=T2=T3; T4=T3=T1; T2&lt;T4) e rugosidade superficial (&mu;m) (T0&lt;T1,T2,T3,T4; T1=T2; T1&lt;T3=T4; T2=T3=T4; b) para o fator tratamento com relação a &Delta;E* e fator L*(CC&gt;SCL), para os fatores a* e b*(CC&lt;SC), c) a interação Tratamento x Tempo não apresentou diferença estatisticamente significante para as variáveis &Delta;E*, L*, a*, b* e rugosidade superficial, d) as superfícies após EAA apresentaram alterações d) não houve mudanças no EDX antes e após os tratamentos. Conclui-se que a resina Charisma®, apresentou alteração de cor (&Delta;E*&gt;3,3) e uma estabilidade na rugosidade superficial a partir de T2. / The current study in vitro evaluated the color change and surface roughness of the composite resin Charisma® cleared with Lase Peroxide Sensy® (CCL) and control without bleaching (SCL) after accelerated artificial aging (EAA) as a function of time, performing additional surface evaluation by scanning electron microscopy (MEV) and EDX. To obtain the color change and surface roughness a Spectrophotometer (PCB 6807 BYK GARDNER) and rugosimeter (Mitutoyo SJ- 201P) were employed respectively. Measurements were carried out at five times: 24 hours after preparation (T0), after artificial accelerated aging (T1), 24 hours after bleaching (T2), 7days (T3) and 1 month after bleaching (T4). The specimens (n=15) were prepared with aid of a Teflon (10-mmin diameter and 2mm thick). The specimens were polished with discs Soft Lex®, following abrasiveness decreased, being stored in artificial saliva at 37ºC (±1ºC) until the time of undergoing the proposed treatments and the measurements. The data obtained were submitted to ANOVA parametric test (p &le; 0.05). The results were: a) time factor had a statistically significant effect on the variables &Delta;E* (T1 = T2 = T3, T1 = T4), L*(T0 &lt;T1 = T2 = T3 = T4), a* (T0 &gt; T1 = T2; T1=T3 =T4, T4&gt;T2), b* (T0&gt; T1=T2=T3, T4=T3=T1; T2&lt;T4) and roughness(&mu;m) (T0&lt;T1,T2, T3,T4; T1 = T2; T1&lt;T3=T4; T2=T3=T4), b) for treatment factor &Delta;E* and L* (CC&gt; SCL) for the factors a*and b* (CC &lt;SC), c) Treatment x Time interaction showed no statistically significant difference for the variables &Delta;E*, L*, a*, b* and surface roughness, d) after EAA the surfaces change d) before and after EAA dont have changes. It is concluded that the resin Charisma®, presented color change (&Delta;E *> 3.3) and surface roughness stability from T2.
64

Investigações sobre o acabamento superficial de usinagens com altíssima velocidade de corte. / Investigations on the quality of high-speed machined surfaces.

Faccio, Ian 14 February 2003 (has links)
Corpos de prova de ferro fundido foram usinados com altíssima velocidade de corte. Tiveram diversos parâmetros de sua rugosidade medida e os valores foram descritos em gráficos de rugosidade versus profundidade de corte. Pode-se verificar uma dependência entre estes valores, mas não o clássico aumento da rugosidade conforme o aumento da profundidade de corte. Realizou-se ainda a inspeção metalográfica dos corpos de prova na busca de mudanças de fase na estrutura ferro carbono que indiquem temperaturas elevadas no local, causadas pela alta velocidade de corte. / Cast iron test parts were high-speed machined. They had several roughness parameters measured and these values were plotted on roughness versus depth of cut charts. It could be noticed a relation between these values, but not the classical roughness increase due to the increase of depth of cut. Moreover, the metalographical analisys was performed for these test parts, in a search for phase changes on the carbon-iron structure which indicate high temperatures at the region, caused by the high cutting speed.
65

Análise da estabilidade de cor e rugosidade de superfície de compósitos submetidos à fumaça de cigarro / Color stability and surface roughness of dental composites exposed to cigarette smoke

Román, Carla Cecília Alandia 29 November 2011 (has links)
O objetivo deste estudo foi avaliar a estabilidade de cor e rugosidade de superfície de 3 compósitos odontológicos com partículas diferentes: nanohíbrido (Tetric N-Ceram - Ivoclar Vivadent), híbrido (Z250 - 3M ESPE) e microhíbrido com matriz silorano (Filtek P90 3M - ESPE), submetidos à fumaça de cigarro. Para isso, foram obtidos 60 corpos-de-prova (8mm de diâmetro X 2mm de espessura), 20 para cada tipo de material restaurador utilizado, dos quais 10 receberam polimento com lixas dágua em abrasividades decrescentes (Grupo1) e a outra metade não foi submetida a nenhum tipo de acabamento/polimento ficando sob efeito apenas de uma matriz de poliéster (Grupo 2). Após armazenamento dos corpos de prova em água destilada a 37°C por 24 horas, foram realizadas as primeiras leituras de cor (Colorímetro Vita Easy Shade) na escala de cor CIEL*a*b* e rugosidade superficial (Rugosímetro Surfcorder SE 1700 - Kosakalab). Em seguida, as amostras foram expostas à fumaça de 20 cigarros por um período de 10 minutos cada, (Marlboro - Philip Morris), sendo que entre um cigarro e outro as amostras foram submetidas à escovação em dispositivo padronizado e lavagem em água corrente. Após ação do número total de cigarros, foram realizadas leituras finais de cor e rugosidade. Os valores de &Delta;E, &Delta;L, &Delta;a e &Delta;b foram analisados estatisticamente utilizando 2 way ANOVA e Teste de Bonferroni (p<0.05) e os valores de rugosidade média (Ra) foram analisados isoladamente para cada tipo de material (teste t Student, p < 0.05). Verificou-se que o compósito Tetric N apresentou maior alteração de cor, em níveis clinicamente inaceitáveis (&Delta;E>3,3) e de rugosidade de superfície em relação aos demais compósitos quando utilizada a tira de poliéster como acabamento. Concluiu-se que a ausência de polimento aumenta a capacidade manchadora do cigarro sobre todos os compósitos e a rugosidade de superfície dos materiais, com exceção de P90. / The purpose of this study was to evaluate the color stability and surface roughness of three dental composites with different type of fillers: Nanohybrid (Tetric N-Ceram), Hybrid (Filtek Z250-3M ESPE) and Microhybrid silorane based composite (Filtek P90- 3M ESPE), exposed to cigarette smoke. 20 specimens (8mm diameter X 2mm thickness) of each material were prepared and separated into two groups (n=10) according to the surface treatment : Group 1- polymerization through a polyester film strip and polishing with water sandpaper in decreasing abrasiveness (600, 800 e 1200); and Group 2- polymerization through a polyester film strip, without any polishing. After immersion in destilled water 37° for 24 hours, baseline color of all specimens was measured using reflectance spectrophotometer (Easy Shade - Vita) with CIEL*a*b* system, surface roughness was also measured using a rugosimeter (SJ-201P Mitutoyo, Tokyo, Japan). After base line measurements, the specimens were exposed to smoke from 20 cigarettes in 10 minutes each, (Marlboro - Philip Morris), between one cigarette and other, the specimens were submitted to brushing in a standardized device and washed with water. After the action of the total number of cigarettes, final measurements of color and surface roughness were performed. Values of &Delta;E, &Delta;L, &Delta;a e &Delta;b were statistically analyzed using 2 way ANOVA e Teste de Bonferroni (p<0.05) and values of average surface roughness (Ra) were analyzed separately for each type of material (teste t Student, p < 0.05). It was found that the composite Tetric N-Ceram showed increased of surface roughness and greater color change in clinically unacceptable levels (&Delta;E>3,3), in comparison with the other composites when used the polyester strip without polishing. It was concluded that the absence of polishing increases the cigarette staining and surface roughness on all composites except for Filtek P90.
66

Estudo da usinabilidade de chapas MDF (Medium Density Fiberboard) para usinagem de desbaste e acabamento / not available

Castro, Eduardo Martins de 28 February 2000 (has links)
Este trabalho apresenta estudos de usinabilidade de chapas MDF (Medium Density Fiberboard), tendo por objetivo principal efetuar uma análise do desempenho de corte em relação à qualidade da superfície usinada e à força específica de corte paralela necessária, a fim de se verificar a influência dos parâmetros estudados para operações de usinagem de acabamento e desbaste, respectivamente. No estudo para operação de acabamento verificou-se a influência da espessura de corte,velocidade de avanço e sentido de corte, em operação de fresamento cilíndrico periférico, sobre a rugosidade superficial da borda das chapas MDF. Uma fresadora vertical foi utilizada para gerar as superfícies, cuja rugosidade superficial foi medida por um perfilômetro de apalpamento. No estudo para operação de desbaste, a força específica de corte paralela foi avaliada em função da variação do ângulo de saída, da espessura de corte e da profundidade de corte, em operação de corte ortogonal. Para tanto, foram empregadas uma plaina limadora e uma célula de carga de extensômetros resistivos, conectada a um programa de aquisição e análise de dados. A partir da análise dos resultados obtidos, foi possível identificar a influência de cada parâmetro de corte empregado. / This work presents a MDF (Medium Density Fiberboard) machinability study aiming to carry out a cutting performance analysis regarding to surface quality and parallel specific cutting force, in order to verify the cutting parameters effect on the finishing and roughing machining operations, respectively. In the finishing study, it was verified the effect of the cutting thickness, cutting speed and direction of cutterhead rotation with relation to feed direction, in peripheral milling, on the MDF edges surface roughness. The surfaces were developed by a moulder, which roughness were measured by a stylus perfilometer. In the roughing study, the parallel specific cutting force was assessed in relation to the variation of the rake angle, cutting thickness and depth of cut, for the orthogonal cut. For this, it was used a planing machine and a resistance dynamometer, coupled in a data acquisition and analysis system. From the analysis of the obtained results, it was possible to identify the influence of each cutting parameter considered.
67

Avaliação in vitro da correlação do manchamento extrínseco de compósitos resinosos com grau de conversão, rugosidade, sorção e solubilidade / In vitro evaluation of the correlation among extrinsic staining, degree of conversion, roughness, sorption and solubility of resin composite

Anfe, Taciana Emília de Almeida 14 December 2012 (has links)
Nesta pesquisa in vitro verificou-se a possível correlação do manchamento superficial de resinas compostas com grau de conversão, rugosidade, sorção e solubilidade. Foram testados cinco compósitos: Charisma Opal, Filtek P90, GrandioSO, IPS Empress Direct e NDurance; todos da cor A2. Foram confeccionados 40 espécimes de cada material. Dez espécimes foram destinados aos testes de sorção e solubilidade, que foram divididos em dois grupos (n=5): Grupo 1 (com desidratação prévia) e Grupo 2 (sem desidratação prévia). Trinta espécimes foram destinados aos testes de grau de conversão, rugosidade e manchamento superficial; que foram divididos em dois grupos: Imediato e 24 horas. No grupo Imediato, a leitura do espectro para o cálculo do grau de conversão e a leitura da cor inicial (baseline) foram realizadas imediatamente após a confecção dos espécimes, que foram imersos nas bebidas corantes na sequência. No grupo 24 horas, os espécimes foram mantidos em água destilada a 37oC por 24 h. A leitura do espetro final para o cálculo do grau de conversão e a leitura da cor inicial (baseline) foram realizadas 24 h após a confecção dos espécimes, que só então foram imersos nas bebidas corantes. O polimento e a leitura da rugosidade foram realizados após a leitura do espectro e antes da imersão nas bebidas. Os espécimes foram divididos em três grupos (n=5): água destilada (controle), café e vinho tinto. A amostra foi mantida imersa nas bebidas por 7 dias, com temperatura em 37oC. A leitura da cor final foi realizada após esse período, em ambos os grupos. A diferença de cor foi calcula a partir da fórmula CIEDE2000. A análise estatística foi realizada e o teste de Pearson foi aplicado para a análise da correlação das propriedades testadas. De acordo com a metodologia utilizada neste estudo, não foi possível estabelecer correlação entre manchamento dos compósitos resinosos com grau de conversão, rugosidade superficial, sorção e solubilidade; não foi encontrada diferença no manchamento do grupo que foi submetido imediatamente às bebidas corantes com o grupo que foi submetido ao manchamento após 24 horas da sua confecção; o vinho tinto causou maior alteração de cor do que o café; e o comportamento dos compósitos na presença das bebidas corantes não foi semelhante. Além disso, não houve diferença significativa nas duas metodologias usadas para o teste de sorção e solubilidade. / This in vitro research verified the possible correlation of superficial staining of resin composites with degree of conversion, roughness, sorption and solubility. Five composites were tested: Charisma Opal, Filtek P90, GrandioSO, IPS Empress Direct and NDurance; shade A2. Forty specimens of each material were prepared. Ten specimens were reserved for sorption/solubility tests and were divided into 2 groups (n=5): Group 1 (with previous dehydration) and Group 2 (without previous dehydration). Thirty specimens were reserved for degree of conversion, roughness and staining tests; which were divided into 2 groups: Immediate and 24 hours. In Immediate group, degree of conversion and initial color measurement (baseline) were calculated immediately after sample preparation, which was immersed in coloring beverages. In 24 hours group, specimens were maintained in distilled water at 37oC for 24 h. Initial color measurement (baseline) and degree of conversion were calculated 24 h after sample preparation. Polishing and roughness measurement were made before the immersion of specimens in beverages. Sample was divided into 3 groups (n=5): distilled water (control), coffee and red wine. The specimens were maintained immersed for staining during 7 days at 37oC. Final color measurement was made after this period, in both groups. Color difference was calculated based on CIEDE2000 formula. Statistical analysis was performed and Pearson test was applied to analyze correlation between the properties tested. According to the methodology used in this research, it was not possible to establish correlation between composite staining and degree of conversion, roughness, sorption and solubility; it was not found any difference between Immediate and 24 hours groups; staining caused by red wine were more intense than coffee; the composites behavior in staining was not similar. Despite of this result, there was no significant difference between the sorption/solubility methods tested.
68

Análise da estrutura energética e da dinâmica de portadores fotogerados em heteroestruturas semicondutoras de InGaAs/InP e AlGaAs/GaAs / Analyses of the energy structure and dynamics of photogenerated carriers in InGaAs/InP and GaAs/AlGaAs semiconductor heterostructures

Patricio, Marco Antonio Tito 21 November 2018 (has links)
Esta tese apresenta um estudo experimental em sistemas eletrônicos multicamadas formados em diversas heteroestruturas semicondutoras de alta qualidade crescidas por epitaxia de feixes moleculares. Especificamente, poços quânticos isolados baseados em InGaAs/InP e super-redes baseadas em GaAs/AlGaAs foram caraterizados por meio de medidas de fotoluminescência (PL) em função da temperatura, potência de excitação e do campo magnético. O estudo de efeitos na dinâmica de processos de recombinação destes sistemas eletrônicos é a base principal deste trabalho. Além disso, exploramos os efeitos da desordem sobre os processos de recombinação e demonstramos que o espalhamento por rugosidade interfacial é responsável pela resposta óptica destes sistemas. Nas amostras de InGaAs/InP com maior largura do espaçador observamos um novo efeito, o tempo de recombinação Auger aumenta notavelmente com a potência de excitação. Atribuímos este novo efeito à distribuição de elétrons fotoexcitados em diferentes vales da banda de condução. E em amostras de menor largura do espaçador, o relaxamento da regra de seleção do momento induzido pela desordem faz que o tempo de recombinação Auger diminua com o aumento da potência. Por outro lado, nas amostras de GaAs/AlGaAs, evidenciamos que a desordem gerada pela rugosidade interfacial afeta consideravelmente o transporte dos elétrons da banda de condução, e em poços quânticos de largura apropriada resulta em uma transição metal-isolante. A borda de mobilidade Ec, energia crítica que separa os estados estendidos dos estados localizados, foi determinada a partir das medidas do tempo de recombinação em função da energia de emissão de PL. Para uma desordem crítica, a Ec mostra uma interseção com a energia do nível de Fermi, a qual corresponde à transição metal-isolante. Além disso, realizamos medidas de PL resolvida no tempo em função do campo magnético. Observamos que a redistribuição espacial de elétrons causada pelo campo magnético afeta os tempos de recombinação. Nas amostras metálicas, os resultados mostraram deslocamento da Ec para altas energias, devido à quantização da energia dos elétrons provocada pelo campo magnético. No entanto, nas amostras isolantes, o campo magnético foi responsável pelo relaxamento significativo da regra de seleção do momento, que aumenta a probabilidade de recombinação dos elétrons localizados com os buracos fotoexcitados da banda de valência e, por consequência, diminui o tempo de recombinação. / This thesis presents an experimental study in multilayer electronic systems formed in several high quality semiconductor heterostructures grown by molecular beam epitaxy. Specifically, GaAs/AlGaAs based superlattices and isolated quantum wells based on InGaAs/InP were characterized by photoluminescence (PL) measurements as a function of temperature, pump power and magnetic field. The study of effects on the dynamics of the recombination processes of these electronic systems is the principal goal of this work. In addition, we explore the effects of the disorder on the recombination processes and show that the interfacial roughness scattering is responsible for the optical response in these systems. In the small spacer InGaAs/InP samples, we observed a new effect, the Auger recombination time becomes larger with the increasing the pump power. We propose that the distribution of photoexcited electrons over different conduction band valleys might account for this effect. In large spacer quantum wells, the non-radiative recombination time is reduced with the increasing pump power, as a consequence the disorder-induced relaxation of the momentum rule. On the other hand, in GaAs/AlGaAs samples, we showed that the disorder generated by interfacial roughness considerably affects transport of the conduction band electrons and at appropriate quantum wells width results in a metal-to-insulator transition. The mobility edge energy Ec was determined from the measurements of the recombination time as a function of energy allowed. At a critical disorder, the mobility edge energy demonstrates intersection with the Fermi level energy which correspond to the metal-insulator transition. In addition, we perform time-resolved PL measurements as a function of the magnetic field. We observed that the spatial distribution of electrons caused by the magnetic field influence on the recombination time. In the metallic samples was observed a shift of the mobility edge to higher energy due to the magnetic field quantization of conduction band electron energy. However, in the insulating samples, the magnetic field was responsible to cause a significant relaxation of the momentum selection rule which enhances the probability of recombination of the localized electrons with the photoexcited holes of the valence band, and consequently the recombination time is reduced.
69

Avaliação da alteração de rugosidade de superfície e dispersão de íons de ligas metálicas odontológicas submetidas a ensaio de tribocorrosão experimental / Evaluation of changes in surface roughness and ion release from dental casting alloys after an experimental tribocorrosion process

Pupim, Denise 14 January 2016 (has links)
Este estudo teve como objetivo avaliar a alteração da rugosidade superficial e a dispersão de íons para o meio após tribocorrosão experimental das ligas CoCrMo, NiCr e NiCrTi, comercialmente utilizadas na fabricação de próteses odontológicas, utilizando solução de saliva artificial (Fusayama) como eletrólito com valores de pH 3,0; 6,5 e 9,0. Foram fundidas 15 amostras de cada liga (&Oslash;13x2mm) por chama e 15 por máquina de fundição com atmosfera inerte de argônio, sendo cinco amostras para cada pH analisado. A tribocorrosão experimental foi realizada na configuração esfera sobre superfície, utilizando esfera de zircônia (&Oslash;10mm), em equipamento de ciclagem vertical, simulando o movimento do ciclo mastigatório, com aplicação de 5N de carga e monitoramento do potencial de circuito aberto (OCP). O sistema operou a velocidade de 60 ciclos por minuto, totalizando 7500 ciclos após 15 minutos de ensaio, equivalente ao tempo de contato dental diário. Foi utilizada saliva artificial de pH 3,0; 6,5 e 9,0 e leituras de rugosidade de superfície foram realizadas antes e após os ensaios de tribocorrosão experimental em microscópio confocal a laser. A saliva utilizada foi armazenada em tubos de Falcon DNA-free e submetida à quantificação da dispersão de íons metálicos para a solução, por meio de análise de ICP-MS. O comportamento das ligas em contato com a esfera de zircônia durante o ensaio de tribocorrosão experimental realizado em potencial de circuito aberto foi alterado em função do pH do meio (P<0,001) e da técnica de fundição utilizada (P<0,001). Todas as amostras apresentaram tendência à repassivação após a remoção do contato com a esfera, indicando formação de novo filme protetor na superfície da liga. A liberação de íons foi maior nas amostras fundidas por chama e em contato com pH 3,0 (ácido), sendo o analito níquel liberado em maior concentração (P=0,010). Entretanto, os valores encontrados estão abaixo dos limites indicados como causadores de citotoxicidade e alterações celulares. Os resultados indicam que as amostras fundidas por chama apresentaram rugosidade de superfície estatisticamente maior que as fundidas por plasma (P=0,042), sendo observado nessas amostras a presença de defeitos na superfície e possíveis falhas de fundição que favorecem o processo corrosivo. O pH da saliva e a técnica de fundição exerceram influência sobre o comportamento de repassivação das ligas, rugosidade de superfície e quantidade de íons liberada para o meio, sendo os melhores resultados encontrados quando a técnica de fundição por plasma foi utilizada. / The aim of this study was to evaluate the changes in surface roughness and ions release to the environment after experimental tribocorrosion of CoCrMo, NiCr and NiCrTi alloys, commercially applied in dental prosthesis, using artificial saliva solution (Fusayama) as electrolyte with different levels of pH (3.0; 6.5 and 9.0). Fifteen samples were casted by flame from each alloy (&Oslash;13x2mm) and 15 by plasma in a casting machine with an inert atmosphere (argon), five samples for each pH analyzed. The experimental tribocorrosion was performed in a ball-on-flat configuration, using a zirconia ball (&Oslash;10mm) in vertical cycling equipment, simulating the masticatory cycle movement, applying 5N of load and recording the open circuit potential (OCP). The system operated at 60 cycles per minute, a total of 7500 cycles after 15 minutes, corresponding to the daily tooth contact. Artificial saliva at pH 3.0; 6.5 and 9.0 was used and surface roughness measurements were performed before and after the experimental tribocorrosion tests in a laser confocal microscope. After the tests, the saliva was stored in a DNA-free Falcon tubes and subjected to measurement of the ion release to the solution by means of ICP-MS analysis. The behavior of the alloys in contact with the zirconia ball during the experimental tribocorrosion performed in open circuit potential changed according to the pH (P<0.001) and the casting technique (P<0.001). All samples trended to repassivate when the ball contact was removed, indicating new formation of the protective film on alloy surface. The ion release was higher in the samples casted by flame and in contact with pH 3.0 (acid), nickel analyte being released in a higher concentration (P=0.010). However, the values found are below the limits specified to induce cytotoxicity and cellular changes. The results reflected that the samples casted by flame presented surface roughness statistically greater than those casted by plasma (P=0.042) and it was observed in these samples the presence of surface defects and possible casting flaws that enhance the corrosion process. The pH of the saliva and the casting technique presented influence on the repassivation behavior of the alloys, surface roughness and quantity of ions released into the environment, where the best results were found when the plasma casting technique was used.
70

Avaliação clínica do efeito de dentifrícios clareadores na cor e rugosidade do esmalte dental e compósitos odontológicos / Clinical evaluation of color and surface roughness of dental enamel and dental composites submitted to brushing with whitening toothpaste

Lourenço de Moraes Rego Roselino 11 August 2015 (has links)
Os objetivos deste estudo foram avaliar clinicamente a alteração de cor e de rugosidade de superfície do esmalte dental e de compósitos odontológicos, submetidos à escovação com dentifrícios clareadores e a ação deles sobre a degradação das pontas das cerdas da escova dental. Foram obtidos 30 corpos-de-prova (6mm de diâmetro X 2mm de espessura) de cada compósito (Z250 e Z350, 3M ESPE e Tetric N-Ceram, Ivoclar Vivadent). Em seguida, estes foram aleatoriamente fixados na face vestibular dos primeiros molares superiores (direito e esquerdo) e de um segundo molar superior (direito ou esquerdo) de 30 participantes selecionados para o estudo, de acordo com os critérios de inclusão determinados. Após a fixação dos espécimes, os participantes receberam escovas de dentes (Oral B Classic, Procter & Gamble) e dentifrício convencional (Sorriso Dentes Brancos, Colgate-Palmolive) e foram orientados a utilizar esses produtos durante 7 dias (período pré-experimental) após o qual foram realizadas as leituras iniciais de cor (Easyshade, VITA) e de rugosidade de superfície (Rugosímetro Surfcorder SE 1700, Kosakalab) das amostras e também do esmalte dental de um dos incisivos centrais superiores dos participantes. Para as leituras de rugosidade foi realizada moldagem (Express, 3M ESPE) do incisivo central superior e dos corpos-de-prova fixados para posterior obtenção de modelos com resina de poliuretano (Axon F16, Abcol) para confecção de réplicas, sobre as quais foram realizadas as leituras. Após as leituras iniciais, os participantes foram separados em 3 grupos (n=10), conforme o dentifrício clareador utilizado: Grupo 1) Dentifrício controle (Sorriso Dentes Brancos); Grupo 2) Dentifrício clareador (Colgate Luminous White, Colgate-Palmolive); e Grupo 3) Dentifrício clareador de ação rápida (Close up White Now, Unilever). As cerdas das escovas dentais utilizadas pelos participantes foram analisadas por MEV (Microscópio XL30 Field Emission Gun, Philips), em duas regiões da escova: periférica e central. Os períodos de análise da ação dos dentifrícios clareadores foram, 7, 30 e 90 dias. Os valores das medições (antes e após os períodos de testes) foram analisados estatisticamente (3-way-ANOVA, medidas repetidas, Tukey, p<0,05) e os resultados demonstraram que não houve alteração de cor significativa dos substratos analisados independentemente do tipo de dentifrício utilizado, mas o tempo de utilização de um dentifrício sobre os compósitos foi significante para a alteração de cor. Não houve alteração de rugosidade de superfície do esmalte dental, independente do dentifrício utilizado. A alteração de rugosidade de superfície dos compósitos é material dependente, mas o tempo de escovação com esses dentifrícios não interfere nessa propriedade. Quanto maior o tempo de escovação, maior o desgaste da ponta das cerdas da escova, independente do dentifrício utilizado e da região a que ela pertence. Conclui-se que a alteração de cor e de rugosidade de superfície dos compósitos é material-dependente e tempo-dependente para a alteração de cor e para degradação das cerdas da escova. / The aims of this study were to clinically evaluated the color change and the surface roughness of enamel and dental composites submitted to brushing with whitening toothpaste and the their action over the degradation of the tips of the bristles of the toothbrush. 30 specimens were obtained (6 mm diameter X 2mm thick) of each composite (Z250 and Z350, 3M ESPE and Tetric N-Ceram, Ivoclar Vivadent). Then, the specimens were randomly bonded on the maxillary first molars buccal surfaces (right and left sides) and the one maxillary second molar (right or left sides) of 30 participants, which were selected for the study according to inclusion criteria. After specimens bonding, participants received toothbrush (Oral B Classic, Procter & Gamble) and non whitening toothpaste (Sorriso Dentes Brancos, Colgate-Palmolive) and also they were instructed to use these products for 7 days (pre-trial). After that, were realized the initial color (Easyshade, VITA) and surface roughness (Roughness Surfcorder SE 1700, KosakaLab) readings of specimens and of the enamel of the maxillary central incisors of the participants. For surface roughness readings was performed molding (Express, 3M ESPE) of the maxillary central incisor and of the specimens fixed to be retrieved later of the models with polyurethane resin (Axon F16, Abcol). Then in these replicas were made surface roughness readings. After baseline measurements, participants were divided into 3 groups (n=10), according to the whitening toothpaste used: Group 1) Control toothpaste (Sorriso Dentes Brancos); Group 2) Whitening toothpaste (Colgate Luminous White, Colgate-Palmolive); and Group 3) Whitening toothpaste with fast action (Close up White Now, Unilever). The bristles of toothbrushes used by the participants were analyzed by SEM (Field Emission Gun Microscope XL30, Philips) in two regions of the brush: peripheral and central. The periods of action analysis of whitening toothpaste were 7, 30 and 90 days. The measured values (before and after the testing periods) were statistically analyzed (3-way ANOVA, repeated measures, Tukey, p <0.05) and the results showed no significant color change of the substrates analyzed independently of the type toothpaste used, but the time of use of a dentifrice over the composites was significant for the color change. There was no surface roughness change enamel independently of the toothpaste used. The surface roughness change of composites is dependent on material, but the time of brushing with these toothpaste does not interfere in this property. The longer the time of brushing, the greater the degradation in the tips of the bristles of the toothbrush independently of the toothpaste used and the region to which it belongs. It is conclude that the color change and surface roughness of the composites is material-dependent and time-dependent to color change and to degradation of the brush bristles.

Page generated in 0.0324 seconds